ACRYDIG 4 -10

INTRODUCTION
This instruction is an integral part of the delivery device and has to be accompanied during any
migration.
Operating be retained for the lifetime of the device and under all circumstances for at least 10 years, must
therefore keep a familiar place and must be accessible to all who work with it work.
Do instrument or do not start until you read this manual.
Fig. 1
1.
2.
3.
4.

Cover
Control panel for temperature
Main switch
Cable and plug

SPECIFICATIONS
L'ACRYDIG 4 comes in Following COMES
design
220/240 V 50/60 Hz
L'ACRYDIG 10 is supplied following
execution
220/240 50/60 Hz

Power
consumptio
n
Width
Height
Depth
Net weight

ACRYDIG 4
1100W

ACRYDIG 10
1430 W

13 cm + 2 cm
in supply cable
37.5 cm
42 c m
8 kg

28 cm + 2 cm
in supply cable
37.5 cm
42 cm
10 kg

APPLICATION EQUIPMENT
Acrydig 4 and 10 are polymeriztory Acrydig resin. They inserted into them in resin models unset state
and a certain amount of water.
Device heats the water to a temperature below the boiling point, which is maintained for the required
period and the heating is continued until the desired final temperature, which is also maintained for the
required period.This cycle processes causing polymerization resins.
Unpacking
The unit is supplied in cardboard kabici. Before unpacking, remove metal pins on the top of the box and
then remove polymeriztor.

NOTICE
Check that:
AC cord and plug are not damaged
on polymeriztoru no evidence of damage or fall
Electricity has interrupting the safety earth connection it
Nevnoujte cable into the water.
Keep cable well away from heat sources.
Do not let the cord hang over the edges of furniture.
Pour the water into the unit before any manipulation. If he accidentally started in the heating cycle the
absence of water, the resistance burned.
INSTALLATION
-

Place the device on a flat, stable surface to hold its weight.


Polymeriztor must be connected to the correct current and voltage according to its technical
characteristics and must be grounded.
The appliance must be earthed.
They must be installed by a qualified
electrician able to check the grounding.
Manufacturer disclaims responsibility for any
damage caused by failure to comply with this
requirement.
CONTROL PANEL
Buttons
RUN

Press to start the heating cycle us


Pressed for about 6 seconds, the heating cycle is terminated
When pressed after a power failure, the display stops flashing.
When pressed during programming, the figure on the display increases
Not during runtime.
When pressed during the programming, the figure goes on display
Not during runtime.

FUNC
-

Presses when the device is in rest (OFF on the lower display). It allows for programming,
inserting parameters and their preservation.

When pressed during runtime, see the parameters of the heating cycle without interruption.

LIGHTS
OUT
SP
TIME
-

This indicator lights when the current heating resistors


This indicator lights when the temperature rises. Turns off when the programmed temperature is
reached.
This light is turned on during a phase of stabilization

DISPLAY
UPPER
During programming, shows the temperature and time that must be loaded into memory or
altered
During the run-in phase, showing the rise of water temperature in the stabilization phase shows
the relevant times.
BOTTOM
This display shows OFF when the device is in peace
When programming or changing parameter settings shown in the following abbreviations:
FSE current stage
SP1 first temperature to be stabilized
TS1 period during which to maintain the first temperature
SP2 final temperature
TS2 time during which to keep the final temperature
INSTRUCTIONS FOR CONTROL
Programming
Note: You can program only when the device is in rest (OFF on the lower display and lights SP
TIME and off).
Yapnte yayen main switch.
Press FUNC and start programming. On the lower display shows the FSE and the upper 0. This
parameter can not be changed, proceed to the tkae next point.
Press FUNC: the lower display shows SP1 and the top shows the programmed transition (first)
temperature. To change the temperature to the desired value by pressing the or .
Press FUNC: the lower display shows the TS1 and the top shows the programmed time
maintaining the temporary (first) temperature. This time change to the desired value by pressing
the or .
Press FUNC: the lower display shows SP2 and upper programmed final temperature. To change
the temperature to the desired value by pressing the or .

Press FUNC: the lower display will appear on the upper and TS2 programmed time during
which to keep the final temperature. This time change to the desired value by pressing the or .
Note: if you want to bring water to a boil, it is necessary to bear in mind the fact that the boiling point
is different at different altitudes, as it ukayuje following table.
Height (m)
Boiling Point C)
500
98
1000
97
1500
95
2000
93
2500
92
3000
90
If you set the temperature higher than the boiling point, can not be achieved and the cycle thus be unable
to continue.
Exit the programming phase, pressing the FUNC. On the lower display shows OFF and the
upper appear instantaneous temperature.
Starting the program
Note: You can program only when the device is in rest (OFF on the lower display and lights SP TIME
and off).
Start heating cycle by pressing RUN. Lamp lights SP and the lower display shows the temperature to be
reached. Once this temperature is reached, the light goes out and the warning light TIME. The lower
display shows the time remaining to stabilize. The two previous stages are repeated in the ascent to the
final t ePlot
and its stabilization.
Stopping the program
Press RUN to about 6 seconds, and the program stops. On the lower display shows again the word OFF.
Blackout
If the power supply fails, the program will start again the point where it was interrupted, but the displays
are flashing. Stop flashing, press RUN.
STEAM POLYMERIZATION
When steam polymerization, follow these steps:
polymeriztoru to pour enough water so that the aid of shock absorbers remain under
water. Shock itself to be out of the water.
Do not use a provisional (temporary) temperature, so that the device is adjusted to a final
temperature (usually between 70 and 80 C) corresponding to the minimum time (1
minute). Then set the final temperature and the appropriate duration corresponding to the time
required for the polymerization (usually 6 to 8 hours).

Caution: Always make sure that your heating system is underwater.


GUARANTEE
On the instrument are warranted for 12 months.
The warranty will be void in cases of improper use, damage to or use of spare parts that
n epochzej from producer.
Have cast warranty card is immediately void the warranty.
The warranty does not cover charges for labor or services that are always and in all circumstances be
borne by the buyer.