SUMMARY FAN DATA SHEET

Nuaire Limited, Western Industrial Estate, Caerphilly, CF83 1NA, United Kingdom. email:info@nuaire.co.uk
UK Commercial Enquiries T:029 2085 8200 UK Residential Enquiries T:029 2085 8500 International Enquiries T:+44.29 2085 8497
Whilst the information given on this data sheet is fan specific, it is in summary and reference to the product selection catalogue and installation & maintenance documents is recommended.
This data sheet produced on 19 Oct 2015 16:23 using software version 3.1.15 - 14-November-2014

Technical Data

Specification

Axus Long Case. Class F ambient, 400V 3ph 50Hz TEFC


IE2 IP55, with a PTC. Aluminium impeller. Galvanised
steel case.

Axus 630mm diameter long cased circular axial flow fan manufactured
from pre-galvanised mild steel. Fan incorporates inlet and outlet
flanges with pre-drilled bolt holes and an external standard safe area
terminal box. Wiring provided to case. Impeller blades manufactured
from aluminium mounted in an aluminium hub as standard. The motor
is 400V three phase, single speed, totally enclosed fan-cooled,
protected to IP55, foot mounted, class F insulated and has sealed for
life bearings. The motor is fitted with a PTC. Motor efficiency is IE2.
NOTE: This unit cannot be inverter speed controlled.

Fan Code:
Installation Manual Links:
Required Duty:
Actual Duty:
Actual at Required Flow:
Motor Efficiency:
Fan Total Efficiency:
Fan Input Power:
Maximum Fan Input Power:
Motor Input Power:
Specific Fan Power:
Nominal Fan Speed:
Electrical Supply:
Nominal Motor Rating:
Motor Current:
Motor Current:
Overload Setting:
Starting currents are nominal.
Motor Frame Size:
Blade Angle:
Max. Operating Temp.:
Weight:

AX63F-42A3-07
671220
634 l/s @ 250 Pa
676 l/s @ 284 Pa
634 l/s @ 286 Pa
79 %
33 %
0.583 kW
0.696 kW
0.733 kW
1.1 W/(l/s)
4 Pole 1,410 RPM
400 V 3 Phase 50 Hz
0.75 kW
flc: 2.33 A
sc: 13.98 A
2.563 A
80
30
55C
40 kg

Sound Data
Acoustic perfomance to BS848 Part 2.2 and AMCA 300.
Breakout Noise (dBA): 52 dBA @ 3m
Breakout level is spherical. For hemi-spherical add 3 dBA.
Sound Power Levels re 1 pWatts (Hz):
Hz
63 125 250 500 1k
2k
4k
8k
Induct Inlet
80 88 86 83 79 75 71 66
Induct Outlet
81 90 93 92 83 78 72 67
Open Inlet
72 84 84 83 79 75 71 66
Open Outlet
73 86 90 92 83 78 72 67
Breakout
62 69 79 69 57 63 60 48
Noise calculated at actual duty of fan.
Values shown are for inlet Lw and outlet Lw sound power levels for:
Installation Type D: ducted inlet, ducted outlet. Ratings include the
effects of duct end correction.

NAV2
Resilient rubber anti-vibration mountings, supplied as a set of 4.

CMB63
The mounting brackets are manufactured from heavy gauge
galvanised steel and supplied in pairs.

CMF63
The matching flanges are manufactured from galvanised steel and are
supplied individually.

CFC63
Circular flexible connector without flanges. Flexible duct material is
flameproof and resistance to heat up to 132C, chemicals, ozone, oil
and grease. The material is airtight, waterproof and tested to BS476
Part 7. Supplied complete with fixing straps.

Selected Ancillaries
1 x NAV2
1 x CMB63
2 x CMF63
2 x CFC63

Anti-vibration mounting kit


Mounting bracket (pair)
Matching flange
Flexible connector

SUMMARY FAN DATA SHEET - PERFORMANCE


Nuaire Limited, Western Industrial Estate, Caerphilly, CF83 1NA, United Kingdom. email:info@nuaire.co.uk
UK Commercial Enquiries T:029 2085 8200 UK Residential Enquiries T:029 2085 8500 International Enquiries T:+44.29 2085 8497
Whilst the information given on this data sheet is fan specific, it is in summary and reference to the product selection catalogue and installation & maintenance documents is recommended.
This data sheet produced on 19 Oct 2015 16:23 using software version 3.1.15 - 14-November-2014

Technical Data
Axus Long Case. Class F ambient, 400V 3ph 50Hz TEFC
IE2 IP55, with a PTC. Aluminium impeller. Galvanised
steel case.
Fan Code:
AX63F-42A3-07
Required Duty:
Actual Duty:
Actual at Required Flow:
Motor Efficiency:
Fan Total Efficiency:
Fan Input Power:
Maximum Fan Input Power:
Motor Input Power:
Specific Fan Power:

634 l/s @ 250 Pa


676 l/s @ 284 Pa
634 l/s @ 286 Pa
79 %
33 %
0.583 kW
0.696 kW
0.733 kW
1.1 W/(l/s)

Fan Efficiency %

Performance Curve
80%
60%
40%
20%

0.9

Fan / Motor Input Power (kW)

0.85
0.8
0.75
0.7
0.65
0.6
0.55
300

250

200

150

Static Pressure (Pa)

100

50

0
500
Volume Flow Rate (l/s)

1k

1500

2k

2500

3k

3500

SUMMARY FAN DATA SHEET - DRAWINGS


Nuaire Limited, Western Industrial Estate, Caerphilly, CF83 1NA, United Kingdom. email:info@nuaire.co.uk
UK Commercial Enquiries T:029 2085 8200 UK Residential Enquiries T:029 2085 8500 International Enquiries T:+44.29 2085 8497
Whilst the information given on this data sheet is fan specific, it is in summary and reference to the product selection catalogue and installation & maintenance documents is recommended.
This data sheet produced on 19 Oct 2015 16:23 using software version 3.1.15 - 14-November-2014

Technical Data
Axus Long Case. Class F ambient, 400V 3ph 50Hz TEFC
IE2 IP55, with a PTC. Aluminium impeller. Galvanised
steel case.
Fan Code:

AX63F-42A3-07

630
740
480
430
360
The drawing is for dimensional purposes only. Dimensions in mm.

kg

12

12

690

500

550

40

Ancillary Dimensions
NAV2 - Anti-vibration mounting kit
B=45 C=75 mm

CFC63 - Flexible connector


B=150 mm Weight: 2 kg

CMB63 - Mounting bracket (pair)


G=430 H=500 mm Weight: 6 kg

CMF63 - Matching flange


A=65 mm Weight: 4 kg