ARD water can be classified as under saturated water that have tendency to remove existing calcium
carbonate in the wash water pan. ARD water also has tendency to form scaling but has a slightly potential
to occur corrosion in wash water pan. Following table shows the Langerier Index of ARD water.
pH Saturation
LSI
Mean
7.70
-044
Stdev
0.06
0.24
Median
7.69
-047
Min
7.61
0.83
Max
7.83
0.07
Recommendation
Check level sensor in each tank and ensure in induce lime at 2TK244 reach pH level 7.6 for the goal
to utilize ARD water as column wash water.
Check level sensor on 2TK-246 to monitor the ARD water and lime availability.
Exhibit-1
pH ARD water monitoring result
Day
Day-1
Day-2
Day-3
Day-4
Day-5
Day-6
Sampler
(4hourly)
2TK-244
2TK-245
2TK-246
7,03
7,57
8,00
7,02
7,57
8,01
Day
Neutralization Tank
Day-7
Sampler
(4-hourly)
Neutralization Tank
2TK-244
2TK-245
2TK-246
6,49
6,75
7,60
6,49
6,62
7,52
7,04
7,57
8,01
6,47
6,66
7,51
6,97
7,60
8,02
6,47
6,49
7,50
6,96
7,62
8,02
6,51
6,58
7,49
6,72
8,03
8,02
6,52
6,66
7,50
6,68
8,28
8,01
6,54
6,66
7,51
6,73
8,92
9,27
6,55
6,65
7,51
6,76
9,78
10,00
6,54
6,58
7,51
6,93
8,47
9,39
6,54
6,55
7,85
6,95
8,32
8,85
6,66
6,98
8,03
6,90
8,17
8,33
6,72
7,18
7,52
6,88
8,23
8,37
6,74
7,02
6,86
6,90
8,48
8,63
6,51
7,05
7,30
Day-8
Day-9
6,99
8,50
8,71
6,48
7,16
7,59
6,90
8,36
8,96
6,48
7,04
7,49
6,96
8,19
9,14
6,48
7,00
7,50
7,03
7,98
9,13
6,48
6,97
7,51
Day10
7,14
8,15
8,94
6,54
6,84
7,51
7,18
8,17
8,47
6,55
6,86
7,50
6,99
7,86
8,48
6,51
6,83
7,50
7,02
7,59
8,06
6,65
6,85
7,49
6,75
7,59
8,03
6,69
6,83
7,48
6,71
7,60
8,05
6,67
6,71
7,37
6,64
7,59
8,06
6,66
6,69
7,32
6,63
7,58
8,04
6,59
6,69
6,99
Day-11
6,62
7,58
8,04
6,59
6,73
6,89
6,66
7,59
8,04
6,50
7,13
7,27
6,70
7,57
8,04
6,46
7,30
7,64
6,58
7,57
8,04
6,46
7,76
8,01
Day12
6,58
7,57
8,05
6,44
7,88
7,99
6,59
7,57
8,05
6,82
7,79
7,88
6,54
7,58
8,04
7,12
7,60
7,77
6,52
7,58
8,04
6,77
6,98
7,55
6,53
7,59
8,04
6,60
6,99
7,48
6,58
7,74
8,04
6,67
7,14
7,35
Exhibit-2
Flowsheet current ARD water treatment