11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic
Outline
Context and objectives
Inspected component and flaws to detect
Evaluation of a single element ultrasonic conventional control
Evaluation of the phased array technology
Contribution of the Total Focusing Method (TFM)
Principle
Direct mode imaging
Corner mode imaging
Conclusion
page 2
page 3
h = 70 mm
Rint = 1400mm
hnotch = 10mm
L = 285 mm
Backwall echo
page 4
position 1
0.1dB
Position 1 :
Well detected notch
Corner echo well positioned
position 2
Position 2 :
Poor notch detection (-14 dB)
Bad positioning of the corner echo
-14 dB
The porosities mask the notch located at position 2 but not at position 1.
OL45 inspection with single element probe cannot ensure notch detection
for all positions under the shrinkage cavities network.
page 5
-2 dB
page 6
-1.2 dB
-17dB
-1.2 dB
page 7
A11
S11(t)
Sij(t)
SNN(t)
t11
Aij
ROI
tij
ANN
tNN
point to be imaged
Position 2
Position 1
Echographic
imaging
TFM images
Echographic
images
TFM imaging
page 9
Position 1
LLL
TTT
page 10
Conclusion
Feasibility evaluation of the detection of a backwall breaking notch located in a ferritic cast steel under a midthickness network
Results are valid provided there is sufficient SNR (attenuation and structural noise have not been
simulated)
Experimental study necessary to validate the results
page 11
page 12