Anda di halaman 1dari 4

Bulletin 5715-540

Installation Manual
EX-M03

Test Unit for


Proportional Valves with
Integrated Electronics

Parker Hannifin GmbH


Hydraulic Controls Division
Gutenbergstr. 38
41564 Kaarst, Germany
Tel.:
(+) 2131-513-0
Fax:
(+) 2131-513-230
www.parker.com
Copyright 2000, Parker Hannifin GmbH

Contents

Test Unit
Series EX-M03

Installation Manual

Note
This document and other information from Parker Hannifin GmbH, its
subsidiaries, sales offices and authorized distributors provide product or
system options for further investigation by users having technical
expertise. Before you select or use any product or system it is important
that you analyse all aspects of your application and review the information
concerning the product or system in the current product catalogue. Due
to the variety of operating conditions and applications for these products
or systems, the user, through his own analysis and testing, is solely
responsible for making the final selection of the products and systems
and assuring that all performance and safety requirements of the
application are met. The products are subject to change by Parker
Hannifin GmbH at any time without notice.

IA EX-M03 UK.PM6.5 RH 03.08.00

Home

Parker Hannifin GmbH


Hydraulic Controls Division

Test Unit
Series EX-M03

Installation Manual
The test unit EX00-M03 is usable for the control of
proportional valves incorporating integrated electronics. It provides commissioning and function
test independently from the machine control system. The test unit is provided with all necessary
signal and measurement taps, making it possible
to proceed initial operation and diagnosis.
Features

Control of valves incorporating integrated


electronics and central plug acc. DIN 43563
(6p.+PE)
Mains connection selectable 230/115VAC
Build-in fuses
Cordset included
Integrated digital voltmeter with test point selector switch
Test jacks
Rugged metal enclosure with handles

EMC
EN 50081-1
EN 50082-2

Characteristics
Design
Supply voltage
Power consumption
Current consumption max.
Mains input fuse
Valve output fuse
Required mains supply fuse
Protection class
Valve central connection
valve supply
command voltage
diagnostic output
enable signal
Measurement terminals
Display
display digits
resolution
Mains cord
unit site
mains site
cord length
Valve cord
unit site
valve site
cord length
Ambient temperature
Weight
Dimensions

[V]
[VA]
[A]
[A]
[A]
[A]

[V]
[V]
[V]
[V]

[mV]

[m]

[m]
[C]
[kg]
[mm]

Aluminium die cast enclosure


115/230, 50...60Hz
max. 80
0.7 / 0.35
2 time lag
3 time lag
16
IP40
24 (20%)
0...10 (1%)
0...10
7.5 (10%)
for multimeter with Ri min = 10kOhm
3
100
Cold inlet connector IEC320
CEE 7/7 plug
2
cable mount inlet DIN 40 040 Amphenol SV70
cable mount outlet DIN 43 563
3
0...40
3.2
L 220 x B 120 x H 90 (without handles)

IA EX-M03 UK.PM6.5 RH 03.08.00

Home

Parker Hannifin GmbH


Hydraulic Controls Division

Test Unit
Series EX-M03

Installation Manual
Ordering Code

EX

M03

00

Test Unit

Series

Operator Panel
Front Side

Rear Side

Switch over of voltage selector

Remove voltage selector housing from its socket by using a screwdriver


Pull the light coloured connection unit including fuse off the selector housing.
Turn the connection unit by 180 and press back inside.
Press the voltage selector housing back inside its socket, until it is locked.
The selected mains voltage is visible within the display section of the voltage selector. Please note,
that the selected voltage must be equal to the mains voltage.

Otherwise the unit will be damaged!


Wiring Configuration

IA EX-M03 UK.PM6.5 RH 03.08.00