Date: 05/17/2012
Page: 1 of 7
Models:
e-STUDIO456 Series
Subject:
Change of CCD (4-line CCD), SYS BD, SLG BD, Inverter Board,
Lens Unit and Harnesses
Overview
The CCD, has been changed due to a change of the CIS (Contact Image Sensor) located on the
CCD Board and change of the scanning light source from a Xenon Lamp to LED. As a result of
this change the SYS Board, SLG Board, Inverter Board, Lens unit and harnesses have also
been changed. The new-style CCD requires different Scan firmware. If the MFP firmware does
not match the type of CCD installed, the MFP will not operate correctly.
Table of Contents
Required Firmware .................................................................................................................... 1
Error Conditions/Recovery with CSI/Firmware Mismatch .......................................................... 1
Identifying Machines With New Components ............................................................................. 2
Identifying New/Old Components............................................................................................... 3
Changed/Added Part Numbers .................................................................................................. 6
Required Firmware
On machines produced since April 2012, the CIS on the CCD Board has been changed from a 3line sensor to a 4-line sensor. Due to the change of CIS, the CCD Board, System Board and
SLG Board have also been changed. To support the new CIS, the System and Scanner firmware
have been changed. Please refer to the following chart:
CCD Type
MFP with new 4-line CCD
MFP with old 3-line CCD
Scan F/W
160S-01 or other non "N"
version
160S-01N or later "N" version
NOTE: The MFP will not operate properly if the incorrect version of firmware is installed.
Copyright-2012 Toshiba America Business Solutions, Inc. (TABS). This publication contains proprietary and confidential
information retained for reference purpose by authorized TABS dealers. Unauthorized use of this information is prohibited.
TABS makes no express or implied warranty, including implied warranties of merchantability for a particular purpose, with regard
to this technical publication and disclaims any claim arising by reason of the possession or use thereof.
CCD Type
4-line CCD
3-line CCD
Recovery Procedure
Update the scanner
firmware to version 160S01 with USB media
Update the scanner
firmware to version160S01N with the Download Jig.
This condition cannot be
corrected with the the usb
media.
NOTE: Installing the incorrect firmware version is not possible when using the Download Jig.
= 3-line CCD
= 4-line CCD
Before Change
After Change
SLG board
Harness
between the
SLG and SYS
boards
Carriage 1
Light source
Xenon lamp
Lamp harness
Carriage 1
Harness Holder
SYS board
Carriage 2
Harness Holder
206L/256/306
356/456
P-I
Before Change
After Change
9-10
6LJ18900000
ASYB-PWA-SYS-160X-S
6LJ18987000
ASYB-PWA-SYS-160S
12-10
6LH61471000
HRNS-SCN-SYS-470X
6LH61466000
HRNS-SCN-SYS-470
12-12
6LJ18922000
ASYB-PWA-SLG-160X-S
6LJ19031000
ASYB-PWA-SLG-160S
12-13
6LH56670000
LENS-UNIT-F470-AI
6LJ15142000 LENS-UNITH16X
END
12-43
D0-29429000
FPC-31-12-WD
---
15-17
6LH64638000
INV-EXPO-470
---
15-18
6LA39548000
COVER-INV
---
15-19
X0-02246000
S/TPP/FHEXM-3X6-NI
---
15-34
---
6LJ18927000
PWA-H-SCNRLY-160
23-1
6LH56622000
CARRIGE-1-F470S
6LJ15168100
CARRIGE-1-H160S
23-2
6LH56554000
HLDR-WH-CRG1-470
6LH56683000
HLDR-WH-CRG1-H16X_N
23-3
6LH64639000
LAMP-EXPO-470
6LJ18968000
LAMP-SCN-LED-160
23-5
6LH56520000
REFLECTOR-470
---
23-7
---
24-1
6LH56623000
CARRIGE-2-F470S
6LJ18967000
HRNS-SCN-LED-160
6LJ15170000
CARRIGE-2-H160S
24-2
6LH56551000
GUIDE-WH-CRG2-470
6LH56685000
GUIDE-WH-CRG2-H16X_N