SERVICE BULLETIN
DATE: October 23, 2006
ACTUATOR
FOR
Electronic
Engine
Controller
Figure 1
The electronic governing system consists of a rotary actuator, which replaces the
standard governor cover, plus engine mounted electronic controls. The Woodward
Governor Company manufactures several variants of the DYNA 70025 pump mounted
electronic actuator. However, only three are available from Stanadyne - two 12 volt
actuators (internally sealed actuator shaft and non-sealed shaft versions) and one 24
volt actuator (sealed actuator shaft) version, as shown in the table in the following
page.
Stanadyne Corporation
92 Deerfield Road, Windsor, CT 06095, U.S.A.
-2-
S.B. 483R4
Stanadyne
Part Number
Actuator
Voltage
Type
Customer
33824
DYNC-70025-000-0-12
DYNC-70025-000-1-12
DYNC-70025-000-0-12
DYNC-70025-001-1-12
DYNC-70025-003-1-12
DC 70025-003-012
DC 70025-003-112
12
Sealed
Cummins
33825
DYNC-70025-000-0-24
DYNC-70025-000-1-24
DYNC-70025-001-0-24
DYNC-70025-001-1-24
DYNC-70025-003-1-24
DC 70025-003-024
DC 70025-003-124
24
Sealed
Cummins
34796
DYNC-70025-200-2-12
DYNC-70025-201-2-12
DC 70025-201-212
12
Standard
Perkins
-3-
S.B. 483R4
3. With the pump operating and fuel flowing out the return, turn the voltage
supply on. This will rotate the actuator out of contact with the linkage hook
thereby allowing full wide open throttle (WOT) fuel delivery.
4. Check the pump performance per the individual specification. In order to
perform the fuel delivery shutoff checks, de-energize the actuator.
NOTE: It will be necessary to reset the high idle settings to specification prior to
checking pump performance. In addition, the low idle setting procedure stated on
the individual service specification must also be carefully followed to prevent
possible mechanical interference between the throttle lever fork and the actuator
yoke when the throttle is in the low idle position.
Cover and Integrated
Actuator Assembly
Actuator Yoke
Governor
Linkage
Electrical
Terminals
Actuator Yoke
Figure 3
Governor Linkage
Care must be taken when reinstalling the Barber-Colman actuator to the pump.
With the mounting screws removed from the cover assembly, position and align
the actuator above and to the front of the pump and align the actuator yoke with
the linkage in the pump. Lower the actuator onto the pump at an angle as shown
in Figure 3. With the linkage properly engaged, a slight amount of pressure will
be required to align the cover holes. Reinstall the cover screws and tighten to
35-45 lbf. inches (4.0 - 5.1 N-m).
IMPORTANT: Once the pump is installed on the engine, it will be necessary to
reset the mechanical governor cutoff speed to a level that is 12% higher than the
desired operating speed controlled by the Barber-Colman actuator. This prevents
the mechanical governor from interfering with the electronic governor during
operation as well as providing overspeed protection.
-4-
S.B. 483R4
Warranty
Stanadynes limited warranty applies to pumps with Woodward/ Barber Colman
actuators as follows:
1. All models listed below that were originally equipped with DYNC 70025
actuators - both the pump and actuator are covered by our standard terms as
outlined in the Service Policies and Procedures Manual (99666) for the
specific application.
2. Pump models not listed below that have had a DYNC 70025 actuator added
in the field - the pump itself is covered by our standard warranty terms as
outlined in the Service Policies and Procedures Manual but the DYNC 70025
actuator does not qualify for the Stanadyne warranty coverage.
3. Service Parts Warranty - All DYNC 70025 actuators sold by Stanadyne
qualify for our Standard Service Parts warranty coverage of 12 months or 500
hours, whichever occurs first.
Pump Models Originally Equipped With a DYNC 70025 Actuator
33824 (12 Volt)
DB4427-5270
DB4427-5454
DB4627-5683
DB4629-5845
DB4427-5446
DB4627-5460
DB4627-5762
DB4427-5851
DB4427-5450
DB4627-5464
DB4427-5817
DB4427-5451
DB4627-5461
DB4427-5852
DB4427-5447
DB4427-5455
DB4627-5465
DB4629-5889
DB4627-5786
DB4627-5989
DB4627-5671
DB4627-5787
DB4627-5990
DB4627-5785
DB4627-5811
DB4627-5991
Revision
Date
Changes
09/03
10/06