Application
These valves are designed to meet the needs of HVAC and commercial
applications requiring bubble tight shut-off for liquids. Typical applications
include chiller isolation, cooling tower isolation, change-over systems, large
air handler coil control, bypass and process control applications. The large
Cv values provide for an economical control valve solution for larger flow
applications.
Jobsite Note
Valves should be stored in a weather protected area prior to construction.
DN
[mm]
2-way
115
36
50
F650VIC
260
80
65
F665VIC
440
140
80
F680VIC
820
250
100
F6100VIC
1200
370
125
F6125VIC
1800
560
150
F6150VIC
3400
1050
200
F6200VIC
5800
1800
10
250
F6250VIC
9000
2790
12
300
F6300VIC
Valve
F650VIC
F665VIC
F680VIC
F6100VIC
F6125VIC
F6150VIC
F6200VIC
F6250VIC
F6300VIC
Size
2
2-1/2
3
4
5
6
8
10
12
Cv
115
260
440
820
1200
1800
3400
5800
9000
800-543-9038 USA
16
30
7
16
26
50
70
110
200
350
540
40
14
30
50
100
140
220
410
700
1080
50
23
50
90
160
240
360
670
1150
1780
60
36
80
140
250
370
560
1050
1800
2790
866-805-7089 CANADA
70
60
140
230
430
620
940
1770
3020
4680
90
115
260
440
820
1200
1800
3400
5800
9000
IN
Electronic
Fail-Safe
GK Series
Cv
60
Non-Spring
Return
SY Series
Cv
90
Spring
Return
GM Series
Type
AF Series
Technical Data
Service
Flow characteristic
Controllable flow range
Sizes
Type of end fitting
Valve materials*
Body
Body finish
Disc
Seat
Shaft
Bearing
Body pressure rating
Media temperature range
Rangeability
Maximum close-off pressure
Maximum velocity
Valve
Nominal Size
Suitable Actuators
AM
2-way
C (Max)
8.60
8.60
8.60
8.60
8.00
8.00
8.00
8.00
8.00
8.00
8.00
8.00
2.40
2.40
2.40
9.20
9.20
9.20
9.20
10.90
10.90
10.90
Actuator
AF
Close-Off (PSI)
200
50
200
50
200
50
200
200
50
200
50
200
200
200
50
200
200
50/200
50/200
200
50/200
200
2*AF
GK
2*GK
AM...
GM...
2*GM
SY1...
SY2...
SY2/ SY3
SY4
SY4/ SY5
SY6
Dimensions
3.858
[97.99]
6.393
[162.38]
8.553
[217.25]
1.852
[47.05]
Application Notes
1. Valves are rated at 200 psi differential pressure in the closed position
2. 2-way assemblies are furnished assembled and tested, ready for installation.
3. Dimension D allows for actuator removal without the need to remove the
valve from the pipe.
4. Belimo SY Series actuators are NEMA 4X rated.
5. Provide support for the actuator if it is mounted at any angle other than 90
vertical.
6. Installer is to use rigid type couplings for connecting the valve to the piping.
10
4
[101.6]
m
m
mm
/11
.9
/88
2
1/
/60
.3
/7
3
.0
mm
&
76
.1
4.
3
5
m
/1
41 m &
.3
10
m
8.
6
m
0
/1
,1
m
68
m
33
.3
.0
m
m
m
m
&1
&
8
65
13
/21
.1
9.
9.1
m
7
m
m
mm
m
&
10
15
/2
9.
0
73
m
.0
m
mm
12
/3
23
.9
mm
0.1
D
D(Max)
14.00
14.50
18.70
18.70
14.65
14.95
20.25
13.20
13.60
14.00
14.30
19.60
15.70
16.20
16.40
26.00
26.70
27.70
28.20
33.30
35.00
36.00
Non-Spring Return
B (Max)
2.00
2.00
8.60
8.60
7.00
7.00
8.60
4.70
4.70
7.00
7.00
8.60
3.20
3.20
3.20
4.60
4.60
4.60
4.60
7.30
7.30
7.30
Electronic
Fail-Safe
A(Max)
3.21
3.77
3.77
3.77
3.21
3.77
3.77
3.21
3.77
3.77
3.77
4.63
3.21
3.77
3.77
3.77
4.63
5.88
5.88
5.33
6.40
6.50
Spring
Return
0.01
10
100
1000
10000
C
A
800-543-9038 USA
866-805-7089 CANADA
17
Application
These valves are designed to meet the needs of HVAC and commercial
applications requiring bubble tight shut-off for liquids. Typical applications
include chiller isolation, cooling tower isolation, change-over systems, large
air handler coil control, bypass and process control applications. The large
Cv values provide for an economical control valve solution for larger flow
applications.
Jobsite Note
Valves should be stored in a weather protected area prior to construction.
Cv
60
IN
DN
[mm]
2-way
115
36
50
F750VIC
260
80
65
F765VIC
440
140
80
F780VIC
820
250
100
F7100VIC
1200
370
125
F7125VIC
1800
560
150
F7150VIC
3400
1050
200
F7200VIC
5800 1800
10
250
F7250VIC
9000
12
300
F7300VIC
2790
Non-Spring
Return
Electronic
Fail-Safe
Valve
F750VIC
F765VIC
F780VIC
F7100VIC
F7125VIC
F7150VIC
F7200VIC
F7250VIC
F7300VIC
Size
2
2
3
4
5
6
8
10
12
Cv
115
260
440
820
1200
1800
3400
5800
9000
800-543-9038 USA
18
30
7
16
26
50
70
110
200
350
540
40
14
30
50
100
140
220
410
700
1080
50
23
50
90
160
240
360
670
1150
1780
60
36
80
140
250
370
560
1050
1800
2790
866-805-7089 CANADA
70
60
140
230
430
620
940
1770
3020
4680
90
115
260
440
820
1200
1800
3400
5800
9000
Cv
90
Spring
Return
GK Series
Type
SY Series
Valve
Nominal Size
GM Series
AF
Series
Technical Data
Service
Flow characteristic
Controllable flow range
Sizes
Type of end fitting
Valve materials*
Body
Body finish
Disc
Seat
Shaft
Bearing
Body pressure rating
Media temperature range
Rangeability
Maximum close-off pressure
Maximum velocity
Suitable Actuators
AM
3-way
B (Max)
2.00
2.00
8.60
6.50
7.50
8.00
6.50
6.50
7.50
7.50
8.00
6.50
7.50
7.50
8.00
9.60
11.40
12.40
12.40
13.10
15.40
15.40
16.50
D(Max)
14.00
14.00
18.70
15.25
14.65
20.25
13.20
13.60
14.00
14.30
19.60
15.70
16.20
16.40
26.00
26.70
27.70
28.20
33.30
35.00
35.10
38.70
39.70
Actuator
AF
Close-Off (PSI)
50
200
50
200
50
50
50
200
50
200
50
200
50
200
200
200
200
50
200
200
50
200
200
2*AF
GK
2*GK
AM...
GM...
2*GM
SY1...
SY2...
SY3...
SY4...
SY6...
SY7...
Dimensions
7.559
[192]
4.551
[115.6]
3.627
[92.12]
Application Notes
1. Valves are rated at 200 psi differential pressure in the closed position
2. 2-way assemblies are furnished assembled and tested, ready for installation.
3. Dimension D allows for actuator removal without the need to remove the
valve from the pipe.
4. Belimo SY Series actuators are NEMA 4X rated.
5. Provide support for the actuator if it is mounted at any angle other than 90
vertical.
6. Installer is to use rigid type couplings for connecting the valve to the piping.
C
B
8.406
[213.51]
3.858
[97.99]
10
m
41 m &
.3
10
m
8.
m
0
/1
,1
m
68
m
3
.3
3.
0
m
m
m
m
&1
&
8
65
13
/21
.1
9.
9.1
m
7
m
m
mm
m
&
10
15
/2
9.
0
73
m
.0
m
mm
12
/3
23
.9
mm
3.627
[92.12]
C
A
5
/1
/11
4
10
100
1000
10000
0.1
0.01
4.
3
mm
.9
2
1/
2
3
/88
.3
/7
3.
mm
&
76
.1
2
/60
C (Max)
8.60
8.60
8.60
13.60
14.10
14.30
13.10
13.60
14.10
14.10
14.30
15.70
16.20
25.70
26.00
26.70
27.70
28.30
32.10
33.30
35.10
38.70
39.70
Non-Spring Return
A(Max)
3.21
3.21
3.77
3.21
3.77
3.77
3.20
3.20
3.80
3.80
3.80
3.20
3.80
3.80
3.80
4.60
5.90
5.90
5.90
5.30
6.40
6.40
6.50
Spring Electronic
Return Fail-Safe
800-543-9038 USA
866-805-7089 CANADA
19
Technical Data
Electrical connection
conduit connector,
screw terminals
Motor protection
Gear train
Operating range
Sensitivity
Reversal hysteresis
(SY24MFT)1.0 mA/500mV
Feedback
Angle of rotation
90
Direction of rotation
reversible
Position indication
Auxiliary switches
Ambient temperature
Humidity range
up to 95%
Housing type
IP67, NEMA 4X
Housing material
Agency listings
Power Supply
Torque
Speed
Power
Consumption
On/Off
MFT
Override
Weight
35Nm/310 in-lbs
15s
1.8A
30%
75%
8mm Wrench
2.0kg/4.9 lb.
SY2-24(MFT)
90Nm/801 in-lbs
15s
3.0A
30%
75%
Hand Wheel
11kg/24.5 lb.
SY3-24(MFT)
150Nm/1335 in-lbs
22s
3.0A
30%
75%
Hand Wheel
11kg/24.5 lb.
SY4-24(MFT)
400Nm/3560 in-lbs
16s
6.0A
30%
75%
Hand Wheel
22kg/48.5 lb.
SY5-24(MFT)
500Nm/4450 in-lbs
22s
6.5A
30%
75%
Hand Wheel
22kg/48.5 lb.
Model
SY1-24(P)
800-543-9038 USA
866-805-7089 CANADA
43
Electrical connection
Motor protection
Gear train
Operating range
Sensitivity
Reversal hysteresis
Feedback
Angle of rotation
90
Direction of rotation
reversible
Position indication
Auxiliary switches
Ambient temperature
Humidity range
up to 95%
Housing type
IP67, NEMA 4X
Housing material
Agency listings
Torque
Speed
60Hz
Speed
50Hz
Power
Consumption
On/Off
Proportional
Override
Weight
35Nm/310 in-lbs
12s
13s
0.5A
30%
75%
8mm Wrench
2.0kg/4.9 lb.
SY2-120(MFT)
90Nm/801 in-lbs
15s
17s
1.0A
30%
75%
Hand Wheel
11kg/24.5 lb.
SY3-120(MFT)
150Nm/1335 in-lbs
22s
26s
1.0A
30%
75%
Hand Wheel
11kg/24.5 lb.
SY4-120(MFT)
400Nm/3560 in-lbs
16s
18s
1.3A
30%
75%
Hand Wheel
22kg/48.5 lb.
SY5-120(MFT)
500Nm/4450 in-lbs
22s
25s
1.5A
30%
75%
Hand Wheel
22kg/48.5 lb.
SY6-120(MFT)
650Nm/5785 in-lbs
28s
31s
1.8A
30%
75%
Hand Wheel
22kg/48.5 lb.
SY7-120(MFT)
1000Nm/8900 in-lbs
46s
55s
3.2A
30%
75%
Hand Wheel
36kg/79.5 lb.
SY8-120(MFT)
1500Nm/13350 in-lbs
46s
55s
4.0A
30%
75%
Hand Wheel
36kg/79.5 lb.
Model
SY1-110(P)
SY9-120(MFT)
2000Nm/17800 in-lbs
58s
70s
3.2A
30%
50%
Hand Wheel
56kg/123.5 lb.
SY10-120(MFT)
2500Nm/22250 in-lbs
58s
70s
4.0A
30%
50%
Hand Wheel
56kg/123.5 lb.
SY11-120(MFT)
3000Nm/26700 in-lbs
58s
70s
3.0A
30%
50%
Hand Wheel
56kg/123.5 lb.
SY12-120(MFT)
3500Nm/31150 in-lbs
58s
70s
4.0A
30%
50%
Hand Wheel
56kg/123.5 lb.
800-543-9038 USA
44
866-805-7089 CANADA
Technical Data
Technical Data
Electrical connection
conduit connector,
screw terminals
Overload protection
Motor protection
Gear train
Operating range
Sensitivity
Reversal hysteresis
Feedback
Angle of rotation
90
Direction of rotation
reversible
Position indication
Auxiliary switches
Ambient temperature
Humidity range
up to 95%
Housing type
IP67, NEMA 4X
Housing material
Agency listings
Power Supply
Torque
Speed
60Hz
Speed
50Hz
Power
Consumption
On/Off
MFT
Override
Weight
35Nm/310 in-lbs
12s
13s
0.3A
30%
75%
8mm Wrench
2.0kg/4.9 lb.
SY2-230(MFT)
90Nm/801 in-lbs
15s
17s
0.5A
30%
75%
Hand Wheel
11kg/24.5 lb.
SY3-230(MFT)
150Nm/1335 in-lbs
22s
26s
0.5A
30%
75%
Hand Wheel
11kg/24.5 lb.
SY4-230(MFT)
400Nm/3560 in-lbs
16s
18s
0.6A
30%
75%
Hand Wheel
22kg/48.5 lb.
SY5-230(MFT)
500Nm/4450 in-lbs
22s
25s
0.7A
30%
75%
Hand Wheel
22kg/48.5 lb.
SY6-230(MFT)
650Nm/5785 in-lbs
28s
31s
0.8A
30%
75%
Hand Wheel
22kg/48.5 lb.
Model
SY1-220(P)
SY7-230(MFT)
1000Nm/8900 in-lbs
46s
55s
1.6A
30%
75%
Hand Wheel
36kg/79.5 lb.
SY8-230(MFT)
1500Nm/13350 in-lbs
46s
55s
2.0A
30%
75%
Hand Wheel
36kg/79.5 lb.
SY9-230(MFT)
2000Nm/17800 in-lbs
58s
70s
1.6A
30%
50%
Hand Wheel
56kg/123.5 lb.
SY10-230(MFT)
2500Nm/22250 in-lbs
58s
70s
2.0A
30%
50%
Hand Wheel
56kg/123.5 lb.
SY11-230(MFT)
3000Nm/26700 in-lbs
58s
70s
1.6A
30%
50%
Hand Wheel
56kg/123.5 lb.
SY12-230(MFT)
3500Nm/31150 in-lbs
58s
70s
2.2A
30%
50%
Hand Wheel
56kg/123.5 lb.
800-543-9038 USA
866-805-7089 CANADA
45
D
B
SY-1...
SY-2~6...
B
SY-9~12...
SY-7~8...
B
MODEL
DIM A (MAX)
DIM B
DIM C (MAX)
DIM D
Inches [mm]
Inches [mm]
Inches [mm]
Inches [mm]
Inches [mm]
SY1
6.10 [155]
3.94 [100]
4.25 [108]
8mm
SY2~3
10.04 [255]
7.48 [190]
7.87 [200]
12.99 [330]
7.87 [200]
SY4~6
12.40 [315]
8.86 [225]
9.21 [234]
14.96 [380]
11.81 [300]
SY7~8
16.54 [420]
8.86 [225]
9.21 [234]
17.72 [450]
13.39 [340]
SY9~12
23.23 [590]
8.86 [225]
10.24 [260]
18.50 [470]
13.78 [350]
800-543-9038 USA
46
866-805-7089 CANADA
BF2WUDIM_A
Models
AFBUP-X1
AFBUP-S-X1
AFXUP-X1
AFXUP-S-X1
Technical Data
Power supply
Power consumption
Transformer sizing
Electrical connection
AFBUP...
AFXUP...
Overload protection
Control
Torque
Direction of rotation
Mechanical angle of rotation
Running time
Position indication
Manual override
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency listings
Noise level
Servicing
Quality standard
Weight
Valve
F650HD
F650HDU
F665HD
F665HDU
F680HD
F680HDU
F6100HDU
F6125HDU
F650-150SHP
F665-150SHP
F680-150SHP
F6100-150SHP
F650-300SHP
F665-300SHP
F680-300SHP
F6100-300SHP
F650VIC
F665VIC
F665VIC
F680VIC
Size
2
2
2
2
3
3
4
5
2
2
3
4
2
2
3
4
2
2
2
3
A
1.65
1.65
1.76
1.76
1.78
1.78
2.05
2.14
1.75
1.88
1.92
2.13
1.75
1.88
1.92
2.13
3.21
3.77
3.77
3.77
Dimensions (Inches)
B
C D(Max)
9.00 9.00 19.50
9.00 9.00 19.50
9.00 9.00 20.00
9.00 9.00 20.00
9.00 9.00 20.50
9.00 9.00 20.50
9.00 9.00 21.00
9.00 9.00 22.00
9.00 9.00 19.50
9.00 9.00 20.00
9.00 9.00 20.50
9.00 9.00 21.00
9.00 9.00 19.50
9.00 9.00 20.00
9.00 9.00 20.50
9.00 9.00 21.00
9.00 9.00 18.50
9.00 9.00 19.75
9.00 9.00 20.50
9.00 9.00 20.50
BHC
4.75
4.75
5.50
5.50
6.00
6.00
7.50
8.50
4.75
5.50
6.00
7.50
5.00
5.88
6.63
7.88
-
Rated Impulse Voltage 4kV, Type of action 1.AA (1.AA.B for -S version), Control Pollution Degree 3.
AFBUP-S-X1, AFXUP-S-X1
Auxiliary switches
800-543-9038 USA
62
866-805-7089 CANADA
BHC
B
Provide overload protection and disconnect as required.
Size
2
2
2
2
3
2
2
2
A
4.50
4.50
5.00
5.00
5.50
4.50
4.50
5.00
Dimensions (Inches)
B
C
D(Max)
6.15
6.15
15.50
6.15
6.15
15.50
6.76
6.76
16.00
6.76
6.76
16.00
7.28
7.28
16.25
6.85
6.85
15.00
6.85
6.85
15.00
7.46
7.46
15.50
10
Valve
F750HD
F750HDU
F765HD
F765HDU
F780HDU
F750VIC
F750VIC
F765VIC
10
BHC
4.75
4.75
5.50
5.50
6.00
-
WARNING
G Live Electrical Components!
During installation, testing, servicing and troubleshooting of this product, it may be
necessary to work with live electrical components. Have a qualified licensed electrician or other
individual who has been properly trained in handling live electrical components perform these
tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury.
W066_AFB(X)UP
Typical Specification
On/Off spring return damper actuators shall be direct coupled type which require
no crank arm and linkage and be capable of direct mounting to a jackshaft up to a
1.05 diameter. The actuators must be designed so that they may be used for either
clockwise or counterclockwise fail-safe operation. Actuators shall be protected
from overload at all angles of rotation. If required, two SPDT auxiliary switch shall
be provided having the capability of one being adjustable. Actuators with auxiliary
switches must be constructed to meet the requirements for Double Insulation so
an electrical ground is not required to meet agency listings. Actuators shall be
cULus approved and have a 5 year warranty, and be manufactured under ISO 9001
International Quality Control Standards. Actuators shall be as manufactured by Belimo.
AFBUP, AFBUP-S
AFXUP, AFBUP-S
W067_AFB(X)UP-S
Wht
Blk
AFBUP-S
AFXUP-S
800-543-9038 USA
866-805-7089 CANADA
63
BF2WUDIM
BF2WUDIM_A
Models
AFX24-MFT-X1
AFX24-MFT-S-X1 w/built-in Aux. Switches
2*AFX24-MFT-X1
2*AFX24-MFT-S-X1
Technical Data
Power supply
Rated Impulse Voltage 800V, Type of action 1.AA (1.AA.B for -S version), Control Pollution Degree 3.
Programmed for 70 sec motor run time. At 150 sec motor run time, transformer sizing
iis 8.5 VA and power consumption is 6 W running / 3 W holding.
AFX24-MFT-S-X1
Auxiliary switches
800-543-9038 USA
64
Size
2
2
2
2
3
3
4
5
2
2
3
4
2
2
3
4
2
2
3
Dimensions (Inches)
B
C D(Max)
9.00 9.00 19.50
9.00 9.00 19.50
9.00 9.00 20.00
9.00 9.00 20.00
9.00 9.00 20.50
9.00 9.00 20.50
9.00 9.00 21.00
9.00 9.00 22.00
9.00 9.00 19.50
9.00 9.00 20.00
9.00 9.00 20.50
9.00 9.00 21.00
9.00 9.00 19.50
9.00 9.00 20.00
9.00 9.00 20.50
9.00 9.00 21.00
8.60 8.60 18.25
8.60 8.60 18.70
8.60 8.60 18.70
A
1.65
1.65
1.76
1.76
1.78
1.78
2.05
2.14
1.75
1.88
1.92
2.13
1.75
1.88
1.92
2.13
3.21
3.77
3.77
BHC
4.75
4.75
5.50
5.50
6.00
6.00
7.50
8.50
4.75
5.50
6.00
7.50
5.00
5.88
6.63
7.88
-
HS DWGP11
Valve
Size
F750HD
2
F750HDU 2
F765HD
2
F765HDU 2
F780HDU 3
F750VIC
2
F750VIC
2
F765VIC 2
866-805-7089 CANADA
A
4.50
4.50
5.00
5.00
5.50
4.50
4.50
5.00
Dimensions (Inches)
B
C
D(Max)
6.15
6.15
15.50
6.15
6.15
15.50
6.76
6.76
16.00
6.76
6.76
16.00
7.28
7.28
16.25
6.85
6.85
15.00
6.85
6.85
15.00
7.46
7.46
15.00
BHC
4.75
4.75
5.50
5.50
6.00
-
Valve
F650HD
F650HDU
F665HD
F665HDU
F680HD
F680HDU
F6100HDU
F6125HDU
F650-150SHP
F665-150SHP
F680-150SHP
F6100-150SHP
F650-300SHP
F665-300SHP
F680-300SHP
F6100-300SHP
F650VIC
F665VIC
F680VIC
10
BHC
10
Wiring Diagrams
6
7
W399_Butterfly
VDC/4-20 mA
The ZG-R01 500 resistor converts the 4 to 20 mA control signal to
2 to 10 VDC, up to 2 actuators may be connected in parallel.
Meets cULus or UL and CSA requirements without the
need of an electrical ground connection.
24 VAC Transformer
W399_Butterfly
Master
PWM
M
Master_Slave
Line
Volts
On/Off
Off controll
W399_Butterfly
CCW CW
Slave
Org (5) U
W600_AFB_AFX
()
Control Signal
(+)
2 to 10 VDC
CCW CW
Master/Slave
AFB24-MFT-S
AFX24-MFT-S-X11
AFX24-MFT-S
866-805-7089 CANADA
65
AM_GM_LineRevised
D
B
BHC
Models
Valve
F680HD
F6100HDU
F6125HDU
F650-150SHP
F665-150SHP
F680-150SHP
F6100-150SHP
F650-300SHP
F665-300SHP
F680-300SHP
F6100-300SHP
F6100VIC
GKRB24-3-X1
GKRB24-3-5
GKB24-3-X1
Power consumption
Transformer sizing
Electrical connection
Overload protection
Operation range Y
Input impedance
Feedback output U
Angle of rotation
Position indication
Manual override
Running time
normal operation
fail-safe
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency list
Noise level
Servicing
Quality standard
reversible with
switch
adjustable with dial or tool 0 to 100% in 10%
increments
reflective visual indicator (snap-on)
external push button
800-543-9038 USA
74
C D(Max) BHC
7.00 16.53 6.00
8.00 17.53 7.50
8.00 18.03 8.50
9.00 20.03 4.75
9.00 20.53 5.50
9.00 21.03 6.00
9.00 21.53 7.50
9.00 20.03 5.00
9.00 20.53 5.88
9.00 21.03 6.63
9.00 21.53 7.88
8.63 16.00
-
Fail-safe position
B
7.00
8.00
8.00
9.00
9.00
9.00
9.00
9.00
9.00
9.00
9.00
8.63
10
Direction of rotation
12W (3W)
21VA (class 2 power source)
18 GA plenum rated cable
" conduit connector
protected NEMA 2 (IP54)
3 ft [1m] 10 ft [3m] 16 ft [5m]
electronic throughout 0 to 95 rotation
on/off, floating point
100k (0.1 mA), 500
1500 (floating point, on/off)
2 to 10VDC, 0.5mA max, VDC variable
max. 95, adjustable with mechanical stop
electronically variable
A
1.78
2.05
2.14
1.75
1.88
1.92
2.13
1.75
1.88
1.92
2.13
4.63
Single_Buttery
Technical Data
Power supply
Size
3
4
5
2
2
3
4
2
2
3
4
4
Dimensions (Inches)
Valve
F765HD
F780HDU
F750-150SHP
F765-150SHP
F780-150SHP
F7100-150SHP
F765VIC
F780VIC
F7100VIC
866-805-7089 CANADA
Size
2
3
2
2
3
4
2
3
4
A
5.00
5.50
4.50
5.00
5.50
6.50
3.77
3.77
4.63
B
6.70
7.20
6.25
6.88
7.42
8.63
6.88
7.42
8.63
C D(Max) BHC
6.70 16.53 5.50
7.20 16.78 6.00
6.25 17.03 4.75
6.88 17.53 5.50
7.42 18.03 6.00
8.63 18.53 7.50
6.88 15.00
7.42 15.00
8.63 16.00
-
Non-Fail
Safe (psi)
GK
200
50
150
150
150
150
50
200
50
Non-Fail
Safe (psi)
GK
200
50
50
285
285
285
150
150
150
150
150
200
Dimensions (Inches)
Wiring Diagrams
T
Wiring diagram
Note
!
Connect via safety isolation transformer.
Parallel connection of other actuators possible.
Note performance data for supply.
DC 0 ... 10 V
Y
U
1
DC 2 ... 10 V
4
Cable lengths
C
Y
8
L2
Ltot
Note
When several actuators are connected in parallel,
the maximum cable length must be divided by the
number of actuators.
L1
1
A
N
WARNING
G Live Electrical Components!
AC
C 230 V
C
T
AC 24 V
L1
Cable colors:
1 = black
2 = red
3 = white
5 = orange
Actuator
Control unit
Belimo connecting cable, 1 m (4 x 0.75 mm2)
Customer cable
Maximum cable length
=
=
=
=
=
A
Cross section
L2
/
0.75 mm2
1.00 mm2
1.50 mm2
2.50 mm2
T
A
C
L1
L2
Ltot
Example for DC
W399_10
Note
There are no special restrictions on installation if
the supply and data cable are routed separately.
1 m (L 1) + 4 m (L 2)
1 m (L 1) + 7 m (L 2)
1 m (L 1) + 11 m (L 2)
1 m (L 1) + 19 m (L 2)
A = Actuator
C = Control unit
L1 = Belimo connecting cable, 1 m (4 x 0.75 mm
m2)
W399_10
On/Off
Off controll
800-543-9038 USA
866-805-7089 CANADA
75
AM_GM_LineRevised
D
B
BHC
Power consumption
Transformer sizing
Electrical connection
Overload protection
Operation range Y
Input impedance
Feedback output U
Angle of rotation
Direction of rotation
76
C D(Max) BHC
9.00 21.03 6.00
9.00 21.53 7.50
9.00 22.53 8.50
9.00 22.56 9.50
9.00 20.03 4.75
9.00 20.53 5.50
9.00 21.03 6.00
9.00 21.53 7.50
9.00 20.03 5.00
F665-300SHP
F680-300SHP
2
3
1.88
1.92
9.00
9.00
9.00
9.00
20.53
21.03
5.88
6.63
285
285
F6100-300SHP
F6100VIC
4
4
2.13
4.63
9.00
8.63
9.00
8.63
21.53
16.00
7.88
-
150
200
800-543-9038 USA
B
9.00
9.00
9.00
9.00
9.00
9.00
9.00
9.00
9.00
reversible with
switch
adjustable with dial or tool 0 to 100% in 10%
increments
reflective visual indicator (snap-on)
external push button
A
1.69
1.92
2.08
2.19
1.75
1.88
1.92
2.13
1.75
Position indication
Manual override
Running time
normal operation
fail-safe
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency list
Size
3
4
5
6
2
2
3
4
2
10
Fail-safe position
GKX24-MFT-X1
24VAC 20% 50/60Hz
24VDC 10%
12W (3W)
21VA (class 2 power source)
18 GA plenum rated cable
" conduit connector
protected NEMA 2 (IP54)
3 ft [1m] 10 ft [3m] 16 ft [5m]
electronic throughout 0 to 95 rotation
2 to 10 VDC, 4 to 20mA (default)
variable (VDC,PWM, floating point, on/off)
100k (0.1 mA), 500
1500 (PWM, floating point, on/off)
2 to 10VDC, 0.5mA max, VDC variable
max. 95, adjustable with mechanical stop
electronically variable
Valve
F680HD
F6100HDU
F6125HDU
F6150HDU
F650-150SHP
F665-150SHP
F680-150SHP
F6100-150SHP
F650-300SHP
Single_Buttery
Technical Data
Power supply
Noise level
Servicing
Quality standard
Non-Fail
Safe (psi))
GK
200
50
50
50
285
285
285
150
285
Dimensions (Inches)
GKRX24-MFT-X1
GKRB24-3-5
GKX24-MFT-X1
Dimensions (Inches)
Valve
F780HDU
F7100HDU
F7125HDU
F7150HDU
F750-150SHP
F765-150SHP
F780-150SHP
Size
3
4
5
6
2
2
A
5.50
2.05
2.14
2.19
4.50
5.00
B
7.20
8.00
8.00
8.00
6.25
6.88
C D(Max) BHC
7.20 16.78 6.00
8.00 17.00 7.50
8.00 17.50 8.50
8.00 22.50 9.50
6.25 17.03 4.75
6.88 17.53 5.50
Non-Fail Safe
(psi)
GK
2*GK
200
50
50
50
150
150
5.50
7.42
7.42
18.03
6.00
150
F765VIC
3.77
6.88
6.88
15.00
50
F780VIC
3.77
7.42
7.42
15.00
200
F7100VIC
4.63
8.63
8.63
16.00
50
866-805-7089 CANADA
Models
4
5
8
9
VDC/4-20 mA
W399_Butterfly
W399_Butterfly
Wiring Diagrams
WARNING
G Live Electrical Components!
PWM
M
W399_Butterfly
W399_Butterfly
On/Off
Off controll
800-543-9038 USA
866-805-7089 CANADA
77
AR_LineRevised
D
B
BHC
Non-Fail Safe
(psi)
HD
HDU
200
50
200
50
50
200
50
Dimensions (Inches)
Valve
Size
F650HD(U) 2
F665HD(U) 2
F680HDU
3
F650VIC
2
F665VIC
2
Technical Data
Power supply
Power consumption
Transformer sizing
Electrical connection
D(Max)
15.00
15.50
16.00
14.50
14.50
BHC
4.75
5.50
6.00
-
Noise level
Quality standard
C
7.00
7.00
7.00
7.00
7.00
10
Overload protection
Control
Input impedance
Angle of rotation
Direction of rotation
Position indication
Manual override
Running time
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency listings
B
7.00
7.00
7.00
7.00
7.00
Dimensions (Inches)
Valve
F750HD
F765HDU
F750VIC
Size
2
2
2
A
4.50
5.00
3.21
B
6.15
6.76
6.00
C
6.15
6.76
6.00
D(Max)
15.50
16.00
15.00
BHC
4.75
5.50
-
Non-Fail Safe
(psi)
HD
HDU
200
200
50
50
800-543-9038 USA
78
866-805-7089 CANADA
AMB24-3-X1
ARB24-3-X1
ARB24-3-5
A
1.65
1.76
1.78
3.21
3.77
Single_Buttery
Models
j y
Wiring Diagrams
24 VAC Transformer
Line
Volts
Red (2) +
a
a open
a closed
Wht (3) +
1 0
AMB24-3-X1
On/Off control
24 VAC Transformer
W557_10
W557_10
Line
Volts
Red (2)
Wht (3)
1 0
AMB24-3-X1
800-543-9038 USA
866-805-7089 CANADA
79
AR_LineRevised
D
B
BHC
Models
AMX24-MFT-X1
ARX24-MFT-X1
ARB24-MFT-5
A
1.65
1.76
1.78
3.21
3.77
Dimensions (Inches)
B
C
D(Max)
3.35
7.00
14.50
3.46
7.00
15.00
3.48
7.00
15.50
7.00
7.00
14.50
7.00
7.00
14.50
BHC
4.75
5.50
6.00
-
Non-Spring
Return (psi)
Valve
Size
F650HD(U) 2
F665HD(U) 2
F680HDU
3
F650VIC
2
F665VIC
2
Technical Data
Power supply
10
Dimensions (Inches)
Valve
F750HD
F765HDU
F750VIC
Size
2
2
2
A
4.50
5.00
3.21
B
6.15
6.76
6.00
C
6.15
6.76
6.00
D(Max)
15.50
16.00
15.00
BHC
4.75
5.50
-
Non-Fail Safe
(psi)
HD
HDU
200
200
50
50
800-543-9038 USA
80
866-805-7089 CANADA
Single_Buttery
24 VAC/DC Transformer
4
6
8
9
3
Blk (1) Common
Line
Volts
()
Position
Two Position
3
24 VAC Transformer
Line
Volts
A
8
B
Pnk (4) Y2 Input
2 to 10 VDC
Feedback Signal
10
W558_Butterfly
W558_Butterfly
Wiring Diagrams
11
Direction of rotation switch
CCW
CCW
CW
CW
B 5
B 5
24 VAC Transformer
Line
Volts
W558_Butterfly
Floating Point
Control Signal
4 to 20 mA
or
2 to 10 VDC
500
1/4 watt
()
(+)
Line
Volts
Position
8
()
W558_Butterfly
VDC/4-20 mA
PWM
800-543-9038 USA
866-805-7089 CANADA
81
AM_GM_LineRevised
D
B
BHC
Models
GMB24-3-X1
GRB24-3-X1
GRB24-3-5
GRB24-3-7
Technical Data
Power supply
Power consumption
Transformer sizing
Electrical connection
Overload protection
Control signal
Input impedance
Angle of rotation
Direction of rotation
Position indication
Running time
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency listings
Noise level
Servicing
Quality standard
Valve
Size
F680HD
3
F6100HD
4
F6100HDU
4
F6125HDU
5
F6150HDU
6
F650-150SHP
2
F665-150SHP 2
F680-150SHP
3
F6100-150SHP 4
A
1.78
2.05
2.05
2.14
2.19
1.75
1.88
1.92
2.13
B
7.00
8.00
8.00
8.00
8.00
9.00
9.00
9.00
9.00
C D(Max) BHC
7.00 16.00 6.00
8.00 17.00 7.50
8.00 17.00 7.50
8.00 17.50 8.50
8.00 22.50 9.50
9.00 19.50 4.75
9.00 20.00 5.50
9.00 20.50 6.00
9.00 21.00 7.50
Non-Fail Safe
(psi)
GM 2*GM
200
200
50
50
50
285
285
285
150
285
F650-300SHP
1.75
9.00
9.00
19.50
5.00
285
400
F665-300SHP
F680-300SHP
2
3
1.88
1.92
9.00
9.00
9.00
9.00
20.00
20.50
5.88
6.63
285
285
400
400
F6100-300SHP 4
F665VIC
2
F680VIC
3
F6100VIC
4
2.13
3.77
3.77
4.63
9.00
7.00
7.00
8.00
9.00
7.00
8.00
8.00
21.00
15.50
15.50
16.00
7.88
-
150
200
200
285
200
800-543-9038 USA
82
866-805-7089 CANADA
Dimensions (Inches)
Wiring Diagrams
10
Dimensions (Inches)
Non-Fail Safe
(psi)
GM 2*GM
200
200
50
50
50
50
150
285
150
285
Valve
F765HD
F780HD
F780HDU
F7100HDU
F7125HDU
F7150HDU
F750-150SHP
F765-150SHP
Size
2
3
3
4
5
6
2
2
A
5.00
5.50
5.50
6.50
7.50
8.00
4.50
5.00
B
C D(Max) BHC
6.70 6.70 16.00 5.50
7.20 7.20 16.25 6.00
7.20 7.20 16.25 6.00
8.45 8.45 17.00 7.50
9.60 9.60 17.50 8.50
10.08 10.08 18.00 9.50
6.25 6.25 16.50 4.75
6.88 6.88 17.00 5.50
F780-150SHP
5.50
7.42
7.42
17.50
6.00
150
F7100-150SHP
F750-300SHP
4
2
6.50
5.00
8.63
6.75
8.63
6.75
18.00
15.50
7.50
5.00
150
5.50
6.00
7.00
5.00
5.25
6.00
7.38
7.92
9.13
6.70
7.25
7.25
7.38
7.92
9.13
6.70
7.25
7.25
16.00
16.25
18.00
15.50
15.50
16.00
5.88
6.63
7.88
-
F765-300SHP 2
3
F780-300SHP
F7100-300SHP 4
2
F750VIC
F765VIC
2
F780VIC
3
10
Actuators with plenum rated cable do not have numbers on wires; use
color codes instead. Actuators with appliance cables are numbered.
24 VAC Transformer
285
285
285
150
Line
Volts
285
Red (2) +
a
a open
a closed
Wht (3) +
1 0
50
200
50
GMB24-3-X1
On/Off
j y
24 VAC Transformer
W559
Line
Volts
Blk (1)
Common
Red (2)
Wht (3)
W559
1 0
GMB24-3-X1
Floating Point
800-543-9038 USA
866-805-7089 CANADA
83
AM_GM_LineRevised
D
B
BHC
Non-Fail Safe
(psi)
GM 2*GM
200
200
50
50
50
285
285
285
150
285
285
400
285
400
285
400
150
285
200
200
200
Dimensions (Inches)
Technical Data
Power supply
Power consumption
Transformer sizing
Electrical connection
Overload protection
Control signal
84
800-543-9038 USA
Noise level
Servicing
Quality standard
C D(Max) BHC
9.00 20.50 6.00
9.00 21.00 7.50
9.00 21.00 7.50
9.00 22.00 8.50
9.00 22.50 9.50
9.00 19.50 4.75
9.00 20.00 5.50
9.00 20.50 6.00
9.00 21.00 7.50
9.00 19.50 5.00
9.00 20.00 5.88
9.00 20.50 6.63
9.00 21.00 7.88
7.00 15.50
8.00 15.50
8.00 16.00
-
10
Angle of rotation
Direction of rotation
Position indication
Running time
Humidity
Ambient temperature
Storage temperature
Housing
Housing material
Agency listings
B
9.00
9.00
9.00
9.00
9.00
9.00
9.00
9.00
9.00
9.00
9.00
9.00
9.00
7.00
7.00
8.00
10
Input impedance
A
1.69
1.92
1.92
2.08
2.08
1.75
1.88
1.92
2.13
1.75
1.88
1.92
2.13
3.77
3.77
4.63
Dimensions (Inches)
Valve
F765HD
F780HD
F780HDU
F7100HD
F7100HDU
F7125HDU
F7150HDU
F750-150SHP
F765-150SHP
F780-150SHP
F750-300SHP
F765-300SHP
F780-300SHP
F7100-300SHP
F750VIC
F765VIC
F780VIC
866-805-7089 CANADA
Size
2
3
3
4
4
5
6
2
2
3
2
2
3
4
2
2
3
A
5.00
5.50
5.50
6.50
6.50
7.50
8.00
4.50
5.00
5.50
5.00
5.50
6.00
7.00
5.00
5.25
6.00
B
C D(Max) BHC
6.70 6.70 16.00 5.50
7.20 7.20 16.25 6.00
7.20 7.20 16.25 6.00
8.45 8.45 17.00 7.50
8.45 8.45 17.00 7.50
9.60 9.60 17.50 8.50
10.08 10.08 18.00 9.50
6.25 6.25 16.50 4.75
6.88 6.88 17.00 5.50
7.42 7.42 17.50 6.00
6.75 6.75 15.50 5.00
7.38 7.38 16.00 5.88
7.92 7.92 16.25 6.63
9.13 9.13 18.00 7.88
6.70 6.70 15.50
7.25 7.25 15.50
7.25 7.25 16.00
-
Non-Fail Safe
(psi)
GM 2*GM
200
200
50
200
50
50
50
150
285
150
285
150
285
285
285
285
150
50
200
50
GMX24-MFT-X1
GRX24-MFT-X1
GRB24-MFT-5
GRB24-MFT-7
Size
3
4
4
5
6
2
2
3
4
2
2
3
4
2
3
4
D101
Models
Valve
F680HD
F6100HD
F6100HDU
F6125HDU
F6150HDU
F650-150SHP
F665-150SHP
F680-150SHP
F6100-150SHP
F650-300SHP
F665-300SHP
F680-300SHP
F6100-300SHP
F665VIC
F680VIC
F6100VIC
24 VAC Transformer
3
5
8
10
Actuators with plenum rated cable do not have numbers on wires; use
color coded instead. Actuators with appliance rated cable use numbers.
Control signal may be pulsed from either the Hot (Source) or
Common (Sink) 24 VAC line.
For triac sink the Common connection from the actuator must be
connected to the Hot connection of the controller.
Line
Volts
W545_No_2
Wiring Diagrams
Control Signal
4 to 20 mA
or
2 to 10 VDC
500
1/4 watt
()
(+)
Line
Volts
()
Position
Two Position
3
24 VAC Transformer
Line
Volts
Master
11
CCW
CCW
CW
()
Control Signal
(+)
2 to 10 VDC
CW
B 5
B 5
Floating Point
CCW CW
Line
Volts
Slave
10
2 to 10 VDC
Feedback Signal
Line
Volts
Master_Slave
24 VAC Transformer
W545_No_2
11
Position
()
W545_No_2
24 VAC/DC Transformer
W545_No_2
VDC/4-20 mA
Meets cULus or UL and CSA requirements without the
need of an electrical ground connection.
Contact closures A & B also can be triacs. A & B should
both be closed for triac source and open for triac sink.
Position feedback cannot be used with a Triac sink controller. The
actuator internal common reference is not compatible.
PWM
Org (5) U
CCW CW
Master/Slave
800-543-9038 USA
866-805-7089 CANADA
85