www.geodomisi.com
- costas@sachpazis.info
Section
www.geodomisi.com - costas@sachpazis.info
Sheet no./rev. 1
Date
16/01/2016
Chk'd by
Date
App'd by
Date
INDEX
DESCRIPTION
CHECKS
1.- Zone adjacent to the support or load (Persistent situations)
2.- Zone with punching shear reinforcement (Persistent situations)
3
5
to
the
punching
shear
reinforecement
(Persistent
9
9
6.- Distance between the support's face and the first punching shear
reinforcement
10
7.- Distance between transverse consecutive reinforcement perimeters
10
Section
www.geodomisi.com - costas@sachpazis.info
Sheet no./rev. 1
Date
16/01/2016
Chk'd by
Date
App'd by
Date
DESCRIPTION
Calculation of the punching shear perimeters
Perimeter of the s
support (C1)
u0:
1600 mm
Critical perimeter
u1:
4362 mm
xG:
0 mm
yG:
0 mm
W1x:
19163.6 cm
W1y:
19163.6 cm
5031 mm
xG:
0 mm
yG:
0 mm
Wout,ef,x:
51487.8 cm
Wout,ef,y:
51487.8 cm
CHECKS
1.- Zone adjacent to the support or load (Persistent situations)
The worst case design forces occur for load combination 1.35SW+1.35DL1+1.5LL1.
The following criteria must be satisfied:
vEd vRd,max
2.43 MPa 4.50 MPa
Where:
vEd: Design value of the sheer stress along the control section considered.
vRd,max: Design value of the maximum punching shear resistance along the
control section considered.
vEd :
2.43
MPa
vRd,max :
4.50
MPa
vEd :
2.43
MPa
The design value of the sheer stress along the control section considered is obtained
from the following expression (EN 1992
1992-1-1:2004/AC:2008, 6.4.5):
vEd =
VEd
u0 d
Where:
VEd: Design value of the applied shear force.
VEd : 756.75 kN
Page 3 - 11
Section
www.geodomisi.com - costas@sachpazis.info
Sheet no./rev. 1
Date
16/01/2016
Chk'd by
Date
: Coefficient which takes into account the effects of load eccentricity. (EN
1992-1-1:2004/AC:2008, 6.4.3).
= 1 + kx
MEdx
VEd
App'd by
Date
1.13
kx :
0.60
ky :
0.60
MEdy u1
u1
+ ky
W1x
VEd W1y
MEdx :
58.65
kNm
MEdy :
12.30
kNm
MEdOx :
58.65
kNm
MEdOy :
12.30
kNm
u1 :
4362
mm
u1
W1x =
dl
W1x : 19163.6 cm
W1y =
dl
W1y : 19163.6 cm
ex: Distance from dl to the axis where the moment MEdy acts about.
u0: Verification critical punching shear perimeter of the area adjacent to the
support or load (EN 1992-1-1:2004/AC:2008, 6.4.5).
u0 :
1600
mm
d:
220
mm
vRd,max :
4.50
MPa
= 0.6 1 ck
250
0.54
Where:
fck: Concrete compressive strength.
fck :
25.00
MPa
Page 4 - 11
Section
www.geodomisi.com - costas@sachpazis.info
Sheet no./rev. 1
Date
16/01/2016
Chk'd by
Date
fcd: Design value of the concrete compression force in the direction of the
longitudinal member axis.
App'd by
fcd :
Date
16.67
MPa
vEd :
0.89
MPa
vRd,cs :
4.90
MPa
vEd :
0.89
MPa
The design value of the sheer stress along the control section considered is obtained
from the following expression (EN 1992
1992-1-1:2004/AC:2008, 6.4.3):
vEd =
VEd
u1 d
Where:
VEd: Design value of the applied shear force.
: Coefficient which takes into account the effects of load eccentricity. (EN
1992-1-1:2004/AC:2008,
1:2004/AC:2008, 6.4.3).
= 1 + kx
MEdx
VEd
VEd : 756.75 kN
:
1.13
kx :
0.60
ky :
0.60
MEdy u1
u1
+ ky
W1x
VEd W1y
MEdx :
58.65
kNm
MEdy :
12.30
kNm
MEdOx :
58.65
kNm
MEdOy :
u1 :
12.30
4362
kNm
mm
u1
W1x =
dl
W1x : 19163.6 cm
Section
www.geodomisi.com - costas@sachpazis.info
Sheet no./rev. 1
Date
16/01/2016
Chk'd by
Date
App'd by
Date
ey: Distance from dl to the axis where the moment MEdx acts about.
u1
W1y =
dl
W1y : 19163.6 cm
ex: Distance from dl to the axis where the moment MEdy acts about.
d: Nominal depth of the slab.
d:
220
mm
vRd,cs :
4.90
MPa
vRd,c :
0.95
MPa
vRd,c,min :
0.68
MPa
c :
k:
1.50
1.95
fck :
25.00
The design value of the punching shear resistance of a slab with punching shear
reinforcement along the control section considered is obtained from the following
expression (EN 1992-1-1:2004/AC:2008, 6.4.5):
A sw
fywd,ef sin
sr
u1
Where:
vRd,c =
0.18
1/3
k (100 l fck )
+ 0.1 cp
c
Where:
c: Concrete resistance reduction coefficient.
k: Coefficient which depends on the nominal depth of 'd'.
200
k = 1 +
2
l =
MPa
l : 0.0132
lx ly 0.02
Where:
lx: Ratio in X-direction.
ly: Ratio in Y-direction.
cp: Average axial stress on the critical verification surface (positive
compression), with a maximum value of cp,max.
lx : 0.0132
ly : 0.0132
cp :
2.00
MPa
cp,max :
3.33
MPa
16.67
MPa
fcd :
Page 6 - 11
Section
www.geodomisi.com - costas@sachpazis.info
Sheet no./rev. 1
Date
16/01/2016
Chk'd by
Date
App'd by
Date
sr
(mm)
(degrees)
Asw/sr
(cm/m)
111
2262
80
45.0
282.8
111
2262
80
45.0
282.8
Reference
(EN 1992-1-1:2004/AC:2008,
1:2004/AC:2008, 6.2.3(3))
fywk : 400.00 MPa
u1: Critical punching shear perimeter (EN 1992
1992-1-1:2004/AC:2008, 6.4.2).
u1 : 4362 mm
vEd :
0.72
MPa
vRd,c :
0.95
MPa
vEd :
0.72
MPa
The design value of the sheer stress along the control section considered is obtained
from the following expression (EN 1992
1992-1-1:2004/AC:2008, 6.4.5):
vEd =
VEd
uout,ef d
Where:
VEd: Design value of the applied shear force.
: Coefficient which takes into account the effects of load eccentricity. (EN
1992-1-1:2004/AC:2008,
1:2004/AC:2008, 6.4.3).
= 1 + kx
MEdx
VEd
uout,ef
Wout,ef,x
+ ky
MEdy
VEd
VEd : 756.75 kN
:
1.05
uout,ef
Wout,ef,y
Page 7 - 11
Section
www.geodomisi.com - costas@sachpazis.info
Sheet no./rev. 1
Date
16/01/2016
Chk'd by
Date
App'd by
Date
kx :
0.60
ky :
0.60
MEdx :
58.65
kNm
MEdy :
12.30
kNm
MEdOx :
58.65
kNm
MEdOy :
12.30
kNm
uout,ef :
5031
mm
uout,ef
Wout,ef,x =
ey dl
Wout,ef,x : 51487.8 cm
Wout,ef,y =
ex dl
Wout,ef,y : 51487.8 cm
ex: Distance from dl to the axis where the moment MEdy acts about.
d: Nominal depth of the slab.
d:
220
mm
vRd,c :
0.95
MPa
vRd,c,min :
0.68
MPa
c :
k:
1.50
1.95
The design value of the punching shear resistance of a slab without punching shear
reinformcement along the control section considered is obtained from the following
expression (EN 1992-1-1:2004/AC:2008, 6.4.4):
vRd,c =
0.18
1/3
k (100 l fck )
+ 0.1 cp
c
Where:
c: Concrete resistance reduction coefficient.
k: Coefficient which depends on the nominal depth of 'd'.
k = 1 +
200
2
d
Section
www.geodomisi.com - costas@sachpazis.info
Sheet no./rev. 1
Date
16/01/2016
Chk'd by
Date
App'd by
Date
l = lx ly 0.02
Where:
lx: Ratio in X--direction.
ly: Ratio in Y--direction.
lx : 0.0132
ly : 0.0132
cp :
2.00
MPa
cp,max :
3.33
MPa
16.67
MPa
fcd :
( fck ) / f yk
( 9.11)
( fck ) / f yk
Asw
(mm)
sr
(mm)
st
(mm)
(degrees)
w,min
111
113
80
33
45.0
0.0757
0.0010
111
113
80
33
45.0
0.0757
0.0010
Reference
w w,min
where:
Asw: the area of a link leg (or equivalent).
: is the angle between the shear reinforcement and the main steel (i.e. for
for vertical links
= 90 and sin = 1).
sr: is the spacing of shear links in the radial direction.
st: is the spacing of shear links in the tangential direction.
fck: is in MPa
Section
www.geodomisi.com - costas@sachpazis.info
Sheet no./rev. 1
Date
16/01/2016
Chk'd by
Date
App'd by
Date
Where:
smin: Maximum value of s1, s2, s3.
smin : 20 mm
s1 = max
s1 : 12 mm
s2 = 5 + dg
s2 : 17 mm
s3 = 20mm
s3 : 20 mm
Where:
dg: Maximum size of aggregate.
max: Diameter of the thickest bar of the transverse reinforcement.
dl
(mm)
smin
(mm)
max
(mm)
111
21
20
12
111
21
20
12
dg : 12 mm
max : 12 mm
6.- Distance between the support's face and the first punching shear reinforcement
The distance between the face of the support or loaded area and the first punching shear rreinforcement should
not be greater than smax (EN 1992--1-1:2004/AC:2008, 9.4.3):
dl smax
80 mm 110 mm
Where:
smax = 0.5 d
d:: Nominal depth of the slab.
smax : 110 mm
d : 220 mm
Section
www.geodomisi.com - costas@sachpazis.info
Sheet no./rev. 1
Date
16/01/2016
Chk'd by
Date
smax = 0.75 d
App'd by
Date
smax : 165 mm
d : 220 mm
smax = 1.5 d
smax : 330 mm
d : 220 mm
9.- Distance between the support's external face and the outermost bar inclined at 45
This combination does not proceed since the reinforcement is located
located between the external faces of the
support.
www.geodomisi.com - costas@sachpazis.info
Page 11 - 11