NALCO 77225

INTERNAL BOILER TREATMENT


Product Bulletin

PRODUCT DESCRIPTION AND APPLICATION


NALCO 77225 is a boiler feedwater treatment for scale control, achieved through a combination of a phosphate residual
programme and Transport Plus polymer technology. It can be used as a phosphate treatment for low hardness, softened
and/or dealkalized feed waters in boilers operating at pressures up to 40 barg. The complex phosphate reacts with calcium
and magnesium, while the organic polymer provides transport of the calcium, magnesium, iron, phosphate and silica
through the boiler. The formation of adherent deposits is prevented, thus increasing steam production runs, reducing the
danger of tube overheating and lessening the outage time for boiler cleaning.

PHYSICAL & CHEMICAL PROPERTIES


These properties are typical. Refer to the Material Safety Data Sheet (MSDS), SECTION 9, for the most current data.
Form

Liquid

Colour :

Light Yellow

Odour :

Ammoniacal

Flash Point

None

Relative Density (25 C, 77 F) :


Solubility in water
pH

1.46 - 1.50

Complete

>13

Viscosity

8-16 cps

Freeze Point

< -20 C ( < -4 F)

ACTIVE CONSTITUENTS
The active constituents are considered to be proprietary information for this product.

REGULATORY APPROVALS
When use situations necessitate (Check with Plant Manager or Process Area Superintendent), NALCO 77225 is in
compliance with the United States Food & Drugs Administration (F.D.A.) regulations pertaining to Boiler Water Additives (21
CFR 173.310).

MATERIALS OF COMPATIBILITY

Compatible

Not Compatible

Stainless steel

Aluminium

Polyethylene

Copper

Polypropylene

Brass

PVC

Zinc

Nylon

Light alloys

Viton

Natural Rubber

Buna-N

Avoid the use of PTFE as a shaft or plunger seal

Neoprene

in contact with stainless steel

EPDM
Butyl Rubber
Nitrite Rubber
CAF and PTFE

DOSAGE AND FEEDING


The dosage of NALCO 77225 will vary depending on the water quality and boiler pressure. Exact dosage requirements will
be determined by your on-site Nalco representative.
Consequences of overfeed
Overfeed of NALCO 77225 will result in high chemical costs. Excessive feed will also contribute high boiler water solids and
phosphate values, which will require excessive blowdown to keep the program in control.
Consequences of underfeed
Underfeed of Nalco 77225 will result in an excursion from proper co-ordinated phosphate-pH control parameters. Being
outside of proper control parameters can lead to rapid boiler system scaling and/or corrosion.

ENVIRONMENTAL AND TOXICITY DATA


Refer to the Material Safety Data Sheet, Section 11 for toxicology information (Aquatic and mammalian toxicity) and Section
12 for environmental information.

SAFETY AND HANDLING


NALCO 77225 is an alkaline product. Always use personal protective equipment (PPE) when handling neat or dilute
product.
Read the label and Material Safety Data Sheet for complete handling information before using this product.

STORAGE
NALCO 77225 maximum storage temperature is 65 C (149 F).Storing at higher temperatures for prolonged periods may
lead to a white precipitate being formed. Recommended storage limit in unopened containers is 6 months after receipt.

REMARKS
If you need assistance or more information on this product, please call your nearest Nalco Representative. For more news
about Nalco Company, visit our website at www.nalco.com.
For Medical and Transportation Emergencies involving Nalco products, please see the Material Safety Data Sheet for the
phone number.

ADDITIONAL INFORMATION
NALCO is a registered trademark of Nalco Company (8/5/05)

Nalco Company, 1601 West Diehl Road, Naperville, Illinois 60563-1198


Subsidiaries and Affiliates in Principal Locations Around the World
2010 Nalco Company All Rights Reserved