DESIGN IN SUPPORT
THAT SAVES YOU TIME
As an architect or engineer youre always faced with tight time frames and lastminute changes. Thats why, with Georgia Powers Architects and Engineers
Program, you receive responsive support from pre-planning through commissioning.
Youll have one knowledgeable account executive who provides access to all the
technical expertise, troubleshooting and design assistance you need to meet
your deadlines. If youre ready for a partnership that works this hard for you,
call 1-888-655-5888 or visit georgiapower.com/AandE.
Table of Contents
Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Electric Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Ratcheted Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Time of Use Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Marginal Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Customer Choice in Georgia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Customer Choice Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
kWh vs. Therm Costs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Conversions between Fuel Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
HVAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Recommended Systems by Building Type. . . . . . . . . . . . . . . . . . . . . . . . 8
Cost Comparisons for System Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Typical EFLH for Buildings, Atlanta . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
City Factors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Typical Heating and Cooling Requirements . . . . . . . . . . . . . . . . . . . . . 11
Heat Gain from Typical Electric Motors. . . . . . . . . . . . . . . . . . . . . . . . . 13
Typical Equipment Energy Requirements . . . . . . . . . . . . . . . . . . . . . . . 14
EER Rating to kW Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Psychrometric Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Heat Recovery Opportunities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Building Envelope. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Sustainable Building Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Basic R-value information and calculations . . . . . . . . . . . . . . . . . . . . . 18
Ceiling Insulation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Wall Insulation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Glass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Slab Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Insulating Values for Common Building Materials . . . . . . . . . . . . 20
Basic Passive Solar Techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Water Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Water Heating Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Water Heating Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Water Use Charts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
System Wattages for Typical
Lamp/Ballast Combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Light Level Recommendations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Reflectance Values of Different Surfaces . . . . . . . . . . . . . . . . . . . . . . . 29
The Effect of Lighting on Cooling Load . . . . . . . . . . . . . . . . . . . . . . . . . 30
Annual Cost for Lighting Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Outdoor Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Cooking Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
How to Evaluate Energy Cost. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Equipment Input, Diversity, and Preheat Times. . . . . . . . . . . . . . . 37
Cooking Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Ventilation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Equipment Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Typical Equipment List Prices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Industrial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Compressed Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Typical Compressor Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Leakage Rate from Holes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Process Steam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Saturated Steam: Pressure Table . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Steam Loss from Leaks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Combustion Heat Losses, Gas Boilers . . . . . . . . . . . . . . . . . . . . . . 53
Electrical Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Useful Electrical Formulae for Determining Amperes,
Horsepower, Kilowatts and kVa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Estimating Loads From kWh Meter Clocking . . . . . . . . . . . . . . . . . . . . 67
Effects From Voltage Variations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Percent of Rated Heater Watts at Reduced Voltage. . . . . . . . . . . . . . 68
Motor Wattages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Ohm's Law Made Easy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
BTUHkWAmperes Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Transformer Types and Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Requirements For Service Conductors . . . . . . . . . . . . . . . . . . . . . . . . . 72
Motor Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Miscellaneous. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Diversity Factors for EFLH calculations . . . . . . . . . . . . . . . . . . . . . . . . . 74
Noise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Design Criteria for Room Loudness. . . . . . . . . . . . . . . . . . . . . . . . . 75
Room Sones dBA Correlation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Typical Weather Data for Metro Atlanta Area . . . . . . . . . . . . . . . . . . . 81
Climatic Conditions for Georgia Cities . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Wind Effect on Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Formulae . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Useful Web Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Rates
Rates
Electric Rates
Electric rates for commercial and industrial customers can
generally be categorized into three types:
Ratcheted, demand-based rates
Time of use rates
Marginal rates, including Real Time Pricing (RTP)
They differ in critical ways when it comes to calculations.
Ratcheted Rates
How to Recognize:
Ratcheted rates will have language in the tariff(s) like:
Hours use of demand
Billing demand
Tiered pricing structure (first block of kWh at one rate,
second block at another rate, etc.)
Rates
How to Recognize:
Time of use rates will have language in the tariff(s) like:
On-Peak, Off-Peak, Shoulder kWh and kW
Timed (or block) pricing structure
NOTE: there are market-based time of use rates that are real-time.
In Georgia Power, these are called real-time pricing. The prices
are confidential and are provided to the customer the day before
or hour before the price takes effect, depending on the contract.
In these cases, you will have to contact the utility to get blended
averages (see pricing calculation worksheet)
Rates
Rates
Marginal Rates
How to Recognize:
Marginal rates will have language in the tariff(s) like:
Hourly Prices
Customer Baseline Load (CBL)
Interval Data
Incremental kWhs
Demonstration
Under the Territorial Act of 1973, many customers over 900 kW who
are outside of municipal limits may choose their electric supplier. This
is a one-time, irrevocable choice.
Service
Reliability
Generation
Capability
Ancillary
Services
Rates
Rates
* Please refer to Page 91 for graph notations.
6
Gas:
1 Therm = 100,000 Btu = 100 CCF
1 cubic foot = 1,000 Btu
1 MCF = 1,000,000 Btu = 10 therms
Electricity:
1 kWh = 3,413 Btu
Liquid Gas (Propane):
1 cubic foot = 2,500 Btu
1 pound = 21,500 Btu
1 gallon = 91,160 Btu
Oil:
1 gallon = 140,000 Btu
Coal:
1 ton = 25 Million Btu
1 pound = 12,500 Btu
Rates
HVAC
Recommended Systems by Building Type
System #1
Hospitals
Schools
Through-the-wall units
Water source heat
in classroom.
pump with cooling
tower and boiler; split
system for offices;
package unit for
auditorium. Heat pump
water heater in kitchen.
Small electric water
heater in teachers
lounge.
Restaurants
Small
Offices/Retail
Hotels (small)
Through-the-wall heat
pump.
HVAC
Building Type
System #2
Building Type
System #1
System #2
Hotels (large)
Motels
Through-the-wall heat
pumps. Gas water
heater with
recirculating pump.
Churches
Weekend only:
Electric heat.
Weekday/school
buildings: Package unit
heat pumps.
HVAC
EFLH, Heating
HVAC
2000
2200
2400
1500
1800
2000
2500
2500
1600
3000
1800
1000
2000
2000
600
1500
1500
800
700
500
800
800
800
800
500
800
1500
800
800
800
800
400
800
800
Cooling Factor
Heating Factor
City Factors
City
Alma
Brunswick
Macon
Rome
1.37
1.48
1.33
.96
.61
.53
.75
1.03
Type of Bldg.
Btuh/SF,
Cooling
Apartments
24
Audit. & Theater
40
Banks
49
Barber Shops
46
Bars & Taverns
120
Beauty Parlors
63
Bowling Alleys
38
Churches
35
Cocktail Lounges
65
Comp. Rooms
141
Dental Offices
50
Dept. Stores
Basement
33
Dept. Stores
Main Floor
39
Dept. Stores
Upper Floors
29
Dormitory, Rooms 38
Dormitory, Corridors 20
Dress Shops
40
Drug Stores
77
Factories
39
High Rise Office
Ext. Rooms
43
High Rise Office
Int. Rooms
35
Hospitals
69
Hotel, Guest rooms 35
Hotel, Corridors
28
SF/ton,
Cooling
500
300/19*
245
260
100/10*
190
315
340/21*
185
85
240
Btu/SF,
Heating
21
38
48
44
114
60
37
33
63
20
49
Supply
CFM/SF
0.8
1.3
1.6
1.5
4.0
2.1
1.3
1.2
1.6
4.7
1.7
360
32
1.1
310
38
1.3
410
320
600
300
155
310
28
35
18
39
75
38
1.0
1.3
0.7
1.3
2.6
1.3
280
41
1.4
340
175
345
425
33
67
35
27
1.2
2.3
1.2
0.9
11
HVAC
HVAC
Btuh/SF
Cooling
Hotel, Public Spaces 51
Industrial Plants,
Offices
35
General Offices
33
Plant Areas
38
Libraries
43
Low Rise Office,
Ext. Rooms
39
Low Rise Office,
Int. Rooms
33
Medical Centers
35
Motels
29
Office (small suite) 40
Post Office,
Ind. Office
40
Post Office,
Central Area
43
Residences
20
Restaurants
60
Schools & Colleges 42
Shoe Stores
53
Shopping Centers,
Supermarkets
30
Retail Stores
32
Specialty Stores
57
Schools, Elem.
36
Schools, Middle
36
Schools, High
33
Schools, Vo-Tech 22
SF/ton
Cooling
235
Btu/SF
Heating
48
Supply
CFM/SF
1.7
345
360
315
280
34
32
37
40
1.2
1.1
1.3
1.4
310
32
1.3
365
340
420
300
32
33
27
38
1.1
1.2
1.0
1.3
300
39
1.3
280
600
200
285
225
41
20
60
40
52
1.4
0.7
2.0
1.4
1.8
400
370
210
335
335
365
550
28
31
57
32
32
32
20
1.0
1.1
1.9
1.2
1.2
1.1
0.8
* People/Ton
12,000 Btu = 1 ton of air conditioning
12
Split Ph.
0.33
Split Ph.
1750
56
1,500
840
660
0.50
Split Ph.
1750
60
2,120
1,270
850
0.75
3-Ph.
1750
72
2,650
1,900
740
3-Ph.
1750
75
3,390
2,550
850
3-Ph.
1750
77
4,960
3,820
1,140
3-Ph.
1750
79
6,440
5,090
1,350
3-Ph.
1750
81
9,430
7,640
1,790
Motor
Type
3-Ph.
1750
82
15,500
12,700
2,790
7,5
3-Ph.
1750
84
22,700
19,100
3,640
10
3-Ph.
1750
85
29,900
24,500
4,490
15
3-Ph.
1750
86
44,400
38,200
6,210
20
3-Ph.
1750
87
58,500
50,900
7,610
25
3-Ph.
1750
88
72,300
63,600
8,680
30
3-Ph.
1750
89
85,700
76,300
9,440
40
3-Ph.
1750
89
114,000
102,000
12,600
50
3-Ph.
1750
89
143,000
127,000
15,700
60
3-Ph.
1750
89
172,000
153,000
18,900
75
3-Ph.
1750
90
212,000
191,000
21,200
100
3-Ph.
1750
90
283,000
255,000
28,300
125
3-Ph.
1750
90
353,000
318,000
35,300
150
3-Ph.
1750
91
420,000
382,000
37,800
200
3-Ph.
1750
91
569,000
509,000
50,300
250
3-Ph.
1750
91
699,000
636,000
62,900
Copyright 1989, American Society of Heating, Refrigeration and Air-Conditioning Engineers, Inc.
www.ashrae.org. Reprinted by permission from 1989 ASHRAE Handbook Fundamentals.
13
HVAC
Motor
Nameplate or
Rated
Horsepower
0.25
HVAC
Rooftop
package unit
Water-source
heat pump
with cooling
tower and boiler
4-pipe system,
chilled water,
boiler, air handlers
2-pipe system,
chilled water, boiler,
air handlers
Split-system,
residential
Split-system,
commercial
Heat pump,
split-system
Heat pump, package
Ground water
source heat pump
kW/ton,
Cooling
Heating System
Efficiency
(electric)
Heating System
Efficiency
(gas)
0.9-1.3
0.95
0.75-0.77
0.86-1.1
2.0
1.8-1.9
0.8-1.3
0.8
0.6-0.7
0.75-1.1
0.82
0.6-0.7
1.0-1.2
0.95
0.7-0.92
0.7-1.3
0.95
0.75-0.77
1.0-1.2
0.9-1.3
2.3
2.3
N/A
N/A
0.38-0.5
2.8
N/A
Note: the heating efficiency considers heat exchanger losses, fan requirements,
pump power, and other losses.
kW, Cooling
2.0
1.85
1.71
1.60
1.50
1.41
1.33
EER Rating
9.5
10.0
10.5
11.0
12.0
13.0
14.0
14
kW, Cooling
1.26
1.20
1.15
1.09
1.0
0.92
0.86
15
Normal Temperature
Barometric Pressure: 29,921 Inches of Summary
Copyright 1992
American Society of Heating, Refrigeration
and Air-Conditioning Engineers, Inc.
www.ashrae.org
Reprinted by permission.
HVAC
HVAC
Runaround System
When the outdoor air intake and exhaust air duct are not in close
proximity, heat transfer can be accomplished by circulating an
ethylene glycol solution. One finned tube heat exchanger is located in
the outdoor air stream, one in the exhaust air stream, with the two being
connected by a pipe loop. A pump circulates the liquid for heat transfer.
Heat Pipe
A heat pipe is a sealed, static tube in which a refrigerant transfers heat
from one end of the device to the opposite end. The device is installed
through adjacent walls of inlet and exhaust ducts with their opposite
ends projecting into each air stream. A temperature difference
between the ends of the pipe causes the refrigerant to migrate by
capillary action to the warmer end where it evaporates and absorbs
heat. It then returns to the cooler end, condenses, and gives up the heat.
16
17
HVAC
Economizer
Building Envelope
Sustainable Building Design
Theres more of a focus now on sustainable buildings. This term is
used for buildings that have considerably lower impact on the
environment during both construction and long-term operation than a
typical building of similar size and location. Its very important to take
local conditions (economic and environmental) into account when
designing a low-impact building.
Building Envelope
There arent rules of thumb available yet. The most active groups in
this movement recommend modeling the building to assess the
energy-using features.
Ceiling Insulation
Flat
Steel
Insulation
No
1 insulation
(R-3 or R-4/
Deck,
inch)
No
Ceiling 3 insulation
(R-3 or R-4/
inch)
No
Frame insulation
Roofing, R-11
Attic,
insulation
Ceiling R-19
insulation
kW/
U
TD Btu/hr/ Tons/
TD Btu/hr/
1000
Factor (Cool) 1000 SF 1000 SF (Heat) 1000 SF
SF
.64
80
51200
4.26
48
30720
9.0
.23
80
18400
1.53
48
11040
3.23
.10
80
8000
0.67
48
4800
1.41
.15
55
8250
0.69
48
7200
2.11
.07
55
3850
0.32
48
3360
0.98
.04
55
2200
0.18
48
1920
0.56
Wall Insulation
Wall
Type
Insulation
No
insulation
4 Face
Brick 1
Cavity insulation
(R-5/inch in
8
Concrete Cavity)
Block 2
insulation
(R-5/inch in
Cavity)
kW/
U
TD Btu/hr/ Tons/
TD Btu/hr/
1000
Factor (Cool) 1000 SF 1000 SF (Heat) 1000 SF
SF
.30
22
6600
0.55
48
14400
4.22
.11
22
2420
0.20
48
5280
1.55
.07
22
1540
0.128
48
3360
0.98
19
Building Envelope
Roof
Type
TD
(Cool)
Btu/hr/
1000
SF
Tons/
1000
SF
TD
(Heat)
Btu/hr/
1000
SF
kW/
1000
SF
Single
1.06
14
1484
0.124
48
5424
1.589
Double, 1/4
air space
0.61
14
854
.071
48
3120
0.914
Prime +
Storm
Window
0.54
14
756
.063
48
2688
0.788
Insulation
U
Factor
TD
(Cool)
Btu/hr/
100
LF
Tons/
100
LF
TD
(Heat)
Btu/hr/
1000
LF
kW/
100
LF
No Insulation
0.81
48
3888
1.14
1" Insulation
(R-5 /inch)
0.41
48
2968
0.58
2" Insulation
(R-5 /inch)
0.21
48
1008
0.30
Glass
Type
Building Envelope
Slab Floor
Materials
R Value U Value*
Cellulose Fiber Blown In3 1/2" . . . . . . . . . . . . . . . . . 13.0 . . . . . . . 0.077
Concrete, Block8" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.11 . . . . . . 0.900
Concrete, Block (Cores filled with vermiculite)8" . 1.94 . . . . . . 0.515
Concrete, Poured10" . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 . . . . . . . 1.0
Expanded Polyurethane1". . . . . . . . . . . . . . . . . . . . . . 6.25 . . . . . . 0.16
Expanded Polyurethane2". . . . . . . . . . . . . . . . . . . . . 12.5 . . . . . . . 0.08
Extruded Styrofoam1" . . . . . . . . . . . . . . . . . . . . . . . . . 5.4 . . . . . . . 0.185
Flexicore4", 8", 10" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.89 . . . . . . 1.124
Glass Block. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.38 . . . . . . 0.42
Gypsum Board1/2" . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.45 . . . . . . 2.222
Insulation Board1/2". . . . . . . . . . . . . . . . . . . . . . . . . . . 1.52 . . . . . . 0.657
Plaster with metal lath3/4" . . . . . . . . . . . . . . . . . . . . . 0.23 . . . . . . 4.347
Plywood3/8" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.47 . . . . . . 2.127
Roof Deck1" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.78 . . . . . . 0.36
Sheathing and flooring3/4" . . . . . . . . . . . . . . . . . . . . . 0.92 . . . . . . 1.086
Shingles, asbestos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.21 . . . . . . 4.76
Shingles, wood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.78 . . . . . . 1.282
Siding, drop3/4" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.28 . . . . . . 0.781
Steel Doors: 1 3/4" mineral fiber core . . . . . . . . . . . . . . 1.7 . . . . . . . 0.59
1 3/4" urethane foam core with thermal break . . . 5.26 . . . . . . 0.19
1 3/4" polystyrene core with thermal break. . . . . . 2.13 . . . . . . 0.47
Siding, lap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.78 . . . . . . 1.282
Surface, inside (air film). . . . . . . . . . . . . . . . . . . . . . . . . . 0.68 . . . . . . 1.47
Surface, outside (15 mile per hour wind). . . . . . . . . . . 0.17 . . . . . . 5.882
Windows: Single glass, outdoor exposure . . . . . . . . . 0.88 . . . . . . 1.136
Double glass, 1/4" apart . . . . . . . . . . . . . . . . . . . . . . . 1.54 . . . . . . 0.649
Double glass, 1/2" apart . . . . . . . . . . . . . . . . . . . . . . . 1.72 . . . . . . 0.581
Triple glass, 1/4" apart . . . . . . . . . . . . . . . . . . . . . . . . 2.13 . . . . . . 0.469
Wood: Hardwoods (Maple, Oak, etc.)1" . . . . . . . . . 0.91 . . . . . . 1.099
Softwoods (Pine, Fir, Cedar, etc.)1". . . . . . . . . . . . . . 1.25 . . . . . . 0.8
Wood Doors1 1/2" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.04 . . . . . . 0.49
Wood Doors1 1/2" w/Storms . . . . . . . . . . . . . . . . . . . 3.7 . . . . . . . 0.27
1
*U=R
U x Temperature Difference = heat loss in watts per square foot.
21
Building Envelope
Building Envelope
Technique
What it Does
Overhang on South-facing
windows
Low-emissivity glass
22
Water Heating
System
Type
Application
Considerations
Tank-Style
Typical potable
water requirements:
small office areas,
retail, etc.
Boiler
Point-of-Use
Small medical
offices, remote
washrooms.
Thermal
Storage
Hospitals, industrial
sites, schools.
Laundries, kitchens,
Heat Pump
Water Heater pools.
Provides dehumidification as
well. Must be sized to meet
either cooling or water
heating load.
23
Water Heating
Water Heating
Total Use
Dishwasher Booster***
0.6 kWh
0.2 kWh
0.2 kWh
0.04 kWh
24
Mens
Dormitories
3.8 gal/student
Womens
Dormitories
5.0 gal/student
Motels:
No. of Units
20 or less
6.0 gal/unit
60
5.0 gal/unit
100 or more
4.0 gal/unit
Nursing Homes
4.5 gal/bed
Office
Buildings
0.4 gal/person
Food Service
Establishments 1.5 gal/maximum
Type A-Full Meal meals/hours
Restaurants
& Cafeterias
Type B-Driveins, Grilles,
Luncheonettes, 0.7 gal/maximum
Sandwich &
meals/hour
Snack Shops
Apartment Houses:
No. of Apartments
20 or less
12.0 gal/apt.
50
10.0 gal/apt.
75
8.5 gal/apt.
100
7.0 gal/apt.
200 or more
5.0 gal/apt.
Elementary
Schools
0.6 gal/student
Junior &
Senior High
1.0 gal/student
Schools
Maximum
Daily
Average
Daily
22.0 gal/student
13.1 gal/student
26.5 gal/student
12.3 gal/student
35.0 gal/unit
25.0 gal/unit
15.0 gal/unit
30.0 gal/bed
20.0 gal/unit
14.0 gal/unit
10.0 gal/unit
18.4 gal/bed
2.0 gal/person
1.0 gal/person
11.0 gal/maximum
meals/hour
2.4 gal/average*
meals/day
6.0 gal/maximum
meals/hour
0.7 gal/average*
meals/day
80.0 gal/apt.
73.0 gal/apt.
66.0 gal/apt.
60.0 gal/apt.
50.0 gal/apt.
42.0 gal/apt.
40.0 gal/apt.
38.0 gal/apt.
37.0 gal/apt.
35.0 gal/apt.
1.5 gal/student
0.6 gal/student*
3.6 gal/student
1.8 gal/student
25
Water Heating
Type of
Building
Vegetable Sink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Single Compartment Sink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Double Compartment Sink. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Triple Compartment Sink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Pre-Rinse for Dishes-Shower Head Type (Hand Operated) . . . . . . . 45
Pre-Scraper for Dishes (Salvajor Type) . . . . . . . . . . . . . . . . . . . . . . . . 180
Pre-Scraper for Dishes (Conveyor Type) . . . . . . . . . . . . . . . . . . . . . . . 250
Bar Sink (Three Compartment). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Bar Sink (Four Compartment) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Chemical Sanitizing Glasswasher . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Lavatory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Service Sink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Cook Sink. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
9-12 Pound Washers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
16 Pound Washers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Shower. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Water Heating
*From Guideline for Hot Water Generating Systems for Food Service
Establishments. Michigan Department of Public Health.
27
Lighting
Lamp Type
Ballast Type (No.)
No. of Lamps
40 Watt T12 34 Watt T12 32 Watt T6 F96/75W/SL F96/60W/SL F96/59W/T8 F96/110W/HO F96/215W/VHO F96/215W/VHO F96/185W/VHO
N/A
N/A
98
83
135
125
230
200
41
Standard (1) 1-Lamp
49
Energy Eff. (1) 1N/A
N/A
N/A
N/A
N/A
N/A
N/A
52
37
44
Lamp
Electronic (1)
N/A
N/A
N/A
N/A
N/A
N/A
86
35
34
28
1-Lamp
Electronic (1)*
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
32
1-Lamp
N/A
N/A
Standard (1) 2-Lamp
79
96
175
138
257
219
440
375
Energy Eff. (1)
N/A
N/A
N/A
86
158
123
237
199
70
70
2-Lamp
Electronic (1)
N/A
N/A
105
118
194
160
69
134
62
57
2-Lamp
Electronic (1)*
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
102
51
2-Lamp
Standard (2)
N/A
148
127
3-Lamp
All wattages are +/- 4 Watts. The actual wattages depend on the
Energy Eff. (2)
134
107
109
specific manufacturer's lamp and ballast combinations.
3-Lamp
Electronic (1)
108
88
90
3-Lamp
Lumen output also varies with lamp/ballast combinations.
Electronic (1)*
N/A
N/A
75
3-Lamp
Actual light output is dependent on the ballast factor.
Standard (2)
N/A
192
158
4-Lamp
Energy Eff. (2)
*These ballasts are low power ballasts. In addition to consuming
172
140
140
4-Lamp
less energy, they will result in reduced light output.
Electronic (1)
142
108
114
4-Lamp
Electronic (1)*
N/A
N/A
95
4-Lamp
Lighting
Lighting
25
50
75
100
125
28
150
175
200
Material Category
Description
Glass
Clear or Tinted
Reflective
5-10
20-30
Masonry
Brick, Red
Cement, Gray
Granite
Limestone
Marble, Polished
Plaster, White
Sandstone
10-20
20-30
20-25
35-60
30-70
90-92
20-40
Metals
Aluminum, Brushed
Aluminum, Etched
Aluminum, Polished
Stainless Steel
Tin
55-58
70-85
60-70
50-60
67-72
Paint
White
70-90
Wood
Light Birch
Mahogany
Oak, Dark
Oak, Light
Walnut
35-50
6-12
10-15
25-35
5-10
29
Reflectance (%)
Lighting
Lighting
Source
System
kW per
1,000,000
Lumens
Btu
Input*
Ton-hours
Cooling
Required*
57.1
194882
16.24
2,000
46.51
158749
13.23
20,000
13.9
47680
3.97
20,000
13.08
44642
3.72
20,000
11.71
39966
3.33
15,000+
11.37
38806
3.23
24,000
20.44
69762
5.81
20,000
11.625
39676
3.31
20,000
9.72
33174
2.76
Initial
Lamp
Lumens/ Hours
Watt
Life
Incandescent GE
100A A-19/F
17.5
Quartz GE
Q1000T3/CL
21.5
Fluorescent
Standard Ballast
F40CW
71.6
Fluorescent
Standard Ballast
F40LW/RS/WMII
76.5
Fluorescent
Max Miser I Ballast
f40CWIRS/WMII
85.4
Fluorescent
Optimiser System
FM28KW
87.9
Mercury-Regulator
(CW) Ballast
HR400DX33
48.9
Metal Halide
Auto Regulator
(Peak Lead) Ballast
MVR400/VBV
86.0
High Pressure
Sodium
102.9
750
*Assumes 2500 Hours Use of the Lighting System Annually, 1,000,000 Lumen Output
30
Outdoor Lighting
For Improved
Safety
Security
Appearance
Merchandising
Outdoor Lighting
Outdoor Lighting
32
33
Burning
Position
Any
Any
Any
Any
Any
Any
Any
Any
Any
Any
1500W
1000W(I)
1000W
400W(I)
400W
250W
250W(l)
175W
175W(l)
Vert.
Vert. (j)
Vert.
Vert. (j)
Vert.
Vert.
Horz. (k)
Vert.
Horz. (k)
24,000
24,000
24,000
24,000
24,000
24,000
24,000
24,000
24,000
24,000
3,000
12,000
12,000
20,000
20,000 (f)
10,000
10,000
10,000 (g)
6,000
1000W
400W
310W
250W
200W
150W
100W
70W
50W
35W
Light Source
155,000
115,000
110,000
40,000
36,000
19,500
23,000
14,000
12,000
140,000
50,000
37,000
30,000
22,000
16,000
9,500
6,300
4,000
2,250
(b) Initial
Lumens
95
110
105
87
78
65
77
67
71
127
108
97
98
88
80
70
66
64
50
Efficacy
.84
.73
.73
.68
.68
.76
.76
.67
.67
.83
.83
.82
.83
.82
.83
.83
.83
.83
.83
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
.65
.65
.65
.70
.70
.70
.70
.70
.70
.65
.70
.70
.70
.70
.70
.70
.70
.70
.70
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
.55
.48
.48
.48
.48
.53
.53
.47
.47
.54
.58
.57
.58
.57
.58
.58
.58
.58
.58
(c)
(d)
(e)
LLD x LDD = LLF
Outdoor Lighting
1,625
1,050
1,050
460
460
300
300
210
210
1,100
465
380
305
250
200
135
95
63
45
Lamp Table
Burning
Position
(a) Lamp Life
Vert.
Vert.
Vert.
Vert.
Vert.
Vert.
Vert.
Vert.
Fluorescent Lamps
1000W
400W
250W
175W
100W
75W
50W
40W
10,000 (h)
10,000 (h)
10,000 (h)
10,000 (h)
20,000+(h)
20,000 (h)
15,000 (h)
20,000 (h)
20,000+(h)
20,000 (h)
20,000+(h)
24,000 +
24,000 +
24,000 +
24,000 +
24,000 +
16,000 +
16,000 +
16,000 +
Light Source
250
400
600
900
3,150
2,925
3,350
2,900
3,250
2,900
3,250
63,000
22,500
12,100
8,600
4,200
2,800
1,575
1,140
(b) Initial
Lumens
8
10
12
16
48
40
48
40
48
40
48
1,060
450
300
210
120
99
74
61
31
40
50
56
66
73
67
72
66
72
67
59
50
40
41
38
32
21
19
Efficacy
Outdoor Lighting
34
.70(i)
.70(i)
.70(i)
.70(i)
.83
.83
.83
.83
.83
.83
.83
.50
.71
.74
.78
.67
.68
.68
.68
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
.65
.65
.65
.65
.65
.65
.65
.65
.65
.65
.65
.65
.70
.70
.70
.70
.70
.70
.70
= .46
= .46
= .46
= .46
= .54
= .54
= .54
= .54
= .54
= .54
= .54
= .32
= .50
= .52
= .55
= .47
= .48
= .48
= .48
(c)
(d) (e)
LLD x LDD = LLF
35
Burning
Position
20,000 (h)
20,000+(h)
20,000 (h)
20,000+(h)
20,000 (h)
18,000
18,000
18,000
18,000
12,500
11,250
15,000
15,000
1500W T-3
1000W T-3
500W T-3
200W T-3
Horz. (n)
Horz. (n)
Horz. (n)
Horz. (n)
2,000
2,000
2,000
1,500
Light Source
35,800
21,500
11,100
3,350
2,900
3,275
2,900
3,275
2,900
6,300
6,000
9,200
8,300
14,000
13,800
16,000
14,900
(b) Initial
Lumens
24
22
22
17
71
68
71
67
71
73
84
76
78
63
70
71
76
Efficacy
Outdoor Lighting
1500
1000
500
200
40
48
40
48
40
86
71
121
106
222
196
225
196
.95
.95
.95
.95
.83
.83
.83
.83
.83
.89
.89
.82
.82
.67
.67
.67
.67
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
.65
.65
.65
.65
.65
.65
.65
.65
.65
.65
.65
.65
.65
.60
.60
.60
.60
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
.62
.62
.62
.62
.54
.54
.54
.54
.54
.58
.58
.53
.53
.40
.40
.40
.40
(c)
(d)
(e)
LLD x LDD = LLF
Burning
Position
33,000
22,500
13,500
8,000
4,800
1,800
(b) Initial
Lumens
(a) Lamp life based: 10 hours per start for HID lamps
and 12 hours per start for fluorescent unless
otherwise noted.
(b) Initial lumens (after 100 hours).
(c) Lamp lumen depreciation at 70% rate life (LLD).
(d) Luminary dirt depreciation (LDD). For outdoor
luminaries only.
(e) Light loss factor (LLF). For outdoor luminaries only.
(f) Average rate life 20,000 hours (when operated
vertical 30). All other burning positions
15,000 hours.
(g) Average rated life 10,000 hours (when operated
vertical 30). All other burning positions 6,000 hours.
180W T-21
135W T-21
90W T-21
55W T-17
35W T-17
18W T-17
18,000
18,000
18,000
18,000
18,000
10,000
Light Source
150
126
108
100
71
60
Efficacy
1.00
1.00
1.00
1.00
1.00
1.00
x
x
x
x
x
x
.65
.65
.65
.65
.65
.65
= .65
= .65
= .65
= .65
= .65
= .65
(c)
(d) (e)
LLD x LDD = LLF
(h)
(i)
(j)
(k)
220
178
125
80
68
30
Outdoor Lighting
36
Cooking Equipment
How to Evaluate Energy Cost
Electric Cost/yr = Nameplate rating (kW) * Diversity Factor (default of .25)
* 12 * $/kW + kW * Diversity Factor * Hours per year * $/kWh
-ORTo estimate further (this is a reasonable estimate, since cooking will
be a flat load throughout the year):
Electric Cost/yr = kW * Diversity Factor * Hours per year * Average
$/kWh (from Table below)
Gas Cost/yr = Nameplate rating (Btuh) * Diversity Factor (default of .35)
* Hours per year * $/therm /100000 Btu per therm
Typical Input
Diversity (Elec/Gas)
Equipment Type
Fryer
(conventional), 45 #
Griddle, 3'
Deck Oven, 2-pan 5'
Convection Oven,
Single Full-Size
Conveyor Oven, 36"
Tilting Skillet, 40 gal.
Solid Top Range, 3'
Range Oven, 1 pan
Radiant Broiler, 3'
Charbroiler, 3'
Steam Jacketed
Kettle, 40 gal.
Electric Gas
(Btuh)
(kW)
Gas
120000
90000
75000
5-8
7-12
20-36
8-12
10-15
45-60
11
18
18
8
5
12
12
55000
120000
100000
80000
35000
50000
50000
9-10
20-40
8-13
7-15
20-36
5-10
8-11
20-30
30-40
5-9
10-30
20-30
15-20
20
18
110000
10-20
10-20
Electric
Gas
.20
.20
.20
.39
.40
.39
14
9
10
.18
.25
.20
.30
.20
.60
.60
.35
.45
.39
.80
.39
.95
.95
.20
.45
Note that diversity is different between electric and gas because of reheat,
thermal efficiency, and operational differences.
37
Cooking Equipment
Business Type
.085
.095
.095
.1
.05
.085
.08
.085
1.35
1.4
1.4
1.45
1.25
1.2
1.3
1.2
Fast Food
Full Service
Cafeteria
Church/Synagogue
Large Office Building
School (K-12)
College/University
Healthcare
Cooking Efficiency
Equipment
Cooking Equipment
Electric
.52
.65
.78
.83
.71
.73
.73
.62
.55
.45
.79
.23
.39
Gas
.22
.16
.28
.3
.51
.42
.38
.28
.24
.13
.52
.13
.19
Note: This represents the energy that is put into the food (as opposed to the kitchen or
up the flue). Source: Comparative gas/electric foodservice equipment energy
consumption ratio study, University of Minnesota, 3/3/83, p. 12. O.P. Snyder, D.R.
Thompson, J.F. Norwig.
38
Electric
Gas
20
35
35
85
60
65
75
25
60
40
100
70
75
150
For every 250 CFM reduction, AC load is reduced by 1.1 tons and heating requirement
is reduced by 13,200 Btuh.
Food Sales
FOOD COST
LABOR COST, BENEFITS
Pretax Profits
Rent, Property Tax, Insurance
Administration, General
Advertising, Promotion
UTILITIES
Supplies
Repair, Maintenance, Int.
Depreciation
100%
33.3
24
24
8
6
4.8
3.6
4
3.1
2.8
39
100%
31.5
29.1
29.1
7.9
6.5
2.6
0.48
3.2
2.6
2.8
Cooking Equipment
Equipment Considerations
Cooking Equipment
1. The cooking process is energy efficient only 50% of typical gas BTUs
2. This results in cooler kitchens, less or no A/C, more efficient employees
3. The equipment lasts longer
4. Does not require a flue
5. It is easier to balance the buildings air flow
6. Ovens are insulated on all six sides to conserve energy
7. Electricity is clean, providing for lower building maintenance costs
8. Water vapor and resulting humidity (bacteria, molds) are reduced
9. Equipment does not lose its efficiency with age
10. Kitchen design is easier and more flexible
Electric
$20,223
$4,908
$4,910
$5,485
$19,563
$26,129
$20,695
$12,308
$8,588
$11,449
Gas
$24,270
$5,152
$5,260
$5,977
$25,743
$33,578
$22,575
$14,000
$5,726
$16,679
40
Name
Trichlorofluoromethane
Application
Chillers (old)
12
Dichlorodifluoromethane
Chillers (old)
22
Chlorodifluoromethane
Small equipment,
heat pumps, A/C
units, cars
New chillers
New chillers,
cars, heat pumps
Food processing,
low-temperature
applications
Small equipment,
heat pumps, A/C
units, cars
Chillers
123 Dichlorotrifluoroethane
134a Tetrafluoroethane
717
Ammonia
Status
No longer
manufactured,
still available
No longer
manufactured,
still available
Phaseout scheduled
for 2010
Current
Current
Current
Current
Current
Application
High-rises; large
applications (150t+)
Reciprocating
100-120 t.
Screw,
Water-cooled
Absorption
75-300 t.
Industrial, 800-1000 t.
Considerations
Are most efficient run at full
load; lose efficiency rapidly
at partial loading
Lower capital expense; less
efficient than most alternatives
Good efficiency at partial
loading; can be noisy
Not generally economic unless
free steam is available.
Lower upfront cost, lower
installation, doesnt require
building space, less efficient
than water-cooled
High
Very High
Breakdown Torque
High
Medium
Low
% slip, max.
5%
5%
5% or more
Applications
Constant load
speed, low
inertia starts.
Fans,
compressors,
conveyors, etc.
Constant load
speed, high
inertia starts
Flywheels,
large
blowers, etc.
Variable load
speed, high inertia
starts. Hoists,
elevators, some
industrial
equipment
(punches,
some presses).
42
A
B
C
D
E
F
G
H
J
K
kVa/hp
0.0 3.15 3.55 4.0 4.5 5.0 5.6 6.3 7.1 8.0 -
Code Letter
3.15
3.55
4.0
5.0
5.0
5.6
6.3
7.1
8.0
9.0
L
M
N
P
R
S
T
U
V
kVa/hp
9.0 - 10.0
10.0 - 11.2
11.2 - 12.5
12.5 - 14.0
14.0 - 16.0
16.0 - 18.0
18.0 - 20.0
20.0 - 22.4
22.4 and up
The nameplate code rating is a good indication of the starting current the
motor will draw. A code letter at the beginning of the alphabet indicates a low
starting current and a letter at the end of the alphabet indicates a high starting
current. Starting current can be calculated using the following formula:
Code Letter
44
5 hp
1000 hpy Rewind/Std.
Efficiency
3000
Rewind/High
Eff.
5000
Rewind/High
Eff.
7000
Install New
High Eff.
8760
Install New
High Eff.
10 hp
15 hp
20 hp
30 hp
Rewind/Std.
Efficiency
Install New
High Eff.
Install New
High Eff.
Install New
High Eff.
Install New
High Eff.
Rewind/Std.
Efficiency
Install New
High Eff.
Install New
High Eff.
Install New
High Eff.
Install New
High Eff.
Rewind/Std.
Efficiency
Install New
High Eff.
Install New
High Eff.
Install New
High Eff.
Install New
High Eff.
Rewind/Std.
Efficiency
Install New
High Eff.
Install New
High Eff.
Install New
High Eff.
Install New
High Eff.
3 Assumes small business tax rate, 15% discount rate, PLM rate schedule, standard and high
efficiency as observed in supply catalogs, standard market prices. For any extensive motor
replacements/installations, please contact Georgia Power to find the best customized decision
60
72
75
77
79
81
82
84
85
86
87
88
89
89
Motor
Insider;
Equipment
Inside (Btuh)
Motor
Outside;
Equipment
Inside (Btuh)
Motor
Inside;
Equipment
Outside (Btuh)
2120
2650
3390
4960
6440
9430
15500
22700
29900
44400
58500
72300
85700
114000
1270
1900
2550
3820
5090
7640
12700
19100
24500
38200
50900
63600
76300
102000
850
740
850
1140
1350
1790
2790
3640
4490
6210
7610
8680
9440
12600
45
Motor
Insider;
Equipment
Inside (Btuh)
143000
172000
212000
283000
353000
420000
569000
699000
Motor
Outside;
Equipment
Inside (Btuh)
127000
153000
191000
255000
318000
382000
509000
636000
Motor
Inside;
Equipment
Outside (Btuh)
15700
18900
21200
28300
35300
37800
50300
62900
Copyright 2001, American Society of Heating, Refrigeration and Air-Conditioning Engineers, Inc.
www.ashrae.org. Reprinted by permission from 2001 ASHRAE Handbook Fundamentals.
Motor Formulae
Torque (lb-ft) = hp * 5250/RPM
Hp = Volts * Amps * Efficiency/746
% slip = (Synchronous RPM Full-load RPM)*100/Synchronous RPM
Speed
Specific To Correct
Gravity (SG)
for
Flow
Constant
Variable
Constant
Head
BHP
(or kW)
Flow
Variable
Constant
Constant
Constant
Constant
Head
Variable
BHP
(or kW)
BHP
(or kW)
Multiply by
Speed
( New
Old Speed )
Speed 2
( New
Old Speed )
Speed 3
( New
Old Speed )
Diameter
(New
Old Diameter )
Diameter 2
(New
Old Diameter )
Diameter 3
(New
Old Diameter )
New SG
Old SG
46
47
Duct Design
Rectangular Equivalent of Round Ducts
Industrial Applications
Industrial Applications
Compressed Air
Existing compressor capacity:
C = V(P2-P1)*60/(14.7*time)
Where:
C = capacity of compressor in cfm
V = receiver and piping volume in cu. ft.
P2 = final cutout pressure (absolute, psia)
P1 = initial pressure (absolute, psia)
Time = pump up time, in seconds
Additional Air Required = Existing Capacity * Desired Pressure/
Existing Pressure
49
Rotary Screw
4.0
1/64
1/32
3/64
1/16
3/32
1/8
3/16
1/4
3/8
1/2
5/8
3/4
7/8
1
1-1/18
1-1/4
1-3/8
1-1/2
1-3/4
2
0.062
0.248
0.568
0.993
2.23
3.97
8.93
15.9
35.7
63.5
99.3
143
195
254
321
397
482
572
780
1015
10
0.077
0.311
0.712
1.24
2.80
4.98
11.2
19.9
44.7
79.6
124.5
179.2
244.2
318.2
402.5
498
604
716
972
1274
15
0.105
0.420
0.944
1.68
3.78
6.72
15.2
26.9
60.5
108
168
242
329
430
544
672
816
968
1318
1720
0.123
0.491
1.10
1.96
4.41
7.86
17.65
31.4
70.7
126
196
283
385
503
637
784
954
1132
1540
2120
0.158
0.633
1.42
2.53
5.69
10.1
22.8
40.5
91.1
162
253
365
496
648
820
1019
1230
1460
1985
2594
0.194
0.774
1.75
3.10
7
12.4
28.0
49.6
112
198
310
446
607
793
1004
1240
1505
1783
2429
3173
0.23
0.916
2.06
3.66
8.25
14.7
33.0
58.6
132
235
366
528
718
938
1187
1464
1780
2112
2875
3752
0.267
1.06
2.38
4.23
9.5
16.9
38
67.6
152
271
423
609
828
1082
1370
1693
2054
2335
3310
4330
0.335
1.34
3.0
5.36
12.0
21.4
48.3
85.7
193
343
536
771
1050
1371
1734
2144
2607
3081
4200
5480
0.0406
1.62
3.66
6.49
14.6
26.0
58.5
104
234
415
649
934
1272
1661
2101
2596
3153
3734
5085
6650
Note: For well-rounded entrance, mu8ltiply values by 0.97; for sharp-edged orifices, multiply by 0.65
0.04
0.158
0.356
0.633
1.43
2.53
5.7
10.1
22.8
40.5
63.03
91.2
124
162
205
253
307
364
496
648
Dia. of
Orifice
(in.)
0.494
1.98
4.44
7.90
17.8
31.6
71.0
126
284
506
790
1138
1549
2023
2560
3160
3840
4550
6195
8100
125
0.583
2.23
5.25
9.1
20.9
37.3
84
149.3
336
596
932
1340
1825
2385
3020
3725
4525
5360
7300
9540
150
0.75
3.18
6.86
12.17
27.35
48.7
109.6
195
438
777
1216
1750
2382
3112
3940
4860
5910
7000
9530
12450
200
Industrial Applications
50
51
32.018
59.323
79.586
101.74
162.24
193.21
212.00
213.03
227.96
250.34
267.25
281.02
292.71
302.93
312.04
320.28
327.82
334.79
341.27
347.33
353.04
0.08865
0.25
0.5
1.0
5.0
10.0
14.696
15.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
110.0
120.0
130.0
140.0
Abs.
Press. Temp
(psi)
(F)
Process Steam
0.016834
0.017009
0.017151
0.017274
0.017383
0.017482
0.017573
0.017659
0.017740
0.01782
0.01789
0.01796
0.01803
0.016022
0.016032
0.016071
0.01636
0.016407
0.016592
0.016719
0.016726
vf
Sat.
Liquid
vg
vfg
20.070
13.7266
10.4794
8.4967
7.1562
6.1875
5.4536
4.8779
4.4133
4.0306
3.7097
3.4364
3.2010
20.087
13.7436
10.4965
8.5140
7.1736
6.2050
5.4711
4.8953
4.4310
4.0484
3.7275
3.4544
3.2190
3302.4
1235.5
641.5
333.6
73.532
38.420
26.799
26.290
Evap.
3302.4
1235.5
641.5
333.59
73.515
38.404
26.782
26.274
Sat.
Vapor
196.27
218.9
236.1
250.2
262.2
272.7
282.1
290.7
298.5
305.8
312.6
319.0
325.0
0.0003
27.382
47.623
69.73
130.2
161.26
180.17
181.21
hf
Sat.
Liquid
hg
hfg
960.1
945.2
933.6
923.9
915.4
907.8
900.9
894.6
888.6
883.1
877.8
872.8
868.8
0.3358
0.3682
0.3921
0.4122
0.4273
0.4411
0.4534
0.4643
0.4743
0.4834
0.4919
0.4998
0.5071
0.0000
0.0542
0.0925
0.1326
0.2349
0.2836
0.3121
0.3137
sf
Sat.
Liquid
1.3962
1.3313
1.2844
1.2474
1.2167
1.1905
1.1675
1.1470
1.1284
1.1115
1.0960
1.0815
1.0681
2.1872
2.0425
1.9446
1.8455
1.6094
1.5043
1.4447
1.4415
sfg
Evap.
Entropy
1.7320
1.6995
1.6765
1.6586
1.6440
1.6316
1.6208
1.6113
1.6027
1.5950
1.5879
1.5813
1.5752
2.1872
2.0967
2.0370
1.9781
1.8443
1.7879
1.7568
1.7552
sg
Sat.
Vapor
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
110.0
120.0
130.0
140.0
0.8865
0.25
0.5
1.0
5.0
10.0
14.696
15.0
Abs.
Press.
(psi)
p
Industrial Applications
1156.3
1164.1
1169.8
1174.1
1177.6
1180.6
1183.1
1185.3
1187.20
1188.9
1190.4
1191.7
1193.0
1075.5
1087.4
1096.3
1105.8
1131.1
1143.3
1150.5
1150.9
Evap.
1075.5
1060.1
1048.6
1036.1
1000.9
982.1
970.3
969.7
Sat.
Vapor
Enthalpy
Specific Volume
381.80
385.91
389.88
393.70
397.39
400.97
404.44
407.80
411.07
414.25
417.35
431.73
444.60
200.0
210.0
220.0
230.0
240.0
250.0
260.0
270.0
280.0
290.0
300.0
350.0
400.0
358.43
363.55
368.42
373.08
377.53
150.0
160.0
170.0
180.0
190.0
Abs.
Press. Temp
(psi)
(F)
0.01889
0.01912
0.01934
0.01839
0.01844
0.01850
0.01855
0.01860
0.01865
0.01870
0.01875
0.01880
0.01885
1.52384
1.30642
1.14162
2.2689
2.16373
2.06779
1.97991
1.89909
1.82452
1.75548
1.69137
1.63169
1.57597
1.54274
1.32554
1.16095
2.2873
2.18217
2.08629
1.99846
1.91769
1.84317
1.77418
1.71013
1.65049
1.59482
3.0139
2.8336
2.6738
2.5312
2.4030
vg
394.0
409.8
424.2
355.5
359.9
364.2
368.3
372.3
376.1
379.9
383.6
387.1
390.6
330.6
336.1
341.2
346.2
350.9
hf
2.9958
2.8155
2.6556
2.5129
2.3847
vfg
0.01809
0.01815
0.01821
0.01827
0.01833
vf
Sat.
Liquid
Specific Volume
Sat.
Sat.
Evap.
Liquid
Vapor
808.9
794.2
780.4
842.8
839.1
835.4
831.8
828.4
825.0
821.6
818.3
815.1
812.0
863.4
859.0
854.8
850.7
846.7
hfg
Evap.
Enthalpy
1202.9
1204.0
1204.6
1198.3
1199.0
1199.6
1200.1
1200.6
1201.1
1201.5
1201.9
1202.3
1202.6
1194.1
1195.1
1196.0
1196.9
1197.6
hg
Sat.
Vapor
0.5882
0.6059
0.6217
0.5438
0.5490
0.5540
0.5588
0.5634
0.5679
0.5722
0.5764
0.5805
0.5844
0.5141
0.5206
0.5269
0.5328
0.5384
sf
Sat.
Liquid
0.9223
0.8909
0.8630
1.0016
0.9923
0.9834
0.9748
0.9665
0.9585
0.9508
0.9433
0.9361
0.9291
1.0554
1.0435
1.0322
1.0215
1.0113
sfg
Evap.
Entropy
1.5105
1.4968
1.4847
1.5454
1.5413
1.5374
1.5366
1.5299
1.5264
1.5230
1.5197
1.5166
1.5135
1.5695
1.5641
1.5591
1.5543
1.5498
sg
Sat.
Vapor
300.0
350.0
100.0
200.0
210.0
220.0
230.0
240.0
250.0
260.0
270.0
280.0
290.0
150.0
160.0
170.0
180.0
190.0
Abs.
Press.
(psi)
p
Industrial Applications
52
Trap Orifice
Diameter (inches)
1/32
1/16
1/8
3/16
1/4
3/8
Pressure (psi)
15
100
150
300
0.85
3.4
13.7
30.7
54.7
123.0
3.3
13.2
52.8
119.0
211.0
475.0
4.8
18.9
75.8
170.0
303.0
682.0
9.8
36.2
145.0
326.0
579.0
1303.0
*in lb/hr.
A typical plant has a steam value of $5/1000 lbs. steam
53
Industrial Applications
Industrial Applications
Applications
Considerations
Ultraviolet
Coatings on heat
sensitive substrates.
Disinfection in water/
sewage treatment.
Fast curing.
No VOCs.
Low maintenance.
Induction
Plasma Arc
Microwave
New microwave
technologies allow web
drying applications. Best
for high value-added
products (high capital
cost).
Infrared
Comfort heating.
Process heating.
Powder Coating
Painting.
Ozonation
Laundry brightening.
Water disinfection.
No bleach required.
54
550
375
260
N/A
150
70
500
250
175
50
Hardening/
Solution
Treating
Annealing
Warm
Forming
70
Melting
250
Process
Tempering/
Aging
Curing
55
50
210
Stainless
NonSteel Magnetic
75
100
200
250
375
N/A
430
550
Stainless
Magnetic
90
120
250
240
400
300
450
500
Nickel
80
110
225
N/A
300
325
375
400
70
N/A
200
N/A
250
300
325
350
125
N/A
210
N/A
260
300
300
450
Industrial Applications
N/A
N/A
200
N/A
N/A
350
350
370
Industrial Applications
Materials
Coatings
Production
Heat Control
Scrap
Floor Space
Energy Costs
System Efficiency
Product Shape
Capital Cost
Labor Cost
Frequency
System Efficiency
Line Voltage
Solid State
Radio Frequency
60 Hz
60 to 200 kHz
200 to 450 kHz
65%
70%
50%
56
SHORT WAVE
(High Intensity)
Tungsten filament
lamps
T-3 quartz lamps
Type of
Emitter
MEDIUM WAVE
Coil or wire in
unsealed quartz,
silicon tubes, or
panels
LONG WAVE
(High Intensity)
Glass panels
Vitrified ceramic
panels
Typical
Applications
Curing painted
surfaces
Curing painted
surfaces
Activating adhesives
Curing powder
coatings
Curing powder
coatings
Polymerization of
organic coatings
on cooking utensils
Drying/heat setting
fabrics after dyeing
or printing
Gelling PVC
coatings on fabric
Drying textiles
Animal care in
agriculture
Printed circuit board
processing
Preheating plastic
Preheating wooden
panels prior to
coating
57
Industrial Applications
Industrial Applications
GAS CONVECTION
25 to 30 feet
Warm-up time
1 to 90 seconds
30 minutes
Cure time
1 second to 10 minutes
20 to 35 minutes
Efficiency
45 to 60%
15 to 25%
Product temperature
range
0 to 1000F.
0 to 450F.
Operational advantages
Ease of installation
Preassembled, move
into position
Erect on site
58
59
.24
.24
.24
.052
.031
.10
.10
.030
.12
.11
.13
.13
.12
.031
.04
.232
.11
.11
.11
.032
.057
.04
.12
.11
.11
.036
.056
.064
.126
.040
.095
Specific
Heat Btu/lb/F
Aluminum 1100
Aluminum 2024
Aluminum 3003
Antimony
Bismuth
Brass (70% Cu. 30% Zn)
Copper
Gold
Incoloy 800
Incoloy 600
Invar
Iron, cast
Iron, wrought
Lead, solid
Lead, melted
Magnesium
Monel 400
Nickel 200
Nichrome (80% Ni; 20% Cr)
Platinum
Silver
Solder (50% Pb; 50% Sn)
Steel, mild carbon
Steel, stainless, 304
Steel, stainless, 430
Tantalum
Tin, solid
Tin, melted
Titanium
Type Metal (85% Pb; 15% Sb)
Zinc
Substance
Metals
169
167
167
69
23
91
29
10
160
133
49
38
17
25
15
51
Heat of
Fusion Btu/lb
1190
935
1190
1166
520
1700
1981
1945
2475
2470
2600
2300
2800
621
1202
2370
2615
2550
3224
1761
415
255
2550
2650
5425
450
3300
500
787
Melting
Point
(lowest) F
169
173
170
423
610
525
550
1203
501
525
508
450
480
710
665
109
551
554
524
1338
655
580
490
488
475
1036
455
437
283
670
445
128
112
112
10.9
4.9
56
224
169
8.1
9.1
6.1
33
36
20
91
14
39
8.7
41
242
26
38
8.8
12.5
31
36
18
9.3
65
Thermal
Conductivity
Btu/hr/ft2
F
13.1
12.9
12.9
4.7-6.0
7.4
11.1
9.2
7.9
7.9
7.4
0.6
6.5
6.5
16.3
14
7.7
7.4
7.3
4.9
10.9
13.1
6.7
9.6
6.0
3.6
13
4.7
9.4-22
Linear Coefficient
of Thermal
Expansion
per F x 100
Industrial Applications
.098
.100
.099
.245
.353
.304
.318
.697
.290
.304
.294
.260
.278
.411
.385
.063
.319
.321
.303
.775
.379
.336
.284
.282
.275
.600
.263
.253
.164
.388
.258
Density
lb/ft3 lb/in3
Properties of Solids
Asbestos
Asphalt
Beeswax
Brickwork & Masonry
Carbon
Glass
Graphite
Ice
Magnesium Oxide
before compaction
compacted
Marinite-36 @ 600 F
Mica
paper
Paraffin
Pitch, hard
Plastics
ABS
Cellulosic
Epoxy
Fluoroplastic
Nylon
Phenolic
Polyethylene
Polystyrene
Vinyl
Quartz
Rubber
Soil dry
Steatite
Sugar
Sulfur
Tallow
Wood-oak
Wood-pine
Substance
Solid Non-Metals
40
75
63
17
.21
.21
.31
.20
.45
.70
.3-.4
.3-.5
.25
.28
.4
.3-.4
.55
.32
.2-.3
.21
.40
.44
.20
.30
.203
.45
.45
Heat of
Fusion Btu/lb
.25
.40
.22
.204
.20
.20
.46
Specific
Heat Btu/lb/F
3150
320
230
90
133
300
250
144
6700
2200
Melting
Point
(lowest) F.
Properties of Solids
138
95
100
105
125
60
50
34
36
58
56
83
36
65
60
140
165
130
57
.036.11.19
.048.10.20
.045.10.12
.077.14
.040.14
.048.085
.033.19.29
.037.03.08
.050.07.17
.080.80
.055
.058.035
.0941.7
.061
.072.15
.035
.029.12.20
.020.06.14
.1121.2
.021.068
.102.25
.034.068
.032.13
.048
.028.087
.038
.035
.081.38
.08013.8
.096.45
.075.104
.0331.28
Density
lb/ft3 lb/in3
3272
5583
2536
4658
.44
.38
55111
17111
28139
.30
.087
36
.3
7.7
1.3
18
36
.32.4
5
Thermal
Conductivity
Btu/hr/ft2
F
340
Linear Coefficient
of Thermal
Expansion
per F x 100
Industrial Applications
60
Specific
Heat
Btu/lb/
F
.472
.65
.45
Heat of
Vaporization
Btu/lb
153
365
166
Boiling
Point
F
245
172
175
lb/ft3
66
55
56
lb/gal
8.82
7.35
7.49
.81
730
220
74
9.89
.84
800
220
75
10.03
.518
.503
42
160
495
95
55
46
7.35
6.15
.24
.58
.033
.47
.47
.51
.71
62
117
-20
554
675
570
750
78.5
79
845
60
58
56
56
10.50
10.58
112.97
8.02
7.75
7.49
7.49
.18
893
1400
44.6
5.96
.3
.234
1810
652
1638
601
51.2
6.84
.36
.41
1.0
133
965
650
319
212
73.5
54
62.5
9.83
7.22
8.34
Substance
Acetic acid
Alcohol
Benzine
Brine
(25% NACI)
Caustic soda
(18% NaOH)
Dowtherm A
(at 450F)
Ether
Freon 12
(Saturated liquid)
Glycerine
Mercury
Oil, cotton seed
Oil, olive
Oil, petroleum
Paraffin, melted
Potassium
(at 1000F)
Sodium
(at 1000F)
Sulfur, melted
Therminol FR-1
(at 450F)
Turpentine
Water
Source: Chromalox (5)
61
Density
Industrial Applications
Properties of Liquids
Industrial Applications
Substance
Specific
Heat at Constant
Pressure
Btu/lb/F
Density at
70F and
Atmospheric
Pressure lb/ft3
Acetylene
.35
Air
.237
Ammonia
.520
Argon
.124
Carbon dioxide
.203
Carbon monoxide
.243
Chlorine
.125
Ethylene
.4
Helium
1.25
Hydrogen
3.41
Methane
.6
Methyl chloride
.24
Nitric Oxide
.231
Nitrogen
.245
Oxygen
.218
Sulphur dioxide
.155
Water vapor (212F) .451
.073
.08
.048
.1037
.123
.078
.2
.0728
.0104
.0056
.0447
.1309
.0779
.078
.09
.179
.0372
62
Thermal
Conductivity at 32F and
Atmospheric Pressure
Btu/hr/ft2/F
.0108
.014
.0175
.00912
.0085
.0135
.0043
.0101
.0802
.0917
.0175
.0053
.0138
.014
.0142
.005
.0145
Cost/kW
Fuel
Tank?
Diesel
$250
24-hour
Propane
Tank not
furnished
Not
required
Protection
Time
Size
Range
Uninterruptible
Power System
(UPS): Battery
(long term)
5-10 minutes
typical
protection
with longer
battery times
available
650 VA
to
750 kVA
63
Comments
Provides for proper operation
of protected equipment for
outages up to several minutes
or seamless transfer to
generator or orderly shutdown
of protected equipment before
the battery power expires.
Considerations
Solution
Type
Protection
Time
UPS: Flywheel
UPS: Battery
(short-term)
Dynamic Sag
Corrector
Size
Range
N/A
64
Comments
Type
Potential
In SE Cost/kW
Fuel Cell
High
Microturbine
Cost/kWh
Comments
$5000
Cost of
fuel/efficiency
Works by converting
natural gas to hydrogen.
High
$1000
(standard);
$1400
(combined
heat and
power).
Must evaluate
system
efficiency.
At 2002 gas
prices, about
$0.10/kWh.
Windpower
Low
Active
Solar
Low
$1000-1200
(13%
of energy
delivered)
Waste-to
Energy
MedHigh
65
Industrial application.
Requires extensive
permitting and design.
Best applications have
fuel with no retail value
and steam requirements
in plant.
Electrical Distribution
Electrical Distribution
For single-phase light and power
branch circuits.
Transformer
secondary
Single-phase, 3-wire
For three-phase power circuits and singlephase light and power branch circuits.
Three-phase, 4-wire delta with one phase
center tapped and grounded. (Threephase, 3-wire delta for power loads is used
with a separate single phase supply for
lighting.
For three-phase power circuits and single-phase light and power branch
circuits.
Three-phase, 4-wire wye (or star) with grounded neutral rated 120/208 volts.
For three-phase power circuits and lighting circuits using 277-volt ballasts.
120-volt lighting and receptacle loads are fed from this system through singlephase transformers rated 480/-120 240 volts or three-phase transformers
rated 480/120-208 volts.
Three-phase, 4-wire wye (or star) with grounded neutral rated 277/480 volts.
66
To Find
Amperes when
Horsepower
is known
Direct
Current
ALTERNATING CURRENT
Single Phase
Three Phase
Hp. x 746
E x Eff. x P.F.
Hp. x 746
1.73 x E x Eff. x P.F.
Amperes when
kW x 1000
Kilowatts is known
E
kW x 1000
E x P.F.
kW x 1000
1.73 x E x P.F.
Amperes when
kVa is known
kVA x 1000
E
kVA x 1000
1.73 x E
I x E x P.F.
1000
I x E x 1.73 x P.F.
1000
IxE
1000
I x E x 1.73
1000
I x E x Eff. X P.F.
746
Kilowatts
Hp. x 746
E x Eff.
IxE
1000
kVA
Horsepower
(output)
I x E x Eff.
746
I = Amperes;
E = Volts;
Eff. = Efficiency expressed as decimal;
kW = Kilowatts;
kVA = Kilovolt-amperes;
Hp = Horsepower
90%
-19%
-11/2%
-2 Points
+11%
-10%
+11%
-Slight
-19%
67
% of Rated Voltage
110%
120%
+21%
+44%
+1%
+1.5%
+1/2 Point
+1 Point
-7%
-.11%
+10%
+.25%
-6%
9%
+Slight
+Noticeable
+21%
+44%
Electrical Distribution
Electrical Distribution
Motor Wattages
1/6 hp = 250 W
1/4 hp = 350 W
1/3 hp = 460 W
1/2 hp = 680 W
3/4 hp = 980 W
1 hp = 1200 W
E2
R
E
R
ExI
W x R
I2 x R
W
I
W
I2
IxR
68
W
E
E2
W
W
R
E
I
kW
1
2
3
4
5
6
7
8
9
10
15
20
25
30
35
40
45
50
120V
10
8.3
16.7
25.0
33.3
41.7
50.0
58.3
66.6
75.0
83.3
125.0
166.6
208.3
250.0
291.7
333.3
375.0
416.6
10
4.8
9.6
14.4
19.2
24.0
28.9
33.7
38.5
43.5
48.1
72.1
96.2
120.2
144.3
168.4
192.4
216.5
240.5
208V
30
2.8
5.5
8.3
11.1
13.9
16.6
19.4
22.2
24.9
27.7
41.6
55.4
69.3
83.1
97.0
110.8
124.7
138.5
10
4.2
8.3
12.5
16.6
20.8
25.0
29.1
33.3
37.4
41.6
62.4
83.2
104.0
124.8
145.6
166.4
187.2
208.0
240V
30
2.4
4.8
7.2
9.6
12.0
14.4
16.8
19.2
21.6
24.0
36.0
48.0
60.0
72.0
84.0
96.0
108.0
120.0
BTUHkWAmperes Chart
Electrical Distribution
BTUH
3,413
6,826
10,239
13,652
17,065
20,478
23,891
27,304
30,717
34,130
51,195
68,260
85,325
102,390
119,455
136,520
153,585
170,650
277V
10
3.6
7.2
10.8
14.4
18.1
21.7
25.3
28.9
32.5
36.1
54.2
72.2
90.3
108.3
126.4
144.4
162.5
180.5
10
2.1
4.2
6.2
8.3
10.4
12.5
14.6
16.6
18.7
20.8
31.2
41.6
52.0
62.4
72.8
83.2
93.6
104.0
480V
30
1.2
2.4
3.6
4.8
6.0
7.2
8.4
9.6
10.8
12.0
18.6
24.0
30.0
36.0
42.0
48.0
54.0
60.0
69
Electrical Distribution
120/240V, single-phase,
three-wire
167
1000
2500
70
Provided by
Comments/Restrictions
Overhead Service
Conductors
Georgia Power
From transformer to
customers weatherhead
Single-phase
underground
service conductors
Georgia Power
Three-phase
underground service
from padmounted
transformers
Customer
Three-phase
underground service
from overhead
transformers
Georgia Power
71
Electrical Distribution
Electrical Distribution
Item
Provided by
Comments/Restrictions
Three-phase
underground service
from overhead
transformers
Customer
Service conductor
connections in
padmounted
transformers, at
weatherheads, and
at metering equipment
Georgia Power
72
Type of Service
Who Limits
Starting Voltage
Drop
Single Phase
Georgia Power
Comments
Responsible for both customer
side and system side
Three-Phase
Customer
Other
Available fault current depends on the size transformer and that
transformers impedance. Register your project at
powerzone@georgiapower.com to get the available fault current for
that location.
Consult Georgia Power Companys current Electrical Service and
Metering Installations for detailed information on metering and service
installation requirements.
73
Electrical Distribution
Motor Starting
Miscellaneous
Diversity Factors for EFLH calculations
Miscellaneous
Equipment
Compressors
(air conditioning)
Lighting, interior
0.9
Lighting, exterior
Space heating
0.65
Cooking
Water heating
0.5
Refrigeration
0.8
Miscellaneous
0.25
This chart can be used to calculate the demand charges for various types of
equipment. Demand seen by meter = Rated kW * Diversity.
Remember to apply only during the months that the equipment would run!
74
Noise
Design Criteria for Room Loudness
Sones
2.0 to 6
2.0 to 6
1.5 to 5
3.0 to 9
4.0 to 12
2.0 to 6
1.7 to 5
2.5 to 8
4.0 to 12
6.0 to 18
2.0 to 6
4.0 to 12
5.0 to 15
1.7 to 5
2.5 to 8
4.0 to 12
2.5 to 8
4.0 to 12
4.0 to 12
1.0 to 3
1.5 to 5
2.0 to 6
Room Type
Sones
4 to 12
3 to 9
7 to 21
4 to 12
4 to 12
Manufacturing areas
Heavy machinery
Foundries
Light machinery
Assembly lines
Machine shops
Plating shops
Punch press shops
Tool maintenance
Foremans office
General storage
25 to 60
20 to 60
12 to 36
12 to 36
15 to 50
20 to 50
50 to 60
7 to 21
50 to 15
10 to 30
Offices
Executive
Supervisor
General open offices
Tabulation/computation
Drafting
Professional offices
Conference rooms
Board of Directors
Halls and corridors
2 to 6
3 to 9
4 to 12
6 to 18
4 to 12
3 to 9
1.7 to 5
1 to 3
5 to 15
Note: Values shown above are room loudness in sones and are not fan sone ratings.
For additional detail see AMCA publication 302 Application of Sone Rating.
75
Miscellaneous
Room Type
Auditoriums
Concert and opera halls
Stage theaters
Movie theaters
Semi-outdoor
amphitheaters
Lecture halls
Multi-purpose
Courtrooms
Auditorium lobbies
TV audience studios
Noise
Design Criteria for Room Loudness (cont.)
Room Type
Hotels
Lobbies
Banquet rooms
Ballrooms
Individual rooms/suites
Kitchens and laundries
Halls and corridors
Garages
Sones
4.0 to 12
8.0 to 24
3.0 to 9
2.0 to 6
7.0 to 12
4.0 to 12
6.0 to 18
Miscellaneous
Residences
Two & three family units
Apartment houses
Private homes (urban)
Private homes
(rural and suburban
1.3 to 4
Restaurants
Restaurants
Cafeterias
Cocktail lounges
Social clubs
Night clubs
Banquet room
4 to 12
6 to 8
5 to 15
3 to 9
4 to 12
8 to 24
Miscellaneous
Reception rooms
Washrooms and toilets
Studios for sound
reproduction
Other studios
3 to 9
3 to 9
3 to 9
Room Type
Public buildings
Museums
Planetariums
Post offices
Courthouses
Public libraries
Banks
Lobbies and corridors
Retail stores
Supermarkets
Department stores
(main floor)
Department stores
(upper floor)
Small retail stores
Clothing stores
Sones
3 to 9
2 to 6
4 to 12
4 to 12
2 to 6
4 to 12
4 to 12
7 to 21
6 to 18
4 to 12
6 to 18
4 to 12
3 to 9
5 to 15
1 to 3
4 to 12
Note: Values shown above are room loudness in sones and are not fan sone ratings.
For additional detail see AMCA publication 302 Application of Sone Rating.
76
Copyright 1972, American Society of Heating, Refrigeration and Air-Conditioning Engineers, Inc.
www.ashrae.org. Reprinted by permission from 1972 ASHRAE Handbook Fundamentals.
77
Miscellaneous
MAY
19
8
3
1
0
0
5
1
0
46
62
52
26
15
50/54
45/49
40/44
35/39
30/34
57
47
30
15
7
3
32
94
59
30
75/79
70/74
65/69
60/64
55/59
09
to
16
4 1
33 13
0 53 28
01
to
08
25
9
3
106
141
176
100
52
5
46
81
48
44
40
66
64
62
58
53
70
69
67
M
Total C
17 Obsn W
to
B
24
Obsn
Hour Gp
100/104
95/99
90/94
85/89
80/84
Temperature
Range
1
0
31
93
82
23
5
0
5
01
to
08
1
0
50 62 143
28 64 185
11 28 121
1 4 28
1 1
7
0
0
4 1
5
29 10 39
52 25 77
65 44 114
09
to
16
01
to
08
1 0
1
5 1
6
30 10 40
0 61 30 91
5 81 57 143
09
to
16
49
44
72
70
66
60
72
74
74
74
73
M
Total C
17 Obsn W
to
B
24
JULY
Obsn
Hour Gp
69 46 51 74 171
68 147 18 69 234
64 46 2 7 55
59
5 0 1
6
55
77
74
74
72
71
M
Total C
17 Obsn W
to
B
24
Obsn
Hour Gp
JUNE
09
to
16
47 42 76 165
133 19 59 211
54 3 11 68
10 0 1 11
0
0
0
0
6 1
7
30 9 39
72 33 105
3 76 58 137
01
to
08
71
69
65
60
56
76
74
74
73
72
M
Total C
17 Obsn W
to
B
24
Obsn
Hour Gp
AUGUST
09
to
16
6
1
0
8
72
82
49
22
57
43
21
14
2
2
11
42
91
1
0
8
1
0
53 118
71 186
40 143
23 86
6 30
2 0
9 2
31 11
0 60 31
01
to
08
49
45
42
68
67
63
59
54
72
71
71
70
M
Total C
17 Obsn W
to
B
24
Obsn
Hour Gp
SEPTEMBER
51
28
14
7
2
1
8
28
51
60
01
to
08
0
1
4
20
87
43
20
8
2
14 57
34 94
54 135
59 149
40 123
0
1
4
12 24
4 11
2 4
0 1
0
42
52
53
39
23
0
1
3
16
09
to
16
48
43
39
33
29
64
63
60
57
52
74
73
70
68
M
Total C
17 Obsn W
to
B
24
Obsn
Hour Gp
OCTOBER
Mean Frequency of Occurrence of Dry Bulb Temperature (degrees F.) with Mean Coincident Wet Bulb (MCWB)
Temperature (degrees F.) for Each Dry Bulb Temperature Range
ATLANTA/HARTSFIELD, GEORGIA
Lat. 33 39N
Long. 84 26W
Elev. 1,010 ft.
Miscellaneous
78
79
12
3
2
0
0
25 23
21 13
14 3
10 2
6 0
7
2
1
1
0
11
3
1
0
0
1
41
18
5
3
0
1
0
5
18
47
69
9
4
3
0
0
24
20
15
11
6
0 0
0 -3
46
17
9
4
0
15
7
3
2
1
5
2
1
0
0
97
106
108
87
53
2
11
28
52
82
47
42
38
34
29
63
60
57
55
51
38
44
48
34
25
0
5
16
30
6 26 24 5
2 11 19 1
2 6 15 1
0 2 11 0
1 6
37
37
35
25
14
64
2 0
63
8 3
60 2 16 10
57 7 25 20
53 17 32 33
Miscellaneous
0 0
0 0
24 28 9
20 9 4
15 5 1
11 3 1
5 0 0
3
0
1
0
0/4
-5/-1
1
0
0
0
0
FEBRUARY
34 89 47 26 34
39 106 43 32 37
43 117 38 43 30
40 123 34 41 21
28 91 29 29 10
0
4 1
11 5
19 19
29 23
8
3
1
0
0
60
60 2
57 9
52 17
25/29
20/24
15/19
10/14
5/9
3
19
47
61
34 38 41 113 47 17 36 33 86 47 21 34
45 30 42 117 42 29 44 41 114 42 25 42
44 20 30 94 38 39 44 53 136 38 36 38
35 9 16 60 33 55 29 37 121 34 46 37
20 4 7 31 29 43 19 25 87 29 45 18
64
60
3 0
59 1 13 5
56 9 22 16
51 13 26 22
50/54
45/49
40/44
35/39
30/34
1 6
5 25
17 54
35 92
43 111
5
20
32
39
40
75/79
70/74
65/69
60/64
55/59
0
5
18
28
1 0
08 16 24
100/104
95/99
90/94
85/89
80/84
JANUARY
MARCH
APRIL
44
37
30
15
6
4
9
24
34
42
1 3
0 1
0
0
40
34
21
12
6
9
18
27
34
45
9
2
1
0
122
115
99
61
37
13
27
56
84
117
25
20
16
11
47
42
38
33
29
62
59
57
54
50
38
41
43
40
29
20
36
48
48
38
58
79
113
143
121
62
61
59
56
52
136
487
423
311
276
213
200
158
108
57
353
301
262
248
234
241
222
201
135
80
350
413
301
286
263
709
665
608
471
303
839
1201
986
845
773
47
42
38
34
29
69
67
62
57
52
1
0
0
0
1
0
1
-3
79 23 32 134 24
33 8 10 51 20
13 3 7 23 15
7 2 0
9 11
1 0 0
1 6
42 17 22 81 46 255
31 9 14 54 42 243
22 3 6 31 38 249
10 0 1 11 34 228
2
2 29 166
2
22
55
54
M
Total C
Obsn W
B
1 73
20 74
135 74
367 72
612 70
ANNUAL TOTAL
Obsn
Obsn
M Obsn
M Obsn
M Obsn
M Obsn
M
Hour Gp Total C Hour Gp Total C Hour Gp Total C Hour Gp Total C Hour Gp Total C Hour Gp
01 09 17 Obsn W 01 09 17 Obsn W 01 09 17 Obsn W 01 09 17 Obsn W 01 09 17 Obsn W 01 09 17
to to to
to to to
to to to
to to to
to to to
to to to
B 08 16 24
B 08 16 24
B 08 16 24
B 08 16 24
B 08 16 24
08 16 24
1 0
17 3
103 2
2 0 2 64 0 254 113
1 67
1 0 1 64
17 7 24 64 13 370 229
M
C
W
B
NOVEMBER DECEMBER
Obsn
Temp- Hour
Gp Total
erature 01 09 17
Obsn
to
to
to
Range
Albany
Athens
Atlanta
Augusta
Brunswick
Columbus,
Metro Airport
Macon
Marietta,
Dobbins AFB
Rome
Savannah
Valdosta,
Regional
Airport
Waycross
Location
94
76
93 75
91 74
91 76
92 76
78
78
79
80
76
74
76
76
91
90
90
90
78
77
78
79
78
76
96
94
93
94
91
88
74
77
77
92 75
89 74
96
95
95
75
74
79
77
94
91
76
74
90
89
89
89
89
87
77 89
76 88
78 87
78 88
77 88
75 86
MDB
88
86
85
88
87
87
96
94
WB
78
76
75
77
79
77
WB MDB WB
79 90 78
78 89 77
77 88 76
79 91 78
81 89 80
79 89 78
MDB
89
87
87
89
88
88
Evaporation WB/MDB
0.4%
1%
2%
Cooling DB/MWB
0.4%
1%
2%
HR
141
133
133
135
147
139
MDB
83
82
82
84
86
82
75 134 84
75 134 83
77 139 84
77 144 83
76 136 83
74 134 82
DP
77
75
74
76
78
76
HR
136
129
128
130
144
134
MDB
82
81
81
83
85
82
75 130 83
74 130 83
76 135 83
76 139 82
75 132 82
73 130 81
DP
76
74
73
75
78
75
HR
133
125
124
127
141
130
MDB
81
80
80
82
84
81
19.8
18.4
17.3
20.2
14.4
18.0
Range
of DB
74 127 83 20.3
73 127 83 20.7
75 132 82 17.5
76 136 82 19.4
74 129 82 19.3
72 123 79 17.1
DP
75
73
72
74
77
74
Dehumidification DP/MDB/HR
0.4%
1%
2%
Miscellaneous
80
Heating
Degree Days
716
563
400
133
37
5
0
0
7
130
394
636
3021
Heating
% Use
24
19
13
3
1
0
0
0
0
4
13
22
100
Cooling
Degree Days (65F)
0
0
12
37
170
329
422
409
247
44
0
0
1670
Cooling
% Use
0
0
1
2
10
20
25
25
15
2
0
0
100
WINTER
SUMMER
Heating
Degree Days
1835
1611
2279
3122
Cooling
Degree Days (65F)
2289
2487
2217
1601
For more detail on climatic data for selected Georgia cities, refer to Climatic Data Base published
by the Cooperative Committee of GAAIA/Georgia Power Company.
calm
5
10
15
20
25
30
35
40
30
27
16
9
4
0
-2
-4
-6
20
10
-10
-20
-30
-40
-30
-36
-58
-72
-82
-88
-94
-98
-100
-40
-47
-70
-85
-96
-104
-109
-113
-116
10
6
-9
-18
-25
-29
-33
-35
-37
0
-5
-21
-36
-39
-44
-48
-49
-53
81
-10
-15
-33
-45
-53
-59
-63
-67
-69
-20
-26
-46
-58
-67
-74
-79
-82
-85
Miscellaneous
Average
Temp.
42
45
52
62
69
76
79
78
73
62
52
44
61
Formulae
Formulae
82
Geometric Formulae
PLANE
SOLID
Triangle
Area A = 1/2bh
Sum of Angle
Measures
A + B + C = 180
Parallelogram
Area A = bh
Trapezoid
Area A =
1/2h(a + b)
Circle
Area A = r2
Circumference
C = D or 2r
(22/7 and 3.14 are
different
approximations for )
Sphere
Volume V = 4/3r 2
Surface Area S = 4r 2
83
Formulae
Right Triangle
Pythogorean Theorem
a2 + b2 = c2
Cube
Volume: V = s3
Formulae
84
Formulae
Curve Formulae
85
Unit Conversions
Metric and English Measures
Linear Measure
Measure of Volume
Square Measure
Weights
Miscellaneous Data
Conversions
1 Ton Refrigeration. . . . . . . .
1 Btu . . . . . . . . . . . . . . . . . . . .
1 Grain (water) . . . . . . . . . . .
1 Pound. . . . . . . . . . . . . . . . . .
1 Pound (air) . . . . . . . . . . . . .
1 lb./sq. in. . . . . . . . . . . . . . . .
1 atmosphere . . . . . . . . . . . .
1 watt hour. . . . . . . . . . . . . . .
1 kilowatt . . . . . . . . . . . . . . . .
1 Horsepower . . . . . . . . . . . .
1 Boiler H. P.. . . . . . . . . . . . . .
1 Gallon (US) . . . . . . . . . . . . .
1 Cu. Ft. (water). . . . . . . . . . .
=
=
=
=
=
=
=
=
=
=
=
=
=
86
Pressure
87
Conversions
Definitions
Definitions
A.F.U.E.Annual Fuel Utilization Efficiency. The annual seasonal
efficiency which accounts for part load operation, cyclic operation,
standby and flue losses in a fossil fuel heating system.
AMPACITYThe current carrying capacity of a conductor.
BTU(British Thermal Unit). The amount of heat energy required to
raise the temperature of one pound of water, one degree fahrenheit.
BTUH HEAT LOSSthe amount of heat that escapes, from warmer
to colder areas, through walls, ceilings, floors, windows, doors and
by infiltration in one hours time.
CIRCUITA conductor or a system of conductors through which an
electric current flows.
CIRCUIT BREAKER or FUSEA load limiting device that automatically
interrupts an electric circuit if an overload condition occurs.
COOLING TONA measure of cooling capacity equal to 12,000 BTU
per hour.
C.O.P.(Coefficient of Performance). The ratio of the rate of heat
delivered versus the rate of energy input, in consistent units, of a
complete, operating heat pump system under designated operating
conditions.
CYCLEFrequency of alternating current expressed in hertz. 60
cycles per second = 60 hertz.
DEGREE DAYA unit that represents one degree of declination from
a given point (as 65F) in the mean outdoor temperature of one day
and is often used in estimating fuel requirements of buildings.
E.E.R.Energy Efficiency Ratio. Used in the efficiency rating of room
and central air conditioners. E.E.R. = BTU watts.
88
89
Definitions
Definitions
90
91
Definitions
Southern Company
http://www.southerncompany.com
Georgia Public Service Commission
http://www.psc.state.ga.us/
U.S. Green Building Council (LEED)
http://www.usgbc.org/
U.S. Dept. of Energy (EREN)
http://www.eren.doe.gov/
ASHRAE
http://www.ashrae.org
Illuminating Engineers Society
http://www.iesna.org
AIA, Georgia Chapter
http://www.aiaga.org
Air Conditioning and Refrigeration Institute
http://www.ari.org
American Council of Engineering Companies, Georgia
http://www.acecga.org
The Georgia Engineer
http://www.thegeorgiaengineer.org
92