Specifications
Cable and technical specifications for Catalyst 4500 E-series switches are provided in the following
sections:
Note
Specifications for individual switching modules and supervisor engines, including power consumption
and thermal output information, are in the Catalyst 4500 Series Module Installation Guide, available
online at:
http://www.cisco.com/en/US/docs/switches/lan/catalyst4500/hardware/module/guide/mod_inst.html
A-1
Appendix A
Specifications
Item
Specification
Environmental
Temperature,
ambient operating
32 to 104F (0 to 40C)
Temperature,
ambient nonoperating and storage
Switching Components
Backplane
Port density
Inline power
Acoustic Data
Physical Characteristics
Dimensions (H x W x D)
Weight
Airflow
Switch
Right to left
Power supply
Front to back
Power
PoE supplied
48 VDC
12 VDC
3.3 VDC
A-2
OL-13972-02
Appendix A
Specifications
Catalyst 4506-E Switch Specifications
Table A-1
Item
Specification
Redundancy
Supervisor engine
no
Power supply
1+1
Item
Specification
Environmental
32 to 104F (0 to 40C)
40 to 167F (40 to 75C)
Switching Components
Backplane
Port density
Inline power
Acoustic Data
Physical Characteristics
Dimensions (H x W x D)
Weight
Airflow
Switch
Right to left
Power supply
Front to back
A-3
Appendix A
Specifications
Table A-2
Item
Specification
Power
PoE supplied
48 VDC
12 VDC
3.3 VDC
Redundancy
Supervisor engine
no
Power supply
1+1
Item
Specification
Environmental
Temperature,
ambient operating
ambient nonoperating and storage
32 to 104F (0 to 40C)
40 to 167F (40 to 75C)
Switching Components
Backplane
Port density
Inline power
Acoustic Data
A-4
OL-13972-02
Appendix A
Specifications
Catalyst 4510R-E Switch Specifications
Table A-3
Item
Specification
Physical Characteristics
Dimensions (H x W x D)
Weight
Airflow
Switch
Right to left
Power supply
Front to back
Power
PoE supplied
48 VDC
12 VDC
3.3 VDC
Redundancy
Supervisor engine
yes
Power supply
1+1
Item
Specification
Environmental
Temperature,
ambient operating
ambient nonoperating and storage
32 to 104F (0 to 40C)
40 to 167F (40 to 75C)
A-5
Appendix A
Specifications
Table A-4
Item
Specification
Switching Components
Backplane
Port density
Inline power
Acoustic Data
Physical Characteristics
Dimensions (H x W x D)
Weight
Airflow
Switch
Right to left
Power supply
Front to back
Power
PoE supplied
48 VDC
12 VDC
3.3 VDC
Redundancy
Supervisor engine
yes
Power supply
1+1
A-6
OL-13972-02
Appendix A
Specifications
Catalyst 4510R-E Switch Specifications
Note
All Catalyst 4500 series switch AC-input power supplies require single-phase source AC. The source AC
can be out of phase between multiple power supplies or multiple AC-power plugs on the same power
supply because all AC power supply inputs are isolated. Each chassis power supply should have its own
dedicated branch circuit: 15 A or 20 A for North America and circuits sized to local and national codes
for International locations.
For more information about power management and planning, refer to the Environmental Monitoring
and Power Management chapter in the Catalyst 4500 Series Switch Cisco IOS Software Configuration
Guide version appropriate for your software.
1000 W AC
Table A-5
Item
Specification
Not supported1
AC-input type
AC-input voltage
AC-input current
1.32 KVA
AC-input frequency
20 ms minimum
943 BTUs/hr
LEDs
Power Cords
1. A Catalyst 4503 with a Catalyst 4500 series Supervisor Engine II-Plus TS and a 1000W power supply will be able to provide
158.4 W of Power over Ethernet to ports on the supervisor engine. Switching modules in other slots will not be able to provide PoE.
A-7
Appendix A
Specifications
1300 W AC
Table A-6
Item
Specification
Supported, up to 800 W
(211 Cisco phones in combined mode)
AC-input type
AC-input voltage
AC-input current
AC-input frequency
1.76 KVA
1300 W maximum
1050 W+ 40 W redundant mode (Data)
1667 W maximum in combined mode (Data)
800 W maximum each in redundant mode (PoE)
1333 W maximum in combined mode (PoE)
1568 BTUs/hr
20 ms minimum
LEDs
Power Cords
A-8
OL-13972-02
Appendix A
Specifications
Catalyst 4510R-E Switch Specifications
1400 W AC
Table A-7
Item
Specification
Not supported1
AC-input type
AC-input voltage
AC-input current
AC-input frequency
1.76 KVA
2473 W maximum
1360 W+ 40 W redundant mode (Data)
1048 BTUs/hr
20 ms minimum
LEDs
Power Cords
1. A Catalyst 4503-E with a Catalyst 4500 series Supervisor Engine II-Plus TS and a 1400W AC power supply provides 158.4 W
of PoE to ports on the supervisor engine. Switching modules in other slots will not be able to provide PoE.
A-9
Appendix A
Specifications
1400 W DC
Caution
Do not mix the 1400 W DC power supply with any other power supply, even for a hot swap or other
short-term emergency. Doing so can seriously damage your switch.
The 1400W DC Input power supply may be used with the Catalyst 4500 Series AC Power Shelf.
Documentation for the Catalyst 4500 Series AC Power Shelf is at:
http://www.cisco.com/en/US/docs/switches/lan/catalyst4500/hardware/configuration/notes/
78_15068.html
Table A-8
Item
Specification
DC-input voltage
DC-input current
Input power
Current draw At 40.5 V (min voltage)
Current draw at 72 V (max voltage)
Max heat dissipation at 1866 W
1.87 (data)
9.15 (data and voice)
A-10
OL-13972-02
Appendix A
Specifications
Catalyst 4510R-E Switch Specifications
Table A-8
Item
Specification
4 ms
Maximum draw
475 W
Maximum input
633 W
2160 BTUs
850 W
Maximum input
1133 W
3515 BTUs
1080 W
1440 W
20 A
4910 BTUs
Table A-9
Item
Specification
Not supported
DC-input voltage
DC-input current
A-11
Appendix A
Specifications
Table A-9
Item
Specification
Input power
Current draw At 40.5 V (min voltage)
Current draw at 72 V (max voltage)
Max heat dissipation at 1400 W
8 ms
1269 BTUs/hr
A-12
OL-13972-02
Appendix A
Specifications
Catalyst 4510R-E Switch Specifications
Table A-9
Item
Specification
Maximum draw
475 W
Maximum input
2078 BTUs
850 W
Maximum input
Current draw at 40.5 V (min voltage) 26.6 A total / # of modules = A per module
Current draw at 72 V (max voltage) 15 A total / # of modules = A per module
Max heat dissipation at 1076 W
3671 BTUs
1080 W
Current draw at 40.5 V (min voltage) 33.75 A total / # of modules = A per module
Current draw at 72 V (max voltage)
4665 BTUs
Output for this power supply depends on how power is provided and and configured, refer to the 1400
W DC Triple-input Power Supply Operational Modes section on page 1-30 for more detail.
Table A-10
Input
Mode
Input
Number
Input Configuration
1 x 12.5 A
2 or 3
1 x 15 A
1, 2 or 3
1 x 12.5 A and
1 x 15 A
2, 3
2 x 15 A
1, 2, 3
1 x 12.5 A and
2 x 15 A
A-13
Appendix A
Specifications
Power output also depends on whether two supplies are used, and whether they are in redundant or
combined mode. Table A-11 provides a matrix of possible outputs in combined mode dependingon the
power provided to the supply.
Table A-11
PS2 input
PS2 input 1 2 or 3
PS2 input
1 and
(2 or 3)
PS2 input
2 and 3
PS2 input
1 and 2 and 3
PS1 input 1
824 W
907 W
1320 W
1400 W
1700 W
PS1 input 2 or 3
907 W
990 W
1400 W
1450 W
1750 W
1320 W
1400 W
1700 W
1750 W
1900 W
PS1 input
2 and 3
1400 W
1450 W
1750 W
1820 W
2130 W
PS1 input
1 and 2 and 3
1700 W
1750 W
1900 W
2130 W
2450 W
A-14
OL-13972-02
Appendix A
Specifications
Catalyst 4510R-E Switch Specifications
2800 W AC
Table A-12
Item
Specification
Supported, up to 1400 W
(240 Cisco phones in combined mode)
AC-input type
AC-input voltage
AC-input current
AC-input frequency
3.52 KVA
2800 W maximum
12 V @113.3 A, 3.3 V @12.1 A (Data)
50 V @28 A (PoE)
1360 W+ 40 W redundant mode (Data)
2473 W maximum in combined mode (Data)
1400 W maximum each in redundant mode (PoE)
2333 W maximum in combined mode (PoE)
2387 BTUs/hr.
20 ms minimum
LEDs
Power Cords
A-15
Appendix A
Specifications
4200 W AC
Table A-13
Item
Specification
Supported, up to 4200 W
AC-input type
AC-input voltage
Note
AC-input current
AC-input frequency
5.25 KVA
3583 BTUs/hr.
20 ms minimum
LEDs
Power Cords
The 4200 W AC power supply should not be used in mixed-voltage configurations. All the inputs in a
chassis must be at the same voltage (110 VAC or 220 VAC).
Table A-14 shows the wattage output possible from a 4200W power supply in redundant mode. In
redundant mode, two power supplies must have identical inputs and all inputs must be at the same
voltage. If the input voltages are mismatched, choose the value matching the weaker of the two power
supplies.
A-16
OL-13972-02
Appendix A
Specifications
Catalyst 4510R-E Switch Specifications
Table A-14
12V
3.3V
-50V
Total
660 W
40 W
700 W
1050 W
1360 W
40 W
1850 W
2100 W
1360 W
40 W
3700 W
4200 W
Table A-15 shows the maximum output wattage with two 4200 W power supplies in combined mode.
Table A-15
W @ 12 V
W @3.3 V
W @ -50 V
Maximum (W)
1200 W
40 W
1320 W
1870 W
One 110 VAC input to one PS, two 110 VAC 1800 W
inputs to the other PS
40 W
2000 W
2730 W
2200 W
40 W
3100 W
3800 W
2200 W
40 W
3100 W
3800 W
Two 220 VAC inputs to one PS, one 220 VAC 2200 W
input to the other PS
40 W
4700 W
5500 W
40 W
6200 W
7600 W
2200 W
A-17
Appendix A
Specifications
6000 W AC
Table A-16 shows the specifications for the 6000 W power supplies.
Table A-16
Item
Specification
Supported, up to 4800 W
AC-input type
AC-input voltage
Note
AC-input current
AC-input frequency
2,720 BTUs/hr.
20 ms minimum
LEDs
Power Cords
The 6000 W AC power supply should not be used in mixed-voltage configurations. All the inputs in a
chassis must be at the same voltage (110 VAC or 220 VAC).
A-18
OL-13972-02
Appendix A
Specifications
Catalyst 4510R-E Switch Specifications
Table A-17 shows the wattage output possible from a 6000 W power supply in redundant mode. In
redundant mode, two power supplies must have identical inputs and all inputs must be at the same
voltage. If the input voltages are mismatched, choose the value matching the weaker of the two power
supplies.
Table A-17
12V
3.3V
-50V
Total
850 W
40 W
922 W
1050 W
1700 W
40 W
1850 W
2100 W
2200 W
40 W
2400 W
3000 W
2200 W
40 W
4600 W
6000 W
Table A-18 shows the maximum output wattage with two 6000 W power supplies in combined mode.
Table A-18
W @ 12 V
W @3.3 V
W @ -50 V
Maximum (W)
1400 W
40 W
1670W
1710 W
2360 W
40 W
2560W
2800 W
3090 W
40 W
3360W
3700 W
4000 W
40 W
4360W
5400 W
4000 W
40 W
6600W
6200 W
4000 W
40 W
8700W
10900 W
A-19
Appendix A
Specifications
AC or
DC
Input
Power
(W)
DC
Output
Power
(W)
Reset
Mode
(W)
Input
Current
Heat
Dissipation at 90
VAC (A)
(BTU/Hr)
Input
Current
at 120
VAC (A)
Input
Current
at 180
VAC (A)
Input
Current
at 240
VAC (A)
Catalyst 4503-E
chassis (with fans)
80
60
273
0.89
0.67
0.44
0.33
Catalyst 4506- E
chassis (with fans)
160
120
546
1.78
1.33
0.89
0.67
Catalyst 4507R-E
chassis (with fans)
180
135
614
2.00
1.50
1.00
0.75
Catalyst 4510R-E
chassis (with fans)
267
200
909
2.96
2.22
1.48
1.11
WS-X45-SUP6-E
347
200
200
1182
3.85
2.89
1.93
1.44
WS-X45-SUP6L-E
267
200
80
909
2.96
2.22
1.48
1.11
WS-X45-SUP6-E
(standby)
247
185
135
841
2.74
2.06
1.37
1.03
WS-X45-SUP6L-E
(standby)
200
165
80
750
2.44
1.83
1.22
0.92
WS-X4606-X2-E
173
130
80
227
0.74
0.56
0.37
0.28
WS-X4624-SFP-E
60
45
12
205
0.67
0.50
0.33
0.25
WS-X4648-RJ45V-E
123
92
10
418
1.36
1.02
0.68
0.51
WS-X4648-RJ45V+E
123
92
10
418
1.36
1.02
0.68
0.51
Module Type/
Model Number
Table A-20
DC
Input
Power
(W)
DC
Output
Power
(W)
Heat
Dissipation
(BTU/Hr)
Input
Current
at -42
VDC (A)
Input
Current
at -48
VDC (A)
Input
Current
at -52
VDC (A)
Input
Current
at -58
VDC (A)
80
60
273
1.90
1.67
1.54
1.38
160
120
546
3.81
3.33
3.08
2.76
180
135
614
4.29
3.75
3.46
3.10
276
200
909
6.35
5.56
5.13
4.60
Model Number/
Module Type
A-20
OL-13972-02
Appendix A
Specifications
Power Use and Thermal Output
Table A-20
Model Number/
Module Type
DC
Input
Power
(W)
DC
Output
Power
(W)
Heat
Dissipation
(BTU/Hr)
Input
Current
at -42
VDC (A)
Input
Current
at -48
VDC (A)
Input
Current
at -52
VDC (A)
Input
Current
at -58
VDC (A)
WS-X45-SUP6-E
347
200
1182
8.25
7.22
6.67
5.98
WS-X45-SUP6L-E
267
200
909
6.35
5.56
5.13
4.60
WS-X45-SUP6-E
(standby)
247
185
841
5.87
5.14
4.74
4.25
WS-X45-SUP6L-E
(standby)
200
165
750
5.24
4.58
4.23
3.79
WS-X4606-X2-E
66.67
130
227
1.59
1.39
1.28
1.15
WS-X4624-SFP-E
60.00
45
205
1.43
1.25
1.15
1.03
WS-X4648-RJ45V-E
122.67 92
418
2.92
2.56
2.31
2.07
WS-X4648-RJ45V+E
122.67 92
418
2.92
2.56
2.36
2.11
A-21
Appendix A
Specifications
A-22
OL-13972-02