Ref.
EMS58421
DIRECT
INVERSE
Easergy range
VD23
R1
24V-48V
R2
+ -
V1 V2 V3 V0
chn ngun
U
U21U13U32
13 14 15 16 17 18 19 20
VD23
L1
L2
L3
VPIS-VO
DE58731EN
Users manual
Direct
output
Sw 1
Sw 2
%
g
Easer
VD23
Esc
Sw 2
R2
V1+V2+V3
V1 V2 V3
R2
(U)
3 4 5 6
V1+V2+V3+V0
V1 V2 V3
V1+V2+V3
3 4 5 6
3 4 5 6
U12 U13 U23 V0
U12+U13+U23+V0
V1 V2 V3 V0
V1 V2 V3 V0 R1
Inverted
output
Sw 1
(V)
R1
3 4 5 6
Direct
output
Sw 1
3 4 5 6
V1+V2+V3+V0
Inverted
output
Sw 1
3 4 5 6
L1
L2
L3
Product
Voltage detection
relay VD23
R1
R1
U12+U13+U23+V0
R2
U12+U13+U23
U12 U13 U23
R2
3 4 5 6
3 4 5 6
R1
V1+V2+V3
V1 V2 V3
R1
V1 V2 V3
V1+V2+V3
R1
U12+U13+U23
U12 U13 U23
R1
R2
V1+V2+V3
V1 V2 V3
R2
V1 V2 V3
V1+V2+V3
R2
U12+U13+U23
U12 U13 U23
R2
8421
EMS5
3 4 5 6
R1
R2
3 4 5 6
V2
V2
V2
R1
R2
V2
3 4 5 6
V2
V2
V2
V2
3 4 5 6
U13
U13
U13
R1
R2
U13
U13
U13
U13
R1
R2
U13
On relay VD23, functional settings are performed by means of the micro-switches located on the rear panel.
Threshold and time delay settings are performed by means of the buttons on the front panel (see section on
Configuration of thresholds and time delays).
Schneider Electric Industries SAS
Schneider Electric Telecontrol
839 Chemin des Batterses
Z.I. Ouest
01700 St Maurice de Beynost
Tel.: +33 (0)4 78 55 13 13
Fax: +33 (0)4 78 55 50 00
http://www.schneider-electric.com
E-mail: telecontrol@schneider-electric.com
NT00229-FR-EN-02
U
L1
L2
L3
%
Esc
Detection sequence
Voltage presence
indicator
Return
Six micro-switches can be used to define the desired detection mode. All combinations are possible
regarding the phases to be monitored (see table in the Connections and settings section).
For example: b 3 phases and residual: V1 + V2 + V3 + V0
b 3 phases: V1 + V2 + V3 or U12 + U13 + U23
b 1 phase: V0, V1, V2, V3, U12, U13, U23
It also offers the capability for obtaining an inverted position of the output contacts.
The output relays can be time delayed by parameters setup.
Mode selection
Test mode
Product
name
Software
version
3s
3s
V
3s
Line-to-line voltages
3s
V
3s
V
3s
V
3s
Detection of voltage presence: when the voltage percentage becomes greater than the set threshold
for all the configured phases (see table in the Connections and settings section), then the VD23 lights
the voltage presence indicator and activates relay R1 (direct mode) or releases relay R1 (inverted mode).
Time delay T11 can delay lighting of the indicator and activation (direct mode) or release (inverted mode)
of relay R1.
Detection of voltage absence: when the voltage percentage becomes less than the set threshold for all
the configured phases (see table in the Connections and settings section), then the VD23 lights the voltage
absence indicator and activates relay R2 (direct mode) or releases relay R2 (inverted mode).
Time delay T21 can delay lighting of the indicator and activation (direct mode) or release (inverted mode)
of relay R2.
Phase
2
3s
Phase
3
Residual
voltage
inverted
line-to-neutral
direct
not
not
not
not
measured measured measured measured
Voltage
presence
Voltage
absence
Calibration mode
3s
or
Phase
1
line-to-line
b Measuring mode: 3 seconds after calibration, the VD23 displays, by scrolling, the percentages
of the nominal voltage detected on each phase. This is the equipments standard operating mode.
v The percentage is displayed on three digits.
v The cursor(s) position on the left of the display indicates the phase(s) that is (are) displayed (L1, L2 or L3).
The percentage displayed is a measurement over 3 seconds.
v So long as no other mode is activated, the percentages are displayed without interruption
Digits
test
Network frequency
3s
Line-to-neutral voltages
3s
3s
V
V
T22
T21
Measuring
mode
Type of
Relay
measurement output
Parameters setup
mode
To set the parameter
values, see the section
below
b Calibration: at power up, the VD23 automatically detects voltage presence and the network frequency,
and then performs self-calibration.
T11
T12
The and buttons allow navigation in the parameter tree structure in accordance with the following
diagram. At any time, a press on the Esc key (Return) allows you to return to the preceding stage.
Configuration mode
Parameters defined
by micro-switches
Operation
V1
Parameter display
DE58734EN
Given the diversity of network voltages and measuring equipment, it is not possible to display precisely
the voltage of the network on which the VD23 is installed. Display is therefore performed as a percentage
of the measured nominal voltage.
At power up of the device, the VD23 measures the network voltage present and sets that value as
a reference (100%).
Due to this initial calibration, the voltage presence/absence detection thresholds are displayed and
configured as a percentage of the line-to-neutral voltage (V) or the line-to-line voltage (U).
The residual voltage thresholds (V0) are also expressed as a percentage of the line-to-neutral voltage.
V2
Esc
Parameter Confirmation
scrolling
= configurable threshold
V3
Voltage absence
indicator
Easergy
VD23
EMS58421
DE58733EN
DE58732
Description
01-2010
Phase voltage
threshold
to
% of nominal voltage
(10% increments)
Residual voltage
threshold
to
% of nominal voltage
(10% increments)
Activation time
delay R1 (direct)
to
0 to 1 s (0.1s increments)
1 to 21 s (2s increments)
to
0 to 1 s (0.1s increments)
1 to 3 s (0.5s increments)
Phase voltage
threshold
to
% of nominal voltage
(10% increments)
Activation time
delay R2 (direct)
to
0 to 1 s (0.1s increments)
1 to 21 s (2s increments)
to
0 to 1 s (0.1s increments)
1 to 3 s (0.5s increments)
Automatic
calibration
or
Forced
calibration
1s
Raccordements et rglages
DE58735
Rfrences
Rf.
EMS58421
DIRECT
Produit
Relais de dtection
de tension VD23
INVERSE
Gamme Easergy
VD23
R1
24V-48V
R2
+ -
V1 V2 V3 V0
U
U21U13U32
13 14 15 16 17 18 19 20
VD23
L1
L2
L3
VPIS-VO
DE58731FR
Manuel utilisateur
Sortie
directe
Sw 1
Sw 2
%
L1
L2
L3
Esc
g
Easer
VD23
V1 V2 V3 V0 R1
R2
V1+V2+V3
V1 V2 V3
R2
3 4 5 6
(U)
3 4 5 6
V1+V2+V3+V0
V1 V2 V3
V1+V2+V3
3 4 5 6
3 4 5 6
U12 U13 U23 V0
U12+U13+U23+V0
V1 V2 V3 V0
R1
Sortie
inverse
Sw 1
Sw 2
3 4 5 6
V1+V2+V3+V0
Sortie
directe
Sw 1
(V)
3 4 5 6
Sortie
inverse
Sw 1
R1
R1
U12+U13+U23+V0
R2
U12+U13+U23
U12 U13 U23
R2
3 4 5 6
3 4 5 6
R1
V1+V2+V3
V1 V2 V3
R1
V1 V2 V3
V1+V2+V3
R1
U12+U13+U23
U12 U13 U23
R1
R2
V1+V2+V3
V1 V2 V3
R2
V1 V2 V3
V1+V2+V3
R2
U12+U13+U23
U12 U13 U23
R2
8421
EMS5
3 4 5 6
R1
R2
3 4 5 6
V2
V2
V2
V2
R1
R2
3 4 5 6
V2
V2
V2
V2
3 4 5 6
U13
U13
U13
R1
R2
U13
U13
U13
U13
R1
R2
U13
Sur le relais VD23, les rglages fonctionnels seffectuent grce aux micro-interrupteurs situs sur la face arrire.
Les rglages de seuil et de temporisation seffectuent laide des boutons en face avant (voir chapitre
Paramtrages des seuils et des temporisations).
Schneider Electric Industries SAS
Schneider Electric Telecontrol
839 Chemin des Batterses
Z.I. Ouest
01700 St Maurice de Beynost
Tl. : +33 (0)4 78 55 13 13
Fax : +33 (0)4 78 55 50 00
http://www.schneider-electric.com
E-mail : telecontrol@schneider-electric.com
NT00229-FR-EN-02
Squence de dtection
DE58732
U
Le VD23 est un relais de dtection
L1
de prsence et dabsence tension.
L2
Voyant prsence
%
U
L3
Le VD23 utilise le VPIS V2-VO
tension
comme capteur, loption VO tant
Esc
Easergy
ncessaire pour sinterfacer avec le VD23.
Voyant absence
VD23
tension
Une connexion spcifique est prvue pour
le raccordement entre le VPIS et le VD23.
Esc
Le VD23 fonctionne avec une alimentation
Dfilement Validation
Retour
externe 24 ou 48 Vcc (possibilit
paramtres
dalimentation par un T200).
Deux sorties relais sont disponibles :
b R1 = prsence de tension (pour les applications de permutation de sources)
b R2 = absence de tension (pour les applications de verrouillage du sectionneur de terre en prsence de
tension sur le cble).
La diversit des tensions rseau et des quipements de prise de mesure ne permet pas dafficher avec
prcision la tension du rseau sur lequel le VD23 est install. Laffichage est donc effectu en pourcentage
de la tension nominale mesure.
A la mise sous tension de lappareil, le VD23 effectue la mesure de la tension rseau prsente et fixe
cette valeur comme rfrence (100 %).
Grce cette calibration initiale, les seuils de dtection prsence/absence tension saffichent
et se configurent en pourcentage de la tension simple (V) ou de la tension compose (U).
Les seuils de tension rsiduelle (V0) sont galement exprims en pourcentage de la tension simple.
Six micro-interrupteurs permettent de dfinir le mode de dtection dsir. Toutes les combinaisons sont
possibles concernant les phases surveiller (voir le tableau du paragraphe Raccordements et rglages).
Par exemple : b 3 phases et rsiduelle : V1 + V2 + V3 + V0
b 3 phases : V1 + V2 + V3 ou U12 + U13 + U23
b 1 phase : V0, V1, V2, V3, U12, U13, U23
Il fournit de plus la possibilit dobtenir une position inverse des contacts de sortie.
Une temporisation des relais de sortie peut tre obtenue par paramtrage.
14
R1
3s
V
3s
Tensions composes
3s
V
3s
V
17
R2
3s
Dtection de prsence tension : lorsque le pourcentage de tension devient suprieur au seuil rgl pour
toutes les phases configures (voir le tableau du paragraphe Raccordements et rglages), alors le VD23
allume le voyant prsence tension et active le relais R1 (mode direct) ou relche le relais R1 (mode inverse).
Le dlai T11 permet de retarder lallumage du voyant et lactivation (mode direct) ou le relchement
(mode inverse) du relais R1.
Dtection absence tension : lorsque le pourcentage de tension devient infrieur au seuil rgl pour toutes
les phases configures (voir le tableau du paragraphe Raccordements et rglages), alors le VD23 allume
le voyant absence tension et active le relais R2 (mode direct) ou relche le relais R2 (mode inverse).
Le dlai T21 permet de retarder lallumage du voyant et lactivation (mode direct) ou le relchement
(mode inverse) du relais R2.
T22
T21
18
Voyant U
Voyant U
Les boutons et permettent de naviguer dans larborescence des paramtres suivant le diagramme
ci-dessous. A tout moment, un appui sur la touche Esc (Retour) permet de revenir ltape prcdente.
Slection
des modes
Mode Test
Mode
Mesure
Nom
produit
Version
logiciel
DE58734FR
3s
Mode Configuration
Paramtres dfinis par
les micro-interrupteurs
Mode Paramtrage
Pour rgler les valeurs
des paramtres voir
le chapitre ci-dessous
3s
3s
ou
3s
Sortie
relais
Phase
1
Phase
2
Phase
3
Tension
rsiduelle
compose
inverse
mesure
mesure
mesure
mesure
simple
directe
non
mesure
non
mesure
non
mesure
non
mesure
Prsence
tension
Absence
tension
Mode Calibration
Test des
digits
Frquence du rseau
Type de
mesure
3s
V
T11
T12
15
b Mode Mesure : 3 secondes aprs la calibration, le VD23 affiche par dfilement, les pourcentages de la
tension nominale dtecte sur chaque phase. Cest le mode de fonctionnement par dfaut de lquipement.
v Laffichage du pourcentage seffectue sur trois digits.
v La position du (des) curseur(s) sur la gauche de lafficheur indique la (les) phase(s) qui est (sont) mesure(s)
(L1, L2 ou L3). Le pourcentage affich est une mesure sur 3 secondes.
v Tant quun autre mode nest pas activ, laffichage des pourcentages est effectu de faon ininterrompue
3s
V
V2
V1
Tensions simples
3s
V
= seuil paramtrable
V3
EMS58421
Fonctionnement
DE58733FR
Prsentation
01-2010
Seuil tension
phases
% de la tension nominale
(pas de 10 %)
Seuil tension
rsiduelle
% de la tension nominale
(pas de 10 %)
Dlai activation
R1 (direct)
0 1 s (pas de 0,1 s)
1 21 s (pas de 2 s)
Dlai relchement
R1 (direct)
0 1 s (pas de 0,1 s)
1 3 s (pas de 0,5 s)
Seuil tension
phases
% de la tension nominale
(pas de 10 %)
Dlai activation
R2 (direct)
0 1 s (pas de 0,1 s)
1 21 s (pas de 2 s)
Dlai relchement
R2 (direct)
0 1 s (pas de 0,1 s)
1 3 s (pas de 0,5 s)
Calibration
automatique
ou
Calibration
force
1s