Bachelor of Technology
in
Civil Engineering
Submitted By
PAUL JOMY (SYAKECE033)
BONAFIDE CERTIFICATE
Mr. ARUN.K.A
Guide
Asst. Professor
Civil Engg
SIMAT, Vavanoor
Mr. SUDHEER.K.V
Head of the Dept
Civil Engg
SIMAT, Vavanoor
Palakkad
Internal Examiner
External Examiner
Date :
Date :
ABSTRACT
The increase in the number of terrorist attacks especially in the last few years has
shown that the effect of blast loads on buildings is a serious matter that should be taken
into consideration in the design process. Although these kinds of attacks are exceptional cases, man-made disasters; blast loads are in fact dynamic loads that need to be
carefully calculated just like earthquake and wind loads.
The objective of this study is to shed light on blast resistant building design theories, the enhancement of building security against the effects of explosives in both
architectural and structural design process and the design techniques that should be
carried out. Firstly, explosives and explosion types have been explained briefly. In
addition, the general aspects of explosion process have been presented to clarify the
effects of explosives on buildings. To have a better understanding of explosives and
characteristics of explosions will enable us to make blast resistant building design
much more efficiently. Essential techniques for increasing the capacity of a building to
provide protection against explosive effects is discussed both with an architectural and
structural approach.
ACKNOWLEDGEMENT
I am extremely thankful to our Principal Dr.S.P. SUBRAMANIAN for giving his consent for this seminar. And also im thankful to Mr. SUDHEER.K.V, Head of the
Department of Civil engineering, for his valuable suggestions and support. The valuable help and encouragement rended in this endeavour by my guide Mr. ARUN.K.A,
Asst.Professors, Dept.of Civil Engineering for his constant help and support throughout the presentation of the seminar by providing timely advices and guidance. I thank
God almighty for all the blessing received during this endeavor. Last, but not least I
thank all my friends for the support and encouragement they have given me during the
course of my work.
Contents
List of Figures
iii
Introduction
1.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Objective Of The Blast Design . . . . . . . . . . . . . . . . . . . . .
1
1
1
Literature survey
2.1 General . . . . . . . . . . . . . . . . . . . . . .
2.2 Explosion - Major of All Terrorist Activities . . .
2.2.1 Expected Terrorist Blast On Structures . .
2.2.2 Major Cause of Life Loss After The Blast
2.3 Goals of Blast Resistant Design . . . . . . . . .
2.4 Basic Requirements To Resist Blast Loads . . . .
2.4.1 Mechanics of a Conventional Explosion .
2.5 Types of Explosions . . . . . . . . . . . . . . . .
2.5.1 Unconfined Explosion . . . . . . . . . .
2.5.2 Confined Explosions . . . . . . . . . . .
2.6 Explosion Process For High Explosive . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3
3
3
3
3
4
4
4
5
5
6
6
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
9
9
9
9
11
11
12
12
13
13
14
14
14
14
15
15
.
.
.
.
.
.
.
.
.
.
.
17
17
19
20
21
Case Study
5.1 World Trade Center Collapse . . . . . . . . . . . . . . . . . . . . .
5.1.1 The Design . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1.2 The Details of The Impact . . . . . . . . . . . . . . . . . .
5.1.2.1 The Airplane Impact . . . . . . . . . . . . . . . .
5.1.2.2 The Collapse . . . . . . . . . . . . . . . . . . . .
5.1.3 Can Building Resist Direct Airplane Hits . . . . . . . . . .
5.1.4 How Can We Minimize The Chance of Progressive Collapse
5.2 Israel as a Case Study And Paradigm . . . . . . . . . . . . . . . . .
23
23
23
24
24
27
28
29
29
Conclusion
.
.
.
.
.
.
.
.
34
References
36
ii
List of Figures
2.1
2.2
2.3
2.4
.
.
.
.
5
6
6
7
3.1
3.2
10
11
4.1
4.2
17
4.3
4.4
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
5.10
5.11
iii
. . . .
details
. . . .
. . . .
. . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. . . . . . . . . . . . .
for steelwork and rein. . . . . . . . . . . . .
. . . . . . . . . . . . .
. . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
18
20
20
24
25
26
27
30
31
31
32
32
33
33
Chapter 1
Introduction
1.1
General
The increase in the number of terrorist attacks especially in the last few years has
shown that the effect of blast loads on buildings is a serious matter that should be taken
into consideration in the design process. Although these kinds of attacks are exceptional cases, man-made disasters; blast loads are in fact dynamic loads that need to be
carefully calculated just like earthquake and wind loads.
The objective of this study is to shed light on blast resistant building design theories, the enhancement of building security against the effects of explosives in both
architectural and structural design process and the design techniques that should be
carried out. Firstly, explosives and explosion types have been explained briefly. In
addition, the general aspects of explosion process have been presented to clarify the
effects of explosives on buildings. To have a better understanding of explosives and
characteristics of explosions will enable us to make blast resistant building design
much more efficiently. Essential techniques for increasing the capacity of a building to
provide protection against explosive effects is discussed both with an architectural and
structural approach.
Damage to the assets, loss of life and social panic are factors that have to be minimized if the threat of terrorist action cannot be stopped. Designing the structures to
be fully blast resistant is not an realistic and economical option, however current engineering and architectural knowledge can enhance the new and existing buildings to
mitigate the effects of an explosion.
1.2
The primary objectives for providing blast resistant design for buildings are:
-Personnel safety
-Controlled shutdown
-Financial consideration
Blast resistant design should provide a level of safety for persons in the building
that is no less than that for persons outside the buildings in the event of an explosion.
Evidence from past incidents has shown that many of the fatalities and serious injuries
were due to collapse of buildings onto the persons inside the building. This objective
is to reduce the probability that the building itself becomes a hazard in an explosion.
Preventing cascading events due to loss of control of process units not involved in
the event is another objective of blast resistant design. An incident in one unit should
not affect the continued safe operation or orderly shutdown of other units.
Preventing or minimizing financial losses is another objective of blast resistant
design. Buildings containing business information, critical or essential equipment,
expensive and long lead time equipment, or equipment which if destroyed, would constitute significant interruption or financial loss to the owner should be protected.
Chapter 2
Literature survey
2.1
General
The need and requirements for blast resistance in buildings have evolved over recent
years. Buildings have become more complex and have increased in size thus increasing the risk of accidental explosions. Such explosions have demolished the buildings,
in some cases resulting in substantial personnel causalities and business losses. Such
events have heightened the concerns of the industry, plant management, and regulatory agencies about the issues of blast protection in buildings have the potential for
explosions. Generally, these issues relate to plant building safety and risk management to prevent or minimize the occurrence of such incidents and to siting, design, and
operations.
2.2
The probability that any single building will sustain damage from accidental or deliberate explosion is very low, but thecost for those who are unprepared is very high.
2.3
2.4
over the entire structure. In short by purely geometrical relations, the larger the standoff, the more uniform the pressure distribution over the target. Eventually, the entire
structure is engulfed in the shock wave, with reflection and diffraction effects creating
focusing and shadow zones in a complex pattern around the structure. Following the
initial blast wave, the structure is subjected to a negative pressure, suction phase and
eventually to the quasi-static blast wind. During this phase, the weakened structure
may be subjected to impact by debris that may cause additional damage
2.5
Types of Explosions
explosion, the detonation of the high explosive occurs above the ground level and
intermediate amplification of the wave caused by ground reflections occurs prior to the
arrival of the initial blast wave at a building Figure 2.1.
As the shock wave continues to propagate outwards along the ground surface, a
front commonly called a Mach stem is formed by the interaction of the initial wave
and the reflected wave.
However a surface burst explosion occurs when the detonation occurs close to or
on the ground surface. The initial shock wave is reflected and amplified by the ground
surface to produce a reflected wave. Figure 2.2. Unlike the air burst, the reflected wave
merges with the incident wave at the point of detonation and forms a single wave. In
the majority of cases, terrorist activity occurres in built-up areas of cities, where de-
Figure 2.3: Fully vented, partially vented and fully confined explosions
2.6
An explosion occurs when a gas, liquid or solid material goes through a rapid chemical reaction. When the explosion occurs, gas products of the reaction are formed at a
6
very high temperature and pressure at the source. These high pressure gasses expand
rapidly into the surrounding area and a blast wave is formed. Because the gases are
moving, they cause the surrounding air move as well. The damage caused by explosions is produced by the passage of compressed air in the blast wave. Blast waves
propagate at supersonic speeds and reflected as they meet objects. As the blast wave
continues to expand away from the source of the explosion its intensity diminishes and
its effect on the objects is also reduced. However, within tunnels or enclosed passages,
the blast wave will travel with very little diminution.
Close to the source of explosion the blast wave is formed and violently hot and
expanding gases will exert intense loads which are difficult to quantify precisely. Once
the blast wave has formed and propagating away from the source, it is convenient
to separate out the different types of loading experienced by the surrounding objects.
Three effects have been identified in three categories. The effect rapidly compressing
the surrounding air is called air shock wave. The air pressure and air movement effect
due to the accumulation of gases from the explosion chemical reactions is called dynamic pressure and the effect rapidly compressing the ground is called ground shock
wave.
The air shock wave produces an instantaneous increase in pressure above the ambient atmospheric pressure at a point some distance from the source. This is commonly
referred to as overpressure. As a consequence, a pressure differential is generated between the combustion gases and the atmosphere, causing a reversal in the direction of
flow, back towards the center of the explosion, known as a negative pressure phase.
This is a negative pressure relative to atmospheric , rather than absolute negative pressure Figure 2.4. Equilibrium is reached when the air is returned to its original state.
As a rough approximation, 1kg of explosive produces about 1m3 of gas. As this
gas expands, its act on the air surrounding the source of the explosion causes it to move
7
and increase in pressure. The movement of the displaced air may affect nearby objects
and cause damage. Except for a confinement case, the effects of the dynamic pressure
diminish rapidly with distance from source.
The ground shock leaving the site of an explosion consists of three principal components . A compression wave which travels radially from the source; a shear wave
which travels radially and comprises particle movements in a plane normal to the radial direction where the ground shock wave intersects with the surface and a surface or
Raleigh wave. These waves propagate at different velocities and alternate at different
frequencies.
Chapter 3
Architectural Aspect of Blast Resistant Building Design
3.1
General
The target of blast resistant building design philosophy is minimizing the consequences
to the structure and its inhabitants in the event of an explosion. A primary requirement
is the prevention of catastrophic failure of the entire structure or large portions of it.
It is also necessary to minimize the effects of blast waves transmitted into the building through openings and to minimize the effects of projectiles on the inhabitants of
a building. However, in some cases blast resistant building design methods, conflicts
with aesthetical concerns, accessibility variations, fire fighting regulations and the construction budget restrictions.
3.2
Much can be done at the planning stage of a new building to reduce potential threats
and the associated risks of injury and damage. The risk of a terrorist attack, necessity of
blast protection for structural and non-structural members, adequate placing of shelter
areas within a building should be considered for instance. In relation to an external
threat, the priority should be to create as much stand-off distance between an external
bomb and the building as possible. On congested city centers there may be little or
no scope for repositioning the building, but what small stand-off there is should be
secured where possible. This can be achieved by strategic location of obstructions
such as bollards, trees and street furniture. Figure 4.1 shows a possible external layout
for blast safe planning.
3.3
Structural form is a parameter that greatly affects the blast loads on the building.
Arches and domes are the types of structural forms that reduce the blast effects on
the building compared with a cubicle form. The plan-shape of a building also has a
significant influence on the magnitude of the blast load it is likely to experience. Complex shapes that cause multiple reflections of the blast wave should be discouraged.
Projecting roofs or floors, and buildings that are U-shaped on plan are undesirable for
9
this reason. It should be noted that single story buildings are more blast resistant compared with multi-story buildings if applicable.
Partially or fully embed buildings are quite blast resistant. These kinds of structures take the advantage of the shock absorbing property of the soil covered by. The
soil provides protection in case of a nuclear explosion as well.
The internal layout of the building is another parameter that should be undertaken
with the aim of isolating the value from the threat and should be arranged so that the
highest exterior threat is separated by the greatest distance from the highest value asset.
Foyer areas should be protected with reinforced concrete walls; double-dooring should
be used and the doors should be arranged eccentrically within a corridor to prevent the
blast pressure entering the internals of the building. Entrance to the building should be
controlled and be separated from other parts of the building by robust construction for
greater physical protection. An underpass beneath or car parking below or within the
building should be avoided unless access to it can be effectively controlled.
A possible fire that occurs within a structure after an explosion may increase the
damage catastrophically. Therefore the internal members of the building should be
designed to resist the fire.
10
3.4
The bomb shelter areas are specially designated within the building where vulnerability from the effects of the explosion is at a minimum and where personnel can retire
in the event of a bomb threat warning. These areas must afford reasonable protection
against explosions; ideally be large enough to accommodate the personnel involved
and be located so as to facilitate continual access. For modern-framed buildings, shelter areas should be located away from windows, external doors, external walls and the
top floors if the roof is weak. Areas surrounded by full-height concrete walls should
be selected and underground car parks, gas storage tanks, areas light weight partition
walls, e.g. internal corridors, toilet areas, or conference should be avoided while locating the shelter areas. Basements can sometimes be useful shelter areas, but it is
important to ensure that the building does not collapse on top of them. The functional
aspects of a bomb shelter area should accommodate all the occupants of the building;
provide adequate communication with outside; provide sufficient ventilation and sanitation; limit the blast pressure to less than the ear drum rupture pressure and provide
alternative means of escape.
3.5
Installation
Gas, water, steam installations, electrical connections, elevators and water storage systems should be planned to resist any explosion affects. Installation connections are
critical points to be considered and should be avoided to use in high-risk deformation
areas. Areas with high damage receiving potential e.g. external walls, ceilings, roof
slabs, car parking spaces and lobbies also should be avoided to locate the electrical
and other installations. The main control units and installation feeding points should
be protected from direct attacks. A reserve installation system should be provided for
a potential explosion and should be located remote from the main installation system.
11
3.6
Glass from broken and shattered windows could be responsible for a large number of
injuries caused by an explosion in a city centre. The choice of a safer glazing material
is critical and it has been found out that laminated glass is the most effective in this
context. On the other hand, applying transparent polyester anti-shatter film to the inner
surface of the glazing is as well an effective method.
For the cladding, several aspects of design should be considered to minimize the
vulnerability of people within the building and damage to the building itself. The
amount of glazing in the facade should be minimized. This will limit the amount of
internal damage from the glazing and the amount of blast that can enter. It should
also be ensured that the cladding is fixed to the structure securely with easily accessible fixings. This will allow rapid inspection after an explosion so that any failure or
movement can be detected.
3.7
Floor Slabs
12
3.8
Columns
3.9
Transfer Girders
The building relies on transfer girders at the top of the atrium to distribute the loads of
the columns above the atrium to the adjacent columns outside the atrium. The transfer
girder spans the width of the atrium, which insures a column-free architectural space
for the entrance to the building.
Transfer girders typically concentrate the load-bearing system into a smaller number of structural elements. This loadtransfer system runs contrary to the concept of
redundancy desired in a blast environment. The column connections, which support
the transfer girders, are to provide sustained strength despite inelastic deformations.
The following recommendations must be met for transfer girders:
1. The transfer girder and the column connections must be properly designed and
detailed, using an adequate blast loading description.
2. A progressive-collapse analysis must be performed, particularly if the blast loading exceeds the capacity of the girder.
13
3.10
External Treatments
The two parameters that most directly influence the blast environment that the structure
will be subjected to are the bombs charge weight and the standoff distance. Of these
two, the only parameter that anyone has any control over is the standoff distance.
3.11
The facade is comprised of the glazing and the exterior wall. Better glazing has already
been discussed above and wall obviously should be hardened to resist the loading.
Presence of an atrium along the face of the structure will require two protective measures. On the outside of the structure, the glass and glass framing must be strengthened
to withstand the loads. On the inside, the balcony parapets, spandrel beams, and exposed slabs must be strengthened to withstand the loads that enter through the shattered
glass.
3.12
The ability of structures to resist a highly impulsive blast loading depends on the ductility of the load-resisting system.This means that the structure has to be able to deform in
elastically under extreme overload, thereby dissipating large amounts of energy, prior
to failure.. In addition to providing ductile behavior for the structure, the following
provisions would improve the blast protection capability of the building:
1. Use a well-distributed lateral-load resisting mechanism in the horizontal floor plan.
This can be accomplished by using several shear walls around the plan of the building
this will improve the overall seismic as well as the blast behavior of the building.
2. If adding more shear walls is not architecturally feasible, a combined lateral-load
resisting mechanism can also be used. A central shear wall and a perimeter momentresisting frame will provide for a balanced solution. The perimeter momentresisting
frame will require strengthening the spandrel beams and the connections to the outside
columns. This will also result in better protection of the outside columns.
Several recommendations were presented for each of the identified features. The
implementation of these recommendations will greatly improve the blast-resisting capability of the building under consideration.
3.13
The architectural design of the building of interest currently calls for window glass
around the first floor. Unless this area is constructed in reinforced concrete, the damage to the lower floor structural elements and their connections will be quite severe.
14
Consequently, the injury to the lower floor inhabitants will be equally severe. In general, two sizes of charges can be discussed
1. To protect against a small charge weight, a nominal 300 mm (12 in.) thick wall
with 0.3 percent steel doubly reinforced in both directions might be required.
2. For intermediate charge weight protection, a 460 mm (18 in.) thick wall with 0.5
percent steel might be needed.
3.14
The keep out distance, within which explosives-laden vehicles may not penetrate, must
be maximized and guaranteed. As we all know, the greater the standoff distance, the
more the blast forces will dissipate resulting in reduced pressures on the building. Several recommendations can be made to maintain and improve the standoff distance for
the building under consideration:
1. Use anti-ram bollards or large planters, placed around the entire perimeter. These
barriers must be designed to resist the maximum vehicular impact load that could be
imposed. For maximum effectiveness, the barriers-bollards or planters-must be placed
at the curb.
2. The public parking lot at the corner of the building must be secured to guarantee the
prescribed keepout distance from the face of the structure. Preferably, the parking lot
should be eliminated.
3. Street parking should not be permitted on the near side of the street, adjacent to
the building.
4. An additional measure to reduce the chances of an attack would be to prevent
parking on the opposite side of the street. While this does not improve the keep out
distance, it could eliminate the parked bomb, thereby limiting bombings to Park and
run.
3.15
The blast environment could be introduced into the interior of the structure in four vulnerable locations:
The entrance lobby, the basement mechanical rooms, the loading dock, and the
primary mail rooms. Specific modifications to the features of these vulnerable spaces
can prevent an internal explosion from causing extensive damage and injury inside the
building.
1. Walls and slabs adjacent to the lobby, loading dock, and mail rooms must be
15
hardened to protect against the hand delivered package bomb, nominally a 10-20 kg
explosive. This hardening can be achieved by redesigning the slabs and erecting castin-place reinforced-concrete walls, with the thickness and reinforcement determined
relative to the appropriate threat.
2. The basement must be similarly isolated from all adjacent occupied office space,
including the floor above, from the threat of a small package bomb.
16
Chapter 4
Structural Aspect of Blast Resistant Building
4.1
General
The front face of a building experiences peak overpressures due to reflection of an external blast wave. Once the initial blast wave has passed the reflected surface of the
building, the peak overpressure decays to zero. As the sides and the top faces of the
building are exposed to overpressures (which has no reflections and are lower than the
reflected overpressures on the front face), a relieving effect of blast overpressure is
experienced on the front face. The rear of the structure experiences no pressure until
the blast wave has traveled the length of the structure and a compression wave has
begun to move towards the centre of the rear face. Therefore the pressure built up is
not instantaneous. On the other hand, there will be a time lag in the development of
pressures and loads on the front and back faces.
This time lag causes translational forces to act on the building in the direction of
the blast wave.
Blast loadings are extra ordinary load cases however, during structural design, this
effect should be taken into account with other loads by an adequate ratio. Similar to
the static loaded case design, blast resistant dynamic design also uses the limit state
17
design techniques which are collapse limit design and functionality limit design. In
collapse limit design the target is to provide enough ductility to the building so that the
explosion energy is distributed to the structure without overall collapse. For collapse
limit design the behavior of structural member connections is crucial. In the case of
an explosion, significant translational movement and moment occur and the loads involved should be transferred from the beams to columns. The structure doesnt collapse
after the explosion however it cannot function anymore.
Functionality limit design however, requires the building to continue functionality after a possible explosion occurred. Only non-structural members like windows
or cladding may need maintenance after an explosion so that they should be designed
ductile enough.
When the positive phase of the shock wave is shorter than the natural vibration
period of the structure, the explosion effect vanishes before the structure responds.
This kind of blast loading is defined as impulsive loading. If the positive phase is
longer than the natural vibration period of the structure, the load can be assumed constant when the structure has maximum deformation. This maximum deformation is a
function of the blast loading and the structural rigidity. This kind of blast loading is
defined as quasi-static loading. Finally, if the positive phase duration is similar to the
natural vibration period of the structure, the behavior of the structure becomes quite
complicated. This case can be defined as dynamic loading. Frame buildings designed
Figure 4.2: Enhanced beam-to-column connection details for steelwork and reinforced
concrete
to resist gravity, wind loads and earthquake loads in the normal way have frequently
18
been found to be deficient in two respects. When subjected to blast loading; the failure of beam-to-column connections and the inability of the structure to tolerate load
reversal.Beam-to-column connections can be subjected to very high forces as the result
of an explosion. These forces will have a horizontal component arising from the walls
of the building and a vertical component from the differential loading on the upper and
lower surfaces of floors. Providing additional robustness to these connections can be a
significant enhancement.
In the connections, normal details for static loading have been found to be inadequate for blast loading. Especially for the steelwork beam-to-column connections, it is
essential for the connection to bear inelastic deformations so that the moment frames
could still operate after an instantaneous explosion. Figure 2.8 shows the side-plate
connection detail in question . The main features to note in the reinforced concrete
connection are the use of extra links and the location of the starter bars in the connection Figure 2.8. These enhancements are intended to reduce the risk of collapse or the
connection be damaged, possibly as a result of a load reversal on the beam.
It is vital that in critical areas, full moment-resisting connections are made in order
to ensure the load carrying capacity of structural members after an explosion. Beams
acting primarily in bending may also carry significant axial load caused by the blast
loading.
On the contrary, columns are predominantly loaded with axial forces under normal
loading conditions, however under blast loading they may be subjected to bending.
Such forces can lead to loss of load-carrying capacity of a section. In the case of an
explosion, columns of a reinforced concrete structure are the most important members
that should be protected. Two types of wrapping can be applied to provide this. Wrapping with steel belts or wrapping with carbon fiberreinforced polymers (CFRP).
Cast-insitu reinforced concrete floor slabs are the preferred option for blast resistant buildings, but it may be necessary to consider the use of precast floors in some
circumstances. Precast floor units are not recommended for use at first floor where the
risk from an internal explosion is greatest. Lightweight roofs and more particularly,
glass roofs should be avoided and a reinforced concrete or precast concrete slab is to
be preferred.
4.2
Structural Failure
An explosion will create blast wave. The air-blast shock wave is the primary damage mechanism in an explosion. The pressures it exerts on building surfaces may be
several orders of magnitude greater than the loads for which the building is designed.
The shock wave will penetrate and surround a structure and acts in directions that the
building may not have been designed for, such as upward force on the floor system.
In terms of sequence of response, the air-blast first impinges on the weakest point in
the vicinity of the device closest to the explosion, typically the exterior envelope of
19
the building. The explosion pushes on the exterior walls at the lower stories and may
cause wall failure and window breakage. As the shock wave continues to expand, it
enters the structure, pushing both upward and downward on the floor slabs
4.3
Blast wave and seismic loading are two different type of extreme force that may cause
structural failure. However, they share some common similarities. Similarities between seismic and blast loading includes the following:
20
4.4
1.Slab failure is typical in blasts due to large surface area subjected to upward pressure
not considered in gravity design.
2. Small database on blast effects on structures.
3.Seismic-resistant design is mature compared with blast-resistant design.
In summary, while the effect of blast loading is localized compared with an earthquake, the ability to sustain local damage without total collapse (structural integrity) is
a key similarity between seismic-resistant and blast-resistant design. In this study, the
21
evaluation data that had been listed in inspection form is adapted and modified from
inspection form for building after an earthquake. Even though, seismic loading will
cause global response to building compared to blast loading which will cause localized response, but similar damage assessment procedure could be used.
22
Chapter 5
Case Study
5.1
The collapse of the World Trade Center (WTC) towers on September 11, 2001, was as
sudden as it was dramatic; the complete destruction of such massive buildings shocked
nearly everyone. Immediately afterward and even today, there is widespread speculation that the buildings were structurally deficient, that the steel columns melted, or that
the fire suppression equipment failed to operate. In order to separate the fact from the
fiction, I have attempted to quantify various details of the collapse.
The major events include the following:
The airplane impact with damage to the columns. The ensuing fire with loss of steel
strength and distortion (figure 5.3)
The collapse, which generally occurred inward without significant tipping.(figure 5.4)
Before going to the details it is useful to review the overall design of the towers
loads would shift into adjacent columns and the building would remain standing). The
WTC was primarily a lightweight steel structure; however, its 244 perimeter columns
made it one of the most redundant and one of the most resilient skyscrapers.
The early news reports noted how well the towers withstood the initial impact of the
aircraft; however, when one recognizes that the buildings had more than 1,000 times
the mass of the aircraft and had been designed to resist steady wind loads of 30 times
the weight of the aircraft, this ability to withstand the initial impact is hardly surprising.
Furthermore, since there was no significant wind on September 11, the outer perimeter
columns were only stressed before the impact to around 1/3 of their 200 MPa design
allowable.
The only individual metal component of the aircraft that is comparable in strength
to the box perimeter columns of the WTC is the keel beam at the bottom of the aircraft
fuselage. While the aircraft impact undoubtedly destroyed several columns in the WTC
perimeter wall, the number of columns lost on the initial impact was not large and the
loads were shifted to remaining columns in this highly redundant structure. Of equal
or even greater significance during this initial impact was the explosion when 90,000
Lgallons of jet fuel, comprising nearly 1/3 of the aircrafts weight, ignited. The ensuing
fire was clearly the principal cause of the collapse (see figure 5.2)
24
Figure 5.2: A graphic illustration, from the USA Today newspaper web site, of the
World Trade Center points of impact.
The fire is the most misunderstood part of the WTC collapse.Even today, the media report (and many scientists believe) that the steel melted. It is argued that the jet
fuel burns very hot, especially with so much fuel present. This is not true. Part of
the problem is that people often confuse temperature and heat. While they are related,
they are not the same. Thermodynamically, the heat contained in a material is related
to the temperature through the heat capacity and the mass. Temperature is defined as
an intensive property, meaning that it does not vary with the quantity of material, while
the heat is an extensive property, which does vary with the amount of material. One
way to distinguish the two is to note that if a second log is added to the fireplace, the
temperature does not double; it stays roughly the same, but the length of time the fire
burns, doubles and the heat so produced is doubled. Thus, the fact that there were
90,000 L of jet fuel on a few floors of the WTC does not mean that this was an unusually hot fire. The temperature of the fire at the WTC was not unusual, and it was most
definitely not capable of melting steel.
In combustion science, there are three basic types of flames, namely, a jet burner,
a pre-mixed flame, and a diffuse flame. A jet burner generally involves mixing the
fuel and the oxidant in nearly stoichiometric proportions and igniting the mixture
in a constant-volume chamber. Since the combustion products cannot expand in the
constant-volume chamber, they exit the chamber as a very high velocity, fully com-
25
Figure 5.3: Flames and debris exploded from the World Trade Center south tower
immediately after the airplanes impact. The black smoke indicates a fuel-rich fire
busted, jet. This is what occurs in a jet engine, and this is the flame type that generates
the most intense heat.
In a pre-mixed flame, the same nearly stoichiometric mixture is ignited as it exits a
nozzle, under constant pressure conditions. It does not attain the flame velocities of a
jet burner. An oxyacetylene torch or a Bunsen burner is a premixed flame.
In a diffuse flame, the fuel and the oxidant are not mixed before ignition, but flow
together in an uncontrolled manner and combust when the fuel/oxidant ratios reach
values within the flammable range. A fireplace flame is a diffuse flame burning in air,
as was the WTC fire. Diffuse flames generate the lowest heat intensities of the three
flame types.
If the fuel and the oxidant start at ambient temperature, a maximum flame temperature can be defined. For carbon burning in pure oxygen, the maximum is 3,200C;
for hydrogen it is 2,750C. Thus, for virtually any hydrocarbons, the maximum flame
temperature, starting at ambient temperature and using pure oxygen, is approximately
3,000C. This maximum flame temperature is reduced by two-thirds if air is used rather
than pure oxygen. The reason is that every molecule of oxygen releases the heat of
26
formation of a molecule of carbon monoxide and a molecule of water. If pure oxygen is used, this heat only needs to heat two molecules (carbon monoxide and water),
while with air, these two molecules must be heated plus four molecules of nitrogen.
Thus, burning hydrocarbons in air produces only one-third the temperature increase as
burning in pure oxygen because three times as many molecules must be heated when
air is used. The maximum flame temperature increase for burning hydrocarbons (jet
fuel) in air is, thus, about 1,000Chardly sufficient to melt steel at 1,500C.
5.1.2.2
The Collapse
28
5.2
Over the course of its history, Israel has adapted military blast design to blast design to
be used as a part of civilian structures. Israels methods for integrating blast protection
into its society can be used as an example for the rest of the world as it is increasingly
29
In the 1970s civilians in Israel were being threatened along its border with Lebanon.
Katusha rockets were being launched over the Lebanese border into the Israeli cities
on the other side, and Israel needed to provide its citizens with protection from the
attacks. Throughout northern Israel rooms designed to protect a buildings inhabitants
from an explosion were included in most homes as well as schools and public buildings
(Sandler, 2003). This was the beginning of the transition from underground shelters,
separate from the buildings. To shelters integrated into daily structures.
The biggest change in Israels policy toward protecting its citizens came in 1991
with the Gulf war. Saddam Hussein threatened Israel with Scud missiles and this not
only increased the treat due to explosions, but also introduced the strong possibility of
bio-chemical threats. People were now required to have protected spaces within every
home, office, and public space. The windows had to be able to be sealed around the
edges, and doors would have a wet towel placed at the bottom. The room also had to be
30
blast proof so that in an attack craked walls and windows would not allow poisonous
gas to seep in.
New building requirements to have these protected spaces in all civilian structures,
and how to design these spaces were developed and known as Haga requirements (Einstein, 2003). These regulations were fully integrated into the Israeli building code and
continue to be maintained in order to protect Israeli civilians.
While the regulations being put into the building code was instigated by a need to
provide protection against chemical warfare , the importance of regulating the integration of protected spaces into buildings remains and extend into blast protection.
Protecting a building from explosions is now an integral part of a buildings design
31
out security risks while preserving the essence of the design (Einstein, 2003). Israeli
society cannot have all of its buildings feel like concrete fortified structures even if they
rely (Figures 2.13,2.14,2.15) are examples of Israeli blast designed structures, versus
the current blast designed structures in the United States.
Since September 11, 2001 and the destruction of the World Trade Centre due to
terrorism, it has become apparent that the U.S. must also change its approach to protecting its citizens from explosions. Israel has successfully integrated blast protection
into its society and buildings as a result of years of terror and threats. By making
blast protection a permanent part of the building code professionals have been forced
to come up with new ways of designing building s that protect their inhabitants but
still maintain peoples quality of life (Einstein, 2003). Because of the increased and
continuing threat to the United States it is clear that structural engineers here too will
have to make blast design an integral part of all structures. The more this mentality is
32
put into practice the sooner blast design will be able t coexist with current structural
design consideration such as architecture, sustainability, usability, and economics.
33
Chapter 6
Conclusion
The aim in blast resistant building design is to prevent the overall collapse of the building and fatal damages. Despite the fact that, the magnitude of the explosion and the
loads caused by it cannot be anticipated perfectly, the most possible scenarios will let
to find the necessary engineering and architectural solutions for it.
In the design process it is vital to determine the potential danger and the extent of
this danger. Most importantly human safety should be provided. Moreover, to achieve
functional continuity after an explosion, architectural and structural factors should be
taken into account in the design process, and an optimum building plan should be put
together.
This study is motivated from making buildings in a blast resistant way, pioneering
to put the necessary regulations into practice for preventing human and structural loss
due to the blast and other human-sourced hazards and creating a common sense about
the explosions that they are possible threats in daily life. In this context, architectural
and structural design of buildings should be specially considered.
During the architectural design, the behavior under extreme compression loading
of the structural form, structural elements e.g. walls, flooring and secondary structural
elements like cladding and glazing should be considered carefully. In conventional design, all structural elements are designed to resist the structural loads. But it should be
remembered that, blast loads are unpredictable, instantaneous and extreme. Therefore,
it is obvious that a building will receive less damage with a selected safety level and
a blast resistant architectural design. On the other hand, these kinds of buildings will
less attract the terrorist attacks.
Structural design after an environmental and architectural blast resistant design, as
well stands for a great importance to prevent the overall collapse of a building. With
correct selection of the structural system, well designed beam-column connections,
structural elements designed adequately, moment frames that transfer sufficient load
and high quality material; its possible to build a blast resistant building. Every single member should be designed to bear the possible blast loading. For the existing
structures, retrofitting of the structural elements might be essential. Although these
34
precautions will increase the cost of construction, to protect special buildings with terrorist attack risk like embassies, federal buildings or trade centers is unquestionable.
35
References
[1] Koccaz Z. (2004) Blast Resistant Building Design, MSc Thesis, Istanbul Technical University, Istanbul, Turkey.
[2] Smith P.D., Hetherington J.G. (1994) Blast and ballistic loading of structures.
Butterworth Heinemann.
[3] Yandzio E., Gough M. (1999). Protection of Buildings Against Explosions, SCI
Publication, Berkshire, U.K.
[4] Website : www.iitk.ac.in/nicee/wcee/article/14-05-01-0536.PDF
[5] Civil engineering articles at google.com
36