Anda di halaman 1dari 17

2 Way Slip-In Cartridge Valves

Series CE, CP, C

Catalogue HY11-3500/UK

Characteristics
2 way slip-in cartridge valves are hydraulically controlled
seat valves that are designed for compact block installation. Slip-in cartridge, cover, and pilot system are valve
elements that permit single and combined functions.
Series CE offers poppet and sleeve combinations for
directional functions. Series CP offers a cartridge for
pressure functions and has to be combined with corresponding covers.
Features
Installation cavity and mounting pattern according to
ISO 7368
5 poppet shapes
5 poppet springs
Optional seal between ports B and C
Cover with adjustable stroke limitation
Cover with mounting pattern for pilot valve assembly
Combinations for complex functions
Normally open cartridge (CE*F04)

CE

C*B

C*A

C*C

Pilot control for directional functions


C*C
C016C to C040C

P A

Pilot control valves


for C*C and C*W
have to be ordered
separately

X Z1
Cover C

M
M
1

Z1 C Z2

C*A

3
Y

Z1 C Z2

C*B

Z1 C Z2

X Z2

C*W

C*V

4
Z2 Y

C050C to C100C
P
A
B
T

Z1 C Z2

2
C

4
Z1 Y

C*C

a see ordering code

Cartridge
valve CE

for details

CE*F04

CE*01

CE*04

CE*07

CE*08

CE-C UK.INDD CM 28.08.13

8-4

Parker Hannifin Corporation


Hydraulics Group

2 Way Slip-In Cartridge Valves


Series CE, CP, C

Catalogue HY11-3500/UK

Characteristics
Cartridge valve for directional function

CE*F04

1:1
AA = AC

1 : 1.67
AA = 0.6 AC
AB = 0.4 AC

1 : 1.04
AA = 0.96 AC

1 : 1.67
AA = 0.6 AC
AB = 0.4 AC
dampening poppet

1 : 1.67
AA = 0.6 AC
AB = 0.4 AC
normally open

Cartridge valve for pressure function

1 : 1.04
AA = 0.96 AC

Characteristic curves see complete valves pressure


function.

Pilot control for pressure function


Pilot control valves
for C*C and C*G
have to be ordered
separately
NG16, 25, 32

NG16, 25, 32
P
A
B T

P A

NG40

NG50, 63
A
B

2
2
X

1
Z1

C
C*F

Z2

3
X

1
Z1

Z2

X Z1

1
C

C*G

C*C

Z2 Y

X Z2

4
Z1 Y

C*C

Cartridge
valve CP

CP*07
CE-C UK.INDD CM 28.08.13

8-5

Parker Hannifin Corporation


Hydraulics Group

2 Way Slip-In Cartridge Valves


Series CE, CP, C

Catalogue HY11-3500/UK

Ordering Code

CE
Cartridge

Code
016
025
032
040
050
063
080
100

Nominal
size

Design

Poppet
area ratio

Spring

Orifice

(not required
for ordering)

Size
NG16
NG25
NG32
NG40
NG50
NG63
NG80
NG100

Code
N
V

08

Code

Size

Poppet

99

all

all

00
00
00

Code Normal position


Description
C
Closed
No poppet sealing
Closed
With poppet sealing
S 1)
Open
No poppet sealing
F 2)
Code
01
04
07 3)

Design
series

Seal

NG16-NG50 01, 04
NG16-NG50 07, 08
NG63-NG100
all
Code
L
N
S
T
U

Poppet area ratio


AA = AC
AA = 0.6AC, AB = 0.4AC
AA = 0.96AC
AA = 0.6AC, AB = 0.4AC
with dampening

Seal
NBR
FPM
Orifice 4)
without orifice,
open
closed bottom
plug
plug

Spring
Opening pressure
Opening pressure
Opening pressure
Opening pressure
Opening pressure

0.1 bar
0.5 bar
1.6 bar
2.5 bar
4.0 bar

1)

Only for spring S, T and U. Not for poppet code 01 (NG16 to NG63).
Only with spring code L, only with closed bottom.
3) Not for NG80 and NG100.
4) Orifice size in 1/10 mm, eg. 1.2 mm orifice - code 12. Thread size 1/16 NPTF.
2)

CP
Cartridge

Code
016
025
032
040
050
063

07
Nominal
size

Design

Poppet
area ratio
AA = 0.96AC

Size
NG16
NG25
NG32
NG40
NG50
NG63

1)

Orifice

Seal

Design
series
(not required
for ordering)

Code
N
V
Code
00
09
11
12
13
14
15

Code Normal position


Description
C
Closed
No poppet sealing
S
Closed
With poppet sealing
Code
S
T
U

Spring

Spring
Opening pressure 1.6 bar
Opening pressure 2.5 bar
Opening pressure 4.0 bar

Seal
NBR
FPM

Orifice 1)
Plug
0.9 mm for NG16
1.1 mm for NG25
1.2 mm for NG32
1.3 mm for NG40
1.4 mm for NG50
1.5 mm for NG63

For spare parts see "Accessories" in this chapter.


For orifice recommendations see "Combination
Examples" in this chapter.

Recommended diameter.

CE-C UK.INDD CM 28.08.13

8-6

Parker Hannifin Corporation


Hydraulics Group

Catalogue HY11-3500/UK

Technical Data / Performance Curves

2 Way Slip-In Cartridge Valves


Series CE, CP

Technical data
General
Design type
Actuation
Mounting position
Ambient temperature
MTTFD value
Nominal size
Weight
Hydraulic
Fluid
Viscosity
Fluid temperature
Max. contamination
Operating pressure

Nominal flow at p 5 bar


Pilot volume requirement

cartridge

recommended
max. permitted

without pilot valve


port A, B, X, Z1, Z2
port Y
poppet 01, 04, 07
poppet 08
at poppet 01
at poppet 04
at poppet 07
at poppet 08

Opening pressure

flow direction A B

Opening pressure

flow direction B A

2 way slip-in cartridge valves according to ISO 7368


hydraulic
unrestricted
[C] -20....+60
[years] 150
NG16
NG25
NG32
NG40
NG50
NG63
[kg]
0.3
0.6
1.1
1.7
3.7
7.1

NG80
12.8

Hydraulic fluid according to DIN 51524...51525


[mm2/s] 30...80
[mm2/s] 20...380
[C] -20...+60
ISO 4406 1999; 18/16/13
[bar] 420
[bar] 350, 420 (depending on pmax of pilot valves)
[bar] According to pilot system, max. 350 (depending on pmax of pilot valves)
[l/min]
250
450
900
1350
1800
3600
5250
[l/min]
230
400
800
1250
1625
3400
5000
[cm3]
2.0
6.5
10.2
17.4
34.5
77.4
190.1
2.0
6.5
12.2
20.3
39.4
94.6
190.1
2.0
6.5
10.2
17.4
34.5
77.4

2.0
7.4
15.3
23.2
49.2
111.8
217.3
Poppet 01 / 07
spring: L = 0.1 N = 0.5 S = 1.6 T = 2.5
[bar]
Poppet 04 / 08
spring: L = 0.2 N = 0.9 S = 2.7 T = 4
Poppet 01 / 07
not possible
[bar]
Poppet 04 / 08
spring: L = 0.3 N = 1.3 S = 4.0 T = 6.3

NG100
27

8000
7500
342.6
363.4

415.3
U = 4.0
U = 6.6
U = 10.0

Performance curves (without spring and poppet seal, C-chamber unloaded)


Poppet 01, 04, 07
Poppet 08

Poppet 01, 04, 07

Poppet 08

All characteristic curves measured with HLP46 at 50 C.


CE-C UK.INDD CM 28.08.13

8-7

Parker Hannifin Corporation


Hydraulics Group

2 Way Slip-In Cartridge Valves


Series C*A, Cover w/o Auxiliary Functions

Catalogue HY11-3500/UK

Ordering Code / Dimensions

Code
016
025
032
040
050
063
080
100

Cover

Nominal Cover with


Without
size
X-connection auxilliary
and gauge
function
port G"

Orifice

Seal

Design
series
(not required
for ordering)

Size
NG16
NG25
NG32
NG40
NG50
NG63
NG80
NG100

Code
N
V

Seal
NBR
FPM

Code
Orifice
99
Without orifice, open
M

For orifice recommendations, bolt and seal kits see


"Accessories" in this chapter.

Z1 C Z2

Orifice position

Dimensions
NG16 to NG63

NG80 to NG100
Gauge port G"

Gauge port G"

Orifice Y

Orifice

Z1

Z1

Z2
Z2
B
B

Ports Y, Z1 and Z2: O-ring recess diameter on valve body


Size
NG16
NG25
NG32
NG40
NG50
NG63
NG80
NG100

B
65
85
102
125
140
180
250
300

L
36
45
50
60
70
85
105
120

Orifice thread
1/16 NPT
1/16 NPT
1/16 NPT
1/8 NPT
1/8 NPT
1/8 NPT
1/8 NPT
1/8 NPT

Weight [kg]
0.9
1.9
2.9
5.3
8.5
15.5
34
58

CE-C UK.INDD CM 28.08.13

8-8

Parker Hannifin Corporation


Hydraulics Group

2 Way Slip-In Cartridge Valves


Series C*B, Cover with Stroke Limiter

Catalogue HY11-3500/UK

Ordering Code / Dimensions

C
Cover

Code
016
025
032
040
050
063
080
100

Nominal Cover with Adjustment Orifice


size
X-connection
screw/
and stroke
spindle
limiter

Seal

Design
series
(not required
for ordering)

Size
NG16
NG25
NG32
NG40
NG50
NG63
NG80
NG100

Code
N
V

Seal
NBR
FPM

Code
Orifice
99
Without orifice, open

M
1

For orifice recommendations, bolt and seal kits see


"Accessories" in this chapter.

X Z1 C Z2
Orifice position

Dimensions NG16 - NG25


max.L 2

L1

Gauge port

X
Orifice

Z1

1cm
M16

Z2
4

Ports Y, Z1 and Z2: O-ring recess diameter on valve body

Size
NG16
NG25

B
65
85

L1
36
45

L2 max.
72
72

Gauge port

Orifice thread

G 1/4"

M6

Weight [kg]
0.9
1.9

CE-C UK.INDD CM 28.08.13

8-9

Parker Hannifin Corporation


Hydraulics Group

2 Way Slip-In Cartridge Valves


Series C*B, Cover with Stroke Limiter

Catalogue HY11-3500/UK

Dimensions
Dimensions NG32 - NG50

Ports Y, Z1 and Z2: O-ring recess diameter on valve body

Dimensions NG63

Dimensions NG80-100

L2

max.L2

1cm

L1

L1

Gauge port
Gauge port
X
Orifice

Orifice

Z1
Z1

X
Z2
4

Z2

Ports Y, Z1 and Z2: O-ring recess diameter on valve body


Size
NG32
NG40
NG50
NG63
NG80
NG100

B
102
125
140
180
250
300

L1
50
60
70
85
105
120

L2 max.
48
50
50
65
95
120

Gauge port
G"
G"
G"
G"
G"
G"

Orifice thread
1/16 NPT
1/16 NPT
1/16 NPT
1/8 NPT
1/8 NPT
1/8 NPT

Weight [kg]
2.91
5.39
8.41
15.1
34.0
60.0

CE-C UK.INDD CM 28.08.13

8-10

Parker Hannifin Corporation


Hydraulics Group

2 Way Slip-In Cartridge Valves


Series C*C, Cover f. Pilot System Mounting

Catalogue HY11-3500/UK

Ordering Code / Dimensions

Cover
for pilot
system
mounting

Without
auxilliary
function

1
Cover

Code
016
025
032
040
050
063
080
100

Nominal
size

Orifice /
choke

4
Seal

Design
series
(not required
for ordering)

Size
NG16
NG25
NG32
NG40
NG50
NG63
NG80
NG100

Code
N
V

Seal
NBR
FPM

Code
Orifice
99
Without orifice, open
00
Plug
NG16 to NG40
P A

Attention:
For NG50 and larger:
If pilot system NG06 should be used, mount adapter plate
PADA 1007/A-B/B-A or PADA 1007/A-A/B-B (NG10 to
NG06) see "Accessories" in this chapter.
For orifice recommendations, bolt and seal kits see
"Accessories" in this chapter.

X Z1 C
Z2 Y
NG50 to NG100
P
A
B
T

X Z2

4
Z1 Y

Orifice position

8
Dimensions NG16

CE-C UK.INDD CM 28.08.13

8-11

Parker Hannifin Corporation


Hydraulics Group

Catalogue HY11-3500/UK

Dimensions

2 Way Slip-In Cartridge Valves


Series C*C, Cover f. Pilot System Mounting

Dimensions NG25 to NG40

Dimensions NG50 to NG63

CE-C UK.INDD CM 28.08.13

8-12

Parker Hannifin Corporation


Hydraulics Group

2 Way Slip-In Cartridge Valves


Series C*C, Cover f. Pilot System Mounting

Catalogue HY11-3500/UK

Dimensions
Dimensions NG80 to NG100

8
Size
NG16
NG25
NG32

L
1)

79
85
102

40
45
50

Gauge port Weight [kg]


G"
G"
G"

1.0
1.9
2.9

Orifice thread
1

M5
M5
M5

M5
M5
M5

M5
M6
M6

M5
M6
M6

M5
M6
M6

M5
M6
M6

NG40

125

60

G"

5.3

M5

M5

M6

M6

M6

M6

NG50
NG63
NG80
NG100

140
180
250
300

70
85
105
120

G"
G"
G"
G"

8.5
15.3
34
60

M6
M6
1/16 NPT
1/16 NPT

M6
M6
1/16 NPT
1/16 NPT

M8
M8
1/8 NPT
1/8 NPT

M8
M8
1/8 NPT
1/8 NPT

M8
M8
1/8 NPT
1/8 NPT

M8
M8
1/8 NPT
1/8 NPT

1)

Width 65 mm.

CE-C UK.INDD CM 28.08.13

8-13

Parker Hannifin Corporation


Hydraulics Group

2 Way Slip-In Cartridge Valves


Series C*F, Cover with Pressure Valve

Catalogue HY11-3500/UK

Ordering Code / Dimensions

F
1

Cover

Code
016
025
032
Code
07
10
17
21
25
35

Nominal
size

Cover with Pressure


Pressure
pressure
range
adjustment
relief valve

Orifice /
choke

Seal

Design
series
(not required
for ordering)

Size
NG16
NG25
NG32

Code
N
V

Pressure range
[bar]
75
105
175
210
250
350

Seal
NBR
FPM

Code
Orifice
99
Without orifice, open

2
X

1
Z1

Z2

Orifice position
Code
Adjustment
S
Hand knob (standard)
A
Acorn nut with lead seal
L
Cylinder lock

For orifice recommendations, bolt and seal kits see


"Accessories" in this chapter.

Dimensions

Ports Z1 and Z2: O-ring recess diameter on valve body

1)

Size

L1

L2 max.

L3

L4

NG16
NG25
NG32

65 1)
85
102

40
45
50

32.5
42.5
51

114
102
95

125.5
114
106

117
105
97.5

Orifice thread
M5
M5
M6

M4
M5
M6

M5
M5
M6

Width 79 mm.

CE-C UK.INDD CM 28.08.13

8-14

Parker Hannifin Corporation


Hydraulics Group

2 Way Slip-In Cartridge Valves


Series C*G, Cover with Pressure Valve

Catalogue HY11-3500/UK

Ordering Code / Dimensions

G
1

Cover

Code
016
025
032
Code
07
10
17
21
25
35

Nominal
size

Size
NG16
NG25
NG32

Cover with Pressure


Pressure
pressure
range
adjustment
relief valve
and pilot
system
mounting

Orifice /
choke

4
Seal

Design
series
(not required
for ordering)

Code
N
V

Pressure range
[bar]
75
105
175
210
250
350

Seal
NBR
FPM

Code
Orifice
99
Without orifice, open
P

2
3
X

1
Z1

Z2

Orifice position

Code
Adjustment
S
Hand knob (standard)
A
Acorn nut with lead seal
L
Cylinder lock

For orifice recommendations, bolt and seal kits see


"Accessories" in this chapter.
Dimensions

Ports Z1 and Z2: O-ring recess diameter on valve body

1)

Size

L1

L2 max.

L3

L4

NG16
NG25
NG32

65 1)
85
102

40
45
50

32.5
42.5
51

114
102
95

125.5
114
106

117
105
97.5

Orifice thread
M5
M5
M6

M5
M5
M6

M4
M5
M6

M5
M5
M6

Width 79 mm.

CE-C UK.INDD CM 28.08.13

8-15

Parker Hannifin Corporation


Hydraulics Group

2 Way Slip-In Cartridge Valves


Series C*H, Cover with Stroke Limiter

Catalogue HY11-3500/UK

Ordering Code / Dimensions


Ordering code

N
1

Cover

Code
016
025
032
040
050
063
080
100

Size
NG16
NG25
NG32
NG40
NG50
NG63
NG80
NG100

Nominal
size

Stroke
limiter and
DC valve
mounting
pattern

Screws
with lock
nut

Orifice /
choke

4
Seal
NBR

Design
series
(not required
for ordering)

Code
Orifice
99
Without orifice, open
00
Plug

Attention:
For NG63, 80 and 100:
If pilot system NG06 should be used, mount adapter plate
PADA 1007/A-B/B-A or PADA 1007/A-A/B-B (NG10 to
NG06), see "Accessories" in this chapter.
For orifice recommendations, bolt and seal kits see
"Accessories" in this chapter.

Orifice position

Dimensions NG16

CE-C UK.INDD CM 28.08.13

8-16

Parker Hannifin Corporation


Hydraulics Group

Catalogue HY11-3500/UK

Dimensions

2 Way Slip-In Cartridge Valves


Series C*H, Cover with Stroke Limiter

Dimensions NG25 to NG63

CE-C UK.INDD CM 28.08.13

8-17

Parker Hannifin Corporation


Hydraulics Group

2 Way Slip-In Cartridge Valves


Series C*H, Cover with Stroke Limiter

Catalogue HY11-3500/UK

Dimensions
Dimensions NG80 to NG100

Size

B1

h1

Gauge port

NG16
NG25
NG32
NG40
NG50
NG63
NG80
NG100

65
85
102
125
140
180
250
300

119
144

125
114
132.5
142
147.5
161
215
240

85
85
85
85
85
110
120
120

76
70
56
50
60
75
94
85

27
36.5
47.5
64
72.5
90
122
145

G1/4
G1/4
G1/4
G1/4
G1/4
G1/4
G1/4
G1/4

Orifice thread
1

M5
M6
M6
M6
M8
M8
1/8 NPT
1/8 NPT

M5
M6
M6
M6
M8
M8
1/8 NPT
1/8 NPT

M5
M6
M6
M6
M8
M8
1/8 NPT
1/8 NPT

M5
M6
M6
M6
M8
M8
1/8 NPT
1/8 NPT

CE-C UK.INDD CM 28.08.13

8-18

Parker Hannifin Corporation


Hydraulics Group

2 Way Slip-In Cartridge Valves


Series C*V, Cover with Shuttle Valve

Catalogue HY11-3500/UK

Ordering Code / Dimensions


Ordering code

A
1

Cover

Code
016
025
032
040
050
063

Nominal Cover with


w/o
size
additional
shuttle
option
valve

Orifice /
choke

Seal

Design
series
(not required
for ordering)

Size
NG16
NG25
NG32
NG40
NG50
NG63

Code
N
V

Seal
NBR
FPM

Code
Orifice
99
Without orifice, open

For orifice recommendations, bolt and seal kits see


"Accessories" in this chapter.
X

Dimensions

Z1 C Z2

A T B

Orifice position

Section A-A

4
1

8
X

Z1

Z2
4

L1

Port Z2: O-ring recess diameter on valve body

Size

L1

NG16
NG25
NG32
NG40
NG50
NG63

65
85
102
125
140
180

86.5
91.5
96.5
106.5
126.5
141

85
85
102
125
140
180

Orifice thread
M5
M5
M5
M6
M8
M8

M5
M5
M5
M6
M8
M8

M5
M5
M5
M6
M8
M8

M5
M5
M5
M6
M8
M8

CE-C UK.INDD CM 28.08.13

8-19

Parker Hannifin Corporation


Hydraulics Group

2 Way Slip-In Cartridge Valves


Series C*W, Cover with Shuttle Valve

Catalogue HY11-3500/UK

Ordering Code / Dimensions

A
1

Cover

Code
016
025
032
040
050
063

Nominal
size

Size
NG16
NG25
NG32
NG40
NG50
NG63

Cover with
w/o
shuttle
additional
valve and
option
pilot system
mounting

Orifice /
choke

Seal

Design
series
(not required
for ordering)

Code
N
V

Seal
NBR
FPM

Code
Orifice
99
Without orifice, open
P

For orifice recommendations, bolt and seal kits see


"Accessories" in this chapter.
X

Z1 C Z2

Orifice position

Dimensions

Port Z2: O-ring recess diameter on valve body

Size

L1

NG16
NG25
NG32
NG40
NG50
NG63

65
85
102
125
140
180

40
45
50
60
70
85

77.5
85
102
125
140
180

Orifice thread
M5
M5
M5
M6
M8
M8

M5
M5
M5
M6
M8
M8

M5
M5
M5
M6
M8
M8

M5
M5
M5
M6
M8
M8

CE-C UK.INDD CM 28.08.13

8-20

Parker Hannifin Corporation


Hydraulics Group

Anda mungkin juga menyukai