Anda di halaman 1dari 11

VERIFICATION OF THE ULTIMATE

PUNCHING SHEAR RESISTANCE


EUROCODE 2

GEODOMISI Ltd. - Dr. Costas Sachpazis


Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Foundation Engineering & Retaining Structures.
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 - Mobile: (+30) 6936425722 & (+44) 7585939944,

www.geodomisi.com

- costas@sachpazis.info

Project: VERIFICATION OF THE ULTIMATE PUNCHING Job Ref.


SHEAR RESISTANCE to EUROCODE2 1992-1-1:2004
www.geodomisi.com
with NA=CEN.
GEODOMISI Ltd. - Dr. Costas Sachpazis

Section

Civil & Geotechnical Engineering Consulting Company for


Structural Engineering, Soil Mechanics, Rock Mechanics,
Foundation Engineering & Retaining Structures.
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 Mobile: (+30) 6936425722 & (+44) 7585939944,

www.geodomisi.com - costas@sachpazis.info

Sheet no./rev. 1

Civil & Geotechnical Engineering


Calc.
Dr. C. Sachpazis

Date
16/01/2016

Chk'd by
Date

App'd by

Date

INDEX

DESCRIPTION

CHECKS
1.- Zone adjacent to the support or load (Persistent situations)
2.- Zone with punching shear reinforcement (Persistent situations)

3
5

3.- External zone


situations)

to

the

punching

shear

reinforecement

(Persistent

4.- Punching shear reinforcement (EN 1992-1-1:2004/AC:2008, 9.4.3(2))


5.- Clear distance between two isolated consecutive bars

9
9

6.- Distance between the support's face and the first punching shear
reinforcement
10
7.- Distance between transverse consecutive reinforcement perimeters

10

8.- Distance between two consecutive reinforcements in peripheral direction 11


9.- Distance between the support's external face and the outermost bar
inclined at 45
11

Project: VERIFICATION OF THE ULTIMATE PUNCHING Job Ref.


SHEAR RESISTANCE to EUROCODE2 1992--1-1:2004
www.geodomisi.com
with NA=CEN.
GEODOMISI Ltd. - Dr. Costas Sachpazis

Section

Civil & Geotechnical Engineering Consulting Company for


Structural Engineering, Soil Mechanics, Rock Mechanics,
Foundation Engineering & Retaining Structures.
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 Mobile: (+30) 6936425722 & (+44) 7585939944,

www.geodomisi.com - costas@sachpazis.info

Sheet no./rev. 1

Civil & Geotechnical Engineering


Calc.
Dr. C. Sachpazis

Date
16/01/2016

Chk'd by
Date

App'd by

Date

DESCRIPTION
Calculation of the punching shear perimeters
Perimeter of the s
support (C1)
u0:

1600 mm

Critical perimeter
u1:

4362 mm

xG:

0 mm

yG:

0 mm

W1x:

19163.6 cm

W1y:

19163.6 cm

Punching shear reinforcement perimeter


uout,ef:

5031 mm

xG:

0 mm

yG:

0 mm

Wout,ef,x:

51487.8 cm

Wout,ef,y:

51487.8 cm

CHECKS
1.- Zone adjacent to the support or load (Persistent situations)
The worst case design forces occur for load combination 1.35SW+1.35DL1+1.5LL1.
The following criteria must be satisfied:
vEd vRd,max
2.43 MPa 4.50 MPa
Where:
vEd: Design value of the sheer stress along the control section considered.
vRd,max: Design value of the maximum punching shear resistance along the
control section considered.

vEd :

2.43

MPa

vRd,max :

4.50

MPa

vEd :

2.43

MPa

The design value of the sheer stress along the control section considered is obtained
from the following expression (EN 1992
1992-1-1:2004/AC:2008, 6.4.5):

vEd =

VEd
u0 d

Where:
VEd: Design value of the applied shear force.

VEd : 756.75 kN

Page 3 - 11

Project: VERIFICATION OF THE ULTIMATE PUNCHING Job Ref.


SHEAR RESISTANCE to EUROCODE2 1992-1-1:2004
www.geodomisi.com
with NA=CEN.
GEODOMISI Ltd. - Dr. Costas Sachpazis

Section

Civil & Geotechnical Engineering Consulting Company for


Structural Engineering, Soil Mechanics, Rock Mechanics,
Foundation Engineering & Retaining Structures.
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 Mobile: (+30) 6936425722 & (+44) 7585939944,

www.geodomisi.com - costas@sachpazis.info

Sheet no./rev. 1

Civil & Geotechnical Engineering


Calc.
Dr. C. Sachpazis

Date
16/01/2016

Chk'd by
Date

: Coefficient which takes into account the effects of load eccentricity. (EN
1992-1-1:2004/AC:2008, 6.4.3).

= 1 + kx

MEdx
VEd

App'd by

Date

1.13

kx :

0.60

ky :

0.60

MEdy u1
u1
+ ky

W1x
VEd W1y

kx: Coefficient which depends on the relationship between the dimensions


cy (dimension in direction of the y-axis) and cx (dimension in direction of the
x-axis) of the column (EN 1992-1-1:2004/AC:2008, Table 6.1).
ky: Coefficient which depends on the relationship between the dimensions cx
(dimension in direction of the x-axis) and cy (dimension in direction of the
y-axis) of the column (EN 1992-1-1:2004/AC:2008, Table 6.1).
MEdx: Design moment around the x-axis, regarding the center of gravity of
the critical perimeter u1.
MEdy: Design moment around the y-axis, regarding the center of gravity of
the critical perimeter u1.
MEdOx: Design moment around the x-axis, regarding the center of gravity of
the column.
MEdOy: Design moment around the y-axis, regarding the center of gravity of
the column.
u1: Critical punching shear perimeter (EN 1992-1-1:2004/AC:2008, 6.4.2).

MEdx :

58.65

kNm

MEdy :

12.30

kNm

MEdOx :

58.65

kNm

MEdOy :

12.30

kNm

u1 :

4362

mm

u1

W1x =

dl

W1x : 19163.6 cm

dl: Differential element of the critical perimeter length.


ey: Distance from dl to the axis where the moment MEdx acts about.
u1

W1y =

dl

W1y : 19163.6 cm

ex: Distance from dl to the axis where the moment MEdy acts about.
u0: Verification critical punching shear perimeter of the area adjacent to the
support or load (EN 1992-1-1:2004/AC:2008, 6.4.5).

u0 :

1600

mm

d:

220

mm

vRd,max = 0.5 fcd

vRd,max :

4.50

MPa

= 0.6 1 ck
250

0.54

d: Nominal depth of the slab.


The design value of the maximum punching shear resistance along the control section
considered is obtained from the following expression (EN 1992-1-1:2004/AC:2008,
6.4.5):

Where:
fck: Concrete compressive strength.

fck :

25.00

MPa

Page 4 - 11

Project: VERIFICATION OF THE ULTIMATE PUNCHING Job Ref.


SHEAR RESISTANCE to EUROCODE2 1992--1-1:2004
www.geodomisi.com
with NA=CEN.
GEODOMISI Ltd. - Dr. Costas Sachpazis

Section

Civil & Geotechnical Engineering Consulting Company for


Structural Engineering, Soil Mechanics, Rock Mechanics,
Foundation Engineering & Retaining Structures.
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 Mobile: (+30) 6936425722 & (+44) 7585939944,

www.geodomisi.com - costas@sachpazis.info

Sheet no./rev. 1

Civil & Geotechnical Engineering


Calc.
Dr. C. Sachpazis

Date
16/01/2016

Chk'd by
Date

fcd: Design value of the concrete compression force in the direction of the
longitudinal member axis.

App'd by

fcd :

Date

16.67

MPa

2.- Zone with punching shear reinforcement (Persistent situations)


The worst case design forces occur for load combination 1.35SW+1.35DL1+1.5LL1.
The following criteria must be satisfied:
vEd vRd,cs
0.89 MPa 4.90 MPa
Where:
vEd: Design value of the sheer stress along the control section considered.
vRd,cs: Design value of the punching shear resistance of a slab with punching
shear reinforcement along the control section cons
considered.

vEd :

0.89

MPa

vRd,cs :

4.90

MPa

vEd :

0.89

MPa

The design value of the sheer stress along the control section considered is obtained
from the following expression (EN 1992
1992-1-1:2004/AC:2008, 6.4.3):

vEd =

VEd
u1 d

Where:
VEd: Design value of the applied shear force.
: Coefficient which takes into account the effects of load eccentricity. (EN
1992-1-1:2004/AC:2008,
1:2004/AC:2008, 6.4.3).

= 1 + kx

MEdx
VEd

VEd : 756.75 kN
:

1.13

kx :

0.60

ky :

0.60

MEdy u1
u1
+ ky

W1x
VEd W1y

kx: Coefficient which depends on the relationship between the dimensions


cy (dimension in direction of the y-axis)
y
and cx (dimension in direction of
the x-axis)
axis) of the column (EN 1992
1992-1-1:2004/AC:2008, Table 6.1).
ky: Coefficient which depends on the relationship between the dimensions
cx (dimension in direction of the x-axis)
x
and cy (dimension in direction
on of
the y-axis)
axis) of the column (EN 1992
1992-1-1:2004/AC:2008, Table 6.1).
MEdx: Design moment around the x-axis,
x axis, regarding the center of gravity of
the critical perimeter u1.
MEdy: Design moment around the y-axis,
y
regarding
ng the center of gravity of
the critical perimeter u1.
MEdOx: Design moment around the x
x-axis,
axis, regarding the center of gravity
of the column.
MEdOy: Design moment around the y-axis,
y
regarding the center of gravity
of the column.
u1: Critical punching shear perimeter (EN 1992
1992-1-1:2004/AC:2008,
1:2004/AC:2008, 6.4.2).

MEdx :

58.65

kNm

MEdy :

12.30

kNm

MEdOx :

58.65

kNm

MEdOy :
u1 :

12.30
4362

kNm
mm

u1

W1x =

dl

W1x : 19163.6 cm

dl:: Differential element of the critical perimeter length.


Page 5 - 11

Project: VERIFICATION OF THE ULTIMATE PUNCHING Job Ref.


SHEAR RESISTANCE to EUROCODE2 1992-1-1:2004
www.geodomisi.com
with NA=CEN.
GEODOMISI Ltd. - Dr. Costas Sachpazis

Section

Civil & Geotechnical Engineering Consulting Company for


Structural Engineering, Soil Mechanics, Rock Mechanics,
Foundation Engineering & Retaining Structures.
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 Mobile: (+30) 6936425722 & (+44) 7585939944,

www.geodomisi.com - costas@sachpazis.info

Sheet no./rev. 1

Civil & Geotechnical Engineering


Calc.
Dr. C. Sachpazis

Date
16/01/2016

Chk'd by
Date

App'd by

Date

ey: Distance from dl to the axis where the moment MEdx acts about.
u1

W1y =

dl

W1y : 19163.6 cm

ex: Distance from dl to the axis where the moment MEdy acts about.
d: Nominal depth of the slab.

d:

220

mm

vRd,cs :

4.90

MPa

vRd,c :

0.95

MPa

vRd,c,min :

0.68

MPa

c :
k:

1.50
1.95

fck :

25.00

The design value of the punching shear resistance of a slab with punching shear
reinforcement along the control section considered is obtained from the following
expression (EN 1992-1-1:2004/AC:2008, 6.4.5):

A sw

fywd,ef sin
sr

vRd,cs = 0.75 vRd,c + 1.5

u1

Where:

vRd,c =

0.18
1/3
k (100 l fck )
+ 0.1 cp
c

with a minimum value of:


1/2
vRd,c,min = 0.035 k 3 / 2 fck
+ 0.1 cp

Where:
c: Concrete resistance reduction coefficient.
k: Coefficient which depends on the nominal depth of 'd'.

200
k = 1 +
2

fck: Concrete compressive strength.


l: Geometric steel area of the main tensile longitudinal
reinforcement.

l =

MPa

l : 0.0132

lx ly 0.02

Where:
lx: Ratio in X-direction.
ly: Ratio in Y-direction.
cp: Average axial stress on the critical verification surface (positive
compression), with a maximum value of cp,max.

cp,max = 0.20 fcd


fcd: Design value of the concrete compression force in the
direction of the longitudinal member axis.

lx : 0.0132
ly : 0.0132
cp :

2.00

MPa

cp,max :

3.33

MPa

16.67

MPa

fcd :

Page 6 - 11

Project: VERIFICATION OF THE ULTIMATE PUNCHING Job Ref.


SHEAR RESISTANCE to EUROCODE2 1992--1-1:2004
www.geodomisi.com
with NA=CEN.
GEODOMISI Ltd. - Dr. Costas Sachpazis

Section

Civil & Geotechnical Engineering Consulting Company for


Structural Engineering, Soil Mechanics, Rock Mechanics,
Foundation Engineering & Retaining Structures.
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 Mobile: (+30) 6936425722 & (+44) 7585939944,

www.geodomisi.com - costas@sachpazis.info

Sheet no./rev. 1

Civil & Geotechnical Engineering


Calc.
Dr. C. Sachpazis

Date
16/01/2016

Chk'd by
Date

App'd by

Date

Asw: Total area of punching shear reinforcement within a permieter


concentric with the support or loaded area.
sr: Radial distance between two concentric perimeters of reinforcement.
reinforcement.
: Angle between the shear reinforcement and the plane of the slab.
Asw
(mm)

sr
(mm)

(degrees)

Asw/sr
(cm/m)

111

2262

80

45.0

282.8

111

2262

80

45.0

282.8

Reference

fywd,ef: Effective design strength of the punching shear reinforcement.

fywd,ef : 305.00 MPa

fywd,ef = 250 + 0.25 d fywd


fywd: Design yield strength of the shear reinforcement.

fywd = 0.8 fywk

fywd : 320.00 MPa

(EN 1992-1-1:2004/AC:2008,
1:2004/AC:2008, 6.2.3(3))
fywk : 400.00 MPa
u1: Critical punching shear perimeter (EN 1992
1992-1-1:2004/AC:2008, 6.4.2).

u1 : 4362 mm

3.- External zone to the punching shear reinforecement (Persistent situations)


The worst case design forces occur for load combination 1.35SW+1.35DL1+1.5LL1.
The following criteria must be satisfied:
vEd vRd,c
0.72 MPa 0.95 MPa
Where:
vEd: Design value of the sheer stress along the control section considered.
vRd,c: Design value of the punching shear resistance of a slab without punching
shear reinforcement
nt along the control section considered.

vEd :

0.72

MPa

vRd,c :

0.95

MPa

vEd :

0.72

MPa

The design value of the sheer stress along the control section considered is obtained
from the following expression (EN 1992
1992-1-1:2004/AC:2008, 6.4.5):

vEd =

VEd
uout,ef d

Where:
VEd: Design value of the applied shear force.
: Coefficient which takes into account the effects of load eccentricity. (EN
1992-1-1:2004/AC:2008,
1:2004/AC:2008, 6.4.3).

= 1 + kx

MEdx
VEd

uout,ef
Wout,ef,x

+ ky

MEdy
VEd

VEd : 756.75 kN
:

1.05

uout,ef
Wout,ef,y
Page 7 - 11

Project: VERIFICATION OF THE ULTIMATE PUNCHING Job Ref.


SHEAR RESISTANCE to EUROCODE2 1992-1-1:2004
www.geodomisi.com
with NA=CEN.
GEODOMISI Ltd. - Dr. Costas Sachpazis

Section

Civil & Geotechnical Engineering Consulting Company for


Structural Engineering, Soil Mechanics, Rock Mechanics,
Foundation Engineering & Retaining Structures.
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 Mobile: (+30) 6936425722 & (+44) 7585939944,

www.geodomisi.com - costas@sachpazis.info

Sheet no./rev. 1

Civil & Geotechnical Engineering


Calc.
Dr. C. Sachpazis

Date
16/01/2016

Chk'd by
Date

kx: Coefficient which depends on the relationship between the dimensions


cy (dimension in direction of the y-axis) and cx (dimension in direction of
the x-axis) of the column (EN 1992-1-1:2004/AC:2008, Table 6.1).
ky: Coefficient which depends on the relationship between the dimensions
cx (dimension in direction of the x-axis) and cy (dimension in direction of
the y-axis) of the column (EN 1992-1-1:2004/AC:2008, Table 6.1).
MEdx: Design moment around the x-axis, regarding the center of gravity of
the critical perimeter uout,ef.
MEdy: Design moment around the y-axis, regarding the center of gravity of
the critical perimeter uout,ef.
MEdOx: Design moment around the x-axis, regarding the center of gravity
of the column.
MEdOy: Design moment around the y-axis, regarding the center of gravity
of the column.
uout,ef: Critical punching shear perimeter outside the reinforced zone (EN
1992-1-1:2004/AC:2008, 6.4.5).

App'd by

Date

kx :

0.60

ky :

0.60

MEdx :

58.65

kNm

MEdy :

12.30

kNm

MEdOx :

58.65

kNm

MEdOy :

12.30

kNm

uout,ef :

5031

mm

uout,ef

Wout,ef,x =

ey dl

Wout,ef,x : 51487.8 cm

dl: Differential element of the critical perimeter length.


ey: Distance from dl to the axis where the moment MEdx acts about.
uout,ef

Wout,ef,y =

ex dl

Wout,ef,y : 51487.8 cm

ex: Distance from dl to the axis where the moment MEdy acts about.
d: Nominal depth of the slab.

d:

220

mm

vRd,c :

0.95

MPa

vRd,c,min :

0.68

MPa

c :
k:

1.50
1.95

The design value of the punching shear resistance of a slab without punching shear
reinformcement along the control section considered is obtained from the following
expression (EN 1992-1-1:2004/AC:2008, 6.4.4):

vRd,c =

0.18
1/3
k (100 l fck )
+ 0.1 cp
c

with a minimum value of:


1/2
vRd,c,min = 0.035 k 3 / 2 fck
+ 0.1 cp

Where:
c: Concrete resistance reduction coefficient.
k: Coefficient which depends on the nominal depth of 'd'.

k = 1 +

200
2
d

fck: Concrete compressive strength.


l: Geometric steel area of the main tensile longitudinal reinforcement.

fck : 25.00 MPa


l : 0.0132
Page 8 - 11

Project: VERIFICATION OF THE ULTIMATE PUNCHING Job Ref.


SHEAR RESISTANCE to EUROCODE2 1992--1-1:2004
www.geodomisi.com
with NA=CEN.
GEODOMISI Ltd. - Dr. Costas Sachpazis

Section

Civil & Geotechnical Engineering Consulting Company for


Structural Engineering, Soil Mechanics, Rock Mechanics,
Foundation Engineering & Retaining Structures.
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 Mobile: (+30) 6936425722 & (+44) 7585939944,

www.geodomisi.com - costas@sachpazis.info

Sheet no./rev. 1

Civil & Geotechnical Engineering


Calc.
Dr. C. Sachpazis

Date
16/01/2016

Chk'd by
Date

App'd by

Date

l = lx ly 0.02
Where:
lx: Ratio in X--direction.
ly: Ratio in Y--direction.

lx : 0.0132
ly : 0.0132

cp: Average axial stress on the critical verification surface (positive


compression), with a maximum value of cp,max.

cp,max = 0.20 fcd


fcd: Design value of the concrete compression for
force
ce in the direction of
the longitudinal member axis.

cp :

2.00

MPa

cp,max :

3.33

MPa

16.67

MPa

fcd :

4.- Punching shear reinforcement (EN 1992


1992-1-1:2004/AC:2008,
1:2004/AC:2008, 9.4.3(2))
Where shear reinforcement is required the area of a link leg (or equivalent), Asw,min, is given by Expression
(9.11).

Asw,min (1,5 sin + cos ) / ( sr st ) 0,08

( fck ) / f yk

( 9.11)

w = Asw,min (1,5 sin + cos ) / ( sr st )


w,min = 0, 08

( fck ) / f yk
Asw
(mm)

sr
(mm)

st
(mm)

(degrees)

w,min

111

113

80

33

45.0

0.0757

0.0010

111

113

80

33

45.0

0.0757

0.0010

Reference

w w,min

where:
Asw: the area of a link leg (or equivalent).
: is the angle between the shear reinforcement and the main steel (i.e. for
for vertical links
= 90 and sin = 1).
sr: is the spacing of shear links in the radial direction.
st: is the spacing of shear links in the tangential direction.
fck: is in MPa

fck : 25.00 MPa

5.- Clear distance between two isolated consecutive bars


The horizontal and vertical clear spacing dl between two consecutive bars should be greater than or equal to
smin (EN 1992-1-1:2004/AC:2008,
1:2004/AC:2008, 8.2(2)):
dl smin
21 mm 20 mm
Page 9 - 11

Project: VERIFICATION OF THE ULTIMATE PUNCHING Job Ref.


SHEAR RESISTANCE to EUROCODE2 1992--1-1:2004
www.geodomisi.com
with NA=CEN.
GEODOMISI Ltd. - Dr. Costas Sachpazis

Section

Civil & Geotechnical Engineering Consulting Company for


Structural Engineering, Soil Mechanics, Rock Mechanics,
Foundation Engineering & Retaining Structures.
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 Mobile: (+30) 6936425722 & (+44) 7585939944,

www.geodomisi.com - costas@sachpazis.info

Sheet no./rev. 1

Civil & Geotechnical Engineering


Calc.
Dr. C. Sachpazis

Date
16/01/2016

Chk'd by
Date

App'd by

Date

Where:
smin: Maximum value of s1, s2, s3.

smin : 20 mm

s1 = max

s1 : 12 mm

s2 = 5 + dg

s2 : 17 mm

s3 = 20mm

s3 : 20 mm

Where:
dg: Maximum size of aggregate.
max: Diameter of the thickest bar of the transverse reinforcement.

dl
(mm)

smin
(mm)

max
(mm)

111

21

20

12

111

21

20

12

dg : 12 mm
max : 12 mm

6.- Distance between the support's face and the first punching shear reinforcement
The distance between the face of the support or loaded area and the first punching shear rreinforcement should
not be greater than smax (EN 1992--1-1:2004/AC:2008, 9.4.3):
dl smax
80 mm 110 mm
Where:

smax = 0.5 d
d:: Nominal depth of the slab.

smax : 110 mm
d : 220 mm

7.- Distance between transverse consecutive reinforcement


reinforcemen perimeters
The distance dl between consecutive transverse reinforcement perimeters should be, at most, equal to smax (EN
1992-1-1:2004/AC:2008, 9.4.3):
dl smax
80 mm 165 mm
Where:
Page 10 - 11

Project: VERIFICATION OF THE ULTIMATE PUNCHING Job Ref.


SHEAR RESISTANCE to EUROCODE2 1992--1-1:2004
www.geodomisi.com
with NA=CEN.
GEODOMISI Ltd. - Dr. Costas Sachpazis

Section

Civil & Geotechnical Engineering Consulting Company for


Structural Engineering, Soil Mechanics, Rock Mechanics,
Foundation Engineering & Retaining Structures.
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 Mobile: (+30) 6936425722 & (+44) 7585939944,

www.geodomisi.com - costas@sachpazis.info

Sheet no./rev. 1

Civil & Geotechnical Engineering


Calc.
Dr. C. Sachpazis

Date
16/01/2016

Chk'd by
Date

smax = 0.75 d

App'd by

Date

smax : 165 mm

d:: Nominal depth of the slab.

d : 220 mm

8.- Distance between two consecutive reinforcements in peripheral direction


The distance dl between two consecutive perimeter reinforcements should not be greater than smax (EN 19921-1:2004/AC:2008, 9.4.3):
dl smax
33 mm 330 mm
Where:

smax = 1.5 d

smax : 330 mm

d:: Nominal depth of the slab.

d : 220 mm

9.- Distance between the support's external face and the outermost bar inclined at 45
This combination does not proceed since the reinforcement is located
located between the external faces of the
support.

GEODOMISI Ltd. - Dr. Costas Sachpazis


Civil & Geotechnical Engineering Consulting Company for
Structural Engineering, Soil Mechanics, Rock Mechanics, Foundation
Engineering & Retaining Structures.
Tel.: (+30) 210 5238127, 210 5711263 - Fax.:+30 210 5711461 - Mobile:
(+30) 6936425722 & (+44) 7585939944,

www.geodomisi.com - costas@sachpazis.info
Page 11 - 11