Products and Services


Combined expertise and excellence in heat transfer
GEA Searle is one of the longest established and principal manufacturers of heat exchange products for the refrigeration and air
conditioning industry in Europe. Established in 1921, GEA Searle boasts a comprehensive range of Condensers, Dry coolers, Unit
coolers and Condensing units. GEA Searle products are utilised across many industries. Applications include supermarket cabinets
and cold rooms, large scale food freezing plants, food storage and distribution centres, beer cellars, industrial process cooling,
combined heat and power installations and air-conditioning equipment for hospitals, offices, schools and museums. In order to
guarantee the continued excellence of our products in terms of innovation, design and performance, GEA Searle has invested in
one of the most comprehensive Research & Development facilities in the European refrigeration industry. GEA Searle also undertakes special projects on behalf of other manufacturers, customers and end-users.

Support, Replacement Parts & Spares


Trained staff will advise you through every step of the selection process, our customer service continues past the product delivery, and we are always on hand to advise on any issues.
GEA Searle can supply spare or replacement parts for any of our existing product ranges. Many parts
are available for discontinued ranges. Manufacturing plants: GEA Searle products (UK), GEA ErgSpirale and GEA Polska products, GEA Kba (Germany)
Air Coolers
With the increasing importance of energy efficiency, the new GEA Searle coolers utilise fansets which
offer significant energy savings over traditional motor assemblies. The KEC & TEC coolers have high
efficiency EC fans as standard across the range. All our commercial unit coolers have white powder
coated galvanised steel casing (JG and NS are aluminum) and are available in high or low temperature versions, with CO2 and glycol circuiting options. Many of the models in the commercial unit
cooler ranges are available ex-stock from your local distributor, with backup stocks held at the UK
manufacturing plant centre.
Air Cooled Condensers
Our range has literally 1000s of models, created through a modular design and variety of fan sizes,
offering a greater choice to match your requirements. Our condensers can meet even the most
stringent noise restrictions using the latest 6, 8 & 12 pole fansets. In addition, we offer EC technology across the standard range, which offers variable speed control and high efficiency. Due to rising
energy costs, efficiency is becoming a key factor within the industry and is increasingly important on
end-user criteria. Our new units use the latest technology to ensure greater energy efficiency. GEA
Searle has extensive experience in the design of controls either using the GEA Searle controller or
industry standard controllers such as Millennium 2 or RDM.
Dry Air Coolers
The range has literally 1000s of models, created through a modular design and variety of fan sizes,
offering a greater range of solutions to match your requirements. Our Dry Coolers can meet even the
most stringent noise restrictions using the latest 6, 8,12 & 16 pole fansets. In addition, we offer EC
technology across the standard range, which offers full variable speed control.
Condensing Units
GEA Searle Condensing Units are supplied as standard to a high specification with a complete
control package, incorporating: Mains Isolator, Compressor Motor Starter/Overloads or MCBs for
single phase models, Fan speed control & anti-cycle timer, Compressor Contactors, Fitted pressure
relief valve (PRV), Compressor Crankcase Heaters GEA Searle units range from the NSQ using scroll
compressors to the NDQ using the latest digital scroll compressors. There are twin compressor variants of the NSQ and NDQ.

ac

.c

om

k
lic
C

.c

re

k e r- s o ft w a

ac

ww

ww

tr

om

to

to

bu

N
O

PD

PD

k e r- s o ft w a

re

F -X C h a n ge

F -X C h a n ge

W
N
O
y
bu
ac

.c

tr

om

to
k
lic
C

k
lic
C

.c

re

k e r- s o ft w a

ac

ww

ww

tr

om

to

bu

N
O

PD

PD

k e r- s o ft w a

re

F -X C h a n ge

F -X C h a n ge

W
N
O
y
bu
k
lic
ac

.c

tr

om

to
.c

re

k
lic
C
k e r- s o ft w a

ac

tr

ww

ww

om

to

bu

N
O

PD

PD

k e r- s o ft w a

re

F -X C h a n ge

F -X C h a n ge

W
N
O
y
bu
ac

.c

tr

k e r- s o ft w a

Products and Services


Combined expertise and excellence in heat transfer
Product Selection Software
This section contains screenshots of selected features of the latest version of the GEA Searle Product
Selection software also avalible for GEA Erg-Spirale, GEA Kba and GEA Polska products. This release retains the familiar interface which our customers tell us they like, but adds a number of new
features requested by customers. The new introductory screen places Searle within the context of
our new parent group, GEA.
The main screen incorporates the traditional layout and appearance of the existing program, but
now includes all product types within one program. The customer can select the type of product by
clicking an icon or selecting from a drop-down list; which ever they find most convenient. The box
to the left of the Select button allows the customer to enter a filter (for example MM for a models
considered).

Introductory Screen

The product specifcation of one or more models is presented in the traditional way. Although not
visible on this screenshot, the specifcation screen allows the customer to select optional extras (by
ticking checkboxes at the bottom of the specifcation). The net price of the unit (including extras
and taking into account customer discounts) is immediately calculated and displayed. A new feature
of this version is that the specifcation can be presented as a PDF file.
The appearance of the specifcation document will be enhanced to include company logos, contact
information and anything else required to create a professional proposal document. The specifcation
document can include one or more specifcation pages and the relevant drawings.

Main Screen

Note: Also in the screenshot that bookmarks in the PDF file allow quick navigation to the relevant
part of a large specifcation document.

Website
Keep up to date with our products and latest news by visiting the website, www.searle.co.uk

Quality and Performance


Eurovent Certifcation

Quality Assured

CE Marking

om

k
lic
C

om

k
lic
C

.c

re

k e r- s o ft w a

ac

ww

ww

tr

to

to

bu

N
O

PD

PD

Specification of selection models

re

F -X C h a n ge

F -X C h a n ge

W
N
O
y
bu
k
lic
tr

ac

.c

om

k
lic
C

.c

re

k e r- s o ft w a

ac

ww

ww

tr

om

to

to

bu

N
O

PD

PD

k e r- s o ft w a

re

For full selection data either refer to the Selection data tables or
use the Searle selection software, either online or via your local
GEA Searle representative.

F -X C h a n ge

F -X C h a n ge

W
N
O
y
bu
ac

.c

tr

k e r- s o ft w a

CO2 Coolers - 75 Bar


AFC Compact Systems
GEA Searle offers an expanded range of CO2 unit coolers for commercial and retail refrigeration applications. The coolers have been optimised to meet the diverse requirements of the developing CO2 system
designs; variables include transcritical, subcritical and standing pressures. GEA Searle have designed a
one size fits all specification to apply to our most popular ranges. The cooler ranges detailed within
this brochure are hybrid versions of our tried and tested TEC, KEC, KMe and DSR coolers. Whilst the coil
technology employed is different the overall dimensions and electrical loadings remain as per our standard (non CO2) ranges.
For more information, please refer to our Selection Software program or selection data tables.
Alternatively a fully interactive version of selection software is available online at www.searle.
co.uk, where it is possible to view all brochures and Installation & Maintenance manuals.

om

k
lic
C

om

k
lic
C

.c

re

k e r- s o ft w a

ac

ww

ww

tr

to

to

bu

N
O

PD

PD

re

F -X C h a n ge

F -X C h a n ge

W
N
O
y
bu
k
lic
ac

.c

.c

tr

re

CO2 Coolers - 75 Bar


AFC Compact Systems

k e r- s o ft w a

om

k
lic
C

ac

ww

ww

tr

om

to

to

bu

N
O

PD

PD

k e r- s o ft w a

re

General range features


GEA Searle offers an expanded range of CO2 unit coolers for commercial and retail refrigeration applications. The coolers have been optimised to meet the diverse requirements of the developing CO2 system
designs; variables include transcritical, subcritical and standing pressures. GEA Searle have designed a
one size fits all specification to apply to our most popular ranges. The cooler ranges detailed within
this brochure are hybrid versions of our tried and tested TEC, KEC, KME and DSR coolers. Whilst the coil
technology employed is different the overall dimensions and electrical loadings remain as per our standard (non CO2) ranges.
Coils
Maximum operating pressure 75 BarG with aluminium fins as standard. Other fin materials and coatings
are available upon request. Flow direction arrows added to connections to reduce on site confusion with
the smaller pipe sizes and single circuit (non distributor) coils.
Defrost
Option for electric coil and tray.

Quality Assurance
GEA Searle is a quality assured under the BSEN ISO 9001 encompassing Performance Testing, Manufacturing Systems and Inspection Procedures. The coolers are covered by Searles full technical support and
24 months warranty.

Blygold Coating (Optional)


GEA Searle specialist coating facility, where a Blygold coating is applied and cured to protect
the finned coils against harsh environmental conditions such as erosion by sand or salt. It provides
a barrier and avoids the risk of electrolytic reactions between the two metals involved. The coating contains aluminium, in order to maintain the thermal performance of the coil, resulting in an
extension of the lifetime, maximum cooling capacity and reduction of energy costs. The coating
is oriented in such a way that it creates a very high chemical resistance at low layer thickness.

The Blygold concept is a revolutionary product created to prevent corrosion which will ultimately
reduce energy costs.

F -X C h a n ge

F -X C h a n ge

W
N
O
y

1-4

1&
3ph

DSC

1-4

1 ph

TEC

1-3

1 ph

k
lic

10

ac

5.7 - 28

0.8 - 15

0.5- 3.4

Designation

KE
Range

KE, KM, DS, TE

CO2

Type

X = Direct Expansion, P = Pump Circulation

Model

Various

Defrost

Blank = No Defrost, L = Electric

30

Factors apply to all CO2 Coolers

Correction Factor (multiplier)

General Notes:

12K D
11 K D
10 K D
9 KDT

1. Capacities shown at SC2 conditions i.e. 8KDT1, -8C evaporation


temperature.
2. Air throws based upon terminal velocity of 0.25m/s.
3. Fan power is total fan power for the unit.

8 KDT
7 KDT
6 KDT
5 KDT

4. HS - High speed, LS - Low speed.


5. Noise levels quoted @3m 45 directivity within free field conditions.
6.

* = Designates units which have a low circuit loading. Refer to your supplier
for selections below -15C evaporating temperature.

o
Evaporating Temperature C

k e r- s o ft w a

100

1.2 - 10.5

Kit

.c

tr

om

to

bu

KMC

Electric Defrost

1 ph

Capacity kW @ 8 KDT1

Standard

1-3

Supply

No fans

Configuration

Models

KEC

EC Fans

.c

om

k
lic
C

Options

re

k e r- s o ft w a

ac

ww

ww

tr

to

bu

N
O

PD

PD

re

F -X C h a n ge

F -X C h a n ge

PD

N
O
y
bu
to
k
lic
tr

ac

.c

.c

re

k
lic
C

k e r- s o ft w a

ac

tr

ww

ww

om

to

bu

N
O

KEC Evaporator range

om

PD

k e r- s o ft w a

re

Direct expansion - CX
Model
K
K
K
K
K
K
K
K
K
K

E
E
E
E
E
E
E
E
E
E

C
C
C
C
C
C
C
C
C
C

X
X
X
X
X
X
X
X
X
X

1
1
2
2
3
3
4
4
5
7

Conn Size

Capacity
kW

Air Vol.
m3 /s

Surface
m2

Int. Vol.
dm3

Weight
AL - kg

inlet

outlet

Air Throw
m

1.26
1.50
1.86
2.40
3.05
3.63
4.40
6.10
7.09
9.04

0.28
0.28
0.29
0.42
0.40
0.58
0.83
0.81
1.25
1.21

5.05
5.05
6.94
6.94
10.41
12.62
12.62
18.94
18.94
28.40

2
2
3
3
4
4
4
6
6
9

29
30
35
35
38
51
51
59
73
83

3/8
3/8
3/8
3/8
3/8
3/8
3/8
1/2
1/2
1/2

5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8

16
16
16
22
22
16
22
22
22
22

Capacity
kW

Air Vol.
m3 /s

Surface
m2

Int. Vol.
dm3

Weight
AL - kg

outlet

Air Throw
m

0.28
0.28
0.29
0.42
0.40
0.58
0.83
0.81
1.25
1.21

5.05
5.05
6.94
6.94
10.41
12.62
12.62
18.94
18.94
28.40

2
2
3
3
4
4
4
6
6
9

29
30
35
35
38
51
51
59
73
83

5/8
5/8
5/8
5/8
5/8
5/8
5/8
7/8
7/8
7/8

16
16
16
22
22
16
22
22
22
22

0
5
0
5
0
5
0
5
5
0

Pump cirulation - CP
Model
K
K
K
K
K
K
K
K
K
K

E
E
E
E
E
E
E
E
E
E

C
C
C
C
C
C
C
C
C
C

P
P
P
P
P
P
P
P
P
P

1
1
2
2
3
3
4
4
5
7

0
5
0
5
0
5
0
5
5
0

1.62
1.85
2.17
2.85
3.51
4.27
5.36
7.00
8.38
10.37

Conn Size
inlet
3/8
3/8
3/8
3/8
3/8
3/8
3/8
5/8
5/8
5/8

Fan & Noise Data


Fan Detail
Model
K
K
K
K
K
K
K
K
K
K

E
E
E
E
E
E
E
E
E
E

C
C
C
C
C
C
C
C
C
C

*
*
*
*
*
*
*
*
*
*

1
1
2
2
3
3
4
4
5
7

Dia
mm
300
300
300
300
300
300
300
300
300
300

Qty
0
5
0
5
0
5
0
5
5
0

1
1
1
1
1
2
2
2
3
3

Speed
rpm
1370
1370
1370
1750
1750
1370
1750
1750
1750
1750

Noise
FLC
A
0.35
0.35
0.35
0.70
0.70
0.35
0.70
0.70
0.70
0.70

Power
W
30
30
30
70
70
60
140
140
210
210

SC
A
0.5
0.5
0.5
1.0
1.0
0.5
1.0
1.0
1.0
1.0

dB(A)
@3m
44
44
44
52
52
47
55
55
57
57

Note: Power per unit currents per motor


Dimensions and Defrost Data
Dimensions
Model
K
K
K
K
K
K
K
K
K
K

Note:

E
E
E
E
E
E
E
E
E
E

C
C
C
C
C
C
C
C
C
C

*
*
*
*
*
*
*
*
*
*

1
1
2
2
3
3
4
4
5
7

0
5
0
5
0
5
0
5
5
0

Defrost

Length
mm

Height
mm

Width
mm

Coil
kW

Tray
kW

726
726
876
876
876
1326
1326
1326
1826
1826

461
461
461
461
461
461
461
461
461
461

524
524
524
524
524
524
524
524
524
524

0.68
0.68
0.92
0.92
0.92
1.60
1.60
1.60
2.40
2.40

0.34
0.34
0.46
0.46
0.46
0.80
0.80
0.80
1.20
1.20

See general notes on page 8 HS = High speed, LS = Low speed

!
W

bu

ac

.c

tr

k e r- s o ft w a

Direct expansion - CX
Model
K
K
K
K
K
K
K

M
M
M
M
M
M
M

C
C
C
C
C
C
C

X
X
X
X
X
X
X

5
6
8
9
1
1
1

0
0
0
5
15
4 0
7 5

Capacity
kW

Air Vol.
m3 /s

Surface
m2

Int. Vol.
dm3

Weight
AL - kg

6.36
7.65
10.08
12.92
15.12
19.53
24.57

0.89
0.96
1.89
1.78
2.83
2.68
3.45

18.26
27.05
24.35
36.52
36.52
54.78
64.92

6
9
8
11
11
17
19

91
120
137
150
181
212
237

Capacity
kW

Air Vol.
m3 /s

Surface
m2

Int. Vol.
dm3

Weight
AL - kg

7.40
8.65
12.02
14.92
18.03
22.49
28.38

0.89
0.96
1.89
1.78
2.83
2.68
3.45

18.26
27.05
24.35
36.52
36.52
54.78
64.92

6
9
8
12
11
17
20

91
120
137
150
181
212
237

Conn Size
outlet

Air Throw
m

5/8
5/8
5/8
5/8
5/8
7/8
7/8

17
19
19
17
19
17
17

inlet

outlet

Air Throw
m

5/8
5/8
5/8
7/8
7/8
7/8
7/8

7/8
7/8
7/8
1 1/8
1 1/8
1 1/8
1 1/8

17
19
19
17
19
17
17

inlet
1/2
1/2
1/2
1/2
1/2
5/8
5/8

Pump cirulation - CP
Model
K
K
K
K
K
K
K

M
M
M
M
M
M
M

C
C
C
C
C
C
C

P
P
P
P
P
P
P

5
6
8
9
1
1
1

0
0
0
5
15
4 0
7 5

Conn Size

Fan & Noise Data


Fan Detail
Model

K
K
K
K
K
K
K

M
M
M
M
M
M
M

C
C
C
C
C
C
C

*
*
*
*
*
*
*

5
6
8
9
1
1
1

0
0
0
5
15
4 0
7 5

Qty

Dia
mm

Speed
rpm

Power
W

1
1
2
2
3
3
4

400
400
400
400
400
400
400

1410
1410
1410
1410
1410
1410
1410

190
190
380
380
570
570
760

230V - 1ph - 50Hz


FLC
A

SC
A
4.5
4.5
4.5
4.5
4.5
4.5
4.5

1.05
1.05
1.05
1.05
1.05
1.05
1.05

Noise

400V - 3ph - 50Hz


FLC
A

SC
A

dB(A)
@3m

0.65
0.65
0.65
0.65
0.65
0.65
0.65

2.75
2.75
2.75
2.75
2.75
2.75
2.75

60
60
63
63
65
65
66

Note: Power per unit currents per motor


Dimensions Defrost Data
Defrost

Dimensions
Model
K
K
K
K
K
K
K

M
M
M
M
M
M
M

Note:

C
C
C
C
C
C
C

*
*
*
*
*
*
*

5
6
8
9
1
1
1

0
0
0
5
15
4 0
7 5

Length
mm

Height
mm

Width
mm

Coil
kW

Tray
kW

1007
1332
1682
1682
2357
2357
2732

575
575
575
575
575
575
575

536
536
536
536
536
536
536

1.59
2.40
3.18
3.18
4.80
4.80
5.64

0.80
1.20
1.59
1.59
2.40
2.40
2.82

See general notes on page 8, High speed, LS = Low speed

om

to

lic

om

k
lic
C

.c

re

k e r- s o ft w a

ac

to

bu

N
O

KMC Evaporator range


ww

ww

tr

F -X C h a n ge

N
O

PD

F -X C h a n ge

PD

11

re

F -X C h a n ge

F -X C h a n ge

PD

N
O
y
bu
to
k
lic
tr

ac

Direct expansion - CX

D
D
D
D
D
D
D
D
D
D

S
S
S
S
S
S
S
S
S
S

C
C
C
C
C
C
C
C
C
C

X
X
X
X
X
X
X
X
X
X

1
2
3
4
5
6
6
8
1
1

Air Vol

Capacity

Model
9
2
6
2
1
2
8
3
0 0
1 6

HS - kW

LS - kW

1.92
2.47
3.60
4.77
5.80
7.02
7.62
9.61
11.17
13.06

1.21
1.52
2.31
2.95
3.78
4.61
5.16
6.00
7.51
8.64

HS - m /s LS - m /s
3

0.31
0.30
0.61
0.59
0.92
0.88
1.22
1.18
1.72
1.56

0.17
0.16
0.34
0.32
0.50
0.49
0.67
0.65
0.98
0.89

.c

.c

re

k
lic
C

k e r- s o ft w a

ac

tr

ww

ww

om

to

bu

N
O

DSC Evaporator range

om

PD

k e r- s o ft w a

re

Air Throw

Conn Size

Surface

Int. Vol

Weight

dm3

AL - kg

inlet

outlet

HS - m

LS - m

5.95
8.93
10.82
16.23
16.23
24.35
21.64
32.46
36.07
54.10

3
3
4
6
5
8
7
10
11
16

58
62
82
90
109
121
139
154
166
189

3/8
3/8
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2

5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8

11
11
12
11
12
11
12
11
11
11

7
7
8
7
8
7
8
7
7
7

Surface

Int. Vol

Weight

Pump cirulation - CP

D
D
D
D
D
D
D
D
D
D

S
S
S
S
S
S
S
S
S
S

C
C
C
C
C
C
C
C
C
C

P
P
P
P
P
P
P
P
P
P

1
2
3
4
5
6
6
8
1
1

9
2
6
2
1
2
8
3
0 0
1 6

Air Vol

Capacity

Model

HS - kW

LS - kW

HS - m3 /s

LS - m3 /s

m2

dm3

AL - kg

2.26
2.78
4.31
5.38
6.74
8.02
8.92
10.81
12.87
14.74

1.41
1.66
2.71
3.23
4.25
5.03
5.78
6.57
8.41
9.34

0.31
0.30
0.61
0.59
0.92
0.88
1.22
1.18
1.72
1.56

0.17
0.16
0.34
0.32
0.50
0.49
0.67
0.65
0.98
0.89

5.95
8.93
10.82
16.23
16.23
24.35
21.64
32.46
36.07
54.10

3
3
4
6
5
8
7
10
11
16

58
62
82
90
109
121
139
154
166
189

Air Throw

Conn Size
inlet

outlet

HS - m

LS - m

3/8
3/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8

5/8
5/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8

11
11
12
11
12
11
12
11
11
11

7
7
8
7
8
7
8
7
7
7

Fan & Noise Data


Fan Detail
Model

D
D
D
D
D
D
D
D
D
D

S
S
S
S
S
S
S
S
S
S

C
C
C
C
C
C
C
C
C
C

*
*
*
*
*
*
*
*
*
*

1
2
3
4
5
6
6
8
1
1

9
2
6
2
1
2
8
3
0 0
1 6

Qty
1
1
2
2
3
3
4
4
4
4

Speed
rpm

Dia
mm
305
305
305
305
305
305
305
305
305
305

HS - High Speed

Noise

LS - Low Speed

HS/LS

Power
W

FLC
A

SC
A

Power
W

FLC
A

SC
A

dB(A)
@3m

dB(A)
@3m

1300/750
1300/750
1300/750
1300/750
1300/750
1300/750
1300/750
1300/750
1400/800
1400/800

64
64
128
128
192
192
256
256
640
640

0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.81
0.81

0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
1.9
1.9

26
26
52
52
78
78
104
104
376
376

0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.87
0.87

0.14
0.14
0.14
0.14
0.14
0.14
0.14
0.14
1.98
1.98

49
49
51
51
54
54
55
55
60
60

34
34
37
37
39
39
40
40
48
48

Note: Power per unit currents per motor


Dimensions Defrost Data
Dimensions
Model
D
D
D
D
D
D
D
D
D
D

S
S
S
S
S
S
S
S
S
S

Note:

C
C
C
C
C
C
C
C
C
C

*
*
*
*
*
*
*
*
*
*

1
2
3
4
5
6
6
8
1
1

9
2
6
2
1
2
8
3
0 0
1 6

Length
mm
870
870
1320
1320
1820
1820
2320
2320
2320
2320

Defrost

Height
mm

Width
mm

Coil
kW

266
266
266
266
266
266
266
266
351
351

910
910
910
910
910
910
910
910
910
910

0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
2.00
2.00

Tray
kW
1.58
1.58
2.85
2.85
4.27
4.27
5.70
5.70
5.67
5.67

See general notes on page 8, HS = High speed, LS = Low speed

12

F -X C h a n ge

F -X C h a n ge

W
N
O
y

ac

.c

tr

k e r- s o ft w a

Direct expansion - CX
Model
T
T
T
T
T
T
T
T
T

E
E
E
E
E
E
E
E
E

C
C
C
C
C
C
C
C
C

X 1
X 2
X 3
X 3 . 5
X 4
X5
X 6
X 7
X 8

Conn Size

Capacity
kW

Air Vol.
m3 /s

Surface
m2

Int. Vol.
dm3

Weight
AL - kg

inlet

outlet

Air Throw
m

0.34
0.66
0.84
1.00
1.37
1.81
2.22
2.86
3.30

0.16
0.14
0.16
0.17
0.28
0.31
0.34
0.47
0.50

1.07
2.13
3.02
3.99
3.99
5.36
7.14
7.57
10.10

1
1
2
2
2
2
3
3
4

8
9
11
14
15
19
21
27
31

3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8

5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8

4
4
4
4
4
5
5
5
5

Capacity
kW

Air Vol.
m3 /s

Surface
m2

Int. Vol.
dm3

Weight
AL - kg

inlet

outlet

Air Throw
m

0.50
0.84
1.02
1.19
1.75
2.17
2.56
3.35
3.82

0.16
0.14
0.16
0.17
0.28
0.31
0.34
0.47
0.50

1.07
2.13
3.02
3.99
3.99
5.36
7.14
7.57
10.10

1
1
2
2
2
2
3
3
4

8
9
11
14
15
19
21
27
31

3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8

5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8

4
4
4
4
4
5
5
5
5

Pump cirulation - CP
Model
T
T
T
T
T
T
T
T
T

E
E
E
E
E
E
E
E
E

C
C
C
C
C
C
C
C
C

P
P
P
P
P
P
P
P
P

1
2
3
3 . 5
4
5
6
7
8

Conn Size

Fan & Noise Data


Fan Detail
Model
T
T
T
T
T
T
T
T
T

G
G
G
G
G
G
G
G
G

C
C
C
C
C
C
C
C
C

*
*
*
*
*
*
*
*
*

Dia
mm
230
230
230
230
230
230
230
230
230

Qty

1
2
3
3 . 5
4
5
6
7
8

1
1
1
1
2
2
2
3
3

Speed
rpm
1400
1400
1400
1400
1400
1400
1400
1400
1400

Noise
Power
W
62
62
62
62
124
124
124
186
186

FLC
A
0.48
0.48
0.48
0.48
0.48
0.48
0.48
0.48
0.48

SC
A
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

dB(A)
@3m
57
55
56
56
59
57
55
60
58

Note: Power per unit currents per motor

Dimensions Defrost Data


Defrost

Dimensions
Model
T
T
T
T
T
T
T
T
T

Note:

E
E
E
E
E
E
E
E
E

C
C
C
C
C
C
C
C
C

*
*
*
*
*
*
*
*
*

1
2
3
3 . 5
4
5
6
7
8

Length
mm

Height
mm

Width
mm

Coil
kW

Tray
kW

525
525
690
865
865
1120
1120
1530
1530

180
180
180
180
180
180
230
180
230

375
375
375
375
375
375
375
375
375

275
550
700
900
900
1000
1000
1400
1400

2 x 250
2 x 250
2 x 325
2 x 425
2 x 425
2 x 575
2 x 675
2 x 1030
2 x 1030

L
W

See general notes on page 8, HS = High speed, LS = Low speed

om

lic

om

k
lic
C

.c

re

k e r- s o ft w a

ac

ww

ww

tr

to

to

bu

N
O

TEC Evaporator range

bu

PD

PD

13

re

F -X C h a n ge

F -X C h a n ge

W
N
O
y
bu

GEA Searle
20 Davis Way, Newgate Lane, Fareham, PO14 1AR
Tel.+4 4 (0) 1329 823344, Fax +4 4 (0) 1329 821242