Anda di halaman 1dari 61

Evolution Series

User Manual
Part: Appendices
B4065 Rev. J

This manual is the property of Nera Networks AS. No parts of the manual may be copied, rewritten or distributed to third parties without the written permission from Nera
Networks AS.
For best readability, a screen resolution of at least 1280 by 1024 pixels is recommended.

In addition to the WEB edition, the manual is available in PDF format (suitable for print-out).
If you don't have Adobe Acrobat Reader installed on your computer, you can download it below.
Download Adobe Acrobat Reader

The manual is divided in 5 main parts:


General

This part gives a general overview of the Evolution Series equipment

Installation

Gives the details on how to install the equipment

Operation

Describes how to operate the system with emphasis on the Evolution Series Manager

Maintenance

Gives details on maintenance of the equipment

Appendices

A collection of frequency plans, alarm lists, technical specifications etc.

Table of Contents
General
Installation
Operation
Maintenance
Appendices
Frequency Plans
L6G
U6G
7G
8G
11G
13G
15G
18G
23G
26G
Alarm Lists
Element Alarms
IFU Alarms
IFU METRO Basic Frame Alarms
IFU XPAND Basic Frame Alarms
SU Alarms
LIU Electrical Alarms
LIU Optical Alarms
RIU Alarms
FAN Alarms
ODU Alarms
Auxiliary 64kb/s Alarms
EOW Alarms
ACU Alarms
E1/T1 Wayside Alarms
Gigabit Ethernet Alarms
E1/T1 Units Alarms
DS3/E3 Alarms
Performance Alarms
DXC Alarms
SETS Alarms
Mapping Structure
Mini Balun Termination
Gigabit Ethernet Config.
Abbreviations

Frequency Plans
Lower 6GHz
L6_4
L6_5
L6_6
L6_7
n#
1
2
3
4
5
6
7
8

ITU-R F.383-7 - CS(29.65) - DS(252.04) - 5.9-6.4


CEPT 14-01 E - CS(29.65) - DS(252.04) - 5.9-6.4
FCC 101.147 (i-8) - CS(29.65) - DS(252.04) - 5.9-6.4
SRSP-305.9 Group A - CS(29.65) - DS(252.04) - 5.9-6.4
RF-freq (MHz)
5945,2
5974,85
6004,5
6034,15
6063,8
6093,45
6123,1
6152,75

n'#
1'
2'
3'
4'
5'
6'
7'
8'

RF-freq (MHz)
6197,24
6226,89
6256,54
6286,19
6315,84
6345,49
6375,14
6404,79

L6_8

SRSP-305.9 Group B - CS(29.65) - DS(252.04) - 5.9-6.4

n#
1
2
3
4
5
6
7
8

RF-freq (MHz)
5930,37
5960,02
5989,67
6019,32
6048,97
6078,62
6108,27
6137,92

n'#
1'
2'
3'
4'
5'
6'
7'
8'

RF-freq (MHz)
6182,41
6212,06
6241,71
6271,36
6301,01
6330,66
6360,31
6389,96

Frequency Plans
Upper 6GHz
U6_8
n#
1
2
3
4
5
6
7
8
9
10

ITU-R F.384 - CS(30) - DS(340) - 6.4-7-1


RF-freq (MHz)
6460
6490
6520
6550
6580
6610
6640
6670
6700
6730

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'

RF-freq (MHz)
6800
6830
6860
6890
6920
6950
6980
7010
7040
7070

U6_9
U6_10

ITU-R F.384 - CS(40) - DS(340) - 6.4-7-1


CEPT 14-02 E - CS(40) - DS(340) - 6.4-7-1

n#
1
2
3
4
5
6
7
8

RF-freq (MHz)
6460
6500
6540
6580
6620
6660
6700
6740

U6_11
n#
1
2
3
4
5

n'#
1'
2'
3'
4'
5'
6'
7'
8'

RF-freq (MHz)
6800
6840
6880
6920
6960
7000
7040
7080

SRSP-306.4 - CS(30) - DS(340) - 6.4-7-1


RF-freq (MHz)
6445
6475
6505
6535
6565

n'#
1'
2'
3'
4'
5'

RF-freq (MHz)
6785
6815
6845
6875
6905

U6_12
n#
1
2
3

SRSP-306.4 - CS(30) - DS(100) - 6.4-7-1


RF-freq (MHz)
6595
6625
6655

n'#
1'
2'
3'

RF-freq (MHz)
6695
6725
6755

Frequency Plans
7GHz
ITU-R F.385-8 Rec 1-4 includes three channel arrangements with a Duplex spacing of 161 MHz.
7.125-7.425 f0 = 7 275
7.250-7.550 f0 = 7 400
7.425-7.725 f0 = 7 575
The actual channel BW can be set to 7 MHz, 14 MHz or 28 MHz, depending on selected datarate.
All channels can be used for all datarates.
The plans are based on the following formula:
lower half of the band: fn = f0 154 + 7 n
upper half of the band: fn = f0 + 7 + 7 n
where: n = 1, 2, 3, ..., 20;
Interleaved channels between ch 1-20 may also be used.
Due to the large number of channels no template is presented.

7_26
n#
1
2
3
4
5

CEPT 02-06 - CS(28) - DS(154) - 7.1-7.4


RF-freq (MHz)
7142
7170
7198
7226
7254

n'#
1'
2'
3'
4'
5'

RF-freq (MHz)
7296
7324
7352
7380
7408

7_27
7_28

ITU-R F.385-8 Annex 1, 1 - CS(28) - DS(154) - 7.4-7.7


CEPT 02-06 - CS(28) - DS(154) - 7.4-7.7

n#
1
2
3
4
5

RF-freq (MHz)
7442
7470
7498
7526
7554

n'#
1'
2'
3'
4'
5'

RF-freq (MHz)
7596
7624
7652
7680
7708

7_2 9

ITU-R F.385-8 Annex 1, 4 - CS(28) - DS(154) - 7.4-7.7

n#
1
2
3
4

RF-freq (MHz)
7456
7484
7512
7540

n'#
1'
2'
3'
4'

7_47

ITU-R F.385-8 Annex 3 - CS(28) - DS(154) - 7.4-7.7

n#
1
2
3
4
5

RF-freq (MHz)
7457
7485
7513
7541
7569

7_48

CS(28) - DS(182) - 7.4-7.7

n#
1
2
3
4
5

RF-freq (MHz)
7428
7456
7484
7512
7540

7_49

ITU-R F.385-8 Annex 3 - CS(28) - DS(196) - 7.1-7.4

n#
1
2
3
4
5

RF-freq (MHz)
7121
7149
7177
7205
7233

n'#
1'
2'
3'
4'
5'

n'#
1'
2'
3'
4'
5'

n'#
1'
2'
3'
4'
5'

RF-freq (MHz)
7610
7638
7666
7694

RF-freq (MHz)
7625
7653
7681
7709
7737

RF-freq (MHz)
7610
7638
7666
7694
7722

RF-freq (MHz)
7317
7345
7373
7401
7429

7_5 0

ITU-R F.385-8 Annex 4 - CS(28) - DS(245) - 7.4-7.9

n#
1
2
3
4
5
6
7
8

RF-freq (MHz)
7442
7470
7498
7526
7554
7582
7610
7638

n'#
1'
2'
3'
4'
5'
6'
7'
8'

7_51

SRSP-307.1 - CS(30) - DS(150) - 7.4-7.7

n#
1

RF-freq (MHz)
7440

7_52

SRSP-307.1 - CS(30) - DS(175) - 7.1-7.4

n#
1

RF-freq (MHz)
7140

7_53

Korea - CS(30) - DS(300) - 7.1-7.7

n#
1
2
3
4
5
6
7
8
9
10

RF-freq (MHz)
7140
7170
7200
7230
7260
7290
7320
7350
7380
7410

7_54

ACA RALI FX 3, App 1, 7.2 - 7.1-7.4

n#
1

RF-freq (MHz)
7130

n'#
1'

n'#
1'

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'

n'#
1'

RF-freq (MHz)
7687
7715
7743
7771
7799
7827
7855
7883

RF-freq (MHz)
7590

RF-freq (MHz)
7315

RF-freq (MHz)
7440
7470
7500
7530
7560
7590
7620
7650
7680
7710

RF-freq (MHz)
7400

Frequency Plans
8GHz
8_1
n#
1
2
3
4
5
6
7
8

8_2
n#
1
2
3
4
5
6
7
8

8_3
n#
1
2
3
4
5
6
7
8

ITU-R F.386-6 Annex 1 - CS(29.65) - DS(311.32) - 7.7-8.3


RF-freq (MHz)
7747,7
7777,35
7807
7836,65
7866,3
7895,95
7925,6
7955,25

n'#
1'
2'
3'
4'
5'
6'
7'
8'

RF-freq (MHz)
8059,02
8088,67
8118,32
8147,97
8177,62
8207,27
8236,92
8266,57

ITU-R F.386-6 Annex 1, 4 - CS(29.65) - DS(311.32) - 7.7-8.3


RF-freq (MHz)
7732,875
7762,525
7792,175
7821,825
7851,475
7881,125
7910,775
7940,425

n'#
1'
2'
3'
4'
5'
6'
7'
8'

RF-freq (MHz)
8044,195
8073,845
8103,495
8133,145
8162,795
8192,445
8222,095
8251,745

SRSP-307.7 - CS(30) - DS(300) - 7.7-8.3


RF-freq (MHz)
7740
7770
7800
7830
7860
7890
7920
7950

n'#
1'
2'
3'
4'
5'
6'
7'
8'

RF-freq (MHz)
8040
8070
8100
8130
8160
8190
8220
8250

8_4
n#
1
2
3
4
5
6

8_7
n#
1
2
3
4
5
6
7
8

8_11
n#
1
2
3
4
5
6
7
8
9
10

8_16
n#
1
2
3
4
5

Korea - CS(40) - DS(310) - 7.7-8.3


RF-freq (MHz)
7745
7785
7825
7865
7905
7945

n'#
1'
2'
3'
4'
5'
6'

RF-freq (MHz)
8055
8095
8135
8175
8215
8255

ITU-R F.386-6 Annex 4, 1 - CS(28) - DS(266) - 7.9-8.4


RF-freq (MHz)
7926
7954
7982
8010
8038
8066
8094
8122

n'#
1'
2'
3'
4'
5'
6'
7'
8'

RF-freq (MHz)
8192
8220
8248
8276
8304
8332
8360
8388

CEPT 02-06 - CS(28) - DS(310) - 7.9-8.5


RF-freq (MHz)
7919
7947
7975
8003
8031
8059
8087
8115
8143
8171

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'

RF-freq (MHz)
8229
8257
8285
8313
8341
8369
8397
8425
8453
8481

Norway - CS(28) - DS(154) - 8.2-8.5


RF-freq (MHz)
8217
8245
8273
8301
8329

n'#
1'
2'
3'
4'
5'

RF-freq (MHz)
8371
8399
8427
8455
8483

8_19
n#
1
2
3
4
5
6

8_20
n#
1
2
3
4
5
6
7
8
9
10
11
12

ITU-R F.386-6 Annex 3, 1.1 - CS(14) - DS(119) - 8.2-8.5


RF-freq (MHz)
8293
8307
8321
8335
8349
8363

n'#
1'
2'
3'
4'
5'
6'

RF-freq (MHz)
8412
8426
8440
8454
8468
8482

ITU-R F.386-6 Annex 3, 1.2 - CS(7) - DS(126) - 8.2-8.5


RF-freq (MHz)
8286
8293
8300
8307
8314
8321
8328
8335
8342
8349
8356
8363

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'

RF-freq (MHz)
8412
8419
8426
8433
8440
8447
8454
8461
8468
8475
8482
8489

Frequency Plans
11GHz
11_6
n#
1
2
3
4
5
6
7
8
9
10
11
12

ITU-R F.387-9 Rec. 1 - CS(40) - DS(530) - 10.7-11.7


RF-freq (MHz)
10715
10755
10795
10835
10875
10915
10955
10995
11035
11075
11115
11155

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'

RF-freq (MHz)
11245
11285
11325
11365
11405
11445
11485
11525
11565
11605
11645
11685

11_7
11_8

ITU-R F.387-9 Annex 1 - CS(40) - DS(530) - 10.7-11.7


CEPT 12-06 E Rec. 1 - CS(40) - DS(530) - 10.7-11.7

n#
1
2
3
4
5
6
7
8
9
10
11

RF-freq (MHz)
10735
10775
10815
10855
10895
10935
10975
11015
11055
11095
11135

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'

RF-freq (MHz)
11265
11305
11345
11385
11425
11465
11505
11545
11585
11625
11665

11 _9
11_10
11_11
11_12
n#
1
2
3
4
5
6
7
8
9
10
11
12

11_13
n#
1
2
3
4
5
6
7
8
9
10
11
12
13

ITU-R F.387-9 Annex 2 - CS(40) - DS(490) - 10.7-11.7


CEPT 12-06 E Rec. 3 - CS(40) - DS(490) - 10.7-11.7
FCC 101.147 (o-7) - CS(40) - DS(490) - 10.7-11.7
SRSP-310.7 - CS(40) - DS(490) - 10.7-11.7
RF-freq (MHz)
10735
10775
10815
10855
10895
10935
10975
11015
11055
11095
11135
11175

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'

RF-freq (MHz)
11225
11265
11305
11345
11385
11425
11465
11505
11545
11585
11625
11665

FCC 101.147 (o-6) - CS(30/40) - DS(490/530) - 10.7-11.7


RF-freq (MHz)
10715
10755
10795
10835
10875
10915
10955
10995
11035
11075
11115
11155
11185

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'

RF-freq (MHz)
11215
11245
11285
11325
11365
11405
11445
11485
11525
11565
11605
11645
11685

11 _14
n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

11_15
n#
1
2
3
4
5
6

11_16
n#
1
2
3
4
5
6
7
8
9
10
11

SRSP-310.7 - CS(30) - DS(490) - 10.7-11.7


RF-freq (MHz)
10725
10755
10785
10815
10845
10875
10905
10935
10965
10995
11025
11055
11085
11115
11145
11175

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'

RF-freq (MHz)
11215
11245
11275
11305
11335
11365
11395
11425
11455
11485
11515
11545
11575
11605
11635
11665

CS(40) - DS(530) - 10.7-11.5


RF-freq (MHz)
10735
10775
10815
10855
10895
10935

n'#
1'
2'
3'
4'
5'
6'

RF-freq (MHz)
11265
11305
11345
11385
11425
11465

CS(40) - DS(490) - 10.7-11.7


RF-freq (MHz)
10755
10795
10835
10875
10915
10955
10995
11035
11075
11115
11155

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'

RF-freq (MHz)
11245
11285
11325
11365
11405
11445
11485
11525
11565
11605
11645

Frequency Plans
13GHz
13_9
13_10
n#
1
2
3
4
5
6
7
8

ITU-R F.497 - CS(28) - DS(266) - 12.7-13.3


CEPT 12-02 E - CS(28) - DS(266) - 12.7-13.3
RF-freq (MHz)
12765
12793
12821
12849
12877
12905
12933
12961

n'#
1'
2''
3'
4'
5'
6'
7'
8'

RF-freq (MHz)
13031
13059
13087
13115
13143
13171
13199
13227

Frequency Plans
15GHz
15_8

CEPT 12-07E - CS(28) - DS(728) - 14.5-15.35

n#
1
2
3
4

RF-freq (MHz)
14515
14543
14571
14599

n'#
1'
2'
3'
4'

15_10

ITU-R F.636 - CS(28) - DS(490) - 14.4-15.35

n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

RF-freq (MHz)
14417
14445
14473
14501
14529
14557
14585
14613
14641
14669
14697
14725
14753
14781
14809
14837

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'

RF-freq (MHz)
15243
15271
15299
15327

RF-freq (MHz)
14907
14935
14963
14991
15019
15047
15075
15103
15131
15159
15187
15215
15243
15271
15299
15327

15 _12

ITU-R F.636 - CS(28) - DS(420) - 14.5-15.35

n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

RF-freq (MHz)
14515
14543
14571
14599
14627
14655
14683
14711
14739
14767
14795
14823
14851
14879
14907

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'

15_14

ACA - CS(28) - DS(644) - 14.5-15.35

n#
1
2
3
4
5
6
7

RF-freq (MHz)
14515
14543
14571
14599
14627
14655
14683

15_16

Mexico - CS(28) - DS(315) - 14.6-15.2

n#
1
2
3
4
5
6
7
8
9

RF-freq (MHz)
14662
14690
14718
14746
14774
14802
14830
14858
14886

n'#
1'
2'
3'
4'
5'
6'
7'

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'

RF-freq (MHz)
14935
14963
14991
15019
15047
15075
15103
15131
15159
15187
15215
15243
15271
15299
15327

RF-freq (MHz)
15159
15187
15215
15243
15271
15299
15327

RF-freq (MHz)
14977
15005
15033
15061
15089
15117
15145
15173
15201

15 _17

Japan - CS(40) - DS(470) - 14.5-15.2

n#
1
2
3
4

RF-freq (MHz)
14520
14560
14600
14640

15_18

CEPT 12-07E - CS(56) - DS(728) - 14.5-15.35

n#
1
2

RF-freq (MHz)
14529
14585

15_19

Argentina - CS(28) - DS(322) - 14.6-15.2

n#
1
2
3
4
5
6
7
8
9
10

RF-freq (MHz)
14641
14669
14697
14725
14753
14781
14809
14837
14865
14893

n'#
1'
2'
3'
4'

n'#
1'
2'

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'

RF-freq (MHz)
14990
15030
15070
15110

RF-freq (MHz)
15257
15313

RF-freq (MHz)
14963
14991
15019
15047
15075
15103
15131
15159
15187
15215

Frequency Plans
18GHz
18_16
18_17

ITU-R F.595 - CS(27.5) - DS(1010) - 17.7-19.7


CEPT 12-03 E - CS(27.5) - DS(1010) - 17.7-19.7

n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35

RF-freq (MHz)
17727,5
17755
17782,5
17810
17837,5
17865
17892,5
17920
17947,5
17975
18002,5
18030
18057,5
18085
18112,5
18140
18167,5
18195
18222,5
18250
18277,5
18305
18332,5
18360
18387,5
18415
18442,5
18470
18497,5
18525
18552,5
18580
18607,5
18635
18662,5

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16''
17'
18'
19'
20'
21'
22'
23'
24'
25'
26'
27'
28'
29'
30'
31'
32'
33'
34'
35'

RF-freq (MHz)
18737,5
18765
18792,5
18820
18847,5
18875
18902,5
18930
18957,5
18985
19012,5
19040
19067,5
19095
19122,5
19150
19177,5
19205
19232,5
19260
19287,5
19315
19342,5
19370
19397,5
19425
19452,5
19480
19507,5
19535
19562,5
19590
19617,5
19645
19672,5

18_18

China - CS(27.5) - DS(1092.5) - 17.7-19.7

n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

RF-freq (MHz)
17727,5
17755
17782,5
17810
17837,5
17865
17892,5
17920
17947,5
17975
18002,5
18030
18057,5
18085
18112,5
18140
18167,5
18195
18222,5
18250
18277,5
18305
18332,5
18360
18387,5
18415
18442,5
18470
18497,5
18525
18552,5
18580

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16''
17'
18'
19'
20'
21'
22'
23'
24'
25'
26'
27'
28'
29'
30'
31'
32'

RF-freq (MHz)
18820
18847,5
18875
18902,5
18930
18957,5
18985
19012,5
19040
19067,5
19095
19122,5
19150
19177,5
19205
19232,5
19260
19287,5
19315
19342,5
19370
19397,5
19425
19452,5
19480
19507,5
19535
19562,5
19590
19617,5
19645
19672,5

18 _19
18_20

ITU-R F.595 - CS(27.5) - DS(1560) - 17.7-19.7


Norma No 15/96 - CS(27.5) - DS(1560) - 17.7-19.7

n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

RF-freq (MHz)
17727,5
17755
17782,5
17810
17837,5
17865
17892,5
17920
17947,5
17975
18002,5
18030
18057,5
18085
18112,5

18_21

FCC 101.147(r-6) - CS(40) - DS(1560) - 17.7-19.7

n#
1
2
3
4
5
6
7
8
9
10
11

RF-freq (MHz)
17720
17760
17800
17840
17880
17920
17960
18000
18040
18080
18120

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'

RF-freq (MHz)
19287,5
19315
19342,5
19370
19397,5
19425
19452,5
19480
19507,5
19535
19562,5
19590
19617,5
19645
19672,5

RF-freq (MHz)
19280
19320
19360
19400
19440
19480
19520
19560
19600
19640
19680

18 _22

Japan - CS(40) - DS(750) - 17.7-19.7

n#
1
2
3

RF-freq (MHz)
17870
17910
17950

18_23
18_24
n#
1
2
3
4
5
6
7
8

18_25
18_26
n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

n'#
1'
2'
3'

RF-freq (MHz)
18620
18660
18700

ITU-R F.595 - CS(55) - DS(1560) - 17.7-19.7


Norma No 15/96 - CS(55) - DS(1560) - 17.7-19.7
RF-freq (MHz)
17727,5
17782,5
17837,5
17892,5
17947,5
18002,5
18057,5
18112,5

n'#
1'
2'
3'
4'
5'
6'
7'
8'

RF-freq (MHz)
19287,5
19342,5
19397,5
19452,5
19507,5
19562,5
19617,5
19672,5

ITU-R F.595 - CS(55) - DS(1010) - 17.7-19.7


CEPT 12-03 E - CS(55) - DS(1010) - 17.7-19.7
RF-freq (MHz)
17755
17810
17865
17920
17975
18030
18085
18140
18195
18250
18305
18360
18415
18470
18525
18580
18635

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'

RF-freq (MHz)
18765
18820
18875
18930
18985
19040
19095
19150
19205
19260
19315
19370
19425
19480
19535
19590
19645

18 _27

ITU-R F.595 - CS(55) - DS(1010) - 17.7-19.7

n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

RF-freq (MHz)
17810
17865
17920
17975
18030
18085
18140
18195
18250
18305
18360
18415
18470
18525
18580

18 _28

NERA - CS(55) - DS(1010) - 17.7-19.7

n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

RF-freq (MHz)
17768,75
17823,75
17878,75
17933,75
17988,75
18043,75
18098,75
18153,75
18208,75
18263,75
18318,75
18373,75
18428,75
18483,75
18538,75
18593,75
18648,75

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'

RF-freq (MHz)
18820
18875
18930
18985
19040
19095
19150
19205
19260
19315
19370
19425
19480
19535
19590

RF-freq (MHz)
18778,75
18833,75
18888,75
18943,75
18998,75
19053,75
19108,75
19163,75
19218,75
19273,75
19328,75
19383,75
19438,75
19493,75
19548,75
19603,75
19658,75

18 _29

China - CS(55) - DS(1120) - 17.7-19.7

n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

RF-freq (MHz)
17755
17810
17865
17920
17975
18030
18085
18140
18195
18250
18305
18360
18415
18470
18525

18 _31
n#
1
2
3
4
5

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'

RF-freq (MHz)
18875
18930
18985
19040
19095
19150
19205
19260
19315
19370
19425
19480
19535
19590
19645

FCC 101.147(r-7) - CS(80) - DS(1560) - 17.7-19.7


RF-freq (MHz)
17740
17820
17900
17980
18060

n'#
1'
2'
3'
4'
5'

RF-freq (MHz)
19300
19380
19460
19540
19620

Frequency Plans
23GHz
23_12
23_13

ITU-R F.637 Annex 3 - CS(28) - DS(1008) - 22.0-23.6


CEPT 13-02 E - CS(28) - DS(1008) - 22.0-23.6

n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

RF-freq (MHz)
22022
22050
22078
22106
22134
22162
22190
22218
22246
22274
22302
22330
22358
22386
22414
22442
22470
22498
22526
22554

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'

RF-freq (MHz)
23030
23058
23086
23114
23142
23170
23198
23226
23254
23282
23310
23338
23366
23394
23422
23450
23478
23506
23534
23562

23 _14

ITU-R F.637-3 Annex 1 - CS(28) - DS(1232) - 21.2-23.6

n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

RF-freq (MHz)
21238
21266
21294
21322
21350
21378
21406
21434
21462
21490
21518
21546
21574
21602
21630
21658
21686
21714
21742
21770
21798
21826
21854
21882
21910
21938
21966
21994
22022
22050
22078
22106
22134
22162
22190
22218
22246
22274
22302
22330

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'
21'
22'
23'
24'
25'
26'
27'
28'
29'
30'
31'
32'
33'
34'
35'
36'
37'
38'
39'
40'

RF-freq (MHz)
22470
22498
22526
22554
22582
22610
22638
22666
22694
22722
22750
22778
22806
22834
22862
22890
22918
22946
22974
23002
23030
23058
23086
23114
23142
23170
23198
23226
23254
23282
23310
23338
23366
23394
23422
23450
23478
23506
23534
23562

23 _15
23_16

ITU-R F.637 Annex 3 - CS(56) - DS(1008) - 22.0-23.6


CEPT 13-02 E - CS(56) - DS(1008) - 22.0-23.6

n#
1
2
3
4
5
6
7
8
9

RF-freq (MHz)
22078
22134
22190
22246
22302
22358
22414
22470
22526

23_17

RA 352 - CS(56) - DS(1008) - 22.0-23.6

n#
1
2
3
4
5
6
7
8
9
10

RF-freq (MHz)
22036
22092
22148
22204
22260
22316
22372
22428
22484
22540

23_18

ITU-R F.637-3 Annex 1 - CS(56) - DS(1232) - 21.2-23.6

n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

RF-freq (MHz)
21252
21308
21364
21420
21476
21532
21588
21644
21700
21756
21812
21868
21924
21980
22036
22092
22148
22204
22260
22316

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'

RF-freq (MHz)
23086
23142
23198
23254
23310
23366
23422
23478
23534

RF-freq (MHz)
23044
23100
23156
23212
23268
23324
23380
23436
23492
23548

RF-freq (MHz)
22484
22540
22596
22652
22708
22764
22820
22876
22932
22988
23044
23100
23156
23212
23268
23324
23380
23436
23492
23548

23 _20

ITU-R F.637-3 Annex 4 - CS(50) - DS(1200) - 21.2-23.0

n#
1
2
3
4
5
6
7
8
9
10
11
12

RF-freq (MHz)
21225
21275
21325
21375
21425
21475
21525
21575
21625
21675
21725
21775

23_21

ITU-R F.637-3 Annex 4 - CS(50) - DS(1200) - 21.8-23.6

n#
1
2
3
4
5
6
7
8
9
10
11
12

RF-freq (MHz)
21825
21875
21925
21975
22025
22075
22125
22175
22225
22275
22325
22375

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'

RF-freq (MHz)
22425
22475
22525
22575
22625
22675
22725
22775
22825
22875
22925
22975

RF-freq (MHz)
23025
23075
23125
23175
23225
23275
23325
23375
23425
23475
23525
23575

23_25
n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

FCC 101.147(s-6) - CS(50) - DS(1200) - 21.2-23.6


RF-freq (MHz)
21220
21270
21320
21370
21420
21470
21520
21570
21620
21670
21720
21770
21820
21870
21920
21970
22020
22070
22120
22170
22220
22270
22320
22370

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'
21'
22'
23'
24'

RF-freq (MHz)
22420
22470
22520
22570
22620
22670
22720
22770
22820
22870
22920
22970
23020
23070
23120
23170
23220
23270
23320
23370
23420
23470
23520
23570

23 _24
n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

FCC 101.147(s-5) - CS(50) - DS(1200) - 21.2-23.6


RF-freq (MHz)
21235
21285
21335
21385
21435
21485
21535
21585
21635
21685
21735
21785
21835
21885
21935
21985
22035
22085
22135
22185
22235
22285
22335
22385

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'
21'
22'
23'
24'

RF-freq (MHz)
22435
22485
22535
22585
22635
22685
22735
22785
22835
22885
22935
22985
23035
23085
23135
23185
23235
23285
23335
23385
23435
23485
23535
23585

23 _26

FCC 101.147(s-7) - CS(50) - DS(1200) - 21.2-23.6

n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

RF-freq (MHz)
21225
21275
21325
21375
21425
21475
21525
21575
21625
21675
21725
21775
21825
21875
21925
21975
22025
22075
22125
22175
22225
22275
22325
22375

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'
21'
22'
23'
24'

RF-freq (MHz)
22425
22475
22525
22575
22625
22675
22725
22775
22825
22875
22925
22975
23025
23075
23125
23175
23225
23275
23325
23375
23425
23475
23525
23575

Frequency Plans
26GHz
26_3
26_4
n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38

ITU-R F.748 Annex 1 - CS(7) - DS(1008) - 24.25-26.5


CEPT 13-02 E - CS(7) - DS(1008) - 24.25-26.5
RF-freq (MHz)
24552,5
24559,5
24566,5
24573,5
24580,5
24587,5
24594,5
24601,5
24608,5
24615,5
24622,5
24629,5
24636,5
24643,5
24650,5
24657,5
24664,5
24671,5
24678,5
24685,5
24692,5
24699,5
24706,5
24713,5
24720,5
24727,5
24734,5
24741,5
24748,5
24755,5
24762,5
24769,5
24776,5
24783,5
24790,5
24797,5
24804,5
24811,5

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'
21'
22'
23'
24'
25'
26'
27'
28'
29'
30'
31'
32'
33'
34'
35'
36'
37'
38'

RF-freq (MHz)
25560,5
25567,5
25574,5
25581,5
25588,5
25595,5
25602,5
25609,5
25616,5
25623,5
25630,5
25637,5
25644,5
25651,5
25658,5
25665,5
25672,5
25679,5
25686,5
25693,5
25700,5
25707,5
25714,5
25721,5
25728,5
25735,5
25742,5
25749,5
25756,5
25763,5
25770,5
25777,5
25784,5
25791,5
25798,5
25805,5
25812,5
25819,5

39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89

24818,5
24825,5
24832,5
24839,5
24846,5
24853,5
24860,5
24867,5
24874,5
24881,5
24888,5
24895,5
24902,5
24909,5
24916,5
24923,5
24930,5
24937,5
24944,5
24951,5
24958,5
24965,5
24972,5
24979,5
24986,5
24993,5
25000,5
25007,5
25014,5
25021,5
25028,5
25035,5
25042,5
25049,5
25056,5
25063,5
25070,5
25077,5
25084,5
25091,5
25098,5
25105,5
25112,5
25119,5
25126,5
25133,5
25140,5
25147,5
25154,5
25161,5
25168,5

39'
40'
41'
42'
43'
44'
45'
46'
47'
48'
49'
50'
51'
52'
53'
54'
55'
56'
57'
58'
59'
60'
61'
62'
63'
64'
65'
66'
67'
68'
69'
70'
71'
72'
73'
74'
75'
76'
77'
78'
79'
80'
81'
82'
83'
84'
85'
86'
87'
88'
89'

25826,5
25833,5
25840,5
25847,5
25854,5
25861,5
25868,5
25875,5
25882,5
25889,5
25896,5
25903,5
25910,5
25917,5
25924,5
25931,5
25938,5
25945,5
25952,5
25959,5
25966,5
25973,5
25980,5
25987,5
25994,5
26001,5
26008,5
26015,5
26022,5
26029,5
26036,5
26043,5
26050,5
26057,5
26064,5
26071,5
26078,5
26085,5
26092,5
26099,5
26106,5
26113,5
26120,5
26127,5
26134,5
26141,5
26148,5
26155,5
26162,5
26169,5
26176,5

90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128

26_5
26_6
n#
1
2
3
4
5

25175,5
25182,5
25189,5
25196,5
25203,5
25210,5
25217,5
25224,5
25231,5
25238,5
25245,5
25252,5
25259,5
25266,5
25273,5
25280,5
25287,5
25294,5
25301,5
25308,5
25315,5
25322,5
25329,5
25336,5
25343,5
25350,5
25357,5
25364,5
25371,5
25378,5
25385,5
25392,5
25399,5
25406,5
25413,5
25420,5
25427,5
25434,5
25441,5

90'
91'
92'
93'
94'
95'
96'
97'
98'
99'
100'
101'
102'
103'
104'
105'
106'
107'
108'
109'
110'
111'
112'
113'
114'
115'
116'
117'
118'
119'
120'
121'
122'
123'
124'
125'
126'
127'
128'

26183,5
26190,5
26197,5
26204,5
26211,5
26218,5
26225,5
26232,5
26239,5
26246,5
26253,5
26260,5
26267,5
26274,5
26281,5
26288,5
26295,5
26302,5
26309,5
26316,5
26323,5
26330,5
26337,5
26344,5
26351,5
26358,5
26365,5
26372,5
26379,5
26386,5
26393,5
26400,5
26407,5
26414,5
26421,5
26428,5
26435,5
26442,5
26449,5

ITU-R F.748 Annex 1 - CS(14) - DS(1008) - 24.25-26.5


CEPT 13-02 E - CS(14) - DS(1008) - 24.25-26.5
RF-freq (MHz)
24556
24570
24584
24598
24612

n'#
1'
2'
3'
4'
5'

RF-freq (MHz)
25564
25578
25592
25606
25620

6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56

24626
24640
24654
24668
24682
24696
24710
24724
24738
24752
24766
24780
24794
24808
24822
24836
24850
24864
24878
24892
24906
24920
24934
24948
24962
24976
24990
25004
25018
25032
25046
25060
25074
25088
25102
25116
25130
25144
25158
25172
25186
25200
25214
25228
25242
25256
25270
25284
25298
25312
25326

6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'
21'
22'
23'
24'
25'
26'
27'
28'
29'
30'
31'
32'
33'
34'
35'
36'
37'
38'
39'
40'
41'
42'
43'
44'
45'
46'
47'
48'
49'
50'
51'
52'
53'
54'
55'
56'

25634
25648
25662
25676
25690
25704
25718
25732
25746
25760
25774
25788
25802
25816
25830
25844
25858
25872
25886
25900
25914
25928
25942
25956
25970
25984
25998
26012
26026
26040
26054
26068
26082
26096
26110
26124
26138
26152
26166
26180
26194
26208
26222
26236
26250
26264
26278
26292
26306
26320
26334

57
58
59
60
61
62
63
64

26_7
26_8
n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

25340
25354
25368
25382
25396
25410
25424
25438

57'
58'
59'
60'
61'
62'
63'
64'

26348
26362
26376
26390
26404
26418
26432
26446

ITU-R F.748 Annex 1 - CS(28) - DS(1008) - 24.25-26.5


CEPT 13-02 E - CS(28) - DS(1008) - 24.25-26.5
RF-freq (MHz)
24563
24591
24619
24647
24675
24703
24731
24759
24787
24815
24843
24871
24899
24927
24955
24983
25011
25039
25067
25095
25123
25151
25179
25207
25235
25263
25291
25319
25347
25375
25403
25431

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'
17'
18'
19'
20'
21'
22'
23'
24'
25'
26'
27'
28'
29'
30'
31'
32'

RF-freq (MHz)
25571
25599
25627
25655
25683
25711
25739
25767
25795
25823
25851
25879
25907
25935
25963
25991
26019
26047
26075
26103
26131
26159
26187
26215
26243
26271
26299
26327
26355
26383
26411
26439

26 _9
26_10
n#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

ITU-R F.748 Annex 1 - CS(56) - DS(1008) - 24.25-26.5


CEPT 13-02 E - CS(56) - DS(1008) - 24.25-26.5

RF-freq (MHz)
24577
24633
24689
24745
24801
24857
24913
24969
25025
25081
25137
25193
25249
25305
25361
25417

n'#
1'
2'
3'
4'
5'
6'
7'
8'
9'
10'
11'
12'
13'
14'
15'
16'

RF-freq (MHz)
25585
25641
25697
25753
25809
25865
25921
25977
26033
26089
26145
26201
26257
26313
26369
26425

Alarm Lists
Element Alarms
Alarm Name

Alarm Info

Perceived
Severity

Source

SW LICENCE
EXPIRES

One of the licenced features will expire within 10 days, or has already
expired

WARNING

/ne

SW LICENCE
INVALID

Licence file is invalid or corrupt

WARNING

/ne

SW LICENCE
TEMPORARY

All licences are temporary since SU has been replaced

WARNING

/ne

MEN AT WORK

Indication that system is under maintenance

WARNING

/ne

EVENT LOG EXC


The eventlog has exceeded the capacity threshold
LIMIT

WARNING

/ne

SECURITY LOG
EXC LIMIT

Security log has exceeded the capacity threshold

WARNING

/ne

RPS
ORDERWIRE
FAILURE

RPS has lost contact with the other side of the hop

MAJOR

/ne

RPS REMOTE
FAILURE

Remote side failed to execute requested action

MAJOR

/ne

RPS MANUAL
SWITCHING

A manual RPS switching is active

INFO

/ne

RPS CH1 ON
PROTECTION

Channel1 is using the protection channel

INFO

/ne

RPS CH2 ON
PROTECTION

Channel2 is using the protection channel

INFO

/ne

RPS CH3 ON
PROTECTION

Channel3 is using the protection channel

INFO

/ne

RPS CH4 ON
PROTECTION

Channel4 is using the protection channel

INFO

/ne

RPS CH5 ON
PROTECTION

Channel5 is using the protection channel

INFO

/ne

RPS CH6 ON
PROTECTION

Channel6 is using the protection channel

INFO

/ne

RPS CH7 ON
PROTECTION

Channel7 is using the protection channel

INFO

/ne

RPS CH1
ACTIVE Rx

System is receiving on Channel 1 (HSB only)

INFO

/ne

RPS CH2
ACTIVE Rx

System is receiving on Channel 2 (HSB only)

INFO

/ne

RPS CH1
ACTIVE Tx

System is transmitting on Channel 1 (HSB only)

INFO

/ne

RPS CH2
ACTIVE Tx

System is transmitting on Channel 2 (HSB only)

INFO

/ne

RPS SET RX
SWITCH FAILED

Setting of Rx switch failed

MAJOR

/ne/frame-x/ifu/Ch1
(Ch2)

RPS SET TX
MUTE FAILED

Setting of mute Tx signal on ODU failed

MAJOR

/ne/frame-x/slot-x/
ODU

RPS SET AIS


INSERT FAILED

Setting of AIS failed

MAJOR

/ne

RPS SET TX
BRIDGE FAILED

Setting of Tx bridge failed

MAJOR

/ne

RPS CHAN NOT


ALLIGNED

RPS receive switch failure due to no alignment

MAJOR

/ne/frame-x

RPS XMTR BUS


LOC

Loss of Clock on XMTR BUS

MAJOR

/ne

RPS RCVR BUS


LOC

Loss of Clock on RCVR BUS

MAJOR

/ne

SW PACKAGE
DOWNLOAD IN
PROGRESS

Download of SW package to SU

WARNING

/ne

RTC ALARM

The SU has been without power for more than 24 hours and lost the power
WARNING
for the real time clock (RTC), or the RTC has been set to a date in the past

/ne/frame-1/slot-1/su

NO RESPONSE
FROM SNTP
SERVER

When SNTP is enabled, the SU will periodically poll the SNTP-server. If


response is pending the alarm is raised. This indicates that the SNTPserver or the network between the SU and the SNTP-server is down

WARNING

/ne

SNTP STRATUM
EXCEEDED
LEVEL

The SNTP-server supplies a stratum level which is less than the SU


accepts

WARNING

/ne

SNTP STRATUM
UNAVAILABLE

The quality of the time given by the SNTP server is unknown

WARNING

/ne

IFU Alarms
Alarm Name

Alarm Info

Perceived
Severity

Source

ILLEGAL SLOT
POSITION

One or more boards have been placed in an illegal slot position.

WARNING

/NE/frame-x

NEW BOARD
DETECTED

One or more new boards have been inserted into slots where they have
not been configured. The alarm indicates that the housekeeping should
be run in order to configure the new boards

WARNING

/NE/frame-x

IFU METRO Basic Frame Alarms


Alarm Name
LOST CONTACT

Alarm Info
Communication between SU and IFU Basic Frame failed

Perceived
Severity

Source

MAJOR

/ne/frame-x/ifu

POWER FAILURE One or more of the secondary (internal) power sources out of order

WARNING

/ne/frame-x/ifu

SUPPLY POWER
FAILURE

One or more of the primary power sources are missing or out of order

WARNING

/ne/frame-x/ifu

TEST IN
PROGRESS

A test function is enabled on the unit. The test function can be a signal
loop

WARNING

/ne/frame-x/ifu

MAJOR

/ne/frame-x/ifu

CONFIGURATION
Configuration of IFU Basic Frame failed
FAILURE
AIS-INSERT
RX FAILURE

Signal from plug-in unit to IFU Basic Frame missing (transmit direction)
Signal from RIU to IFU Basic Frame missing (receive direction)

CRITICAL
MAJOR

/ne/frame-x/ifu/Ch.1
/ne/frame-x/ifu/Ch.2
/ne/frame-x/ifu/Ch.1
/ne/frame-x/ifu/Ch.2
/ne/frame-x/ifu/Ch.1

LOF

STM-1 / STS-3 Loss Of Frame

CRITICAL

/ne/frame-x/ifu/Ch.2
/ne/frame-x/ifu/Ch.3
/ne/frame-x/ifu/Ch.4
/ne/frame-x/ifu/Ch.1

RS-TIM / TIM-S

Regenerator section trace identifier mismatch

MAJOR

/ne/frame-x/ifu/Ch.2
/ne/frame-x/ifu/Ch.3
/ne/frame-x/ifu/Ch.4

MS-AIS / AIS-L

SDH multiplex section alarm indication signal / SONET Line alarm


indication signal

WARNING

MS-RDI / RDI-L

SDH multiplex section remote defect indication / SONET Line remote


defect indication

WARNING

/ne/frame-x/ifu/Ch.1
/ne/frame-x/ifu/Ch.2
/ne/frame-x/ifu/Ch.1
/ne/frame-x/ifu/Ch.2

IFU XPAND Basic Frame Alarms


Alarm Name
LOST CONTACT

Alarm Info
Communication between SU and IFU Basic Frame failed

Perceived
Severity

Source

MAJOR

/ne/frame-x/ifu

POWER FAILURE One or more of the secondary (internal) power sources out of order

WARNING

/ne/frame-x/ifu

SUPPLY POWER
FAILURE

One or more of the primary power sources are missing or out of order

WARNING

/ne/frame-x/ifu

TEST IN
PROGRESS

A test function is enabled on the unit. The test function can be a signal
loop

WARNING

/ne/frame-x/ifu

CONFIGURATION
Configuration of IFU Basic Frame failed
FAILURE

MAJOR

/ne/frame-x/ifu

RX FAILURE

Signal from RIU to IFU Basic Frame missing (receive direction)

MAJOR

PDH SYNCLOSS
ALARM

OOF after alignment block

CRITICAL

/ne/frame-x/ifu/Ch.1
/ne/frame-x/ifu/Ch.2
/ne/frame-x/ifu/1

SU Alarms
Alarm Name

Alarm Info

Perceived
Severity

Source

SUBUS LINK

Ethernet Link alarm between SU and IFU Basic Frame

MAJOR

/ne/frame-1/slot-1/su

USB
OVERCURRENT

Only when USB Host controller is enabled

WARNING

/ne/frame-1/slot-1/su

MAJOR

/ne/frame-1/slot-1/su

CONFIGURATION
Configuration of SU failed
FAILURE
Additional Alarms when SU Ethernet is enabled
TEST IN
PROGRESS

A test function is established on the unit. The test function can be a signal
WARNING
loop

/ne/frame-1/slot-1/su

MS-AIS / AIS-L

SDH Multiplex Section Alarm Indication Signal / SONET Line Alarm


Indication Signal

WARNING

/ne/frame-1/slot-1/su

MS-RDI / RDI-L

SDH Multiplex Section Remote Defect Indication / SONET Line Remote


Defect Indication

WARNING

/ne/frame-1/slot-1/su

AU-AIS / AIS-P

SDH Administrative Unit Alarm Indication Signal / SONET Path Alarm


Indication Signal

WARNING

/ne/frame-1/slot-1/su

AU-LOP / LOP-P

SDH Administrative Unit Loss of Pointer / SONET STS Loss of Pointer

WARNING

/ne/frame-1/slot-1/su

HP-UNEQ /
UNEQ-P

SDH Higher Order Path received Unequipped signal level / SONET STS
Unequipped

WARNING

/ne/frame-1/slot-1/su

HP-RDI / RDI-P

SDH Higher order Path Remote Defect Indication / SONET STS Path
Remote Defect Indication

WARNING

/ne/frame-1/slot-1/su

HP-TIM / TIM-P

SDH Higher order Path Trace Identifier Mismatch / STS Trace Identifier
Mismatch

MAJOR

/ne/frame-1/slot-1/su

HP-PLM / PLM-P

SDH Higher order Path Payload Label Mismatch / SONET STS Payload
Label Mismatch

WARNING

/ne/frame-1/slot-1/su

GFP- LFD

General Framing Procedure - Loss Of Frame Delineation

WARNING

/ne/frame-1/slot-1/su

LINK LOSS

Traffic Ethernet link down

CRITICAL

/ne/frame-1/slot-1/su

FORCED LINK
LOSS

Traffic Ethernet link is forced down due to remote link loss

MAJOR

/ne/frame-1/slot-1/su

LOC

Signal from IFU Basic Frame to SU is missing

CRITICAL

/ne/frame-1/slot-1/su

OOF

Out Of Frame IFU Basic Frame to SU

CRITICAL

/ne/frame-1/slot-1/su

Additional Alarms when SU Ethernet over PDH is enabled


TEST IN
PROGRESS
GTU-AIS

A test function is established on the unit. The test function can be a signal
WARNING
loop
Group alarm indication signal
WARNING

/ne/frame-1/slot-1/su

GLFA

Group Loss of Alignment

WARNING

/ne/frame-1/slot-1/su

GFP- LFD

General Framing Procedure - Loss Of Frame Delineation

WARNING

/ne/frame-1/slot-1/su

GRAI

Group Remote Defect Indicayion

WARNING

/ne/frame-1/slot-1/su

/ne/frame-1/slot-1/su

LINK LOSS

Traffic Ethernet link down

CRITICAL

/ne/frame-1/slot-1/su

FORCED LINK
LOSS

Traffic Ethernet link is forced down due to remote link loss

MAJOR

/ne/frame-1/slot-1/su

LOC

Signal from IFU Basic Frame to SU is missing

CRITICAL

/ne/frame-1/slot-1/su

OOF

Out Of Frame IFU Basic Frame to SU

CRITICAL

/ne/frame-1/slot-1/su

Additional Alarms when SU Ethernet over Wayside is enabled


TEST IN
PROGRESS

A test function is established on the unit. The test function can be a signal
WARNING
loop

/ne/frame-1/slot-1/su

GFP- LFD

General Framing Procedure - Loss Of Frame Delineation

WARNING

/ne/frame-1/slot-1/su

LINK LOSS

Traffic Ethernet link down

CRITICAL

/ne/frame-1/slot-1/su

FORCED LINK
LOSS

Traffic Ethernet link is forced down due to remote link loss

MAJOR

/ne/frame-1/slot-1/su

LIU Electrical Alarms


The source is given for a LIU placed in slot position x in IFU number x.

Alarm Name
LOST CONTACT

Alarm Info
Communication between SU and LIU failed

Perceived
Severity

Source

MAJOR

/ne/frame-x/slot-x/liu

POWER FAILURE One or more of the secondary (internal) power sources out of order

WARNING

/ne/frame-x/slot-x/liu

TEST IN
PROGRESS

WARNING

/ne/frame-x/slot-x/liu

CONFIGURATION
Configuration of LIU failed
FAILURE

MAJOR

/ne/frame-x/slot-x/liu

LOS

Loss of input signal to LIU

CRITICAL

/ne/frame-x/slot-x/liu

LOF

STM-1/OC-3 Loss Of Frame

MAJOR

/ne/frame-x/slot-x/liu

RS-TIM / TIM-S

Regenerator Section Trace Identifier Mismatch

MAJOR

/ne/frame-x/slot-x/liu

MS-RDI / RDI-L

SDH Multiplex Section Remote Defect Indication / SONET Line Remote


Defect Indication

WARNING

/ne/frame-x/slot-x/liu

MS-AIS / AIS-L

SDH Multiplex Section Alarm Indication Signal / SONET Line Alarm


Indication Signal

WARNING

/ne/frame-x/slot-x/liu

AIS INSERT

AIS inserted towards Line Out

MAJOR

/ne/frame-x/slot-x/liu

A test function is enabled on the unit. The test function can be a signal
loop

LIU Optical Alarms (STM-1/OC-3)


Same as LIU Electrical + laser related alarms
Alarm Name

Alarm Info

Perceived
Severity

Source

Laser OFF

Transmit Laser is turned off

WARNNG

/ne/frame-x/slot-x/liu

LASER FAILURE

Transmit laser failed

CRITICAL

/ne/frame-x/slot-x/liu

Perceived
Severity

Source

LIU Optical Alarms (STM-4/OC-12)


The source is given for a LIU placed in slot position x in IFU number x.
Alarm Name

Alarm Info

MAJOR

/ne/frame-x/slot-x/stm4

POWER FAILURE One or more of the secondary (internal) power sources out of order

WARNING

/ne/frame-x/slot-x/stm4

TEST IN
PROGRESS

WARNING

/ne/frame-x/slot-x/stm4

MAJOR

/ne/frame-x/slot-x/stm4

LOST CONTACT

Communication between SU and LIU failed

A test function is enabled on the unit. The test function can be a signal
loop

CONFIGURATION
Configuration of LIU failed
FAILURE

LOS

Loss of input signal to LIU

CRITICAL

/ne/frame-x/slot-x/stm4

LOF

STM-4/OC-12 Loss Of Frame

MAJOR

/ne/frame-x/slot-x/stm4

RS-TIM / TIM-S

Regenerator Section Trace Identifier Mismatch

MAJOR

/ne/frame-x/slot-x/stm4

MS-RDI / RDI-L

SDH Multiplex Section Remote Defect Indication / SONET Line Remote


Defect Indication

WARNING

/ne/frame-x/slot-x/stm4

MS-AIS / AIS-L

SDH Multiplex Section Alarm Indication Signal / SONET Line Alarm


Indication Signal

WARNING

/ne/frame-x/slot-x/stm4

AIS INSERT

Alarm Indication Signal is inserted in output signal

MAJOR

/ne/frame-x/slot-x/stm4

LOA

Loss of Alignment

MAJOR

/ne/frame-x/slot-x/stm4

LASER OFF

Transmit laser is turned off or SPF module is not present

WARNING

/ne/frame-x/slot-x/stm4

LASER FAILURE

Transmit laser failed

CRITICAL

/ne/frame-x/slot-x/stm4

RIU Alarms
The source is given for a RIU placed in slot position 4 in IFU number x.
Alarm Name

Alarm Info

Perceived
Severity

Source

LOST CONTACT

Communication between SU and RIU failed

MAJOR

/ne/frame-x/slot-4/riu

TEST IN
PROGRESS

A test function is enabled on the unit. The test function can be a signal
loop

WARNING

/ne/frame-x/slot-4/riu

CONFIGURATION
Configuration of RIU failed
FAILURE

MAJOR

/ne/frame-x/slot-4/riu

EW

Estimated Bit Error Rate is above configured threshold

WARNING

/ne/frame-x/slot-4/riu

LBER

Estimated Bit Error Rate is above configured threshold

MINOR

/ne/frame-x/slot-4/riu

HBER

Estimated Bit Error Rate is above configured threshold

MAJOR

/ne/frame-x/slot-4/riu

DEMOD SYNC
LOSS

Demodulator is out of synchronization

MAJOR

/ne/frame-x/slot-4/riu

XCVR LOST
CONTACT

Communication from XCVR to RIU failed

MAJOR

/ne/frame-x/slot-4/riu

TX FAILURE

Missing signal from IFU Basic Frame

MAJOR

/ne/frame-x/slot-4/riu

XCVR POWER
FAILURE

Current exceeding limit on power supply to XCVR

MAJOR

/ne/frame-x/slot-4/riu

EXT AGC AT MAX Signal power level from XCVR to RIU is below limit

MAJOR

/ne/frame-x/slot-4/riu

ADC
OVERRANGE

Signal power level from XCVR to RIU is above limit

MAJOR

/ne/frame-x/slot-4/riu

Signalling between RIUs for XPIC has failed

MAJOR

/ne/frame-x/slot-4/riu

XPIC SYNC LOSS


Only for XPIC
systems

Fan Alarms
Alarm Name

Alarm Info

Perceived
Severity

Source

UNIT MISSING

Fan Unit is missing.

MAJOR

/ne/frame-1/slot-6/fan

FAN ALARM

Combined alarm for the 3 fans on the fan unit. Fan speed is too low

MINOR

/ne/frame-1/slot-6/fan

ODU Alarms
The ODU connected to RIU in Slot No. 4.
Alarm Name

Alarm Info

Perceived
Severity

Source

NEED
ODU configuration is missing
CONFIGURATION

MAJOR

/ne/frame-x/slot-4/odu

LOST CONTACT

Communication between SU and ODU failed

MAJOR

/ne/frame-x/slot-4/odu

TX LO

Transmitter Local Oscillator failure

MAJOR

/ne/frame-x/slot-4/odu

RX LO

Receiver Local Oscillator failure

MAJOR

/ne/frame-x/slot-4/odu

CABLE LOF

Signal from RIU not received properly in the ODU

MAJOR

/ne/frame-x/slot-4/odu

RF OUTPUT
TOO_LOW

Measured RF Output level is below setting

MINOR

/ne/frame-x/slot-4/odu

ATPC LOOP
BROKEN

ATPC feedback signal from remote receiver failed

MINOR

/ne/frame-x/slot-4/odu

RF INPUT LOS

RF input signal level is below critical limit

MAJOR

/ne/frame-x/slot-4/odu

RF INPUT LEVEL

RF input signal level is outside configured range

WARNING

/ne/frame-x/slot-4/odu

RF INPUT LEVEL
SPACE

Space Diversity RF input signal level is outside configured range

WARNING

/ne/frame-x/slot-4/odu

POWER SUPPLY
FAILURE

One or more of the secondary (internal) power sources out of order

MAJOR

/ne/frame-x/slot-4/odu

TEST IN
PROGRESS

A test function is enabled on the unit. The test function can be a signal
loop

WARNING

/ne/frame-x/slot-4/odu

DOWNLOAD IN
PROGRESS

Software is downloaded to the ODU

WARNING

/ne/frame-x/slot-4/odu

Auxiliary 64kb/s Alarms


The source is given for a 64kb/s Unit placed in slot position x in IFU number x
Alarm Name
LOST CONTACT

Alarm Info
Communication between SU and Auxiliary 64kb/s unit failed

Perceived
Severity
MAJOR

Source
/ne/frame-1/slot-x/aux

POWER FAILURE One or more of the secondary (internal) power sources out of order

WARNING /ne/frame-x/slot-x/aux

TEST IN
PROGRESS

WARNING /ne/frame-x/slot-x/aux

A test function is enabled on the unit. The test function can be a


signal loop

CONFIGURATION
Configuration Auxiliary 64kb/s unit failed
FAILURE

MAJOR

/ne/frame-x/slot-x/aux
/ne/frame-x/slot-x/aux/port1
/ne/frame-x/slot-x/aux/port2

OHC LINK LOSS

The internal packet channel has an error

MAJOR

/ne/frame-x/slot-x/aux/port3
/ne/frame-x/slot-x/aux/port4
/ne/frame-x/slot-x/aux/hdlc

Engineering Order Wire (EOW) Alarms


The source is given for a EOW Unit placed in slot position x in IFU number x
Alarm Name
LOST CONTACT

Alarm Info
Communication between SU and EOW Unit failed

Perceived
Severity
MAJOR

Source
/ne/frame-x/slot-x/eow

POWER FAILURE One or more of the secondary (internal) power sources out of order

WARNING /ne/frame-x/slot-x/eow

TEST IN
PROGRESS

WARNING /ne/frame-x/slot-x/eow

A test function is enabled on the unit. The test function can be a


signal loop

CONFIGURATION
Configuration EOW Unit failed
FAILURE

MAJOR

/ne/frame-x/slot-x/eow
/ne/frame-x/slot-x/eow/
port1
/ne/frame-x/slot-x/eow/
port2

/ne/frame-x/slot-x/eow/
port3
/ne/frame-x/slot-x/eow/
port4
/ne/frame-x/slot-x/eow/hdlc

Alarm & Control Unit (ACU) Alarms


The source is given for a EOW Unit placed in slot position x in IFU number x
Alarm Name
LOST CONTACT

Alarm Info
Communication between SU and ACU Unit failed

Perceived
Severity
MAJOR

Source
/ne/frame-x/slot-x/acu

POWER FAILURE One or more of the secondary (internal) power sources out of order

WARNING /ne/frame-x/slot-x/acu

CONFIGURATION
Configuration ACU Unit failed
FAILURE

MAJOR

/ne/frame-x/slot-x/acu

EXTERNAL
ALARM #[1..8]

The n'th alarm input value differs from alarm normal value

User
defined

/ne/frame-x/slot-x/acu

ALARM OUTPUT
#[1..4]

Alarm Output Relay

INFO

/ne/frame-x/slot-x/acu

RELAY #[1..4]
STATE FAILURE

Relay state failure

WARNING /ne/frame-x/slot-x/acu

ADC NOT
CALIBRATED

The unit has not been calibrated. Analogue measurements not valid WARNING /ne/frame-x/slot-x/acu

E1/T1 Wayside Unit Alarms


The source is given for a E1/T1 Wayside Unit placed in slot position x in IFU number x
Alarm Name

Alarm Info

Perceived
Severity

Source

LOST CONTACT

Communication between SU and E1/T1 Wayside Unit failed

MAJOR

/ne/frame-x/slot-x/wayside

POWER FAILURE

One or more of the secondary (internal) power sources out of


order

WARNING /ne/frame-x/slot-x/wayside

TEST IN
PROGRESS

A test function is enabled on the unit. The test function can be a


signal loop or PRBS

WARNING /ne/frame-x/slot-x/wayside

CONFIGURATION
FAILURE

Configuration of E1/T1 Wayside Unit failed

MAJOR

/ne/frame-x/slot-x/wayside

LOS 01
LOS 02

Loss of input signal to E1/T1 Wayside Unit

CRITICAL

/ne/frame-x/slot-x/wayside

AIS-OUT 01
AIS-OUT 02

Alarm Indication Signal in output signal

WARNING /ne/frame-x/slot-x/wayside

AIS-IN 01
AIS-IN 02

Alarm Indication Signal in input signal

WARNING /ne/frame-x/slot-x/wayside

OHC LINK LOSS 01


OHC LINK LOSS 02

The internal packet channel has an error

WARNING /ne/frame-x/slot-x/wayside

Gigabit Ethernet Unit Alarms


The source is given for a Gigabit Ethernet Unit placed in slot position x in IFU number x
Alarm Name
LOST CONTACT

Alarm Info
Communication between SU and Gigabit Ethernet Unit failed

Perceived
Severity
MAJOR

Source
/ne/frame-x/slot-x/giu

POWER FAILURE One or more of the secondary (internal) power sources out of order

WARNING /ne/frame-x/slot-x/giu

TEST IN
PROGRESS

WARNING /ne/frame-x/slot-x/giu

A test function is enabled on the unit. The test function can be a


signal loop

CONFIGURATION
Configuration of the Gigabit Ethernet Unit failed
FAILURE

MAJOR

PORTS
SWAPPED

Ethernet ports in receive direction are swapped. Port 1 to Port 2 and


Port 3 to Port 4/5

WARNING /ne/frame-x/slot-x/giu

VCG-[1..8] DOWN

All members of VCG is down

CRITICAL

/ne/frame-x/slot-x/giu

VCG-[1..8]
DEGRADED

Some members of VCG is down

MAJOR

/ne/frame-x/slot-x/giu

ETH LINK LOSS

Traffic Ethernet link down

CRITICAL

/ne/frame-x/slot-x/giu

FORCED LINK
LOSS

Traffic Ethernet link is forced down due to remote link loss

MAJOR

/ne/frame-x/slot-x/giu

/ne/frame-x/slot-x/giu

E1/T1 Units Alarms


The source is given for a E1 Unit placed in slot position x in IFU number x
Alarm Name
LOST CONTACT

Alarm Info
Communication between SU and E1/T1 Unit failed

Perceived
Severity
MAJOR

Source
/ne/frame-x/slot-x/e1

POWER FAILURE One or more of the secondary (internal) power sources out of order

WARNING /ne/frame-x/slot-x/e1

TEST IN
PROGRESS

WARNING /ne/frame-x/slot-x/e1

A test function is enabled on the unit. The test function can be a


signal loop

CONFIGURATION
Configuration of the E1/T1 Unit failed
FAILURE
LOS 01
LOS 25
AIS 01
AIS 25

MAJOR

/ne/frame-x/slot-x/e1

Loss of E1/T1 input signal

CRITICAL

/ne/frame-x/slot-x/e1/1
/ne/frame-x/slot-x/e1/2
/ne/frame-x/slot-x/e1/3
/ne/frame-x/slot-x/e1/25

Alarm Identification Signal in E1/T1 output signal

/ne/frame-x/slot-x/e1/1
/ne/frame-x/slot-x/e1/2
/ne/frame-x/slot-x/e1/3
WARNING
/ne/frame-x/slot-x/e1/25

DS3/E3 Alarms
The source is given for a DS3/E3 Unit placed in slot position x in IFU number x
Alarm Name

Alarm Info

Perceived
Severity

Source

LOST CONTACT

Communication between SU and DS3/E3 Unit failed

MAJOR

/ne/frame-x/slot-x/ds3-e3

POWER FAILURE

One or more of the secondary (internal) power sources out of


order

WARNING /ne/frame-x/slot-x/ds3-e3

TEST IN PROGRESS

A test function is enabled on the unit. The test function can be


a signal loop

WARNING /ne/frame-x/slot-x/ds3-e3

CONFIGURATION
FAILURE

Configuration of the DS3/E3 Unit failed

MAJOR

/ne/frame-x/slot-x/ds3-e3

LOS 01
LOS 02
LOS 03

Loss of DS3/E3 input signal

CRITICAL

/ne/frame-x/slot-x/ds3-e3

OOF-IN 01
OOF-IN 02
OOF-IN 02

Out Of Frame in input signal (DS3 mode)

WARNING /ne/frame-x/slot-x/ds3-e3

AIS-IN 01
AIS-IN 02
AIS-IN 02

Alarm Indication Signal in input signal

WARNING /ne/frame-x/slot-x/ds3-e3

IDLE-IN 01
IDLE-IN 02
IDLE-IN 02

Idle in input signal (DS3 mode)

WARNING /ne/frame-x/slot-x/ds3-e3

AIS-OUT-INSERTED
01
AIS-OUT-INSERTED
02
AIS-OUT-INSERTED
03

Alarm Indication Signal is inserted in output signal

CRITICAL

OOF-OUT 01
OOF-OUT 02
OOF-OUT 02

Out Of Frame in output signal (DS3 mode)

WARNING /ne/frame-x/slot-x/ds3-e3

AIS-OUT 01
AIS-OUT 02
AIS-OUT 02

Alarm Indication Signal in output signal

WARNING /ne/frame-x/slot-x/ds3-e3

IDLE-OUT 01
IDLE-OUT 02
IDLE-OUT 02

Idle in output signal (DS3 mode)

WARNING /ne/frame-x/slot-x/ds3-e3

/ne/frame-x/slot-x/ds3-e3

Performance Alarms
Alarm Name

G826-B1-15M

Alarm Info

Perceived
Severity

Source

/ne/frame-x/slot-2/liu
The 15 min calculation has exceeded the quality level threshold set
/ne/frame-x/slot-3/liu
for a 15 min calculation. The alarm will not be clared until a complete WARNING
/ne/frame-x/ifu/ch.1
15 min period below threshold occurs
/ne/frame-x/ifu/ch.2

DXC Alarms
VC-4/STS-3c SPE
Alarm Name

Alarm Info

Perceived
Severity

Source

LOST CONTACT

Communication between SU and DXC unit failed

MAJOR

/ne/frame-x/slot-3/dxc

OOF

STM-1 / STS-3 / OC-3 Out Of Frame

MAJOR

/ne/frame-x/slot-3/dxc

LOC

Loss Of Clock

MAJOR

/ne/frame-x/slot-3/dxc

MS-AIS / AIS-L

Multiplex Section Alarm Indication Signal / Line Alarm


WARNING /ne/frame-x/slot-3/dxc
Indication Signal

MS-RDI / RDI-L

Multiplex Section Remote Defect Indication / Line


Remote Defect Indication

WARNING /ne/frame-x/slot-3/dxc

AU-LOP / LOP-P

Administrative Unit Loss of Pointer

WARNING /ne/frame-x/slot-3/dxc

AU-AIS / AIS-P

Administrative Unit Alarm Indication Signal

WARNING /ne/frame-x/slot-3/dxc

HP-LOM

Higher order Path - Loss Of Multi-frame alignment

WARNING /ne/frame-x/slot-3/dxc

HP-UNEQ / UNEQ-P

Higher order Path received Unequipped signal label

WARNING /ne/frame-x/slot-3/dxc

HP-PLM / PLM-P

Higher order Path - Payload Mismatch / STS Path


Label Mismatch

WARNING /ne/frame-x/slot-3/dxc

HP-ERDI / ERDI-P

Higher order Path - Enhanced Remote Defect


Indication

WARNING /ne/frame-x/slot-3/dxc

VC-3/STS-1 SPE
Alarm Name

Alarm Info

Perceived
Severity

Source

LOST CONTACT

Communication between SU and DXC unit failed

MAJOR

/ne/frame-x/slot-3/dxc

OOF

STM-1 / STS-3 / OC-3 Out Of Frame

MAJOR

/ne/frame-x/slot-3/dxc

LOC

Loss Of Clock

MAJOR

/ne/frame-x/slot-3/dxc

MS-AIS / AIS-L

Multiplex Section Alarm Indication Signal / Line Alarm


WARNING /ne/frame-x/slot-3/dxc
Indication Signal

MS-RDI / RDI-L

Multiplex Section Remote Defect Indication / Line


Remote Defect Indication

WARNING /ne/frame-x/slot-3/dxc

AU-LOP / LOP-P

Administrative Unit Loss of Pointer

WARNING /ne/frame-x/slot-3/dxc

AU-AIS / AIS-P

Administrative Unit Alarm Indication Signal

WARNING /ne/frame-x/slot-3/dxc

HP-UNEQ / UNEQ-P

Higher order Path received Unequipped signal label

WARNING /ne/frame-x/slot-3/dxc

HP-PLM / PLM-P

Higher order Path - Payload Mismatch / STS Path


Label Mismatch

WARNING /ne/frame-x/slot-3/dxc

HP-ERDI / ERDI-P

Higher order Path - Enhanced Remote Defect


Indication

WARNING /ne/frame-x/slot-3/dxc

TU-LOP /LOP-V

Loss Of TU Pointer / VT Loss Of Pointer

WARNING /ne/frame-x/slot-3/dxc

TU-AIS / AIS-V

TU / VT Alarm Indication Signal

WARNING /ne/frame-x/slot-3/dxc

LP-PLM / PLM-V

Lower order Path - Payload Mismatch / STS Path


Label Mismatch

WARNING /ne/frame-x/slot-3/dxc

LP-UNEQ /UNEQ-V

Lower order Path - Unequipped

WARNING /ne/frame-x/slot-3/dxc

LP-ERDI / ERDI-V

Lower order Path - Enhanced Remote Defect


Indication

WARNING /ne/frame-x/slot-3/dxc

VC-12
Alarm Name
LOST CONTACT

Alarm Info
Communication between SU and DXC unit failed

Perceived
Severity
MAJOR

Source
/ne/frame-x/slot-3/dxc

OOF

STM-1 / STS-3 / OC-3 Out Of Frame

MAJOR

/ne/frame-x/slot-3/dxc

LOC

Loss Of Clock

MAJOR

/ne/frame-x/slot-3/dxc

MS-AIS / AIS-L

Multiplex Section Alarm Indication Signal / Line Alarm


WARNING /ne/frame-x/slot-3/dxc
Indication Signal

MS-RDI / RDI-L

Multiplex Section Remote Defect Indication / Line


Remote Defect Indication

WARNING /ne/frame-x/slot-3/dxc

AU-LOP / LOP-P

Administrative Unit Loss of Pointer

WARNING /ne/frame-x/slot-3/dxc

AU-AIS / AIS-P

Administrative Unit Alarm Indication Signal

WARNING /ne/frame-x/slot-3/dxc

HP-UNEQ / UNEQ-P

Higher order Path received Unequipped signal label

WARNING /ne/frame-x/slot-3/dxc

HP-PLM / PLM-P

Higher order Path - Payload Mismatch / STS Path


Label Mismatch

WARNING /ne/frame-x/slot-3/dxc

HP-ERDI / ERDI-P

Higher order Path - Enhanced Remote Defect


Indication

WARNING /ne/frame-x/slot-3/dxc

TU-LOP /LOP-V

Loss Of TU Pointer / VT Loss Of Pointer

WARNING /ne/frame-x/slot-3/dxc

TU-AIS / AIS-V

TU / VT Alarm Indication Signal

WARNING /ne/frame-x/slot-3/dxc

LP-PLM / PLM-V

Lower order Path - Payload Mismatch / STS Path


Label Mismatch

WARNING /ne/frame-x/slot-3/dxc

LP-UNEQ /UNEQ-V

Lower order Path - Unequipped

WARNING /ne/frame-x/slot-3/dxc

LP-ERDI / ERDI-V

Lower order Path - Enhanced Remote Defect


Indication

WARNING /ne/frame-x/slot-3/dxc

SETS Alarms
Alarm Name

Alarm Info

Perceived
Severity

Source

SYNCHRONISATION PRIORITY Synchronisation source for T0 with priority 1 is


1
selected by SETS

INFO

/ne/frame-x/slot-3/dxc

SYNCHRONISATION PRIORITY Synchronisation source for T0 with priority 2 is


2
selected by SETS

INFO

/ne/frame-x/slot-3/dxc

SYNCHRONISATION PRIORITY Synchronisation source for T0 with priority 3 is


3
selected by SETS

INFO

/ne/frame-x/slot-3/dxc

SYNCHRONISATION PRIORITY Synchronisation source for T0 with priority 4 is


4
selected by SETS

INFO

/ne/frame-x/slot-3/dxc

SYNCHRONISATION FREE
RUNNING

T0 runs on local oscillator

INFO

/ne/frame-x/slot-3/dxc

SYNCHRONISATION
HOLDOVER

T0 is in Holdover mode

INFO

/ne/frame-x/slot-3/dxc

SYNCHRONISATION T4 PRI 1

Synchronisation source for T4 with priority 1 is


selected by SETS

INFO

/ne/frame-x/slot-3/dxc

SYNCHRONISATION T4 PRI 2

Synchronisation source for T4 with priority 2 is


selected by SETS

INFO

/ne/frame-x/slot-3/dxc

SYNCHRONISATION T4 PRI 3

Synchronisation source for T4 with priority 3 is


selected by SETS

INFO

/ne/frame-x/slot-3/dxc

SYNCHRONISATION T4 PRI 4

Synchronisation source for T4 with priority 4 is


selected by SETS

INFO

/ne/frame-x/slot-3/dxc

INFO

/ne/frame-x/slot-3/dxc

SYNCHRONISATION T4 LOCAL T4 runs on local oscillator

SONET / SDH Mapping structure


In the figures below, the mapping structures of SONET and SDH signals are shown

Mini Balun Termination Procedure


1. Disassemble the rear end components from the mini-balun.
2. Fit the rear outer cover assembly onto the cable, beginning with the smaller end.
3. Strip the cable jacket to 11mm from the end of the cable.

4. Fold the drain wire back and around the cable sheath.

5. Insert the wires into the holes in the smaller end of the stuffer cap.
6. The hole in the protruding section of the stuffer cap corresponds with the polarity of the
centre conductor of the coaxial connector. Ensure that the stuffer cap is pushed hard
against the cable face. Spread the conductors apart towards the sides of the stuffer
cap and fit the conductor ends into the slot in each side of the sfuffer cap.

7. Ensure that the end of each conductor is positioned behind the lip and into the cavity at
the end of the slot as per the illustration.

8. Orient !he tongue on the mini balun to line up with the flat on the stuffer cap and insert
the stuffer cap onto the IDC terminals. Ensure bat he wires are correctly positioned in
the slots. (Refer to point 7 above.)
9. Pull the rear outer assembly forward and align the key to the key into the mini-balun
body. Secure the nut finger tight. Lightly tighten using a 10mm spanner.

Gigabit Ethernet Unit, Ethernet configuration


Configuration table for
Ingress Rate Limiting (IRL). See Gigabit Ethernet Unit, Ethernet page for setting
Flow Control (FC). See Gigabit Ethernet Unit, Ports page for setting
Drop Mode. See Gigabit Ethernet Unit, Ethernet page for setting

Configuration
MODE/Application
TCP Traffic: Ingress Rate Limiting w/FC

Ingress Rate Limiting Drop Mode Flow Control QoS Penalty


ON

Burst Drop

ON

Maximum throughput no QoS

NA

Drop when Ingress


Rate > link capacity

QoS

NA

ON Drop when Ingress


Rate > link capacity

QoS with Ingress Rate Limitting and FC

ON

Burst Drop

ON

ON Not recommended
mode, HOL (Head
Of Line Blocking)

Ingress Rate Limiting: Storm prevention, UDP and


other connection less protocols

ON

Continous
Drop

Ingress Rate Limiting: Storm prevention, TCP/IP QoS


w/Ingress Rate Limiting

ON

Burst Drop

TCP/IP throughput

QoS with Ingress Rate Limiting

ON

Continous
Drop

ON TCP/IP throughput

Abbreviations
AlBlClDlElFlGlHlIlJlKlLlMlNlOlPlQlRlSlTlUlVlWlXlYlZ

A
AC
AGC
AIS
ALC
ANSI
ASIC
ATPC
AUX

Aternating Current
Automatic Gain Control
Alarm Indicating Signal
Automatic Level Control
American National Standards Institute
Application Specified Integrated Circuit
Automatic Transmit Power Control
Auxilliary Unit

B
BB
BER

Baseband
Bit Error Rate

C
CCITT
Clk
CODEC

Comit Consultatif International de Tlgraph et des Tlcommunications (ITU)


Clock
Coder/Decoder

D
DC
DCC
DXC

Direct Current
Data Communication Channel
Digital Cross Connect

E
EMC
EOW
EPROM
ESD
ETSI

Electromagnetic Compability
Engineering Orderwire
Erasable Programmable Read Only Memory
Electrostatic Dischsrge
European Telecommunications Standards Institute

F
FCC

Federal Communications Commission

G
GbE
GND

Gigabit Ethernet Unit


Ground

H
HBER
HDLC
HF

High Bit Error Rate


High-level Data Link Control
High Frequency (3-30 MHz)

I
IF
IFU
ISO
ITU
ITU-R
ITU-T

Intermediate Frequency
Interface Unit
International Organization for Standardization
International Telecom. Union
International Telecom. Union (former CCIR)
International Telecom. Union (former CCITT)

L
LAN
LBER
LCAS
LED
LIU
LLF
LO
LSI

Local Area Network


Low Bit Error Rate
Link Capacity Adjustment Scheme
Light Emitting Diode
Line Interface Unit
Link Loss Forwarding
Local Oscillator
Large Scale Integration

M
MUX

Multiplexer

N
NE
NOH

Network Element
Nera OverHead

O
OHC

OverHead Connections

P
PC
PCB
PLL
PROM
PWR

Personal Computer
Printed Circuit Board
Phase Locked Loop
Programmable Read Only Memory
Power

Q
QoS

Quality of Service

R
RCVR
RF
RIP
RIU
RSSI

Receiver
Radio Frequency
Routing Information Protocol
Radio Interface Unit
Received Signal Strength Indicator

S
SDH
SNCP
SNMP
SNTP
SOH
SONET
SU
SVCE

Synchronous Digital Hierarchy


Simple Network Connection Protection
Simple Network Management Protocol
Simple Network Time Protocol
Section OverHead (ETSI)
Synchronous Optical NETwork
Supervisory Unit
Service Channel Equipment

T
TOH

Transport OverHead (ANSI)

V
VCO
VCXO
VLSI

Voltage Controlled Oscillator


Voltage Controlled crystal Oscillator
Very Large Scale of Integration

W
WAN

Wide Area Network

X
XCVR
XMTR
XO

Transceiver (Transmitter/Receiver)
Transmitter
Crystal Oscillator

Anda mungkin juga menyukai