User Manual
Ver 1.0
Date Issued: 2015-07-01
Table of contents
1. Product details --------------------------------------------------------------------------------3
2. Safety Directions --------------------------------------------------------------------------4
3. Wiring Connection ---------------------------------------------------------------------------5
4. How S180 works for you?-------------------------------------------------------------------6
5. SMS Command-------------------------------------------------------------------------------7
5.1 Common operate commands--------------------------------------------------------------------------------------7
5.2 6LUHQDQGFDPHUDVPRWLRQdetector------------------------------------------------------------------------------7
5.3 $ODUP UHFHLYHUV 3KRQH QXPEHU--------------------------------------------------------------------------------7
5.4 Edit DIN1~DIN8 zone name-----------------------------------------------------------------------------------7
5.5 ',1a',1 VHQVRUV W\SH-----------------------------------------------------------------------------------------8
5.6 GPRS MMS parameters--------------------------------------------------------------------------------------------8
5.7 Email address----------------------------------------------------------------------------------------------------------8
5.8 Camera parameters--------------------------------------------------------------------------------------------------8
5.9 Other Settings-------------------------------------------------------------------------------------------------------9
6. Warranty --------------------------------------------------------------------------------9
This handbook has been designed as a guide to the installation and operation of S180 Alarm Panel.
Statements contained in the handbook are general guidelines only and in no way are designed to supersede the
instructions contained with other products.
We recommend that the advice of a registered electrician be sought before any Installation work commences.
The manufacturer, its employees and distributors, accept no liability for any loss or damage including
consequential damage due to reliance on any material contained in this handbook.
The manufacturer, its employees and distributors, accept no liability for GSM Network upgrading or SIM Card
upgrading due to the technology specifications contained in this handbook.
Features:
z
Applications:
z
Warehouse, Factory, Office, Business, Summer house, ATM station security and surveillance alarm system.
Unman Station, Reservoir, Tower, Pump, Motor, Water Supply, BTS, Remote Area monitoring and surveillance alarm
system.
Quad-band 850/900/1800/1900MHz
External outdoor water-proof
8 NC/NO dry contact
1 Relay, 3A/240VAC
12VDC/1A
DC Power supply
9~24VDC/2A
Back up battery
7.4V/1000mAH
Power consumption
SIM Card
Antenna
^D
Temperature range
Humidity range
-20~+60 C
Relative humidity 90%
Optional Accessories:
9
9
9
9
9
9
2.Safety Directions
Safe Startup
Do not use S180 when using GSM equipment is prohibited or might bring disturbance or danger.
Interference
All wireless equipment might interfere network signals of S180 and influence its performance.
LED INDICATORS
Arm
Relay
Camera
II
II
Flash : Armed
Always Light ON: Disarm.
ON: Relay closed(ON)
OFF: Relay open (OFF)
ON: Camera disconnected or wrong connection.
OFF: Camera on correct status.
Flash quickly: registering to cellular network.
Flash slowly: alarm or GPRS data communication.
OFF: registered to cellular network success.
Camera
TxD
RxD
Data Receiving
5V
Vdd (Black)
6V
GND
Arm
Siren
Relay
Power In
(Yellow)
Shielded wire
A+
Connect one NC/NO button or switch on A+ and GND port, press the button to
enter to Arm status, repress the button to Disarm.
S+
sW
S--
NO
COM
Common port
GND
DIN1~DIN8
ANT
Start
Wiring connect the camera and other digital sensors (if have) to the main unit.
If you had programmed your phone number on S180, it will send a status SMS to your phone once switch ON.
The DIN8 zone especially for entrance purpose, the sensor on DIN8 zone triggered will delay 15 seconds alarm,
so you have 15 seconds to Disarm the system before alarming.
You can also use APP of send SMS command to Arm/Disarm the system.
Alarm
When alarm raised, S180 sends alert SMS and MMS picture to your phone and make siren sound, you can
pick up the phone call to listen the onsite voice.
z/E^D^^
t
Remote Control
You can use APP or send SMS commands to switch ON/OFF the relay remotely.
Inquiry Photos
You can use APP or send SMS commands to ask S180 sending back 1~20 photos to your mobile phone.
Power Monitoring
You will receive alert SMS when AC/DC power lost and recovery, when back up battery low power, S180
makes alarm beeps for reminding.
S180 can setting by smart phone APP or SMS commands with password protection remotely.
The SMS commands should with Password, 1234 is the default password on below context, please change it
to new password if you had changed already.
S180 will not return any message if the SMS command error.
No space on the SMS commands, the space on command list just for reading purpose.
SMS Command
Function
Feedback SMS
Inquiry status
1234#01#
Disarm
1234#02#
Arm
1234#03#
1234#04#
Switch Relay ON
1234#05#
1234#06#
Switch Siren ON
Status: Armed/Disarmed
Relay: Off/On
Siren: Off/On
^
1234#10#
Inquiry settings
1234#11#
1234#12#
1234#16#
1234#15#
Siren: ON/OFF
Motion Alarm: On/Off
/
1234#21#*#
Add the 1
1234#22#*#
Add the 2
1234#23#*#
Add the 3
1234#24#*#
Add the 4
1234#25#*#
Add the 5
st
TEL1:*******
nd
TEL2:*******
rd
th
th
TEL3:*******
TEL4:*******
TEL5:*******
DIN1:*****
*=1~8
DIN2:*****
DIN3:*****
1234#30#*#
1234#31#*#
DIN4:*****
1234#33#*#
DIN5:*****
1234#34#*#
DIN6:*****
1234#35#*#
DIN7:*****
1234#36#*#
DIN8:*****
1234#37#*#
1234#38#*#
DIN1~8 ^Type
1234#7*#0#
NO
1234#7*#1#
NC
*=1~8.
NC=Normally Close, NO=Normally Open.
Default type: NC.
Format:
1234#41#*#
APN:******
1234#42#*#
User:*******
1234#43#*#
Pass:******
1234#44#*#
IP:******
1234#45#*#
Port:****
1234#46#*#
MMSC Url:******
Notice: please call your mobile operator to ask the GPRS Access Point Name, User name, Password, MMSC IP, MMSC
Port and MMSC URL. If there have no User name or Password, etc needed for the GPRS connection, then leave it)
For example:
1234#41#everywhere#
1234#42#eesecure#
1234#43#secure#
the example APN name(everywhere), User name(eescure) Password(secure) supported by Orange UK.
E-mail address
1234#50##
1234#51#email address#
Email:********
st
1234#51##
1234#52#email address#
1234#52##
Email 1:****
st
nd
nd
Email 2:****
Inquiry settings
^
*=0~2
1234#61#*#
0 =160X128;
1 = 320X240
1234#62#*#
2 = 640X480 (default)
Image Size:640*480
Image Qty:1
*=0~20
CamSensitivity:15
Default=1
sensitivity
*=1~99
1234#63#*#
1 = the highest sensitive.
Default= 15
Other Settings
Inquiry the last photos
Require Image Ok
1234#90#*#
*=1~20
Change password
1234#99#*#
*= 4 digits
PASS: 1234
1234#CN#
Language: English
1234#EN#
6. Warranty
1) This system is warranted to be free of defects in material and workmanship for one year.
2) This warranty does not extend to any defect, malfunction or failure caused by abuse or misuse by the Operating
Instructions. In no event shall the manufacturer be liable for any alarm system altered by purchasers.
www.GsmAlarmSystem.com