Accessories
Applications
In the shown example pictures, surface blemishes were found on wall and
kicker areas. Ultrasonic testing was carried out to ensure continued
integrity of the concrete. Areas of the concrete that were not required to
be investigated were introduced into the survey for comparison purposes.
It was established that the consistency of the concrete placed was uniform
and indicated no presence of voids.
Ultrasonic pulse velocity testing Epoxy applications
Application examples
Wood testing
Technical Data
Range
Resolution
Display
Pulse Voltage UPV
Pulse Voltage UPE
Bandwidth
Receiver Gain
Pundit PL-200PE
0.1 7930 s
0.1 s (< 793 s), 1 s (> 793 s)
7 colour display 800x480 pixels
100 450 Vpp
100 400 Vpp
20 500 kHz
1x 10000x (0 80dB) [11 steps]
Memory
Regional Settings
Battery
Battery Lifetime
Operating
Temperature
Humidity
IP Classification
Features
Compressive strength
Crack location
Homogeneity / Uni-formity
Slab thickness
Accessories
Applications
dengan
Note:
Ultrasonic pulse echo testing Ground floors
The Pundit PL-200PE dapat digunakan sebagai instrumen kontrol kualitas dalam
industri konstruksi. Hal ini digunakan untuk memeriksa ketebalan lantai tanah,
apakah ketebalan minimum dicapai, dan berapa banyak ketebalan bervariasi.
Cara merusak pengeboran inti digunakan di masa lalu, atau hari ini sebagai
referensi pengukuran tunggal.
Contoh Aplikasi
Bercak void potensial dan retak beton in-situ di antara dinding prefabrikasi
pengujian Kayu
Menggunakan
tensioning
Menemukan void selama dan setelah instalasi dinding rongga manikmanik isolasi
echo
pulsa
ultrasonik
untuk
mencari
kabel
Technical Data
Range
Resolution
Display
Pulse Voltage UPV
Pulse Voltage UPE
Bandwidth
Receiver Gain
Memory
Regional Settings
Pundit PL-200PE
0.1 7930 s
0.1 s (< 793 s), 1 s (> 793 s)
7 colour display 800x480 pixels
100 450 Vpp
100 400 Vpp
20 500 kHz
1x 10000x (0 80dB) [11 steps]
Internal 8 GB Flash memory
Metric and imperial units and multi-language
posting
Battery
Battery Lifetime
Operating
Temperature
Humidity
IP Classification
supported
Lithium Polymer, 3.6 V, 14.0 Ah
> 8h (in standard operating mode)
0C 30C (Charging, running instrument)
0C 40C (Charging, instrument is off)
-10C 50C (Non-charging)
< 95 % RH, non condensing
IP54