Product Data
4WCZ6036A through 4WCZ6060A
Single Packaged Convertible Heat Pump
16 SEER
3, 4 & 5 Ton
R-410A
2010 Trane
Contents
Optional Equipment Listing
General Data
Heater Data
SPEK Data
Performance Data
Cooling
Heating
Indoor Blower
12
14
16
Typical Wiring
18
Optional Equipment
20
Dimensional Data
25
Mechanical Specifications
31
Optional Equipment
] indicates accessories included)
OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [
Hinged Filter Access Door (4WCZ6036) 0 ......................................................................... BAYACCDOR1A[
Hinged Filter Access Door (4WCZ6048-060) 0 .................................................................. BAYACCDOR2A[
Roof Curb Full Perimeter (4WCZ6036A) 3 .......................................................................... BAYCURB050A[
Roof Curb Full Perimeter (4WCZ6048-060A) 3 ................................................................... BAYCURB051A[
Roof Curb Utility Extension Kit (BAYCURB050A) .................................................................... BAYUTIL101B[
Roof Curb Utility Extension Kit (BAYCURB051A) .................................................................... BAYUTIL102B[
0-25% Motorized Outside Air Damper (4WCZ6036) .......................................................... BAYDMPR101A[
0-25% Motorized Outside Air Damper (4WCZ6048-060) .................................................. BAYDMPR102A[
Outside Air Control for V.S. Economizer (4WCZ6036-060A) 9 ............................................ BAYOSAC001B[
0-25% Manual Fresh Air Damper (4WCZ6036A) 1. ............................................................. BAYOSAH001A[
0-25% Manual Fresh Air Damper (4WCZ6048-060A) 1. ...................................................... BAYOSAH002A[
16" Round Duct Adapter (2 per box) (4WCZ6036A) 6 ........................................................ BAYSQRD001A[
18" Round Duct Adapter (2 per box) (4WCZ6024-060A) 6 ................................................. BAYSQRD002A[
0-100% Mod Economizer w/Baro. Relief (4WCZ6036A) 124 .......................................... BAYECON103A[
0-100% Mod. Economizer w/Baro. Relief (4WCZ6048-060A) 124. ................................. BAYECON104A[
0-100% Horizontal Economizer (4WCZ6036A) 12 . .......................................................... BAYECON203A[
0-100% Horizontal Economizer (4WCZ6048-060A) 12 . ................................................... BAYECON204A[
Economizer Relay Kit (required for Heat Pump applications) ................................................ BAYRLAY006A[
Enthalpy Control for Economizer (solid state). ...................................................................... BAYENTH001A[
Remote Potentiometer (All-BAYECON***A) ............................................................................... BAYSTAT023[
1"-2" Filter Frame (4WCZ6036A) (20 x 25 filter not included) 1. .......................................... BAYFLTR101B[
1"-2" Filter Frame (4WCZ6048-060A) (20 x 20,20X18 filter not included) 1. ....................... BAYFLTR201B[
Evaporator Defrost Control (Low Ambient Cooling) Kit 5. ................................................... BAYLOAM011A[
Head Pressure Control (Low Ambient Cool) (208/240v) Kit 5. ........................................... BAYLOAM105A[
Crankcase Heater Scroll (4WCZ6036,048A1/3,060A1/3)(230v) 5. ..................................... BAYCCHT102A[
Crankcase Heater Scroll (4WCZ6036-060A3)(460v) 5. ....................................................... BAYCCHT404B[
Adapter Curb 4WCZ6036A to BAYCURB030,38 ................................................................ BAYADAP050A[
Adapter Curb 4WCZ6036A to BAYCURB033 ..................................................................... BAYADAP051A[
Adapter Curb 4WCZ6048-060A to BAYCURB030,38 ......................................................... BAYADAP052A[
Adapter Curb 4WCZ6048-060A to BAYCURB033 .............................................................. BAYADAP053A[
Adapter Curb 4WCZ6048-060A to BAYCURB034 .............................................................. BAYADAP054A[
12" Duct Shroud Covers Horizontal 4WCZ6036-060A7. .................................................... BAYCOVR112A[
18" Duct Shroud Covers Horizontal 4WCZ6036-060A 7. ................................................... BAYCOVR118A[
Extreme Condition Mounting Kit - All BAYCURB & BAYADAP ........................................... BAYEXMK001A[
Extreme Condition Mounting Kit - All BAYUTIL .................................................................... BAYEXMK002A[
Extreme Condition Mounting Kit - All Slab Mounts ............................................................... BAYEXMK003A[
Lifting Lug Kit BAYLlFT002B[ ]
SUPPLEMENTARY HEATERS (1 PHASE)
3.76/5.00 KW Heater (208/240V 1PH) (4WCZ6036-060A1) ................................................ BAYHTRV105E[
6.00/8.00 KW Heater (208/240V 1PH( (4WCZ6036-060A1) ................................................. BAYHTRV108E[
7.50/10.00 KW Heater (208/240V 1PH) (4WCZ6036-0601) ................................................ BAYHTRV110E[
11.27/15.00 KW Heater (208/240V 1PH) (4WCZ6036-060A1) ............................................ BAYHTRV115E[
15.00/20.00 KW Heater (208/240V 1PH) (4WCZ6048-060A1) ............................................ BAYHTRV120E[
18.78/25.00 KW Heater (208/240V 1PH) (4WCZ6048-060A1) ............................................. BAYHTRV125E[
SUPPLEMENTARY HEATERS (3 PHASE)
3.76/5.00 KW Heater (208/240V 3PH) (4WCZ6036-060A3) ................................................. BAYHTRV305E[
6.00/8.00 KW Heater (208/240V 3PH( (4WCZ6036-060A3) ................................................. BAYHTRV308E[
7.50/10.00 KW Heater (208/240V 3PH) (4WCZ6036-060A3) ............................................... BAYHTRV310E[
11.27/15.00 KW Heater (208/240V 3PH) (4WCZ6036-060A3) ............................................. BAYHTRV315E[
15.00/20.00 KW Heater (208/240V 3PH) (4WCZ6048-060A3) ............................................. BAYHTRV320E[
18.78/25.00 KW Heater (208/240V 3PH) (4WCZ6048-060A3) ............................................. BAYHTRV325E[
5.00 KW Heater (460V 3PH) (4WCZ6036-060A4) ................................................................ BAYHTRV405E[
8.00 KW Heater (460V 3PH( (4WCZ6036-060A4) ................................................................ BAYHTRV408E[
10.00 KW Heater (460V 3PH) (4WCZ6036-060A4) .............................................................. BAYHTRV410E[
10.00 KW Heater (460V 3PH) (4WCZ6036-060A4) .............................................................. BAYHTRV415E[
10.00 KW Heater (460V 3PH) (4WCZ6048-060A4) .............................................................. BAYHTRV420E[
15.00 KW Heater (460V 3PH) (4WCZ6048-060A4) .............................................................. BAYHTRV425E[
Single Power Entry Kit 8 . ..................................................................................................... BAYSPEK060E[
Single Power Entry Kit 8 . ..................................................................................................... BAYSPEK061E[
Single Power Entry Kit 8 . ..................................................................................................... BAYSPEK062E[
Single Power Entry Kit 8 . ..................................................................................................... BAYSPEK063E[
Single Power Entry Kit 8 . ..................................................................................................... BAYSPEK064E[
Single Power Entry Kit 8 . ..................................................................................................... BAYSPEK065E[
NOTES: 1
2
3
4
5
6
7
8
9
0
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
Must use internal filter frame when economizer or fresh air kit is used.
Dry bulb control standard with economizer.
Ships knocked down.
Downflow only.
Low Ambient cooling requires crankcase heater (BAYCCHT----A).
It is the responsibility of the installing dealer to properly size the ductwork for each specific application.
BAYCOVR112,118A will not cover BAYSQRD002A applications.
See tables on pages 8 - 11 for matching kit with units and heaters.
BAYOSAC001B is not compatible with BAYACCDOR1A or BAYACCDOR2A.
BAYACCDOR1A requires BAYFLTR101B & BAYACCDOR2A requires BAYFLTR201B. They are not backward
compatible to BAYFLTR101/201A.
General Data
MODEL
RATED Volts/PH/Hz
Performance Cooling
BTUH (High)
Indoor Airflow (CFM)
Power Input (KW)
BTUH (Low)
Indoor Airflow (CFM)
Power Input (KW)
EER - HI / LOW / SEER
4WCZ6036A1000A
208-230/1/60
4WCZ6036A3000A
208-230/3/60
4WCZ6036A4000A
460/3/60
36000
1125
2.61
25200
825
1.8
12.2 / 13.3 / 16.4
70
36000
1125
2.61
25200
825
1.8
12.2 / 13.3 / 16.4
70
36000
1125
2.61
25200
825
1.8
12.2 / 13.3 / 16.4
70
34000 / 3.9
2.59
20800 / 2.62
2.371
23400 / 3.9
1.8
13300 / 2.2
1.78
9
208-230/3/60
19.1
30 / 30
2-STAGE SCROLL
208-230/3/60
11.2 / 58
SPINE-FIN
2 / 24
15.49
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
3020
1/6 / 830
208-230/1/60
0.9 / 1.65
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
208-230/1/60
4.3 / 4.3
NO
THROWAWAY
4.0
R410A / 7.8
HXWXL
47.86 / 44.5 / 52.03
468 / 372
34000 / 3.9
2.59
20800 / 2.62
2.371
23400 / 3.9
1.8
13300 / 2.2
1.78
9
460/3/60
10.4
15 / 15
SCROLL
460/3/60
4.5 / 29
Spine-Fin
2 / 24
15.49
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
3.54
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
23.4
DIRECT / 1
3020
1/6 / 830
460/1/60
0.5 / 0.84
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1/2 / VARIABLE
208-230/1/60
4.3 / 4.3
NO
THROWAWAY
4.0
R410A / 7.8
HXWXL
47.86 / 44.5 / 52.03
468 / 372
7 Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are
used size per manufacturer's recommendations with clean resistance of 0.05" W.C.
General Data
MODEL
RATED Volts/PH/Hz
Performance Cooling
BTUH (High)
Indoor Airflow (CFM)
Power Input (KW)
BTUH (Low)
Indoor Airflow (CFM)
Power Input (KW)
EER - HI / LOW / SEER
4WCZ6048A1000A
208-230/1/60
4WCZ6048A3000A
208-230/3/60
4WCZ6048A4000A
460/3/60
47500
1575
3.26
34500
1150
2.58
12.0 / 13.6 / 16.0
71
47500
1575
3.26
34500
1150
2.58
12.0 / 13.6 / 16.0
71
47500
1575
3.26
34500
1150
2.58
12.0 / 13.6 / 16.0
71
44500 / 4.0
3.26
27000 / 2.67
2.96
32400 / 4.0
2.37
18500 / 2.42
2.24
9.0
208-230/1/60
34.1
50 / 50
2-STAGE SCROLL
208-230/1/60
21.2 / 96.0
SPINE-FIN
2 / 24
23.57
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
4220
1/6 / 830
208-230/1/60
0.9 / 1.65
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
3/4 / VARIABLE
208-230/1/60
6.8 / 6.8
NO
THROWAWAY
5.3
R410A / 8.8
HXWXL
52.0 / 47.0 / 62.0
607 / 479
44500 / 4.0
3.26
27000 / 2.67
2.96
32400 / 4.0
2.37
18500 / 2.42
2.24
9.0
208-230/3/60
24.5
35 / 35
2-STAGE SCROLL
208-230/3/60
13.5 / 88.0
SPINE-FIN
2 / 24
23.57
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
4220
1/6 / 830
208-230/1/60
0.9 / 1.65
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
3/4 / VARIABLE
208-230/1/60
6.8 / 6.8
NO
THROWAWAY
5.3
R410A / 8.8
HXWXL
52.0 / 47.0 / 62.0
607 / 479
44500 / 4.0
3.26
27000 / 2.67
2.96
32400 / 4.0
2.37
18500 / 2.42
2.24
9.0
460/3/60
15.3
20 / 20
2-STAGE SCROLL
460/3/60
6.4 / 41.0
SPINE-FIN
2 / 24
23.57
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
4220
1/6 / 830
460/1/60
0.5 / 0.84
CENTRIFUGAL
10 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
3/4 / VARIABLE
208-230/1/60
6.8 / 6.8
NO
THROWAWAY
5.3
R410A / 8.8
HXWXL
52.0 / 47.0 / 62.0
607 / 479
Performance Heatingj
(High Temp.)BTUH / COP (High)
Power Input (KW)
(Low Temp.) BTUH / COP (High)
Power Input (KW)
(High Temp.)BTUH / COP (Low)
Power Input (KW)
(Low Temp.) BTUH / COP (Low)
Power Input (KW)
HSPF (BTU / Watt-Hr.)o
POWER CONN.V/Ph/Hz
Min. Brch. Cir. Ampacityl
Fuse Size Max. / Recmd. (amps)
COMPRESSOR
Volts/Ph/Hz
R.L. Amps L.R. Amps
OUTDOOR COIL TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
INDOOR COIL TYPE
Rows/F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Refrigerant Control
Drain Conn. Size (in.)
OUTDOOR FAN TYPE
Dia. (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.m
Motor HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
INDOOR FAN TYPE
Dia x Width (in.)
Drive/No. Speeds
CFM @ 0.0 in. w.g.n
Motor HP/R.P.M.
Volts/Ph/Hz
F.L. Amps/L.R. Amps
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft.)p
REFRIGERANT / Charge (lbs.)
DIMENSIONS
Crated (in.)
WEIGHT / Shipping / Net (lbs.)
General Data
MODEL
RATED Volts/PH/Hz
Performance Cooling
BTUH (High)
Indoor Airflow (CFM)
Power Input (KW)
BTUH (Low)
Indoor Airflow (CFM)
Power Input (KW)
EER - HI / LOW / SEER
4WCZ6060A1000A
208-230/1/60
4WCZ6060A3000A
208-230/3/60
4WCZ6060A4000A
460/3/60
56500
1900
4.18
40800
1350
3.23
11.5 / 12.5 / 15.2
73
56500
1900
4.18
40800
1350
3.23
11.5 / 12.5 / 15.2
73
56500
1900
4.18
40800
1350
3.23
11.5 / 12.5 / 15.2
73
55000 / 3.85
4.18
35000 / 2.58
3.97
38900 / 3.8
3.14
22800 / 2.2
3.04
8.6
208-230/3/60
30.3
45 / 45
2-STAGE SCROLL
208-230/3/60
17.6 / 123.0
SPINE-FIN
2 / 24
23.57
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
4720
1/4 / 830
208-230/1/60
1.4 / 3.37
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1 / VARIABLE
208-230/1/60
6.9 / 6.9
NO
THROWAWAY
5.3
R410A / 9.4
HXWXL
52.0 / 47.0 / 62.0
623 / 495
55000 / 3.85
4.18
35000 / 2.58
3.97
38900 / 3.8
3.14
22800 / 2.2
3.04
8.6
460/3/60
19.2
25 / 25
2-STAGE SCROLL
460/3/60
9.2 / 62.0
SPINE-FIN
2 / 24
23.57
3/8
EXPANSION VALVE
PLATE FIN
4 / 15
5.0
3/8
EXPANSION VALVE
3/4 FEMALE NPT
PROPELLER
28.2
DIRECT / 1
4720
1/4 / 830
460/1/60
0.7 / 1.68
CENTRIFUGAL
11 X 10
DIRECT / VARIABLE
SEE FAN PERFORMANCE TABLE
1 / VARIABLE
208-230/1/60
6.9 / 6.9
NO
THROWAWAY
5.3
R410A / 9.4
HXWXL
52.0 / 47.0 / 62.0
623 / 495
Performance Heatingj
(High Temp.)BTUH / COP (High)
55000 / 3.85
Power Input (KW)
4.18
(Low Temp.) BTUH / COP (High)
35000 / 2.58
Power Input (KW)
3.97
(High Temp.)BTUH / COP (Low)
38900 / 3.8
Power Input (KW)
3.14
(Low Temp.) BTUH / COP (Low)
22800 / 2.2
Power Input (KW)
3.04
HSPF (BTU / Watt-Hr.)o
8.6
POWER CONN.V/Ph/Hz
208-230/1/60
Min. Brch. Cir. Ampacityl
37.1
Fuse Size Max. / Recmd. (amps)
60 / 60
COMPRESSOR
2-STAGE SCROLL
Volts/Ph/Hz
208-230/1/60
R.L. Amps L.R. Amps
23.0 / 118.0
OUTDOOR COIL TYPE
SPINE-FIN
Rows/F.P.I.
2 / 24
Face Area (sq.ft.)
23.57
Tube Size (in.)
3/8
Refrigerant Control
EXPANSION VALVE
INDOOR COIL TYPE
PLATE FIN
Rows/F.P.I.
4 / 15
Face Area (sq.ft.)
5.0
Tube Size (in.)
3/8
Refrigerant Control
EXPANSION VALVE
Drain Conn. Size (in.)
3/4 FEMALE NPT
OUTDOOR FAN TYPE
PROPELLER
Dia. (in.)
28.2
Drive/No. Speeds
DIRECT / 1
CFM @ 0.0 in. w.g.m
4720
Motor HP/R.P.M.
1/4 / 830
Volts/Ph/Hz
208-230/1/60
F.L. Amps/L.R. Amps
1.4 / 3.37
INDOOR FAN TYPE
CENTRIFUGAL
Dia x Width (in.)
11 X 10
Drive/No. Speeds
DIRECT / VARIABLE
CFM @ 0.0 in. w.g.n
SEE FAN PERFORMANCE TABLE
Motor HP/R.P.M.
1 / VARIABLE
Volts/Ph/Hz
208-230/1/60
F.L. Amps/L.R. Amps
6.9 / 6.9
FILTER / FURNISHED
NO
Type Recommended
THROWAWAY
Recmd. Face Area (sq. ft.)p
5.3
REFRIGERANT / Charge (lbs.)
R410A / 9.4
DIMENSIONS
HXWXL
Crated (in.)
52.0 / 47.0 / 62.0
WEIGHT / Shipping / Net (lbs.)
623 / 495
1 Certified in accordance with the Unitary Air-Conditioner Equipment
certification program, which is based on ARI Standard 210/240.
2 Sound Power values are not adjusted for ARI 270-95 tonal corrections.
3 Calculated in accordance with currently prevailing Nat'l Electrical Code.
4 Standard Air Dry Coil Outdoor.
5 Standard Air Wet Coil Indoor.
6 Rated in accordance with D.O.E. test procedure.
7 Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are
used size per manufacturer's recommendations with clean resistance of 0.05" W.C.
Heater Data
Table 1. 4WCZ6036A to 4WCZ6060A Heater Data
UNIT MODEL
RATED
ELECTRIC
HEATER MODEL VOLTAGE
HEATER CAPACITY
PHASE
AMPS
KW
BTUH
KW/STAGE
NO. OF
STAGES
MCA
1
^W/TC*3018-060A1
^W/TCY4024-060A1
^WCZ6036-060A1
BAYHTRV105E
208/240
18/21
3.76/5.0
12800/17100
3.76/5.0
23/26
25/30
25/30
^W/TC*3018-060A1
^W/TCY4024-060A1
^WCZ6036-060A1
BAYHTRV108E
208/240
29/33
6.0/8.0
20500/27300
6.0/8.0
36/41
40/45
40/45
208/240
36/42
7.5/10.0
25600/34100
7.5/10.0
45/52
45/60
45/60
^W/TC*3024-060A1
^W/TCY4024-060A1 BAYHTRV110E
^WCZ6036-060A1
^W/TC*3030-060A1
^W/TCY4030-060A1 BAYHTRV115E#
^WCZ6036-060A1
^W/TC*3048-060A1
^W/TCY4042-060A1 BAYHTRV120E#
^WCZ6048-060A1
^W/TC*3060A1
^W/TCY4042-060A1 BAYHTRV125E#
^WCZ6048-060A1
^W/TC*3036-060A3
^W/TCY4036-060A3 BAYHTRV305E
^WCZ6036-060A3
208/240
54/63
11.27/15.0 38500/51200
7.5/10.0
3.76/5.0
68/78
70/80
70/80
208/240
72/83
15.0/20.0
51200/68300
7.5/10.0
7.5/10.0 90/104
90/110
90/110
208/240
125/150
125/150
208/240
10/12
3.76/5.0
12800/17100
3.76/5.0
13/15
15/15
15/15
^W/TC*3036-060A3
^W/TCY4036-060A3
^WCZ6036-060A3
208/240
17/19
6.0/8.0
20500/27300
6.0/8.0
21/24
25/25
25/25
208/240
21/24
7.5/10.0
25600/34100
7.5/10.0
26/30
30/30
30/30
208/240
31/36
11.27/15.0 38500/51200
7.5/10.0
3.76/5.0
39/45
40/45
40/45
208/240
42/48
15.0/20.0
51200/68300
7.5/10.0
7.5/10.0
52/60
60/60
60/60
208/240
52/60
18.78/25.0 64100/85300
11.26/15.0 7.5/10.0
65/75
70/80
70/80
BAYHTRV308E
^W/TC*3036-060A3
^W/TCY4036-060A3 BAYHTRV310E
^WCZ6036-060A3
^W/TC*3036-060A3
^W/TCY4036-060A3 BAYHTRV315E
^WCZ6036-060A3
^W/TC*3048-060A3
^W/TCY4048-060A3 BAYHTRV320E
^WCZ6048-060A3
^W/TC*3060A3
^W/TCY4048-060A3 BAYHTRV325E#
^WCZ6048-060A3
^W/TC*3036-060A4
^WCZ6036-060A4
BAYHTRV405E
480
5.0
17100
5.0
15
15
^W/TC*3036-060A4
^WCZ6036-060A4
BAYHTRV408E
480
10
8.0
27300
8.0
13
15
15
BAYHTRV410E
480
12
10.0
34100
10.0
15
15
15
BAYHTRV415E
480
18
15.0
51200
10.0
5.0
23
25
25
BAYHTRV420E
480
24
20.0
68300
10.0
10.0
30
30
30
BAYHTRV425E
480
30
25.0
85300
15.0
10.0
38
40
40
^W/TC*3036-060A4
^WCZ6036-060A4
^W/TC*3036-060A4
^WCZ6036-060A4
^W/TC*3048-060A4
^WCZ6048-060A4
^W/TC*3060A4
^WCZ6048-060A4
NOTES:
1. Any power supply and circuits must be wired and protected in accordance with local electrical codes.
2. The MCA values listed are for electric heater only.
3. Field wire must be rated at least 75C
4. The HACR circuit breaker is for U.S.A. installations only.
5. For Canada installation reference only.
# Heater uses fuses.
8
10
11
85
95
105
115
OD
Amb
75
85
90
95
ID
WB
TOTAL
CAP
25.6
25.1
24.9
24.6
3.7
3.9
AIR FLOW
CAPACITY
TOTAL POWER
59.0
35.2
29.2
32.8
35.2
35.2
2.6
RATE, CFM
MULTIPLIER
MULTIPLIER
63.0
36.9
23.9
27.5
31.0
33.4
2.7
LOW
1050
0.98
0.99
67.0
39.5
18.8
22.4
26.0
28.4
2.7
HIGH
1350
1.02
1.01
71.0
42.8
13.9
17.4
21.0
23.4
2.7
59.0
32.5
28.0
31.5
32.5
32.5
2.9
63.0
34.1
22.7
26.3
29.9
32.3
2.9
CFM
SEER
EER
67.0
36.4
17.6
21.2
24.8
27.2
2.9
1130
36000
16.4
12.2
71.0
39.5
12.7
16.3
19.9
22.3
3.0
59.0
29.7
26.8
29.5
29.7
29.7
3.1
63.0
31.2
21.5
25.1
28.7
31.1
3.1
67.0
33.3
16.5
20.0
23.6
26.0
3.2
71.0
36.2
11.6
15.2
18.8
21.2
3.2
59.0
27.0
25.6
27.0
27.0
27.0
3.3
63.0
28.3
20.4
24.0
27.6
28.3
3.4
67.0
30.2
15.3
18.9
22.5
24.9
3.4
71.0
32.8
10.4
14.0
17.6
20.0
3.4
ID
WB
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
72
75
78
80
TOTAL
KW
LOW STAGE: 4WCZ6036A1/3/4 AT 1200 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE)
SENS CAP AT ENTERING DB TEMP
Total
Total
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
72
75
78
80
Cap
Kw
26.9
22.6
25.5
26.9
26.9
1.24
AIR FLOW
CAPACITY
TOTAL POWER
28.2
18.5
21.3
24.1
25.9
1.25
30.2
14.6
17.4
20.2
22
1.26
RATE, CFM
MULTIPLIER
MULTIPLIER
32.7
10.7
13.6
16.3
18.2
1.27
LOW
700
0.98
0.99
25
21.8
24.4
25
25
1.68
HIGH
900
1.02
1.01
26.2
17.7
20.5
23.3
25.1
1.69
A.H.R.I RATING FOR COOLING
28
13.7
16.5
19.3
21.2
1.71
CAPACITY (A) TEST
30.4
9.9
12.8
15.5
17.4
1.72
CFM
SEER
EER
25200
24
21.4
23.6
24
24
1.89
1130
16.4
12.2
25.2
17.3
20
22.9
24.7
1.91
A.H.R.I. Standard Capacity Rating Conditions
26.9
13.3
16.1
18.9
20.8
1.93
A.H.R.I. Standard 210/240 Rating Conditions - (A) Cooling 80F DB, 67F WB air
29.2
9.5
12.4
15.1
17
1.95
entering indoor coil, 95F DB air entering outdoor coil. (B) High Temperature
Heating 47F DB, 43F WB air entering outdoor coil, 70F DB air entering indoor
23.1
21
23
23.1
23.1
2.11
coil. (C) Low Temperature Heating 17F DB, 15F WB air entering outdoor coil,
24.2
16.9
19.6
22.5
24.2
2.13
70F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same
as for cooling.
25.8
12.9
15.8
18.5
20.4
2.15
28
9.1
11.9
14.7
16.6
2.17
HIGH STAGE: 4WCZ6048A1/3/4 AT1600 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE)
OD
Amb
85
95
105
115
ID
WB
TOTAL
CAP
25.6
25.1
24.9
24.6
3.7
3.9
AIR FLOW
CAPACITY
TOTAL POWER
59.0
45.2
38.7
43.6
45.2
45.2
3.6
RATE, CFM
MULTIPLIER
MULTIPLIER
63.0
47.4
31.4
36.3
41.2
44.5
3.6
LOW
1400
0.98
0.99
67.0
50.7
24.4
29.4
34.3
37.5
3.6
HIGH
1800
1.02
1.01
71.0
55.0
17.6
22.5
27.5
30.8
3.7
59.0
42.5
37.5
41.7
42.5
42.5
3.9
63.0
44.6
30.2
35.2
40.1
43.4
3.9
CFM
SEER
EER
67.0
47.6
23.2
28.1
33.1
36.4
4.0
1580
47500
16
12
71.0
51.7
16.5
21.5
26.4
29.6
4.0
59.0
39.8
36.3
39.7
39.8
39.8
4.2
63.0
41.7
29.0
34.0
38.9
41.7
4.2
67.0
44.5
22.1
27.0
31.9
35.2
4.3
71.0
48.3
15.3
20.2
25.2
28.5
4.3
59.0
37.0
35.1
37.0
37.0
37.0
4.5
63.0
38.8
27.9
32.8
37.7
38.8
4.6
67.0
41.5
21.0
25.9
30.8
34.1
4.6
71.0
45.0
14.2
19.1
24.1
27.4
4.7
72
75
78
80
TOTAL
KW
12
85
90
95
ID
WB
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
LOW STAGE: 4WCZ6048A1/3/4 AT 1600 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE)
SENS CAP AT ENTERING DB TEMP
Total
Total
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
72
75
78
80
Cap
Kw
36.6
31.4
35.3
36.6
36.6
1.74
AIR FLOW
CAPACITY
TOTAL POWER
38.4
25.5
29.5
33.4
36.1
1.76
41
20
23.9
27.8
30.5
1.78
RATE, CFM
MULTIPLIER
MULTIPLIER
44.5
14.6
18.5
22.5
25.1
1.79
LOW
1050
0.98
0.99
34.2
30.3
33.5
34.2
34.2
2.31
HIGH
1350
1.02
1.01
35.8
24.5
28.4
32.4
35
2.33
A.H.R.I RATING FOR COOLING
38.3
18.9
22.9
26.8
29.5
2.35
CAPACITY (A) TEST
41.5
13.5
17.5
21.4
24.1
2.37
CFM
SEER
EER
35000
33
29.8
32.7
33
33
2.59
1580
16
12
34.6
24
27.9
31.9
34.5
2.61
A.H.R.I. Standard Capacity Rating Conditions
36.9
18.4
22.4
26.3
28.9
2.64
A.H.R.I. Standard 210/240 Rating Conditions - (A) Cooling 80F DB, 67F WB air
40.1
13.1
17
21
23.6
2.66
entering indoor coil, 95F DB air entering outdoor coil. (B) High Temperature
Heating 47F DB, 43F WB air entering outdoor coil, 70F DB air entering indoor
31.8
29.2
31.8
31.8
31.8
2.87
coil. (C) Low Temperature Heating 17F DB, 15F WB air entering outdoor coil,
33.3
23.5
27.4
31.3
33.3
2.9
70F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same
as for cooling.
35.6
17.9
21.9
25.8
28.4
2.93
38.6
12.6
16.5
20.4
23.1
2.96
HIGH STAGE: 4WCZ6060A1/3/4 AT 2000 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE)
OD
Amb
85
95
105
115
OD
Amb
75
85
90
95
ID
WB
TOTAL
CAP
25.6
25.1
24.9
24.6
3.7
3.9
AIR FLOW
CAPACITY
TOTAL POWER
59.0
54.3
46.5
52.4
54.3
54.3
4.4
RATE, CFM
MULTIPLIER
MULTIPLIER
63.0
57.0
37.6
43.6
49.7
53.7
4.4
LOW
1750
0.98
0.99
67.0
60.9
29.1
35.1
41.1
45.1
4.5
HIGH
2250
1.02
1.01
71.0
66.1
20.8
26.9
32.9
36.9
4.5
59.0
50.9
45.0
50.0
50.9
50.9
4.8
63.0
53.4
36.2
42.2
48.2
52.2
4.8
CFM
SEER
EER
67.0
57.0
27.6
33.6
39.7
43.7
4.9
1900
56500
15.2
11.5
71.0
61.9
19.4
25.4
31.4
35.5
4.9
59.0
47.5
43.5
47.5
47.5
47.5
5.2
63.0
49.8
34.7
40.7
46.7
49.8
5.3
67.0
53.2
26.2
32.2
38.3
42.3
5.3
71.0
57.7
18.0
24.0
30.0
34.0
5.4
59.0
44.0
42.0
44.0
44.0
44.0
5.6
63.0
46.2
33.3
39.3
45.3
46.2
5.7
67.0
49.3
24.8
30.8
36.8
40.8
5.7
71.0
53.5
16.6
22.6
28.6
32.6
5.8
ID
WB
59
63
67
71
59
63
67
71
59
63
67
71
59
63
67
71
72
75
78
80
TOTAL
KW
LOW STAGE: 4WCZ6060A1/3/4 AT 2000 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE)
SENS CAP AT ENTERING DB TEMP
Total
Total
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
72
75
78
80
Cap
Kw
42.3
37.6
41.5
42.3
42.3
2.06
AIR FLOW
CAPACITY
TOTAL POWER
44.4
30.4
35.3
40.2
43.4
2.08
47.4
23.5
28.4
33.3
36.5
2.1
RATE, CFM
MULTIPLIER
MULTIPLIER
51.5
16.9
21.8
26.6
29.9
2.12
LOW
1225
0.98
0.99
39.9
36.5
39.8
39.9
39.9
2.83
HIGH
1575
1.02
1.01
41.9
29.4
34.3
39.2
41.9
2.86
A.H.R.I RATING FOR COOLING
44.7
22.5
27.4
32.3
35.5
2.88
CAPACITY (A) TEST
48.5
15.8
20.8
25.6
28.9
2.91
CFM
SEER
EER
40500
38.7
36
38.7
38.7
38.7
3.22
1900
15.2
11.5
40.6
28.9
33.8
38.6
40.6
3.25
A.H.R.I. Standard Capacity Rating Conditions
43.4
22
26.9
31.8
35.1
3.28
A.H.R.I. Standard 210/240 Rating Conditions - (A) Cooling 80F DB, 67F WB air
47.1
15.4
20.2
25.2
28.4
3.31
entering indoor coil, 95F DB air entering outdoor coil. (B) High Temperature
Heating 47F DB, 43F WB air entering outdoor coil, 70F DB air entering indoor
37.5
35.5
37.5
37.5
37.5
3.6
coil. (C) Low Temperature Heating 17F DB, 15F WB air entering outdoor coil,
39.4
28.4
33.3
38.2
39.4
3.64
70F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same
as for cooling.
42
21.5
26.4
31.3
34.6
3.67
45.6
14.9
19.8
24.6
27.9
3.71
13
70
75
80
60
70
75
80
14.5
16.8
19.1
21.3
22.7
14.3
16.5
18.7
20.9
22.3
14.1
16.3
18.5
20.7
22.1
14
16.2
18.3
20.5
21.9
2.13
2.16
2.2
2.24
2.26
2.23
2.27
2.31
2.35
2.37
2.29
2.33
2.37
2.41
2.43
2.34
2.38
2.42
2.46
2.49
24.2
25.6
27.9
31.3
34.8
37.1
39.3
41.6
43.8
46.1
23.7
25.1
27.3
30.8
34.2
36.4
38.6
40.8
43
45.2
23.5
24.9
27.1
30.5
33.8
36
38.2
40.4
42.6
44.8
23.3
24.7
26.8
30.2
33.5
35.7
37.9
40
42.2
44.4
2.28
2.3
2.34
2.4
2.45
2.49
2.53
2.56
2.6
2.63
2.4
2.42
2.46
2.52
2.58
2.62
2.66
2.7
2.73
2.77
2.46
2.48
2.52
2.58
2.64
2.68
2.72
2.76
2.8
2.84
2.51
2.54
2.58
2.64
2.71
2.75
2.79
2.83
2.87
2.91
AIR FLOW
CAPACITY
TOTAL POWER
RATE, CFM
MULTIPLIER
MULTIPLIER
LOW
1050
0.99
0.98
HIGH
1350
1.01
1.03
CFM
CAPACITY
47
COP
47
CAPACITY
17
COP
17
HSPF
1130
34000
3.9
20800
2.62
LOW STAGE: 4WCZ6036A1/3/4 AT 1200 NOM CFM (HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE)
OD
Amb
2
7
12
17
22
27
32
37
42
47
52
57
62
67
72
60
1.5
3.2
4.9
6.6
8.2
9.9
11.6
13.3
14.5
15.6
16.7
18.4
20.9
23.4
25.1
9.7
11.4
13.1
14.2
15.3
16.4
18.1
20.5
23
24.6
9.7
11.3
12.9
14
15.2
16.3
17.9
20.3
22.8
24.4
80
1.4
3.1
4.7
6.3
7.9
9.6
11.2
12.8
13.9
15
16.1
17.7
20.1
22.5
24.2
1.75
1.76
1.76
1.76
1.76
1.76
1.77
1.79
1.81
1.82
1.79
1.8
1.81
1.81
1.8
1.8
1.81
1.83
1.85
1.86
1.84
1.84
1.85
1.85
1.85
1.85
1.85
1.88
1.9
1.91
CAPACITY
TOTAL POWER
RATE, CFM
MULTIPLIER
MULTIPLIER
LOW
700
0.99
0.98
HIGH
900
1.01
1.03
CFM
CAPACITY
47
COP
47
CAPACITY
17
COP
17
HSPF
1130
34000
3.9
20800
2.62
HIGH STAGE: 4WCZ6048A1/3/4 AT 1600 NOM CFM (HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE)
OD
Amb
2
7
12
17
22
27
32
37
42
47
52
57
62
67
72
70
75
80
60
70
75
80
18.6
21.6
24.6
27.5
29.4
18.3
21.2
24.1
27
28.9
18.1
21
23.9
26.8
28.6
17.9
20.8
23.6
26.5
28.3
2.67
2.72
2.77
2.82
2.85
2.8
2.85
2.91
2.96
2.99
2.87
2.92
2.98
3.03
3.06
2.94
2.99
3.04
3.1
3.13
31.4
33.3
36.2
40.8
45.4
48.3
51.3
54.3
57.3
60.2
30.8
32.6
35.6
40
44.5
47.4
50.4
53.3
56.2
59.1
30.5
32.3
35.2
39.7
44.1
47
49.9
52.8
55.7
58.5
30.2
32
34.9
39.3
43.7
46.5
49.4
52.3
55.1
58
2.88
2.91
2.96
3.03
3.11
3.16
3.2
3.25
3.3
3.35
3.02
3.06
3.11
3.19
3.27
3.32
3.37
3.42
3.47
3.52
3.1
3.13
3.18
3.26
3.35
3.4
3.45
3.5
3.56
3.61
3.17
3.2
3.26
3.34
3.43
3.48
3.53
3.59
3.64
3.7
14
AIR FLOW
CAPACITY
TOTAL POWER
RATE, CFM
MULTIPLIER
MULTIPLIER
LOW
1400
0.99
0.98
HIGH
1800
1.01
1.03
CFM
CAPACITY
47
COP
47
CAPACITY
17
COP
17
HSPF
1580
44500
27000
2.68
60
2.2
4.5
6.8
9.2
11.5
13.8
16.1
18.4
20
21.6
23.2
25.5
28.9
32.4
34.7
13.5
15.8
18.1
19.6
21.2
22.7
25
28.4
31.8
34
13.4
15.7
17.9
19.5
21
22.5
24.8
28.1
31.5
33.7
80
2.1
4.3
6.6
8.8
11
13.3
15.5
17.7
19.3
20.8
22.3
24.5
27.8
31.1
33.4
2.06
2.08
2.1
2.11
2.11
2.12
2.14
2.18
2.21
2.23
2.16
2.19
2.21
2.22
2.22
2.23
2.25
2.29
2.33
2.35
2.22
2.24
2.26
2.27
2.28
2.29
2.31
2.35
2.39
2.41
2.27
2.29
2.32
2.33
2.34
2.34
2.37
2.41
2.45
2.47
CAPACITY
TOTAL POWER
RATE, CFM
MULTIPLIER
MULTIPLIER
LOW
1050
0.99
0.98
HIGH
1350
1.01
1.03
CFM
CAPACITY
47
COP
47
CAPACITY
17
COP
17
HSPF
1580
44500
27000
2.68
HIGH STAGE: 4WCZ6060A1/3/4 AT 2000 NOM CFM (HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE)
OD
Amb
2
7
12
17
22
27
32
37
42
47
52
57
62
67
72
70
75
80
60
70
75
80
25.6
29
32.4
35.8
37.9
25.1
28.5
31.8
35.1
37.2
24.9
28.2
31.5
34.8
36.8
24.6
27.9
31.2
34.5
36.5
3.73
3.76
3.79
3.82
3.83
3.91
3.94
3.97
4.01
4.02
4
4.03
4.07
4.1
4.11
4.09
4.12
4.16
4.19
4.2
40
42
45.5
50.9
56.3
59.7
63.1
66.5
69.9
73.3
39.2
41.3
44.6
49.9
55.2
58.6
61.9
65.3
68.6
72
38.8
40.9
44.2
49.4
54.7
58
61.3
64.7
68
71.3
38.5
40.5
43.8
49
54.2
57.5
60.7
64
67.3
70.6
3.84
3.85
3.88
3.95
4.01
4.04
4.07
4.11
4.14
4.17
4.03
4.04
4.07
4.14
4.21
4.24
4.28
4.31
4.34
4.38
4.12
4.13
4.17
4.24
4.31
4.34
4.38
4.41
4.45
4.48
4.21
4.22
4.26
4.33
4.41
4.44
4.48
4.51
4.55
4.59
AIR FLOW
CAPACITY
TOTAL POWER
RATE, CFM
MULTIPLIER
MULTIPLIER
LOW
1750
0.99
0.98
HIGH
2250
1.01
1.03
CFM
CAPACITY
47
COP
47
CAPACITY
17
COP
17
HSPF
1900
55000
3.86
35000
2.58
8.6
LOW STAGE: 4WCZ6060A1/3/4 AT 2000 NOM CFM (HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE)
OD
Amb
2
7
12
17
22
27
32
37
42
47
52
57
62
67
72
60
4.2
6.9
9.5
12.1
14.7
17.4
20
22.6
24.4
26.1
27.8
30.5
34.4
38.4
41
16.9
19.4
22
23.7
25.4
27.1
29.6
33.5
37.3
39.9
16.7
19.3
21.8
23.5
25.1
26.8
29.3
33.2
37
39.5
2.64
2.68
2.72
2.74
2.76
2.78
2.82
2.88
2.94
2.98
2.71
2.74
2.78
2.8
2.83
2.85
2.89
2.95
3.02
3.06
2.77
2.81
2.85
2.87
2.89
2.92
2.96
3.02
3.09
3.13
15
CAPACITY
TOTAL POWER
RATE, CFM
MULTIPLIER
MULTIPLIER
LOW
1225
0.99
0.98
HIGH
1575
1.01
1.03
CFM
CAPACITY
47
COP
47
CAPACITY
17
COP
17
HSPF
1900
55000
3.86
35000
2.58
8.6
Down Flow
Low
350 CFM/Ton Setting
High
Low
400 CFM/Ton Setting
High
Low
450 CFM/Ton Setting
High
0
-
1
-
0
-
1
-
0.0
-
0.1
954
1363
1121
1601
1223
1747
0.2
973
1390
1106
1580
1254
1792
0.8
944
1349
1097
1567
1258
1797
0.9
-
1.0
-
0.0
-
0.1
948
1354
1102
1574
1295
1851
0.2
977
1396
1106
1580
1277
1824
0.8
962
1375
1118
1597
1273
1819
0.9
-
1.0
-
Low
High
Low
High
Down Flow
350 CFM/Ton Setting
400 CFM/Ton Setting
0.2
1238
1768
1427
2038
0.8
1230
1757
1410
2015
0.9
1.0
0.1
1163
1662
1443
2062
0.0
-
0.1
1259
1799
1410
2015
0.2
1219
1742
1393
1990
0.8
1185
1692
1344
1920
0.9
-
1.0
-
0.0
Low
High
Low
High
16
SELECTION
NOMINAL AIRFLOW
7-OFF
8-OFF
LOW
1050 CFM
7-ON
8-OFF
HIGH
1200 CFM
7-OFF
8-ON
HIGH
1200 CFM
7-ON
8-ON
HIGH
1200 CFM
SELECTION
NOMINAL AIRFLOW
7-OFF
8-OFF
LOW
1400 CFM
7-ON
8-OFF
HIGH
1600 CFM
7-OFF
8-ON
HIGH
1600 CFM
7-ON
8-ON
HIGH
1600 CFM
DELAY
NONE
45 SEC
90 SEC
**
NOMINAL
AIRFLOW
100%
100%
50%
50-100%
100%
Only if required
SECOND
STAGE
NOMINAL AIRFLOW
7-OFF
8-OFF
LOW
1400 CFM
7-ON
8-OFF
HIGH
1600 CFM
7-OFF
8-ON
HIGH
1600 CFM
7-ON
8-ON
HIGH
1600 CFM
SWITCH SETTINGS
80%
50%
50%
70%
Only if required
56%
FIRST
STAGE
35%
Dehumidify
Fast Coil Cooling
OFF
1
minute
Enhanced
Comfort
Enhanced
Efficiency
7.5
minutes
3
minutes
(Fan Only)
COMPRESSOR OPERATION ON
17
35%
OFF
OFF
Typical Wiring
18
Typical Wiring
19
Optional Equipment
BAYCURB050A FULL PERIMETER ROOF MOUNTING CURB FOR 4WCZ6036A
17 7/8
46 3/8
3
3 5/8
19 1/2
2 3/16
19 1/2
15
38 7/8
14
1 1/2
43 3/8
35 7/8
20
Optional Equipment
BAYCURB051A Full Perimeter Roof Mounting Curb for 4WCZ6048-060A
15 7/8
56 1/8
1 1/2
10 7/8
19 1/2
20
4 3/4
19 1/2
41 7/8
14
38 7/8
53 1/8
21
Optional Equipment
BAYFLTR101, 201B, 1" - 2" Filter Rack
(Mounts in Filter/Coil Section)
Filter
The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings
are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not
responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such
unauthorized use.
22
Optional Equipment
BAYECON103,104A Down Discharge Economizer and Rain Hood
(Mounts Over Horizontal Return Air Opening)
HVAC Unit
A
Economizer
Models
BAYECON103A
4WCZ6036A
4DCZ6036A
4YCZ6036A
20 1/8"
BAYECON104A
4WCZ6048-060A
4DCZ6048-060A
4YCZ6048-060A
24 3/8"
Economizer
rain hood
Outside air
dampers
Required filter
kit, order
separately
Return air
dampers
Mist
eliminator
Relief
damper
Roofcurb
Return
Duct
Economizer
B
D
Gaskets (2)
Duct
Rain Hood
Economizer
BAYECON203AA
22"
20"
16 7/8"
15 11/16
11 11/16
15
BAYECON204AA
26"
22 21/32"
19"
17 11/16
14 11/16
21-3/8
23
Optional Equipment
BAYOSAH001,002A, 25% Outside Air Damper
(Replaces Filter/Coil Access Panel)
FULLY
OPEN
2/3
1/3
FULLY
CLOSED
Manual Fresh
Air Model
Unit Application
Models
BAYOSAH001
2/4YC,WC3018-036
4TC*3018-036
4W/T/Y/DCY4024-036
4W/Y/DCZ6036
22 7/16"
20 11/16"
12 3/8"
9 3/16"
BAYOSAH002
2/4YC,WC3042-060
4TC*3042-060
4W/T/Y/DCY4042-060
4W/Y/DCZ6048-060
25 3/16"
20 11/16"
12 3/8"
9 3/16"
Unit Application
Models
2/4YC,WC3018-036
4TC3018-036
4W/T/Y/DCY4024-036
4W/Y/DCZ6036
2/4YC,WC3042-060
4TC3042-060
BAYDMPR102A
4W/T/Y/DCY4042-060
4W/Y/DCZ6048-060
BAYDMPR101A
D
A
15 13/16"
11 13/16"
10 1/4"
11 1/2"
12 1/4"
18 3/16"
15 1/8"
10 1/4"
11 1/2"
12 1/4"
24
Figure 1. WCZ6036A (1 of 3)
25
Figure 2. WCZ6036A (2 of 3)
26
Figure 3. WCZ6036A (3 of 3)
27
Mechanical Specifications
General
Condenser Coil
Unit Casing
All components shall be mounted in a
weather-resistant steel cabinet with an
enamel finish. Access panels shall be provided for unit controls and indoor coil and
fans. Indoor air section compartment shall
be completely insulated with fireproof, permanent, odorless glass fiber material.
Knockouts shall be provided for utility and
control connections. Drain connections
shall be provided to accommodate indoor
water runoff.
Compressor
The compressor shall be hermetically
sealed, high efficiency Climatuff two-stage
compressors. Internal overcurrent and over
temperature protection, internal pressure
relief shall be standard.
Refrigeration System
All units shall have TXV in cooling and TXV
in heating. Service pressure tap ports, and
a refrigerant line filter dryer shall be standard.
Indoor Coil
Coils shall be internally finned or smooth
bore 3/8" copper tubes mechanically bonded to configured aluminum plate fin as
standard. Evaporator coil leak and pressure tested to 200 psig; condenser coil
tested to 450 psig.
Trane
6200 Troup Highway
Tyler, TX 75707-9010
Single Source Power Entry This accessory when used with electric heat accessory
shall allow single source power connection
to unit and heater combination. Single
source power entry kits shall have specific
matching heater(s). Kit shall include high
voltage terminal blocks, fuse blocks and
fuses, cut-to-length interconnecting wiring,
and junction box (if required) to provide
power sources with fuse protection as required for both the unit and accessory
heater. Kit components shall install within
the unit cabinet in the heater access section. Single source branch power circuit
shall be protected and wired in accordance
with local codes.
Fully Modulating Economizer This accessory shall be field installed and be
composed of the following items: 0-100%
fresh air damper, damper drive motor, fixed
dry bulb enthalpy control, and low voltage
wiring plug for electrical connections. Solid
state enthalpy or differential enthalpy control is optional. Economizer operations shall
be controlled by the preset position of the
enthalpy control. A barometic relief damper
shall be standard with the economizer and
provide a pressure operated damper that
shall be gravity closing and prohibit entrance of outside air on equipment off
cycle. Economizer requires BAYRLAY004A
relay kit to interface the economizer to the
heat pump.
Manual Outside Air Dampers Rain
hood and screen shall be field installed.
Suitable for up to 25% outside air.
Start Kit Extra compressor starting capacity for single phase equipment.
Control Options
Standard Indoor Thermostats Two
stage heating/cooling or one stage heating/
cooling thermostats shall be available in either manual or automatic changeover.
Programmable Electronic Night Setback
Thermostat Programmable electronic
thermostat shall provide heating setback
and cooling setup with 7-day, programming
capability. 1H/1C or 2H/2C models available.
The manufacturer has a policy of continuous product and product data improvement and it reserves the right to
change design and specifications without notice.
31