distribution boards
Protect
circuit protection
Tripping curves
C curve
Power circuit:
voltage rating (Ue): 440 V AC
breaking capacity:
- according to IEC 60898, Icn ultimate breaking capacity (O-CO cycle):
Rating (A)
6...63
Type
1P
2P, 3P
Voltage (V)
230/400
400
Fast closing: allows the high inrush currents of some loads to be better held.
Isolation with positive break indication: opening is indicated by a green strip on the
device operating handle. This indicator shows opening contacts of all the poles.
Number of cycles (O-C): 20,000.
Environment:
tropicalization: treatment 2 (relative humidity: 95% at 55C) according to
IEC 60068-1
Connection: tunnel terminals for the following cables:
16mm 2 exible or 25mm 2 rigid up to 25 A ratings
25mm 2 exible or 35mm 2 rigid for 32 to 63 A ratings
Catalogue numbers
Type
1P
2P
3P
Rating (A)
Width in mod.
of 9mm
Catalogue number
C curve
6
10
16
20
25
32
40
50
63
2
2
2
2
2
2
2
2
2
DOM11340
DOM11341
DOM11342
DOM11343
DOM11344
DOM11345
DOM11346
DOM11335
DOM11336
6
10
16
20
25
32
40
50
63
4
4
4
4
4
4
4
4
4
DOM11230
DOM11231
DOM11232
DOM11233
DOM11234
DOM11235
DOM11236
DOM11237
DOM11238
6
10
16
20
25
32
40
50
63
6
6
6
6
6
6
6
6
6
DOM11347
DOM11348
DOM11349
DOM11350
DOM11351
DOM11352
DOM11353
DOM11337
DOM11338
Protect
circuit protection
Tripping curves
B curve
Power circuit:
ratings: 6 to 63 A set at 30C
tripping curve: the magnetic trip units operate between 3 and 5 In
C curve
Power circuit:
voltage rating (Ue): 440 V AC
breaking capacity:
- according to IEC 60898, Icn ultimate breaking capacity (O-CO cycle):
Rating (A)
6...63
Type
1P
2P, 3P
Voltage (V)
230/400
400
Fast closing: allows the high inrush currents of some loads to be better held.
Isolation with positive break indication: opening is indicated by a green strip on the
device operating handle. This indicator shows opening contacts of all the poles.
Number of cycles (O-C): 20,000.
Environment:
tropicalization: treatment 2 (relative humidity: 95% at 55C) according to
IEC 60068-1
Connection: tunnel terminals for the following cables:
16mm 2 exible or 25mm 2 rigid up to 25 A ratings
25mm 2 exible or 35mm 2 rigid for 32 to 63 A ratings
Catalogue numbers
Type
1P
2P
3P
Rating (A)
Width in mod.
of 9mm
Catalogue number
B curve
C curve
6
10
16
20
25
32
40
50
63
2
2
2
2
2
2
2
2
2
DOM11362
DOM11363
DOM11364
DOM11365
DOM11366
DOM11367
DOM11414
DOM11607
DOM11608
DOM11375
DOM11376
DOM11377
DOM11378
DOM11379
DOM11380
DOM11381
DOM11598
DOM11599
6
10
16
20
25
32
40
50
63
4
4
4
4
4
4
4
4
4
DOM11417
DOM11418
DOM11419
DOM11420
DOM11421
DOM11368
DOM11369
DOM11609
DOM17321
DOM11384
DOM11385
DOM11386
DOM11387
DOM11388
DOM11389
DOM11390
DOM11600
DOM11601
6
10
16
20
25
32
40
50
63
6
6
6
6
6
6
6
6
6
DOM11426
DOM11427
DOM11428
DOM11429
DOM11430
DOM11431
DOM11432
DOM11610
DOM11611
DOM11393
DOM11394
DOM11395
DOM11396
DOM11397
DOM11398
DOM11399
DOM11602
DOM11603
Protect
earth leakage protection
AC class
Tripping is ensured for sinusoidal, alternating currents, whether they be quickly
applied or slowly increase.
Technical data
Voltage rating:
- 240...415 V AC
Frequency rating;
- AC class : 50 Hz
Catalogue numbers
AC class Residual Current Circuit Breaker (RCCB)
Type
Voltage
Rating
Sensitivity
50 Hz
(A)
(mA)
(V)
2P
240V
40
30
100
300
63
30
100
300
4P
415V
40
30
100
300
63
30
100
300
Catalogue
number
DOM16793
DOM16818
DOM16795
DOM16791
DOM16819
DOM16798
DOM11029
DOM16814
DOM11030
DOM16794
DOM16815
DOM16796
Protection
Circuit protection
(curve C)
DB116619
IEC/EN 60947-2
IEC/EN 60898-1
b iC60H circuit breakers are multi-standard circuit breakers which combine the
following functions:
v circuit protection against short-circuit currents,
v circuit protection against overload currents,
v suitable for industrial isolation according to IEC/EN 60947-2, standard.
v fault tripping indication by a red mechanical indicator in circuit breaker front face.
PB104451-40
PB104441-40
Service
breaking
capacity
(Ics)
Voltage (Ue)
Ph/Ph (2P, 3P, 4P)
12 to 133 V
12 to 60 V
70 kA
70 kA
70 kA
50 kA
100% of Icu
42 kA
30 kA
15 kA
10 kA
50% of Icu
400 V
Ph/N
230 V
Service
breaking
capacity
(Ics)
Voltage (Ue)
Between +/-
12 to 60 V y 72 V
y 125 V
y 180 V
y 250 V
Number of poles
1P
2P
3P
4P
15 kA
15 kA
15 kA
Rating (In) 1 to 63 A 20 kA
15 kA
100% of Icu
Catalogue numbers
iC60H circuit breaker
Type
1P
1P+N
2P
3P
4P
__________________________________________________________________________________________________________________________________________________________________________
Rating (In)
Curve C
Curve C
Curve C
Curve C
Curve C
__________________________________________________________________________________________________________________________________________________________________________
6
A
A9F84106
A9F84606
A9F84206
A9F84306
A9F84406
__________________________________________________________________________________________________________________________________________________________________________
10 A
A9F84110
A9F84610
A9F84210
A9F84310
A9F84410
__________________________________________________________________________________________________________________________________________________________________________
13
A
A9F84113
A9F84613
A9F84213
A9F84313
A9F84413
__________________________________________________________________________________________________________________________________________________________________________
16 A
A9F84116
A9F84616
A9F84216
A9F84316
A9F84416
__________________________________________________________________________________________________________________________________________________________________________
20
A
A9F84120
A9F84620
A9F84220
A9F84320
A9F84420
__________________________________________________________________________________________________________________________________________________________________________
25 A
A9F84125
A9F84625
A9F84225
A9F84325
A9F84425
__________________________________________________________________________________________________________________________________________________________________________
32
A
A9F84132
A9F84632
A9F84232
A9F84332
A9F84432
__________________________________________________________________________________________________________________________________________________________________________
40A
A9F84140
A9F84640
A9F84240
A9F84340
A9F84440
__________________________________________________________________________________________________________________________________________________________________________
50A
A9F84150
A9F84650
A9F84250
A9F84350
A9F84450
__________________________________________________________________________________________________________________________________________________________________________
63A
A9F84163
A9F84663
A9F84263
A9F84363
A9F84463
__________________________________________________________________________________________________________________________________________________________________________
Width in 9-mm modules
2
4
4
6
8
__________________________________________________________________________________________________________________________________________________________________________
PB104435-40
Protection
Circuit protection
Visi-trip window
b Large circuit
labelling area
Protection
Load protection
The iPF surge arresters with r indication have remote transfer of the information:
surge arrester to be replaced.
DB122943
Rated discharge
current (Imax) /
Nominal discharge
current (In)
2P
3P
4P
PB105278-35
65 kA / 20 kA
A9L15683
iPF65
A9L15684
A9L15584
A9L15581
A9L15685
A9L15586
A9L15585
40 kA / 15 kA
High risk level
A9L15686
iPF40
A9L15687
1P+N.
A9L15587
PB105280-35
A9L15690
A9L15688
A9L15582
A9L15590
A9L15588
20 kA / 5 kA
Medium risk level
A9L15691
iPF20
A9L15692
A9L15592
A9L15693
A9L15597
A9L15593
8 kA / 2.5 kA
3P+N.
Secondary protection:
placed near the loads to be
protected when they are at a
distance of more than 30m
from the incoming surge
arrester
A9L15694
iPF8
A9L15695
A9L15595
A9L15696
A9L15598
A9L15596
Protection
Load protection
Earthing
system
Transfer Surge
arrester
name
Width
in mod.
of 9mm
Up - (kV)
Voltage protection level
CM*
DM*
L/t
N/t
L/N
2
4
y 1.5
-
y 1.5
y 1.5
y 1.5
y 1.5
y 1.5
y 1.5
y 1.5
y 1.5
y 1.5
2
4
y 1.5
y 1.5
y 1.5
y 1.5
y 1.5
y 1.1
y 1.1
y 1.1
y 1.1
Un - (V)
Rated
voltage
network
Uc - (V)
Maximum continuous
operating voltage
CM*
DM*
L/t
N/t
L/N
230
340
-
260
340
340
340
y 1.5
y 1.5
-
230/400
340
340
260
260
340
340
340
-
y 1.5
y 1.5
y 1.5
y 1.5
y 1.5
y 1.5
y 1.5
y 1.5
y 1.5
-
230
340
340
340
340
340
260
340
260
260
340
340
340
340
340
-
y 1.5
y 1.1
y 1.5
y 1.1
y 1.1
y 1.1
-
230
340
340
340
340
260
340
260
340
340
340
-
TT & TN
iPF8 1P
2
y 1 / y 1.1
230
340
TT & TN-S
iPF8 1P+N
4
y 1.5 / y 1.2 y 1 / y 1.1
260
TN-C
iPF8 2P
y 1 / y 1.1
y 1 / y 1.1
340
340
TN-C
iPF8 3P
8
y 1 / y 1.1
230/400
340
TT & TN-S
iPF8 3P+N
y 1.5 / y 1.2 y 1 / y 1.1
260
TN-C
iPF8 4P
y 1 / y 1.1
y 1 / y 1.1
340
340
* CM: common mode (phase to earth and neutral to earth). * DM: differential mode (phase to neutral). (1) Uoc: combination waveform : 10 kV.
340
340
-
iPF65
TT & TN
TT & TN-S
iPF65 1P
iPF65 1P+N
TN-C
iPF65 2P
TN-C
TT & TN-S
TT & TN-S
TN-C
iPF65 3P
iPF65r 3P+N
iPF65 3P+N
iPF65r 4P
b
b
iPF40
TT & TN
TT & TN-S
TN-C
TN-C
TT & TN-S
TT & TN-S
TN-C
TN-C
b
b
iPF40 1P
iPF40 1P+N
iPF40 2P
iPF40 3P
iPF40r 3P+N
iPF40 3P+N
iPF40r 4P
iPF40 4P
230/400
iPF20
TT & TN
TT & TN-S
TN-C
TN-C
TT & TN-S
TN-C
iPF20 1P
iPF20 1P+N
iPF20 2P
iPF20 3P
iPF20 3P+N
iPF20 4P
iPF8 (1)
2
4
8
230/400
Type 2 / Type 3
r1 = 1P + N : Full Mode
r2 = 3P + N : Full Mode
Protection
Load protection
Type of
protection
Network
DB122943
Rated discharge
current (Imax) /
Nominal discharge
current (In)
DB122942
iPRD withdrawable
surge arresters allow
quick replacement of
damaged cartridges.
r1 3P+N r2 1P
2P
3P
4P
PB105274-35
65 kA / 20 kA
Very high risk level
(strongly exposed site)
A9L16555
iPRD65
A9L16556
A9L16557
A9L16442
A9L16558
A9L16443
A9L16559
1P+N
A9L16659
40 kA / 15 kA
High risk level
A9L16561
A9L16566
iPRD40
A9L16562
A9L16567
PB105275-35
A9L16444
A9L16667
A9L16564
A9L16569
A9L16445
A9L16568
A9L16563
A9L16597
A9L16664
A9L16669
20 kA / 5 kA
Medium risk level
3P
A9L16571
iPRD20
A9L16672
A9L16572
A9L16446
PB105276-35
A9L16674
A9L16574
A9L16447
A9L16573
A9L16599
A9L16673
8 kA / 2.5 kA
Secondary protection:
placed near the loads to be
protected when they are at a
distance of more than 30m
from the incoming surge
arrester
A9L16677
A9L16577
PB105272-35
Spare cartridges
Type
A9L16448
A9L16679
A9L16579
3P+N
Cartridge
A9L16576
iPRD8
C 65-460
C 65-340
C 40-460
C 40-340
C 20-460
C 20-340
C 8-460
C 8-340
C neutral
A9L16449
A9L16578
A9L16678
A9L16680
Cat. no
iPRD65r IT
iPRD65r
iPRD40r IT
iPRD40, iPRD40r
iPRD20r IT
iPRD20, iPRD20r
iPRD8r IT
iPRD8, iPRD8r
All products
A9L16682
A9L16681
A9L16684
A9L16685
A9L16686
A9L16687
A9L16688
A9L16689
A9L16691
Protection
Load protection
Earthing
system
Transfer Surge
arrester
name
Width
in mod.
of 9mm
Up - (kV)
Voltage protection level
CM*
DM*
L/t
N/t
L/N
y2
y 1.5
-
y 1.5
y 1.5
Un - (V)
Rated
voltage
network
Uc - (V)
Maximum continuous
operating voltage
CM*
DM*
L/t
N/t
L/N
460
340
-
260
340
iPRD65
IT
iPRD65r 1P IT
TT & TN
TT & TN-S
b
b
iPRD65r 1P
iPRD65r 1P+N
TN-C
iPRD65r 2P
IT
TN-C
TT & TN-S
TN-C
b
b
b
b
iPRD65r 3P IT
iPRD65r 3P
iPRD65r 3P+N
iPRD65r 4P
TT & TN
TT & TN
TT & TN-S
TT & TN-S
TN-C
TN-C
TN-C
TN-C
IT
TT & TN-S
TT & TN-S
IT
TN-C
TN-C
230
y 1.5
y 1.5
340
340
y2
y 1.5
y 1.5
y 1.5
y 1.5
y 1.5
-
230/400
460
340
340
260
340
340
-
y 1.4
y 1.4
y 1.4
y 1.4
y 1.4
y 1.4
y2
y2
y 1.4
y 1.4
y 1.4
y 1.4
y 1.4
y 1.4
y 1.4
y 1.4
y2
y 1.4
y 1.4
y 1.4
y 1.4
y 1.4
y 1.4
-
230
340
340
340
340
340
340
460
460
340
340
260
260
340
340
260
260
460
340
340
340
340
340
340
-
y 1.1
y 1.1
y 1.1
y 1.6
y 1.6
y 1.1
y 1.4
y 1.4
y 1.1
y 1.4
y 1.4
y 1.6
y 1.1
y 1.1
y 1.1
y 1.1
y 1.1
-
230
340
340
340
460
460
340
260
260
340
260
260
460
340
340
340
340
340
-
TT & TN
iPRD8 1P
2
y1/y1
230
340
TT & TN-S
b
iPRD8r 1P+N
4
y 1.4 / y 1
y 1 / y 1.1
260
TT & TN-S
iPRD8 1P+N
y 1.4 / y 1
y 1 / y 1.1
260
TN-C
iPRD8 2P
y1/y1
y1/y1
340
340
TN-C
iPRD8 3P
6
y1/y1
230/400
340
IT
b
iPRD8r 3P IT
y 1.4 / y 1.6 460
TT & TN-S
b
iPRD8r 3P+N
8
y 1.4 / y 1
y 1 / y 1.1
260
TT & TN-S
iPRD8 3P+N
y 1.4 / y 1
y 1 / y 1.1
260
IT
b
iPRD8r 4P IT
y 1.4 / y 1.6 y 1.4 / y 1.6 460
460
TN-C
iPRD8 4P
y1/y1
y1/y1
340
340
* CM: common mode (phase to earth and neutral to earth). * DM: differential mode (phase to neutral). (1) Uoc: combination waveform : 10 kV.
340
340
340
340
-
6
8
iPRD40
b
b
b
b
b
b
b
iPRD40r 1P
iPRD40 1P
iPRD40r 1P+N
iPRD40 1P+N
iPRD40r 2P
iPRD40 2P
iPRD40r 3P
iPRD40 3P
iPRD40r 3P IT
iPRD40r 3P+N
iPRD40 3P+N
iPRD40r 4P IT
iPRD40r 4P
iPRD40 4P
2
4
230/400
iPRD20
TT & TN
TT & TN-S
TT & TN-S
TN-C
TN-C
IT
TT & TN-S
TT & TN-S
IT
TN-C
b
b
b
iPRD20 1P
iPRD20r 1P+N
iPRD20 1P+N
iPRD20 2P
iPRD20 3P
iPRD20r 3P IT
iPRD20r 3P+N
iPRD20 3P+N
iPRD20r 4P IT
iPRD20 4P
iPRD8 (1)
2
4
6
8
230/400
Type 2 / Type 3
r1 = 1P + N : Full Mode
r2 = 3P + N : Full Mode
Functions
and characteristics
Selection table
CPB100600
EZC100-1P.
Fixed version
Plug-in version
Number of poles
Rated current (A)
In
Ui
Uimp
Ue
at 40C
AC 50/60 Hz
DC
Ics
CPB100601
CPB100602
EZC100-2P.
AC 50/60 Hz 110/130 V
220/230/240 V
380 V
400/415 V
440 V
550 V
DC
125 V (1P)
250 V
(2P in series)
% Icu
110-400 V
415-550 V
Mechanical
Electrical
In/415 V
HIC
AC 50/60 Hz 240 V
277/480 V
Protection
Overload protection
Instantaneous protection
Bimetal
Magnetic
Fixed (20 %)
Auxiliary switch
Alarm switch
Combined AX + AL
Shunt trip release
Undervoltage release
AX
AL
AXAL
SHT
UVR
Auxiliaries
Indication contacts
EZC100-3P.
Voltage releases
CPB100603
Installation
Connection
Accessories
Crimp lugs/bars
Box lugs for bare cables
Rotary handles
Terminal extensions
Spreaders
Phase barriers
Terminal shields
Padlocking system
DIN rail adaptor
EZC100-4P.
Dimensions (mm)
Weight (kg)
EZC250-3P.
10
DxH
W
Direct
Extended
EZC100B
EZC100F
EZC100N
EZC250F
EZC250N
EZC100H
(4)
3-4
15, 16, 20, 25,
30, 32, 40, 45,
50, 60, 63, 75,
80, 100
690
6
550
250
2-3-4
15, 16, 20, 25,
30, 32, 40, 45,
50, 60, 63, 75,
80, 100
690
6
550
250
3
100, 125, 150,
160, 175, 200,
225, 250
3
100, 125, 150,
160, 175, 200,
225, 250
2-3
100, 125, 150,
160, 175, 200,
225, 250
690
6
550
-
3
15, 16, 20, 25,
30, 32, 40, 45,
50, 60, 63, 75,
80, 100
690
6
550
250
1
15, 16, 20, 25,
30, 32, 40, 45,
50, 60, 63, 75,
80, 100
690
6
415
125
(4)
3
15, 16, 20, 25,
30, 32, 40, 45,
50, 60
1
15, 16, 20, 25,
30, 32, 40, 45,
50, 60, 63, 75,
80, 100
690
6
415
125
690
6
550
250
690
6
550
250
690
6
550
250
10
10
7.5
7.5
5
2.5
-
25
25
10
10
7.5
5
5
5
25
18
2.5
2.5
5
-
25
25
18
15
10
5
5
5
50
25
5
5
10
-
100
100 (1)
30
30
20
10
10
10
25
25
18
18
15
5
5
5
50
50
25
25
20
8
20
20
25 %
25 %
50 %
50 %
50 %
50 %
50 %
50 %
50 %
50 %
50 %
25 %
50 %
50 %
50 %
50 %
50 %
50 %
A
3
8 500
1 500
A
3
8 500
1 500
A
3
8 500
1 500
A
3
8 500
1 500
A
3
8 500
1 500
A
3
8 500
1 500
A
3
10 000
5 000
A
3
10 000
5 000
A
3
10 000
5 000
10
10 (2)
25
10
18
18 (2)
100
18 (3)
25
15
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
fixed
10 In
50
18
fixed
10 In
EZC250H
85
85
36
36
25
10
30
30
85
25 (3)
fixed
10 In
(3)
(3)
(3)
60 x 130
75
60 x 130
75
60 x 130
25
60 x 130
75 (3P)
100 (4P)
60 x 130
25
60 x 165
105
60 x 165
105
60 x 165
105
0.78
0.78
0.28
0.78 (3P)
1.0 (4P)
0.28
60 x 130
50 (2P)
75 (3P)
100 (4P)
0.6 (2P)
0.78 (3P)
1.0 (4P)
1.3
1.3
1.1 (2P)
1.3 (3P)
11
Mini Pragma
Presentation
PB104674-90
36-module enclosures
PB104091-25
PB104089-25
PB104102-47
18-module enclosures
4-module enclosures
Removable chassis
PB104631-90
Blanking plates
Options
12
Mini Pragma
Functions
and technical data
Function
Description
Offer to compose
This offer can compose the enclosures according to their own preference, based on
a choice of 5 colours of different front face and a large number of accessories.
OR
Offer composed
This offer allows having for a single reference a complete enclosure equipped with:
b a symmetrical back box
v robust
v depth adapted to the walls of reduced thickness
v with pre-holes for entry tubes on the 4 sides
b 1 to 3 rails DIN, chassis allows the cabling outside the back box
b a rigid and reversible white (RAL 9003) front face, fitted with pre-cutout blanking
plates with white opaque or translucent door or smoked transparent door
b an earth and neutral terminal block
PB104108-20
36-module
enclosures
24-module
enclosures
18-module
enclosures
12-module
enclosures
8-module
enclosures
PB104073-19
PB104071-40
PB104077-20
PB104079-22
PB104081-21
PB104083-29
PB104085-40
6-module
enclosures
4-module
enclosures
Technical data
Enclosures
PB104107-20
White door.
13
Functions
and technical data
Mini Pragma
PB104073-36
Cat. no.
Number of
rows
Number of
modules per
row
4
6
8
12
18
12
12
4
6
8
12
18
24
36
MIP20104T
2
3
50
63
63
63
63
63
63
MIP22104
MIP22106
MIP22108
MIP22112
MIP22118
MIP22212
MIP22312
With smoked
translucent
door
MIP22104T
MIP22106T
MIP12108T
MIP22112T
MIP22118T
MIP22212T
MIP22312T
14
2 x (1 x 16 v + 2 x 10 v + 1 x 6 v)
2 x (1 x 16 v + 4 x 10 v + 3 x 6 v)
2 x (2 x 16 v + 8 x 10 v + 6 x 6 v)
2 x (2 x 16 v + 9 x 10 v + 9 x 6 v)
Presentation
Mini Pragma
36-module enclosures
PB104058-30
PB104067-21
PB104071-40
18-module enclosures
4-module enclosures
PB104675-90
Insulating edge
DIN rails
Fixation
PB104632-90
Blanking plates
Options
15
Functions
and technical data
Mini Pragma
Function
Description
36-module
enclosures
24-module
enclosures
18-module
enclosures
12-module
enclosures
8-module
enclosures
PB104059-20
PB1040641-19
PB104063-20
PB104065-22
PB104067-21
PB104069-29
PB104071-40
6-module
enclosures
4-module
enclosures
PB104108-20
Technical data
Enclosures
PB104107-20
White door
16
Functions
and technical data
Mini Pragma
PB104059-35
Catalogue numbers
White enclosures
PB104650-30
MIP10104T
Cat. no.
Number of
rows
Number of
modules per
row
4
6
8
12
18
12
12
4
6
8
12
18
24
36
2
3
50
63
63
63
63
63
63
MIP12104
MIP12106
MIP12108
MIP12112
MIP12118
MIP12212
MIP12312
With smoked
translucent
door
MIP12104T
MIP12106T
MIP12108T
MIP12112T
MIP12118T
MIP12212T
MIP12312T
Insulating plug
Identification strip
for each row
Two terminal block supports
Two earth/neutral terminal
blocks
2 x (1 x 16 v + 2 x 10 v + 1 x 6 v)
2 x (1 x 16 v + 4 x 10 v + 3 x 6 v)
2 x (2 x 16 v + 8 x 10 v + 6 x 6 v)
2 x (2 x 16 v + 9 x 10 v + 9 x 6 v)
17
Accessories
Mini Pragma
Cat. no.
Description
Solid white
Blanking plate
13387
Marker light
MIP99050
PB104673-20
PB104125-20
Type
18
Control
Remote control
PB106256-40
PB106257-40
ARA iC60
Catalogue numbers
ARA iC60
For circuit breaker
1P, 1P+N, 2P
Width in 9mm
modules
Number of
programs
Voltage
3P, 4P
ARA iID
ARA iID
For residual current circuit breaker
DB124065
Diagram
2P
230 V
Voltage
Auxiliaries
Locked OF
Y1 Y2
N P
Legend
DB123582
Type
DB124061
DB124060
Number of
programs
4P
iC60 or iID
21 22 24 1112 14
ARA
DB406179
ARA iC60
DB123583
Width in 9mm
modules
Application
Y1
Y2
N
P
Locked
OF
11 12 14
Indicator
lamp
ARA iID
Flashing green
Flashing red
Fixed red
Flashing orange
19
Control
Remote control
Number of
reclosing
attempts
Delay
before
reclosing
Check time
TA
TB
Final
reclosing Y2
DB124064
DB124063
DB124062
DB124061
Program
60 s
6 min.
4
1
3
2
60 s
3 min.
3 min.
2 min.
6 min.
6 min.
60 s
3 min.
3 min.
3 min.
3 min.
60 s
3 min.
4 min.
5 min.
6 min.
2 min.
6 min.
6 min.
6 min.
6 min.
2 min.
6 min.
8 min.
10 min.
12 min.
Delay
before
reclosing
Check time
ARA iID
Number of
reclosing
attempts
Only 1 program 15
available
Once after
inhibition
TA
TB
20 s
40 s
3 min.
3 min.
...
30 min.
30 min.
...
Final
reclosing Y2
b Sealable cover
b Placing in safety configuration by
integrated padlocking device ( 3 to 6mm)
PB106055-104
b Indication of ARA
operating states
ARA iC60
b 4 predefined
programs
20
b Inhibition of automatic
recloser (auto - OFF) and
resetting (Reset)
iC60H RCBO
Protect
Circuit protection
10000 A
10, 30 and 100 mA
DB405571
IEC 61009-1,
IEC 61009-2-2,
BS EN 61009-1
AS/NZS 61009.1
PB111075-70
6 to 45 A
110 V
240 V
10000 A
10000 A
Accessory
Padlocking device
b Used to lock the toggle in the "open" position by 3mm diameter padlock (not
supplied).
Catalogue numbers
iC60H RCBO 10000
1P+N
B curve
A
Voltage rating (V)
DB405038
240
C curve
DB405038
110
240
Operating frequency
Sensitivity (In)
Rating
(In)
10 mA
30 mA
100 mA
6A
A9D31806
10 A
A9D31810
16 A
A9D31816
20 A
A9D31820
25 A
A9D31825
32 A
A9D31832
40 A
A9D31840
45 A
A9D31845
Sensitivity (In)
Rating
(In)
Rating
(In)
Width in 9mm
modules
10 mA
30 mA
100 mA
10 A
A9D19810
16 A
A9D19816
20 A
A9D19820
25 A
A9D19825
32 A
A9D19832
6A
A9D10806
A9D11806
A9D12806
10 A
A9D10810
A9D11810
A9D12810
16 A
A9D10816
A9D11816
A9D12816
20 A
A9D10820
A9D11820
A9D12820
25 A
A9D10825
A9D11825
A9D12825
32 A
A9D10832
A9D11832
A9D12832
40 A
A9D10840
A9D11840
A9D12840
45 A
A9D10845
A9D11845
A9D12845
5060 Hz
21
iC60 RCBO
Protect
Circuit protection
b Test push-button
PB111075-70
DB405553
Visi-trip window
DB405556
DB405582
DB406319
b Padlocking device
b Increased product service life thanks to fast closing independent of the speed of
actuation of the toggle.
b Remote indication, open/closed/tripped, by optional auxiliary contacts.
Connection
Tightening torque
6.5mm
PZ2
N in and L in
L out and N out
PZ2
13mm
22
5.5mm
Copper cables
Rigid
DB122945
14mm
Rating
6 to 45 A
3.5 N.m
2 N.m
Flexible
DB122946
DB405564
Type
1 to 25mm2
1 to 16mm2
1 to 16mm2
1 to 10mm2
Control
Remote control
DB123312
DB123310
DB123567
Dimensions (mm)
4P
3P
2P (1P+N)
1P
135
117
99
81
63
5.5
70
44.5
85
45
6
80
97
23
iC60 RCBO
Protect
Circuit protection
DB123311
DB123309
Dimensions (mm)
DB405565
72
45
18
72
19
45
36
19
20
5.5
20
5.5
45
110
55
55
15
iC60H RCBO
DB123312
(curve C)
DB123392
Dimensions (mm)
4P
69.5
54
1P+N / 2P
1P
78.5
72
3P
36
18
50
5.5
4.4
94 85
45
64
4.6
24
45
110
15
Protection
Load protection
DB123596
Dimensions (mm)
1P
1P+N
2P
3P
3P+N
4P
DB123595
Dimensions (mm)
1P
1P+N
2P
3P
3P+N
4P
25
Modular switchgear
Dimensions
Protect
Earth leakage switches
Domae RCCB mono-connect
4P
2P
187-0404
PF
PRD
26
190-0404
Mounting on plate
DB115255
DB115254
DB111976
DB111975
2P
DB115259
DB111977
1P
DB112000
DB111979
DB111974
DB111973
Dimensions
DB111981
DB111980
Dimensions
EasyPact 100
3P
4P
1P
2P
or
3P
4P
or
27
EasyPact 100
2P
4P
DB114582
DB111988
3P
28
4P
DB111987
1P
DB111986
DB111985
2P
DB111984
1P, 3P
DB111983
DB111982
DB114581
Dimensions
EasyPact 250
Dimensions
2P, 3P
4P
35
50
??
52.5
35
DB111949
DB111948
DB111947
Dimensions (EZC250)
144
102
19.5
25
22
100
105
Mounting on plate
4P
DB111954
DB111953
2P, 3P
44
29
EasyPact 250
2P, 3P
4P
DB111956
2P, 3P
4P
DB111959
DB111958
DB111960
DB111955
DB111957
Dimensions
Dimensions (mm)
EZC 2/3P
EZC 4P
30
A
60
68
B
65
73
C
85.5
95
D
-
E
67
75
F
61
69
Mini Pragma
Dimensions
DB122738
268
376
268
196
160
198
228
353
124
4, 6 modules
8, 12, 18 modules
267
24 modules
Side view
101.5
102
478
101.5
125
102
17
36 modules
23
125
126.5
23
8, 12, 18 modules
4, 6 modules
23
24 modules
36 modules
170
143
170
Inside view
143
165
93
6 modules
8 modules
12 modules
295
420
4 modules
170
DB122739
126.5
126.5
101.5
198
228
96.5
353
101.5
125
478
101.5
95
273
18 modules
165
24 modules
165
36 modules
31
Mini Pragma
Dimensions
DB123283
294
402
294
222
186
4, 6, 8, 12, 18 modules
377
102
252
102
150
24 modules
294
Side view
80
70
18
13
80
70
18
20
18
478
80
70
60.5
19.5
125
13
20
125
228
353
125
13
13
13
502
102
13
36 modules
4, 6, 8, 12, 18 modules
24 modules
36 modules
Top view
126
162
198
55
63
20
4 modules
20
20
6 modules
8 modules
378
57
44
20
18 modules
32
16
57
270
44
16
55
47
44
16
20
47
Nationwide Branches
Johor Bahru
Tel : (607) 351 3801 / 802
Fax : (607) 351 4113
Kota Kinabalu
Tel : (6088) 237 000 / 012
Fax : (6088) 216 900
Penang
Tel : (604) 643 8187 / 175
Fax : (604) 643 9197
Kuching
Tel : (6082) 450 242
Fax : (6082) 450 373
Find us on
www.facebook.com/SchneiderElectricMY
SEIMWD-DDB-14