Anda di halaman 1dari 2

VerXL5

Ver8.01 - (01/07/2014) TSTD

3.00

1310nm

1550nm

1625nm

Testing completed from cu


ween going from customer to exchange to complete bi-dir test

0.00

Testing completed from cus


ween going from customer to exchange to complete bi-dir test

XL5V601IL

Telstra

OPTICAL FIBRE CABLE TESTS


STANDARD FIBRE CABLE TEST

INSERTION LOSS (IL) AND OTDR END TO END LINK LOSS (LL) TABLES
13003803.DALLDALL.DALL3909.F263

WorkBookID :Route:

YY-DR-HF-B113

Section

FDALL3909 YY - FDALL3909 B113

ServiceNo

N2727628Q

Terminal

"A"
"B"

Date :

Seperable Portion (SP) No: 13003803


Work Order (WO) :
Project:

ESA

Sheath ID

OTDR

Light Source

Power Meter

Operator

DALL

FDALL3909YY

8652

10685

10685

S.CRAWFORD

DALL

FDALL3909B113

8652

10685

10685

Length (L) km =

1.064

Sheath Fibre No.

1310nm

A end

B end

Ref

263

0.00

Meas

InputBA
1310nm
A-B

1310nm
Ref

Meas

IL

B-A

Avg

0.00

B -A

1310nm

IL-LL

LL

1310nm

0.64
1.69
0.37

CALC MAX INSERTION LOSS (IL) = ( F*L ) + ( S*N ) + ( ACL*C ) + 0.3

OTDR LINK LOSS

A- B

1550nm
Ref

Meas

InputBA
1550nm
A-B

0.00
0.89

Cursor Length (CL)


*Default=OTDR Length(kM)

1550nm
Ref

Meas

IL

B-A

Avg

318208040.xlsx

MIN IL =
MAX IL=

1550nm

L =OTDR Optical Length

Enter Comments in Yellow Area


Do Not Add individual Cell Comments to worksheets.

C = Number of connectors

N = Number of splices

OptiTap=

0.40

C = Number of connectors

Meas

InputBA
1625nm
A-B

Total ODFs=

1625nm
Ref

Meas

IL

B-A

16.70

0.30
0.25

CL=Cursorseperation Length

OTDR LINK LOSS

A- B

B -A

1625nm

IL-LL

Check

LL

1625nm

P/F

0.50
1.59
0.27
MIN IL =
MAX IL=

ODF=

Avg

0.00

1.00
Limit

1x32 Splitter=

0.62

1625nm
Ref

0.00
0.72

ACL=Allowable connector loss (dB) =


Optitip=

Form No: Telstra FibreVer6 Insertion Loss

IL-LL

LL

Cursor Length (CL)


*Default=OTDR Length(kM)

NOTE(1) : Maximum Insertion Loss for TIE cables is 1.5dB

0.10

1550nm

B -A
0.47

1.52
0.21

MIN IL =
NOTE(1) : Maximum Insertion LossMAX
fo IL=
CALC MAX OTDR END TO END LINK LOSS (LL) = ( F * C L ) + ( 0.1 * ( N-2) ) + 0.3

Testing completed from customer to exchange, in the time between going from customer to exchange to complete bi-dir testing a Telstra tech must have patched the exchange and customer end as we had traffic on fibre.

^^^^^

OTDR LINK LOSS

A- B

Splitter=

InputAB

Total OptiTaps=

0.00

1.00
Limit

F=Fibre Attenuation Co-Efficient (dB/km)


S= Two-way Av splice loss

Thru Connectors = 2

Total Optitips= 0

CALC MAX OTDR END TO END LINK LOSS (LL) = ( F * C L ) + ( 0.1 * ( N-2) ) + 0.3

Comment

S.CRAWFORD

Total Splices = 4

InputAB

Calculated Maximum
F=Fibre Attenuation Co-Efficient (dB/km)

CALC MAX. INSERTION LOSS (IL) = ( F*L ) + ( S*N ) + ( ACL*C ) + 0.3

No of fibres =

InputAB

Sheet :

7/7/2015

Pass

0.79
Cursor Length (CL)
*Default=OTDR Length(kM)

1.00
Limit

0
0

Line
System ID

Ver8.00 - (01/04/2014) Tri-Wave Optic Fibre Workbook, Copyright 2014 R.M.Delaney

VerXL5

Telstra

OPTICAL FIBRE CABLE TESTS Joint Location and Cable Details


Route:
Section

YY-DR-HF-B113
FDALL3909 YY - FDALL3909 B113

Total Events

EXTRA's

MEASURED LOCATION DETAILS


Event No

1
2
3
4
5
6

Event ID

Splice No

CONN
YY
DR
HF
B113
CONN

DALL
FDALL3909YY
Event1
CONN

Sheath A

"B" End

DALL

Sheath B

FDALL3909YY
FDALL3909B113

Test By

S.CRAWFORD

and

S.CRAWFORD

Date :

7/7/2015

/2
13003803.DALLDALL.DALL3909.F263
Job No:
0

Project :

CABLE DETAILS
Distance from Distance from
Total Distance Address *** maximum of 42 characters
A
B

1
2
3
4
-

Event2
YY
0.005
PIGTAIL
F263

"A" End

DALL

0.000
0.005
0.205
0.603
1.059
1.064

1.064
1.059
0.859
0.461
0.005
0.000

Event3
DR
0.206
288AFNPEHJ
F263

Event4
HF
0.289
288AFNPEHJ
F263

Section
CONN-YY
YY-DR
DR-HF
HF-B113
B113-CONN

1.064 RACK 4/4A/11_ 4 DALLEY ST, SYDNEY


1.064 RACK 4/4A/11_ 4 DALLEY ST, SYDNEY
1.064 PITT ST, TUNNEL, E41-38
1.064 50 PHILLIP ST, SYDNEY
1.064 44-58 YOUNG ST, SYDNEY
1.064 44-58 YOUNG ST, SYDNEY

Event5
B113
0.230
36AFNPEHJ
F23

Cable Batch No

Cable Type
PIGTAIL
288AFNPEHJ
288AFNPEHJ
36AFNPEHJ
PIGTAIL

Fibres Used
F263
F263
F263
F23
F1

Survey Length
0.005
0.206
0.289
0.230
0.005

DALL
FDALL3909B113
Event6
CONN
0.005
PIGTAIL
F1

Form No: Telstra FibreVer6 Line Diagram

Anda mungkin juga menyukai