Vacuum analysis
and measurement

HLT 550

Leak detector SmartTest

Leak detector without backing pump


X Rugged, dependable helium leak detector

HLT 550

with integrated test leak


X For a mains voltage of 100-230 V, 50/60 Hz
X Without internal backing pump,
external backing pump required
X Very easy operation to achieve precise
measuring results
X Optimum adaptation to every application,
simple maintenance
X Analog and digital inputs and outputs
for industrial use
X Durable and industry-tested mass

Dimensions

spectrometer
X Integrated test leak

25

X Bypass option for large test items

304

X For sniffer and vacuum leak detection

119

253
556

25

403
460

General technical data


Smallest detectable leak rate for 4He (according AVS 2.1)
Sniffer probe, detectable leak rate
Detectable gases
Leak rate display
Cold start to ready
Response time
Pumping speed for He
Inlet pressure max.
Ambient temperature
Power consumption
Weight
Input: Analog

Input: Digital

Interface
Output: Analog

Output: Digital

Relay: Switching capacity


Relay: Switching current

PagePage
578 578
Fussleiste Englisch.indd 578

< 510-12 mbar l/s


< 510-8 mbar l/s
4He, 3He, H
2
10-12 - 1 mbar l/s
3 min
0.5 s
2.5 l/s
25 mbar
+10 to +35 C
150 VA
34 kg
ActiveLine
vacuum
transmitter
Start/Stop, Vent,
Cero, Calibration,
Bypass detection
RS-232-C, RS-485
Leakage rate
signal 2x 0-10 V,
lin/log
Ready to start,
Ready to
measure, Leak,
Error, Bypass
valve, Calibration
acknowledge
2x 230 V AC
3A

www.pfeiffer-vacuum.net
www.pfeiffer-vacuum.net
14.08.2008 12:46:49 Uhr

OBJ_DOKU-1083-001.fm Seite 579 Dienstag, 12. August 2008 6:20 06

Roughing pump

HLT 550
100-230 V,
50/60 Hz
DN 25 ISO-KF
Vacuum and
sniffing leak
detection
100-230 V,
50/60 Hz
Without

Order number
HLT 550

PT L02 020

Supply

Accessories
Remote control unit for SmartTest
Remote control unit for SmartTest
Connection cable for remote control unit, 4 m
Extension cable for remote control unit, 8 m
Calibrated test leak
CT 408, He test leak, leak rate approx. 10-8 mbar l/s,
DN 10 ISO-KF
CT 446, He test leak, leak rate adjustable from
10-6 - 10 -4 mbar l/s, DN 10 ISO-KF
Bypass option
Bypass option, with mains cable and German plug
Bypass option, with US plug
Cart for SmartTest
Cart with power connection, 230 VAC
Cart with power connection, 100-120 VAC
Sniffer probe
LP 503, sniffer probe with standard tip, 3 m
LP 505, sniffer probe with standard tip, 5 m
LP 510, sniffer probe with standard tip, 10 m
Sniffer test leak
CL 004, Sniffer test leak, He leak rate approx.
10-4 mbar l/s, He
CL 004, Sniffer test leak, He leak rate approx
10-5 mbar l/s, He
CL 004, Sniffer test leak, He leak rate approx
10-6 mbar l/s, He
CL 002 A Sniffer test leak, gas mixture
He : H2 = 95 % : 5 % leak rate approx. 10-6 mbar l/s
Software for SmartTest
Software for SmartTest helium leak detector
USB Converter to RS-485 interface
Connection cable, plug M12, RJ 45
Other accessories
Centering ring with poral filter, FPM/stainless steel,
DN 25 ISO-KF
Helium pistol
Transport case for SmartTest

www.pfeiffer-vacuum.net
www.pfeiffer-vacuum.net
Fussleiste Englisch.indd 579

PT 445 400
PT 445 401
PT 445 402
Mess- und
Steuergerte

Flange (in)
Test method

B8 116 557
B8 115 580

PT 445 410-T
PT 445 412-T
PT 445 415
PT 445 416
BG 449 207-T
BG 449 208-T
BG 449 209-T
BG 447 704-T
BG 447 705-T
BG 447 706-T
Leak
detection

Technical data

BG 449 025A

PT 882 610-T
PM 061 207-T
PM 051 726-T
PF 117 225-T
BG 512 125-T
PT 445 403

Page
579579
Page
14.08.2008 12:46:49 Uhr

Anda mungkin juga menyukai