ERDOAN KAYHAN,
S. HAKMOLU, H. AYOLU, . . ARIKAN, . BAYAR,
I. ZKOAK
TURAN
Turk J Med
Sci
2012; 42 (2): 307-313
TBTAK
E-mail: medsci@tubitak.gov.tr
Original Article
doi:10.3906/sag-1010-1258
Aim: To determine if hypotension frequency changes when hyperbaric or isobaric formulations of bupivacaine, or their
sequential administrations, are used for cesarean section. Hypotension after spinal anesthesia for cesarean section is
common.
Materials and methods: A total of 144 patients who were to undergo cesarean section with spinal anesthesia were
allocated into 4 groups. Spinal anesthesia was achieved with 10 mg of hyperbaric bupivacaine in Group H10, sequential
5-mg administrations of hyperbaric and isobaric bupivacaine in Group H5P5, sequential 5-mg administrations of
isobaric and hyperbaric bupivacaine in Group P5H5, and 10 mg of isobaric bupivacaine in Group P10. Hemodynamic
parameters were determined and the incidence of hypotension, incidence of bradycardia, and amount of ephedrine
required to treat hypotension were recorded. Fetal Apgar scores, the pH of the umbilical cord blood, and side effects
were also noted.
Results: American Society of Anesthesiologists risk group, surgical duration, and demographic values were similar
among the groups. The incidence of hypotension was found to be 69.4%, 66.7%, 75.0%, and 83.3% in the H10, H5P5, P10,
and P5H5 groups, respectively. The incidences of hypotension were not significantly different. Bradycardia incidence,
ephedrine consumption, the pH of cord blood, and side effects were not different among the groups.
Conclusion: When the dose of local anesthetic is the same, the incidence of spinal-induced hypotension cannot be
lowered using hyperbaric, isobaric, or sequential injections of a half dose of bupivacaine for spinal anesthesia during
cesarean section.
Key words: Baricity, bupivacaine, spinal anesthesia, cesarean section
1
2
307
Introduction
Spinal anesthesia has become an increasingly popular
technique for cesarean section in many countries
over the last few decades. However, the rapid onset
of sympathetic block and subsequent hypotension
remains a major clinical concern when using the
technique. In order to decrease the incidence and
severity of hypotension, various attempts have been
made to modify the technique and the dose of local
anesthetic used (1,2). However, spinal-induced
hypotension is the most important side effect, with
a reported incidence between 20% and 100% (3-5).
Recently, Cesur et al. (6) demonstrated a marked
decrease in the incidence of hypotension when 5 mg
of isobaric bupivacaine was followed by 5 mg of heavy
bupivacaine for spinal anesthesia during cesarean
section. They reported that the maternal hypotension
frequency decreased from 67% to 14% when 5 mg
of isobaric and 5 mg of hyperbaric bupivacaine were
used sequentially instead of 10 mg of hyperbaric
bupivacaine (7,8). In light of the study mentioned
above, we hypothesized that sequential injections of
isobaric and hyperbaric bupivacaine would decrease
the incidence of hypotension. Therefore, this study
was designed to compare the hemodynamic effects
of hyperbaric solutions, isobaric solutions, and the
sequential administration of hyperbaric and isobaric
solutions during cesarean section. The primary
outcome was the incidence of hypotension.
Materials and methods
After obtaining the approval of the institutional ethics
committee and the informed consent of patients, 144
patients in American Society of Anesthesiologists
308
Group H5P5
(n = 36)
Group P10
(n = 36)
Group P5H5
(n = 36)
28.47 5.07
28.38 5.23
28.08 4.88
27.69 5.96
0.924
75.30 11.37
77.50 11.21
74.83 12.21
71.58 7.63
0.140
161.77 6.44
160.75 5.35
159.75 4.12
160.77 5.46
0.473
27/9
30/6
30/6
27/9
0.786
44.58 15.50
45.13 11.30
41.86 9.10
40.44 8.33
0.253
Group H5P5
(n = 36)
Group P10
(n = 36)
Group P5H5
(n = 36)
21/15
24/12
18/18
17/19
0.337
T3 (C8-T6)
T4 (C8-T6)
T3 (C8-T5)
T4 (C8-T6)
0.176
T4 (T2-T8)
T5 (T1-T8)
T4 (T1-T6)
T5 (T1-T8)
0.063
9.47 3.57
10.05 3.56
11.22 3.32
9.36 4.01
0.118
3 (2-3)
3 (2-3)
3 (2-3)
3 (2-3)
0.520
L2-3/L3-4 (n)
0.813
Good (n)
33
32
33
31
Fair (n)
Poor (n)
41.86 19.88
46.80 23.40
48.14 20.56
48.90 29.60
0.761
134.86 38.57
145.83 32.43
151.81 29.74
146.67 27.90
0.161
131.87 40.69
134.46 39.96
130.17 42.85
144.16 78.31
0.742
Group H5P5
(n = 36)
Group P10
(n = 36)
Group P5H5
(n = 36)
Apgar, 1 min
8.83 1.38
8.70 1.14
8.47 1.31
9.01 0.98
0.311
Apgar, 5 min
9.86 0.35
9.70 0.46
9.72 0.74
9.69 0.52
0.543
Fetal pH
7.30 0.07
7.29 0.05
7.28 0.06
7.31 0.07
0.102
Group H5P5
(n = 36)
Group P10
(n = 36)
Group P5H5
(n = 36)
Hypotension (n, %)
25 (69.4%)
24 (66.7%)
27 (75.0%)
30 (83.3%)
0.539
Nausea (n, %)
8 (22.2 %)
10 (27.8%)
15 (41.7%)
18 (50%)
0.092
0 (0%)
3 (8.3%)
3 (8.3%)
6 (16.7%)
0.144
3 (8.3%)
5 (13.9%)
2 (5.6%)
2 (5.6%)
0.536
12.08 13.11
12.36 15.09
11.94 13.16
13.88 12.98
0.926
Vomiting (n, %)
Bradycardia (n, %)
Ephedrine requirement (mg) (mean SD)
H5P5
P10
P5H5
Fentanyl (n, %)
4 (11.1%)
7 (19.4%)
6 (16.7%)
9 (25.0%)
0.486
Propofol (n, %)
6 (16.7%)
4 (11.1%)
4 (11.1%)
8 (22.2%)
0.501
9 (25.0%)
7 (19.4%)
8 (22.2%)
12 (33.3%)
0.557
Discussion
The results of our study have demonstrated
that spinal anesthesia performed with 10 mg of
hyperbaric bupivacaine, isobaric bupivacaine, or a
sequential administration of a hyperbaric-isobaric
bupivacaine combination did not cause a difference
in hypotension frequency.
Previous studies with hyperbaric bupivacaine
for spinal anesthesia during cesarean section
yielded hypotension frequencies ranging from
4.5% (9) to 100% (10). In an early study by Santos
et al. (9), 7.5 to 10 mg (depending on the patients
height) of hyperbaric bupivacaine was used for
References
1.
2.
3.
312
Ngan Kee WD, Khaw KS, Lee BB, Lau TK, Gin T. A doseresponse study of prophylactic intravenous ephedrine for
the prevention of hypotension during spinal anesthesia for
cesarean delivery. Anesth Analg 2000; 90: 1390-5.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
313