Anda di halaman 1dari 12

Get the Right GC for Your Industry

Shimadzu was founded on the basis of "Technology for


Science" and we continue to take the initiative in the
analytical technology industry. From our absorption
spectrophotometers to our structure and surface analyzers
and chromatographs, our high-quality products are the
fruits of our original technologies.
As a wholly-owned subsidiary of Shimadzu Corporation,
established in 1875, Shimadzu Scientific Instruments, Inc.
continues to discover cutting-edge technologies to meet
customer needs and requirements that result in the
development of future instrumentation targeted at
Solutions for Science.
At SSI, you, the customer, are our number one priority
and we believe that quality is our responsibility.

SHIMADZU EUROPE LTD., OPERATION CENTER


Albert-Hahn-Strasse 6-10, D-47269 Duisburg, F.R. Germany
Phone: 49(203)7687-0
FAX: 49(203)7666-25
SHIMADZU SCIENTIFIC INSTRUMENTS, INC.
7102 Riverwood Drive, Columbia, MD 21046, USA
Phone: 410-381-1227 or 800-477-1227
FAX: 410-381-1222
http://www.ssi.shimadzu.com
SHIMADZU CORPORATION, International Marketing Division
3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo 101, Japan
Phone: 81(3)3219-5641
FAX: 81(3)3219-5710
Cable Add.: SHIMADZU TOKYO
Overseas Telex No.: 0232-3291 (Answer Code: SHMDT J)
http://www.shimadzu.co.jp

SHIMADZU (ASIA PACIFIC) PTE LTD.


16 Science Park Drive #01-01 Singapore Science Park,
Singapore 118227,
Republic of Singapore
Phone: 65-778-6280
FAX: 65-779-2935
SHIMADZU SCIENTIFIC INSTRUMENTS (OCEANIA) PTY LTD.
Rydalmere Business Park, Unit T, 10-16 South Street,
Rydalmere N.S.W. 2116, Australia
Phone: 61(2)9684-4200
FAX: 61(2)9684-4055

www.ssi.shimadzu.com

Table of Contents

Shimadzu began building Gas


Chromatography products in 1955 and
remains committed to building the best
GC products in the world. Throughout
our long history, the customer's needs
have always been central to all our design,
manufacturing, and testing processes.
As part of this continuing commitment,
we developed the System GC program,
which provides our customers with the
best applicated and fully configured GC
products available anywhere. Configured
and tested in Shimadzu's System
Integration Technology Lab, the system is
shipped with proof of performance,
QA/QC and a field test standard.
Upholding the Shimadzu tradition, the
System GC group is uncompromising in
the quest for excellence and in optimizing
separations and making the products easy
to use.
Expect performance, quality and value
with System GC!

Order your
System GC today!
Call 1-800-477-1227 or log-on
to www.ssi.shimadzu.com
for more information.

Hydrocarbon Processing Analyzers

GC-14A LPG Analyzer .......................................................................... 9

Specialty Gas Analyzers

GC - 8AIT Natural Gas Analyzer #1 .................................................... 2

GC-2010 Simulated Distillation Analyzer ............................................ 9

GC-14A Nitrous Oxide Analyzer ........................................................ 15

GC - 8AIT Natural Gas Analyzer #2 .................................................... 2

GC-17A Simulated Distillation Analyzer .............................................. 9

GC-8A Nitrous Oxide Analyzer .......................................................... 15

GC-14A Natural Gas Analyzer #3 ........................................................ 2

GC-2010 PIANO Analyzer.................................................................... 9

GC-2010 Natural Gas Analyzer by GPA Standard.............................. 2

GC-8A Chlorine Gas Analyzer 1


by ASTM D 1746 .......................................................................... 15

GC-17A PIANO Analyzer .................................................................. 10

GC-17A Natural Gas Analyzer by GPA Standard ................................ 2

GC-2010 DHA Analyzer .................................................................... 10

GC-8A Chlorine Gas Analyzer 2


by ASTM D 1746 .......................................................................... 15

GC-14A Natural Gas Analyzer by GPA Standard ................................ 2

GC-17A DHA Analyzer ...................................................................... 10

GC-17A Specialty Gas Analyzer 1...................................................... 16

GC-2010 Natural Gas Analyzer by


GPA Standard with Fixed Gas Separation ...................................... 3

GC-2010 Oxygenates in Gasoline by ASTM D 4815 ........................ 10

GC-17A Specialty Gas Analyzer 2 ......................................................16

GC-17A Oxygenates in Gasoline by ASTM D 4815 .......................... 11


GC-14A Natural Gas Analyzer by
GPA Standard with Fixed Gas Separation ...................................... 3

GC-17A H2 Contaminants Analyzer....................................................17

GC-14A Oxygenates in Gasoline by ASTM D 4815 .......................... 11

GC-14A H2 Contaminants Analyzer....................................................17

GC-2010 Natural Gas Analyzer by ASTM D 1945 .............................. 4

GC-2010 Refinery Gas by UOP 539 .................................................. 11

GC-8A H2 Contaminants Analyzer......................................................17

GC-17A Natural Gas Analyzer by ASTM D 1945 ................................ 4

GC-2010 Fast Refinery Gas ................................................................ 12

GC-17A N2 Contaminants Analyzer .................................................. 17

GC-14A Natural Gas Analyzer by ASTM D 1945 ................................ 4

GC-2010 ASTM D 2504 Analyzer ...................................................... 12

GC-14A N2 Contaminants Analyzer ................................................ 17

GC-2010 Extended Natural Gas Analyzer .......................................... 4

GC-17A ASTM D 2504 Analyzer ........................................................ 12

GC-8A N2 Contaminants Analyzer ....................................................17

GC-17A Extended Natural Gas Analyzer ............................................ 5

GC-14A ASTM D 2504 Analyzer ........................................................ 12

Environmental and Safety

GC-14A Extended Natural Gas Analyzer ............................................ 5

GC-2010 ASTM D 2505 Analyzer ...................................................... 12

GC-17A TOGAS ..................................................................................18

GC-2010 Natural Gas and Gaseous Fuels


Sulfur Analyzer by ASTM D 5504.................................................... 5

GC-17A ASTM D 2505 Analyzer ........................................................ 12

GC-14A TOGAS ..................................................................................18

GC-14A ASTM D 2505 Analyzer ........................................................ 12

GC-14A Greenhouse Gas Analyzer ....................................................18

GC-2010 ASTM D 3606 Analyzer ...................................................... 13

GC-17A Mine Gas Analyzer .............................................................. 18

GC-17A ASTM D 3606 Analyzer ........................................................ 13

GC-14A Mine Gas Analyzer .............................................................. 18

GC-14A ASTM D 3606 Analyzer ........................................................ 13

GC-14A Mud Logging, Well Gas Sampling Analyzer ........................ 18

GC-2010 Light Petroleum Sulfur Analyzer by ASTM D 5623 .............. 6

GC-2010 Sulfur and Fixed Gas Analyzer .......................................... 13

GC-14A Fuel Cell Analyzer ................................................................ 19

GC-17A Light Petroleum Sulfur Analyzer by ASTM D 5623................ 6

GC-17A Sulfur and Fixed Gas Analyzer ............................................ 13

GC-2010 Methane in Exhaust Analyzer by SAE J1511 .................... 19

GC-14A Light Petroleum Sulfur Analyzer by ASTM D 5623................ 7

GC-14A Sulfur and Fixed Gas Analyzer ............................................ 13

GC-17A Methane in Exhaust Analyzer by SAE J1511 ...................... 19

GC-2010 Natural Gas and Gaseous Fuels


Sulfur Analyzer by ASTM D 6228.................................................... 7

GCMS QP-2010 Aromatics in Gasoline by ASTM D 5769 ................ 13

GC-14A Methane in Exhaust Analyzer by SAE J1511 ...................... 19

GC-17A Natural Gas and Gaseous Fuels


Sulfur Analyzer by ASTM D 5504.................................................... 5
GC-14A Natural Gas and Gaseous Fuels
Sulfur Analyzer by ASTM D 5504.................................................... 5

GC-17A Natural Gas and Gaseous Fuels


Sulfur Analyzer by ASTM D 6228.................................................... 8
GC-14A Natural Gas and Gaseous Fuels
Sulfur Analyzer by ASTM D 6228 .................................................. 8
GC-17A LPG Analyzer by GPA Standard ............................................ 8

GCMS QP-5000 Aromatics in Gasoline by ASTM D 5769 ................ 14


GC-2010 Aromatics in Finished Gasoline by ASTM D 4420 ............ 14
GC-14A Aromatics in Finished Gasoline by ASTM D 4420 .............. 14

Hydrocarbon Processing Analyzers


GC - 8AIT Natural Gas Analyzer #1
Method: ASTM 1945 & 3588
Part Number: 220-90464-00
Analytes: C6+, C1-C5, O2, N2, CO2
Detectors: TCD
Columns: 6 packed
3 valves
This system is fully configured with a CR8A data processor prepared for operation at the factory. Each system is a turnkey analyzer for performing natural gas assays of the components listed
with Compressibility, BTU and Specific Gravity calculations provided for the appropriate compounds. Analysis time approximately
18 minutes. In most cases, He and H2 are either not present or
present in such small quantities that these need not be determined.

GC - 8AIT Natural Gas Analyzer #2


Method: GPA 2261
Part Number: 220-90464-01
Analytes: C6+, N2/air, CH4, CO2, C2, H2S, C3-C5
Detectors: TCD
Columns: 4 packed
1 valve
This system is fully configured with a CR8A data processor prepared for operation at the factory. Each system is a turnkey analyzer for performing natural gas assays of the components listed
with Compressibility, BTU and Specific Gravity calculations provided for the appropriate compounds. Analysis time approximately
18 minutes. In most cases, He and H2 are either not present or
present in such small quantities that these need not be determined.

GC-14A Natural Gas Analyzer #3


Method: ASTM 1945
Part Number: 220-90850-00
Analytes: C6+, C3-C5, CO2, C2, O2, N2, CH4
Detectors: FID/TCD
Columns: 7 packed
4 valves
This turnkey system for natural gas incorporates a C6+ backflush
and analyzes C3-C5 on the FID in that order. The valve timing then
allows for CO2, C2, O2, N2 and CH4 to be detected on the TCD
respectfully. Must include a data station or data processor.
Compressibility, BTU and Specific Gravity calculations can be provided for the appropriate compounds. Analysis time approximately
60 minutes. In most cases, He and H2 are either not present or
present in such small quantities that these need not be determined.

To order call 1-800-477-1227

GC-2010 Natural Gas Analyzer


by GPA Standard

GC-2010 Natural Gas Analyzer by GPA Standard


with Fixed Gas Separation

GC-14A Natural Gas Analyzer by GPA Standard with


Fixed Gas Separation

Method: GPA 2261


Part Number: 220-90851-20
Analytes: C6+, N2/air, CH4, CO2, C2, H2S, C3-C5
Detectors: TCD
Columns: 3 packed
1 valve
This turnkey system is constructed according to The Gas Processors
Association. C6+ components are grouped into a single peak using
a pre-cut column, which is backflushed to elute the hexanes and
heavier as the first peak. Nitrogen/air, methane, carbon dioxide
and ethane through n-pentane elute on forward flow of carrier gas
through the partition column. Analysis time is approximately 18
minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined.
Must include a data processor or data station.

Method: GPA 2261


Part Number: 220-90852-20
Analytes: TCD1 - C6+, N2/air, CH4, CO2, C2, H2S, C3-C5
TCD2 - H2, O2, N2, CH4, CO
Detectors: 2 TCDs
Columns: 5 packed
2 valves
This turnkey system is constructed according to The Gas Processors
Association. C6+ components are grouped into a single peak using
a pre-cut column, which is backflushed to elute the hexanes and
heavier as the first peak. Nitrogen/air, methane, carbon dioxide
and ethane through n-pentane elute on forward flow of carrier gas
through the partition column, which is detected by the first TCD2010. The second gas sampling valve directs the natural gas sample
to a molecular sieve 13X for separation of H2, O2, N2, CH4, CO
which is detected by the second TCD-2010. Analysis time is approximately 18 minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be
determined. Must include a data processor or data station.

Method: GPA 2261


Part Number: 220-90852-14
Analytes: TCD sample side - C6+, N2/air, CH4, CO2, C2, H2S,
C3-C5 TCD reference - H2, O2, N2, CH4, CO
Detectors: TCD using sample and reference
Columns: 5 packed
2 valves
This turnkey system is constructed according to The Gas Processors
Association. C6+ components are grouped into a single peak using
a pre-cut column, which is backflushed to elute the hexanes and
heavier as the first peak. Nitrogen/air, methane, carbon dioxide
and ethane through n-pentane elute on forward flow of carrier gas
through the partition column, which is detected by the sample side
of the TCD-14A. The second gas sampling valve directs the natural gas sample to a molecular sieve 13X for separation of H2, O2,
N2, CH4, CO which is detected by the reference side of the TCD14A . Analysis time is approximately 18 minutes. In most cases, He
and H2 are either not present or present in such small quantities
that these need not be determined. Must include a data processor or data station.

GC-17A Natural Gas Analyzer


by GPA Standard
Method: GPA 2261
Part Number: 220-90851-17
Analytes: C6+, N2/air, CH4, CO2, C2, H2S, C3-C5
Detectors: TCD
Columns: 3 packed
1 valve
This turnkey system is constructed according to The Gas Processors
Association. C6+ components are grouped into a single peak using
a pre-cut column, which is backflushed to elute the hexanes and
heavier as the first peak. Nitrogen/air, methane, carbon dioxide
and ethane through n-pentane elute on forward flow of carrier gas
through the partition column. Analysis time is approximately 18
minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined.
Must include a data processor or data station.

GC-14A Natural Gas Analyzer


by GPA Standard
Method: GPA 2261
Part Number: 220-90851-14
Analytes: C6+, N2/air, CH4, CO2, C2, H2S, C3-C5
Detectors: TCD
Columns: 3 packed
1 valve
This turnkey system is constructed according to The Gas Processors
Association. C6+ components are grouped into a single peak using
a pre-cut column, which is backflushed to elute the hexanes and
heavier as the first peak. Nitrogen/air, methane, carbon dioxide
and ethane through n-pentane elute on forward flow of carrier gas
through the partition column. Analysis time is approximately 18
minutes. In most cases, He and H2 are either not present or present in such small quantities that these need not be determined.
Must include a data processor or data station.

Natural Gas Analyzers by GPA Standard with Fixed Gas Separation

www.ssi.shimadzu.com

GC-2010 Natural Gas Analyzer


by ASTM D 1945

GC-14A Natural Gas Analyzer


by ASTM D 1945

Method: ASTM 1945


Part Number: 220-90853-20
Analytes: C6+, C3-C5, CO2, C2, O2, N2, CH4
Detectors: TCD
Columns: 4 packed
3 valves
The three-valve GC system is widely used for the routine analysis
of natural gas. Basically the same as method GPA 2261, this turnkey
analyzer groups C6+ components into a single peak using a precut column, which is backflushed to elute the hexanes and heavier as the first peak. The valve timing then allows for C3-C5, carbon
dioxide, ethane, oxygen, nitrogen, and methane to elute to the
TCD-2010 in that order. The final analysis time is approximately 2030 minutes. In most cases, He and H2 are either not present or
present in such small quantities that these need not be determined.
Must include a data processor or data station.

Method: ASTM 1945


Part Number: 220-90853-14
Analytes: C6+, C3-C5, CO2, C2, O2, N2, CH4
Detectors: TCD
Columns: 4 packed
3 valves
The three-valve GC system is widely used for the routine analysis
of natural gas. Basically the same as method GPA 2261, this turnkey
analyzer groups C6+ components into a single peak using a precut column, which is backflushed to elute the hexanes and heavier
as the first peak. The valve timing then allows for C3-C5, carbon
dioxide, ethane, oxygen, nitrogen, and methane to elute to the
TCD-14A in that order. The final analysis time is approximately 2030 minutes. In most cases, He and H2 are either not present or
present in such small quantities that these need not be determined.
Must include a data processor or data station.

GC-17A Natural Gas Analyzer


by ASTM D 1945

GC-2010 Extended Natural Gas Analyzer

Method: ASTM 1945


Part Number: 220-90853-17
Analytes: C6+, C3-C5, CO2, C2, O2, N2, CH4
Detectors: TCD
Columns: 4 packed
3 valves
The three-valve GC system is widely used for the routine analysis
of natural gas. Basically the same as method GPA 2261, this turnkey
analyzer groups C6+ components into a single peak using a precut column, which is backflushed to elute the hexanes and heavier as the first peak. The valve timing then allows for C3-C5, carbon
dioxide, ethane, oxygen, nitrogen, and methane to elute to the
TCD-17A in that order. The final analysis time is approximately 2030 minutes. In most cases, He and H2 are either not present or
present in such small quantities that these need not be determined.
Must include a data processor or data station.

Part Number: 220-90854-20


Analytes: separate all components
Detectors: TCD/FID
Columns: 3 packed, 1 capillary
2 valves
A detailed compositional analysis is often required to provide a
better evaluation of the oil and natural gas field. The 2-valve Natural
Gas Extended Analysis System traps O2, N2, CH4, CO onto a
molecular sieve column and allows the separation of CO2, H2S,
and C2 on a porous polymer column for detection to a TCD-2010.
The 10-port sampling valve is set back to the load position which
allows the other hydrocarbons to be loaded on an SPL-2010 injector in the split mode. The hydrocarbons are separated by a PIANO
capillary column for detection by an FID-2010. Analysis time varies
depending on the particular specifications set by the operator. In
most cases, He and H2 are either not present or present in such
small quantities that these need not be determined. Must include
a data processor or data station.

GC-17A Extended Natural Gas Analyzer


Part Number: 220-90854-17
Analytes: separate all components
Detectors: TCD/FID
Columns: 3 packed, 1 capillary
2 valves
A detailed compositional analysis is often required to provide a
better evaluation of the oil and natural gas field. The 2-valve Natural
Gas Extended Analysis System traps O2, N2, CH4, CO onto a
molecular sieve column and allows the separation of CO2, H2S,
and C2 on a porous polymer column for detection to a TCD-17A.
The 10-port sampling valve is set back to the load position which
allows the other hydrocarbons to be loaded on an SPL-17A injector in the split mode. The hydrocarbons are separated by a PIANO
capillary column for detection by an FID-17A. Analysis time varies
depending on the particular specifications set by the operator. In
most cases, He and H2 are either not present or present in such
small quantities that these need not be determined. Must include
a data processor or data station.

GC-14A Extended Natural Gas Analyzer


Part Number: 220-90854-14
Analytes: separate all components
Detectors: TCD/FID
Columns: 3 packed, 1 capillary
2 valves
A detailed compositional analysis is often required to provide a
better evaluation of the oil and natural gas field. The 2-valve Natural
Gas Extended Analysis System traps O2, N2, CH4, CO onto a
molecular sieve column and allows the separation of CO2, H2S,
and C2 on a porous polymer column for detection to a TCD-14A.
The 10-port sampling valve is set back to the load position which
allows the other hydrocarbons to be loaded on an SPL-14A injector in the split mode. The hydrocarbons are separated by a PIANO
capillary column for detection by an FID-14A. Analysis time varies
depending on the particular specifications set by the operator. In
most cases, He and H2 are either not present or present in such
small quantities that these need not be determined. Must include
a data processor or data station.

GC-2010 Natural Gas and Gaseous Fuels Sulfur


Analyzer by ASTM D 5504

GC-2010 with AOC20i Autoinjector


and AOC20s 150 Sample Carousel

To order call 1-800-477-1227

Method: ASTM 5504


Part Number: 220-90855-20
Analytes: Sulfur Compounds
Detectors: SCD/FID
Columns: 2 capillary
1 valve
This turnkey system is designed for the determination of individual volatile sulfur-containing compounds in gaseous fuels including natural gas. It consists of a 10-port sampling valve with 2 sample
loops, a SPL-2010 and 2 capillary columns that are in parallel. The
sulfur compounds are detected by a sulfur chemiluminescence
detector and a FID-2010. The detection range is 0.01 to
1000mg/m3 based upon the analysis of a 1-cm3 sample. Must
include a data processor or data station.

GC-17A Natural Gas and Gaseous Fuels Sulfur


Analyzer by ASTM D 5504
Method: ASTM 5504
Part Number: 220-90855-17
Analytes: Sulfur Compounds
Detectors: SCD/FID
Columns: 2 capillary
1 valve
This turnkey system is designed for the determination of individual volatile sulfur-containing compounds in gaseous fuels including natural gas. It consists of a 10-port sampling valve with 2 sample
loops, an SPL-17A and 2 capillary columns that are in parallel. The
sulfur compounds are detected by a sulfur chemiluminescence
detector and an FID-17A. The detection range is 0.01 to
1000mg/m3 based upon the analysis of a 1-cm3 sample. Must
include a data processor or data station.

GC-14A Natural Gas and Gaseous Fuels Sulfur


Analyzer by ASTM D 5504
Method: ASTM 5504
Part Number: 220-90855-14
Analytes: Sulfur Compounds
Detectors: SCD/FID
Columns: 2 capillary
1 valve
This turnkey system is designed for the determination of individual volatile sulfur-containing compounds in gaseous fuels including natural gas. It consists of a 10-port sampling valve with 2 sample
loops, an SPL-14A and 2 capillary columns that are in parallel. The
sulfur compounds are detected by a sulfur chemiluminescence
detector and an FID-14A. The detection range is 0.01 to
1000mg/m3 based upon the analysis of a 1-cm3 sample. Must
include a data processor or data station.

www.ssi.shimadzu.com

GC-2010 Light Petroleum Sulfur Analyzer


by ASTM D 5623

GC-17A Light Petroleum Sulfur Analyzer


by ASTM D 5623

GC-14A Light Petroleum Sulfur Analyzer


by ASTM D 5623

GC-2010 Natural Gas and Gaseous Fuels Sulfur


Analyzer by ASTM D 6228

Method: ASTM 5623


Part Number: 220-90876-20
Analytes: Sulfur Compounds
Detectors: SCD
Columns: 1 capillary
Valves: none
This turnkey system covers the determination of volatile sulfur-containing compounds in light petroleum liquids. The system is applicable to distillates, gasoline motor fuels (including those containing
oxygenates) and other petroleum liquids with a final boiling point
of approximately 230C. Detection of sulfur compounds is accomplished using a sulfur chemiluminescence detector. The applicable
concentration range of individual sulfur species is 0.1 to 100mg/kg.
Must include a data processor or data station.

Method: ASTM 5623


Part Number: 220-90876-17
Analytes: Sulfur Compounds
Detectors: SCD
Columns: 1 capillary
Valves: none
This turnkey system covers the determination of volatile sulfur-containing compounds in light petroleum liquids. The system is applicable to distillates, gasoline motor fuels (including those containing
oxygenates) and other petroleum liquids with a final boiling point
of approximately 230C. Detection of sulfur compounds is accomplished using a sulfur chemiluminescence detector. The applicable
concentration range of individual sulfur species is 0.1 to 100mg/kg.
Must include a data processor or data station.

Method: ASTM 5623


Part Number: 220-90876-14
Analytes: Sulfur Compounds
Detectors: SCD
Columns: 1 capillary
Valves: none
This turnkey system covers the determination of volatile sulfur-containing compounds in light petroleum liquids. The system is applicable to distillates, gasoline motor fuels (including those containing
oxygenates) and other petroleum liquids with a final boiling point
of approximately 230C. Detection of sulfur compounds is accomplished using a sulfur chemiluminescence detector. The applicable
concentration range of individual sulfur species is 0.1 to 100mg/kg.
Must include a data processor or data station.

Method: ASTM 6228


Part Number: 220-90877-20
Analytes: Sulfur Compounds
Detectors: FPD
Columns: 1 capillary
1 valve
This turnkey system provides for the determination of individual
volatile sulfur-containing compounds in gaseous fuels using the
FPD-2010 Flame Photometric Detector. The detection range for
sulfur compounds is from 0.02 to 20 mg/m3 of sulfur based upon
the analysis of a 1ml sample using a gas sampling valve. Must
include a data processor or data station.

GC-17A LPG Analyzer by GPA Standard

GC-17A Light Petroleum Sulfur Analyzer by ASTM D 5623

To order call 1-800-477-1227

www.ssi.shimadzu.com

GC-17A Natural Gas and Gaseous Fuels Sulfur


Analyzer by ASTM D 6228
Method: ASTM 6228
Part Number: 220-90877-17
Analytes: Sulfur Compounds
Detectors: FPD
Columns: 1 capillary
1 valve
This turnkey system provides for the determination of individual
volatile sulfur-containing compounds in gaseous fuels using the
FPD-17 Flame Photometric Detector. The detection range for sulfur
compounds is from 0.02 to 20 mg/m3 of sulfur based upon the
analysis of a 1ml sample using a gas sampling valve. Must include
a data processor or data station.

GC-14A Natural Gas and Gaseous Fuels Sulfur


Analyzer by ASTM D 6228
Method: ASTM 6228
Part Number: 220-90877-14
Analytes: Sulfur Compounds
Detectors: FPD
Columns: 1 capillary
1 valve
This turnkey system provides for the determination of individual
volatile sulfur-containing compounds in gaseous fuels using the

FPD-14 Flame Photometric Detector. The detection range for


sulfur compounds is from 0.02 to 20 mg/m3 of sulfur based upon
the analysis of a 1ml sample using a gas sampling valve. Must
include a data processor or data station.

GC-17A LPG Analyzer by GPA Standard


Method: GPA 2177
Part Number: 220-90861-17
Analytes: C6+, N2/air, CH4, CO2, C2, H2S, C3-C5
Detectors: TCD
Columns: 2 packed
2 valves
This turnkey system is constructed according to The Gas Processors
Association. C6+ components are grouped into a single peak using
a pre-cut column, which is backflushed to elute the hexanes and
heavier as the first peak. Nitrogen/air, methane, carbon dioxide
and ethane through n-pentane elute on forward flow of carrier gas
through the partition column. In addition, the system calculates
the liquid volume %, specific gravity, and vapor pressure. Analysis
time is approximately 18 minutes. In most cases, He and H2 are
either not present or present in such small quantities that these
need not be determined. Must include a data processor or data
station.

GC-14A LPG Analyzer

GC-17A Simulated Distillation Analyzer

Part Number: 220-90463-14


Analytes: C6+, C3-C5
Detectors: TCD
Columns: 3 packed
2 valves
The GC-14A Liquid Petroleum Gas System is a turnkey analyzer
that quantitates saturated and unsaturated C3-C5 hydrocarbons,
and C6+ backflushed as one initial peak. In addition, the system
calculates the liquid volume %, specific gravity, and vapor pressure.
Analysis time is approximately 35 minutes. In most cases, He and
H2 are either not present or present in such small quantities that
these need not be determined. Must include a data processor or
data station.

Method: ASTM 2887, 3710, 5307, 6352


Part Number: 220-90863-17
Detectors: FID
Columns: 1 capillary
Valves: none
This turnkey analyzer comes with the appropriate hardware and
software to perform any of the simulated distillation ASTM methods, which are ASTM D 2887, ASTM D3710, ASTM D 5307, ASTM
D 6352, and ASTM D 6417. Includes enhanced data station, GC
Solution Software, and Petro Software.

GC-2010 Simulated Distillation Analyzer


Method: ASTM 2887, 3710, 5307, 6352
Part Number: 220-90863-20
Detectors: FID
Columns: 1 capillary
Valves: none
This turnkey analyzer comes with the appropriate hardware and
software to perform any of the simulated distillation ASTM
methods, which are ASTM D 2887, ASTM D3710, ASTM D 5307,
ASTM D 6352, and ASTM D 6417. Includes enhanced data station,
GC Solution Software, and Petro Software.

GC-2010 PIANO Analyzer


Part Number: 220-90864-20
Detectors: FID
Columns: 1 capillary
Valves: none
The PIANO Analyzer is a single-column method that involves analyzing the naphtha sample for paraffins, olefins, naphthalenes, and
aromatics. This system comes with the appropriate hardware and
software to perform PIANO analysis. Includes enhanced data station, GC Solution Software, and Petro Software.

GC-2010 PIANO Analyzer


GC-2010 Simulated Distillation Analyzer

To order call 1-800-477-1227

www.ssi.shimadzu.com

GC-17A PIANO Analyzer

GC-17A DHA Analyzer

Part Number: 220-90864-17


Detectors: FID
Columns: 1 capillary
Valves: none
The PIANO Analyzer is a single-column method that involves analyzing the naphtha sample for paraffins, olefins, naphthalenes, and
aromatics. This system comes with the appropriate hardware and
software to perform PIANO analysis. Includes enhanced data station, GC Solution Software, and Petro Software.

Method: ASTM 5134


Part Number: 220-90866-17
Analytes: Detailed Hydrocarbon
Detectors: FID
Columns: 1 capillary
Valves: none
The Detailed Hydrocarbon Analysis System covers the determination of hydrocarbon components of petroleum naphthas by
ASTM D 5134. This system comes with the appropriate hardware
and software to perform DHA analysis. Includes enhanced data
station, GC Solution Software, and Petro Software.

GC-2010 DHA Analyzer


Method: ASTM 5134
Part Number: 220-90866-20
Analytes: Detailed Hydrocarbon
Detectors: FID
Columns: 1 capillary
Valves: none
The Detailed Hydrocarbon Analysis System covers the determination of hydrocarbon components of petroleum naphthas by ASTM
D 5134. This system comes with the appropriate hardware and software to perform DHA analysis. Includes enhanced data station, GC
Solution Software, and Petro Software.

GC-17A Oxygenates in Gasoline


by ASTM D 4815
Method: ASTM 4815
Part Number: 220-90462-17
Analytes: 15 Oxygenated Compounds
Detectors: FID
Columns: 1 packed, 1 capillary
1 valve
This turnkey system quantitates oxygenates in gasoline based on
ASTM D 4815. Individual ethers are determined from 0.1 to 20.0
as %. Individual alcohols are determined from 0.1 to 12.0 mass %.
Analysis time is approximately 15 minutes. Must include a data
processor or data station.

GC-2010 Oxygenates in Gasoline by ASTM D 4815


Method: ASTM 4815
Part Number: 220-90462-20
Analytes: 15 Oxygenated Compounds
Detectors: FID
Columns: 1 packed, 1 capillary
1 valve
This turnkey system quantitates oxygenates in gasoline based on
ASTM D 4815. Individual ethers are determined from 0.1 to 20.0
as %. Individual alcohols are determined from 0.1 to 12.0 mass %.
Analysis time is approximately 15 minutes. Must include a data
processor or data station.

GC-14A Oxygenates in Gasoline


by ASTM D 4815
Method: ASTM 4815
Part Number: 220-90462-14
Analytes: 15 Oxygenated Compounds
Detectors: FID
Columns: 1 packed, 1 capillary
1 valve
This turnkey system quantitates oxygenates in gasoline based on
ASTM D 4815. Individual ethers are determined from 0.1 to 20.0
as %. Individual alcohols are determined from 0.1 to 12.0 mass %.
Analysis time is approximately 15 minutes. Must include a data
processor or data station.

GC-2010 Refinery Gas by UOP 539


Method: UOP 539
Part Number: 220-90867-20
Analytes: H2, O2, N2, CO, CO2, C1-C4 hydrocarbons, C5
paraffins individually, and C5 olefins and C6+ hydrocarbons as
a composite
Detectors: 2 TCDs
Columns: 5 packed
4 valves
This automated analyzer determines the composite of gas samples, obtained from refining processes or natural sources. Noncondensable gases, methane through C4 hydrocarbons and C5
paraffins are reported individually, while C5 olefins and C6+ hydrocarbons are reported as a composite. H2S, if present, is not determined. Oxygen is not separated from argon. Usually argon is not
present in refinery gas. Lower limit of detection is approximately
0.05mol%. Analysis time is approximately 45 minutes. Must include
a data processor or data station.

GC-2010 DHA Analyzer


GC-2010 Oxygenates in Gasoline by ASTM D4815

10

To order call 1-800-477-1227

www.ssi.shimadzu.com

11

GC-14A ASTM D 2504 Analyzer

GC-2010 ASTM D 3606 Analyzer

GC-17A Sulfur and Fixed Gas Analyzer

Method: ASTM 2504


Part Number: 220-90869-14
Analytes: H2, O2, N2, CO in non-condensable gases in C2 and lighter
hydrocarbons
Detectors: TCD/FID/Methanizer
Columns: 2 packed
2 valves
This turnkey system is dedicated for the analysis of non-condensable gases in C2 and lighter hydrocarbon products. H2, O2, N2,
and CO are determined at the part per million volume level. Must
include a data processor or data station.

Method: ASTM 3606


Part Number: 220-90870-20
Analytes: Benzene, Toluene in Finished Gasoline
Detectors: TCD
Columns: 2 packed
1 valve
This automated analyzer is dedicated to the separation and quantitation of benzene and toluene in finished gasoline. Benzene can
be determined between the levels of 0.1 and 5 volume % and
toluene can be determined between the levels of 2 and 20 volume
%. Analysis time is approximately 10 minutes. Must include a data
processor or data station.

Part Number: 220-90871-17


Analytes: O2, N2, CO, CO2, COS, SO2
Detectors: TCD
Columns: 3 packed
2 valves
This unit separates and quantifies CO2, COS, SO2, N2, O2, and
CO. Also, Cl2 and TiCl4 can be quantified. Detection limit is at the
0.01 % range. Analysis time is approximately 30 minutes. Must
include a data processor or data station.

GC-2010 ASTM D 2505 Analyzer

GC-2010 Fast Refinery Gas


Part Number: 220-90868-20
Analytes: H2, CO, CO2, O2, N2, H2S, C1-C5, C6+
Detectors: TCD/FID
Columns: 6 packed
5 valves
This turnkey system is a dedicated analyzer for the analysis of refinery gases. These gases include H2, O2, N2, CO, CO2, H2S, C1C5, and C6+ hydrocarbons reported as a composite. This system
is configured with six packed columns, three sample loops, five
valves, and FID/TCD. Analysis time is approximately 20 minutes.
Must include a data processor or data station.

GC-2010 ASTM D 2504 Analyzer


Method: ASTM 2504
Part Number: 220-90869-20
Analytes: H2, O2, N2, CO in non-condensable gases in C2 and
lighter hydrocarbons
Detectors: TCD/FID/Methanizer
Columns: 2 packed
2 valves
This turnkey system is dedicated for the analysis of non-condensable gases in C2 and lighter hydrocarbon products. H2, O2, N2,
and CO are determined at the part per million volume level. Must
include a data processor or data station.

GC-17A ASTM D 2504 Analyzer


Method: ASTM 2504
Part Number: 220-90869-17
Analytes: H2, O2, N2, CO in non-condensable gases in C2 and
lighter hydrocarbons
Detectors: TCD/FID/Methanizer
Columns: 2 packed
2 valves
This turnkey system is dedicated for the analysis of non-condensable gases in C2 and lighter hydrocarbon products. H2, O2, N2,
and CO are determined at the part per million volume level. Must
include a data processor or data station.

12

To order call 1-800-477-1227

Method: ASTM 2505


Part Number: 220-90869-20
Analytes: CO2, CH4, ethane, acetylene and other hydrocarbons
Detectors: TCD/FID/Methanizer
Columns: 2 packed
2 valves
This turnkey system is dedicated for the analysis of other hydrocarbons and CO2 in high purity ethylene. CO2, CH4, ethane, acetylene and other hydrocarbons are determined at the 1 to 500 part
per million volume level. Must include a data processor or data station.

GC-17A ASTM D 2505 Analyzer


Method: ASTM 2505
Part Number: 220-90869-17
Analytes: CO2, CH4, ethane, acetylene and other hydrocarbons
Detectors: TCD/FID/Methanizer
Columns: 2 packed
2 valves
This turnkey system is dedicated for the analysis of other hydrocarbons and CO2 in high purity ethylene. CO2, CH4, ethane, acetylene and other hydrocarbons are determined at the 1 to 500 part
per million volume level. Must include a data processor or data station.

GC-14A ASTM D 2505 Analyzer


Method: ASTM 2505
Part Number: 220-90869-14
Analytes: CO2, CH4, ethane, acetylene and other hydrocarbons
Detectors: TCD/FID/Methanizer
Columns: 2 packed
2 valves
This turnkey system is dedicated for the analysis of other
hydrocarbons and CO2 in high purity ethylene. CO2, CH4, ethane,
acetylene and other hydrocarbons are determined at the 1 to 500
part per million volume level. Must include a data processor or data
station.

GC-17A ASTM D 3606 Analyzer


Method: ASTM 3606
Part Number: 220-90870-17
Analytes: Benzene, Toluene in Finished Gasoline
Detectors: TCD
Columns: 2 packed
1 valve
This automated analyzer is dedicated to the separation and quantitation of benzene and toluene in finished gasoline. Benzene can
be determined between the levels of 0.1 and 5 volume % and
toluene can be determined between the levels of 2 and 20 volume
%. Analysis time is approximately 10 minutes. Must include a data
processor or data station.

GC-14A ASTM D 3606 Analyzer


Method: ASTM 3606
Part Number: 220-90870-14
Analytes: Benzene, Toluene in Finished Gasoline
Detectors: TCD
Columns: 2 packed
1 valve
This automated analyzer is dedicated to the separation and quantitation of benzene and toluene in finished gasoline. Benzene can
be determined between the levels of 0.1 and 5 volume % and
toluene can be determined between the levels of 2 and 20 volume
%. Analysis time is approximately 10 minutes. Must include a data
processor or data station.

GC-14A Sulfur and Fixed Gas Analyzer


Part Number: 220-90871-14
Analytes: O2, N2, CO, CO2, COS, SO2
Detectors: TCD
Columns: 3 packed
2 valves
This unit separates and quantifies CO2, COS, SO2, N2, O2, and
CO. Also, Cl2 and TiCl4 can be quantified. Detection limit is at the
0.01 % range. Analysis time is approximately 30 minutes. Must
include a data processor or data station.

GCMS QP-2010 Aromatics


in Gasoline by ASTM D 5769
Method: ASTM 5769
Part Number: 220-90873-20
Analytes: 24 Aromatics
Detectors: MS
Columns: 1 capillary
Valves: none
This GCMS system is used to make the determination of total aromatics in finished gasoline, including reformulated gasoline (RFG)
containing oxygenated blending components. This method is used
to identify and quantitate concentration, in liquid volume percent,
for the following aromatics: benzene, 0.1 to 3%; toluene, 1 to 15%;
and total (C6-C12) aromatics, 10 to 40%. ASTM Method D-5769
specifies the calibration of 24 aromatic components using 4 internal standards. A macro program calculates the uncalibrated aromatic C10-C12 compounds and reports all concentrations of
compounds of interest in volume percent.

GC-2010 Sulfur and Fixed Gas Analyzer


Part Number: 220-90871-20
Analytes: O2, N2, CO, CO2, COS, SO2
Detectors: TCD
Columns: 3 packed
2 valves
This unit separates and quantifies CO2, COS, SO2, N2, O2, and
CO. Also, Cl2 and TiCl4 can be quantified. Detection limit is at the
0.01 % range. Analysis time is approximately 30 minutes. Must
include a data processor or data station.

www.ssi.shimadzu.com

13

GC-2010 Aromatics in
Finished Gasoline by ASTM D 4420

Specialty Gas Analyzers

Method: ASTM 4420


Part Number: 220-90930-20
Analytes: Aromatics to C8, C9+
Detectors: 2 TCDs
Columns: 2 packed
1 valve
This turnkey system utilizes two columns and two TCDs. A sample
is injected into a polar liquid phase column. The nonaromatics are
directed to TCD #2. The column is backflushed immediately before
the elution of benzene, and the aromatic portion is directed into
the nonpolar liquid phase column. The aromatic components elute
according to their boiling points and are detected on TCD #1.
Immediately after the C8 aromatics have eluted, the flow through
the nonpolar column is reversed to backflush the C9 and heavier
aromatics from the column through the detector.

Part Number: 220-90856-14


Analytes: N2O
Detectors: ECD
Columns: 7 packed
2 valves
This analyzer is used for the rapid precise analysis for gases containing nitrous oxide. The combination of a pre-column backflush
system with an ECD eliminates interference from water and fluorocarbons, and provides direct analysis for N2O in small sample
volumes of ambient air. The system is completely turnkey and automated, having been calibrated and tuned prior to shipment.
Analysis time is approximately 5 minutes. Must include a data
processor or data station.

GC-14A Nitrous Oxide Analyzer

GC-8A Nitrous Oxide Analyzer


GC-14A Aromatics in
Finished Gasoline by ASTM D 4420
GCMS QP-5000 Aromatics
in Gasoline by ASTM D 5769
Method: ASTM 5769
Part Number: 220-90873-50
Analytes: 24 Aromatics
Detectors: MS
Columns: 1 capillary
Valves: none
This GCMS system is used to make the determination of total aromatics in finished gasoline, including reformulated gasoline (RFG)
containing oxygenated blending components. This method is used
to identify and quantitate concentration, in liquid volume percent,
for the following aromatics: benzene, 0.1 to 3%; toluene, 1 to 15%;
and total (C6-C12) aromatics, 10 to 40%. ASTM Method D-5769
specifies the calibration of 24 aromatic components using 4 internal standards. A macro program calculates the uncalibrated aromatic C10-C12 compounds and reports all concentrations of
compounds of interest in volume percent.

Method: ASTM 4420


Part Number: 220-90930-14
Analytes: Aromatics to C8, C9+
Detectors: TCD
Columns: 2 packed
1 valve
This turnkey system utilizes two columns and a dual filament TCD.
A sample is injected into a polar liquid phase column. The nonaromatics are directed to the reference side of the TCD and vented to
atmosphere. The column is backflushed immediately before the
elution of benzene, and the aromatic portion is directed into the
nonpolar liquid phase column. The aromatic components elute
according to their boiling points and are detected on the analytical side of the TCD. Immediately after the C8 aromatics have eluted,
the flow through the nonpolar column is reversed to backflush the
C9 and heavier aromatics from the column through the detector.

Part Number: 220-90856-08


Analytes: N2O
Detectors: ECD
Columns: 7 packed
2 valves
This analyzer is used for the rapid precise analysis for gases containing nitrous oxide. The combination of a pre-column backflush
system with an ECD eliminates interference from water and fluorocarbons, and provides direct analysis for N2O in small sample
volumes of ambient air. The system is completely turnkey and
automated, having been calibrated and tuned prior to shipment.
Analysis time is approximately 5 minutes. Must include a data
processor or data station.

Range of concentrations determined from 0.1 to 5%. This system


is described in ASTM D 1746. Analysis time is approximately 10
minutes. Must include a data processor or data station.

GC-8A Chlorine Gas Analyzer 2


by ASTM D 1746
Method: ASTM 1746
Part Number: 220-90465-01
Analytes: H2, O2, N2, CH4, CO, CO2
Detectors: TCD
Columns: 9 packed
2 valves
This turnkey system is for the analysis of H2, O2, N2, CH4, CO, and
CO2 impurities in chlorine gas. Chlorine concentration is not determined. Components heavier than CO2 are backflushed to vent.
Range of concentrations determined from 0.1 to 5%. This system
is described in ASTM D 1746. Analysis time is approximately 10
minutes. Must include a data processor or data station.

GC-8A Chlorine Gas Analyzer 1


by ASTM D 1746
Method: ASTM 1746
Part Number: 220-90465-00
Analytes: H2, O2, N2, CH4, CO, CO2
Detectors: TCD
Columns: 9 packed
2 valves
This turnkey system is for the analysis of H2, O2, N2, CH4, CO, and
CO2 impurities in chlorine gas. Chlorine concentration is not determined. Components heavier than CO2 are backflushed to vent.

GCMS QP 2010 Aromatics in Gasoline

GC-14A N2 Nitrous Oxide Analyzer

14

To order call 1-800-477-1227

www.ssi.shimadzu.com

15

GC-17A Specialty Gas Analyzer 1

GC-17A Specialty Gas Analyzer 2

GC-17A H2 Contaminants Analyzer

Part Number: 220-90857-17


Analytes: H2, O2, N2, CH4, CO, CO2, SF6, CF4, SiF4
Detectors: PDD
Columns: 3 packed
3 valves
The use of Ultra High Purity (UHP) specialty gases demands stringent product purity specifications particularly for the semi-conductor industry. The purity level is <500ppb for CO2, CO, HF, SF6,
CF4, Sif4, N2, and O2/AR. A confidence level of 50ppb has been
determined in daily practical analyses. A GC-17A with a Valco Pulse
Discharge Detector (GC-PDD) is used to achieve the required
detection levels. All these impurities have a relatively higher vapor
pressure than the specialty gases. The pre-column delays the specialty gas and the system is tuned to backflush the matrix to waste.
This system incorporates a column switching valve that allows the
sample to be separated and analyzed by one of two columns at a
time. Analysis time is approximately 10 minutes per column selection. Must include a data processor or data station.

Part Number: 220-90858-17


Analytes: H2, O2, N2, CH4, CO, CO2, Light Hydrocarbons
Detectors: PDD
Columns: 3 packed
3 valves
The use of Ultra High Purity (UHP) specialty gases demands stringent product purity specifications particularly for the semi-conductor industry. The purity level is <500ppb for H2, O2, N2, CH4,
CO, CO2 and light hydrocarbons. A GC-17A with a Valco Pulse
Discharge Detector (GC-PDD) is used to achieve the required
detection levels. This turnkey system has a pre-column that delays
the specialty gas and the system is tuned to backflush the matrix
to waste. The system is designed to pre-cut the fixed gases.
However, H2 is allowed to pass to the detector. The analysis order
is H2, CO2, light hydrocarbons, O2, N2, CH4, and CO. Analysis
time is approximately 20 minutes. Must include a data processor
or data station.

Part Number: 220-90859-17


Analytes: Ar, N2, CH4, CO, CO2
Detectors: TCD
Columns: 3 packed
2 valves
This turnkey analyzer is dedicated to the separation and quantitation of impurities in hydrogen. This system consists of a two-stream
selection in which Ar, N2, CH4, CO, and CO2 are analyzed by a
TCD-17A. Analysis time is approximately 25 minutes. Must include
a data processor or data station.

GC-14A H2 Contaminants Analyzer


Part Number: 220-90859-14
Analytes: Ar, N2, CH4, CO, CO2
Detectors: TCD
Columns: 3 packed
2 valves
This turnkey analyzer is dedicated to the separation and quantitation of impurities in hydrogen. This system consists of a two-stream
selection in which Ar, N2, CH4, CO, and CO2 are analyzed by a
TCD-14A. Analysis time is approximately 25 minutes. Must include
a data processor or data station.

GC-8A H2 Contaminants Analyzer


Part Number: 220-90859-08
Analytes: Ar, N2, CH4, CO, CO2
Detectors: TCD
Columns: 3 packed
2 valves
This turnkey analyzer is dedicated to the separation and quantitation of impurities in hydrogen. This system consists of a two-stream
selection in which Ar, N2, CH4, CO, and CO2 are analyzed by a
TCD-8A. Analysis time is approximately 25 minutes. Must include
a data processor or data station.

GC-14A N2 Contaminants Analyzer


Part Number: 220-90860-14
Analytes: H2, O2
Detectors: TCD
Columns: 1 packed
2 valves
This turnkey analyzer is dedicated to the separation and quantitation of impurities in nitrogen. This system consists of a two-stream
selection in which H2, and O2 are analyzed by a TCD-14A. Analysis
time is approximately 7 minutes. Must include a data processor or
data station.

GC-17A N2 Contaminants Analyzer


Part Number: 220-90860-17
Analytes: H2, O2
Detectors: TCD
Columns: 1 packed
2 valves
This turnkey analyzer is dedicated to the separation and quantitation of impurities in nitrogen. This system consists of a two-stream
selection in which H2 and O2 are analyzed by a TCD-17A. Analysis
time is approximately 7 minutes. Must include a data processor or
data station.

GC-8A N2 Contaminants Analyzer


Part Number: 220-90860-08
Analytes: H2, O2
Detectors: TCD
Columns: 1 packed
2 valves
This turnkey analyzer is dedicated to the separation and quantitation of impurities in nitrogen. This system consists of a two-stream
selection in which H2, and O2 are analyzed by a TCD-8A. Analysis
time is approximately 7 minutes. Must include a data processor or
data station.

GC-17A Specialty Gas Analyzer

16

To order call 1-800-477-1227

www.ssi.shimadzu.com

17

Environmental and Safety


GC-17A TOGAS
Method: ASTM 3612
Part Number: 220-90799-00
Analytes: H2, O2, N2, CH4, CO, CO2, C2H4, C2H6, C2H2
Detectors: PDD/FID/Methanizer. Could substitute TCD for PDD
Columns: 2 Capillary
3 valves
The TOGAS GC-17A Dissolved Gas in Transformer Oil Analysis
System offers a turnkey system for the analysis of H2, O2, N2, CH4,
CO, CO2, C2H6, C2H4, and C2H2 in mineral spirit-based transformer oil via direct injection. Meets ASTM D 3612-98 requirements. Features a GC-17A with FID and PDD detectors, valves,
columns, methanizer, and patented oil stripper. System operation
is completely automated. Analysis time is approximately 5-10 minutes depending on backflush of high concentrated samples. Must
include a data processor or data station.

GC-14A TOGAS
Method: ASTM 3612
Part Number: 220-90249-14
Analytes: H2, O2, N2, CH4, CO, CO2, C2H4, C2H6, C2H2
Detectors: PDD/FID/Methanizer
Columns: 6 packed
2 valves
The TOGAS-14 Transformer Oil Gas Analysis System is completely
turnkey, having been calibrated and tuned prior to shipment. The
GC-14A TOGAS gives accurate measurement of dissolved gases
which include H2, O2, N2, CH4, CO, CO2, C2H6, C2H4, and C2H2
in mineral spirit-based transformer oil via direct injection. Meets
ASTM D 3612-98 requirements. Features a GC-14A with FID and
TCD detectors, valves, columns, methanizer, and patented oil stripper. System operation is completely automated. Analysis time is
approximately 25 minutes. Must include a data processor or data
station.

18

To order call 1-800-477-1227

GC-14A Greenhouse Gas Analyzer

GC-14A Fuel Cell Analyzer

GC-17A Methane in Exhaust Analyzer by SAE J1511

Part Number: 220-90804-00


Analytes: N2O, CH4, CO2 in air
Detectors: ECD/FID
Columns: 3 packed
3 valves
This model quantitates atmospheric trace gases, CO2, CH4, N2O,
in air matrix. This turnkey system is equipped with 2 sample loops,
one delivers the sample to an ECD for N2O and CO2 detection
and the other delivers the sample to an FID for the detection of
CH4. Generally, this system represents a useful and efficient tool
for a large number of studies on greenhouse gases. Analysis time
is approximately 5 minutes. Must include a data processor or data
station.

Part number: 220-90862-14


Analytes: H2, O2, N2, CH4, CO, CO2, Light Hydrocarbons
Detectors: TCD/FID/Methanizer
Columns: 2 packed
3 valves
This turnkey system is designed for the analysis of gases produced from a catalytic reformer during the fuel cell process.
The system provides valuable information for the design, performance and optimization of the reformer operation. The
system determines H2, O2, N2, CH4, CO, CO2 and other key
species. The system consists of a GC-14 with TCD and FID with
methanizer, along with the valves and columns required for the
application. Must include a data processor or data station.

Method: SAE J1511


Part Number: 220-90872-17
Analytes: CH4
Detectors: FID
Columns: 2 packed
1 valve
This turnkey system is constructed to the specifications of Society
of Automotive Engineers J1145. The analyzer separates methane
from the other constituents of an exhaust gas sample. The concentration of methane is determined with an FID with a detection
of approximately 1ppm. A complete cycle, from injection of one
sample to injection of a second sample, can be made in 30 seconds. Must include a data processor or data station.

GC-17A Mine Gas Analyzer

GC-2010 Methane in Exhaust Analyzer by SAE J1511

GC-14A Methane in Exhaust Analyzer by SAE J1511

Part Number: 220-90827-17


Analytes: H2, O2, N2, CH4, CO, CO2, C2H4, C2H6, C2H2
Detectors: PDD/FID/Methanizer
Columns: 2 capillary
2 valves
The GC-17A Mine Gas System offers a turnkey system for the
analysis of H2, O2, N2, CH4, CO, CO2, C2H6, C2H4, and C2H2.
This analyzer is similar to the GC-17A TOGAS. Features a GC-17A
with FID and PDD detectors, valves, columns, and methanizer.
System operation is completely automated. Analysis time is
approximately 5-10 minutes depending on backflush of molesieve
5A column. Must include a data processor or data station.

Method: SAE J1511


Part Number: 220-90872-20
Analytes: CH4
Detectors: FID
Columns: 2 packed
1 valve
This turnkey system is constructed to the specifications of Society
of Automotive Engineers J1145. The analyzer separates methane
from the other constituents of an exhaust gas sample. The concentration of methane is determined with an FID with a detection
of approximately 1ppm. A complete cycle, from injection of one
sample to injection of a second sample, can be made in 30 seconds. Must include a data processor or data station.

Method: SAE J1511


Part Number: 220-90872-14
Analytes: CH4
Detectors: FID
Columns: 2 packed
1 valve
This turnkey system is constructed to the specifications of Society
of Automotive Engineers J1145. The analyzer separates methane
from the other constituents of an exhaust gas sample. The concentration of methane is determined with an FID with a detection
of approximately 1ppm. A complete cycle, from injection of one
sample to injection of a second sample, can be made in 30 seconds. Must include a data processor or data station.

GC-14A Mine Gas Analyzer


Part Number: 220-90827-14
Analytes: H2, O2, N2, CH4, CO, CO2, C2H4, C2H6, C2H2
Detectors: TCD/FID/Methanizer
Columns: 6 packed
3 valves
The GC-14A Mine Gas System offers a turnkey system for the analysis of H2, O2, N2, CH4, CO, CO2, C2H6, C2H4, and C2H2. This
analyzer is similar to the GC-14A TOGAS. Features a GC-14A with
FID and TCD detectors, valves, columns, and methanizer. System
operation is completely automated. Analysis time is approximately
25 minutes. Must include a data processor or data station.

GC-17A with AOC20i Autoinjector and AOC20s 150 Sample Carousel

GC-14A Mud Logging, Well Gas Sampling Analyzer


Part Number: 220-90874-14
Analytes: Stream 1 Hydrocarbons- (Total baseline measurement). Stream 2 C1-C6
Detectors: 2 FIDs
Columns: 1 packed
2 valves

www.ssi.shimadzu.com

19

Ordering Information
How to Order
Phone: For convenient ordering, use our toll-free number;
1-800-477-1227, ext. 1300
Mail:

Mail your order to:


SHIMADZU
7102 Riverwood Drive
Columbia, MD 21046

Fax:

Fax your purchase order to: 410-381-1222

Online: Visit our website, http://store.shimadzu.com, for more information


or to contact your local sales office/representative.
When you order, be sure to include:
Purchase order number
Your billing address
Your shipping address
Our catalog number and the product description
Your name and telephone number

Terms
We welcome all orders of any size.
Terms of payment are net 30 days.

Returns
Returns of any products must be authorized in advance.
Please contact SHIMADZU for a return authorization number and forwarding
instructions. All claims must be made within 60 days of shipping. Report shipping
damage to carrier.
Keep containers and packaging materials until inspection has been made.

Warranty
Information presented in this catalog is correct and reliable to the best of our
knowledge and belief, but is not guaranteed to be so.
SHIMADZU shall not, under any circumstances, be held liable for any incidental,
consequential or compensatory damage arising from the use of, or in conjunction
with its products. The maximum liability which can be assumed by SHIMADZU shall
be limited to the invoice price of the product.

20

To order call 1-800-477-1227

Order today! Call 1-800-477-1227 or log-on to www.ssi.shimadzu.com for more information.

Anda mungkin juga menyukai