DIVISION 1 GENERAL REQUIREMENTS

S.No.

Item description

Unit

Qty.

Rate

DIVISION 1 GENERAL REQUIREMENTS


GENERAL REQUIREMENTS
The Tendered shall include the costs associated with
requirements mentioned hereunder

To Collection Kd

Amount
Kd
Fils

DIVISION 2 SITE WORK


S.No.

Item description

Unit

Qty.

Rate

DIVISION 2 SITE WORK


Excavation including levelling, grading,
ramming, and removing surplus excavated
materials off site.
A excavation in all kinds of soil for foundation from(-9.25) Level m
include trenches, etc up to any depth as per DWGS& specs
including disposal of surplus materials from site o public dump
yards to the satisfaction of engineer
B

Design, furnishing and installation of shoring works including MR


sheet piling as necessary to protect workmen, banks, adjacent
paving, structures and utilities, bracing and sheeting shall be as
excavations are backfilled in a manner to prevent caving
(provisional and remeasured as per site condition )

5910

30

To Collection Kd

Amount
Kd
Fils

DIVISION 2 EXTERNAL WORK


S.No.

Item description

Unit

Qty.

Rate

EXTERNAL WORK
The following items to be priced as provisional
Remeasured as per site condition
cover the supply and installation as per tender
drawings :
A Curb stones for the sidewalks and roads to be
supplied by Kuwait National Industries

and

MR

B Interlock tiles to be supplied by Kuwait


m
National Industries. 6cm thick for side walks 8cm thick for
drive through decorative colored tiles.

To Collection Kd

Amount
Kd
Fils

DIVISION 3 CONCRETE
S.No.

Item description

Unit

Qty.

54

27

Reinforced insitu concrete having grade 350 Kg/cm using


SRC including formwork, curing, etc.
as per drawings.
C Reinforced insitu concrete for raft SRC Grade K 350 with m
sulphat resistance cement,under N.G.L. including, fair face,
formwork water proofing with approved bitumen paint in three
coat, finishing, and vibrating etc all as per drawings.

315

DIVISION 3 CONCRETE
Plain insitu concrete having grade K 150 Kg/cm
using SRC including formwork, curing, etc.
as per drawings.
A 100 mm thick blinding concrete under Raft all as per drawings
B 50 mm thick sand cement protection screed over membrane
insulation

Rate

Reinforced insitu concrete Basement 2 and Basement 1


external perimeter retaining walls
SRC Grade K 350 including formwork,
finishing, vibrating etc all as per drawings.
D Basement retaining wall 250mm thick

233

Reinforced insitu concrete having grade K 350 using


Kg/cm OPC including formwork, curing, etc. .as per
drawings.
E Reinforced insitu concrete solid slabs,
OPC Grade K 350 including formwork,
finishing, vibrating etc all as per drawings.
m
150 mm thick
m
160 mm thick
m
180 mm thick

245
10
7

Reinforced insitu concrete for swimming pool slab and m


walls,OPC Grade K 350 including formwork,finishing,
vibrating etc all as per drawings.

25

F Reinforced insitu concrete Hordi Slabs having grade K300 OPC


R1 600 mm depth

G Reinforced insitu concrete beams OPC Grade K350 including


formwork, finishing, vibrating etc all as per drawings.

m2

440

395

To Collection Kd

Amount
Kd
Fils

DIVISION 3 CONCRETE
Item description
S.No.

Unit

Qty.

H Reinforced insitu concrete columns OPC


Grade K 400 including formwork, finishing,
vibrating etc all as per drawings( iclude parapet column).

180

Reinforced insitu concrete Elevator Walls OPC


Grade K 350 including formwork, finishing,
vibrating etc all as per drawings( iclude parapet column).

14

Reinforced insitu stairs steps, landings, slabs, OPC Grade K 350 m


including formwork, finishing, vibrating etc all as per drawings.

30

Rate

DIVISION 3 CONCRETE

To Collection Kd

Amount
Kd
Fils

DIVISION 7 - THERMAL AND MOISTURE PROT.


Item description
S.No.

Unit

Qty.

Rate Amount
Kd

DIVISION 7 - THERMAL AND MOISTURE PROT.


Guarantee all waterproofing works for a period of
ten years from the date of substantial completion.
The guarantee to be in the form of a Bankers
Guarantee equal to(
) K.D.

Water proofing for basement walls and rafts including curing and

M2

1460

Protected Membrane Roofing to all Roofs including


M2
400mmx400mmx40mm thick plain concrete tiles with loose
gravel measurement in plan only. VL. Including.
- Over Fabric Filter
- Over 12mm Protection Board
- Over 4mm thick waterproofing membrane 2
Layers
- Over 20mm thick min. leveling sand and cement
screed
- Over 50mm thick (minimum) light weight
concrete in slope
- Over 250micron polyethylene sheet
- Over 75mm thick extruded polystyrene insulation
Including all fillets, sealed upturns, metal flashing
and loose gravel all around perimeter and up- Stands.

590

filling all honeycomps, holes, etc and to apply Two layers of

approved membrane material.

C Supply and Applied Waterproofing to wet


areas, kitchens, toilets, all horizontal surfaces
designated, including vertical application to a
height of 100cms in tow layers. membrane
as per requirements including Foam concrete

M2

451

D Supply and Applied Waterproofing to Swimming Pool for


horizontal and vertical surfaces as per drawings and
specifications

M2

60

To Collection Kd

Fils

Description

AMOUNT
KD

SUMMARY
CIVIL /1
CIVIL /2
CIVIL /3
CIVIL /4
CIVIL /5
CIVIL /6
CIVIL /7
CIVIL /8
CIVIL /9
CIVIL /10
CIVIL /11
CIVIL /12
CIVIL /13
CIVIL /14
CIVIL /15
CIVIL /16
CIVIL /17

To Grand Summary

FILS