Anda di halaman 1dari 17

(E) ADJACENT PROPERTY:

623 VALENCIA STREET, BLOCK


3576/LOTS 078
1 STORY COMMERCIAL

50 CLARION & 84
SYCAMORE
BLOCK 3576/LOTS 077
4 STORIES

100' - 0"

80-82 SYCAMORE
BLOCK 3576/ LOT
076
3 STORIES

645-647 VALENCIA STREET


ADDITIONS AND ALTERATIONS TO AN EXISTING 2-STORY STRUCTURE

26' - 0"

SYCAMORE ST.

VALENCIA ST.

80' - 0" (LOT DEPTH)


15' - 0"

13' - 0"

VARIANCE
APPLICATION
5-10-16
EE#: 20151339E

F
PORTION OF BUILDING SUBJECT TO HEIGHT RESTRICTIONS
PER SECTION 261.1(d)(2)

26' - 3 1/2"

5' - 8 1/2"

20' - 0"
(25% LOT DEPTH)

EXISTING CORNICE TO REMAIN

6' - 8"

P.L.

SIDEWALK

10' - 0"

(N) CURB CUT

P.L.

+24'- 1/2"

2
PRIVATE DECK @ 5TH FLOOR

PRIVATE DECK BELOW


@ 4TH FLOOR

PRIVATE DECK
@ 3RD FLOOR
+55'-0"

15' - 8"

ADJACENT
PROPERTY
REAR YARD
(LOT4 114-116)

ROOF OVER 5TH FLOOR

8' - 7"

+60'-2"

SUBJECT PROPERTY:
645-647 VALENCIA STREET
BLOCK 3576/LOT 062
5 STORIES

645-647
VALENCIA ST.

(E) ADJACENT
PROPERTY:
2 LEXINGTON
4 LEXINGTON
85 SYCAMORE STREET
BLOCK3576/LOTS 114116
4 STORIES

(E) TREE IN
CENTER OF
SIDEWALK TO
BE REMOVED

+44'-8 1/4"

15' - 0 1/2"

35' - 0" (LOT WIDTH)

PORTION OF
PROPOSED ADDITIONS
SUBJECT TO REAR
YARD VARIANCE SHOWN SHADED

6' - 5 1/2"

+34'-4 1/2"

8' - 6"

5' - 9"

5' - 0"

1
5' - 0"

NEW STREET
TREES EVERY 20'
PER S.138.1(c)(1)
TYP.

Revisions

VARIANCE
APPLICATION:
PREVIOUS APPS
BPA#2015.0305.0103
EE#2015.1339E

+/- 19' - 8"


(REARYARD)

ELEVATOR
PENTHOUSE

STAIR PENTHOUSE

7
+/+19'-3"

NO REAR YARD @
657 VALENCIA

(E) ADJACENT PROPERTY:


657 VALENCIA STREET, BLOCK/LOT 061
1 STORY/FULL LOT COVERAGE

3576/ 062

10' - 6"

(REAR YARD)

NOTICE

12 LEXINGTON ST.
14 LEXINGTON ST.
BLOCK 3576/LOT
046
3 STORIES
N

PROPOSED SITE PLAN

0' 2' 4'

1/8" = 1'-0"

8'

647 VALENCIA STREET

16'

OWNER:

ABBREVIATIONS:

GENERAL LEGEND:

SHEET INDEX

BUILDING DATA:
PROJECT ADDRESS:

#
@
AB
ADJ
ALT
AFF
APPROX
ASPH

NUMBER
AT
ANCHOR BOLT
ADJACENT
ALTERNATE
ABOVE FINISH FLOOR
APPROXIMATE
ASPHALT

BLDG
BTWN
BOT

BUILDING
BETWEEN
BOTTOM

CAB
CEM
CLR
CMU
COL
CONT
CTR
CL
CER
CLG
CONC

CABINET
CEMENT
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONTINUOUS
CENTER
CENTER LINE
CERAMIC
CEILING
CONCRETE

DBL
DEPT
DIA
DF
DH
DIM
DN
DS
DTL
DWG

DOUBLE
DEPARTMENT
DIAMETER
DOUGLAS FIR
DOUBLE HUNG
DIMENSION
DOWN
DOWNSPOUT
DETAIL
DRAWING

(E)
EA
ELEC
EL
EQ
EXT

EXISTING
EACH
ELECTRICAL
ELEVATION
EQUAL
EXTERIOR

FDN
FIN
FLR
FLUOR
FOC
FOS
FTG
FOF
GALV
GFIC
GND
GYP
GWB
HORZ
HT
INSUL
INT

FOUNDATION
FINISH
FLOOR
FLUORESCENT
FACE OF CONCRETE
FACE OF STUD
FOOTING
FACE OF FINISH
GALVANIZED
GROUND FAULT
INTERRUPT CIRCUIT
GROUND
GYPSUM
GYPSUM WALL BOARD
HORIZONTAL
HEIGHT
INSULATION
INTERIOR

JT
LAV
MAX
MIN
MFR
MTL

JOINT
LAVATORY
MAXIMUM
MINIMUM
MANUFACTURER
METAL

(N)
NIC
NO/#
NTS

NEW
NOT IN CONTRACT
NUMBER
NOT TO SCALE

OC
OPNG
OPP

ON CENTER
OPENING
OPPOSITE

PL
PLY
PTDF

PROPERTY LINE
PLYWOOD

PLAM
PTD
PTN

PRESSURE TREATED DOUGLAS FIR


PLASTIC LAMINATE
PAINTED
PARTITION

R
REF
REFR
RWD
REINF
RO
RWL
REQ
SIM
SHT
SOG
SPEC
STD
STRL
SUSP
SYM

RISER
REFERENCE
REFRIGERATOR
REDWOOD
REINFORCED
ROUGH OPENING
RAIN WATER LEADER
REQUIRED
SIMILAR
SHEET
SLAB ON GRADE
SPECIFICATION
STANDARD
STRUCTURAL
SUSPENDED
SYMMETRICAL

TRD
T&G

TREAD
TONGUE AND GROOVE

THK
TOS
TP
TB
TYP

TRICK
TOP OF SLAB
TOILET PAPER
TOWEL BAR
TYPICAL

UON

UNLESS OTHERWISE NOTED

VERT
VIF
VPFAM
W/
W/O
WC
WDW
WP
WT
WD
WH

VERTICAL
VERIFY IN FIELD
VAPOR PERMEABLE FLUID
APPLIED MEMBRANE
WITH
WITHOUT
WATER CLOSET
WINDOW
WATERPROOF
WEIGHT
WOOD
WATER HEATER

G0.01
G0.02
A101

EXTERIOR ELEVATION

A101

COLUMN LINE

ELEVATION MARKER

CENTER LINE

PROPERTY LINE

BLOCK/ LOT:

BLDG / WALL SECTION

ARCHITECTURAL SITE PLAN- ROOF


GENERAL NOTES, AND GENERAL REQUIREMENTS

SS0.1

SITE SURVEY

A0.11
A0.12
A0.13
A0.14
A0.15

EXISTING FIRST FLOOR PLAN


EXISTING SECOND FLOOR PLAN
EXISTING NORTH ELEVATION
EXISTING EAST & WEST ELEVATIONS
EXISTING SOUTH ELEVATIONS

A1.01
A1.02
A1.03
A1.04

FIRST FLOOR PLAN


SECOND AND THIRD FLOOR PLANS
FOURTH AND FIFTH FLOOR PLANS
ROOF PLAN

A2.01
A2.02
A2.03

NORTH ELEVATION
EAST & WEST ELEVATION
SOUTH ELEVATION

A3.01
A3.02

EAST (REAR) SECTION


BLDG SECTION

ZONING DISTRICT:
LOT SIZE:
SFBC OCCUPANCY CLASS:
CONSTRUCTION TYPE:
ARCHITECT:

DENNIS & SUSAN RING


TEL: (415) 298 5133
645-647 VALENCIA STREET
SAN FRANCISCO, CA 94110
BLOCK 3576/ LOT 062
VALENCIA-NCT 55-X
2800 SQ FT
R-2 RESIDENTIAL, M MERCANTILE, U PARKING
TYPE III

The Contractor shall verify all


existing conditions. Written
dimensions take preference over
scaled dimensions and shall be
verified on the project site. Any
discrepancy shall be brought to
the attention of Kerman Morris
Architects prior to the
commencement of any work.
These drawings are an industry
standards builders set for
building permit and to assist the
contractor in construction. The
drawings show limited and only
representative/typical details.
All attachments, connections,
fastenings,etc, are to be properly
secured in conformance with
best practice, and the Contractor
shall be responsible for providing
and installing them.

KERMAN MORRIS ARCHITECTS, LLP


139 NOE STREET
SAN FRANCISCO, CA 94114
T: (415) 749 0302

DESCRIPTION OF WORK:
THE WORK CONSISTS OF PRESERVING AND RENOVATING THE EXISTING 2-STORY COMMERCIAL STRUCTURE AT
645-647 VALENCIA STREET AND CONSTRUCTING A NEW 3-STORY ADDITION OVER IT, FOR A TOTAL HEIGHT OF 5STORIES OR 55 TALL. THE RENOVATED ADDITION/ALTERATION BUILDING WILL BE A MIXED USE STRUCTURE
CONSISTING OF GROUND FLOOR COMMERCIAL, A RESIDENTIAL ENTRY AND PARKING FOR SOME OF THE UNITS
ACCESSED FROM SYCAMORE STREET. THE UPPER 4 STORIES WILL HOUSE (7) DWELLING UNITS. REAR YARD
AND OPEN SPACE VARIANCES ARE REQUIRED.
ALL WORK TO COMPLY WITH CURRENT LOCAL AND STATE CODES INCLUDING BUT NOT LIMITED TO: THE 2013
EDITION OF THE CALIFORNIA BUILDING CODE, THE CALIFORNIA PLUMBING CODE, THE CALIFORNIA MECHANICAL
CODE, THE CALIFORNIA ELECTRICAL CODE AND THE CALIFORNIA FIRE CODE, THE CURRENT EDITIONS OF THE
SAN FRANCISCO BUILDING AND PLANNING CODES, TITLE-24 ENERGY STANDARDS, ETC

WALL TYPE PARTITION

SITE PLAN

DATE

04/27/16

SCALE

As indicated

DRAWN BY

CG, SN, VD

CHECKED BY

TITLE 24 COMPLIANCE:
1

These drawings and


specifications are the property
and copyright of Kerman/Morris
Architects and shall not be used
on any other work except by
written agreement with
Kerman/Morris Architects.

KEYNOTE

JOB NO.

TM
1304

TITLE-24 MANDATORY MEASURES:


ALL WORK TO COMPLY WITH TITLE-24 MANDATORY MEASURES INCLUDING BUT NOT LIMITED TO: R-19 MIN.
INSULATION IN ALL NEW/REBUILT EXTERIOR WALLS; R-30 MIN. INSULATION IN ALL NEW/REBUILT ROOFS; R-19
RAISED FLOOR INSULATION IN ALL NEW/REBUILT WOOD FRAMED FLOORS; DOUBLE INSULATED DOORS AND
WINDOW PRODUCTS WITH CERTIFIED U-VALUE AND INFILTRATION CERTIFICATION; EXTERIOR DOORS AND
WINDOWS WEATHER-STRIPPED; ALL JOINTS AND PENETRATIONS CAULKED AND SEALED: 50% MINIMUM HIGH
EFFICACY LIGHTING IN KITCHENS (SEPARATELY SWITCHED); HIGH EFFICACY LIGHTING IN BATHROOMS,
GARAGE, LAUNDRY ROOM AND UTILITY ROOMS (OR MANUAL-ON OCCUPANCY SENSOR); ALL OTHER ROOMS,
LIGHTING TO BE HIGH EFFICACY, MANUAL-ON OCCUPANCY SENSOR, OR DIMMER. ALL RECESSED
INCANDESCENT CEILING FIXTURES TO BE IC APPROVED.

G0.01

UNIT COUNT (COMPLIES WITH S.207.6(c)(2)

PROJECT NOTES (cont.)

PROJECT NOTES

Article 2: Use Districts (Voluntary Compliance):

Project Location: 647/645 Valencia Street, Block 3576/Lot 062

LEVEL

STUDIO

1 BR

2 BR

3 BR

TOTAL

Sec. 207.6 REQUIRED MINIMUM DWELLING UNIT MIX IN NCT DISTRICT


Valencia NCT:

LOT SIZE: 35'X80' = 2,800 SF

FIRST FLOOR

SECOND FLOOR

S. 207.6(c)(2): 40% 2-Bedroom units required (3 units) required. Building


complies with (2) 2-Bedroom units and (1) 3-Bedroom units for a total of
43% large units.

THIRD FLOOR

FOURTH FLOOR

FIFTH FLOOR

TOTAL

7 UNITS

PERCENTAGE %

57% (STUDIO & 1 BR)

Zoning District: Valencia NCT

Sec. 261.1(d)(1) Alleys: Full height limit is allowed for the first 60' of depth
along
Sycamore Street (an alley) Beyond 60', building height is limited by 45
degree sun
access plane for this Southern side of East-West Sycamore Street per S.F.
Planning Code Section 261.1(d)(2). Building Complies

Building Height Limit: 55-X


Height limit: 55 feet maximum: 55'-0" proposed.
Proposed Building Use:
Addition and Alteration
Mixed use ground floor commercial 7 unit residential building, with
ground floor parking. Private roof decks are provided for some units. Rear yard and open space variance are
required.
Article 1.2: Dimensions Areas and Open Space

Sec. 415.3(a) INCLUSIONARY UNITS


Developments of less than 10 dwelling units are exempt from inclusionary
housing
requirements. Project exempt.

GROSS BUILDING SQUARE FOOTAGE:

Sec. 423.3 EASTERN NEIGHBORHOODS IMPACT FEE


Project is subject to fees for Tier 1 Projects.

BY FLOOR( ENCLOSED AREA):


1ST FLOOR

2,730 SF

2ND FLOOR

2,803 SF

3RD FLOOR

1,953 SF

4TH FLOOR

1,825 SF

5TH FLOOR

1,153 SF

TOTAL

Article 7: Neighborhood Commercial Districts


Sec. 726.1 VALENCIA STREET NCT DISTRICT - Density
No housing density requirements apply.

622 SF
1,171 SF

RESIDENTIAL (UNITS):

8,671 SF

TOTAL

10,464 SF

FLOOR

RESIDENTIAL UNIT- 1

SECOND FLOOR

Sec. 135 USABLE OPEN SPACE, NCT VALENCIA


Valencia Street NC-3: (Table 135A): A minimum of 80 square feet private area/unit or 107 square feet common
open space per unit required. (2) of the (7) proposed dwelling units have complying private open space.
(5) dwelling units require open space variance.
Sec. 136 OBSTRUCTIONS OVER STREETS, ALLEYS AND IN REQUIRED
SETBACKS.
Valencia Street NCT: Obstructions such as bays are allowed per section 136.
Sec. 140: DWELLING UNITS IN ALL USE DISTRICTS TO FACE ON AN OPEN
AREA. (Dwelling unit exposure). All units face onto public way. Building complies.

Article 1.5: Off-Street Parking and Loading

UNIT NET SQUARE FOOTAGE


UNIT NUMBER

Sec. 134 REAR YARDS


s. 134(a)(1)(B): 25% of lot depth (20') at the second story and each succeeding story of the building (and at any
residential level).
s. 134(b): Obstructions such as bays are allowed per section 136. Proposed 15' rear yard at second floor and
above. Project subject to rear yard variance or modification per section 134 (e).

Sec. 145.1 STREET FRONTAGES, NC DISTRICTS


Valencia NCT:
s. 145.1(c)(2): Parking: Garage entry to be no more than 1/3 of the lot width (or 26 feet) along Sycamore Street.
Building complies.
s. 145.1(c)(3): Active Uses: With the exception of driveway, building egress and mechanical access, the first 25
of the building depth at grade to be reserved for active uses. Building complies.
s. 145.1(c)(4)(B): Ground Floor Ceiling Height: Ground floor non-residential uses to have a minimum floor to floor
height of 14 feet as measured from grade.
For existing structure does not apply.
s. 145.1(c)(5): Street Facing Ground-Level Spaces: Floors of street fronting interior spaces are to be as close as
possible to sidewalk elevations. Building complies as commercial is proposed at grade.
s. 145.1(c)(6): Transparency and Fenestration: Street frontage on ground floor to have minimum 60% transparent
windows and doors. For existing structure does not apply.
Sec. 145.4 REQUIRED GROUND FLOOR COMMERCIAL USES
s. 145.4(b)(13)Valencia NCT: Ground floor along Valencia Street to be active uses and per 145.4(d)(3) no
commercial frontage to be more than 75 contiguous linear feet. Building Complies with small commercial unit
proposed.

BY USE( ENCLOSED AREA):

PARKING/ GARAGE:

Sec. 132 FRONT SETBACKS


None required for zoning district

Sec. 138.1(c)(1)and Article 16 STREET TREES


Street trees are required for projects of new construction and a minimum of (1) tree of 24 box size for each 20
feet of frontage of the property along the streets. Street trees to be compliant with the applicable water use
requirements of the Administrative Code Chapter 63 and species and locations are subject to approval by the
Department of Public Works. Installation, maintenance and protection of trees are subject to Article 16 of Public
Works Code. Complying street trees are provided and comply with this section.

10,464 SF

RETAIL/ COMMERCIAL:

Sec. 260: HEIGHT LIMITS: MEASUREMENT


Building height is measured from one point on the street frontage from curb
to top
of flat roof.
Article 4: Development Impact Fees

43% (2 BR +)

AREA

Sec. 151.1 SCHEDULE OF PERMITTED PARKING


Valencia NCT:
Residential: No parking is required. However 0.5 parking spaces per dwelling units are permitted on 7 x 0.5 = 3.5
= 4 spaces per section 153(a)(5). 4 spaces proposed. Project complies.

727 sq ft

Commercial Uses: Per Table 151 No parking is required where commercial is less
than 5,000 SF occupied floor area: No parking proposed. Project complies.

RESIDENTIAL UNIT- 2

SECOND FLOOR

670 sq ft

Sec. 152 REQUIRED LOADING SPACES:


None required for Commercial areas less than 10,000 square feet. None provided.

RESIDENTIAL UNIT- 3

SECOND FLOOR

701 sq ft

Sec. 154 DIMENSIONS FOR OFF-STREET PARKING


Valencia NCT: s. 154(a)(3) no minimum area or dimension requirements.

RESIDENTIAL UNIT- 4

THIRD FLOOR

486 sq ft

RESIDENTIAL UNIT- 5

THIRD FLOOR

875 sq ft

Sec. 155.2 BICYCLE PARKING REQUIRED


Residential Uses: s. 155.5 parking spaces for Residential Uses: one (1) Class 1
space for every dwelling unit. (7) dwelling units = (7) spaces required.
Total bicycle parking required = 7 spaces.
Total bicycle parking provided = 7 spaces. Building Complies.

RESIDENTIAL UNIT- 6

FOURTH FLOOR

909 sq ft

Sec. 166 CAR SHARING


Per Table 166, no car share spaces are required for 0-49 residential units. Building complies.

RESIDENTIAL UNIT- 7

FIFTH FLOOR

NET RESIDENTIALSQ.FT:

Sec. 168 BABY DIAPER CHANGING ACCOMODATIONS


Every Public-Serving Establishment shall provide baby diaper-changing accommodations. Commercial unit
complies.

645-647
VALENCIA ST.
VARIANCE
APPLICATION:
PREVIOUS APPS
BPA#2015.0305.0103
EE#2015.1339E

3576/ 062

NOTICE
These drawings and
specifications are the property
and copyright of Kerman/Morris
Architects and shall not be used
on any other work except by
written agreement with
Kerman/Morris Architects.
The Contractor shall verify all
existing conditions. Written
dimensions take preference over
scaled dimensions and shall be
verified on the project site. Any
discrepancy shall be brought to
the attention of Kerman Morris
Architects prior to the
commencement of any work.
These drawings are an industry
standards builders set for
building permit and to assist the
contractor in construction. The
drawings show limited and only
representative/typical details.
All attachments, connections,
fastenings,etc, are to be properly
secured in conformance with
best practice, and the Contractor
shall be responsible for providing
and installing them.

5,746 sq ft

PRIVATE OPEN SPACE PROVIDED:


(NO COMMON O.S)
UNIT #

1,378 sq ft

Revisions

Article 2.5: Height and Bulk Districts

FLOOR

2ND

2ND

2ND

3RD

3RD

4TH

PROJECT NOTES

OPEN SPACE SF
DATE

04/27/16

SCALE
DRAWN BY

CG, SN

CHECKED BY

4TH/ 5TH

TM

49.1 SF
(NOT COMPLY W/ MIM
PRIVATE O.S. REQUIREMENT
PER PLANING)

JOB NO.

1304

686.4 SF

708.1 SF

G0.02

DEMOLITION CALCULATIONS TABLE

DEMOLITION PERCENTAGES:
INTERIOR STRUCTURAL FRAMEWORK & FLOOR
PLATES
FLOOR

TOTAL (E) SQ. FTG.


FLOOR PLATE

DEMOLISHED SQ. FTG.


FLOOR PLATE

PERCENTAGE

1ST

NA

NA

NA

2ND

2645

0%

TOTAL

2645

0%

WALL

TOTAL (E) LINEAR FEET


EXISTING WALL

DEMOLISHED LINEAR FEET


DEMO WALL

PERCENTAGE

1ST

267

233

87

2ND

120

120

100%

TOTAL

387

353

91%

Revisions

COMBINED TOTAL

NOTE: If removal and replacement of additional building elements considered beyond repair is required during
construction, contact the Planning Department immediately for review and approval. This includes floor framing,
sidewalls and other structural members not visible from the public right-of-way. Removal of elements beyond percentages
submitted above is considered a violation. If removal is beyond percentages outlined in Planning Code Section 1005, further
environmental review by the Planning Department is required.

(0% + 91%) / 2 = 45.6%

DEMOLITION PERCENTAGES: EXTERNAL WALLS


FACADE

TOTAL SQ. FTG.

DEMOLISHED SQ. FTG.

PERCENTAGE

NORTH

2052 sq ft

470 sq ft

23%

EAST

973 sq ft

407 sq ft

42%

SOUTH

2186 sq ft

149 sq ft

7%

WEST

832 sq ft

0 sq ft

0%

TOTAL

6043 sq ft

1026 sq ft

17%

645-647
VALENCIA ST.
VARIANCE
APPLICATION:
PREVIOUS APPS
BPA#2015.0305.0103
EE#2015.1339E

3576/ 062

NOTICE
CODE: SFPC SEC 1005.(f)
(f) FOR PURPOSES OF THIS ARTICLE 10, DEMOLITION SHALL BE DEFINED AS ANY ONE OF THE FOLLOWING:

(1) REMOVAL OF MORE THAN 25% OF THE SURFACE OF ALL EXTERNAL WALLS FACING A PUBLIC
STREET(S); OR
(2) REMOVAL OF MORE THAN 50% OF ALL EXTERNAL WALLS FROM THEIR FUNCTION AS ALL EXTERNAL
WALLS; OR
(3) REMOVAL OF MORE THAN 25% OF EXTERNAL WALLS FROM THEIR FUNCTION AS EITHER EXTERNAL
OR INTERNAL WALLS; OR
INTERIOR BEARING WALL TO BE REMOVED: 19'-5"
.

(4) REMOVAL OF MORE THAN 75% OF THE BUILDINGS EXISTING INTERNAL STRUCTURAL FRAMEWORK
OR FLOOR PLANS UNLESS THE CITY DETERMINES THAT SUCH REMOVAL IS THE ONLY FEASIBLE
MEANS TO MEET THE STANDARDS FOR SEISMIC LOAD AND FORCES OF THE LATEST ADOPTED
VERSION OF THE SAN FRANCISCO BUILDING CODE AND THE STATE HISTORICAL BUILDING CODE.

11'-10" LF

FINDINGS:
SFPC SEC 1005.(f)(1): PERCENTAGE OF EXTERNAL WALLS TO BE REMOVED (17%) FROM THEIR FUNCTION
AS EXTERNAL WALLS IS LESS THAN 50%. PROJECT COMPLIES.

SFPC SEC 1005.(f)(2): PERCENTAGE OF EXTERNAL WALLS TO BE REMOVED (17%) FROM THEIR FUNCTION
AS EXTERNAL WALLS IS LESS THAN 50%. PROJECT COMPLIES.

FIRST FLOOR:
TOTAL FLOOR PLATES (2645 SF)
TOTAL INTERNAL STRUCTURAL FRAMEWORK (267')
.

SFPC SEC 1005.(f)(3): PERCENTAGE OF EXTERNAL WALLS TO BE REMOVED (17%) FROM FUNCTION AS
EXTERNAL OR INTERNAL WALLS IS LESS THAN 25%. PROJECT COMPLIES.

INTERIOR BEARING WALL TO BE REMOVED: 64'


.

These drawings and


specifications are the property
and copyright of Kerman/Morris
Architects and shall not be used
on any other work except by
written agreement with
Kerman/Morris Architects.
The Contractor shall verify all
existing conditions. Written
dimensions take preference over
scaled dimensions and shall be
verified on the project site. Any
discrepancy shall be brought to
the attention of Kerman Morris
Architects prior to the
commencement of any work.
These drawings are an industry
standards builders set for
building permit and to assist the
contractor in construction. The
drawings show limited and only
representative/typical details.
All attachments, connections,
fastenings,etc, are to be properly
secured in conformance with
best practice, and the Contractor
shall be responsible for providing
and installing them.

SFPC SEC 1005.(f)(4): TOTAL "INTERNAL STRUCTURAL FRAMEWORK OR FLOORPLATES" TO BE REMOVED IS


LESS THAN 75% OF EXISTING. PROJECT COMPLIES.
3'-1" LF

7'-2" LF

6'-2" LF

5'-8" LF

5'-8" LF

PARTITION / DEMO LEGEND


7'-3" LF

WALL TO REMAIN

3'-1" LF
11" LF

DATE
27'-9" LF
14' LF

7'-3" LF

SN

CHECKED BY

TM

NON-STRUCT. WALL TO BE REMOVED

EXISTING/DEMOLITION FIRST FLOOR


PLAN
1/4" = 1'-0"

1/4" = 1'-0"

DRAWN BY

JOB NO.

04/27/16

STRUCT. WALL TO BE REMOVED

7'-9" LF

UP

14' LF

SCALE
14' LF

8'-8" LF

1'-9" LF

EXISTING/
DEMOLITION
FIRST FLOOR
PLAN

1304

FLOORPLATE / WALL AREA TO BE REMOVED


N
0'

1'

2'

4'

8'

A0.11

DEMOLITION CALCULATIONS TABLE

DEMOLITION PERCENTAGES:
INTERIOR STRUCTURAL FRAMEWORK & FLOOR
PLATES
FLOOR

TOTAL (E) SQ. FTG.


FLOOR PLATE

DEMOLISHED SQ. FTG.


FLOOR PLATE

PERCENTAGE

1ST

NA

NA

NA

2ND

2645

0%

TOTAL

2645

0%

WALL

TOTAL (E) LINEAR FEET


EXISTING WALL

DEMOLISHED LINEAR FEET


DEMO WALL

PERCENTAGE

1ST

267

233

87

2ND

120

120

100%

TOTAL

387

353

91%

Revisions

COMBINED TOTAL

NOTE: If removal and replacement of additional building elements considered beyond repair is required during
construction, contact the Planning Department immediately for review and approval. This includes floor framing,
sidewalls and other structural members not visible from the public right-of-way. Removal of elements beyond percentages
submitted above is considered a violation. If removal is beyond percentages outlined in Planning Code Section 1005, further
environmental review by the Planning Department is required.

CORNICE ABOVE TO
REMAIN

(0% + 91%) / 2 = 45.6%

DEMOLITION PERCENTAGES: EXTERNAL WALLS


FACADE

TOTAL SQ. FTG.

DEMOLISHED SQ. FTG.

PERCENTAGE

NORTH

2052 sq ft

470 sq ft

23%

EAST

973 sq ft

407 sq ft

42%

SOUTH

2186 sq ft

149 sq ft

7%

WEST

832 sq ft

0 sq ft

0%

TOTAL

6043 sq ft

1026 sq ft

17%

645-647
VALENCIA ST.
VARIANCE
APPLICATION:
PREVIOUS APPS
BPA#2015.0305.0103
EE#2015.1339E

3576/ 062

NOTICE
CODE: SFPC SEC 1005.(f)
(f) FOR PURPOSES OF THIS ARTICLE 10, DEMOLITION SHALL BE DEFINED AS ANY ONE OF THE FOLLOWING:

(1) REMOVAL OF MORE THAN 25% OF THE SURFACE OF ALL EXTERNAL WALLS FACING A PUBLIC
STREET(S); OR
(2) REMOVAL OF MORE THAN 50% OF ALL EXTERNAL WALLS FROM THEIR FUNCTION AS ALL EXTERNAL
WALLS; OR
(3) REMOVAL OF MORE THAN 25% OF EXTERNAL WALLS FROM THEIR FUNCTION AS EITHER EXTERNAL
OR INTERNAL WALLS; OR

20'-7" LF

(4) REMOVAL OF MORE THAN 75% OF THE BUILDINGS EXISTING INTERNAL STRUCTURAL FRAMEWORK
OR FLOOR PLANS UNLESS THE CITY DETERMINES THAT SUCH REMOVAL IS THE ONLY FEASIBLE
MEANS TO MEET THE STANDARDS FOR SEISMIC LOAD AND FORCES OF THE LATEST ADOPTED
VERSION OF THE SAN FRANCISCO BUILDING CODE AND THE STATE HISTORICAL BUILDING CODE.

FINDINGS:
SFPC SEC 1005.(f)(1): PERCENTAGE OF EXTERNAL WALLS TO BE REMOVED (17%) FROM THEIR FUNCTION
AS EXTERNAL WALLS IS LESS THAN 50%. PROJECT COMPLIES.

INTERIOR BEARING COLUMN TO BE


REMOVED

SFPC SEC 1005.(f)(2): PERCENTAGE OF EXTERNAL WALLS TO BE REMOVED (17%) FROM THEIR FUNCTION
AS EXTERNAL WALLS IS LESS THAN 50%. PROJECT COMPLIES.
.

INTERIOR BEARING COLUMNS


TO BE REMOVED:6'-11"

SFPC SEC 1005.(f)(3): PERCENTAGE OF EXTERNAL WALLS TO BE REMOVED (17%) FROM FUNCTION AS
EXTERNAL OR INTERNAL WALLS IS LESS THAN 25%. PROJECT COMPLIES.

These drawings and


specifications are the property
and copyright of Kerman/Morris
Architects and shall not be used
on any other work except by
written agreement with
Kerman/Morris Architects.
The Contractor shall verify all
existing conditions. Written
dimensions take preference over
scaled dimensions and shall be
verified on the project site. Any
discrepancy shall be brought to
the attention of Kerman Morris
Architects prior to the
commencement of any work.
These drawings are an industry
standards builders set for
building permit and to assist the
contractor in construction. The
drawings show limited and only
representative/typical details.
All attachments, connections,
fastenings,etc, are to be properly
secured in conformance with
best practice, and the Contractor
shall be responsible for providing
and installing them.

SFPC SEC 1005.(f)(4): TOTAL "INTERNAL STRUCTURAL FRAMEWORK OR FLOORPLATES" TO BE REMOVED IS


LESS THAN 75% OF EXISTING. PROJECT COMPLIES.

19'-1" LF

SECOND FLOOR:
TOTAL FLOOR PLATES (2645 SF)
TOTAL INTERNAL STRUCTURAL FRAMEWORK (120')

4' LF

10'-5" LF

13'-8" LF

PARTITION / DEMO LEGEND

EXISTING/
DEMOLITION
SECOND FLOOR
PLAN

DATE

04/27/16

WALL TO REMAIN
SCALE

1/4" = 1'-0"

19'-7" LF
5'-5" LF

7'-8" LF

9' LF

2'-5" LF

3'-5" LF

7'-8" LF

STRUCT. WALL TO BE REMOVED

DRAWN BY

SN

CHECKED BY

TM

JOB NO.

1304

NON-STRUCT. WALL TO BE REMOVED


N
0'

EXISTING/ DEMOLITION SECOND FLOOR


PLAN
1/4" = 1'-0"

1'

2'

4'

8'

FLOORPLATE / WALL AREA TO BE REMOVED

A0.12

DEMOLITION CALCULATIONS TABLE

DEMOLITION PERCENTAGES:
INTERIOR STRUCTURAL FRAMEWORK & FLOOR
PLATES
FLOOR

TOTAL (E) SQ. FTG.


FLOOR PLATE

DEMOLISHED SQ. FTG.


FLOOR PLATE

PERCENTAGE

1ST

NA

NA

NA

2ND

2645

0%

TOTAL

2645

0%

WALL

TOTAL (E) LINEAR FEET


EXISTING WALL

DEMOLISHED LINEAR FEET


DEMO WALL

PERCENTAGE

1ST

267

233

87

2ND

120

120

100%

TOTAL

387

353

91%

Revisions

COMBINED TOTAL

NOTE: If removal and replacement of additional building elements considered beyond repair is required during
construction, contact the Planning Department immediately for review and approval. This includes floor framing,
sidewalls and other structural members not visible from the public right-of-way. Removal of elements beyond percentages
submitted above is considered a violation. If removal is beyond percentages outlined in Planning Code Section 1005, further
environmental review by the Planning Department is required.

P.L.
,.

AREA TO BE DEMOLISHED SHOWN HATCHED:


DEMO AREA: 470 sq ft
TOTAL AREA: 2052 sq ft
DEMO %:
17% = 470 / 2052

(0% + 91%) / 2 = 45.6%

DEMOLITION PERCENTAGES: EXTERNAL WALLS

P.L.

FACADE

TOTAL SQ. FTG.

DEMOLISHED SQ. FTG.

PERCENTAGE

NORTH

2052 sq ft

470 sq ft

23%

EAST

973 sq ft

407 sq ft

42%

SOUTH

2186 sq ft

149 sq ft

7%

WEST

832 sq ft

0 sq ft

0%

TOTAL

6043 sq ft

1026 sq ft

17%

645-647
VALENCIA ST.
VARIANCE
APPLICATION:
PREVIOUS APPS
BPA#2015.0305.0103
EE#2015.1339E

3576/ 062

NOTICE
(E) T.O. Parapet
29' - 1 1/2"

(E) Roof
25' - 4"

CODE: SFPC SEC 1005.(f)


(f) FOR PURPOSES OF THIS ARTICLE 10, DEMOLITION SHALL BE DEFINED AS ANY ONE OF THE FOLLOWING:

(1) REMOVAL OF MORE THAN 25% OF THE SURFACE OF ALL EXTERNAL WALLS FACING A PUBLIC
STREET(S); OR
(2) REMOVAL OF MORE THAN 50% OF ALL EXTERNAL WALLS FROM THEIR FUNCTION AS ALL EXTERNAL
WALLS; OR
(3) REMOVAL OF MORE THAN 25% OF EXTERNAL WALLS FROM THEIR FUNCTION AS EITHER EXTERNAL
OR INTERNAL WALLS; OR

EXTERNAL WALLS TO REMAIN

(4) REMOVAL OF MORE THAN 75% OF THE BUILDINGS EXISTING INTERNAL STRUCTURAL FRAMEWORK
OR FLOOR PLANS UNLESS THE CITY DETERMINES THAT SUCH REMOVAL IS THE ONLY FEASIBLE
MEANS TO MEET THE STANDARDS FOR SEISMIC LOAD AND FORCES OF THE LATEST ADOPTED
VERSION OF THE SAN FRANCISCO BUILDING CODE AND THE STATE HISTORICAL BUILDING CODE.
FINDINGS:
SFPC SEC 1005.(f)(1): PERCENTAGE OF EXTERNAL WALLS TO BE REMOVED (17%) FROM THEIR FUNCTION
AS EXTERNAL WALLS IS LESS THAN 50%. PROJECT COMPLIES.

SECOND FLOOR
12' - 11 1/2"

SFPC SEC 1005.(f)(2): PERCENTAGE OF EXTERNAL WALLS TO BE REMOVED (17%) FROM THEIR FUNCTION
AS EXTERNAL WALLS IS LESS THAN 50%. PROJECT COMPLIES.
SFPC SEC 1005.(f)(3): PERCENTAGE OF EXTERNAL WALLS TO BE REMOVED (17%) FROM FUNCTION AS
EXTERNAL OR INTERNAL WALLS IS LESS THAN 25%. PROJECT COMPLIES.

These drawings and


specifications are the property
and copyright of Kerman/Morris
Architects and shall not be used
on any other work except by
written agreement with
Kerman/Morris Architects.
The Contractor shall verify all
existing conditions. Written
dimensions take preference over
scaled dimensions and shall be
verified on the project site. Any
discrepancy shall be brought to
the attention of Kerman Morris
Architects prior to the
commencement of any work.
These drawings are an industry
standards builders set for
building permit and to assist the
contractor in construction. The
drawings show limited and only
representative/typical details.
All attachments, connections,
fastenings,etc, are to be properly
secured in conformance with
best practice, and the Contractor
shall be responsible for providing
and installing them.

SFPC SEC 1005.(f)(4): TOTAL "INTERNAL STRUCTURAL FRAMEWORK OR FLOORPLATES" TO BE REMOVED IS


LESS THAN 75% OF EXISTING. PROJECT COMPLIES.

PARTITION / DEMO LEGEND

(E) NORTH
ELEVATION

WALL TO REMAIN
DATE

04/27/16

STRUCT. WALL TO BE REMOVED


SCALE

FIRST FLOOR
0"
NON-STRUCT. WALL TO BE REMOVED

1/4" = 1'-0"

DRAWN BY

CG

CHECKED BY

TM

JOB NO.

1304

FLOORPLATE / WALL AREA TO BE REMOVED

EXISTING/ DEMOLITION NORTH


ELEVATION
1/4" = 1'-0"

A0.13

P.L.

AREA TO BE DEMOLISHED SHOWN


HATCHED:
DEMO AREA: 408 sq ft
TOTAL AREA: 974 sq ft
DEMO %:
42% = 408 / 973

DEMOLITION CALCULATIONS TABLE


P.L.
.

(E) T.O. Parapet


29' - 1 1/2"

(E) Roof
25' - 4"

DEMOLITION PERCENTAGES:
INTERIOR STRUCTURAL FRAMEWORK & FLOOR
PLATES
FLOOR

TOTAL (E) SQ. FTG.


FLOOR PLATE

DEMOLISHED SQ. FTG.


FLOOR PLATE

PERCENTAGE

1ST

NA

NA

NA

2ND

2645

0%

TOTAL

2645

0%

WALL

TOTAL (E) LINEAR FEET


EXISTING WALL

DEMOLISHED LINEAR FEET


DEMO WALL

PERCENTAGE

1ST

267

233

87

2ND

120

120

100%

TOTAL

387

353

91%

Revisions

SECOND FLOOR
12' - 11 1/2"

COMBINED TOTAL

NOTE: If removal and replacement of additional building elements considered beyond repair is required during
construction, contact the Planning Department immediately for review and approval. This includes floor framing,
sidewalls and other structural members not visible from the public right-of-way. Removal of elements beyond percentages
submitted above is considered a violation. If removal is beyond percentages outlined in Planning Code Section 1005, further
environmental review by the Planning Department is required.

FIRST FLOOR
0"

EXISTING/ DEMOLITION EAST


ELEVATION

(0% + 91%) / 2 = 45.6%

DEMOLITION PERCENTAGES: EXTERNAL WALLS


FACADE

TOTAL SQ. FTG.

DEMOLISHED SQ. FTG.

PERCENTAGE

NORTH

2052 sq ft

470 sq ft

23%

EAST

973 sq ft

407 sq ft

42%

SOUTH

2186 sq ft

149 sq ft

7%

WEST

832 sq ft

0 sq ft

0%

TOTAL

6043 sq ft

1026 sq ft

17%

645-647
VALENCIA ST.
VARIANCE
APPLICATION:
PREVIOUS APPS
BPA#2015.0305.0103
EE#2015.1339E

1/4" = 1'-0"
3576/ 062

NOTICE
CODE: SFPC SEC 1005.(f)
(f) FOR PURPOSES OF THIS ARTICLE 10, DEMOLITION SHALL BE DEFINED AS ANY ONE OF THE FOLLOWING:

P.L.

P.L.
(1) REMOVAL OF MORE THAN 25% OF THE SURFACE OF ALL EXTERNAL WALLS FACING A PUBLIC
STREET(S); OR

NO AREA TO BE DEMOLISHED
DEMO AREA: 0 sq ft
TOTAL AREA: 832 sq ft
DEMO %:
0% = 0 / 832

(2) REMOVAL OF MORE THAN 50% OF ALL EXTERNAL WALLS FROM THEIR FUNCTION AS ALL EXTERNAL
WALLS; OR

(E) T.O. Parapet


29' - 1 1/2"

(3) REMOVAL OF MORE THAN 25% OF EXTERNAL WALLS FROM THEIR FUNCTION AS EITHER EXTERNAL
OR INTERNAL WALLS; OR

(E) Roof
25' - 4"

(4) REMOVAL OF MORE THAN 75% OF THE BUILDINGS EXISTING INTERNAL STRUCTURAL FRAMEWORK
OR FLOOR PLANS UNLESS THE CITY DETERMINES THAT SUCH REMOVAL IS THE ONLY FEASIBLE
MEANS TO MEET THE STANDARDS FOR SEISMIC LOAD AND FORCES OF THE LATEST ADOPTED
VERSION OF THE SAN FRANCISCO BUILDING CODE AND THE STATE HISTORICAL BUILDING CODE.
FINDINGS:
SFPC SEC 1005.(f)(1): PERCENTAGE OF EXTERNAL WALLS TO BE REMOVED (17%) FROM THEIR FUNCTION
AS EXTERNAL WALLS IS LESS THAN 50%. PROJECT COMPLIES.
SFPC SEC 1005.(f)(2): PERCENTAGE OF EXTERNAL WALLS TO BE REMOVED (17%) FROM THEIR FUNCTION
AS EXTERNAL WALLS IS LESS THAN 50%. PROJECT COMPLIES.
SFPC SEC 1005.(f)(3): PERCENTAGE OF EXTERNAL WALLS TO BE REMOVED (17%) FROM FUNCTION AS
EXTERNAL OR INTERNAL WALLS IS LESS THAN 25%. PROJECT COMPLIES.

These drawings and


specifications are the property
and copyright of Kerman/Morris
Architects and shall not be used
on any other work except by
written agreement with
Kerman/Morris Architects.
The Contractor shall verify all
existing conditions. Written
dimensions take preference over
scaled dimensions and shall be
verified on the project site. Any
discrepancy shall be brought to
the attention of Kerman Morris
Architects prior to the
commencement of any work.
These drawings are an industry
standards builders set for
building permit and to assist the
contractor in construction. The
drawings show limited and only
representative/typical details.
All attachments, connections,
fastenings,etc, are to be properly
secured in conformance with
best practice, and the Contractor
shall be responsible for providing
and installing them.

SFPC SEC 1005.(f)(4): TOTAL "INTERNAL STRUCTURAL FRAMEWORK OR FLOORPLATES" TO BE REMOVED IS


LESS THAN 75% OF EXISTING. PROJECT COMPLIES.
EXTERNAL WALLS TO REMAIN

SECOND FLOOR
12' - 11 1/2"

PARTITION / DEMO LEGEND

(E) EAST & WEST


ELEVATIONS

WALL TO REMAIN
DATE

STRUCT. WALL TO BE REMOVED

ALL EXTERNAL WALLS FACING


PUBLIC STREET TO REMAIN

NON-STRUCT. WALL TO BE REMOVED

SCALE

EXISTING/ DEMOLITION WEST


ELEVATION
1/4" = 1'-0"

1/4" = 1'-0"

DRAWN BY

CG

CHECKED BY

TM

JOB NO.

FIRST FLOOR
0"

04/27/16

1304

FLOORPLATE / WALL AREA TO BE REMOVED

A0.14

DEMOLITION CALCULATIONS TABLE

DEMOLITION PERCENTAGES:
INTERIOR STRUCTURAL FRAMEWORK & FLOOR
PLATES
FLOOR

TOTAL (E) SQ. FTG.


FLOOR PLATE

DEMOLISHED SQ. FTG.


FLOOR PLATE

PERCENTAGE

1ST

NA

NA

NA

2ND

2645

0%

TOTAL

2645

0%

WALL

TOTAL (E) LINEAR FEET


EXISTING WALL

DEMOLISHED LINEAR FEET


DEMO WALL

PERCENTAGE

1ST

267

233

87

2ND

120

120

100%

TOTAL

387

353

91%

Revisions

COMBINED TOTAL

NOTE: If removal and replacement of additional building elements considered beyond repair is required during
construction, contact the Planning Department immediately for review and approval. This includes floor framing,
sidewalls and other structural members not visible from the public right-of-way. Removal of elements beyond percentages
submitted above is considered a violation. If removal is beyond percentages outlined in Planning Code Section 1005, further
environmental review by the Planning Department is required.

P.L.

DEMOLITION PERCENTAGES: EXTERNAL WALLS

P.L.
EXTERNAL WALLS
TO REMAIN
.

(0% + 91%) / 2 = 45.6%

AREA TO BE DEMOLISHED SHOWN HATCHED:


DEMO AREA: 269 sq ft
TOTAL AREA: 2186 sq ft
DEMO %: 12% = 269 / 2186

FACADE

TOTAL SQ. FTG.

DEMOLISHED SQ. FTG.

PERCENTAGE

NORTH

2052 sq ft

470 sq ft

23%

EAST

973 sq ft

407 sq ft

42%

SOUTH

2186 sq ft

149 sq ft

7%

WEST

832 sq ft

0 sq ft

0%

TOTAL

6043 sq ft

1026 sq ft

17%

645-647
VALENCIA ST.
VARIANCE
APPLICATION:
PREVIOUS APPS
BPA#2015.0305.0103
EE#2015.1339E

3576/ 062

NOTICE
CODE: SFPC SEC 1005.(f)
(f) FOR PURPOSES OF THIS ARTICLE 10, DEMOLITION SHALL BE DEFINED AS ANY ONE OF THE FOLLOWING:

(E) T.O. Parapet


29' - 1 1/2"

(E) Roof
25' - 4"

(1) REMOVAL OF MORE THAN 25% OF THE SURFACE OF ALL EXTERNAL WALLS FACING A PUBLIC
STREET(S); OR
(2) REMOVAL OF MORE THAN 50% OF ALL EXTERNAL WALLS FROM THEIR FUNCTION AS ALL EXTERNAL
WALLS; OR
(3) REMOVAL OF MORE THAN 25% OF EXTERNAL WALLS FROM THEIR FUNCTION AS EITHER EXTERNAL
OR INTERNAL WALLS; OR
(4) REMOVAL OF MORE THAN 75% OF THE BUILDINGS EXISTING INTERNAL STRUCTURAL FRAMEWORK
OR FLOOR PLANS UNLESS THE CITY DETERMINES THAT SUCH REMOVAL IS THE ONLY FEASIBLE
MEANS TO MEET THE STANDARDS FOR SEISMIC LOAD AND FORCES OF THE LATEST ADOPTED
VERSION OF THE SAN FRANCISCO BUILDING CODE AND THE STATE HISTORICAL BUILDING CODE.

268 sq ft

FINDINGS:
SFPC SEC 1005.(f)(1): PERCENTAGE OF EXTERNAL WALLS TO BE REMOVED (17%) FROM THEIR FUNCTION
AS EXTERNAL WALLS IS LESS THAN 50%. PROJECT COMPLIES.
SFPC SEC 1005.(f)(2): PERCENTAGE OF EXTERNAL WALLS TO BE REMOVED (17%) FROM THEIR FUNCTION
AS EXTERNAL WALLS IS LESS THAN 50%. PROJECT COMPLIES.

SECOND FLOOR
12' - 11 1/2"

SFPC SEC 1005.(f)(3): PERCENTAGE OF EXTERNAL WALLS TO BE REMOVED (17%) FROM FUNCTION AS
EXTERNAL OR INTERNAL WALLS IS LESS THAN 25%. PROJECT COMPLIES.

These drawings and


specifications are the property
and copyright of Kerman/Morris
Architects and shall not be used
on any other work except by
written agreement with
Kerman/Morris Architects.
The Contractor shall verify all
existing conditions. Written
dimensions take preference over
scaled dimensions and shall be
verified on the project site. Any
discrepancy shall be brought to
the attention of Kerman Morris
Architects prior to the
commencement of any work.
These drawings are an industry
standards builders set for
building permit and to assist the
contractor in construction. The
drawings show limited and only
representative/typical details.
All attachments, connections,
fastenings,etc, are to be properly
secured in conformance with
best practice, and the Contractor
shall be responsible for providing
and installing them.

SFPC SEC 1005.(f)(4): TOTAL "INTERNAL STRUCTURAL FRAMEWORK OR FLOORPLATES" TO BE REMOVED IS


LESS THAN 75% OF EXISTING. PROJECT COMPLIES.

PARTITION / DEMO LEGEND

(E) SOUTH
ELEVATION

WALL TO REMAIN
DATE

STRUCT. WALL TO BE REMOVED

FIRST FLOOR
0"
NON-STRUCT. WALL TO BE REMOVED

SCALE

04/27/16
1/4" = 1'-0"

DRAWN BY

CG

CHECKED BY

TM

JOB NO.

1304

FLOORPLATE / WALL AREA TO BE REMOVED

EXISTING/ DEMOLITION SOUTH


ELEVATION
1/4" = 1'-0"

A0.15

Revisions

SYCAMORE ST.

1
A3.01

80' - 0" (LOT DEPTH)


(N) 24" BOX SIZE STREET TREE
PER SF STANDARD AND S.143

10' - 0"

645-647
VALENCIA ST.

NEW CURBCUT

(N) OPENING @
BRICK WALL

(E) CORNER ENTRY FOR COMMERCIAL


TO REMAIN PROVIDE (N) STORE FRONT

1
A2.01

5' - 7 1/2"

(E) WINDOW TO REMAIN


IN (E) BRICK WALL

9' - 0 1/2"

10' - 0"

(N) OPENING @BRICK


WALL

(E) WINDOW TO REMAIN

(N) RECESSED BRICK


INFILL @ (E) OPENINGS TO
REMAIN

(N) OPENING @ BRICK WALL

VARIANCE
APPLICATION:
PREVIOUS APPS
BPA#2015.0305.0103
EE#2015.1339E

P.L.
GARAGE
OPENING

GAS CLOSET

3576/ 062

25' - 0"
ELEC.

NOTICE
6' - 3"

TRASH

0'-0"

25' - 7"
35' - 0" (LOT WIDTH)

1
A2.02

0'-0"
8' X8' ADA BATHROOM

COMMERCIAL
HC
BATH

MAIL

8' - 0"

RESIDENTIAL LOBBY

M-OCCUPANCY
517 SQ.FT

VAN ACCESSIBLE PARKING


SPACE 1 (8'-2" MIN.
HEADROOM)

GARAGE

(2-HR EXIT LOBBY R-2


OCCUPANCY)

These drawings and


specifications are the property
and copyright of Kerman/Morris
Architects and shall not be used
on any other work except by
written agreement with
Kerman/Morris Architects.
The Contractor shall verify all
existing conditions. Written
dimensions take preference over
scaled dimensions and shall be
verified on the project site. Any
discrepancy shall be brought to
the attention of Kerman Morris
Architects prior to the
commencement of any work.

18' - 0"

9' - 0"

2
A2.02

20' - 0"

ADJACENT PROPERTY
3756/ 114-116

These drawings are an industry


standards builders set for
building permit and to assist the
contractor in construction. The
drawings show limited and only
representative/typical details.
All attachments, connections,
fastenings,etc, are to be properly
secured in conformance with
best practice, and the Contractor
shall be responsible for providing
and installing them.

U-OCCUPANCY
1171 SQ. FT

8' - 0"

(E) ENTRYWAY TO REMAIN

8' MIN HC DROP OFF

1
A3.02

VALENCIA ST.

7 CLASS 1
BIKE PARKING
SPACES

4 VEHICLE PARKING SPACES

PROVIDE (N) WOOD


WINDOWS
@ HISTORIC BRICK
OPENINGS

16' - 0"

PARKING SPACES 2, 3,
4
(CAR STACKER)

0'-0"

UP

UP
(N) STREET TREE
PER S. 143

ELEVATOR
SHAFT
(2-HR SHAFT)

(E) WALLS TO REMAIN, TYP.

PROPOSED
FIRST FLOOR
PLAN

DATE

04/27/16

7
P.L

SCALE
COMMON STAIR # 1

PROPOSED BLDG @ 657 VALENCIA

1
A2.03

3576/ 061

0'

PROPOSED FIRST FLOOR


1/4" = 1'-0"

1/4" = 1'-0"

COMMON STAIR # 2

1'

2'

4'

DRAWN BY

SN

CHECKED BY

TM

JOB NO.

1304

8'

A1.01

1
A2.01

A3.01

(E) CORNICE TO REMAIN

15' - 0"

P.L.

5' - 0"

1
PRIVATE DECK UNIT#4
49 SF

65' - 0"
2 BR

(N) CORNICE TO MATCH EXISTING

STUDIO

Revisions

BATH 1

MASTER BEDROOM 2
10'-0" X 12'-6"

(E) ORNAMENTAL PARAPET


TO REMAIN

LIVING AND DINING


16'-3" X 16'-6"

BEDROOM 1
10'-0" X 12'-4"
21' - 5"

LIVING/ DINING
12'-6" X 17'-2"

2
A2.02

UNIT-5
2 BEDROOM/ 2 BATH

W/D

A3.02

1
A2.02

875 SQ. FT

PRIVATE DECK
UNIT #5
686 SF

BATH 2

UNIT-4

KITCHEN

STUDIO, 1 BATH
486 SQ. FT

24' - 0 1/2"
REF.

6
KITCHEN
8' X 7'-10"
DN

645-647
VALENCIA ST.

DN

8' - 7"

ELEVATOR
SHAFT
(2-HR SHAFT)

BATHROOM
9'-4" X 7'-7"

VARIANCE
APPLICATION:
PREVIOUS APPS
BPA#2015.0305.0103
EE#2015.1339E

REF.

UP

UP

W/D

7
P.L.

P.L.

COMMON STAIR # 1

COMMON STAIR # 2

PROPOSED BLDG @ 657 VALENCIA

1
A2.03

PROPOSED THIRD FLOOR

0'

1'

2'

4'

8'

1/4" = 1'-0"
3576/ 062

1
A2.01

(E) WINDOW TO REMAIN

(N) WINDOW IN (E) OPENING

A3.01

(N) WINDOW ; TYP.

NOTICE
These drawings and
specifications are the property
and copyright of Kerman/Morris
Architects and shall not be used
on any other work except by
written agreement with
Kerman/Morris Architects.

P.L.

The Contractor shall verify all


existing conditions. Written
dimensions take preference over
scaled dimensions and shall be
verified on the project site. Any
discrepancy shall be brought to
the attention of Kerman Morris
Architects prior to the
commencement of any work.

KITCHEN
BEDROOM 1
11'-2" X 13'-1"

LIVING/ DINING
18'-2 1/2" X 11'-7"

REF.

These drawings are an industry


standards builders set for
building permit and to assist the
contractor in construction. The
drawings show limited and only
representative/typical details.

W/D

BEDROOM 1
11'-0" X 10'-6"

LIVING/ DINING
13'-11 1/2" X 21'-0"

UNIT-2

A3.02

All attachments, connections,


fastenings,etc, are to be properly
secured in conformance with
best practice, and the Contractor
shall be responsible for providing
and installing them.

UNIT-1

1 BEDROOM/ 1 BATH
670 SQ. FT

1 BEDROOM/1 BATH
727 SQ. FT

UNIT-3
1 BEDROOM/ 1 BATH

2
A2.02

701 SQ. FT
BATH

KITCHEN

1
A2.02

BATH

REF.

BATH

W/D

REF.
LIVING/ DINING
12'-9 1/2" X 23'-3"

12' - 11 1/2"

BEDROOM 1
10'-9 1/2" X 12'-2"

PROPOSED
SECOND &
THIRD FLOOR
PLAN

DATE

SCALE
DRAWN BY

DN

DN

1/4" = 1'-0"
CG, SN

KITCHEN

ELEVATOR
SHAFT
(2-HR SHAFT)

CHECKED BY

(E) WINDOWS TO REMAIN; TYP.


UP

W/D

TM
1304

REF.

JOB NO.
UP

04/27/16

REF.

7
P.
L

PROPOSED SECOND FLOOR


1/4" = 1'-0"

COMMON STAIR # 1
PROPOSED BLDG @ 657 VALENCIA

COMMON STAIR # 2

1
A2.03
0'

1'

2'

4'

8'

A1.02

1
A2.01

1
A3.01

15' - 0"

26' - 3 1/2"

5' - 8 1/2"

20' - 0"

1
SUBJECT TO ALLEY REGS S.261.1(d)(2)

5' - 0"

P.
L

13' - 0"

11' - 5 1/2"

SOLID 42" PARAPET/ HANDRAIL; TYP.

5' - 9"

Revisions
3
4
1

8' - 6"

A3.02

1
A2.02

PRIVATE DECK UNIT #7


708 SF
DINING/ LIVING
(13'-0" X 25'-6")

44' - 8 1/2"
4' - 0"

15' - 8"

2
A2.02

UNIT-7

BEDROOM 3
(11'-6" X 10'-0")

3 BEDROOM/ 2 BATH
850 SQ. FT UPPER LEVEL; TOTAL SQ. FT= 1378

DN

15' - 0 1/2"

DN

8' - 7"

ELEVATOR
SHAFT
(2-HR SHAFT)

645-647
VALENCIA ST.

KITCHEN

VARIANCE
APPLICATION:
PREVIOUS APPS
BPA#2015.0305.0103
EE#2015.1339E

W/D

7
COMMON STAIR # 1

PRIVATE STAIR DOWN TO LOWER LEVEL

PROPOSED BLDG @ 657 VALENCIA

1
A2.03

PROPOSED FIFTH FLOOR

0'

1'

2'

4'

8'

1/4" = 1'-0"
3576/ 062

1
A2.01
A

NOTICE

A3.01

P.L.

1
15' - 0"

5' - 0"

P.
L

60' - 0" FROM CORNER


GLASS RAIL

6' - 5 1/2"

20' - 0"

BEDROOM 2
10'-4 " X 13'-7"

SUBJECT TO ALLEY REGS. S.261.1(d)(2)

KITCHEN

PRIVATE DECK UNIT #


7
116 SF

LIVING/ DINING
12'-10 " X 21'-0"

REF.
REF.

21' - 5"

A3.02

2
A2.02

DEN/ BEDROOM 2
10'-0" X 12'-0"

The Contractor shall verify all


existing conditions. Written
dimensions take preference over
scaled dimensions and shall be
verified on the project site. Any
discrepancy shall be brought to
the attention of Kerman Morris
Architects prior to the
commencement of any work.
These drawings are an industry
standards builders set for
building permit and to assist the
contractor in construction. The
drawings show limited and only
representative/typical details.

BEDROOM 1
10'-3 " X 10'-0"

These drawings and


specifications are the property
and copyright of Kerman/Morris
Architects and shall not be used
on any other work except by
written agreement with
Kerman/Morris Architects.

All attachments, connections,


fastenings,etc, are to be properly
secured in conformance with
best practice, and the Contractor
shall be responsible for providing
and installing them.

MASTER ROOM 1
11'-3 " X 13'-6"

1
A2.02

PROPOSED
FOURTH & FIFTH
FLOOR PLAN

BATH

23' - 6 1/2"

W/D

UNIT-6
34' - 4 1/2"

2 BEDROOM/ 2 BATH
909 SQ. FT

UNIT-7

DATE
COMMON STAIR # 2

528 SQ FT
@ LOWER LEVEL

SCALE
DRAWN BY

DN

04/27/16
1/4" = 1'-0"
CG, SN

DN

8' - 7"

ELEVATOR
SHAFT
(2-HR SHAFT)

CHECKED BY
JOB NO.

UP

TM
1304

UP

7
P.
L

PROPOSED FOURTH FLOOR


1/4" = 1'-0"

COMMON STAIR # 1

PRIVATE STAIR UP TO UPPER LEVEL

PROPOSED BLDG @ 657 VALENCIA

1
A2.03
0'

1'

2'

4'

8'

A1.03

Revisions

645-647
VALENCIA ST.
VARIANCE
APPLICATION:
PREVIOUS APPS
BPA#2015.0305.0103
EE#2015.1339E

P.L.
1

2
+24'- 1/2"

3576/ 062
+34'-4 1/2"

NOTICE

PENTHOUSE PRIVATE DECK @ LEVEL 5


PRIVATE DECK @ LEVEL 4

3
4

PRIVATE DECK @ LEVEL 3

These drawings and


specifications are the property
and copyright of Kerman/Morris
Architects and shall not be used
on any other work except by
written agreement with
Kerman/Morris Architects.

1
The Contractor shall verify all
existing conditions. Written
dimensions take preference over
scaled dimensions and shall be
verified on the project site. Any
discrepancy shall be brought to
the attention of Kerman Morris
Architects prior to the
commencement of any work.

35' - 0" (LOT WIDTH)

A3.02

+44'-8 1/4"

+55'-0"

These drawings are an industry


standards builders set for
building permit and to assist the
contractor in construction. The
drawings show limited and only
representative/typical details.
All attachments, connections,
fastenings,etc, are to be properly
secured in conformance with
best practice, and the Contractor
shall be responsible for providing
and installing them.

UNOCCUPIED ROOF

6
+60'-2"

STAIR PENTHOUSE

ELEVATOR
PENTHOUSE

PROPOSED
ROOF PLAN

7
80' - 0" ( LOT DEPTH)
DATE
SCALE
DRAWN BY

04/27/16
1/4" = 1'-0"
CG, SN

CHECKED BY
N

0'

PROPOSED ROOF PLAN


1/4" = 1'-0"

1'

2'

4'

JOB NO.

TM
1304

8'

A1.04

Revisions
20' - 0"
SUBJECT TO S.261.1 (d)(2) SUN ACCESS ANGLE

ELEVATOR TOWER
60' - 2"

ROOF
55' - 0"

GLASS RAILS; TYP

10' - 3 3/4"

VARIANCE
APPLICATION:
PREVIOUS APPS
BPA#2015.0305.0103
EE#2015.1339E

STUCCO FINISH
AT PROPOSED
ADDITION; TYP

(N) ALUMINUM WINDOWS AND


SLIDING GLASS DOORS IN PUNCHED
OPENINGS, TYP.

FOURTH FLOOR
34' - 4 1/2"

(E) ADJACENT PROPERTY:


2 LEXINGTON
4 LEXINGTON
85 SYCAMORE STREET
BLOCK3576/LOTS 114-116
4 STORIES

645-647
VALENCIA ST.

NEW ADDITION

FIFTH FLOOR
44' - 8 1/4"

3576/ 062

NOTICE

10' - 4"

These drawings and


specifications are the property
and copyright of Kerman/Morris
Architects and shall not be used
on any other work except by
written agreement with
Kerman/Morris Architects.

(N) WINDOW ON (E) STUCCO


WALL, TYP.

THIRD FLOOR
24' - 0 1/2"
(E) STUCCO FACADE, PAINT
(N) CONSTRUCTION

EXISTING STRUCTURE

11' - 1"

(E) WINDOW TO REMAIN

SECOND FLOOR
12' - 11 1/2"

The Contractor shall verify all


existing conditions. Written
dimensions take preference over
scaled dimensions and shall be
verified on the project site. Any
discrepancy shall be brought to
the attention of Kerman Morris
Architects prior to the
commencement of any work.
These drawings are an industry
standards builders set for
building permit and to assist the
contractor in construction. The
drawings show limited and only
representative/typical details.
All attachments, connections,
fastenings,etc, are to be properly
secured in conformance with
best practice, and the Contractor
shall be responsible for providing
and installing them.

(E) BRICK FACADE

NORTH
ELEVATION

ADJACENT
PROPERTY
REAR YARD

RETAIL ENTRANCE

(N) GARAGE DOOR

DATE

BLOCK IN AT (E) WINDOW


OPENING

SCALE
DRAWN BY

FIRST FLOOR
0"

04/27/16
1/4" = 1'-0"
CG, SN

CHECKED BY
(N) RESIDENTIAL ENTRY

(N) GAS CLOSET

OPENING BEYOND IN
OBLIQUE ANGLE

JOB NO.

TM
1304

(E) WINDOWS TO REMAIN


(E) OPENING TO REMAIN

NORTH/ SYCAMORE STREET ELEVATION


1/4" = 1'-0"

A2.01

PROPOSED BUILDING
OUTLINE @657
VALENCIA

35' - 0" (LOT WIDTH)


35' - 0" (LOT WIDTH)

ELEVATOR TOWER
60' - 2"

ELEVATOR TOWER
60' - 2"

ROOF
55' - 0"

ROOF
55' - 0"

ALUM. SLIDING GLASS


DOOR; TYP

Revisions

PROPOSED
BLDG @
657 VALENCIA
55' TALL

STUCCO TO MATCH
EXISTING

NEW 4 STORY ADDITION @ REAR/ EAST ELEVATION ONLY

FIFTH FLOOR
44' - 8 1/4"

NEW ADDITION ( 3 STORIES)

STUCCO, TYP

FIFTH FLOOR
44' - 8 1/4"

ALUM. WINDOW W/ GLASS


GUARDRAIL; TYP.

FOURTH FLOOR
34' - 4 1/2"

FOURTH FLOOR
34' - 4 1/2"

VARIANCE
APPLICATION:
PREVIOUS APPS
BPA#2015.0305.0103
EE#2015.1339E

3576/ 062

NOTICE

(N) STEEL PROPERTY LINE WINDOWS


(FIXED)

These drawings and


specifications are the property
and copyright of Kerman/Morris
Architects and shall not be used
on any other work except by
written agreement with
Kerman/Morris Architects.
The Contractor shall verify all
existing conditions. Written
dimensions take preference over
scaled dimensions and shall be
verified on the project site. Any
discrepancy shall be brought to
the attention of Kerman Morris
Architects prior to the
commencement of any work.

THIRD FLOOR
24' - 0 1/2"

THIRD FLOOR
24' - 0 1/2"

These drawings are an industry


standards builders set for
building permit and to assist the
contractor in construction. The
drawings show limited and only
representative/typical details.

EXISTING STUCCO FACADE

(N) WOOD WINDOW @ (E)


WINDOW OPENING; TYP

SECOND FLOOR
12' - 11 1/2"

SECOND FLOOR
12' - 11 1/2"

EXISTING BUILDING

(N) PROPERTY LINE WINDOWS


(FIXED)

RETAIL ENTRANCE (ALUM.


STOREFRONT ENTRY DOOR)

All attachments, connections,


fastenings,etc, are to be properly
secured in conformance with
best practice, and the Contractor
shall be responsible for providing
and installing them.

EAST & WEST


ELEVATIONS

EXISTING BRICK FACADE


(1-STORY) TO REMAIN

EXISTING REAR ELEVATION

645-647
VALENCIA ST.

RESIDENTIAL EGRESS
(PTD STL DOOR)

DATE
SCALE
DRAWN BY

FIRST FLOOR
0"

FIRST FLOOR
0"

EAST ELEVATION
1/4" = 1'-0"

WEST/ VALENCIA FACADE ELEVATION


1/4" = 1'-0"

1/4" = 1'-0"
CG, SN

CHECKED BY
(N) WINDOWS IN
HISTORIC OPENINGS

04/27/16

JOB NO.

TM
1304

A2.02

80' - 0" (LOT DEPTH)

Revisions

ELEVATOR TOWER
60' - 2"

ROOF
55' - 0"
OUTLINE OF PROPOSED BUILDING
AS EXPANDED @ SUBJECT LOT

OUTLINE OF PROPOSED ADJACENT


BUILDING @
657 VALENCIA ST (3576/061)
IN REVIEW AT PLANNING (BPA #
2015.1023.0632)

645-647
VALENCIA ST.

FIFTH FLOOR
44' - 8 1/4"

VARIANCE
APPLICATION:
PREVIOUS APPS
BPA#2015.0305.0103
EE#2015.1339E
BLIND WALL AGAINST
PROPOSED NEW
STRUCTURE @ 657
VALENCIA
3576/ 062

FOURTH FLOOR
34' - 4 1/2"

NOTICE
These drawings and
specifications are the property
and copyright of Kerman/Morris
Architects and shall not be used
on any other work except by
written agreement with
Kerman/Morris Architects.
The Contractor shall verify all
existing conditions. Written
dimensions take preference over
scaled dimensions and shall be
verified on the project site. Any
discrepancy shall be brought to
the attention of Kerman Morris
Architects prior to the
commencement of any work.

THIRD FLOOR
24' - 0 1/2"

These drawings are an industry


standards builders set for
building permit and to assist the
contractor in construction. The
drawings show limited and only
representative/typical details.
All attachments, connections,
fastenings,etc, are to be properly
secured in conformance with
best practice, and the Contractor
shall be responsible for providing
and installing them.

SECOND FLOOR
12' - 11 1/2"

SOUTH
ELEVATION

OUTLINE OF EXISTING
ADJACENT BUILDING @ 657
VALENCIA ST (3576/061)
PARAPET HT. +/- 19'-3"

ADJACENT
PROPERTY REAR
YARD

DATE
SCALE
DRAWN BY

VALENCIA
STREET

FIRST FLOOR
0"

SOUTH ELEVATION
1/4" = 1'-0"

1/4" = 1'-0"
CG, SN

CHECKED BY
JOB NO.

04/27/16

TM
1304

A2.03

P.L.

Revisions

ELEVATOR TOWER
60' - 2"
PROPOSED BUILDING
OUTLINE @ 657
VALENCIA

ROOF
55' - 0"

UNIT 7
GLASS RAIL

645-647
VALENCIA ST.

SIGHT LINE AT MID OF THE BUILDING .


NOTE: 4TH FLOOR PARAPET OBSCURES FIFTH FLOOR FROM VIEW

VARIANCE
APPLICATION:
PREVIOUS APPS
BPA#2015.0305.0103
EE#2015.1339E

(STUCCO)

ADDITION:

NEW CONSTRUCTION TYPE III

FIFTH FLOOR
44' - 8 1/4"

UNIT 7

GLASS RAIL
ADDITIONAL ALLEY HEIGHT LIMIT FOR PORTION OF
BUIDING GREATER THAN 60 FEET FROM VALENCIA STREET
PER SECTION 261.1(d)(2)

FOURTH FLOOR
34' - 4 1/2"

3576/ 062

NOTICE
These drawings and
specifications are the property
and copyright of Kerman/Morris
Architects and shall not be used
on any other work except by
written agreement with
Kerman/Morris Architects.

(E) PARAPET AND CORNICE TO REMAIN

UNIT 4

The Contractor shall verify all


existing conditions. Written
dimensions take preference over
scaled dimensions and shall be
verified on the project site. Any
discrepancy shall be brought to
the attention of Kerman Morris
Architects prior to the
commencement of any work.

(E) SYCAMORE 2 STORY FACADE TO REMAIN

THIRD FLOOR
24' - 0 1/2"

STUCO

These drawings are an industry


standards builders set for
building permit and to assist the
contractor in construction. The
drawings show limited and only
representative/typical details.

EXISTING
STRUCTURE @ 657
VALENCIA

All attachments, connections,


fastenings,etc, are to be properly
secured in conformance with
best practice, and the Contractor
shall be responsible for providing
and installing them.

SECOND FLOOR
12' - 11 1/2"

EAST (REAR)
SECTION

(E) 2ND FLOOR TO REMAIN

GARAGE

BRICK

EXISTING TO REMAIN

UNIT 1

DATE

45.0
0

SCALE

FIRST FLOOR
0"

DRAWN BY

04/27/16
1/4" = 1'-0"
CG, SN

CHECKED BY
JOB NO.

TM
1304

SYCAMORE (35')

N-S SECTION @ REAR


1/4" = 1'-0"

A3.01

Revisions

80' - 0" (LOT DEPTH)

ELEVATOR TOWER
60' - 2"

ROOF
55' - 0"

UNIT 7
PRIVATE DECK
UNIT 7

645-647
VALENCIA ST.

(E) ADJACENT PROPERTY:


2 LEXINGTON
4 LEXINGTON
85 SYCAMORE STREET
BLOCK3576/LOTS 114-116
4 STORIES

UNIT 7

30' - 11 1/2" NEW ADDITION

FIFTH FLOOR
44' - 8 1/4"

UNIT 6

VARIANCE
APPLICATION:
PREVIOUS APPS
BPA#2015.0305.0103
EE#2015.1339E

3576/ 062

FOURTH FLOOR
34' - 4 1/2"

NOTICE
These drawings and
specifications are the property
and copyright of Kerman/Morris
Architects and shall not be used
on any other work except by
written agreement with
Kerman/Morris Architects.

UNIT 5
PRIVATE DECK

UNIT 4

The Contractor shall verify all


existing conditions. Written
dimensions take preference over
scaled dimensions and shall be
verified on the project site. Any
discrepancy shall be brought to
the attention of Kerman Morris
Architects prior to the
commencement of any work.

UNIT 5

THIRD FLOOR
24' - 0 1/2"

These drawings are an industry


standards builders set for
building permit and to assist the
contractor in construction. The
drawings show limited and only
representative/typical details.

UNIT 1

UNIT 2

All attachments, connections,


fastenings,etc, are to be properly
secured in conformance with
best practice, and the Contractor
shall be responsible for providing
and installing them.

UNIT 3

24' - 0 1/2"

SECOND FLOOR
12' - 11 1/2"

ADJACENT
PROPERTY REAR
YARD
GARAGE

RESIDENTIAL
LOBBY

BIKES

COMMERCIAL

EXISTING
BUILDING

BUILDING
SECTION

DATE
SCALE
DRAWN BY

FIRST FLOOR
0"

LONGITUDINAL BUILDING SECTION


1/4" = 1'-0"

1/4" = 1'-0"
CG, SN

CHECKED BY
JOB NO.

04/27/16

TM
1304

A3.02

Anda mungkin juga menyukai