Alarms & Solutions

ALARM 1: Synchronization (RBS)


ALARM 2: Device_AntennaSystemProblem
ALARM 3: Loss of Cell Delineation
ALARM 4: Carrier_RXDiversityLost
ALARM 5: Device_AntennaSystemProblem or TmaDevice_AntennaSystemProblem
ALARM 6: Carrier_RejectSignalFromHardware
ALARM 7: RuDeviceGroup_GeneralHWError
ALARM 8: Device_ExternalUnitFailure
ALARM 9: ExternalTma_LnaFailureBranchA
ALARM 10: Nbap (in RNC) OR Equipment for RUDeviceGroup (in RBS)
ALARM 11: Carrier_UL_GainProblem
ALARM 12: Carrier_UL_GainTruncated
ALARM 13: AuxPlugInUnit_PiuConnectionLost
ALARM 14: Tma_LnaFailure
ALARM 15: CLU_LossofMain
ALARM 16: FCU_DeviceGroup_NumberofHWEntitiesMismatch
ALARM 17: FCU_DeviceGroup_FanFailure
ALARM 18: RXDiversityLoss
ALARM 19: CarrierReject
ALARM 20: IMAGroupInsufficientLinks
ALARM 21: PSUDeviceGroup_GeneralSWError
ALARM 22: Carrier_SingalNotReceivedWithinTime
ALARM 23: Bfu_BatteryChargingFailure
ALARM 24: UtranCell_NbapMessageFailure (in RNC)
ALARM 25: UtranCell_NbapMessagefailure (RNC)
ALARM 26: RBS_LocalCellnotAdded (RNC) or NBapMessageFailure (RNC)
ALARM 27: UtranCell_InternalResourceUnavailable or
UtranCell_NbapMessageFailure

Go to Top

Page 1

ALARM 28: Antenna alarms pointing to one sector


ALARM 29: ExternalTMA_degraded/Failed
ALARM 30: Carrier Diversity Failed/Degraded
ALARM 31: IMA UNUSABLE
ALARM 32: Carrier_ULGainTruncated
ALARM 33: Loss of Tracking & Loss of Synch Reference Redundancy
ALARM 34: Switch Core Fault or PsDevice_LossOfMains
ALARM 35: Exceeded Maximum limit
ALARM 36: Node Status Analyzer doesnt open
ALARM 37: RfCable_Disconnected equipment_malfunction
ALARM 38: loss_of_signal
ALARM 39: TU Synch Reference Loss of Signal loss_of_signal
ALARM 40:
AuxPlugInUnit_NewAuxiliaryUnitDetectedNotCorrespondingToTheDefinedConfigurati
on

ALARM 1: Synchronization (RBS)


Mostly synchronization alarms are one of the following
Loss of Tracking
TU Synch Reference Loss of Signal
PDH Loss of Signal or PDH Loss of Frame or only Loss of Signal or Loss of
Frame
In most cases, the node lost one of the synchronization references and the
node needs to be resynched.
TU Synch Reference Loss of Signal: TUB or CBU doesnt get the signal
check the input port, cables, boards themselves
Loss of Tracking: Node is not in locked mode but in holdover mode
"resetLossOfTracking" on Sync MO (use LDN of pp1 and pp2 which are the sync
references

Go to Top

Page 2

PDH Loss of Signal/Frame or Loss of Signal/Frame: ET doesnt detect the


signal
check port, cables, board (put cable between Tx and Rx on the ET), if
everything is ok, then remove this port from the sync reference

ALARM 2: Device_AntennaSystemProblem
Use the following RBS command:
Moshell <rbs>
lt antennabranch
get antennabranch antennaSupervisionThreshold
lt tma
get tma power
In the RBS there is feature to measure the VSWR (Voltage Standing Wave
Ratio). In simple words, the VSWR is a measure of the reflection in the RF
path caused by faulty equipment between the RBS and the Antenna. In case of
non-TMA sites, the RBS has another feature call DC resistance. See the
following table to see which features are used for the US market.

Table: Valid for FU12 19 and FU12 08, - = not supported


Configuration/Supervision
Feeder Power Supply SV
DC Antenna SV
VSWR Antenna SV
TMA SV
A
B
A
B
1. Only antenna
No
No
Yes
Yes
No
2. RET/RIU, no ASC/TMA
Yes, branch A
No
Yes
Yes
No
3.TMA, external power supply
No

Go to Top

Page 3

No
No
Yes
No
4. TMA, power supply by FU/AIU
Yes
No
No
Yes
Yes
5. ASC
Yes
No
No
No
No

Note: Observe that when TMA is defined Branch B has NO supervision.


If the antennasupervisionthreshold is not set correctly (general value is 49)
then we see this alarm. The formula for the different types of supervision is
in MOP and given below as well:
The threshold value 0 means that the supervision is turned off.
In this case ask the ASP to put dummy loads on the RBS to eliminate alarms
with the Antenna.
Set the AntennaSupervision Threshold in Branch B to 0 for all the sectors to
get rid of this alarm.
This is because the feeder cable is shared by the 1900 and the 850, and the
1900 powers the TMA (15V) through the jumper cables thus interfering with the
850 branch B antenna supervision readings (tests for DC resistance)
triggering the alarm.

ALARM 3: Loss of Cell Delineation


This can happen for the IMA link or the separate E1

Go to Top

Page 4

check status of E1s, their cross connection, configuration


check the link performance (ES and SES) on E1PhysPathTerm for that link, if
the numbers are increasing, then the network is not stable, if it is not
increasing, then there might be a HW issue (ET board)
ET port might be hanging, thus restart the port

ALARM 4: Carrier_RXDiversityLost
This alarm will cause a degraded carrier
check whether the RU or FU is locked
if connection is ok, try to restart the port for that sector "lhsh 001200/xxx
restart"
might be combined with antenna alarm (AiDevice_AntennaSystemProblem or
TmaDevice_AntennaSystemProblem)

ALARM 5: Device_AntennaSystemProblem or TmaDevice_AntennaSystemProblem


Which alarm shows up depends on whether the antenna is connected to a TMA
check the antenna, jumper cables, cable connections visually and also by
swapping them among the sectors and see whether alarm moves
check FU
check the value of the supervision parameter (should be 49, but if set to 0
no alarm is reported)
restart the RU

ALARM 6: Carrier_RejectSignalFromHardware
This alarm is issued from several HW, mainly RU, TXboard and RRU
insert new HW
if this doesnt help reboot the RBS (there has been a CSR which requires
reboot)

ALARM 7: RuDeviceGroup_GeneralHWError

Go to Top

Page 5

This alarm indicates problems with the component (written at beginning of


alarm, in this case RU)
restart RU port, restart whole RU board
if doesnt help, replace RU Cable between RU and FU disconnected - Plug back
in and restart boards with restart aux unit command

ALARM 8: Device_ExternalUnitFailure
This alarm appears if the feeder or jumper cable is connected incorrectly or
damaged or the TMA can be faulty
check the antenna, jumper cables, cable connections visually and also by
swapping them among the sectors and see whether alarm moves
check the TMA
ALARM 9: ExternalTma_LnaFailureBranchA
This alarm comes up when the two transistors amplifying the RF signals in the
TMA fail. The cell can still carry traffic as long as branch B is working,
however, the RX might be degraded.
=> run script to modify the TMA parameters
Make sure the currentHighLimA TMA parameter is set to 180 just like the
currentHighLimB.

ALARM 10: Nbap (in RNC) OR Equipment for RUDeviceGroup (in RBS)
Check with Moshell the equipment view for the RBS
Restart the specific RU/FU in RBS Subrack
ALARM 11: Carrier_UL_GainProblem
Check attenuation , RBS needs one of each, DPCL, TPA, TR
ALARM 12: Carrier_UL_GainTruncated
Check whether feeder loss is outside the acceptable range (max is 6db)
Check power
Are RU boards steady
ALARM 13: AuxPlugInUnit_PiuConnectionLost
Piu powered off? Cable problem?
FU/RU? => Check "cabx"

Go to Top

Page 6

EC BUS disconnected
Power to FCU was cut
ALARM 14: Tma_LnaFailure
Check voltage (what TMA gives out),
if too low => check FU (bad or short circuit) => restart FU
if 0 => check if internalpower is set to yes (in ExternalTma MO)
check current (what antenna pulls out) => c heck if also AiDevice (antenna)
alarm
ALARM 15: CLU_LossofMain
Lost power, node is in backup mode
ALARM 16: FCU_DeviceGroup_NumberofHWEntitiesMismatch
Was HW replaced? It then might have a different revision => restart
PluginunitMO for that piece
ALARM 17: FCU_DeviceGroup_FanFailure
1 FCU has fan, if enabled and unlocked, restart it
ALARM 18: RXDiversityLoss
Check if FU Is locked or the RX cable has been pulled out
ALARM 19: CarrierReject
If HSDPA is enabled, disable it, the alarm will then go away
ALARM 20: IMAGroupInsufficientLinks
IMAGroupInsufficientLinksatFarEnd
IMA is usually disabled, but IMA link is enabled
=> delete/recreate IMA, if that doesnt help,
=> or lock the active board (force it to go over to the redundant one),
unlock after (so it goes back)
=> or reset the processor on board
ALARM 21: PSUDeviceGroup_GeneralSWError
restart PSUDeviceGroup
ALARM 22: Carrier_SingalNotReceivedWithinTime

Go to Top

Page 7

i.e. Sector=1, Carrier=1


=> is TXboard up?
=> disable HSDPA, txdevicegroup on slot 10

ALARM 23: Bfu_BatteryChargingFailure


check voltage on battery, should be around 50V, if not "acc restartAuxUnit
AuxPlugInUnit" (from PS1)
ALARM 24: UtranCell_NbapMessageFailure (in RNC)
AIDevice_ExternalUnitFailure + CarrierRejectSignalFromHW (in RBS)
Check if antenna feeder is too low
Check FU
ALARM 25: UtranCell_NbapMessagefailure (RNC)
Ai_Device_ExternalUnitFailure (RBS, equipment malfunction, FU aidevice=1)
Carrier_RejectSignalFromHardware (RBS)
In RBS t&e: antennafeeder low/high
turn off TMA power
ALARM 26: RBS_LocalCellnotAdded (RNC) or NBapMessageFailure (RNC)
RBS has no alarms
cells are disabled, in RBS, txboard is down
ALARM 27: UtranCell_InternalResourceUnavailable or
UtranCell_NbapMessageFailure
workaround to reload the module where the RBS is
The module can be found in the properties of the RBS in EMAS under iub_links
in the Radio Network view.
Or it can be found using Moshell on the RNC
>pr iublink
Find the RBS in the list and do a get on it.
ALARM 28:Antenna alarms pointing to one sector

Go to Top

Page 8

To segregate whether the fault is in the feeder cable or the hardware, we


need to swap the feeder cable on FU from one sector to another and see if the
fault moves too. If Yes, then its definitely a fault in the Feeder cable. If
not, then the fault should be in the FU board and it should be replaced.
ALARM 29: ExternalTMA_degraded/Failed
Moshell <rbs>
cabx
# The cabx printout has PORT information at the end.
# For a 3 sector site there are 6 PORT information. One line for
# RU and FU devices (3 RU+3FU).
The printout shows the port, for example,
====================================
SMN APN PORT BOARD
====================================
0 12 port_0_dev_8 RU22
0 12 port_0_dev_8 FU
0 12 port_4_dev_9 RU22
0 12 port_4_dev_9 FU
0 12 port_8_dev_10 RU22
0 12 port_8_dev_10 FU
-----------------------------------lhsh 001200/port_x_dev_yy fui get devstat
# get port information from cabx
Ensure that the devstat printout from above has ~16000mV for each sector and
the current is between 50mA-200mA, if and only if the site has TMAs defined
and is being powered by the UMTS RBS (MO:externalTMA,
Attribute:internalpower).
Each RBS in the US market, has threshold when this alarm is generated. These
thresholds are input into the RBS using scripts. The thresholds vary for
single band TMAs and dual band TMAs. Make sure that the right threshold is
set for the type of TMA.
acc SystemConstants=1 writeConst
y
300
00001
acc SystemConstants=1 writeConst

Go to Top

Page 9

y
301
135
acc SystemConstants=1 writeConst
y
302
270
acc SystemConstants=1 writeConst
y
303
135
acc SystemConstants=1 writeConst
y
304
270

ALARM 30: Carrier Diversity Failed/Degraded


In the RBS antenna branch A is TX/RX while branch B is RX only. Hence there
are two RX paths (RX diversity). The RBS monitors the two RX paths and
compares the signal received from both of these paths. If there is
significant "mismatch" between these paths (like TMA failure on branch B.
Remember branch B has no supervision) then this alarm is generated.
This alarm is suppressed if there is a higher priority alarm such as the
AI_Device_antenna_system_problem. Give lgar command in moshell to see if this
alarm was raised and suppressed.
ALARM 31: IMA UNUSABLE
Alarms on RBS
Symptom:
Warn IMA Link Reception Unusable at Far End remote_node_transmission_error
ImaGroup=1-1-ima1,ImaLink=3
Warn IMA Link Reception Unusable at Far End remote_node_transmission_error
ImaGroup=1-1-ima1,ImaLink=4
Warn IMA Link Transmit Unusable at Far End remote_node_transmission_error
ImaGroup=1-1-ima1,ImaLink=3
Warn IMA Link Transmit Unusable at Far End remote_node_transmission_error
ImaGroup=1-1-ima1,ImaLink=4

Go to Top

Page 10

Warn Remote Defect Indication on IMA Link remote_node_transmission_error


ImaGroup=1-1-ima1,ImaLink=3
Warn Remote Defect Indication on IMA Link remote_node_transmission_error
ImaGroup=1-1-ima1,ImaLink=4
Solution:
Make a cv on the RBS and cold restart RBS to clear alarms for imalink=3 and
imalink=4.
cvms <cv name> <user> <comment>
acc 0 restart
ALARM 32: Carrier_ULGainTruncated
Symptoms
The RBS sectors which have long feeder cables with feeder loss bigger than
6db get alarm Carrier_ULGainTruncated, Bad Coverage on UE
The parameter ulfeederAtteunation should be set according to the actual
feeder length, even if the feeder attenuation is greater than 6db.
The problem occurs at sites with feeder losses bigger than 6dB and it is the
entered feeder loss value that triggers this alarm.
The alarm doesn't point out a real error (except in the case that the
operator enters a value that are bigger than 6dB by mistake), its more of an
information that the feeder are large and performance can get degraded with
large feeder losses.
REMEDY:
This is a warning alarm issued when the UL amplification internally in the
RBS cannot compensate for the attenuation in the Antenna Feeder Cable.
Optimal sensitivity is no longer obtained.
Nothing in the RBS changes state because of this situation and trafic
handling continues. The external attenuation, that is the combination of the
gain of the TMA and the UL Attenuation of the Antenna Feeder
(AntFeederCable), is larger than what the Low Noice Amplifier (LNA) on the FU
can compensate for. When that situation arise, the alarm
Carrier_ULGainTruncated is issued.
Accept the presence of the warning alarm. The ulAttenuation of
AntennaFeederCable shall not be changed to a false value, as that impacts the
power measurements.
In most of the cases this alarm will be planned to be removed in a later sw
revision on the RBS.
ALARM 33: Loss of Tracking & Loss of Synch Reference Redundancy

RBS> alt

Go to Top

Page 11

1969-12-31 21:44:18 M Loss of Tracking replaceable_unit_problem


Synchronization=1
1969-12-31 21:45:18 w Loss of Synch Reference Redundancy
replaceable_unit_problem Synchronization=1
RBS> lpr sync
=============================================================================
=====
Proxy MO
=============================================================================
=====
102 Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu=1,TimingUnit=1,TuSyncRef=1
1035 TransportNetwork=1,Synchronization=1
1102 NodeBFunction=1,RBSxxxSynchronization=1
1164 NodeBFunction=1,Iub=RBS,NodeSynchTp=1
RBS> get 1035
==============================================================
1035 TransportNetwork=1,Synchronization=1
==============================================================
SynchronizationId 1
degradationIsFault 0 (degrNotFault)
syncRefActivity i[8] = 1 2 1 1 1 1 1 1
syncRefPriority i[8] = 1 2 0 0 0 0 0 0
syncRefStatus i[8] = 2 3 0 0 0 0 0 0
syncReference [8] =
>>> syncReference =
Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu=1,Etmc1=1,E1PhysPathTerm=pp1
>>> syncReference =
Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu=1,Etmc1=1,E1PhysPathTerm=pp2
>>> syncReference =
>>> syncReference =
>>> syncReference =
>>> syncReference =

Go to Top

Page 12

>>> syncReference =
>>> syncReference =
systemClockA 2 (lockedMode)
systemClockB 7 (notApplicable)
systemClockRedundancy 0 (SYSTEM_CLOCK_USERS_USE_PLANE_A)
userLabel
=============================================================================
=====
Total: 1 MOs
RBS> acl 1035
=============================================================================
=====
Proxy MO Action Nr of Params
=============================================================================
=====
1035 Synchronization=1 addSyncRefResource 2
1035 Synchronization=1 changeSyncRefPriority 2
1035 Synchronization=1 removeSyncRefResource 1
1035 Synchronization=1 resetLossOfTracking 1
=============================================================================
=====
RBS> acc 1035 resetLossOfTracking
=============================================================================
=====
1035 TransportNetwork=1,Synchronization=1
=============================================================================
=====
Are you Sure [y/n] ? y
=============================================================================
=====
Proxy MO Action Nr of Params
=============================================================================
=====

Go to Top

Page 13

1035 Synchronization=1 resetLossOfTracking 1


Parameter 1 of 1, syncReference (moRef-ManagedObject):
Enter mo LDN:
Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu=1,Etmc1=1,E1PhysPathTerm=pp1
>>> Return value = null
=============================================================================
=====Total: 1 MOs attempted, 1 MOs actioned
RBS> acc 1035 resetLossOfTracking
=============================================================================
=====1035 TransportNetwork=1,Synchronization=1
=============================================================================
=====
Are you Sure [y/n] ? y
=============================================================================
=====
Proxy MO Action Nr of Params
=============================================================================
=====
1035 Synchronization=1 resetLossOfTracking 1
Parameter 1 of 1, syncReference (moRef-ManagedObject):
Enter mo LDN:
Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu=1,Etmc1=1,E1PhysPathTerm=pp2
>>> Return value = null
=============================================================================
=====
Total: 1 MOs attempted, 1 MOs actioned
RBS> alt
Alarm should be gone.
ALARM 34: Switch Core Fault or PsDevice_LossOfMains
Several ASPs lock sectors on their end. However, when they do so, some of
them will block other components by chance. This will throw alarms such as
the ones mentions above.
Switch Core Fault: they blocked one of the redundancy slots.
PsDevice_LossOfMains: they tampered with the PCU.

Go to Top

Page 14

ALARM 35: RbsLocalCell_ConfiguredLimitExceedsLicensedLimit unavailable


The cell range isnt set prorerly.
Block the cells on the RNC
On the RBS, set the cell range with command set cell cellrange 35000
For e.g
RBS> alt
Starting to retrieve active alarms
Nr of active alarms are: 23
=============================================================================
=======================================
Date & Time (Local) S Specific Problem MO (Cause/AdditionalInfo)
=============================================================================
=======================================
2012-08-08 16:40:39 m Emergency Unlock of Software Licensing Licensing=1
(Emergency state is activated)
2012-08-08 16:40:40 C License Key File Fault Licensing=1 (No license key file
installed.)
2012-08-15 09:35:59 M EulForLargeRbsConfigLicenseNotValid NodeBFunction=1
(unavailable)
2012-08-15 09:35:59 M NodeBFunction_16QamLicenseNotValid NodeBFunction=1
(unavailable)
2012-08-15 09:35:59 M RbsLocalCell_MaxNumEulUsersExceedsLicensedLimit
RbsLocalCell=S3C1 (unavailable)
2012-08-15 09:35:59 M NodeBFunction_HsdpaFlexibleSchedulerLicenseNotValid
NodeBFunction=1 (unavailable)
2012-08-15 09:35:59 M RbsLocalCell_MaxNumHsdpaUsersExceedsLicensedLimit
RbsLocalCell=S2C1 (unavailable)
2012-08-15 09:35:59 M RbsLocalCell_MaxNumHsdpaUsersExceedsLicensedLimit
RbsLocalCell=S1C1 (unavailable)
2012-08-15 09:35:59 M RbsLocalCell_MaxNumHsPdschCodesExceedsLicensedLimit
RbsLocalCell=S3C1 (unavailable)
2012-08-15 09:35:59 M RbsLocalCell_MaxNumHsPdschCodesExceedsLicensedLimit
RbsLocalCell=S2C1 (unavailable)
2012-08-15 09:35:59 M RbsLocalCell_MaxNumHsPdschCodesExceedsLicensedLimit
RbsLocalCell=S1C1 (unavailable)

Go to Top

Page 15

2012-08-15 09:35:59 M RbsLocalCell_MaxNumEulUsersExceedsLicensedLimit


RbsLocalCell=S2C1 (unavailable)
2012-08-15 09:35:59 M NodeBFunction_HsdpaDynamicCodeAllocationLicenseNotValid
NodeBFunction=1 (unavailable)
2012-08-15 09:35:59 M NodeBFunction_DlPowerControlEulLicenseNotValid
NodeBFunction=1 (unavailable)
2012-08-15 09:35:59 M RbsLocalCell_MaxNumEulUsersExceedsLicensedLimit
RbsLocalCell=S1C1 (unavailable)
2012-08-15 09:35:59 M
NodeBFunction_HsdpaImprovedLinkAdaptationLicenseNotValid NodeBFunction=1
(unavailable)
2012-08-15 09:35:59 M RbsLocalCell_MaxNumHsdpaUsersExceedsLicensedLimit
RbsLocalCell=S3C1 (unavailable)
2012-08-15 09:35:59 M EnhUeDrxLicenseNotValid NodeBFunction=1 (unavailable)
2012-08-15 09:35:59 M NodeBFunction_EnhancedLayer2LicenseNotValid
NodeBFunction=1 (unavailable)
2012-08-15 09:35:59 M HsFachLicenseNotValid NodeBFunction=1 (unavailable)
2012-08-15 09:35:59 M NodeBFunction_HsdpaIncrementalRedundancyLicenseNotValid
NodeBFunction=1 (unavailable)
2012-08-15 09:35:59 M IncrNumHsCodesLicenseNotValid NodeBFunction=1
(unavailable)
2012-08-15 09:35:59 M NodeBFunction_64QamLicenseNotValid NodeBFunction=1
(unavailable)
>>> Total: 23 Alarms (1 Critical, 21 Major)
About :
When there is a total power outage to the node, it will roll its time stamp
back to the original timestamp which is of the year 1970. The license keys,
however, has a valid date of the date when it was ordered, which usually is
recent. And as a result the licence keys become invalid. Symptoms will be
that there are many licence keys alarms and the node will stop carrying
traffic.
Conditions :
:
Node not carrying traffic
Timestamp shows date like this 01-01-1970 (most of the cases)
Cold restart will not help to set the time correctly.
PROCEDURE:

Go to Top

Page 16

:
Activate emergency unlock keys on the licenses
Set the node to the correct recent timestamp. Refer to the RNC for correct
timestamp.
Alarm would be gone.

: ::
: ::
ALARM 36: Node Status Analyzer doesnt open
If you get the following error when opening "NODE STATUS ANALYZER" to view
cell activity remotely:
"mismatch: struct IDL:Configuration/DataTypes/UndefinedValue:1.0
UndefinedValue{long dummy} != string[0] vmcid: 0x0 minor code: 0
completed: No
Please run the Iub consistency report on the RNC.
How to open NODE STATUS ANALYZER:
In WCDMA RAN Explorer, Select the RBSRight click on itGo to "Tools"Select
"Node Status Analyzer"
How to run the Iub consistency report:
In WCDMA RAN Explorer, Select the RNC that RBS belongs toRight click on
itGo to "Consistency"Select "IUB Consistency Report"

# The cabx printout has PORT information at the end.# For a 3 sector site
there are 6 PORT information. One line for# RU and FU devices (3 RU+3FU).
# The cabx printout has PORT information at the end.# For a 3 sector site
there are 6 PORT information. One line for# RU and FU devices (3 RU+3FU).#
The cabx printout has PORT information at the end.# For a 3 sector site there
are 6 PORT information. One line for# RU and FU devices (3 RU+3FU).
ALARM 37: RfCable_Disconnected equipment_malfunction
Due to the TX plugin from FU board being disconnected.
Plug it back in.
A restart of the plugin unit may be required to eliminate the alarm.

ALARM 38: loss_of_signal


ET 1-2 connector pulled out

Go to Top

Page 17

ALARM 39: TU Synch Reference Loss of Signal loss_of_signal


TU Synch Reference Loss of Signal loss_of_signal
Probable cause: TimingUnit=1,TuSyncRef=1 is unlocked but disabled.
Solution: Lock the TimingUnit=1,TuSyncRef=1 so that it is locked and
disabled.
RBSXXXX> alt

Starting to retrieve active alarms


Nr of active alarms are: 1
=============================================================================
===================
Date & Time (Local) S Specific Problem Cause Mo-Reference
=============================================================================
===================
2007-09-20 01:33:03 M TU Synch Reference Loss of Signal loss_of_signal
Subrack=1,Slot=1,PlugInUnit=1,Cbu=1,TimingUnit=1,TuSyncRef=1
>>> Total: 1 Alarms (0 Critical, 1 Major)
When u see this alarm, do a lst on TimingUnit=1,TuSyncRef=1:
RBSXXXX> lst TimingUnit=1,TuSyncRef=1
=============================================================================
======
Proxy Adm State Op. State MO
=============================================================================
======
136 1 (UNLOCKED) 0 (DISABLED)
Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu=1,TimingUnit=1,TuSyncRef=1
=============================================================================
======
Total: 1 MOs
If it is unlocked like in the above state, than that is the cause of the
alarm, the reson of the alarm is that the RBS are getting their
synchronisation signal from the E1s and not from the timing unit by gps. So

Go to Top

Page 18

if this mo is unlocked it is expecting a sync signal that it is not getting


so it thinks that the source of sync just droped and it lost the signal,
hence the alarm.
Lock that MO and the alarm should clear.
RBSXXXX> lbl 136
=============================================================================
======
Proxy Adm State Op. State MO
=============================================================================
======
136 0 (LOCKED) 0 (DISABLED)
Equipment=1,Subrack=1,Slot=1,PlugInUnit=1,Cbu=1,TimingUnit=1,TuSyncRef=1
=============================================================================
======
Total: 1 MOs
There should be no alarms left:
RBSXXXX> alt
Starting to retrieve active alarms
Nr of active alarms are: 0
=============================================================================
===================
Date & Time (Local) S Specific Problem Cause Mo-Reference
=============================================================================
===================
>>> Total: 0 Alarms (0 Critical, 0 Major)
TO finish, It is very important to create a cv and set it as startable.
ALARM 40:
AuxPlugInUnit_NewAuxiliaryUnitDetectedNotCorrespondingToTheDefinedConfigurati
on
While doing DUW integration for 6K series nodes we faces issues about sectors
not coming up in the node.
When you face such kind of alarm just ask your FE to follow the below
steps ::
1. Ask FE to export & delete scripts while running the Cesar ftp on his
computer.

Go to Top

Page 19

2. After that restart the DUW & RRUWs.


Note
:: When you export and delete that does not delete the CVs that were
previously created, it will re-create basic CVs again.
Alarms should be gone now.

Go to Top