Anda di halaman 1dari 2

Transmittal Report:

Created by AutoCAD eTransmit Tuesday, November 24, 2015, 4:53 PM.


Drawing:
This is a transmittal based on multiple drawings.
Files:
Root Drawings:
DC-TEI-PH3-TD-352_A.dwg
DC-TEI-PH3-TD-704_0.dwg
DC-TEI-PH3-TD-355_A.dwg
DC-TEI-PH3-TD-356_A.dwg
DC-TEI-PH3-TD-359_A.dwg
DC-TEI-PH3-TD-370_0.dwg
DC-TEI-PH3-TD-371_A.dwg
DC-TEI-PH3-TD-703_0.dwg
AutoCAD Drawing (External) References:
xref\TITLE - A1.dwg
xref\Al Taween Base_A.dwg
xref\Xref_126-3_Chainage-7 Km Extension of Emirates Road.DWG
xref\Xref_126-3_V01_7km_Road Layout.dwg
xref\Xref_126-III_LAYOUT.dwg
Xref\140109_As Built_Hospital Rd_Phase-1_MPW.dwg
xref\BASE 13_Tie in Phase 1_P2_F_11-03-15_A.dwg
Submission Taween Road Phase 3, Additional Survey\Existing Farm fence_c
heck.dwg
xref\150824_Plan of Chainages_Emirates road Cloverleaf IC_scale 3000.dwg
xref\BASE - Phase 3_up check_op 3.dwg
UTILITIES EXISTING\RAK-EX-UTICO.dwg
xref\150824_Plan of Chainages_Emirates road Cloverleaf IC_scale 1000.dwg
xref\TITLE - A1-For Plan & Profile.dwg
xref\150908_Plan of Earthworks_Emirates Road Cloveraf IC (E611)_MX.dwg
UTILITIES EXISTING\RAK-Prop-DU Corridor.dwg
UTILITIES EXISTING\RAK-EX-du_mobile towers.dwg
UTILITIES EXISTING\RAK-EX-EMARAT GAS.dwg
UTILITIES EXISTING\RAK-EX-ETISALAT LINES.dwg
UTILITIES EXISTING\RAK-EX-FEWA-Electrical Lines.dwg
UTILITIES EXISTING\RAK-EX-RAK GAS.dwg
UTILITIES EXISTING\RAK-EX-TRANSCO WATER LINES 600 & 800 MM.dwg
UTILITIES EXISTING\RAK-EX-Transco-400kv OHL.dwg
UTILITIES EXISTING\RAK-EX-FEWA WATER LINES.dwg
AutoCAD Font Map References:
acad.fmp
AutoCAD Color-dependent Plot Style Table File References:
PlotCfgs\222222.ctb
PlotCfgs\BLACK.ctb
AutoCAD Plotter Configuration File References:
PlotCfgs\DWG To PDF.pc3
JPEG Image References:
xref\DC_Abu_Dhabi_w.jpg
xref\uae-logo.jpg
The following files were excluded from the transmittal:

Fonts\simplex.shx
Fonts\txt.shx
Fonts\romand.shx
Fonts\arial.ttf
Fonts\ROMANS.shx
Fonts\calibri.ttf
Fonts\arialbd.ttf
Fonts\romanc.shx
Fonts\times.ttf
Fonts\romant.shx
Fonts\ltypeshp.shx
Fonts\romantic.ttf
Fonts\sanss___.ttf
Fonts\ARIALN.TTF
Fonts\ARIALUNI.TTF
Fonts\isocp.shx
Fonts\gbenor.shx
Fonts\trebuc.ttf
Fonts\tahoma.ttf
Fonts\l_10646.ttf
The following files could not be located:
ENGINEERING.(shx,ttf)
WORKING.(shx,ttf)
LOW_RES_FILLED.(shx,ttf)
x-hlvm1d.(shx,ttf)
Conversion:
All drawing files were converted to AutoCAD 2004/LT 2004 format.
Notes for distribution:
.DWG external reference files:
External reference (xref) paths may be present. Make sure these paths work or t
hat the root drawing is using the correct references.
eTransmit does not include files required by xrefs unless they are also required
by the root drawing. In particular, plot style tables and overlay xrefs that a
re not used by the root drawing are omitted
Raster image files:
Paths may be present on references to raster images. Make sure these paths work
or that the root drawing is using the correct references.
.PC3 printer configuration files:
Please copy these files to the AutoCAD Printer Configuration Search Path directo
ry.
.CTB/.STB plot style tables:
Please copy these files to the AutoCAD Plot Style Table Search Path directory.
The AutoCAD variable FONTALT was set to:
C:\Documents and Settings\vijay.chougule\Application Data\Autodesk\AutoCAD 2007\
R17.0\enu\support\simplex.shx
Please make sure that the FONTALT variable is set to this file or an equivalent
before opening any drawings. All text styles with missing fonts are automatical
ly set to this font.

Anda mungkin juga menyukai