Condensate Pump

Operation Procedure
Page 1 of 7

Work Instruction
G1-7027 A/B

Revision no.

Prepared by

Effective date

Issue no.

DCC

Signature

Name Surname

Date

Guruh Iriyanto

12/05/2015

Reviewed by
Approved by

REVISION HISTORY
Revision : 00
Date :

Condensate Pump
Operation Procedure
Page 2 of 7

Rev.

Effective date

00

Revision : 00
Date :

Description of Revision
Initial Issue

Prepared

Reviewed

Approved

Condensate Pump
Operation Procedure
Page 3 of 7

ENGLISH

BAHASA INDONESIA

1.

UNIT
Utility

1.

UNIT
Utility

2.

SYSTEM
Turbine

2.

SISTIM
Turbin

3.

SAFETY
Ensure all permits are signed off

3.

KESELAMATAN
Pastikan semua

ijin

kerja

sudah

ditandatangani
Ensure
Operator
recommended PPE

is

wearing

Pastikan operator menggunakan PPE


yang disarankan

Ensure All Equipment in good condition


and ready to start

4.

CONDENSATE PUMP G1-7027 A/B


START UP PROCEDURE
Preparation:
Ensure electrical power sources for
condensate pump G1-7027 A/B
available
Ensure all instrumentation equipment
ready
Ensure around the equipment is free
Ensure the sealing valve has opened

ENGLISH
Revision : 00
Date :

Semua Equipment dalam kondisi siap


untuk dijalankan.
4.

PROSEDUR START CONDENSATE


PUMP G1-7027 A/B
Tahap Persiapan:
Pastikan Source power untuk condensate
pump G1-7027 A/B sudah tersedia
Semua

peralatan

instrument

dalam

kondisi baik
Pastikan Kondisi di sekitar equipment ter
bebas dari gangguan
Pastikan sealing valve sudah terbuka

Condensate Pump
Operation Procedure
Page 4 of 7

BAHASA INDONESIA
Ensure inlet and outlet valve of pump
opened
Ensure hot well level normal F1-7026
START CONDENSATE PUMP

Pastikan valve inlet dan outlet pompa


sudah terbuka
Pastikan level hot well normal F1-7026

Start Condensatel Pump From DCS


START CONDENSATE PUMP G1-7027 A/B
Change the Switch remote/local at
MCC into remote/DCS Position
Select icon Condensate pump on DCS
display
Select start Condensate pump from
DCS
Ensure light indicator Condensate
pump ONat display/monitor
Ensure pump current is normal
Ensure Condensate pump started in
good condition, and there are no
abnormality such as noice,vibration,or
temperature

Start Condensate Pump Dari DCS


Pindahkan Switch remote/local pada
MCC ke posisi remote/DCS Pilih icon
Condensate pump G1-7027 A/B
pada disply DCS
Start Condensate pump G1-7027 A/B dari
DCS
Lihat

indikasi

pada

display

bahwa

Condensate pump sudah jalan


Pastikan current Condensate pump G17027 A/B normal
Pastikan Condensate pump G1-7027 A/B
bekerja dalam kondisi normal tidak ada
abnormality baik suara,vibrasi,atau pun
temperature

Revision : 00
Date :

Condensate Pump
Operation Procedure
Page 5 of 7

ENGLISH

BAHASA INDONESIA

Start Condensate Pump From Local

Start Condensate Oil Pump Dari Local

Change the Switch remote/local at

Pindahkan Switch remote/local pada

MCC/panel into remote local Position


Start Condensate pump from local
panel

MCC/Panel ke posisi Local


Start Condensate pump G1-7027 A/B dari
panel local

Ensure pump running and check light

Pastikan

pompa

running

dan

indicator on local panel/MCC light

indikasi lampu pada panel local/MCC

On

menyala

Ensure pump current is normal


Ensure Condensate pump started in

Pastikan current Condensate pump G17027 A/B normal

good condition, and there are no

Pastikan Condensate pump bekerja dalam

abnormality such as noise, vibration

kondisi normal tidak ada abnormality

or temperature

baik suara, vibrasi atau pun temperature

BAHASA INDONESIA
ENGLISH
Revision : 00
Date :

lihat

STOP CONDENSATE PUMP G1-7027 A/B

Condensate Pump
Operation Procedure
Page 6 of 7

STOP CONDENSATE PUMP G1-7027 A/B


Stop Condensate Pump G1-7027 From DCS
Change the Switch remote/local at
MCC into remote/DCS Position
Select icon Condensate pump G17027A/B on DCS display
Select stop Condensate pump from
DCS
Ensure light indicator Condensate
pump G1-7027A/B light off at
display/monitor
Ensure pump current is decrease (0 A)

Stop Condensate Pump G1-7027 A/B Dari DCS


Pindahkan Switch remote/local pada
MCC ke posisi remote/DCS
Pilih icon Condensate pump G1-7027
A/B pada disply DCS
Stop Condensate pump G1-7027 A/B dari
DCS
Lihat

indikasi

pada

display

bahwa

Condensate pump G1-7027 A/B sudah


stop
Pastikan current Condensate pump G17027 A/B turun (0 A)
Stop Condensate Pump G1-7027 A/B Dari
Local

Stop Condensate Pump G1-7027 A/B


From Local
Change the Switch remote/local at
MCC/panel into remote local Position
Stop Condensate pump from G17027A/B local panel
Ensure pump stop and check indicator
at local panel/MCC light off
Ensure condensate G1-7027A/B pump
current is decrease (0 A)

Revision : 00
Date :

Pindahkan Switch remote/local pada


MCC/Panel ke posisi Local
Stop Condensate pump G1-7027 A/B dari
panel local
Pastikan pompa stop dan lihat indikasi
lampu pada panel local/MCC mati
Pastikan current Condensate pump G17027 A/B turun (0 A)

Condensate Pump
Operation Procedure
Page 7 of 7

Revision : 00
Date :