Anda di halaman 1dari 5

DDEC FOR MBE900 AND MBE4000

5.11

IDLE SHUTDOWN TIMER AND VSG SHUTDOWN

The Idle Shutdown Timer will shutdown the engine if it remains idling for a specified period of
time. The options that can operate with Idle Shutdown Timer are Idle Shutdown Override, Vehicle
Power Shutdown or Shutdown on Variable Speed Governor (VSG).

5.11.1

OPERATION

Certain conditions must be met for the entire time-out period for shutdown to occur. These
conditions include:
Coolant temperature above 14 F (10 C)
Engine operation at idle
The parking brake interlock digital input switched to battery ground
OEM supplied interlocks enabled
Ignition ON
Fueling is stopped after the specified idle time; the ignition circuit remains active after the engine
shuts down. The AWL will flash 20 seconds before the shutdown occurs. The RSL will flash 10
seconds before shutdown occurs. The AWL will blink until the ignition is turned off to indicate
shutdown has occurred. The ignition switch must be cycled to OFF (wait 10 seconds) and back to
ON before the engine will restart, if shutdown occurs.

All information subject to change without notice.

7SA825 0403 Copyright 2004 DETROIT DIESEL CORPORATION

5-53

FEATURES

A Park Brake Switch may be installed (see Figure 5-14). Idle Shutdown Timer operates with a
digital input configured as a park brake and switched to battery ground. The time can range from
1 to 1000 seconds (approximately 16 minutes).

Figure 5-14

Park Brake Digital Input

Idle Shutdown Override - Optional


Idle Shutdown Override allows the operator to override the idle shutdown to keep the engine
idling if this feature is enabled.
If the accelerator pedal has been pressed or the park brake has been released, the conditions for the
idle shutdown are no longer valid. The shutdown conditions must be met to reinitialize the counter.
The timer can be reset by one of the following conditions:
Engine Shutdown override button has been pressed (if configured)
Clutch pedal has been pressed (if configured)
Service brake has been pressed (if configured)
Accelerator has been pressed above the idle position or has been fully pressed and released
Park Brake has been released

5-54

All information subject to change without notice.

7SA825 0403 Copyright 2004 DETROIT DIESEL CORPORATION

DDEC FOR MBE900 AND MBE4000

Vehicle Power Shutdown - Optional


Vehicle Power Shutdown is used with Idle Timer Shutdown or Engine Protection Shutdown.
After the idle timer times out or engine protection shuts the engine down, the Vehicle Power
Shutdown relay shuts down the rest of the electrical power to the vehicle.
A Vehicle Power Shutdown relay can be installed to shutdown all electrical loads when the
engine is shutdown (see Figure 5-15). The engine will shutdown after the specified idle time and
will reset the relay (ignition circuit).

Figure 5-15

Vehicle Power Shutdown Relay

All electrical loads that should be turned OFF when the engine shuts down should be wired
through this relay.

Shutdown on VSG - Optional


This option, when enabled, allows the engine to be shutdown when operating on VSG when the
conditions are met for the Idle Timer Shutdown.

Maximum Engine Load Shutdown Optional


This option, when enabled, allows the setting of a maximum load above which idle shutdown is
disabled.

All information subject to change without notice.

7SA825 0403 Copyright 2004 DETROIT DIESEL CORPORATION

5-55

FEATURES

5.11.2

PROGRAMMING REQUIREMENTS AND FLEXIBILITY

To program the Idle Shutdown timer, the digital inputs listed in Table 5-44 must be configured.
Description

Pin

Type

Setting

Default

Parameter
ID

Park Brake

21/16

Digital Input

0 = Disabled
1 = Enabled

1 13 08

Digital Input

0 Hardwired
1 Source Address 1 (SA1)
2 Source Address 2 (SA2)
3 Source Address 3 (SA3)

1 13 09

Park Brake
Input
Configuration

Table 5-44

Idle Shutdown Timer Digital Input

All the Idle Shutdown timer options are listed in Table 5-45.

5-56

All information subject to change without notice.

7SA825 0403 Copyright 2004 DETROIT DIESEL CORPORATION

DDEC FOR MBE900 AND MBE4000

Parameter

Description

Choice / Range

IDLE SHUTDOWN
ENABLE

Enables or Disables the


Idle Shutdown feature.

0 = Disable
1 = Enable with Park Brake
2 = Enable without Park
Brake, Reset for Accelerator
Position > Idle
3 = Enable without Park
Brake, Reset for Change in
Accelerator Pedal Position

IDLE SHUTDOWN
TIME (MIN)

The amount of engine


idle time that is
allowed before the
Idle Shutdown feature
stops fueling the engine.

1 to 5000 seconds

Enables or disables the


Idle Timer Shutdown
feature when operating
on the Variable Speed
Governor.

0 = Disable
1 = Enable with Park Brake
2 = Enable without Park
Brake, Reset for Accelerator
Position > Idle
3 = Enable without Park
Brake, Reset for Change in
Accelerator Pedal Position

VSG SHUTDOWN
ENABLE

VSG SHUTDOWN
TIME

MIN COOLANT TEMP


FOR SHUTDOWN

The amount of engine


idle time that is allowed
before the idle shutdown
feature stops fueling the
engine.
Minimum coolant
temperature before
an idle shutdown will
occur

Default

60 sec

Parameter
ID

Access

1 17 01

Nexiq DDR,
DDDL,
DRS,
VEPS,
minidiag2

1 17 02

Nexiq DDR,
DDDL,
DRS,
VEPS,
minidiag2

1 17 03

Nexiq DDR,
DDDL,
DRS,
VEPS,
minidiag2

1 to 5000 seconds

60 sec

1 17 04

Nexiq DDR,
DDDL,
DRS,
VEPS,
minidiag2

-40 C to 200 C

-10 C

1 17 08

VEPS,
DRS,
minidiag2

ENABLE IDLE/VSG
SHUTDOWN
OVERRIDE

Enables/disables
override of Idle or VSG
Shutdown

0 = Disable
1 = Enable

1 17 09

MAX ENGINE
LOAD FOR VSG
SHUTDOWN

VSG shutdown disabled


for engine loads greater
than this value

05000 Nm

100

1 17 05

Table 5-45

Nexiq DDR,
DDDL,
DRS,
VEPS,
minidiag2
VEPS,
DRS,
minidiag2

Idle Shutdown Timer Programming Options

All information subject to change without notice.

7SA825 0403 Copyright 2004 DETROIT DIESEL CORPORATION