Measuring Task Clamp-On Flow


Flow measurement of river water to balance pump loads Measurement of River
Nominal diameters: 6 x 30” steel pipes Water at a Pump Station
All transducers are submerged for 6 - 8 months per year

Instruments Used Customer


2 FLUXUS® F 7807 with 6 pairs of M3L8 transducers
Advantages
• Reliable non-invasive measurement
• Wide flow range
Selling Points
• Long-term submersion of transducers Bureau of Reclamation,
• Long signal cables between transducers (under water) and transmitters American River Pump Station,
• Accurate flow measurement with 2-path reflection mode in less-than-ideal Place County, CA
conditions
The Bureau of Reclamation is an
Description agency under the U.S. Department of
the Interior and oversees water
resource management. Established in
1902, the Bureau of Reclamation has
constructed since then more than 600
dams and reservoirs including Hoover
Dam on the Colorado River.
Today, the Bureau of Reclamation is
the largest wholesaler of water in the
country. It brings water to more than
31 million people and provides one
out of five Western farmers (140,000)
with irrigation water for 10 million
The American River flowing out of the California Sierra Nevada mountains
acres of farmland that produce 60%
and into the Sacramento River is dammed near Auburn. A reservoir is thus
of the nation's vegetables and 25% of
created to provide water to the surrounding cities. The water is pumped out its fruits and nuts. Reclamation is also
of the reservoir uphill to water treatment plants. For this purpose, it is the second largest producer of
collected in a specially constructed storage basin. Six pumps move the water hydroelectric power in the western
out of this basin thru 6 x 30” stainless steel pipes. Except during the summer United States.
months (July - September), the river volume is such that it fills the newly
created water storage basin to various levels of capacities – with the 6
pipelines almost always submerged in water.
Each of the submerged six transducer sets is connected with 70 feet of cable
to junction boxes mounted above the 500-year flood level. From there,
another 170 feet of cable is needed to cover the distance to the central
control building. One 4-channel and one 2-channel 7807 transmitters are
used to drive the transducers and process the signals, resulting in six analog
and flow proportional signals. Each section of pipe available for the
transducer installations is only 48 inches long (between a cement wall and
the pipe opening) – this posing a challenge for well developed flow profiles.
The transducer signal is strong enough to work in reflection (or 2-path) mode,
thus helping to compensate for possible flow profile irregularities. The
accuracy is high enough to assure the customer proper load balancing
between all six pumps.

FLUXUS®, WaveInjector®, and PIOX® are protected trademarks of FLEXIM GmbH. Copying and distribution allowed only with the written permission of
FLEXIM GmbH. The copyright of this report, its components, content and pictures is owned by FLEXIM or by third parties. All rights reserved. The aim of this
application report is solely to give general information about the application. It does not assure the suitability of the instrument for a specific purpose.
AR-200716-BoR-EN

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963

Anda mungkin juga menyukai