:___________________________
Condenser vent to scrubber
UHP N2 Header
Nitrogen
Vacuum
Nitrogen
Vacuum
Lamp
250
lts
SS
316
PS/80
4
100
lts
SS
316
GLR/855
630 lts
CWR
HWR
CHBR
LPS
CWS
HWS
CHBS
CHBR
`
25 NB SS 316
CWR
Weighing balance
CWS
25 NB SS 316
25 NB MSPTFE with flange guards
N2
UHP N2
Header
CWR
HWR
CHBR
CHBR
LPS
GLR/866
1600 lts
25 NB SS/MS PTFE
GLR/865
5000 lts
CWS
HWS
CHBS
CWS
HWS
CHBS
Condensate
25 NB SS/ MSPTFE
Methyl THF from Drums
25 NB SS 316
25 NB SS 316
ST/ 845
SS316
ST/850
CAP-1000L
1.0 KL
SS316
MT/803
0.5 KL
SS316
L
C
ST/84
0.5
6 0.5
KL
KL
SS316
SS316
L
C
Critical process line (Use less flange joints & flange guards are required
Proposed Modification for scrubber header line
Proposed Modification
Signatures of
Requestor : Production :
QCD
:
R&D
:
Engg.
:
25 NB SS 316
Warehouse :
RA
:
SH&E
:
TSD
:
Others :
QA
:
PROPOSED MODIFICATION
crubber
Scrubber
Vacuum
Nitrogen
SSR/869
lts 500
CWR
HWR
CHBR
LPS
CWS
HWS
CHBS
Process water
Vacuum
ST/883
1.0 KL
SS316
CHBS
Nitrogen
ST/848
1.0 KL
SS316
Vent
Vacuum
ST/
To SSR/859
865
25 NB SS 316
Vacuum
Sample point
1'' SS316
CWR
HWR
CHBR
CHBR
LPS
CHBR
LPS
GLR/863
5000 lts
CWS
HWS
CHBS
40 NB SS 316
25 NB SS/ MSPTFE
N2
PNF/810
0.5 KL
SS316
PG
5 m3/hr
Note:
Header for UHP Nitrogen handling header with 4 nipples for GLR/855,GLR/865, PS/804 and 250 L SS Tank.
Flange gaurds for Triphosgene solution transferring line.
Encloser for GLR/855.
Load cell for ST/850 (4 nos).
Lamp for inside the encloser of GLR/855 (Inter lock with scrubber).
Weighing balance inside encloser of GLR/855.
Scrubber tapping inside the enclosure near GLR/855 manhole and weighing balance.
Scrubber
Aq NaOH 5%
soluation
Nitrogen
Vacuum
Lamp
GLR/834
250 lts
50 lts
SS
316
CT/80
8
CWR
HWR
CHBR
LPS
CWS
HWS
CHBS
CHBR
`
25 NB SS 316
CWR
Weighing balance
CWS
UHP N2
Header
SSR/850
1000 lts
CWR
HWR
CHBR
LPS
SSR/809
25 NB SS/MS PTFE
CWS
HWS
CHBS
CWS
HWS
CHBS
SSR/809
1600 lts
Condensate
25 NB SS/ MSPTFE
Methyl THF from Drums
25 NB SS 316
MT/80
3
500
LTS
LC
25 NB SS 316
LC
ST/ 856
SS316
ST/855
CAP-1000L
1.0 KL
SS316
ST/84
1.0
6 0.5
KL
KL
SS316
SS316
Critical process line (Use less flange joints & flange guards are required
Proposed Modification for scrubber header line
Proposed Modification
Signatures of
Requestor : Production :
QCD
:
R&D
:
Engg.
:
25 NB SS 316
Warehouse :
RA
:
SH&E
:
TSD
:
Others :
QA
:
PROPOSED MODIFICATION
scrubber
Scrubber
GLR/824
GLR/82
lts 500
4
250
LTS
CWS
HWS
CHBS
CWR
HWR
CHBR
LPS
CWS
HWS
CHBS
SSR/835
500 LTS
CHBS
Nitrogen
Vent
Vacuum
ST/
865
25 NB SS 316
Vaccum
Nitrogen
N2
Vacuum
1'' SS316
Sample point
GLR/811
CWR
HWR
CHBR
LPS
ST/88
9
50
LTS
GLR/811
3000 lts
CWS
HWS
CHBS
40 NB SS 316
25 NB SS/ MSPTFE
N2
PNF/810
0.5 KL
SS316
PG
5 m3/hr
Note:
Header for UHP Nitrogen handling header with 4 nipples for SSR/809,GLR/811,GLR/834, ST/889.
Flange gaurds for Triphosgene solution transferring line.
Encloser for GLR/834.
Scrubber
Aq NaOH 5%
soluation
Nitrogen
Vacuum
Lamp
GLR/834
250 lts
50 lts
SS
316
CT/80
8
CWR
HWR
CHBR
LPS
CWS
HWS
CHBS
CHBR
`
25 NB SS 316
CWR
Weighing balance
CWS
UHP N2
Header
SSR/803
1000 lts
CWR
HWR
CHBR
LPS
SSR/804
25 NB SS/MS PTFE
CWS
HWS
CHBS
CWS
HWS
CHBS
SSR/804
1600 lts
Condensate
25 NB SS/ MSPTFE
Methyl THF from Drums
25 NB SS 316
MT/80
3
500
LTS
LC
`
25 NB SS 316
LC
ST/ 856
SS316
ST/855
CAP-1000L
1.0 KL
SS316
Proposed Modification
Signatures of
Requestor : Production :
QCD
:
R&D
:
Engg.
:
ST/84
1.0
6 0.5
KL
KL
SS316
SS316
25 NB SS 316
Warehouse :
RA
:
SH&E
:
TSD
:
Others :
QA
:
PROPOSED MODIFICATION
scrubber
Scrubber
GLR/824
GLR/82
lts 500
2
250
LTS
CWS
HWS
CHBS
CWR
HWR
CHBR
LPS
CWS
HWS
CHBS
SSR/835
500 LTS
CHBS
Nitrogen
Vent
Vacuum
ST/
865
25 NB SS 316
Vaccum
Nitrogen
N2
Vacuum
1'' SS316
Sample point
GLR/811
3000 lts
CWR
HWR
CHBR
LPS
ST/88
9
50
LTS
GLR/811
3000 lts
CWS
HWS
CHBS
40 NB SS 316
25 NB SS/ MSPTFE
N2
PNF/810
0.5 KL
SS316
PG
5 m3/hr
Scrubber
Aq NaOH 5%
soluation