Anda di halaman 1dari 20

Q.

1) Size of water piping shall be based on the total _________


A. Water consumption
B. Water demand (Your Answer)
C. Water potability
D. None of the above
Correct
Q.2) Water closet bowls for________ use shall be elongated bowl types equipped
with open-front seats.

A. Public (Your Answer)


B. Private
C. Government
D. None of the above
Correct
Q.3) Wastewater drain for _________ cupsink at church altar & baptisteries font

outlet shall discharge direct to the ground & not connected to any sanitary or
drainage system.

A. Holy sink
B. Lavatory
C. Baptismal shrine
D. Sacrarium (Your Answer)
Correct
Q.4) Tunnels shall have: the following except
A. A clear height of 0.6m above the pipe & shall be limited in length to 1/2
the depth of the trench.
B. Driven pipes shall have at least one pipe size larger than the pipe to be laid
C. Shall be back-filled in thin layers of 0.3m above the top of the pipe with
clean earth which shall not contain stones, boulders, cinders or other
materials which can damage or break the pipes or cause corrosive
action. (Your Answer)
D. None of the above
Correct
Q.5)

the

minimum cross sectional area at the seat of the control valve or the supply pipe
or tubing which feeds the device outlet. If two or more lines supply one outlet, the
effective opening shall be the sum of the cross-sectional areas of the individual

supply lines or the area or the single outlet, whichever is smaller.

A. Effective opening (Your Answer)


B. Effective depth
C. Effective area
D. Effective invert
Correct
Q.6) Suspended cast iron soil pipe shall be supported at not more than ____m

intervals, except that pipe exceeding 1.5m length may be supported at not more
than _____m intervals. Supports shall be adequate to maintain alignment & to
prevent sagging & shall be placed within 0.45m of the hub or joint.

A. 1.5/ 3 (Your Answer)


B. 1.5/ 4
C. 3/ 1.5
D. 4/ 1.5
Correct
Q.7) No water closet or bidet shall be set closer than ______m from its center to any
side of the wall or obstruction or closer than ______m center to centerto any
similar fixture.

A. .375 / 0.75 (Your Answer)


B. .375 / 0. 70
C. .40 / 0.70
D. .50 / 0.60
Correct
Q.8) Lead Pipe

- shall be supported at by____________for entire lengthwith


hangers properly spaced.

A. Stiff aluminum or wooden backing


B. Stiff metal or wooden backing (Your Answer)
C. Stiff plastic or metal sheet
Correct
Q.9) Fixtures having concealed slip joint connections shall be provided with an access
panel or utility at least ______m in its least dimension for inspection & repair.

A. 0.30 (Your Answer)


B. 0.20
C. 0.10
D. 0.40
Correct

Q.10) Excessive water pressure water pressure greater than ____ Kpa
A. 551 (Your Answer)
B. 552
C. 553
D. 554
Incorrect
Q.11) drains shall have a waterway equivalent area of the tailpiece meaning, the sum
of all the areas of the perforation of the strainer is equivalent to the outlet area.

A. Strainers serving bathub


B. Strainers serving shower (Correct Answer)
C. Strainers serving lavatory (Your Answer)
D. None of the above
Correct
Q.12) Copper Tubing - shall be supported at approximately ________m intervalsfor

piping 38mm diameter & smaller & _______m intervals for piping 51mm & larger
in dia.

A. 1.8/ 3.0 (Your Answer)


B. 1.9/ 3.5
C. 1.5 / 2.5
D. None of the above
Incorrect
Q.13) Continuous waste fixture tailpiece connections were exposed or accessible
may be of seamless drawn brass not less than Ga. 20 B&S or ______mm thk.

A. 0.90
B. 0.80 (Correct Answer)
C. 0.70
D. 0.60 (Your Answer)
Correct
Q.14) All porcelain enamel surfaces on plumbing fixtures shall be __________
A. Mold resistant
B. Acid resistant (Your Answer)
C. Corrosion resistant
D. None of the above
Incorrect

Q.15) All pipe determinations shall be based on eighty percent (___) the reduced
pressure.

A. 70% (Your Answer)


B. 60%
C. 80% (Correct Answer)
D. 90%
Correct
Q.16) ______________ must be supported at least every other joint except that when the
developed length between supports exceeds 1.2m, they shall be provided at each
joint.

A. Couplings and compression joints


B. Hubless or compression gasket joints (Your Answer)
C. Caps and plugs
D. None of the above
Correct
- shall be supported by stiff metal or wood backing with hangers in its
entire length for small-size tubings up to 38mm diameter &without backings but
with spaced metal hangers at approved spacingfor larger-size tubings.

Q.17) ____________

A. Steel tube
B. Plastic tube (Your Answer)
C. Aluminum tube
D. Concrete tube
Correct
Q.18) ________ m max. length of supply piping.
A. 61 (Your Answer)
B. 62
C. 63
D. 64
Correct
Q.19) If water closets or other plumbing fixtures are installed in the buildings where

there is no sewer within a reasonable distance, suitable provision shall be made


for disposing of the building sewage by some accepted method of sewage
treatment and disposal, such as ______________

A. WASTE TANK
B. SEPTIC TANK (Your Answer)
C. SEWAGE DISPOSAL SYSTEM
D. NONE OF THE ABOVE
Correct
Q.20) Drainage pipes shall be run in practical alignments & at a uniform slope

between manholes of not less than ______________ toward the point of disposal.

A. 20mm/m or 2% (Your Answer)


B. 30mm/m or 3%
C. 40mm/m or 4 %
D. 10mm/m or 1 %
Incorrect
Q.21) Changes in direction of piping shall be made by the use of approved pipe fittings &
shall be the angles presented by the following except

A. 22 degrees bend
B. 45 degrees bend (Your Answer)
C. 60 degrees bend or other approved fittings of longer sweeps
D. 30 degress bend (Correct Answer)
Correct
Q.22) All piping of plumbing systems shall be of durable ____________-APPROVED
materials, free from defective workmanship, designed and constructed by
Registered Master Plumbersto ensure satisfactory service.

A. NAMPAP (Your Answer)


B. DILG
C. DPWH
D. DENR
Incorrect
Q.23) a physical separation, which may be a low inlet into the indirect waste receptor from
the fixture, appliance or device indirectly connected

A. AIR SEPARATION (Your Answer)


B. AIR BREAK (Correct Answer)
C. AIR DEVISOR
D. NONE OF THE ABOVE
Correct
Q.24) a length of soil or waste stack corresponding in the general to a storey height, but

in no case less than 2.43m within which the horizontal branches from one floor

or storey of a building are connected to the stack.

A. BRANCH INTERVAL (Your Answer)


B. INTERVAL
C. BRANCH
D. LENGTH
Correct
Q.25) Each family dwelling unit on premises abutting on a sewer or with a private sewerdisposal system shall have at least ___ water closet and ___ kitchen-type sink

A. 1,2
B. 1,1 (Your Answer)
C. 2,1
D. 2,3
Incorrect
Horizontal drainage lines connecting to a vertical stack shall enter through
the following except,

Q.26)

A. 45 wye branches (Your Answer)


B. Combination wye & 1/8 bend branches
C. 30 wye bend (Correct Answer)
D. Or other approved fittings of longer sweeps.
Incorrect
Q.27) Horizontal drainage lines connecting to other horizontal drainage lines shall enter
through the following given below except:

A. 45 wye branches
B. Combination wye & 1/8 bend branches (Your Answer)
C. Or other approved fittings of longer sweeps.
D. 30 wye bend (Correct Answer)
Correct
Q.28) Birth of plumbing profession in the Philippines
A. INTRAMUROS (Your Answer)
B. BARASOAIN
C. BATAAN
D. CEBU
Incorrect
Q.29) Vertical drainage lines connecting to other horizontal drainage line shall enter
through

A. 45 wye branches
B. Or other approved fittings of longer sweeps.
C. 60 degree branches or offsets (only for pipes installed in true vertical
position(Your Answer)
D. 45 degree branches (Correct Answer)
Incorrect
Q.30)

No Drainage Fitting shall use:

A. Double hub fitting for leak-caulked joint in vertical position (Your Answer)
B. Single or double tee branch
C. Single or double tapped tee branch
D. Side inlet quarter bend, Running thread, band or saddle
E. All of the above (Correct Answer)
Incorrect
Q.31) ____________________may be used on vertical lines as a fixture connection.

(approved stainless steel bands with neoprene gaskets for jointing hubless cast iron
soil pipes are acceptable for use)

A. Single hub sanitary tapped tee (Your Answer)


B. Double hub sanitary tapped tee (Correct Answer)
C. Triple hub sanitary tapped tee
D. None of the above
Correct
Q.32) a minimum standard quantity of plumbing fixtures that discharge wastes into a
plumbing installation

A. Plumbing unit (Your Answer)


B. Plumbing fixtures
C. Plumbing system
D. Plumbing minimum
Correct
Q.33) In PROHIBITED FITTINGS & PRACTICES under this rule no ____________
shall be threaded.

A. GI soil pipe
B. Cast iron soil pipe (Your Answer)
C. PVC soil Pipe
D. None of the above
Correct

Q.34) Further, a _________ and bathtub or shower shall be installed to meet the basic
requirements of sanitation and personal hygiene.

A. SINK
B. LAVATORY (Your Answer)
C. BASIN
D. NONE OF THE ABOVE
Incorrect
Q.35) fixture directly connected to the drainage system shall be equipped with a
________.

A. VENTILATING SYSTEM (Your Answer)


B. WATER-SEALED TRAP (Correct Answer)
C. SOIL PIPES
D. WASTE PIPES
Incorrect
Q.36) Any such pipe or piping _______mm or larger in diameter may have a slope
of 10mm/m or 1% provided it is approved by Administrative Authority

A. 100 mm (Your Answer)


B. 102 mm (Correct Answer)
C. 101 mm
D. 104 mm
Correct
Q.37) Water pipes & fittings with a lead content that exceed ____ shall be prohibited &
shall not be used in potable piping systems.

A. 8% (Your Answer)
B. 9%
C. 10%
D. 11%
Correct
Q.38) Water Closet & Urinal Tanks shall be equipped with a listed ________ & shall be
installed with the critical level at least 25mm above the full opening of the
overflow pipe.

A. Corporation cock
B. Gatevalve
C. Ballcock (Your Answer)
D. None of the above
Correct

Q.39) THE TOTAL NUMBERS OF SET OF SANITARY/ PLUMBING PLANS


REQUIRED BY THE BUILDING OFFICIAL WHEN APPLYING FOR
PERMIT
A. 4
B. 5
C. 3
D. 6 (Your Answer)
Correct
Q.40) THE SANITARY AND PLUMBING PERMIT WILL BE REVOKE IF THE
PROJECT HAS BEEN ABANDONED OR SUSPENDED FOR HOW
MANY DAYS
A. 120 (Your Answer)
B. 60
C. 30
D. 100
Incorrect
Q.41) The quantity of water required to be supplied to every plumbing fixture shall be
represented by ____________

A. Fixture Units FU (Your Answer)


B. Fixture drain FD (Correct Answer)
C. Fixture Trap FT
D. None of the above
Correct
Q.42) the minimum airgap for Effective openings not greater than 25mm in diameter.
affected by walls

A. 2 times diameter of effective opening


B. 4 times diameter of effective opening
C. 5 times diameter of effective opening
D. 3 times diameter of effective opening (Your Answer)
Correct
Q.43) The minimum airgap for Effective openings not greater than 25mm in diameter. not
affected by walls

A. 3 times diameter of effective opening

B. 2 times diameter of effective opening (Your Answer)


C. 4 times diameter of effective opening
D. 5 times diameter of effective opening
Correct
Q.44) THE MINIMUM HEIGHT REQUIRED FROM THE FINISH GRADE
LINE THE SIAMESE INLET CONNECTION OF A STANDPIPE
A. 2.0 M
B. 1.2 M (Your Answer)
C. 1.5 M
D. 2.5 M
Correct
Q.45) The minimum air gap for Over rim bath fillers & other fixtures with effective
openings not greater than 25mm in diameter. affected by walls

A. 76mm (Your Answer)


B. 77mm
C. 78mm
D. 79mm
Correct
Q.46) The minimum air gap for Over rim bath fillers & other fixtures with effective
openingsnot greater than 25mm in diameter. not affected by walls

A. 54mm
B. 53mm
C. 52mm
D. 51mm (Your Answer)
Correct
Q.47) The minimum air gap for Lavatories & other fixtures with effective openings not
greater than 13mm in diameter if not affected by wall

A. 25 (Your Answer)
B. 24
C. 23
D. 22
Correct
Q.48) The minimum air gap for Lavatories & other fixtures with effective openings not
greater than 13mm in diameter if affected by walls

A. 36mm
B. 37mm

C. 38mm (Your Answer)


D. 39mm
Correct
Q.49) The minimum air gap for Sinks, laundry trays, goosenecks bath faucets & other
fixtures with effective openings not greater than 19mm in diameter. if not affected by wall

A. 40mm
B. 39mm
C. 38mm (Your Answer)
D. 37mm
Correct
Q.50) the minimum air gap for Sinks, laundry trays, goosenecks bath faucets & other
fixtures witheffective openings not greater than 19mm in diameter. if affected by wall

A. 56mm
B. 57mm (Your Answer)
C. 58mm
D. 59mm
Correct
Q.51) THE EXPIRATION OF THE PERMIT FOR SANITARY / PLUMBING
WILL BE EXPIRED AFTER HOW MANY YEARS FROM THE DATE OF
ISSUANCE
A. 2
B. 1 (Your Answer)
C. 1.5
D. 3
Correct
Q.52) THE DRAWINGS, SPECIFICATION, CALCULATIONS AND ETC FOR
PLUMBING / SANITARY PERMIT WILL BE SIGNED BY A a Registered
& Licensed
A. DRAINAGE ENGINEER
B. MASTER PLUMBER (Your Answer)
C. SANITARY ENGINEER
D. ARCHITECT
Correct
Q.53) Restaurant kitchen & other special-use sink may be made of approved-typed sheet
steel not less than Ga.16 U.S. B&S or 1.6mm thk.

A. Bonderized & galvanized (Your Answer)


B. Aluminum
C. Steel
D. None of the above
Incorrect
Q.54) No urinal shall be set closer than _________m center to center
A. 0.70 (Your Answer)
B. 0.60 (Correct Answer)
C. 0.50
D. 0.65
Correct
Q.55) No building sewer or other drainage pipings or part thereof, constructed of materials
other than that approved for use under or within the building, shall be
installed under or within _____ m of any building or structure, nor less than
0.3m below the finish ground surface

A. 0.60 (Your Answer)


B. 0.40
C. 0.30
D. 0.20
Incorrect
Q.56) No building water service pipe shall be less than _____mm in diameter
A. 21
B. 20 (Your Answer)
C. 25
D. 19 (Correct Answer)
Correct
Q.57) Inadequate water pressure water pressure less than _____ Kpa
A. 103 (Your Answer)
B. 104
C. 105
D. 106
Correct
Q.58) In Screwed Pipe - IPS shall be supported at approximately _______m

intervals for piping 19mm diameter & smaller & _______m intervals for piping
25mm & larger in diameter.

A. 3.5 / 3.0
B. 3.0 / 3.5
C. 3.6/ 3.0
D. 3.0 / 3.6 (Your Answer)
Correct
Q.59) In Ground

- piping buried on the ground shall be laid on the ______ for its
entire length, except where concrete cradle support is provided which is adequate
& approved by the Administrative Authority.

A. Firm bed (Your Answer)


B. Strata
C. Compacted earth
D. None of the above
Correct
Q.60) For EXCRETA DRAINAGE SYSTEM No Vitrified Clay Pipes or Fittings for building
drain or sewer shall be used above ground or whenever piping is pressurized by a
pump or ejector. They shall be kept ______m below finish ground level.

A. 0,30 (Your Answer)


B. 0.40
C. 0.50
D. 0.60
Correct
Q.61) For EXCRETA DRAINAGE SYSTEM No Galvanized Wrought
Iron orGalvanized Steel Pipe shall be used underground & shall be kept at least
_____mm above ground.

A. 155
B. 152 (Your Answer)
C. 153
D. 154
Incorrect
Q.62) For vertical piping,Screwed Pipe - Iron Pipe Size (IPS) shall be supported
at not less than every other storey

A. Drift
B. Height (Correct Answer)
C. Level (Your Answer)
D. Dimension

Correct
Q.63) For vertical piping, _________ - shall be supported at each storey or at
amaximum intervals of 3m o.c.

A. Lead tubing
B. Copper tubing (Your Answer)
C. Steel tubing
D. G.i. tubing
Correct
Q.64) For vertical piping, cast iron pipes- Bell & Spigot & Hubless pipe shall be
supported at_____ or closer.

A. Every 2 storey
B. Every storey (Your Answer)
C. Every 3 storey
D. Every 4 storey
Incorrect
Q.65) FOR THE SET OF SANITARY/ PLUMBING PLANS REQUIRED

BY THE BUILDING OFFICIAL WHEN APPLYING FOR


PERMIT HOW MANY SET OF DRAWINGS WILL BE
RETURNED ON THE APPLICANT
A. 1 (Your Answer)
B. 2 (Correct Answer)
C. 3
D. 4
Correct
Q.66) FOR THE SET OF SANITARY/ PLUMBING PLANS REQUIRED BY
THE BUILDING OFFICIAL WHEN APPLYING FOR PERMIT HOW
MANY SET OF DRAWINGS WILL BE PROVIDED FOR THE
ADMINISTRATIVE AUTHORITY
A. 1 (Your Answer)
B. 4
C. 3
D. 2
Correct
Q.67) FOR THE SET OF SANITARY/ PLUMBING PLANS REQUIRED

BY THE BUILDING OFFICIAL WHEN APPLYING FOR

PERMIT HOW MANY SET OF DRAWINGS WILL BE KEPT IN


THE JOB SITE
A. 2
B. 3
C. 1 (Your Answer)
D. 4
Correct
Q.68) Fixture unit Lawn Sprinklers (standard type, each head)
A. 1 (Your Answer)
B. 2
C. 1.5
D. 2.0
Incorrect
Q.69) fixture unit Water Closet (economical flush) private use
A. 5
B. 4 (Your Answer)
C. 3
D. 2.5 (Correct Answer)
E. 2
Correct
Q.70) Fixture unit of Urinal (stall & wall)
A. 5 (Your Answer)
B. 4
C. 3
D. 2
Correct
Q.71) Fixture unit of Urinal (pedestal or similar type)
A. 10 (Your Answer)
B. 15
C. 12
D. 9
Correct
Q.72) Fixture unit of Urinal (flush tank)
A. 2

B. 3 (Your Answer)
C. 4
D. 5
Correct
Q.73) fixture unit of Water Closet (flush tank & flushometer-tank),
Hose Bibb or Sill Cock (standard type) private use

A. 2
B. 3 (Your Answer)
C. 4
D. 5
Incorrect
Q.74) fixture unit of Water Closet (flush tank & flushometer-tank),
Hose Bibb or Sill Cock (standard type) public use

A. 5 (Correct Answer)
B. 4
C. 3 (Your Answer)
D. 2
Incorrect
Q.75) fixture unit of Water Closet (economical flush) public use
A. 5 (Correct Answer)
B. 4 (Your Answer)
C. 3
D. 2
Correct
Q.76) fixture unit of Mobile Home (each)-temporary facilities
A. 5
B. 6 (Your Answer)
C. 7
D. 8
Correct
Q.77) fixture unit of Bidet, Bathtub(With or Without Shower Over),Laundry Tub or
Clothes Washer (each pair of faucets), Shower (each head), Sink or
Dishwasher private use
A. 2 (Your Answer)
B. 3

C. 4
D. 5
Correct
Q.78) Fixture unit of bidet, Bathtub(With or Without Shower Over),Laundry Tub or
Clothes Washer (each pair of faucets), Shower (each head), Sink or
Dishwasher public use
A. 2
B. 3
C. 4 (Your Answer)
D. 5
Correct
Q.79) fixture unit Bar Sink, Drinking Fountain, Lavatory private use
A. 1 (Your Answer)
B. 2
C. 1.5
D. 2.5
Correct
Q.80) ficture unit Bar Sink, Drinking Fountain, Lavatory public use
A. 1
B. 2 (Your Answer)
C. 1.5
D. 2.5
Correct
Q.81) EXCRETA DRAINAGE SYSTEM what piping installations shall be used in high rise
buildings

A. ABS Acrylonitrile-Butadiene-Styrene
B. PVC (POLYVINYL CHLORIDE)
C. Vitrified clay pipe
D. A,b (Your Answer)
E. B,c
Correct
Q.82) consists of two independently acting internally or externally loaded check valves,
four properly located test cocks with connectors & two isolation gate valves.

A. ATMOSPHERIC VACUUM BREAKER (AVB


B. DOUBLE CHECK VALVE BACKFLOW PREVENTION ASSEMBLY
(DC) (Your Answer)

C. PRESSURE VACUUM BREAKER BACFLOW PREVENTION


ASSEMBLY (PVB)
D. None of the above
Incorrect
Q.83)

consists of two independently acting internally loaded check valves, a


differential pressure relief valve, four properly located test cocks & two
isolation gate valves.

A. PRESSURE VACUUM BREAKER BACFLOW PREVENTION


ASSEMBLY (PVB)(Your Answer)
B. REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTION
ASSEMBLY (RP) (Correct Answer)
C. ATMOSPHERIC VACUUM BREAKER (AVB
D. DOUBLE CHECK VALVE BACKFLOW PREVENTION ASSEMBLY
(DC)
Incorrect
Q.84) consists of a loaded air inlet valve, an internally loaded check valve, two properly located test cocks &
two isolation gate valves.

A. ATMOSPHERIC VACUUM BREAKER (AVB (Your Answer)


B. DOUBLE CHECK VALVE BACKFLOW PREVENTION ASSEMBLY
(DC)
C. PRESSURE VACUUM BREAKER BACFLOW PREVENTION
ASSEMBLY (PVB)(Correct Answer)
D. None of the above
Correct
Q.85) consist of a body, a checking member & an atmospheric opening.
A. ATMOSPHERIC VACUUM BREAKER (AVB (Your Answer)
B. DOUBLE CHECK VALVE BACKFLOW PREVENTION ASSEMBLY
(DC)
C. PRESSURE VACUUM BREAKER BACFLOW PREVENTION
ASSEMBLY (PVB)
D. None of the above
Correct
Q.86) All pipings passing under or through walls shall be protected from breakage with
embedded ________________.

A. Concrete pipe metal sleeves


B. Pvc pipe sleeves
C. Metal pipe sleeves (Your Answer)
D. None of the above

Correct
Q.87) All pipes passing through or under cinders or other corrosive materials shall be

protected from external corrosion by encasing same with _______ or in any other
approved manner.

A. Metal sheath
B. Polybuthane sheath
C. Polyethylene sheath (Your Answer)
D. Plastic sheath
Correct
Q.88)

_____________

- shall be supported at every 1m interval.

A. Plastic pipe (Your Answer)


B. Pvc pipe
C. Steel pipe
D. Lead pipe
Correct
Q.89)

in vertical piping ___________shall be supported at intervals not


exceeding 1.20m at centers with a rigid vertical back-up

A. PVC pipe
B. Lead Pipe (Your Answer)
C. Steel Pipe
D. G.I pipe
Correct
Q.90) In PROHIBITED FITTINGS & PRACTICES under this rule, No Drainage
or __________ shall be drilled & tapped for making connections thereto

A. Supply piping
B. Vent piping (Your Answer)
C. Drainage piping
D. None of the above
Incorrect
Q.91) No _____________ shall be located in a room or compartment,
which is not properly lighted & ventilated.

A. CATCH BASIN
B. LAVATORY (Your Answer)
C. BIBB
D. WATER CLOSET (Correct Answer)

Incorrect
Q.92) In GRADE OF HORIZONTAL PIPING If it is impracticable to obtain such slope due
to the following conditions except,

A. Excessive depth of the proposed drainage line


B. Structural and/or geological features of the terrain (Your Answer)
C. Existing adverse in arrangements of building structure
D. Reasonable change because of existing weather (Correct Answer)

Anda mungkin juga menyukai