UEIK-21RSD
EUROCARD TYPE
FUNCTIONAL BLOCK DIAGRAM
FRONT PANEL
FAULT SIGNAL
RED LED
Off: normal operation
On: transducer fault
DUPLOMATIC
TECHNICAL CHARACTERISTICS
Power supply
Required power
V DC
22 30
Ripple included
45
Output current
Power supply electrical
protections
Reference signal:
Voltage
Current
Input reference signal
impedance:
Voltage
Current
10
4 20
10
250
in compliance with
2004/108/CE
Card size
Eurocard 100x160x35
Connector interface
24 V DC POWER
SUPPLY
YELLOW LED
On: normal operation
Off: card
disconnected, faulty
power supply to card
or fuse blown
FAULT
POWER ON
ENABLE
CARD ENABLE
GREEN LED
Off: disabled
On: enabled
GAIN A
OFFSET A
GAIN B
OFFSET B
RAMP UP
RAMP DOWN
CURRENT A
CURRENT B
REFERENCE
TRANSDUCER
COMMON 0V
UEIK-21RSD/52-24
MADE IN ITALY
Ramp up regulation
Solenoid A current
measurement point (1V=1A)
Solenoid B current
measurement point (1V=1A)
Reference signal
measurement point
Transducer signal
measurement point ( 4,8V
tolerance + 200 mV)
Common zero
0 50
Mass
kg
0,27
89 335/110 ED
1/4
UEIK-21RSD
SERIES 52
1 - IDENTIFICATION CODE
U E I K - 21 R S D / 52 - 24
Power supply voltage = 24 VDC
2 - FUNCTIONAL SPECIFICATIONS
2.1 - Electric power supply
The card requires a power supply of 22 - 30 V DC and 45 W (pin
2a/2c - 4a/4c).
Power supply voltage must be rectified and filtered, with maximum
admissible ripple within the above voltage range.
2.2 - Electrical protection
The card is protected against overvoltage and polarity inversion.
A 3,15A fast-acting fuse is fitted for power circuit protection.
89 335/110 ED
2/4
UEIK-21RSD
SERIES 52
4 - SIGNAL MEASUREMENT
4.1 - CURRENT A / CURRENT B
(Current measurement points of solenoids A and B)
Measurement points for voltage readings of current supplied to
solenoids A and B. Reading conversion is 1V DC = 1A.
c) RAMP REGULATION
Regulate the RAMP UP and RAMP DOWN potentiometers
to obtain the required valve smoothness od movement with a
reference position.
5 - INSTALLATION
The card is suitable for assembly on a rack or a card holder with
interface for connector types DIN 41612 - size D - 32 pole.
It is recommended to use cable sections of 1 to 2,5 mm2, in function
with their length, for power supply and solenoid connections. For
other connections, it is recommended to use cables with a screened
sheath connected to earth only on the card side.
NOTE 1: To observe EMC requirements it is important that the
control unit electrical connection is in strict compliance with the
connection scheme of par. 9.
As a general rule, the valve and the electronic unit connection wires
must be keeped as far as possible from interference sources (e.g.
power wires, electric motors, inverters and electrical switches).
In environments that are critical from the electromagnetic interference
point of view, a complete protection of the connection wires can be
requested.
6 - DEFAULT CONDITIONS
The electronic control unit is supplied factory-set. Standard settings
are:
GAIN A regulation: +10V (or 20 mA) reference signal
corresponding to maximum valve opening in the hydraulic
configuration controlled by solenoid A (transducer = -5V) .
GAIN B regulation: -10V (or 4 mA) reference signal
corresponding to maximum valve opening in the hydraulic
configuration controlled by solenoid B (transducer = +5V).
In open loop GAIN A and GAINB regulations correspond to a
current supply of 1,8 A to the solenoids A and B with maximum
reference signal.
OFFSET A or OFFSET B regulation: zero
RAMP UP and RAMP DOWN regulation: minimum
position SW1 on V
position SW2 on S
position SW3 on AC
position S1 on N
switching frequency (PWM) = 300 Hz
89 335/110 ED
3/4
UEIK-21RSD
SERIES 52
2a
2c
4a
4c
8a
CLOSE TO
ENABLE
24c
CLOSE TO
RAMP INHIBIT
16a
+V
POWER ON
yellow
led
fuse
3,15A-RAP
-V
-V
FAULT
red led
T.P. COMMON 0V
enable
T.P. REFERENCE
ramp by pass
12a
default
V
12c
REFERENCE SIGNAL
D
S
default
OFFSET A
D
U
-10V
ENABLE
green
led
PID
6a CLOSE =
CORRECT
6c
FUNCTION
max load I=0.25A
PWM
current
amplifier
D
current
feedback
T.P. CURRENT A 1V=1A
current
PWM
amplifier
RAMP
OFFSET B GAIN B
selection of single
ender or differential
AA
reference
AC default
current
feedback
T.P. CURRENT B 1V=1A
REFERENCE SIGNAL
CURRENT
I
VOLTAGE
V
T.P. TRANSDUCER
12a
420mA
12c
12a
10V
12c
default
N
4ac
V
POTENTIOMETER
10K TYP.
Zero
26a
26c
28a
28c
30a
30c
32a
32c
2
1
3
TRS EVa
EVb
Gain
210V
10a
12a
10V
10c
4ac
OK card
Down
reference
type
selection
GAIN A
Up
+10V
+V
0V
23V
0V
24a
8c
22c
DUPLOMATIC
SW1
V
3,15A-RAP
SW2
FAULT
POWER ON
AC
GAIN A
OFFSET A
SW3
ENABLE
FAULT
POWER ON
ENABLE
FUSE
GAIN A
OFFSET A
PT7
AA
GAIN B
OFFSET B
RAMP UP
100
N
129
(3HE)
OFFSET B
RAMP UP
RAMP DOWN
S1
RAMP DOWN
GAIN B
switching frequency
test point
(positive)
connect the probe
negative
to the COMMON 0V
CURRENT A
CURRENT B
CURRENT A
CURRENT B
REFERENCE
REFERENCE
T.GAIN
TRANSDUCER
T.ZERO
TRANSDUCER
COMMON 0V
COMMON 0V
UEIK-21RSD/52-24
MADE IN ITALY
14
160
35
(7TE)
89 335/110 ED
REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS.
4/4