AIR CONDITIONING
FCDKADNA743AAN_dkadna_uk
10:08
Page 4
Range
INDUSTRIAL
Electric heating
(in duct)
FCDKADNA743AAN_dkadna_uk
10/09/03
10:08
Page 1
SPLIT-SYSTEM
This complete range includes
6 models of "Axial" condensing
units single or dual circuits
depending on models, and
6 models of indoor air treatment
units for ducted air distribution.
DN-A INDOOR AIR
TREATMENT UNITS
DK-A
405/505/605
size premises.
CONDENSING
UNITS
DK-A
205/255/305
ST S 4370 P
S 5670 P
WAREHOUSES
FACTORIES
OPERATION AND
MANAGEMENT.
conditioned, depending on
SWITCH
- ROOM TEMPERATURE
requirements.
SETTING
- LOCAL OR REMOTE NIGHT
WORKSHOPS
SLOW-DOWN SETTING
- AUTOMATIC RESTARTING
AFTER POWER CUTS.
FIELDS OF APPLICATION
FCDKADNA743AAN_dkadna_uk
10/09/03
10:08
Page 2
Cooling
only
Heatpump
Electric
heating
(in ducting)
400
A D V A N T A G E S
1350
1060
DK-A 305
Net weight : 160 kg
DK-A 405
Net weight : 160 kg
676
DK-A 505
Net weight : 205 kg
DK-A 605
Net weight : 209 kg
991
704
1064
CONDENSING UNITS
DN-A 205
Net weight : 164 kg
DN-A 255
Net weight : 164 kg
1006
temperatures.
THE "AXIAL"
CONDENSING UNITS
ARE TO BE INSTALLED OUTDOORS.
THUS THERE IS NO REQUIREMENT
FOR PROVIDING A TECHNICAL
SERVICES ROOM OR MAKING
BUILDING ALTERATIONS
803
DN-A 305
Net weight : 187kg
903
1006
1003
DN-A 405
Height : 964
Net weight : 317 kg
DN-A 505
Net weight : 378 kg
DN-A 605
Net weight : 405 kg
1003
1165
except
DN-A 405 :
964
1708
PIPING LENGTH: 30 M MAX.
LEVEL VARIATION: 15 M.
25 M FOR COOLING MODELS
(DK-A ABOVE DN-A)
1125
FCDKADNA743AAN_dkadna_uk
10/09/03
10:08
Page 3
TECHNICAL SPECIFICATIONS
205
255
305
405
505
605
W
BTU/HR
19100
65150
22000
75040
28100
95850
36500
124500
45500
155200
56600
193050
7100
8300
11500
14300
17100
22800
Nominal
Minimum
Maximum
m3/h
m3/h
m3/h
4500
3600
5000
4680
3700
5100
5760
4600
6350
7560
6000
8300
9360
7500
10300
9720
7780
11000
daPa
7/21
5/20
10/19
10/19
11/21
14/22
dBA
dBA
81
83
82
83
79
87
81
88
80
87
81
93
Refrigerant circuit(s)
Nominal cooling
capacity (1)
Total nominal power input
Fan + cooling
205RC
255RC
305RC
405RC
505RC
605RC
Nominal cooling
capacity (1)
W
BTU/HR
19100
65150
22000
75040
28100
95850
36500
124500
45500
155200
56600
193050
Nominal heating
capacity (2)
W
BTU/HR
19100
65150
21800
74300
27300
93100
36500
124500
43800
149500
56100
191300
W
W
7100
6400
8300
7000
11500
8000
14300
12100
17100
14100
22800
20000
Nominal
Minimum
Maximum
m3/h
m3/h
m3/h
4500
3600
5000
4680
3700
5700
5760
4600
6350
7560
6000
8300
9360
7500
10300
9720
7780
11000
daPa
7/21
5/20
10/19
10/19
11/21
14/22
dBA
dBA
81
83
82
83
79
87
81
88
80
87
81
93
PIPING LENGHT
Maximum length
Level variance (3)
m
m
30
15
30
15
30
15
30
15
30
15
30
15
Inch
Inch
1 1/8
1 1/8
1 1/8
1 3/8
1 1/8
1 3/8
1 1/8
1 1/8
1 1/8
1 3/8
1 1/8
1 3/8
Inch
Inch
1/2
1/2
1/2
5/8
1/2
5/8
1/2
1/2
1/2
5/8
1/2 (>10m)
5/8 (<10m)
Airflow
The values are given for nominal voltage supply; NF EN 255.2 - NF EN 814.2 standards.
(1) Type A international conditions: 27 C / 19 C wet bulb. Outdoor air 35 C / 24 C wet bulb.
(2) International conditions: 20 C / 12 C wet bulb. Outdoor air 7 C / 6 C wet bulb.
(3) Refer to technical specifications for vertical piping length (25 m max. depending on configuration in Cooling Only)
Your distributor
ACE MARKETING - RCS VERSAILLES B 421 305 996 - Specifications subject to change without notice - Pictures non contractual -
3N~400V-50Hz
Power supply
- Printed in E.U.
Airflow