Anda di halaman 1dari 33

SUSHARDA BHANDUP

BILL OF QUANTITIES

SUMMARY
Sr.No.

Description
FIRE FIGHTING SYSTEM

Total Amount
Supply Installation

Total

A.

PUMP ROOM

B.

INTERNAL HYDRANT SYSTEM

C.

EXTERNAL HYDRANT SYSTEM

D.

SPRINKLER SYSTEM

PORTABLE FIRE EXTINGUISHERS

GRAND TOTAL

Fire Fighting Works

1 of 33

GOLD CREST
FIRE FIGHTING BOQ

GOLD CREST - BOQ FOR FIRE FIGHTING SYSTEM

Ite
m
Item Description
No.
1 ) FIRE FIGHTING SYSTEM

Qty. Unit

Rate (Rs.)
Installati
Supply
on

A. EQUIPMENTS AND PIPE WORK IN PUMP ROOM


A.1 Diesel Pump (Hydrant & Sprinkler )
Supply, Installation, testing and commissioning of
Diesel Engine driven (stand by) fire pumping
set as per specification.
(a)Supply, Installation, testing and commissioning of
Diesel Engine driven (stand by) fire pumping set
suitable for automatic operation consisting of the
following as per specification.capacity of 1800 LPM
against a total head of 90 meter.
(b)Water cooled, high speed Diesel Engine of suitable
B.H.P. running at 2900 RPM . speed including fuel, day
oil tank, 12 volts battery with leads, exhaust pipe etc
(C)Common base plate for mounting pump and motor
fabricated of suitable MS channel and Coupling guard
etc.
(d)Supply, Installation, testing and commissioning of
Diesel Engine driven (stand by) fire pumping set
suitable for automatic operation consisting of the
following as per specification:
(e)Suitable
RCC
pump
foundations
as
per
manufacturer's design and 6 Nos. Dunlop antivibration
(cushy foot) heavy duty mounting pads with vibration
eliminators of approved make.

Set

710,000

35,250

Set

412,000

28,250

A.2 Main Pump (Sprinkler)


Supply, Installation, testing and commissioning of
Electric motor driven fire pumping set suitable
for automatic operation consisting as per the below
specification & TEFC specification:
(a)Horizontal mounted centrifugal type single stage
fire pump having cast iron body, stainless steel shaft,
bronze impeller & capacity of 1800 LPM Pump
against a total head of 90 meter.
(b)Squirel cage induction motor totally enclosed fan
cooled type suitable for 415 Volt (+,- 10%) 3 Phase 50
Hz AC supply of suitable capacity for the above pump
with Synchronous speed of 2900 rpm confirming to
IS:325.
(C)Anti-vibration mounted pad.
(d)Suitable
RCC
pump
foundations
as
per
manufacturer's design and 6 Nos. Dunlop antivibration
(cushy foot) heavy duty mounting pads with vibration
eliminators of approved make.
A.3 Main Pump (Hydrant)
Supply, Installation, testing and commissioning of
Electric motor driven fire pumping set suitable
for automatic operation consisting as per the TEFC&
below specification:
BOQ-FF

GOLD CREST
FIRE FIGHTING BOQ

(a) Horizontal mounted centrifugal type single stage


fire pump having cast iron body, stainless steel shaft,
bronze impeller & capacity of 1800 LPM Pump
against a total head of 90 meter.
(b)Squirel cage induction motor totally enclosed fan
cooled type suitable for 415 Volt (+,- 10%) 3 Phase 50
Hz AC supply of suitable capacity for the above pump
with Synchronous speed of 2900 rpm confirming to
IS:325.
(c)Anti-vibration mounted pad.
(d)Suitable
RCC
pump
foundations
as
per
manufacturer's design and 6 Nos. Dunlop antivibration
(cushy foot) heavy duty mounting pads with vibration
eliminators of approved make.

BOQ-FF

Set

412,000

28,250

GOLD CREST
FIRE FIGHTING BOQ

A.4 Jockey Pump (Hydrant & Sprinkler )


Supply, Installation, testing and commissioning of
Cubical type floor mounted fire pumps of capacity of
180 LPM 90 mtr. Head i.e. Electric hydrant pump,
stand by diesel pump, pressurized (Jockey) pump and
terrace pump control Panel fabricated from 16 Swg MS
sheet duly painted with stove enameled finish of
approved shade as per given in specification & TEFC
specification.

Set

126,000

12,250

A.5 Booster Pump


Supply, Installation, testing and commissioning of
Electric motor driven fire (Terrace) pump of capacity
450 LPM 45 mtr. Head with 15 H.P. TEFC motor at
2900 r.p.m. complete with coupling, coupling guard,
base plate, anti vibration pad, foundation etc. as per
TEFC specification.

Set

62,250

8,250

A.6 Pump Room Piping


Supply, installation, testing and commissioning of
above ground G.I. Pipe "C" class ERW of following
sizes conforming to IS 1239 & IS 3589 (For above
150mm dia pipe) along with fittings & including MS
pipe support with one coat of red oxide primer & two
coats of post office fire red enamel paint, etc.
complete in all respect as specs.
a 200 mm dia.
b 150 mm dia.
c 100 mm dia.
d 80 mm dia.
e 65 mm dia.
f 50 mm dia.
g 32 mm dia.
h 25 mm dia
i 20 mm dia.

12
12
30
6
QRO
QRO
QRO
6
QRO

Mtr
Mtr
Mtr
Mtr
Mtr
Mtr
Mtr
Mtr
Mtr

2,860
2,150
1,890
1,430
1,120
860
430
280
230

710
650
520
380
325
280
190
160
130

A.7 Butterfly
valve
Providing and
fixing C.I lever operated wafer type
butterfly valves complete as per IS:13095 with
flange bolts, nuts, rubber gaskets, insertions etc. (PN
16) etc.
a 200 mm dia.
b 150 mm dia.
c 100 mm dia.
d 80 mm dia.
e 50 mm dia.

5
9
1
2
QRO

Nos.
Nos.
Nos.
Nos.
Nos.

16,250
14,250
10,250
8,140
4,250

650
550
450
350
150

3
1
2

No.
No.
No.

15,800
11,000
8,250

650
550
150

A.8 Providing and fixing C.I.'Y' type strainer flange


end with
bronze perforated sheet basket with
pressure rating upto PN16 including
rubber
gasket, flanges, nuts, bolts and washers, complete as
a required.
200 mm dia.
c
c

150 mm dia.
80 mm dia.

A.9 Air Cushion Tank (Air vessel) for Hydrant

BOQ-FF

GOLD CREST
FIRE FIGHTING BOQ

Providing and fixing Air cushion tank (air-vessel) 450


m dia x 2000 mm as per specification it is 10mm high
with dished top, made of minimum 6 mm thick M.S.
pipe/plate complete with 25 mm dia. Brass Air Valve
(Ball valve, pressure gauge type), 25 mm dia. Stop
with brass stop cock, nipple, tees, elbow, pipe and all
accessories as required incl. fixing brackets.

BOQ-FF

No.

32,250

4,530

GOLD CREST
FIRE FIGHTING BOQ

A.1 Pressure Gauge


Supply, installation, testing and commissioning of
Providing and fixing Pressure gauge with isolation
cock suitable with U tube for maximum pressure of 7
Kg/cm2. (0-14 Kg./cm2; dial size:100 mm dia.)

Nos.

2,850

250

1
5
2

Nos.
Nos.
Nos.

18,250
12,560
4,980

650
550
150

Set

2,290

250

A.1 Fire Panel (for Hydrant System)


Supply, installation, testing and commissioning of
cubical type, floor mounted extensible at both ends
dust & vermin proof panel working on 440 V , 3 phase
& 50 cycles AC supply compartmentalized, made of
14/16 gauge CRCA sheet steel enclosure painted as
per tank process

Set

175,250

32,250

A.1 Diesel Engine Control Panel


Supply, installation,testing of Diesel with motor duty
TP MCCB Engine control panel fabricated from 16
SWG M.S. sheet with suitable enamel 1 No. 16 A
MCCB paint

Set

68,250

4,520

A.1 Cables ( Booster)


Supply, installation, testing and commissioning of
cables laid on trays or wall. Complete in all respect .
45
a 3 Core X 4 Sq.mm Copper Cable

Mtr

210

75

A.1 Cable Termination


Making cable termination of cables by using brass
gland connecting to the terminals by using crimping
type copper lugs, etc. complete as required.
b 3 Core X 4 Sq.mm Copper Cable

Nos.

180

75

Mtr

450

100

Mtr
Mtr

600
425

125
85

A.1 Non Return Valves


Providing and fixing cast iron double flanged wafer
type Non - return valve PN 16 of approved quality
conforming to IS:5312 with C.I. Wheel, bolts, nuts,
washers, 3mm thick
insertion rubber gaskets
complete.
a 200 mm dia.
b
c

150 mm dia.
65 mm dia.

A.1 Pressure Switch


Providing and fixing Pressure switch for automation of
pump as specified IPS100

A.1 Earthing
Supply, laying, testing and commissioning of earthling
flats of size 50 X 6 mm using MS spacers and GI 30
clamps complete in all respects
A.1 Tray
Perforated Cable Trays of Pre galvanised Enamel
painted & Power coated Finished. Steel : As per IS:
2062 /1079 & Galvanising : As per IS: 2629/4759 ,all
accessories
include
45
size : 300mm
wide
45
size : 150mm wide

BOQ-FF

GOLD CREST
FIRE FIGHTING BOQ

Total : "A" (A.1 to A.18)

BOQ-FF

GOLD CREST
FIRE FIGHTING BOQ

B. EXTERNAL HYDRANT SYSTEM


B.1 Supply, installation, testing and commissioning of
External fire hydrant G.I. pipe as per IS 1239 - Heavy
duty with anticorrosive wrapping & coating as per IS
10221 with all heavy duty fittings, such as bends,
elbows, flanges, tees, unions, couplings, expander /
reducers etc. with radiographic test & holiday test &
hydraulic test, complete as per TAC / Fire brigade /
408
a 150
dia.
CFO mm
regulation
& approval as required from stage
46
b 80
mm
dia.
wise and final.

Mtr
Mtr

1,890
960

350
250

Nos

34,250

1,250

Sets

15,250

850

Sets

8,250

350

Sets

4,250

150

Set

2,250

150

B.2 Sluice Valves


M.S. Flanged Sluice valve conforming to IS 14846 with
painting & complete with all necessary matching
flanges, bolts, nuts, jointing materials etc. to be
installed in brick masonry chamber of 1.0 m 1.0 m
1.5 m (depth) clear, M.H. with C.I. Frame & cover. The
weight of the manhole cover shall be 116 kgs.
a

150 mm dia.

B.3 Stand Post


Providing and fixing external (yard) hydrant stand post
type comprising of the stand post,plain duck foot
flanged bends, sluice valve 80mm (PN 16) and single
headed gunmetal male coupling valve conforming to
IS: 5290-1985. The stand post column shall be
galvanized conforming to IS:1239 (heavy class). The
oulet shall be angled to the ground with an
instantaneous spring lock type gunmetal female
coupling of 63mm dia for connecting to the hose
pipe. (As per drawings.)
B.4 Hydrant Valves
Providing, fixing, testing and commissioning of single
headed gun metal, ISI marked oblique pattern hydrant
landing valve Type 'A' with 80mm dia flanged inlet &
63mm dia instanteous type female outlet complete
with gunmetal cap and chain, twist release type lug
and all accessories as per (IS : 5290:1983)
B.5 Hose Pipe
Providing & fixing 100% synthetic
pyroprotect/permaline flax canvas Non- percolating
FIRE hose type B, I.S.I marked 63mm dia, 2x15m long
with gunmetal male & female couplings (IS:903)
bound & riveted to hose pipes with copper rivets and
copper wire.
B.6 Hexagonal Nozzle
Supply, installation, testing and commissioning of
Branch pipe fitted detachable hexagonal nozzle.
Complete in all respect as per spec
B.8 M. S. Box / Cabinets

BOQ-FF

GOLD CREST
FIRE FIGHTING BOQ

Providing and fixing weather proof hose cabinet


fabricated from 1.6mm M.S. sheet with front glass
door
and
locking
arrangement,
suitable
to
accommodate all the necessary pipes, accessories,
fittings etc. as per drawing. The cabinet shall be
painted with one coat of primer and 2 more coats of
synthetic enamel paint of approved shade and shall
be suitably mounted on concrete bases. The sign, \"
YARD HYDRANT\" BRIGADE INLET\" etc. shall be
painted in \"CAPITAL LETTERS in white synthetic paint.
Size - 750 x 600 x 250 (For Yard Hydrant)

BOQ-FF

Sets

3,420

250

GOLD CREST
FIRE FIGHTING BOQ

B.9 Fire Brigade Connection


Supplying & installing fire brigade header of 150 mm
dia G.I 'C' class pipe 1.5m long consisting of 4 no.s 63
mm dia GM male inlet coupling for supplying water in
fire UG tank etc. complete as required with GM cap &
chain

Set

24,250

650

B.1 Siamese Connection


Supply & installing siamese connection of 150mm dia
GI heavy class pipe 1.5m long consisting of 4 no.s 63
mm dia GM male inlet coupling mounted on 150 mm
dia 2m long GI heavy class inlet pipe with spring type
150 mm dia NRV & isolating butterfly valve for
supplying water to hydrant system as required with
matching flanges, nut, bolt, washers etc. complete in
all respects including painting with two coat to primer
& two coat of synthetic enamel with P.O red colour (as
per TAC).

Set

32,560

850

B.1 Civil Works


Excavation and refilling of trenches & commissioning
as required for underground pipeline, removing extra
earth etc. complete as required for all type of soil /
murrum / disintegrated rocks / boulders which can be 250 Cum
taken out by the excavator upto 1500 mm depth
including dewatering, shoring complete including
carting away surplus material upto lead of 1000 metre
& disposal of as required

650

Total : "B" (B.1 to B.12)


C INTERNAL HYDRANT SYSTEM
C.1 Supplying, installing and testing above ground G.I
pipe of heavy class ERW of following sizes conforming
to IS: 1239 along with necessary - hot dip Galvanised
fittings and with one coat of red oxide primer and two
coats of post office fire red enamel paint, etc. ,
complete in all respect as per spec.
a
b
c

150 mm dia.
100 mm
80 mm

C.2 Butterfly valve


Providing and fixing butterfly valves, wafer end type
class PN 16 as per I.S:13095 - 1991, including
necessary nuts, bolts, gaskets etc. complete
a 150 mm dia.
b 100 mm dia.
c 80 mm dia.

BOQ-FF

128 Mtr
QRO Mtr
QRO Mtr

3
2
24

Nos.
Nos.
Nos.

1,890
1,250
960

350
250
190

14,250
8,250
6,120

750
500
380

10

GOLD CREST
FIRE FIGHTING BOQ

C.3 Hydrant Valves


Providing, fixing, testing and commissioning of single
headed gun metal, ISI marked oblique pattern hydrant
landing valve Type 'A' with 80mm dia flanged inlet &
63mm dia instanteous type female outlet complete 24
with gunmetal cap and chain, twist release type lug
and all accessories as per (IS : 5290:1983)
C.4 Hose Pipe
Providing & fixing 100% synthetic
pyroprotect/permaline flax canvas Non- percolating
FIRE hose type B, I.S.I marked 63mm diax15m long
with gunmetal male & female couplings (IS:903)
bound & riveted to hose pipes with copper rivets and
wire. Nozzle
C.5 copper
Hexagonal

24

Supplying Branch pipe fitted detachable hexagonal


24
nozzle. Complete in all respect as per spec
C.6 First Aid Hose Reel Drum
Supplying and installing testing and commissing of
wall mounting swinging hose reel drum as per IS 884
and fitted with 20mm dia x 30meter long high
pressure rubber hose pipe with GM isolation valve as
per IS 444 with GM chrome plated shut off nozzle with 24
necessary MS bracket for holding hose reel drum
fitted in position on wall with anchor fastner in
approved manner etc., complete as required inside
the hose box including 25mm GI pipe from stub to
hose reel
C.7 Orifice Plate
Supplying & erecting one No. Brass orifice plate
having 3 mm thickness outer dia is of 140 mm & inner
dia. suitable to reduce the pressure between 3.2 16
kg/cm2 to 5.5 kg/cm2 at every double outlet hydrant
valve, complete as required.
C.8 M. S. Box / Cabinets
Providing and fixing weather proof hose cabinet
fabricated from 1.6mm M.S. sheet with front glass
door
and
locking
arrangement,
suitable
to
accommodate all the necessary pipes, accessories,
fittings etc. as per drawing. The cabinet shall be
painted with one coat of primer and 2 more coats of
synthetic enamel paint of approved shade and shall
be suitably mounted on concrete bases. The sign, \"
YARD HYDRANT\" BRIGADE INLET\" etc. shall be
painted in \"CAPITAL LETTERS in white synthetic paint.
24
Size - 1000 x 1500 x 750 (For Internal Hydrant)
Providing & fixing Air Release Valve for cold water
C.9 supply risers, suitable for pressure not less than 15
Kg/Sq.cm.
25mm dia
2
C.1 Providing and fixing forged brass ball valve with
0 forged brass ball (suitable for test pressure of not less
than 15 kg / sq.cm of the following size :
a 25mm dia

BOQ-FF

Nos.

8,250

350

Nos.

4,250

150

Nos.

2,550

150

Nos.

12,340

1,150

Nos.

600

150

Set

6,200

450

Nos.

2,250

230

Nos.

1,750

150

11

GOLD CREST
FIRE FIGHTING BOQ

Total : "C" (C.1 to C.10)


SPRINKLERS
Providing & Laying "C" class G.I Pipes as per IS 1239
with screwed ends including ' all necessary heavy
quality fitting such as bends,tees,elbows,coupling
reducers, unions,checkneuts etc., joining with Teflon
D.1 tapes structural supports incluiding cutting welding
,threading as required etc., all complete. The pipes
shall be painted with 2 coats of primer & 2 coats of
finishing paints.
a 150 NB
b 100 NB
c 80 NB
d 65 NB
e 50 NB
f 40 NB
g 32 NB
h 25 NB
i 20 NB
D

BOQ-FF

210
50
120
390
460
280
560
2080
QRO

Mtr
Mtr
Mtr
Mtr
Mtr
Mtr
Mtr
Mtr
Mtr

1,800
1,250
960
750
550
425
400
350

350
250
175
140
115
85
70
60

12

GOLD CREST
FIRE FIGHTING BOQ

D.2 Butterfly Valve


Providing and fixing water type C.I. double flanged
butterfly valves complete with bolts, nuts, rubber
gaskets, insertions etc. of B 190 class (PN 16) etc.
a 150 NB
b 100 NB
c 80 NB
d 65 NB
e 50 NB
f 25 NB

QRO
4
3
41
QRO
QRO

Nos.
Nos.
Nos.
Nos.
Nos.
Nos.

D.3 Ball Valve


Providing and fixing forged brass ball valve with
forged brass ball (suitable for test pressure of not less
than 15 kg / sq.cm of the following size :
94 Nos.
d 50 NB
QRO Nos.
e 32 NB
QRO Nos.
f 25 NB
D.4 Air
Release
Valve
Providing
& fixing
Air Release Valve for cold water
supply risers, suitable for pressure not less than 15
Kg/Sq.cm.
a 25mm dia

Nos.

Providing, fixing, testing and commissioning of 15mm


D.5 dia. Quartzoid bulb type sprinkler with
temperature rating at 68/79C made out of forged
1300 Nos.
brass and in nickel chrome finish. (Pendent /upright
/conventional type)
Supply only of spare sprinklers individually packed in
48 Nos.
polythene bags
D.6 Providing, fixing, testing and commissioning of 15mm
dia. Quartzoid bulb type sprinkler with
150 Nos.
temperature rating at 68/79C made out of forged
brass and in nickel chrome finish. (Side Wall)
Supply only of spare sprinklers individually packed in
QRO Nos.
polythene bags
Supply and installation of Flow switches complete
D.7 with
i) flow switch & pressure switch
ii) isolation ball valve with tamper switch
iii) Orifice plate with flange to maintain a pressure of
2.2 ksc at the tap-off as required
iv) Drain assembly includes drain valve, test valve,
site flow indicator as shown and complete with all
necessary accessories.
24 Nos.
a 150 NB
QRO Nos.
b 100 NB
QRO Nos.
c 80 NB

8,250
6,120
4,560

500
380
250

3,120

210

2,250

230

450

250

450

250

500

250

11,630
7,750
6,200

950
750
600

72,580

10,250

D.8 Supply and installation of valve station as


specified and shown on drawings and complete with
i) Main butterfly valve
1
BOQ-FF

Nos.

13

GOLD CREST
FIRE FIGHTING BOQ

ii) Installation valve with retard chember & motor


gong
iii) Pressure gauges
iv) Test connection with isolation valve
v) All inter connected galvanized steel, piping
strainers valves in trim line, drain piping etc.,

D.9 Orifice Plate


Supplying & erecting one No. Brass orifice plate
having 3 mm thickness outer dia is of 140 mm & inner 16
dia. suitable to reduce the pressure between 3.2
kg/cm2 to 5.5 kg/cm2

Nos.

72,580

10,250

Nos.

600

150

Total : "D" (D.1 to D.8)

BOQ-FF

14

GOLD CREST
FIRE FIGHTING BOQ

PORTABLE
FIRE EXTINGUISHERS
Supply, installation,
testing and commissioning of
10kgs. capacity Dry chemical powder type fire
E.1 extinguisher ISI Marked. (Electric meter room & Lift
machine room)
E

Supply, installation, testing and commissioning 5 kgs


E.2 capacity Dry Chemical Powder type fire
extinguisher, ISI marked. Capacity each shall be
kept for 100 sq. mtrs area in the basement.

Nos.

12,580

350

24

Nos.

8,250

250

Total : "E" (E.1 to E.2)


GRAND TOTAL ( A + B + C + D + E )

BOQ-FF

15

GOLD CREST
FIRE FIGHTING BOQ

TING SYSTEM
Amount(Rs.)
Supply
Installation

Total
Amount

710,000

35,250

745,250

412,000

28,250

440,250

BOQ-FF

16

GOLD CREST
FIRE FIGHTING BOQ

412,000

BOQ-FF

28,250

440,250

17

GOLD CREST
FIRE FIGHTING BOQ

252,000

24,500

276,500

49,500

8,900

58,400

34,320
25,800
56,700
8,580

8,520
7,800
15,600
2,280

42,840
33,600
72,300
10,860

1,680

960

2,640

81,250
128,250
10,250
16,280

3,250
4,950
450
700

84,500
133,200
10,700
16,980

47,400
11,000
16,500

1,950
550
300

49,350
11,550
16,800

BOQ-FF

18

GOLD CREST
FIRE FIGHTING BOQ

64,500

BOQ-FF

9,060

73,560

19

GOLD CREST
FIRE FIGHTING BOQ

22,800

2,000

24,800

18,250
62,800
9,960

650
2,750
300

18,900
65,550
10,260

11,450

1,250

12,700

175,250

32,250

207,500

68,250

4,520

72,770

9,450

3,375

12,825

360

150

510

13,500

3,000

16,500

27,000
19,125

5,625
3,825

32,625
22,950

BOQ-FF

20

GOLD CREST
FIRE FIGHTING BOQ

2,776,205

BOQ-FF

241,215

3,017,420

21

GOLD CREST
FIRE FIGHTING BOQ

771,120
44,160

142,800
11,500

913,920
55,660

68,500

2,500

71,000

106,750

5,950

112,700

57,750

2,450

60,200

29,750

1,050

30,800

15,750

1,050

16,800

BOQ-FF

22

GOLD CREST
FIRE FIGHTING BOQ

23,940

BOQ-FF

1,750

25,690

23

GOLD CREST
FIRE FIGHTING BOQ

24,250

650

24,900

32,560

850

33,410

162,500

162,500

1,174,530

333,050

1,507,580

241,920

44,800

286,720

42,750
16,500
146,880

2,250
1,000
9,120

45,000
17,500
156,000

BOQ-FF

24

GOLD CREST
FIRE FIGHTING BOQ

198,000

8,400

206,400

102,000

3,600

105,600

61,200

3,600

64,800

296,160

27,600

323,760

9,600

2,400

12,000

148,800

10,800

159,600

4,500

460

4,960

3,500

300

3,800

BOQ-FF

25

GOLD CREST
FIRE FIGHTING BOQ

1,271,810

114,330

1,386,140

378,000
62,500
115,200
292,500
253,000
119,000
224,000
728,000

73,500
12,500
21,000
54,600
52,900
23,800
39,200
124,800

451,500
75,000
136,200
347,100
305,900
142,800
263,200
852,800

BOQ-FF

26

GOLD CREST
FIRE FIGHTING BOQ

33,000
18,360
186,960

2,000
1,140
10,250

35,000
19,500
197,210

293,280

19,740

313,020

4,500

460

4,960

585,000

325,000

910,000

21,600

12,000

33,600

75,000

37,500

112,500

279,120

22,800

301,920

72,580

10,250

82,830

BOQ-FF

27

GOLD CREST
FIRE FIGHTING BOQ

72,580

10,250

82,830

9,600

2,400

12,000

3,741,600

843,440

4,585,040

BOQ-FF

28

GOLD CREST
FIRE FIGHTING BOQ

62,900

1,750

64,650

198,000

6,000

204,000

260,900

7,750

268,650

9,225,045

1,539,785

10,764,830

BOQ-FF

29

TAKE-OFF SHEET (Fire Fighting)


Description

Sr.No.
A
1
a
b
c
d
e
f
g
2
2.1
a
b
c
d
2.2
a
b
2.3
a
b
c

250 mm dia (For delivery Header (2))


150 mm dia (At Delivery head of Pump(8)
100 mm dia (Test Connection Pipe (3)
80 mm dia (At Suction & Delivary Head of Jockey Pumps (6))

e
f

No.
No.
No.
No.

2.00
8.00
3.00
6.00

No.

11.00

No.

17.00

No.

2.00

Ball valve
40 mm dia (Air Vessal tank to Delivery Header Line (5)& Priming
to Pump inlet(6))
25 mm dia (at pressure switches to Air Vessel tank line)

Non Return Valve


250 mm dia (Delivary Header (2))
150 mm dia (At delivary Head of the pumps & Drencher Pump (2
for H.L. & L.L.)
80 mm dia (At delivery Head of jockey pumps)

No.
No.

8.00
4.00

Air Release valve

150 mm dia (At Delivery Head of pumps)


80 mm dia (At Delivery Head of jockey pumps)

1.00
1.00
1.00
1.00
1.00
1.00
1.00

Valves
Butterfly Valves

2.5
b
c

No.
No.
No.
No.
No.
No.
No.

Pumps
Diesel Pump - 1800 LPM
Main Electric Pump (Hydrant) - 1800 LPM
Main Electric Pump (Sprinkler) - 1800 LPM
Jockey Pump(Hydrant) - 180 LPM
Jockey Pump(Sprinkler) - 180 LPM
Booster Pumps at terrace - 450 LPM
Drencher Pump - 2400 LPM

25mm dia (At delivery Header (2))

4
a
b

Qty.

Pump room

2.4
a

Unit

No.

2.00

No.
No.

4.00
2.00

No.

12.00

C.I. strainer with foot valve

Pressure Switch

Piping (Pump Room)


250 mm dia. (Suction Header From Tank to Pump Mtr.
Room)
150 mm dia. (Suction Header to pump & Delivery Mtr.
Header)
100 mm dia. (Test connection & Muncipal Water
Mtr.
supply line)

30
65
30

80 mm dia. (Suction Header to Pump Inlet & Outlet


Mtr.
Jockey Pump)

30

50 mm dia.( At Pressure Switch Station)


Mtr.
40 mm dia.( At Air Vessel to delivery Header &
Mtr.
Priming tank to pump inlet)

15
50

25 mm dia. (Pressure Switch Station to Air Vessel Mtr.


Line)
Air Cushion tank (Air Vessel)
No.

5.00

Pressure Gauge (Pump Room & Booster Pump (2)) No.

15.00

7
a
b
c
d
e
B
1
a
b
c
d
2
2.1
2.2
a
b

10

Panels
Fire control Panel
Diesel Engine Control panel
Cables
Cable Termination
Cable tray

No.
No.
No.
No.
No.

1.00
1.00
1.00
1.00
1.00

Hydrant system

Piping
Mtr. 150.00
150 mm dia.(External Hyadrant loop for Low Level)
150 mm dia (Riser qty) (as per 18/11/2009 NOC Pt.15.C)
(High Level 130 + Low level from pump room to 22nd floor Mtr. 220.00
90)
100 mm dia (Riser from 17th to terrace Booster Pump)
(as
Mtr. 40.00
per IS 3844)
Mtr. 40.00
100 mm dia (Each floor Hydrant Pipe length 1.3m (G+28))
Valves
Butterfly Valve (At bottom of riser in shaft)
Air release Valve

No.

2.00

40 mm dia (For External hydrant loop at GF)


25 mm dia (At the top of Riser (For Low & High Level Pipe))

No.
No.

1.00
2.00

3
4
5
6
7
8
9
10
11

Stand Post (HYDRANT) (At Ground Floor)


Hydrant Valves
M. S. Box / Cabinets
Hose Pipe
Hexagonal Nozzle
First Aid Hose Reel Drum
Orifice Plate
Fire Brigade Connection
Siamese Connection (For Low & High Level Loop)

No.
No.
No.
No.
No.
No.
No.
No.
No.

4.00
4.00
4.00
8.00
8.00
8.00
8.00
1.00
2.00

C
1

Sprinkler system

Piping

150 mm dia (Riser High Level 130 & Low level 90)
(as per 18/11/2009 NOC Pt.15.C)

Mtr. 210.00

b
c
d
e
f

65 mm dia (40 mtr for G+6 internal)


50 mm dia (10 mtr for G+6 internal)
40 mm dia (10 mtr for G+6 internal & 20mtr for 7 to 28 Floor)
32 mm dia (20 mtr for G+6 internal & 10mtr for 7 to 28 Floor)
25 mm dia (20 mtr for G+6 internal & 15mtr for 7 to 28 Floor)

Mtr.
Mtr.
Mtr.
Mtr.
Mtr.

Valves

280.00
70.00

###
###
###

Butterfly Valves

2.1
a
b

150 mm dia. (At bottom of riser in shaft)


65 mm dia (For G+6 Floor)

2.2
a

40 mm dia (For 7 to 28 Floor)

No.
No.

2.00
7.00

No.

22.00

No.
No.

7.00
22.00

No.

2.00

No.
No.

29.00
1.00

No.
No.

7.00
22.00

Pendent (For G+6= 22/floor & 7 to 28=5/floor) & extra 10%

No.

289.00

Portable Fire Extinguisher


Fire buckets (round bottom) with initially filled with dry clean sand
including stand.
9 lit capacity each (In Electric Room & Lift M/C Room)

No.

2.00

Dry chemical powder (A.B.C.) type fire extinguisher having I.S.I.


Certification mark
10 kg capacity (2 on each floor & Electric, Lift M/C Room)

No.

60.00

Ball valve

Control Valve

2.3
a
b

65 mm dia (For G+6 Floor)


40 mm dia (For 7 to 28 Floor)

2.4
a

25 mm dia (For Low & High Level Risers)

2.5
a
b

25 mm dia (For G+28 Floors & At bottom of Riser)


80 mm dia (At bottom of Riser)

2.6
a
b

65 mm dia (For G+6 Floor)


40 mm dia (For 7 to 28 Floor)

3
a

D
1

G
G.1

Air release Valve

Brass Drain Valve

Flow Switch / Pressure switch

Sprinkler

Drencher Distribution ( external side of Building )

a
b
c
d
e
f
g
h

Piping
150 mm dia (Riser)
100 mm dia (From shaft to 7th sprinkler)
80 mm dia (7th to 27th sprinkler)
65 mm dia (28th to 37th sprinkler)
50 mm dia (38th to 42nd sprinkler)
40 mm dia (43rd & 44th floor)
32 mm dia (45th sprinkler)
25 mm dia (46th & 47th sprinkler)

Mtr.
Mtr.
Mtr.
Mtr.
Mtr.
Mtr.
Mtr.
Mtr.

90.00
35.00
65.00
35.00
20.00
10.00
5.00
10.00

G.2
a

Butterfly Valves
100 mm dia (From shaft to Sprinkler line)

No.

1.00

G.3

Deluge Valve

No.

1.00

G.4
a

Air release Valve


25 mm dia (For Riser)

No.

1.00

G.5

Drencher Nozzle

No.

47.00

No.
Mtr.
No.
No.
No.
No.

2.00
50.00
4.00
2.00
2.00
2.00

H
a
b
c
d
e
f

Booster Pump
Booster Pump
Terrece Loop Piping
Butterfly Valve (150 mm dia.)
Pressure Guage
Non Return Valve
Stainer

Anda mungkin juga menyukai