PUNCHING SHEAR CALCULATION

AS PER IS:456 (WITH UNBALANCED MOMENTS)

PROJECT: NAHARS'S AMRIT DESIGNER: THILAHAR

FLOOR: PODIUM FLOOR DATE: 31.12.09

UTRACON Structural Systems Pvt. Ltd. LOCATION: SHEET NO: 1

Available Datas:-

Depth of slab = 300 mm

Depth of drop = 575 mm

Width of column (C1) = 300 mm

Breadth of column (C2) = 900 mm

Grade of concrete = 35 mm

Grade of steel = 415 N/mm²

Unbalanced Moments ,Mt xx (From RAPT) = 50 kN-m

Unbalanced Moments ,Mt yy (From RAPT) = 10 kN-m

Total factored shear force, ( V ) (From RAPT) = 1696 kN

Calulations:-

Effective depth at critical section (d) = 530 mm

Width of critical section (a) = 565 mm

Bredth of critial section (b) = 1430 mm

Perimeter of critical section (p) = 2560 mm

C = 124.70 mm

Polar moment of inertia (Jxx) = 5.66E+10 mm4

Moment transferred as shear = 29.53 %

29.53 % of 60 (Mt) = 1.77E+07 N-mm


Nominal shear stress (τv) = V (Mxx+Myy) X C
pXd Jxx

= 1.25 0.04

Nominal shear stress (τv) = 1.29 N/mm²

Permissible shear stress (τc) = 0.25√ƒck

= 1.48 N/mm²

Nominal Stress < Permissible stress

Hence Shear Reinforcement not Required