SPECIFIERS GUIDE
TABLE OF CONTENTS
Warranty Information
Product Features and Sizes
Parallam Plus PSL Applications
Design Properties
Hardware Recommendations and
Bearing Requirements
Beam Load Tables
Decks
Columns
Cladding Information
Q&A
2
3
4
5
5
67
8
9
10
1011
E XC L U S I V E & L I M I T E D 3 0 -Y E A R WA R R A N T Y
Trus Joist Parallam Plus PSL Specifier's Guide TJ-7102 | July 2015
Feature/Use Characteristics
AWPA Use Category
Saltwater Splash Permitted
Treatment
Kiln Dried After Treating
Decay Protection
Termite Protection
Corrosion-Resistant
Hardware Required
Suitable for Interior
Applications
Paintable or Stainable
Columns
UC4B or lower
Yes
CCA
Yes (KD 19)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Trus Joist Parallam Plus PSL Specifier's Guide TJ-7102 | July 2015
Use Categories
AWPA Use
Category
Service Conditions
Interior construction,
aboveground, dry
Use Environment
Continuously protected from weather
or other sources of moisture
Typical Applications
Interior construction,
aboveground, damp
Exterior construction, aboveground,
rapid water runoff
Exterior construction,
aboveground, poor water runoff
Ground contact or fresh water,
non-critical components
Ground contact or fresh water,
critical components or difficult repair
Ground contact or fresh water,
critical structural components
Salt or brackish water and adjacent
mud zone
Interior construction
UC1
UC2
UC3A
UC3B
UC4A
UC4B
UC4C
UC5A
Interior construction
This table has been adapted, with permission, from the 2014 AWPA Book of Standards (Standard U1-14, Table 2-1).
Service Levels
Service Level
1
2
3
Description
Dry Use
Wet Use
Saturated Use
Application Environment
Dry, interior
Repeated exposure to wet and dry cycles
Exposed to continuous wet conditions
Trus Joist Parallam Plus PSL Specifier's Guide TJ-7102 | July 2015
Not
permitted
Not
permitted
Not
permitted
Not
permitted
Not
permitted
Design Properties
Allowable Design Stresses for Beams and Columns (100% Load Duration)
Service
Level
G
Shear
Modulus
of Elasticity
(psi)
E
Modulus
of Elasticity
(psi)
E min
Adjusted
Modulus
of Elasticity
(psi)
Fb
Flexural
Stress (1)
(psi)
1
2
3
103,750
91,250
83,750
1.660 x 106
1.460 x 106
1.340 x 106
843,725(5)
742,070(5)
681,080(5)
2,117
1,827
1,624
1
2
3
93,375
82,125
75,375
1.494 x 106
1.314 x 106
1.206 x 106
759,350(6)
667,865(6)
612,970(6)
1,752(7)
1,512(7)
1,344(7)
[12]
Fc
Ft
Compression
Tension
Perpendicular
Stress (2)
to Grain(3)
(psi)
(psi)
Beam (4) Application
1,519
533
1,397
368
1,337
263
Column Application
1,316
215(7)
1,211
150(7)
1,158
110(7)
CRP
Creep
Factor
SG
Equivalent
Specific
Gravity
2,030
1,508
1,189
241
197
171
0.20
0.60
0.85
0.50
0.50
0.50
1,750
1,300
1,025
160(7)
120(7)
100(7)
0.20
0.60
0.85
0.50
0.50
0.50
Design Property
9"
7,820
4,255
231
11.7
Moment (ft-lbs)
Shear (lbs)
Moment of Inertia (in. 4)
Weight (plf)
General Notes
Fv
Horizontal
Shear Parallel
to Grain
(psi)
0.111
Fcll
Compression
Parallel
to Grain
(psi)
117 8"
12,540
5,465
488
15.1
14"
17,110
6,440
800
17.8
16"
22,020
7,360
1,195
20.3
14"
25,670
9,665
1,201
26.6
16"
33,030
11,045
1,792
30.5
Design Property
The following formula approximates the total load d eflection for a beam or header,
including creep deflection (CD), in inches:
Total load deflection TL = LL + DL + CD, where:
CD = [DL + LL (F)][CRP]
F = 0.2 for floors; 0.3 for roofs
9"
11,735
6,385
346
17.6
Moment (ft-lbs)
Shear (lbs)
Moment of Inertia (in. 4)
Weight (plf)
117 8"
18,810
8,195
733
22.6
Moisture Content
at Connection
28%
28%
> 28%
Lateral
Connections
0.7
0.7
0.4
Withdrawal
Connections
0.25
N.R.(1)
N.R.(1)
(1) Withdrawal connections in Service Level 3 applications are not recommended (N.R.).
Hardware Recommendations
Due to the high moisture content typically present where Parallam Plus PSL is
used, it is very important to use corrosion-resistant fasteners and connectors for all
applications. Fasteners include nails, screws, and bolts. Connectors include joist
hangers, post bases, and hurricane or mudsill anchors.
Reaction
2,000
4,000
6,000
8,000
10,000
12,000
14,000
16,000
18,000
20,000
22,000
24,000
26,000
28,000
30,000
Fasteners and connectors must have a coating that will provide the required level of
corrosion resistance for the treatment types, retention levels and end-use conditions
for ParallamPlus PSL. To ensure that you select appropriate hardware, follow the
hardware manufacturers recommendations for CA-C (no ammonia) with a retention
level of 0.15 pcf. If recommendations for CA-C are not provided, those for CA-B (no
ammonia) with a retention level of 0.21 pcf may be used.
Trus Joist Parallam Plus PSL Specifier's Guide TJ-7102 | July 2015
General Notes
Span
8'
10'
12'
14'
16'
100%
Floor
18'
20'
24'
28'
32'
Condition
Total Load
Live Load L/360
Min. End/Int. Bearing (in.)
Total Load
Live Load L/360
Min. End/Int. Bearing (in.)
Total Load
Live Load L/360
Min. End/Int. Bearing (in.)
Total Load
Live Load L/360
Min. End/Int. Bearing (in.)
Total Load
Live Load L/360
Min. End/Int. Bearing (in.)
Total Load
Live Load L/360
Min. End/Int. Bearing (in.)
Total Load
Live Load L/360
Min. End/Int. Bearing (in.)
Total Load
Live Load L/360
Min. End/Int. Bearing (in.)
Total Load
Live Load L/360
Min. End/Int. Bearing (in.)
Total Load
Live Load L/360
Min. End/Int. Bearing (in.)
9"
966
853
3.0/7.6
546
458
2.2/5.4
320
272
1.6/3.9
200
174
1.5/3.5
132
118
1.5/3.5
90
83
1.5/3.5
63
61
1.5/3.5
3" Width
14"
117 8"
1,347
1,427
*
*
4.2/10.6
4.5/11.3
988
1,137
918
*
3.9/9.8
4.5/11.3
660
933
554
875
3.2/7.9
4.4/11.1
421
677
358
570
2.4/5.9
3.8/9.5
282
459
244
391
1.9/4.6
3.0/7.4
196
322
173
279
1.5/3.7
2.4/5.9
140
233
127
206
1.5/3.5
2.0/4.9
76
130
74
121
1.5/3.5
1.5/3.5
76
*
1.5/3.5
16"
1,427
*
4.5/11.3
1,137
*
4.5/11.3
944
*
4.5/11.3
807
*
4.5/11.3
668
570
4.3/10.7
478
409
3.5/8.7
348
302
2.9/7.2
197
178
2.0/5.1
118
114
1.5/3.8
73
*
1.5/3.5
9"
1,449
1,280
3.0/7.6
819
686
2.2/5.4
479
408
1.5/3.9
300
261
1.5/3.5
198
177
1.5/3.5
135
125
1.5/3.5
94
92
1.5/3.5
5" Width
117 8"
14"
2,021
2,140
*
*
4.2/10.6
4.5/11.3
1,482
1,706
1,377
*
3.9/9.8
4.5/11.3
990
1,399
830
1,312
3.2/7.9
4.4/11.1
631
1,016
536
855
2.4/5.9
3.8/9.5
423
688
365
586
1.9/4.6
3.0/7.4
294
483
260
418
1.5/3.7
2.4/5.9
210
349
191
308
1.5/3.5
2.0/4.9
114
194
112
181
1.5/3.5
1.5/3.5
64
114
*
*
1.5/3.5
1.5/3.5
68
*
1.5/3.5
16"
2,140
*
4.5/11.3
1,706
*
4.5/11.3
1,417
*
4.5/11.3
1,210
*
4.5/11.3
1,002
855
4.3/10.7
717
613
3.5/8.7
522
454
2.9/7.2
296
268
2.0/5.1
178
171
1.5/3.8
110
*
1.5/3.5
General Notes
Lateral support is required at bearing and along the span at 24" on-center,
maximum.
Total load values are limited to deflection of L/240 and include creep deflection
with an assumed dead load to live load ratio of 30%. Live load values are based
on deflection of L/360. Check local code for other deflection criteria.
For conditions beyond the scope of this table, including applications other
than Service Level 2, use Weyerhaeuser software or contact your Weyerhaeuser
representative.
For deflection limits of L /240 and L/480, multiply Live Load L/360 values by
1.5 and 0.75 respectively. The resulting live load must not exceed the total load
shown.
Trus Joist Parallam Plus PSL Specifier's Guide TJ-7102 | July 2015
Span
8'
10'
12'
14'
115%
Snow
16'
18'
20'
24'
28'
8'
10'
12'
14'
125%
Non-Snow
16'
18'
20'
24'
28'
Condition
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
Total Load
Live Load L/240
Min. End/Int. Bearing (in.)
9"
1,113
*
3.5/8.7
705
686
2.8/7.0
414
408
2.0/5.0
261
*
1.5/3.7
173
*
1.5/3.5
119
*
1.5/3.5
84
*
1.5/3.5
1,210
*
3.8/9.5
705
686
2.8/7.0
414
408
2.0/5.0
261
*
1.5/3.7
173
*
1.5/3.5
119
*
1.5/3.5
84
*
1.5/3.5
3" Width
117 8"
14"
1,432
1,427
*
*
4.5/11.3
4.5/11.3
1,138
1,137
*
*
4.5/11.2
4.5/11.3
786
944
*
*
3.7/9.3
4.5/11.3
545
785
536
*
3.1/7.6
4.4/10.9
367
594
365
586
2.4/5.9
3.8/9.5
256
419
418
*
1.9/4.7
3.1/7.6
184
304
*
*
1.6/3.9
2.5/6.3
102
172
*
*
1.5/3.5
1.8/4.4
59
103
*
*
1.5/3.5
1.5/3.5
1,432
1,427
*
*
4.5/11.3
4.5/11.3
1,143
1,137
*
*
4.5/11.3
4.5/11.3
852
944
830
*
4.0/10.1
4.5/11.3
545
807
536
*
3.1/7.6
4.5/11.3
367
594
365
586
2.4/5.9
3.8/9.5
256
419
418
*
1.9/4.7
3.1/7.6
184
304
*
*
1.6/3.9
2.5/6.3
102
172
*
*
1.5/3.5
1.8/4.4
59
103
*
*
1.5/3.5
1.5/3.5
16"
1,427
*
4.5/11.3
1,137
*
4.5/11.3
944
*
4.5/11.3
807
*
4.5/11.3
703
*
4.5/11.3
605
*
4.4/10.9
453
*
3.7/9.2
259
*
2.6/6.5
158
*
1.9/4.9
1,427
*
4.5/11.3
1,137
*
4.5/11.3
944
*
4.5/11.3
807
*
4.5/11.3
703
*
4.5/11.3
620
613
4.5/11.2
453
*
3.7/9.2
259
*
2.6/6.5
158
*
1.9/4.9
9
1,669
*
3.5/8.7
1,058
1,029
2.8/7.0
621
611
2.0/5.0
391
*
1.5/3.7
259
*
1.5/3.5
178
*
1.5/3.5
126
*
1.5/3.5
66
*
1.5/3.5
1,816
*
3.8/9.5
1,058
1,029
2.8/7.0
621
611
2.0/5.0
391
*
1.5/3.7
259
*
1.5/3.5
178
*
1.5/3.5
126
*
1.5/3.5
66
*
1.5/3.5
5" Width
117 8"
14"
2,140
2,140
*
*
4.5/11.3
4.5/11.3
1,706
1,706
*
*
4.5/11.2
4.5/11.3
1,179
1,417
*
*
3.7/9.3
4.5/11.3
818
1,178
804
*
3.1/7.6
4.4/10.9
550
892
548
879
2.4/5.9
3.8/9.5
384
629
627
*
1.9/4.7
3.1/7.7
276
457
*
*
1.6/3.9
2.5/6.3
152
257
*
*
1.5/3.5
1.8/4.4
88
154
*
*
1.5/3.5
1.5/3.5
2,140
2,140
*
*
4.5/11.3
4.5/11.3
1,706
1,706
*
*
4.5/11.3
4.5/11.3
1,278
1,417
1,245
*
4.0/10.1
4.5/11.3
818
1,210
804
*
3.1/7.6
4.5/11.3
550
892
548
879
2.4/5.9
3.8/9.5
384
629
627
*
1.9/4.7
3.1/7.7
276
457
*
*
1.6/3.9
2.5/6.3
152
257
*
*
1.5/3.5
1.8/4.4
88
154
*
*
1.5/3.5
1.5/3.5
16"
2,140
*
4.5/11.3
1,706
*
4.5/11.3
1,417
*
4.5/11.3
1,210
*
4.5/11.3
1,055
*
4.5/11.3
908
*
4.4/10.9
680
*
3.7/9.2
389
*
2.6/6.5
237
*
1.9/4.9
2,140
*
4.5/11.3
1,706
*
4.5/11.3
1,417
*
4.5/11.3
1,210
*
4.5/11.3
1,055
*
4.5/11.3
930
919
4.5/11.2
680
*
3.7/9.2
389
*
2.6/6.5
237
*
1.9/4.9
General Notes
Total load values are limited to deflection of L /180 and include creep deflection
with an assumed dead load to live load ratio of 30%. For stiffer deflection criteria,
Live Load L/240 values are provided. Check local code for other deflection criteria.
Lateral support is required at bearing and along the span at 24" on-center,
maximum.
For conditions beyond the scope of this table, including applications other
than Service Level 2, use Weyerhaeuser software or contact your Weyerhaeuser
representative.
Trus Joist Parallam Plus PSL Specifier's Guide TJ-7102 | July 2015
DECKS
All lumber framing used in deck applications should be pressure
treated to AWPA Standards or recognized in an ICC ES code report.
Flashing
Decking
Joists
2" minimum
2" minimum
Joists supported by
treated 2x_ ledger
Parallam Plus
beams and
columns
Jois
t sp
Live Load
40 psf
60 psf
Joist Span
up to 9'
9' to 16'
up to 7'
7' to 14'
14' to 16'
an
Column height
Connection Type
and Spacing (1)
Two rows " lag bolts
32" on-center, staggered
16" on-center
32" on-center, staggered
16" on-center
12" on-center
Column height
2' maximum
beam cantilever
Embedded
concrete
footer
n
um
Col cing
spa
vel
le
und
Gro
n
um
Col cing
spa
40LL +10DL
60LL + 10DL
Joist Span
8'
10'
12'
14'
16'
8'
10'
12'
14'
16'
General Notes
3. Scan across the row to find both the Maximum Column Spacing and Maximum
Column Height that meet or exceed your condition.
Trus Joist Parallam Plus PSL Specifier's Guide TJ-7102 | July 2015
columns
Allowable Axial Loads (lbs)Service Level 2
Effective
Column
Length
6'
8'
10'
12'
14'
16'
18'
20'
100%
10,580
7,550
5,485
4,125
3,205
3" x 5"
115%
11,330
7,885
5,665
4,235
3,280
Slenderness ratio
exceeds 50
125%
11,760
8,080
5,770
4,300
3,320
100%
20,330
17,285
14,005
11,185
9,020
7,385
6,140
5,175
Column Size
5" x 5"
115%
22,680
18,775
14,845
11,695
9,355
7,615
6,305
5,300
125%
24,150
19,650
15,325
11,985
9,545
7,750
6,405
5,375
100%
38,850
35,685
31,785
27,470
23,300
19,705
16,760
14,375
7" x 7"
115%
40,000
39,815
34,780
29,445
24,605
20,615
17,420
14,870
125%
40,000
40,000
36,570
30,585
25,355
21,135
17,800
15,155
General Notes
Table
is based on:
Solid, one-piece column members.
Bracing in both directions at column ends.
NDS.
Simple columns with axial loads only. For side loads or other combined bending and axial loads, see the NDS.
Allowable loads have been adjusted to accommodate the worst case of the following eccentric conditions: 16of the column
thickness (first dimension) or 16of the column width.
conditions beyond the scope of this table, including applications other than Service Level 2, use Weyerhaeuser software or
For
contact your Weyerhaeuser representative.
WARNING: Drilling, sawing, sanding or machining wood products generates wood dust. The paint and/or coatings on this product may contain titanium dioxide.
Wood dust and titanium dioxide are substances known to the State of California to cause cancer. For more information on Proposition 65, visit wy.com/inform.
Deck joist
Optional
non-shrink
grout
P3
L27
DO NOT
size base
plate larger
than column
Wide face
of strands
Wide face
of strands
Trus Joist Parallam Plus PSL Specifier's Guide TJ-7102 | July 2015
CLADDING INFORMATION
Cladding on Beams
Parallam Plus PSL is suitable for exposed conditions with wet-dry moisture cycles.
However it may be desirable for aesthetic reasons to wrap the product in a decorative
cladding. As with all treated wood products, avoid applications that can trap
moisture. If decorative cladding is used, the following considerations are critical for
Parallam Plus PSL to perform satisfactorily:
Cladding
The designer, builder, and owner must share responsibility for ensuring that the
assembly is designed, installed, and maintained in a way that will prevent water
from entering and being trapped.
If the prevention of water intrusion over the life of the structure cannot be
assured, then cladding must be designed and installed in a manner that allows
adequate drainage and sufficient air-flow to facilitate drying. Suggested beam
and column details are shown at right.
Metal cladding materials should not be used, as the preservative treatment can
react with the metal and lead to corrosion of the cladding and fasteners.
All fasteners, furring strips, and other materials used in the cladding assembly
must be corrosion-resistant, treated, or otherwise resistant to decay.
IMPORTANT: Moisture trapped inside the cladding may cause mold. The treatment used
in Parallam Plus does not prevent mold.
Cladding on Columns
For column bases with ground contact, maintain a 3" (minimum) gap between
cladding and finish grade for drainage. For bases with patio or deck surface
contact, maintain a 1" (minimum) gap between cladding and surface.
Cladding
Q&A
Q1: What is Parallam Plus PSL?
A1: Parallam Plus PSL is Parallam PSL that has been treated with Arch
of treatment, and treating facility. The stamp also references the treating
standards and third-party quality program monitor. The following stamps are
examples of those found on Parallam Plus PSL.
Only Parallam Plus PSL is manufactured using these methods, and it's the
only product covered by both Weyerhaeuser (structural) and Arch (treatment)
limited 30-year warranties.
AWPA U1/C33
0.15 pcf CA-C KDAT 19% SYP
COX INDUSTRIES, INC.
AWPA U1/C33
0.60 pcf CCA-C KDAT 19% SYP
COX INDUSTRIES, INC.
applications such as deck railings and play sets. However, CCA is an excellent
preservative and remains an approved form of treatment for Parallam PSL
columns used in structural ground-contact applications (AWPA UC4B).
Trus Joist Parallam Plus PSL Specifier's Guide TJ-7102 | July 2015
10
Q&A (continued)
Q10: Do I need to field-treat holes or end cuts?
A10: No. For the standard sizes shown in this guide, the unique structure of
Parallam Plus PSL columns are well suited for residential applications such
as structural support columns, deck posts, and retaining walls. It is ideal for
applications that result in occasional, intermittent saltwater splash exposure
that will not support degradation by marine organisms.
The U.S. EPA concluded that CCA-treated wood does not pose unreasonable
risks to the public, and they do not require CCA-treated products to be
removed from service, coated/sealed, or encapsulated. However, they do
note that the use of a suitable coating could reduce potential exposure.
to the next. The NDS defines dry service for structural composite lumber
products as an in-service moisture content of less than 16%. CSA O86
defines dry service as a climatic condition in which the average equilibrium
moisture content (EMC) of sawn lumber over a years time is 15% or less and
does not exceed 19%.
contact may occur, but at a level or time period insufficient to support the
growth of marine organisms. Examples of incidental saltwater exposure
include members used in proximity to saltwater and exposed to occasional
or intermittent splash from storms or waves, or to saltwater spray or mist.
Examples of conditions that would not be appropriate for Parallam Plus PSL
include members that are in or adjacent to the tidal zone where they would
remain wetted with saltwater for extended periods of time.
available on woodbywy.com:
Consumer Safety Information Sheet for Trus Joist Parallam Plus PSL,
TJ-1021
Also see the following Material Safety Data Sheets (MSDSs), available at
weyerhaeuser.com/Sustainability/Planet/ProductStewardship/MSDS:
Parallam Plus PSL that is intended for beam and header applications is
treated with copper azole at a retention level that eliminates the need to
use stainless steel connectors and fasteners in most applications. Refer to
hardware manufacturers recommendations for your specific application.
is different than the level used for columns and is not suitable for heavy-duty,
structural, ground-contact applications. However, if the product is being used
in SL1 or SL2 (or even AWPA UC4A) applications, the preservative treatment
is suitable and the beam may be used as a column.
Trus Joist Parallam Plus PSL Specifier's Guide TJ-7102 | July 2015
11
CONTACT US
1.888.453.8358 woodbywy.com/contact
Contact your local representative or dealer at: