Bondstrand Product Data

Series 3400 Fiberglass


Epoxy Pipe Systems
for marine applications
using Taper/Taper adhesive-bonded joint
Uses and applications

Performance

Laminate meets all IMO requirements.


Pipe wall design using a 148 N/mm2 Hydrostatic Design Basis (Procedure B.)
A 0.5 mm liner is available on request.
Maximum operating temperature: 93C.
This system is designed to provide minimal 4:1 safety factor in accordance with
IMO Regulations.
Classification: Fire Endurance L3 meets all IMO requirements.

Description

Pipe
Filament-wound fiberglass reinforced epoxy with Taper/Taper male and female
adhesive-bonded joint.

Air cooling circulation water


Auxiliairy equipment cooling
Ballast / segregated ballast
Brine
Drainage / sanitary service / sewage
Eductor service
Electrical conduit
Exhaust piping
Fresh water / saltwater service (non-essential)
Inert gas effluent
Main engine cooling
Sounding pipes / vent lines
Steam condensate
Tank cleaning (saltwater system)

Fittings
Standard filament-wound couplings, 22.5, 45 and 90 Elbows, Tees and Reducing
Tees, Concentric Reducers, Flanges and Nipples. Special fittings are available on
request.
* Flanges are available with the following drillings: ANSI B16.5 Class 150 & 300, DIN,
ISO & JIS. Other drilling patterns are available on request.
For dimensional data and standard configurations for fittings, please refer to the
respective Bondstrand Fittings Guide for Taper/Taper adhesive-bonded joints
(Ref. FP 657-10 to FP 657-25).

Joining systems

*
*
*
*
*

Taper/Taper integral filament-wound male and female adhesive-bonded joint.


Van Stone type flanges with movable flange rings for easy bolt aligment.
Flanges hubless (heavy-duty)
Viking-Johnson, Dresser, Straub or similar type mechanical couplings.
Double O-ring Expansion Joints.

Ameron 1999 FP 835 08/99. Page 1 of 4 - Printed in the Netherlands.

Pipe sizes

Bondstrand pipe is produced in different lengths depending on pipe size and location
of manufacture. Pipe can be cut to specified lengths at the factory.
Consult your Ameron representative for details.
From 50-150 mm (2-6")
From 200-600 m. (8-24")
From 700-1000 mm (28-40")

Physical properties

Mechanical properties

: 6.1 m. random length.


: 6.1 or 12.2 m. random lengths.
: 11.8 m. random length.

Pipe property

Units

Value

Method

Thermal conductivity
Thermal expansivity (lineair)
Flow coefficient
Absolute roughness
Density

W/mK
10-6 mm/mm/C
Hazen-Williams
10-6 m
g/cm 3

.33
18.0
150
5.3
1.8

Ameron
Ameron

Pipe property

Unit

21C

93C

Method

N/mm 2

300

N/mm 2
N/mm 2

Bi-axial
Ultimate hoop stress at weeping
Circumferential
Hoop tensile strength
Hoop tensile modulus
Poisson's ratio axial/hoop
Longitudinal
Axial tensile strength
Axial tensile modulus
Poisson's ratio hoop/axial
Axial bending strength
Beam
Apparent elstic modulus
Hydrostatic Design Basis
Static
Cyclic

ASTM D-1599

300
25300
0.50

22000
0.65

ASTM D-2290
ASTM D-2290
Ameron

N/mm 2
N/mm 2

N/mm 2

65
10000
0.40
80

50
7800
0.45

ASTM D-2105
ASTM D-2105
ASTM D-2105
Ameron

N/mm 2

9200

7000

ASTM D-2925

N/mm 2

148*

N/mm 2

50*

ASTM D-2992
(Proc. B)
ASTM D-2992
(Proc. A)

* a 65C

Typical pipe dimensions

Nominal
Pipe Size

Pipe
ID

Minimal total wall thickness (mm)

(mm)

(in)

(mm)

3410

3412

3414

3416

3420

3425

50
80
100
150
200
250
300
350
400
450
500
600
700
750
800
900
1000

2
3
4
6
8
10
12
14
16
18
20
24
28
30
32
36
40

53.2
81.8
105.2
159.0
208.8
262.9
313.7
344.4
393.7
433.8
482.1
578.6
700.0
750.0
800.0
900.0
1000.0

2.3
2.3
2.3
2.5
3.1
3.5
3.9
4.1
4.4
4.6
5.4
6.0
7.0
7.2
7.4
7.9
8.6

2.3
2.3
2.3
2.7
3.1
3.5
4.1
4.5
4.8
5.5
6.0
7.0
7.6
8.1
8.6
9.6
10.6

2.3
2.3
2.3
2.8
3.3
3.7
4.3
4.9
5.3
5.8
6.5
7.5
9.0
9.7
10.3
11.4
12.7

2.3
2.3
2.5
3.0
3.5
4.3
5.0
5.4
6.1
6.7
7.4
8.7
10.5
11.2
11.9
13.3
14.7

2.3
2.3
2.5
3.4
4.0
4.8
5.7
6.1
7.0
7.6
8.3
10.1

2.3
2.4
2.9
3.9
5.0
6.0
7.1
7.9
8.9
9.7
10.7
12.8

Note: Pipe series designation: First two digits indicate product serie.
final two digits indicate internal pressure class (bar).

Ameron 1999 FP 835 08/99. Page 2 of 4 - Printed in the Netherlands.

External pressure
performance

Pipe weight

Nominal
Pipe Size

Ultimate Collapse (bar) at 21C

(mm)

(in)

3410

3412

3414

3416

3420

3425

50
80
100
150
200
250
300
350
400
450
500
600
700
750
800
900
1000

2
3
4
6
8
10
12
14
16
18
20
24
28
30
32
36
40

24.5
6.7
3.2
1.3
1.2
0.9
0.8
0.7
0.6
0.5
0.7
0.5
0.5
0.5
0.4
0.4
0.3

24.5
6.7
3.2
1.7
1.2
0.9
1.0
1.0
0.8
1.0
0.9
0.9
0.7
0.7
0.7
0.7
0.7

24.5
6.7
3.2
1.9
1.5
1.1
1.1
1.3
1.2
1.2
1.2
1.1
1.1
1.2
1.2
1.1
1.2

24.5
6.7
4.4
2.5
1.9
1.9
1.9
1.8
1.8
1.9
1.9
1.8
1.8
1.8
1.8
1.8
1.8

24.5
6.7
4.4
3.8
3.0
2.8
2.9
2.7
2.9
2.8
2.7
2.9

24.5
7.9
7.5
6.2
6.3
5.8
5.9
6.3
6.1
6.0
6.0
6.1

Nominal
Pipe Size

Minimum weight empty pipe in kg/m

(mm)

(in)

3410

3412

3414

3416

3420

3425

50
80
100
150
200
250
300
350
400
450
500
600
700
750
800
900
1000

2
3
4
6
8
10
12
14
16
18
20
24
28
30
32
36
40

0.7
1.0
1.3
2.1
3.5
5.0
6.7
7.8
9.5
11.0
14.4
19.3
27.3
30.1
33.0
39.7
48.1

0.7
1.0
1.3
2.3
3.5
5.0
7.1
8.6
10.5
13.3
16.1
22.6
29.8
34.0
38.6
48.5
59.6

0.7
1.0
1.3
2.4
3.8
5.3
7.4
9.4
11.6
14.0
17.5
24.3
35.4
41.0
46.4
57.9
71.8

0.7
1.0
1.4
2.6
4.0
6.3
8.7
10.4
13.4
16.3
20.0
28.4
41.5
47.5
53.9
67.8
83.4

0.7
1.0
1.4
3.0
4.6
7.0
10.0
11.8
15.5
18.6
22.6
33.1

0.7
1.1
1.7
3.4
5.9
8.9
12.6
15.4
19.9
23.9
29.4
42.3

Note: Excluding integral joints.

Specific Tangential
Initial Stifness

Nominal
Pipe Size

Specific Tangential Initial Stiffness (STIS) in N/m2 a 21C

(mm)

(in)

3410

3412

3414

3416

3420

3425

50
80
100
150
200
250
300
350
400
450
500
600
700
750
800
900
1000

2
3
4
6
8
10
12
14
16
18
20
24
28
30
32
36
40

73904
21044
10037
4042
3922
3028
2599
2334
1990
1730
2148
1760
1642
1493
1318
1144
1094

73904
21044
10037
5359
3922
3028
3079
3191
2659
3119
3026
2891
2134
2128
2123
2115
2108

73904
21044
10037
6113
4885
3667
3615
4232
3684
3707
3916
3601
3641
3752
3737
3612
3692

73904
21044
13691
7821
5991
6098
5963
5820
5816
5899
5923
5753
5891
5867
5847
5814
5787

73904
21044
13691
12117
9447
8787
9141
8636
9033
8804
8509
9166

73904
24662
23396
19347
19797
18142
18446
19622
19221
18884
18752
19016

Note: Pipe series designation: First two digits indicate product serie.
final two digits indicate internal pressure class (bar).
Ameron 1999 FP 835 08/99. Page 3 of 4 - Printed in the Netherlands.

Span lengths

Nominal
Pipe Size

Partial span recommendations* (in meters) for


horizontal support arrangements at 21C

(mm)

(in)

3410

3412

3414

3416

3420

3425

50
80
100
150
200
250
300
350
400
450
500
600
700
750
800
900
1000

2
3
4
6
8
10
12
14
16
18
20
24
28
30
32
36
40

3.2
3.6
3.8
4.4
5.0
5.4
5.9
6.1
6.4
6.7
7.1
7.7
8.4
8.6
8.8
9.2
9.7

3.2
3.6
3.8
4.4
5.0
5.4
5.9
6.2
6.6
7.0
7.3
8.0
8.6
8.9
9.2
9.7
10.2

3.2
3.6
3.8
4.5
5.0
5.5
6.0
6.4
6.7
7.1
7.5
8.1
8.9
9.3
9.6
10.1
10.7

3.2
3.6
3.9
4.6
5.1
5.7
6.3
6.5
7.0
7.3
7.7
8.4
9.3
9.6
9.9
10.5
11.1

3.2
3.6
3.9
4.7
5.3
5.9
6.5
6.7
7.2
7.6
7.9
8.8

3.2
3.6
4.1
4.9
5.6
6.2
6.8
7.2
7.7
8.0
8.5
9.3

* Note:

1)

2)

For continuous span use of above values: plus 20%


For simple span use of above values: minus 20%
Span recomendations are based on pipes filled with water with a specific
gravity of 1000 kg/m3 and include no provision for weights caused by valves,
flanges or heavy objects.
Span recommendations are calculated for a maximum long time deflection
of 13 mm to ensure good appearance and adequate drainage.

Surge pressure

Maximum allowable surge pressure is 150% of rated pressure.

Pressure testing

Pipe system is designed for field testing with water at 150% of rated pressure.

Conversions

1 psi
1 bar
1 MPa
1 po
1 Btu.po/ft2hF
C

Important notice

This product literature and the recommendations for usage it contains are based on test
data reasonably believed to be reliable. It is intended that this literature be used by
personnel having specialised training in accordance with currently acceptable industry
practice and normal operating conditions. Variation in environment, changes in operating procedures, or extrapolation of data may cause unsatisfactory results. We recommend that your engineers verify the suitability of this product for your intended application.
Since we have no control over the conditions of service, we expressly disclaim responsibility for the results obtained or for any consequential or incidental damages of any kind
incurred

Fiberglass Pipe Group


Headquarters
P.O. Box 801148
Houston TX 77280
U.S.A.
Phone: (+1) 713 690 7777
Fax: (+1) 713 690 2842
Internet:www.ameron.com

Fiberglass Pipe Division


The Americas
P.O. Box 878
Burkburnett, Texas 76364
U.S.A.
Phone: (+1) 940 569 1471
Fax: (+1) 940 569 2764

= 6895 Pa
= 105Pa
= 1 N/mm2

=
=
=
=
=
=

0,07031 kg/cm2
14,5 psi
145 psi
25,4 mm
0,1442 W/mK
5/9 (F-32)

Fiberglass Pipe Division


Europe
Ameron B.V.
P.O. Box 6
4190 CA Geldermalsen
The Netherlands
Phone: (+31) 345-587 587
Fax: (+31) 345 587 561

= 1,02 kg/cm2
= 10,2 kg/cm2

Fiberglass Pipe Division


Asia
Ameron (Pte) Ltd
No. 7A, Tuas Avenue 3
Jurong
Singapore 639407
Phone: (+65) 861 6118
Fax: (+65) 862 1302/861 7834

Anda mungkin juga menyukai