Anda di halaman 1dari 18

R 21 CE

1mm Thick Self-Smoothing Epoxy Floor


System
Features
Hard wearing - durable with low maintenance costs
Resistant to a wide range of chemicals and liquids
Seamless - easily cleaned to maintain high standards of hygiene
Self-smoothing properties provide a flat high gloss finish
Conforms to the overall migration standards laid down in 21 CFR 175-300
of US - FDA certified by CFTRI

STANDARD COLOURS
Available to any standard RAL Card upon request

ARDEX ENDURA (INDIA) PRIVATE LIMITED


Corporate Office & Regd. Office:
Unit No. 406 & 407, Brigade Rubix,
No. 20, HMT Campus, Yeshwanthapur Hobli,
Bengaluru - 560013. Karnataka, INDIA.
CIN No: U24233KA1997PTC022383
Tel: +91 80 66746500
Fax: +91 80 66746540
Email: customercare@ardexendura.com
Visit us: www.ardexendura.com

R 21 CE
1mm Thick Self-Smoothing Epoxy Floor System
DESCRIPTION

A specialist applied, self-smoothing, epoxy resin


floor finish combining outstanding wearing
properties with chemical resistance and
decorative properties. Ideally suited in areas
where a seamless, joint free finish is required
and maximum cleanliness is essential.
Laboratories, clean rooms, and general light
industry are just some of the environments
that can benefit from this system.
SURFACE PREPARATION

It is essential that R 21 CE is applied to sound,


clean and dry surfaces to ensure maximum
adhesion.
R 21 CE is designed for use as a thin coat
application at internal situation which is not
exposed to sunlight.
If applied at exposed situation where direct or
indirect sunlight falls, floor will undergo the
yellowing effect.
NOTE: Thin coatings will reflect the surface
texture of the substrates and as such high
spots may lead to premature wear of the
coating, thus surface preparation techniques
should be chosen appropriately. The ideal
substrate for application is a flat, lightly
textured, clean concrete surface.
SUBSTRATE PREPARATION

The concrete surface must be hard, sound and


free of dust, oil, polish, wax, greases and other
barrier materials such as paint, lime coatings,
plaster, curing agents, laitance, adhesive
residues etc., that will inhibit adhesion to the
substrate.
Use a suitable degreaser to remove polish,
wax, grease, oil and similar contaminating
substances prior to mechanical preparation.
Contaminated concrete surfaces should be
mechanically prepared, either by scabbling,
grinding or contained shot blasting equipment
or similar, and be vacuumed clean prior to
applying R 3 E. Overwatered or otherwise weak
concrete surfaces must also be suitably
prepared down to sound, solid concrete by
mechanical methods. Dust and other debris
should be removed using vacuum equipment.
NOTE: Any joints or cracks in the concrete
base where differential movement is anticipated
e.g. movement joints, should be brought
through to the finished surface. New concrete
slabs must be allowed to cure for at least
14 days. Moisture in the substrate shall be less
than 5 %.
PRIMING

All areas to be treated with R 21 CE must first


be primed with ARDEX ENDURA R 3 E. One or
more coats of primer may be required
depending upon the condition and porosity of
the concrete substrate. High porosity
substrates may be revealed after preparation
and will be evident by their rapid suction and

absorption. If in doubt use two coats of


ARDEX ENDURA R 3 E. Poorly primed surfaces
may lead to blistering or pin holing in the cured
resin. Allow for over night drying

PROPERTIES

The values shown are typical of results


obtained in the laboratory at 27 1C. Actual
performance values obtained on site may vary
from those quoted.

MIXING

The individual contents of the R 21 CE should


be thoroughly stirred before being mixed
together. Mix Part D with Part A. Ensure smooth
mixing. The entire contents should be poured in
to a larger mixing vessel to incorporate the
Part B and Part C. The four materials are mixed
thoroughly with a spiral mixing paddle in a slow
speed drill. The mixing of all the four should
continue for 1 minute until a consistent
homogenous mix is achieved. One or more
packs may be mixed simultaneously to ensure a
quick rate of installation.
NOTE: Once mixed, the R 21 CE will generate
heat and lose working time if it is left in the
mixing container or otherwise kept in bulk.
APPLICATION

The mixed R 21 CE material should be applied


to the prepared and over night dried primed
surface without delay using a trowel or depth
set rake to achieve the desired thickness. As
soon as the R 21 CE has been laid and as work
progresses, the surface should be gently rolled
with a spiked roller in order to release any
entrapped air from the mix also to blend out any
trowel marks. The work area should be
protected during the installation process and
during the initial curing time to ensure that no
debris can contaminate the surface of the resin,
as this will lead to unwanted blemishes in the
hardened, cured surface.
LIMITATIONS

R 21 CE should not be applied to floors that are


known to have rising moisture or have relative
humidity of greater than 75% at the time of
application. These products should not be
applied in temperatures less than 10C or
where the ambient relative humidity is greater
than 85%. Do not steam clean or use hot water
above 55C to wash the surface.
NOTE: All

products are manufactured under


strict Quality Assurance procedures, however
it is recommended that where colour
consistency is essential, wherever possible,
products from one batch should be used.
CLEANING

R 21 CE can be removed from tools and


equipment by using ARDEX ENDURA RTC 100
immediately after use. Any hardened material
will need to be removed mechanically.

PHYSICAL PROPERTIES

R 21 CE

@ 27 1C

Pot life

30 mins

Mixed Density

1.55 - 1.60 gm/cc

Initial hardness

24 hours

Full cure

7 days

Bond strength

>1.5 N/mm

Compressive strength
BS 6319 (P2)

>50 N/mm

Flexural strength
BS 6319 (P3)

>25 N/mm

Tensile strength
BS 6319 (P2)

>20 N/mm

Shore D Hardness

> 70

COVERAGE ESTIMATES

Pack size

Coverage

16.50kg

Approximately
10.5 m @1mm thick

Part A 5kg
Part B 2kg
Part C 9kg
Part D 500g

These figures are theoretical, due to


the wastages and the variety and nature of
substrates practical coverage figures may be
reduced.
NOTE:

STORAGE AND SHELF LIFE

R 21 CE has a shelf life of 12 months if kept in


a dry, store between 5C and 30C in the
original unopened containers. The product
should be protected from frost, away from
direct sunlight and sources of heat.
CHEMICAL RESISTANCE

R 21 CE is resistant to a wide range of liquids


and chemicals, for specific information please
refer to the following ARDEX ENDURA
"Chemical Resistance" chart.

CHEMICAL RESISTANCE CHART SUMMARY OF RESULTS


Concentration
in %

R 21 CE

MAINTENANCE

Acetic acid

10

Acetic acid

50

Acetone

100

Ammonia

10

Ammonia

35

100

Citric acid

50

Formic acid

50

Hydrochloric
acid

25

Hydrogen
Peroxide

20vol

Kerosine

100

Lactic acid

25

Methylated
Spirit

100

Milk

100

Nitric acid

30

Nitric acid

70

Beer

R 21 CE is available to any standard RAL Card


colours upon request.
Good housekeeping and regular cleaning is
essential in order to maintain the performance
of R 21 CE. It is particularly importance in areas
that are subject to regular spillage of chemicals.
Spillages should not be allowed to dry, which
results in higher concentrations of the
chemicals, which may lead to early failure.
Regular cleaning of the surface with a rotary
scrubbing machine in conjunction with a water
miscible cleaning agent or hot water washing at
temperatures up to 50C is recommended.
PRECAUTIONS

In case of contact with the eyes, rinse


immediately with plenty of water and seek
medical advice and after contact with the skin
wash immediately with plenty of soap and water
(do not use solvents). Prolonged contact with
the skin should be avoided, especially where
the user has an allergic reaction to epoxide
materials. Always wear gloves and eye/face
protection is necessary. Observe personal
hygiene, particularly washing the hands after
work has been completed or at any interruption
whilst work is in progress. Care should be
taken when removing gloves to avoid
contaminating the insides. In case of accidents
seek medical advice.

Oleic acid

100

Orange Juice

100

DISPOSAL/SPILLAGE

Petrol

100

Spillage of any of the component products


should be absorbed onto sand or other inert
materials and transferred to a suitable
disposable vessel. Disposal of such spillage
or empty packaging should be in accordance
with local waste disposal authority regulations.

Phosphoric
acid

10

100

Saturated

Red Wine
Salt

For further information please refer to the


Material Safety Data Sheet.

Sodium
hydroxide

50

Sodium
hyperchlorite

15

Saturated

Sold subject to the Company's conditions


of sale which are available on request.

Sugar

CONDITIONS OF SALE

Sulphuric acid

10

NOTE

Sulphuric acid

25

Sulphuric acid

75

100

The information supplied in this datasheet


is based upon extensive experience and is
given in good faith in order to help you.
Our Company policy is one of continuous
Research and Development; we therefore
reserve the right to update this information
at any time without prior notice. We also
guarantee the consistent high quality of our
products; however as we have no control over
site conditions or the execution of the work,
we accept no liability for any loss or damage
which may arise as a result thereof.

Xylene

Resistant

28 Days +

Limited Resistance

up to 7 Days

Not Resistant

Short Term Resistance

up to 1 Day

Note: These results are based on immersion


testing and ARDEX ENDURA products may
appear less resistant when compared with
other manufacturer's surface swab test results.

02/15

Reagent

COLOURS

R 25 CE

Self-Smoothing Epoxy Floor System


Features
1-4mm thick smooth, tough and hard wearing - durable with low maintenance costs
Resistant to a wide range of chemicals and liquids
Seamless - easily cleaned to maintain high standards of hygiene
Self-smoothing properties provide a flat high gloss finish
Conforms to the overall migration standards laid down in 21 CFR 175-300 of US FDA certified by CFTRI

STANDARD COLOURS
Available to any standard RAL Card upon request

ARDEX ENDURA (INDIA) PRIVATE LIMITED


Corporate Office & Regd. Office:
Unit No. 406 & 407, Brigade Rubix,
No. 20, HMT Campus, Yeshwanthapur Hobli,
Bengaluru - 560013. Karnataka, INDIA.
CIN No: U24233KA1997PTC022383
Tel: +91 80 66746500
Fax: +91 80 66746540
Email: customercare@ardexendura.com
Visit us: www.ardexendura.com

R 25 CE
Self-Smoothing Epoxy Floor System
DESCRIPTION

MIXING

PROPERTIES

A specialist applied, 1-4mm thick,


self-smoothing, epoxy resin floor finish
combining outstanding wearing properties with
chemical resistance and decorative properties.
Ideally suited in areas where a seamless, joint
free finish is required and maximum cleanliness
is essential. Laboratories, clean rooms, and
general light industry are just some of the
environments
that can benefit from this system.

The values shown are typical of results


obtained in the laboratory at 27 1C. Actual
performance values obtained on site may vary
from those quoted.

It is essential that R 25 CE is applied to sound,


clean and dry surfaces to ensure maximum
adhesion.

The individual contents of the R 25 CE should


be thoroughly stirred before being mixed
together. Mix Part D with Part A. Ensure smooth
mixing. The entire contents should be poured in
to a larger mixing vessel to incorporate the
Part B and Part C. The four materials are mixed
thoroughly with a spiral mixing paddle in a slow
speed drill. The mixing of all the four should
continue one minute until a consistent
homogenous mix is achieved. One or more
packs may be mixed simultaneously to ensure a
quick rate of installation.
NOTE: Once mixed, the R 25 CE will generate
heat and lose working time if it is left in the
mixing container or otherwise kept in bulk.

NOTE: Thin

APPLICATION

SURFACE PREPARATION

coatings will reflect the surface


texture of the substrates and as such high
spots may lead to premature wear of the
coating, thus surface preparation techniques
should be chosen appropriately. The ideal
substrate for application is a flat, lightly
textured, clean concrete surface.
SUBSTRATE PREPARATION

The concrete surface must be hard, sound and


free of dust, oil, wax, polish, grease and other
barrier materials such as paint, lime coatings,
plaster, curing agents, laitance, adhesive
residues etc., that will inhibit adhesion to the
substrate.
Use a suitable degreaser to remove polish,
wax, grease, oil and similar contaminating
substances prior to mechanical preparation.
Contaminated concrete surfaces should be
mechanically prepared, either by scrubbling,
grinding or contained shot blasting equipment
or similar, and be vacuumed clean prior to
applying primer. Overwatered or otherwise
weak concrete surfaces must also be suitably
prepared down to sound, solid concrete by
mechanical methods. Dust and other debris
should be removed using vacuum equipment.
NOTE: Any joints or cracks in the concrete
base where differential movement is anticipated
e.g. movement joints, should be brought
through to the finished surface. New concrete
slabs must be allowed to cure for at least
14 days.
PRIMING

All areas to be treated with R 25 CE must first


be primed with ARDEX ENDURA R 3 E Primer.
One or more coats of primer may be required
depending upon the condition and porosity
of the concrete substrate. High porosity
substrates may be revealed after preparation
and will be evident by their rapid suction and
absorption. If in doubt use two coats of
ARDEX ENDURA R 3 E Primer. Poorly primed
surfaces may lead to blistering or pin holing in
the cured resin.

The mixed R 25 CE material should be applied


to the prepared and primed surface without
delay using a trowel or depth set rake to
achieve the desired thickness. As soon as the
R 25 CE has been laid and as work progresses,
the surface should be gently rolled with a spiked
roller in order to release any entrapped air from
the mix also to blend out any trowel marks.
The work area should be protected during the
installation process and during the initial curing
time to ensure that no debris can contaminate
the surface of the resin, as this will lead to
unwanted blemishes in the hardened, cured
surface.
LIMITATIONS

R 25 CE should not be applied to floors that


are known to have rising moisture or have
relative humidity of greater than 75% at the
time of application. These products should not
be applied in temperatures less than 10C or
where the ambient relative humidity is greater
than 85%. Should it be determined that moisture
is present in the concrete then the entire
surface should be treated with an effective
Suitable Damp Proof Membrane. Once the mixed
material has exceeded its pot life, the viscosity
and the characteristics of the product will
change and any unused product should be
discarded at this time. Do not steam clean or
use hot water above 55C to wash the surface.
Do not install R 25 CE at floors which are
exposed to direct or indirectly to the sunlight as
they undergoes the yellowing effect.
NOTE: All products are manufactured under
strict Quality Assurance procedures, however
it is recommended that where colour
consistency is essential, wherever possible,
products from one batch should be used.

CLEANING

R 25 CE can be removed from tools and


equipment by using ARDEX ENDURA RTC 100
immediately after use. Any hardened material
will need to be removed mechanically.

PHYSICAL PROPERTIES

R 25 CE

@ 27 1C

Pot life

30 mins

Initial hardness

24 hours

Full cure

7 days

Bond strength

> 1.5 N/mm

Compressive strength

70 N/mm

Flexural strength

31 N/mm

Tensile strength

23 N/mm

Shore D Hardness

> 70

COVERAGE ESTIMATES

Pack size

Coverage

16kg

Approximately
4.86 m @ 2 mm
thick

Part A 3.80kg
Part B 1.70kg
Part C 10kg
Part D 500g
Mixed Density

1.62 - 1.67 gm/cc

11kg

Approximately

Part A 3.80kg
Part B 1.70kg
Part C 5kg
Part D 500g
Mixed Density

7.5 m @ 1 mm

thick

1.45 - 1.50 gm/cc

These figures are theoretical, due to


the wastages and the variety and nature of
substrates practical coverage figures may be
reduced.
NOTE:

STORAGE AND SHELF LIFE

R 25 CE has a shelf life of 12 months if kept


in a dry, store between 5C and 30C in the
original unopened containers. The product
should be protected from frost, away from
direct sunlight and sources of heat.
CHEMICAL RESISTANCE

R 25 CE is resistant to a wide range of liquids


and chemicals, for specific information please
refer to the following ARDEX ENDURA
"Chemical Resistance" chart.

CHEMICAL RESISTANCE CHART SUMMARY OF RESULTS


Concentration
in %

R 25 CE

MAINTENANCE

Acetic acid

10

Acetic acid

50

Acetone

100

Ammonia

10

Ammonia

35

100

Citric acid

50

Formic acid

50

Hydrochloric
acid

25

Hydrogen
Peroxide

20vol

Kerosine

100

Lactic acid

25

Methylated
Spirit

100

Milk

100

Nitric acid

30

Nitric acid

70

Beer

R 25 CE is available to any standard RAL Card


colours upon request.
Good housekeeping and regular cleaning is
essential in order to maintain the performance
of R 25 CE. It is particularly importance in areas
that are subject to regular spillage of chemicals.
Spillages should not be allowed to dry, which
results in higher concentrations of the
chemicals, which may lead to early failure.
Regular cleaning of the surface with a rotary
scrubbing machine in conjunction with a water
miscible cleaning agent or hot water washing
at temperatures up to 50C is recommended.
PRECAUTIONS

In case of contact with the eyes, rinse


immediately with plenty of water and seek
medical advice and after contact with the skin
wash immediately with plenty of soap and water
(do not use solvents). Prolonged contact with
the skin should be avoided, especially where
the user has an allergic reaction to epoxide
materials. Always wear gloves and eye/face
protection is necessary. Observe personal
hygiene, particularly washing the hands after
work has been completed or at any interruption
whilst work is in progress. Care should be
taken when removing gloves to avoid
contaminating the insides. In case of accidents
seek medical advice.

Oleic acid

100

Orange Juice

100

DISPOSAL/SPILLAGE

Petrol

100

Spillage of any of the component products


should be absorbed onto sand or other inert
materials and transferred to a suitable
disposable vessel. Disposal of such spillage
or empty packaging should be in accordance
with local waste disposal authority regulations.

Phosphoric
acid

10

100

Saturated

Sodium
hydroxide

50

Sodium
hyperchlorite

15

Saturated

Sold subject to the Company's conditions


of sale which are available on request.

up to 75

NOTE

100

The information supplied in this datasheet


is based upon extensive experience and is
given in good faith in order to help you.
Our Company policy is one of continuous
Research and Development; we therefore
reserve the right to update this information
at any time without prior notice. We also
guarantee the consistent high quality of our
products; however as we have no control over
site conditions or the execution of the work,
we accept no liability for any loss or damage
which may arise as a result thereof.

Red Wine
Salt

Sugar
Sulphuric acid
Xylene

Resistant

28 Days +

Limited Resistance

up to 7 Days

Not Resistant

Short Term Resistance

up to 1 Day

Note: These results are based on immersion


testing and ARDEX ENDURA products may
appear less resistant when compared with
other manufacturer's surface swab test results.

For further information please refer to the


Material Safety Data Sheet.
CONDITIONS OF SALE

05/15

Reagent

COLOURS

Draft Copy : 04-07-2013

R 35 CE

Solvent Free High Build Epoxy Coating

HIGH PERFORMANCE, EPOXY RESIN FLOOR COATING, SUPPLIED AS TWO PARTS IN


PRE-MEASURED PACKS FOR EASE OF ON SITE MIXING AND USE. THE CURED RESIN
FORMS A TOUGH, EASILY CLEANED COATING

Features
Hard wearing - durable with low maintenance costs
Resistant to a wide range of chemicals and liquids
Easily cleaned
Provides a high gloss finish
Conforms to the overall migration standards laid down in 21 CFR 175-300 of US FDA certified by CFTRI

STANDARD COLOURS
Available to any standard RAL Card upon request

ARDEX ENDURA (INDIA) PRIVATE LIMITED


Corporate Office & Regd. Office:
Unit No. 406 & 407, Brigade Rubix,
No. 20, Yeshwanthapur Hobli, HMT Campus,
Bangalore - 560022. Karnataka, INDIA.
CIN No: U24233KA1997PTC022383
Tel: +91 80 66746500
Fax: +91 80 66746540
Email: customercare@ardexendura.com
Visit us: www.ardexendura.com

R 35 CE
Solvent Free High Build Epoxy Coating
HIGH PERFORMANCE, EPOXY RESIN FLOOR COATING, SUPPLIED AS TWO PARTS IN PRE-MEASURED PACKS FOR
EASE OF ON SITE MIXING AND USE. THE CURED RESIN FORMS A TOUGH, EASILY CLEANED COATING
DESCRIPTION

MIXING

To provide a tough, hard wearing, easily


cleaned surface in industrial environments
where a degree of higher resistance to
chemical attack is required. It is suitable for
use in workshops, production and processing
areas, dairies, soft drinks and bottling plants,
breweries, kitchens any floor areas subject to
wet working and possible chemical spillage.

The individual contents of the R 35 CE should


be thoroughly stirred before being mixed
together. The entire contents of Part B should
be poured into Part A and the two materials
mixed thoroughly for at least 3 minutes using
a heavy duty slow speed drill with spiral paddle.
Some of the mixed components should be
reintroduced back into the hardener container
in order to activate any residue and then poured
back into the larger mixing vessel and re-mixed
for 30 seconds. Mixing in this way will ensure
product consistency and that any resin that
remains in the containers after application will
cure to provide for easier waste disposal.
NOTE: Once mixed, the R 35 CE will generate
heat and lose working time if it is left in the
mixing container or otherwise kept in bulk.

SURFACE PREPARATION

It is essential that R 35 CE is applied to sound,


clean and dry surfaces to ensure maximum
adhesion.
R 35 CE is designed for use as a high build
200 - 250 micron application per coat.
NOTE: Thin coatings will reflect the surface
texture of the substrate and as such high
spots may lead to premature wear of coating,
thus surface preparation techniques should be
chosen appropriately. The ideal substrate for
application is a flat, lightly textured, clean
concrete surface. A two coat application is
recommended.

COATING

Once mixed the R 35 CE should be poured


directly onto the floor and distributed without
delay to the prepared surface using a brush
or short/medium pile roller. Ensure that the
entire surface is coated and that ponding'
of the material does not occur.

Use a suitable degreaser to remove polish,


wax, grease, oil and similar contaminating
substances prior to mechanical preparation.
Contaminated concrete surfaces should be
mechanically prepared, preferably either by
grinding or light contained shot blasting
equipment or similar, and be vacuumed clean
prior to applying R 35 CE. Overwatered or
otherwise weak concrete surfaces must also
be suitably prepared down to sound, solid
concrete by mechanical methods.
Dust and other debris should be removed
using vacuum equipment.
NOTE: Any joints or cracks in the concrete
base where differential movement is anticipated
e.g. movement joints, should be brought
through to the finished surface. New concrete
slabs must be allowed to cure for at least
6 weeks.
High porosity substrates may be revealed
after preparation and will be evident by their
rapid suction and absorption. In these cases
a priming coat of ARDEX ENDURA R 3 E
Solvent Free Epoxy Primer is advisable before
applying the R 35 CE. Dense, high porosity
surfaces typically provided by rapid setting
pumped screeds will require an appropriate
primer. For all proprietary products used as
substrates, please refer to the manufacturer's
instructions for advice on priming.

CLEANING

R 35 CE can be removed from tools and


equipment by using ARDEX ENDURA RTC 100
immediately after use. Any hardened material
will need to be removed mechanically.
PROPERTIES

The values shown are typical of results


obtained in the laboratory at 27 1C. Actual
performance values obtained on site may vary
from those quoted.
PHYSICAL PROPERTIES

R 35 CE

@ 27 1C

Pot life

30 minutes

Time between coats

8 - 24 hours

A second coat is applied as soon as the first


coat has initially dried (typically 12 to 18 hours).

Walkability

24 hours

Full cure

7 days

This time will vary depending upon the condition


of the surface and the ambient temperature.
Provision for ventilation and air movement will
be required. When using new rollers, ensure that
all loose fibres are removed prior to use, any
loose fibres released from the roller will cause
unsightly blemishes in the finished coating.

Dry film thickness


for two or more coats

200 microns per


coat

VOC Content

20 g/L

SUBSTRATE PREPARATION

The concrete surface must be hard, sound


and free of dust and other barrier materials
such as paint, lime coatings, plaster, curing
agents, laitance, adhesive residues, etc., that
will inhibit adhesion to the substrate.

product changes and any unused product


should be discarded at this time.
NOTE: All ARDEX ENDURA products are
manufactured under strict Quality Assurance
procedures, however, it is recommended where
colour consistency is essential, wherever
possible, products from one batch should be
used.

SLIP RESISTANT FINISH

A fine textured finish with improved slip


resistance may be achieved by the use of
Fine Aggregate. Following the application
of the first coat of R 35 CE a scatter of
Fine Aggregate should be applied into the
wet coating to seed the surface, taking care
to achieve a uniform distribution. The second
application of R 35 CE will then encapsulate
the fine aggregate.
NOTE: The coverage rate of the pack will be
reduced.
LIMITATIONS

These products should not be applied at


temperature less than 10C or where the
ambient relative humidity is greater than 85%.
Note: The rate of wear of this coating will be
increased in areas of concentrated foot and
vehicle traffic, in particular, doorways, work
benches, drinks dispenses etc. It is advisable
in such areas to provide for additional coats
product or specify a higher performance
treatment.
Once the mixed material has exceeded its pot
life the viscosity and the characteristics of the

COVERAGE ESTIMATES

Pack size

Coverage

6kg

15 - 20 m per pack
per coat at
200 microns.

Part A 4.95kg
Part B 1.05kg

These figures are theoretical, due


to wastage and the variety and nature of
substrates practical coverage figures may be
reduced. Marking out areas to be covered per
pack or for a number of packs provides a
method of ensuring the correct and uniform
coverage.
NOTE:

Safety Yellow coloured R 35 CE requires a


minimum application of two 200 micron coats
to provide adequate opacity and hiding power,
particularly over dark substrates.
STORAGE AND SHELF LIFE

R 35 CE has a shelf life of 12 months if kept


in a dry, store between 5C and 30C in the
original unopened containers. The product
should be protected from frost, away from
direct sunlight and sources of heat.
CHEMICAL RESISTANCE

R 35 CE is resistant to a wide range of liquids


and chemicals, for specific information please
refer to the following ARDEX ENDURA
"Chemical Resistance" chart.

CHEMICAL RESISTANCE CHART SUMMARY OF RESULTS


Reagent

Concentration
in %

R 35 CE

10

Acetic acid

50

Acetone

100

Ammonia

10

Ammonia

35

100

Citric acid

50

Formic acid

50

Hydrochloric
acid

25

Hydrogen
Peroxide

20vol

Kerosine

100

Lactic acid

25

Methylated
Spirit

100

Milk

100

Nitric acid

30

Nitric acid

70

Oleic acid

100

Orange Juice

100

Petrol

100

10

100

Saturated

Sodium
hydroxide

50

Sodium
hyperchlorite

15

Saturated

Red Wine

Sugar

Our Company policy is one of continuous


Research and Development; we therefore

Good housekeeping and regular cleaning is


essential in order to maintain the performance
of R 35 CE. It is particularly important in areas
that are subject to regular spillage. Spillages
should not be allowed to dry, which results in
higher concentrations of the materials, which
may lead to early failure. Regular cleaning of
the surface with a rotary scrubbing machine in
conjunction with a water miscible cleaning agent
or hot water washing at temperatures up to
50C is recommended.
PRECAUTIONS

Phosphoric
acid

Salt

R 35 CE is available to any standard RAL Card


colours upon request.
MAINTENANCE

Acetic acid

Beer

COLOURS

Sulphuric acid

10

Sulphuric acid

25

Sulphuric acid

75

100

Xylene

The hardener is classified as corrosive and the


epoxy resin can be irritating to the eyes and
skin, and may cause sensitization by contact.
They are considered harmful in contact with the
skin and if swallowed. During mixing and
application the following precautions should be
observed: ensure adequate ventilation and avoid
contact of the material with the eyes, nasal
passages, mouth and unprotected skin. Avoid
contact with the hands by wearing protective
gloves and by using, if necessary, a suitable
barrier cream.
In case of contact with the eyes, rinse
immediately with plenty of water and seek
medical advice and after contact with the skin
wash immediately with plenty of soap and water
(do not use solvents). Prolonged contact with
the skin should be avoided, especially where the
user has an allergic reaction to epoxide
materials. Always wear gloves and eye/face
protection as necessary. Observe personal
hygiene, particularly washing the hands after
work has completed or at any interruption whilst
work is in progress. Care should be taken when
removing gloves to avoid contaminating the
insides. In case of accidents seek medical
advice.
DISPOSAL/SPILLAGE

Spillage of any of the component products


should be absorbed onto sand or other inert
material and transferred to a suitable disposable
vessel. Disposal of such spillage or empty
packaging should be in accordance with local
waste disposal authority regulations.

Resistant

28 Days +

For further information please refer to the


Product Safety Data Sheet.

Limited Resistance

up to 7 Days

CONDITIONS OF SALE

Not Resistant

Short Term Resistance

Sold subject to the Company's conditions


of sale which are available on request.
up to 1 Day
NOTE

The information supplied in this datasheet


is based upon extensive experience and is
given in good faith in order to help you.
07/13

Note: These results are based on immersion


testing and ARDEX ENDURA products may
appear less resistant when compared with
other manufacturer's surface swab test results.

R 70 CP

Medium Duty Polyurethane Screed


HIGH PERFORMANCE, POLYURETHANE RESIN FLOORING SYSTEM, SUPPLIED AS FOUR PARTS
IN PRE-MEASURED PACKS FOR EASE OF ON SITE MIXING AND USE. THE CURED SYSTEM
FORMS A TOUGH, EASILY CLEANABLE, PIGMENTED LAYER FROM 2mm UP TO 5mm THICK.

Features
Hard wearing - extremely durable and abrasion resistant with low maintenance cost
Resistant to a wide range of chemicals and liquids
Seamless - easily cleanable to maintain high standards of hygiene

STANDARD COLOURS
Available to any standard RAL Card upon request

ARDEX ENDURA (INDIA) PRIVATE LIMITED


Corporate Office & Regd. Office:
Unit No. 406 & 407, Brigade Rubix,
No. 20, HMT Campus, Yeshwanthapur Hobli,
Bengaluru - 560013. Karnataka, INDIA.
CIN No: U24233KA1997PTC022383
Tel: +91 80 66746500
Fax: +91 80 66746540
Email: customercare@ardexendura.com
Visit us: www.ardexendura.com

R 70 CP
Medium Duty Polyurethane Screed
HIGH PERFORMANCE, POLYURETHANE RESIN FLOORING SYSTEM, SUPPLIED AS FOUR PARTS IN PRE-MEASURED PACKS FOR EASE OF ON SITE
MIXING AND USE. THE CURED SYSTEM FORMS A TOUGH, EASILY CLEANABLE, PIGMENTED LAYER FROM 2mm UP TO 5mm THICK.

DESCRIPTION

Specialist applied, polyurethane resin floor


finishes, combining outstanding wearing
properties with high chemical resistance and
pleasing decorative properties. Ideally suited
in aggressive areas where a seamless, joint
free finish is required and maximum cleanliness
is essential. Factories and general heavy duty
plant and traffic areas are just some of the
environments that can benefit from the tough
chemically resistant system.
SURFACE PREPARATION

The concrete or screed substrate must be


hard, sound, free of dust and other barrier
materials such as paint, lime coatings, plaster,
curing agents, laitance, adhesive residues, oil,
grease, wax, polish etc., that will inhibit
adhesion to the substrate.
Contaminated concrete surfaces should be
mechanically prepared, either by scrabbling,
grinding or contained shot blasting equipment
or similar, and be vacuumed clean prior to
applying R 70 CP. Overwatered or otherwise
weak concrete surfaces must also be suitably
prepared down to sound, solid concrete by
mechanical methods. Dust and other debris
should be removed using vacuum equipment.
NOTE: Any joints or cracks in the concrete
base where differential movement is anticipated
e.g. movement joints, should be brought
through to the finished surface and suitably
sealed. New concrete slabs must be allowed
to cure for at least 14 days.
To ensure maximum bond, grooves must be
cut into the perimeter of the sub-floor, typically
8 mm deep by 8 mm wide. These should be
inset approximately 100mm from and running
parallel with the walls and adjacent to
doorways and plinths etc., including any
finishing edges and day joints. The grooves
must have clean, square edges and the
product laid into the full depth of the groove
forming a perimeter anchorage. Grooves
should surround areas not exceeding 20 m.

seeded with Fine Aggregate at dosage of


1kg/sqm to aid application.
Alternatively priming can be achieved using a
nominal 1mm scratch coat of R 70 CP. Mix the
R 70 CP as per the data sheet, pour onto the
floor and spread thinly using a straight edge
trowel. Scratch off the excess with the edge of
the trowel and leave to cure for 16 hours or
overnight.
MIXING

The contents of Part A and Part B of R 70 CP


must first be mixed together for 1 minute, using
forced action, in a suitably sized mixing vessel.
The contents of Part C the powder component
and Part D pigment should then be introduced
into the mixed resin and mixed together for a
further 2 minutes to create one homogeneous
mix. One or more packs may be mixed at the
same time in order to maintain a quick rate of
installation.
APPLICATION

For flooring applications, the mixed material


should be applied to the primed/scratch coated
surface after 8 and 24 hours after
priming/scratch coating, using a trowel to
achieve the desired thickness. As soon as the
product has been laid and as work progresses,
the surface should be gently rolled with a spiked
roller in order to provide
an even surface appearance. Do not re-roll later.
The work area should be protected during the
installation process and during the initial curing
time to ensure that no airborne debris can
contaminate the surface of the wet resin as this
will lead to unwanted blemishes in the hardened,
cured surface.
All movement joints in the sub-floor must be
carried through the topping and properly sealed.
Construction joints and cracks not subject to
movement may be overlaid but should the floor
move in any way, these defects will reflect
through the system. Isolation joints will need
to be allowed for in areas where high thermal
movement is anticipated, e.g. around ovens and
freezers.

STEEL PLATES

Steel decking must be cleaned, sound and


properly supported to prevent flexing. Deck
plate of less than 4 mm thick is not
recommended. Surface should be shot blasted
to SA2.5 and primed using ARDEX ENDURA
R 3 E Solvent Free Epoxy Primer.
PRIMING

All appropriate substrates to receive R 70 CP


must first be primed with ARDEX ENDURA
R 3 E Solvent Free Epoxy Primer. One or more
coats of primer may be required depending
upon the condition and porosity of the concrete
substrate. The final coat of ARDEX ENDURA
R 3 E Solvent Free Epoxy Primer shall be

LIMITATIONS

R 70 CP should only be applied at temperature


above 5C and where the atmospheric relative
humidity (RH) is 90% or below. Floors should
have a RH of 75% or less. For floors with an RH
of more than 75%, the entire floor area should
be treated with effective Suitable Damp Proof
Membrane. The substrate should have a surface
tensile strength of at least 1.5 N/mm. R 70 CP
and primer/ an effective Suitable Damp Proof
Membrane may be applied to substrates of a
lower strength, but long-term performance may
be impaired. Once the mixed material has
exceeded its pot life, the viscosity and the
characteristics of the product will change and
any unused product should be discarded at
this time.

CLEANING

R 70 CP can be removed from tools and


equipment by using ARDEX ENDURA RTC 100
immediately after use. Any hardened material
will need to be removed mechanically.
PROPERTIES

The values shown are typical of results


obtained in the laboratory at 27 1C. Actual
performance values obtained on site may vary
from those quoted.
PHYSICAL PROPERTIES

R 70 CP

@ 27 1C

Mixed density

1.80 - 1.90g/cc

Pot life

15 - 20 mins

Light traffic

24 hours

Full traffic

48 hours

Full cure

7 days

Bond strength

> 1.5 N/mm

Compressive strength
DIN EN ISO 604

Min. 40 N/mm

Flexural strength
DIN EN ISO 178

18 N/mm

Tensile strength
DIN EN ISO 527

6.5 N/mm

Shore D Hardness

75

Abrasion resistance

Classified 'Special Duty'


under
BS 8204:Part 2:2002(9)

Slip resistance

Classified 'Satisfactory'
under
BS 8204: Part 2: 2002(9),
wet and dry

Impact resistance

Classified 'High Impact


Resistance' under
BS 8204: Part 1: 1999

COVERAGE ESTIMATES

Pack size

Coverage

16.50kg
Part A 2.32kg
Part B 2.94kg
Part C 10.84kg
Part D 400g

Approximately
4.0 m when
applied at a
thickness of 2mm

NOTE: These figures are theoretical, due to the wastages,


the variety and nature of substrates practical coverage
figures may be reduced.

STORAGE AND SHELF LIFE

R 70 CP has a shelf life of 6 months if kept in


a dry store between 5C and 30C in the
original unopened containers. The product
should be protected from frost, away from
direct sunlight and sources of heat.

CHEMICAL RESISTANCE

R 70 CP is resistant to a wide range of liquids


and chemicals, for specific information please
refer to the following ARDEX ENDURA
"Chemical Resistance" chart.
CHEMICAL RESISTANCE CHART SUMMARY OF RESULTS
Reagent

Concentration
in %

R 70 CP

10

100

Citric acid

50

Lactic acid

25

Methanol

100

Milk

100

Oleic acid

100

25

Acetic acid
Beer

Sulphuric acid

medical advice and after contact with the skin


wash immediately with plenty of soap and water
(do not use solvents). Prolonged contact with
the skin should be avoided, especially where the
user has an allergic reaction to resin-based
materials. Always wear gloves and eye/face
protection as necessary. Observe personal
hygiene, particularly washing the hands after
work has been completed or at any interruption
whilst work is in progress. Care should be taken
when removing gloves to avoid contaminating
the insides. In case of accidents seek medical
advice.
DISPOSAL/SPILLAGE

Spillage of any of the component products


should be absorbed onto sand or other inert
material and transferred to a suitable disposable
vessel. Disposal of such spillage or empty
packaging should be in accordance with local
waste disposal authority regulations.
For further information please refer to the
Material Safety Data Sheet.

Resistant

28 Days +

Limited Resistance

up to 7 Days

Not Resistant

Sold subject to the Company's conditions


of sale which are available on request.

Short Term Resistance

up to 1 Day

NOTE

These results are based on immersion


testing and ARDEX ENDURA products may
appear less resistant when compared with
other manufacturer's surface swab test results.
NOTE:

COLOURS

R 70 CP is available in six standard colours:


green, grey, orange, red, cream and yellow.
Other colours may be available to special
order, subject to quantity and technical
requirements.

CONDITIONS OF SALE

The information supplied in this datasheet is


based upon extensive experience and is given in
good faith in order to help you. Our Company
policy is one of continuous Research and
Development; we therefore reserve the right to
update this information at any time without prior
notice. We also guarantee the consistent high
quality of our products. However, as we have no
control over site conditions or the execution of
the work, we accept no liability for any loss or
damage which may arise as a result thereof.

ARDEX ENDURA polyurethane floor systems


are formulated to maximise the mechanical and
chemical resistance properties, as a result of
this, these types of systems are discoloured by
ultraviolet light leading to a yellowing effect.
This yellowing effect is dependent upon the
amount of UV exposure, both in terms of
intensity and time, and is more noticeable with
lighter colours.
PRECAUTIONS

05/15

During mixing and application the following


precautions should be observed: ensure
adequate ventilation and avoid contact of the
material with the eyes, nasal passages, mouth
and unprotected skin. Avoid contact with the
hands by wearing protective gloves and by
using, if necessary, a suitable barrier cream.
In case of contact with the eyes, rinse
immediately with plenty of water and seek

R 90 CP
Rake and Trowel Grade
Heavy Duty Polyurethane Screed
HIGH PERFORMANCE, POLYURETHANE RAKE AND TROWEL RESIN FLOORING SYSTEM,
SUPPLIED AS FOUR PARTS IN PRE-MEASURED PACKS FOR EASE OF ON SITE MIXING AND
USE. THE CURED SYSTEM FORMS A TOUGH, EASILY CLEANED, PIGMENTED LAYER FROM 4mm
UP TO 9mm THICK.

Features
Easily applied by rake and trowel
Hard wearing - extremely durable and abrasion resistant with
low maintenance cost
Facilitates rapid application
Resistant to a wide range of chemicals and liquids
Independently tested - suitable for use in food and
drinks production environments
Seamless - easily cleaned to maintain high standards of hygiene
Resistant to thermal shock - at 9 mm thick can withstand
steam cleaning regimes
STANDARD COLOURS
Available to any standard RAL Card upon request

ARDEX ENDURA (INDIA) PRIVATE LIMITED


Corporate Office & Regd. Office:
Unit No. 406 & 407, Brigade Rubix,
No. 20, HMT Campus, Yeshwanthapur Hobli,
Bengaluru - 560013. Karnataka, INDIA.
CIN No: U24233KA1997PTC022383
Tel: +91 80 66746500
Fax: +91 80 66746540
Email: customercare@ardexendura.com
Visit us: www.ardexendura.com

R 90 CP
Rake and Trowel Grade Heavy Duty Polyurethane Screed
HIGH PERFORMANCE, POLYURETHANE RAKE AND TROWEL RESIN FLOORING SYSTEM, SUPPLIED AS FOUR PARTS IN PRE-MEASURED PACKS FOR
EASE OF ON SITE MIXING AND USE. THE CURED SYSTEM FORMS A TOUGH, EASILY CLEANED, PIGMENTED LAYER FROM 4mm UP TO 9mm THICK.

DESCRIPTION

PRIMING

LIMITATIONS

Specialist applied, polyurethane resin floor


finish, combining outstanding wearing
properties with high chemical resistance
and decorative properties. Ideally suited to
aggressive areas where a seamless, joint free
finish is required and maximum cleanliness is
essential. Food processing and storage,
abattoir's, drinks production, dairies and
general heavy duty plant and traffic areas
are just some of the environments that can
benefit from this slip resistant system. R 90 CP
has been formulated to give an easily worked
system that can be applied quickly and easily
by using a pin rake, only requiring finishing with
a trowel to give the required finish.

All appropriate substrates to receive R 90 CP


must first be primed with ARDEX ENDURA R 3 E
Solvent Free Epoxy Primer. One or more coats
of primer may be required depending upon the
condition and porosity of the concrete
substrate. The final coat of ARDEX ENDURA
R 3 E Solvent Free Epoxy Primer must be
seeded with Fine Aggregate to provide a
mechanical key.
Alternatively priming can be achieved using a
nominal 1mm scratch coat of ARDEX ENDURA
R 70 CP. Mix the ARDEX ENDURA R 70 CP as
per the data sheet, pour onto the floor and
spread thinly using a straight edge trowel.
Scratch off the excess with the edge of the
trowel and leave to cure for 16 hours or
overnight.

R 90 CP should only be applied at


temperatures above 5C and where the
atmospheric relative humidity (RH) is 90% or
below. Floors should have an RH of 75% or
less. For floors with an RH of more than 75%,
the entire floor area should be treated with an
effective Suitable Damp Proof Membrane. The
substrate should have a surface tensile
strength of at least 1.5 N/mm.
R 90 CP and primer / Suitable Damp Proof
Membrane may be applied to substrates of a
lower strength, but long term performance may
be impaired. Once the mixed material has
exceeded its pot life, the viscosity and the
characteristics of the product will change and
any unused product should be discarded at this
time.

MIXING

CLEANING

The contents of Part A and Part B of R 90 CP


must first be mixed together for 1 minute, using
forced action, in a suitably sized mixing vessel.
The contents of Part C and Part D pigment
should then be introduced into the mixed resin
and mixed together for a further 2 minutes to
create one homogeneous mix. One or more
packs may be mixed at the same time in order
to maintain a quick rate of installation.

R 90 CP can be removed from tools and


equipment by using ARDEX ENDURA RTC 100
immediately after use. Any hardened material
will need to be removed mechanically.

SURFACE PREPARATION

The concrete or screed substrate must be


hard, sound and free of dust and other barrier
materials such as paint, lime coatings, plaster,
curing agents, polish, wax, grease, oil, laitance,
adhesive residues etc, that will inhibit adhesion
to the substrate.
Contaminated concrete surfaces should be
mechanically prepared, either by scabbling,
grinding or contained shot blasting equipment
or similar, and be vacuumed clean prior to
applying R 90 CP. Overwatered or otherwise
weak concrete surfaces must also be suitably
prepared down to sound, solid concrete by
mechanical methods. Dust and other debris
should be removed using vacuum equipment.
NOTE: Any joints or cracks in the concrete
base where differential movement is anticipated
e.g. movement joints, should be brought
through to the finished surface and suitably
sealed. New concrete slabs must be allowed
to cure for at least 14 days.
To ensure maximum bond, grooves must be
cut into the perimeter of the sub-floor, typically
8 mm deep by 8 mm wide. These should be
inset approximately 100mm from and running
parallel with the walls and adjacent to
doorways and plinths etc., including any
finishing edges and day joints. The grooves
must have clean, square edges and the
product laid into the full depth of the groove
forming a perimeter anchorage. Grooves
should surround areas not exceeding 20 m.
STEEL PLATES

Steel decking must be clean, sound and


properly supported to prevent flexing.
Deck plate of less than 4mm thick is not
recommended. Surfaces should be shot
blasted to SA2.5 and primed using
ARDEX ENDURA R 3 E Solvent Free Epoxy
Primer. If deck plates undergoes in
movement /flexing /vibration, installed R 90 CP
may crack or debond.

PROPERTIES

The values shown are typical of results


obtained in the laboratory at 27 1C. Actual
performance values obtained on site may vary
from those quoted.

APPLICATION

The mixed material should be applied to the


prepared and primed /scratch coat surface
without delay using a pin rake to achieve the
desired thickness and closed with a steel trowel.
If a smoother texture is required, as
soon as the product has been laid and as work
progresses, the surface should be gently rolled
with a short piled roller in order to provide an
even surface appearance. Do not over roll the
surface, as this will reduce the texture of the
surface finish. Do not re-roll later.
NOTE:

The work area should be protected during the


installation process and during the initial curing
time to ensure that no airborne debris can
contaminate the surface of the wet resin as this
will lead to unwanted blemishes in the hardened,
cured surface.
All movement joints in the sub-floor must be
carried through the topping and properly sealed.
Construction joints and cracks not subject to
movement may be overlaid but should the floor
move in anyway, these defects will reflect
through the system. Isolation joints will need
to be allowed for in areas where high thermal
movement is anticipated, e.g. around ovens
and freezers.

PHYSICAL PROPERTIES

R 90 CP

@ 27 1C

Pot life

15 - 20 mins

Mixed density

2.0 - 2.10 g/cc

Light traffic

24 hours

Full traffic

48hrs

Full cure

7 days

Bond strength

> 1.5 N/mm

Compressive strength
DIN EN ISO 604

Min. 45 N/mm

Flexural strength
DIN EN ISO 178

12 N/mm

Tensile strength
DIN EN ISO 527

6 N/mm

Shore D hardness

75

Abrasion resistance

Classified 'Special Duty'


under
BS 8204:Part 2:2002(9)

Slip resistance

Classified 'Satisfactory'
under
BS 8204: Part 2: 2002(9),
wet and dry

Impact resistance

Classified 'High Impact


Resistance' under
BS 8204: Part 1: 1999

Coverage

28.66kg

Approximately
2.50 m when applied
at a thickness of
5mm

Part A 2.32kg
Part B 2.94kg
Part C 23kg
Part D 400g

NOTE: These figures are theoretical, due to


the wastages and the variety and nature of
substrates practical coverage figures may be
reduced.

STORAGE AND SHELF LIFE

CHEMICAL RESISTANCE CHART SUMMARY OF RESULTS


Reagent

Concentration
in %

R 90 CP

10

Acetic acid
Beer

R
20

Lactic acid

25

Methanol

Milk

Oleic acid

R
25

R 90 CP has a shelf life of 6 months if kept in


a dry store between 5C and 30C in the
original unopened containers. The product
should be protected from frost, away from
direct sunlight and sources of heat.

Resistant

28 Days +

Limited Resistance

up to 7 Days

CHEMICAL RESISTANCE

Not Resistant

Short Term Resistance

R 90 CP is resistant to a wide range of liquids


and chemicals, for specific information please
refer to the following ARDEX ENDURA
"Chemical Resistance" chart.
COLOURS

R 90 CP is available in six standard colours:


green, grey, orange, red, cream and yellow.
Other colours may be available to special
order, subject to quantity and technical
requirements.
ARDEX ENDURA polyurethane floor systems are
formulated to maximise the mechanical and
chemical resistance properties, as a result of
this, these types of systems are discoloured by
ultraviolet light leading to a yellowing effect.
This yellowing effect is dependent upon the
amount of UV exposure, both in terms of
intensity and time, and is more noticeable with
lighter colours.

Sold subject to the Company's conditions


of sale which are available on request.
NOTE

Citric acid

Sulphuric acid

CONDITIONS OF SALE

The information supplied in this datasheet


is based upon extensive experience and is
given in good faith in order to help you.
Our Company policy is one of continuous
Research and Development; we therefore
reserve the right to update this information
at any time without prior notice. We also
guarantee the consistent high quality of our
products; however as we have no control over
site conditions or the execution of the work,
we accept no liability for any loss or damage
which may arise as a result thereof.

up to 1 Day

These results are based on immersion


testing and ARDEX ENDURA products may
appear less resistant when compared with other
manufacturer's surface swab test results.
NOTE:

PRECAUTIONS

During mixing and application the following


precautions should be observed: ensure
adequate ventilation and avoid contact of the
material with the eyes, nasal passages, mouth
and unprotected skin. Avoid contact with the
hands by wearing protective gloves and by
using, if necessary, a suitable barrier cream.
In case of contact with the eyes, rinse
immediately with plenty of water and seek
medical advice and after contact with the skin
wash immediately with plenty of soap and water
(do not use solvents). Prolonged contact with
the skin should be avoided, especially where the
user has an allergic reaction to resin-based
materials. Always wear gloves and eye/face
protection as necessary. Observe personal
hygiene, particularly washing the hands after
work has been completed or at any interruption
whilst work is in progress. Care should be taken
when removing gloves to avoid contaminating
the insides. In case of accidents seek medical
advice.
DISPOSAL/SPILLAGE

Spillage of any of the component products


should be absorbed onto sand or other inert
material and transferred to a suitable disposable
vessel. Disposal of such spillage or empty
packaging should be in accordance with local
waste disposal authority regulations.
For further information please refer to the
Material Safety Data Sheet.

05/15

COVERAGE ESTIMATES

Pack size

R 100 CE

Heavy Duty Epoxy Floor Screed

Features
High performance, epoxy floor screed system
Hard wearing, durable with low maintenance cost
Resistance to wide range of chemicals
Excellent slip resistance to foot traffic
Good abrasion resistance
Easily cleaned to maintain high standard of hygiene

STANDARD COLOURS
Available to any standard RAL Card upon request

ARDEX ENDURA (INDIA) PRIVATE LIMITED


Corporate Office & Regd. Office:
Unit No. 406 & 407, Brigade Rubix,
No. 20, Yeshwanthapur Hobli, HMT Campus,
Bangalore - 560022. Karnataka, INDIA.
CIN No: U24233KA1997PTC022383
Tel: +91 80 66746500
Fax: +91 80 66746540
Email: customercare@ardexendura.com
Visit us: www.ardexendura.com

R 100 CE
Heavy Duty Epoxy Floor Screed
DESCRIPTION

A specialist applied, epoxy screed floor finish


combining outstanding wearing properties with
chemical resistance. Ideally suited in areas
where maximum cleanliness is essential. Clean
rooms, heavy machinery industry, chemical
industries and general light industry are just
some of the environments that can benefit
from this system.
SUBSTRATE PREPARATION

The concrete or sand /cement screed


substrate must be hard, sound and free of
dust and other barrier materials such as paint,
lime coatings, plaster, curing agents, laitance,
adhesive residues polish, wax, grease, oil etc.,
that will inhibit adhesion to the substrate.
Use a suitable Degreaser to remove polish,
wax, grease, oil and similar contaminating
substances prior to mechanical preparation.
Contaminated concrete surfaces should be
mechanically prepared, either by scrabbling,
grinding or contained shot blasting equipment
or similar, and be vacuumed clean prior to
applying R 100 CE. Overwatered or otherwise
weak concrete surfaces must also be suitably
prepared down to sound, solid concrete by
mechanical methods. Dust and other debris
should be removed using vacuum equipment.
NOTE: Any joints or cracks in the concrete
base where differential movement is anticipated
e.g. movement joints, should be brought
through to the finished surface and suitably
sealed. New concrete slabs must be allowed
to cure for at least 28 days.
PRIMING

All appropriate substrates to receive R 100 CE


must first be primed with ARDEX ENDURA
R 3 CE Moisture Insensitive Primer. Two or
more coats of primer may be required
depending upon the condition and porosity
of the concrete substrate. Ensure that the
Primer is tacky prior to commencing
application of R 100 CE.

desired thickness. As soon as the product has


been laid and as work progress, the work area
should be protected during the installation
process and during the initial curing time to
ensure that no airborne debris can contaminate
the surface of the wet resin as this will lead to
unwanted blemishes in the hardened, cured
surface.
All movement joints in the sub-floor must be
carried through the topping and properly
sealed. Construction joints and cracks not
subject to movement may be overlaid but
should the floor move in any way, these defects
will reflect through the system. Isolation joints
will need to be allowed for in areas where high
thermal movement is anticipated, e.g. around
ovens and freezers.

The individual contents of the R 100 CE should


be thoroughly stirred before being mixed
together.
The entire contents of the Part A and Part B
should be poured in to a larger mixing vessel
to incorporate the Part C. Mix thoroughly with
a suitable mixing paddle. Finally the Part C is
added to the same container. The mixing of all
the three should continue until a consistent mix
is achieved. One or more packs may be mixed
simultaneously to ensure a quick rate of
installation subject to work force & site
clearance.
APPLICATION

For flooring application, the mixed material


should be applied to the prepared and primed
tacky surface, using a flat trowel to achieve the

> 17 N/mm

Abrasion resistance
ASTM C501

0.45g/1000 cycles

Application thickness

3 - 10 mm

CHEMICAL RESISTANCE

R 100 CE is resistant to a wide range of liquids


and chemicals, for specific information please
refer to the following ARDEX ENDURA
"Chemical Resistance" chart.
CHEMICAL RESISTANCE CHART SUMMARY OF RESULTS
Reagent

Concentration
in %

R 100 CE

Acetic acid

10

Acetic acid

50

Acetone

100

Ammonia

10

Ammonia

35

100

Citric acid

50

Formic acid

50

Hydrochloric
acid

25

Hydrogen
Peroxide

20vol

Kerosine

100

Lactic acid

25

Methylated
Spirit

100

Milk

100

Nitric acid

30

Nitric acid

70

Oleic acid

100

The values shown are typical of results


obtained in the laboratory at 27 1C. Actual
performance values obtained on site may vary
from those quoted.

Orange Juice

100

Petrol

100

10

PHYSICAL PROPERTIES

Red Wine

LIMITATIONS

R 100 CE should not be applied to floors that


are known to have rising moisture or have
relative humidity of greater than 75% at the time
of application. These products should not be
applied in temperatures less than 10C or
where the ambient relative humidity is greater
than 85%. Once the mixed material has
exceeded its pot life, the viscosity and the
characteristics of the product will change and
any unused product should be discarded at
this time.
Do not steam, clean or use hot water above
500C to wash the surface.
NOTE: All ARDEX ENDURA products are
manufactured under strict Quality Assurance
procedures; however it is recommended that
where colour consistency is essential, wherever
possible, products from one batch should be
used.
CLEANING

R 100 CE can be removed from tools and


equipment by using ARDEX ENDURA RTC 100
immediately after use. Any hardened material
will need to be removed mechanically.
PROPERTIES

MIXING

Tensile strength
BS 6319, Pt 7

R 100 CE

@ 27 1C

Beer

Phosphoric
acid

100

Saturated

Sodium
hydroxide

50

15

Saturated

Sulphuric acid

10

Sulphuric acid

25

Sulphuric acid

75

100

Salt

Pot life

45 mins

Mixed Density

2.20 - 2.25 g/cc

Foot traffic

24 hours

Full cure

7 days

Sodium
hyperchlorite

Bond strength

> 3 N/mm

Sugar

Compressive strength
ASTM C-109

> 90 N/mm

Flexural strength
BS 6319, Pt 3

> 30 N/mm

Xylene

Resistant

Limited Resistance

Not Resistant

Short Term Resistance

28 Days +
up to 7 Days

up to 1 Day

Note: These results are based on immersion


testing and ARDEX ENDURA products may
appear less resistant when compared with
other manufacturer's surface swab test results.
COVERAGE ESTIMATES

Pack size

Coverage

16.50 kg

Approx. 1.70m @

DISPOSAL/SPILLAGE

Spillage of any of the component products


should be absorbed onto sand or other inert
materials and transferred to a suitable
disposable vessel. Disposal of such spillage
or empty packaging should be in accordance
with local waste disposal authority regulations.
For further information please refer to the
Product Safety Data Sheet.
CONDITIONS OF SALE

Sold subject to the Company's conditions


of sale which are available on request.
NOTE

Part A : 1.3kg
5mm thick
Part B : 500g
Part C : 14.70kg
NOTE: These figures are theoretical, due to
wastage and the variety and nature of
substrates practical coverage rates may be
reduced.
STORAGE AND SHELF LIFE

R 100 CE has a shelf life of 12 months if kept


in dry condition between 5C and 30C in the
original unopened containers. The product
should be protected from frost, away from
direct sunlight and sources of heat.

The information supplied in this datasheet is


based upon extensive experience and is given in
good faith in order to help you. Our Company
policy is one of continuous Research and
Development; we therefore reserve the right to
update this information at any time without prior
notice. We also guarantee the consistent high
quality of our products; however as we have no
control over site conditions or the execution of
the work, we accept no liability for any loss or
damage which may arise as a result thereof.

COLOURS

R 100 CE is available to any standard RAL


Card upon request.
Epoxy flooring system are formulated to
maximise the mechanical and chemical
resistance properties.
PRECAUTIONS

06/15

During mixing and application the following


precautions should be observed: ensure
adequate ventilation and avoid contact of the
material with the eyes, nasal passages, mouth
and unprotected skin. Avoid contact with the
hands by wearing protective gloves and by
using, if necessary, a suitable barrier cream.
In case of contact with the eyes, rinse
immediately with plenty of water and seek
medical advice and after contact with the
skin wash immediately with plenty of soap and
water (do not use solvents). Prolonged contact
with the skin should be avoided, especially
where the user has an allergic reaction to
resin-based materials. Always wear gloves and
eye / face protection as necessary. Observe
personal hygiene, particularly washing the
hands after work has been completed or at any
interruption whilst work is in progress. Care
should be taken when removing gloves to avoid
contaminating the insides. In case of accidents
seek medical advice.

Anda mungkin juga menyukai