Anda di halaman 1dari 30

277

Compact Photoelectric Sensor

Amplifier Built-in

CX-400 SERIES Ver.2

FIBER
SENSORS

Related Information

LASER
SENSORS

General terms and conditions.............. F-7

Sensor selection guide................... P.271~

MS-AJ / CHX-SC2...............P.979 / P.980

Glossary of terms / General precautions......P.1455~ / P.1458~

Koreas S-mark.............................. P.1506

PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS

Conforming to
EMC Directive

Recognition

AREA
SENSORS
Certified
(Some models only)

LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS

panasonic.net/id/pidsx/global

STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS

PNP output
type available

Light intensity
monitor

Interference
prevention

Sensors that are environmentally and user friendly.


Reducing environmental burdens further
Up to 60% less power consumption
The various lineup covers through the inclusion of a newly developed
custom integrated circuit.The CX-400 series achieves reductions in
power consumption of up to 60%, averaging 44% reduction when
upgrading due to its unique design. These sensors reduce carbon
emissions and contribute to environmental friendliness.
Providing stable detection with low power
consumption

Includes an analog CMOS


processor ASIC
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

Upgrade for up to

60

CX-400
CY-100

% reduction

EX-10

Strong against oil and coolant liquids CX-41/42/49


The lens material for
the thru-beam type,
retroreflective type
(excluding the CX-48)
and the diffuse reflective
type are made of a strong
acrylic that resists the
harmful effects of coolants.
These sensors can be
used with confidence even
around metal processing
machinery that disperses oil
mists. The protection mechanism also conforms to IP67
(IEC).
Test Oil

JIS Standard

Product Name

Lubricant

Velocity Oil No. 3

Water-insoluble
cutting oil

2-5

Daphnecut AS-30D

2-11

Yushiron Oil No.2ac (Note)

W1-1

Yushiron Lubic HWC68 (Note)

W2-1

Yushiroken S50N (Note)

Water-soluble
cutting oil

1,000 hours; Immersion (depth 0 m); Insulation resistance 20 M/250 V


Note: Yushiron and Yushiroken are registered trademarks of
Yushiro Chemical Industry Co., Ltd.

EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

Previous CX-482
25 mA

Strong against ethanol

New CX-482
10 mA

Contributing to reduced carbon dioxide emissions


Electricity consumed by the CX-400
series has been reduced on average
10.5 mA. Calculating 8 hours/day, 260
days (operating 5 days/week) for a total
of 2,080 hours/year leads to:

The CX-400
contributes

Approx. 84.6 t annually in carbon


dioxide reductions to the world

CX-44/48

A strong, ethanol resistant


polycarbonate was used for the
front and display covers.
Safe even for installing near
food processing machinery that
disperses ethanol based detergents.
The protection mechanism also
conforms to IP67 (IEC).
Caution: Set the CX-48 so that cleaning liquid will not get on to the
attached reflector.

Compact Photoelectric Sensor

278

CX-400 SERIES Ver.2

APPLICATIONS

FIBER
SENSORS

Detecting out of position tape


feeder cassette

Detecting objects in dusty


environment

Passage confirmation of object


on a conveyor belt

LASER
SENSORS
PHOTOELECTRIC
SENSORS

CX-412

MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS

Slit mask
CX-491
Out of position
CX-411

Detecting transparent glass bottles

Detecting a small tablet

Detecting a biscuit

LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS

CX-441

CX-443

SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES

CX-481

LASER
MARKERS
PLC

BASIC PERFORMANCE

Strong infrared beam

CX-412/413

Remarkable penetrating power enables applications


such as package content detection.

Can sense differences as small as 0.4 mm 0.016 in,


CX-441/443
with hysteresis of 2 % or less
An advanced optical system provides sensing
performance that is 2.5 times approx. than conventional
models. Even ultra-small differences of 0.4 mm 0.016 in
can be detected accurately.

HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS

2.5 times the


sensing capability!

Note: When sensing utilizing penetrating power, make sure to verify


using the actual sensor.

Hardly affected by colors

CX-441/443

Both black and white objects can be sensed at the


same distances. No adjuster control is needed, even
when products of different colors are moving along the
production line.

Height differences of as
little as 0.4 mm 0.016 in
can be detected at a
setting distance of 20 mm
0.787 in

Retroreflective type with polarizing filters CX-491


Built-in polarizing filters ensure stable sensing even on a
specular object.

Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

CX-400
CY-100
EX-10
EX-20
EX-30

30 % higher
sensing capability

EX-40
CX-440
EQ-30
EQ-500

CX-491

The difference in sensing ranges is 1% or less between non-glossy white paper with a
setting distance of 50 mm 1.969 in and non-glossy gray paper with a brightness level of 5.

MQ-W
RX-LS200
RX
RT-610

279

Compact Photoelectric Sensor

FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS

CX-400 SERIES Ver.2

BASIC PERFORMANCE
Our unique optical system and transparent object
sensing circuitry provide stable sensing of even thinner
transparent objects than the conventional models.

AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS

Twice the
sensing range!

PARTICULAR
USE SENSORS

CX-482

SIMPLE
WIRE-SAVING
UNITS

MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES

Long sensing range of 5 m 16.4 ft

Transparent objects detectable with CX-48 (Typical examples)


Sensing object

Sensing object size (mm in)

Glass sheet

50 50 1.969 1.969 t = 0.7 0.028

Cylindrical glass

50 1.969 = 50 1.969 t = 1.3 0.051

Acrylic board

50 50 1.969 1.969 t = 1.0 0.039

Styrol (Floppy case)

50 50 1.969 1.969 t = 0.9 0.035

Food wrapping film

50 50 1.969 1.969 t = 10 m 0.394 mil

Cigarette case film

50 50 1.969 1.969 t = 20 m 0.787 mil

Vinyl sack

50 50 1.969 1.969 t = 30 m 1.181 mil

PET bottle (500m)

66 2.598

Reflector setting range CX-481: 300 to 500 mm 11.811 to 19.685 in,


CX-482: 1 to 2 m 3.281 to 6.562 ft
[with the RF-230 reflector at the optimum condition (Note)]
Each object should pass across the beam at the center between
the sensor and the reflector.
: Length of cylindrical glasses
t: Thickness of sensing object
Note: The optimum condition is defined as the condition in which the
sensitivity level is set such that the stability indicator just lights
up when the object is absent.

SENSOR
OPTIONS

WIRE-SAVING
SYSTEMS

CX-48

Introducing the transparent object sensing type sensor

CX-493

Ultra-long sensing range of 30 m 98.4 ft CX-413


The CX-413 achieves the
ultra-long sensing range
of 30 m 98.4 ft. It can be
used for a stacker crane
or a multilevel parking
structure.

A long 5 m 16.4 ft


sensing range is
possible with the red
LED type that is easy
to align with the beam
axis. Can be used for
wide automatic door
shutters.

ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS

Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

ENVIRONMENTAL RESISTANCE

Strong on dust and dirt

CX-412/413

Because the
light source is an
infrared light, it is
strong on dust and
dirt compared to
the red beam type.

Strong even in cold environments

Stronger noise resistance


The CX-400 series has
a higher noise resistance
than its previons model. By
incorporating an inverter
countermeasure circuit that
appropriately shifts with peak
wavelength, the sensor now
resists high-frequency noise
from high-voltage inverter
motors and
inverter lights more effectively.

Fluorescent
light

Stable performance can be maintained even in


environments of 25 C 13 F.

ECO

Thoroughly eliminating unnecessary waste, Reducing many environmental burdens


The CX-400 series has three different cable length
types and uses very simple packaging to reduce
waste. The bag is made of polyethylene and does not
emit toxic gasses.

Inverter motor

Compact Photoelectric Sensor

MOUNTING

Beam axis alignment made easy with a high luminance spot beam CX-423

The bright spot makes beam axis alignment easy CX-44

These sensors have a


high luminance red LED
spot beam which provides
bright visibility enabling
the sensing position to be
checked at a glance.
Because it achieved small
beam spot approx. 2 mm
0.079 in at setting distance
100 mm 3.937 in, approx.
5 mm 0.197 in at setting
distance 200 mm 7.874 in,
even the minutest object
can be accurately detected.

These sensors have


a high luminance red
spot that provides
bright visibility. The
sensing position can be
checked at a glance.
Because the CX-441
sensor has the smallest
spot in its class 2 mm
0.079 in approx., even
the minutest object can
be accurately detected.

CX-423

Great visibility approx. 2 mm


0.079 in high luminance spot beam
(at setting distance 100 mm 3.937 in)

280

CX-400 SERIES Ver.2

FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS

Great visibility
approx. 2 mm
0.079 in high
luminance spot
CX-441

LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS

OPERABILITY

Reduction of volume adjustment labor CX-42

Can be used for sensing minute differences CX-44

Because these sensors possess many variations


depending on the sensing range, enables you to make
optimal volume adjustment easily.

Equipped with a 5-turn adjuster so that even challenging


range settings can be handled with ease.

SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES

CX-422: 800 mm 31.496 in


CX-421: 300 mm 11.811 in
CX-424: 100 mm 3.937 in

LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES

Narrow-view type

ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS

CX-423: 70 to 300 mm
2.756 to 11.811 in

FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS

VARIETIES

Basic type available

Select from 2 spot diameters as per the application CX-441/443

Omit the sensitivity adjuster and operation mode switch and


release a basic type cable 0.5 m 1.641 ft in length. If the
usage is clear, quick construction can be performed onsite
without detailed adjustments and the cost can be controlled.

Within the choice of 50 mm 1.969 in sensing range sensors,


we offer small spot approx. 2 mm 0.079 in type optimal
for detecting minute object and large approx. 6.5 mm
0.256 in spot type capable of sensing object covered with
holes and grooves.

Less processing time


M8 plug-in connector type and M12 pigtailed type are
available. This contributes to less time spent in setting
up. In addition, cable types are available with cable
lengths of 0.5 m 1.640 ft, 2 m 6.562 ft and 5 m 16.404 ft.
This results in less wastage.

CX-400
CY-100
EX-10
EX-20

No unnecessary cables or terminal blocks


CX-441

Cable type
5 m 16.404 ft

Great maintainability
2 m 6.562 ft

M8 plug-in
connector
type

ft /
( 25 mm 6.562
16.404 ft )
ft /
( 25 mm 6.562
16.404 ft )

Elbow

Straight
0.5 m
1.640 ft

M12 pigtailed
type

Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

Straight

ft /
( 25 mm 6.562
16.404 ft )

Spot diameter: 2 mm
0.079 in
approx.
[Positioning]
Detects minute holes.

CX-443

Spot diameter: 6.5 mm


0.256 in
approx.
Detection of presence /
absence of objects
Ignores minute holes and
accurately detects objects.

EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

281

Compact Photoelectric Sensor

FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS

CX-400 SERIES Ver.2

FUNCTIONS
CX-44

BGS / FGS functions make even the most challenging settings possible!

For details on the operation of the BGS / FGS functions, refer to BGS / FGS functions (p.299) of PRECAUTIONS
FOR PROPER USE.

The BGS function is best suited for the following case

The FGS function is best suited for the following case

Background not present


When object and background are separated

Background present
When object and background are close together
When the object is glossy or uneven

BGS

FGS

Unaffected by gloss, color or


uneven surfaces when sensing
objects present on a conveyor belt.

Not affected if the background


color changes or someone
passes behind the conveyor.

PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS

Caution: Please use the FGS function together with a conveyor or other
background unit.

The sensor judges that an object is present when light


is received at position A of the light-receiving element
(2-segment element).
This is useful if the object and background are far
apart. The distance adjustment method is the same as
the conventional adjustment method for adjustable
range reflective type sensors.

MACHINE VISION
SYSTEMS

OFF

Background

UV CURING
SYSTEMS

Light received at
element B, or
light not received

ON

Element A

Object

EX-20
EX-30
EX-40
CX-440
EQ-30
MQ-W
RX
RT-610

OFF

Object present

For glossy object

ON

ON

Emitting
element

Setting
distance

Conveyor

Light received
at position B
A conveyor or
other
back-ground
must be present

Strong against interference


The interference prevention function lets two sensors to
be mounted close together precisely.
Interference
prevention
filter (Optional)

Retroreflective type
Diffuse reflective type
Adjustable range reflective type

EQ-500
RX-LS200

Object absent

ON in all other conditions

Lens

CX-400
EX-10

OFF in this condition only

(Light received at element A)

Element B
Moving object
in the back

The sensor judges that an object is present when no


light is received at position B of the light-receiving
element (2- segment element). Accordingly, even
objects that are glossy can be sensed. This is useful if
the object and background are close together, or if the
object being sensed is glossy.

Setting distance

Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

CY-100

FGS (Foreground suppression) function

BGS (Background suppression) function

Thru-beam type

Only CX-411

Automatic
interference
prevention function

Conveyor

Light received
at position A

Conveyor

Light is not
received at
position B, so a
object is judged
to be present

Compact Photoelectric Sensor

CX-400 SERIES Ver.2

ORDER GUIDE

FIBER
SENSORS
LASER
SENSORS

Standard type
Type

Appearance

Model No. (Note 1)

Sensing range

CX-411-P

CX-412

CX-412-P

CX-413

CX-413-P

CX-491

CX-491-P

CX-493

CX-493-P

50 to 500 mm 1.969 to 19.685 in (Note 2)

CX-481

CX-481-P

50 to 1,000mm 1.969 to 39.37 in (Note 2)

CX-483

CX-483-P

0.1 to 2 m 0.328 to 6.562 ft (Note 2)

CX-482

CX-482-P

MEASUREMENT
SENSORS

CX-424

CX-424-P

STATIC
ELECTRICITY
PREVENTION
DEVICES

CX-421

CX-421-P

CX-422

CX-422-P

CX-423

CX-423-P

CX-441

CX-441-P

CX-443

CX-443-P

CX-444

CX-444-P

CX-442

CX-442-P

Thru-beam

Long sensing
range

30 m 98.425 ft

Long sensing With polarizing


range
filters

PHOTOELECTRIC
SENSORS

CX-411

15 m 49.213 ft

3 m 9.843 ft (Note 2)

Red LED

300 mm 11.811 in

MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS

Infrared
LED

LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS

Red LED
5 m 16.404 ft (Note 2)

For transparent
object sensing

Retroreflective

Emitting
element

PNP output

100 mm 3.937 in

PARTICULAR
USE
SENSORS
SENSOR
OPTIONS

Switchable
either Light-ON
or Dark-ON

Infrared
LED

Infrared
LED

SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS

LASER
MARKERS
PLC

800 mm 31.496 in
Small Narrowspot view

Diffuse reflective

Output
operation

NPN output

10 m 32.808 ft

Adjustable range reflective

282

70 to 300 mm 2.756 to 11.811 in

HUMAN
MACHINE
INTERFACES

Red LED

FA
COMPONENTS

2 to 50 mm 0.079 to 1.969 in

15 to 100 mm 0.591 to 3.937 in


20 to 300 mm 0.787 to 11.811 in

Switchable either
Detection-ON or
Detection-OFF

MACHINE
VISION
SYSTEMS

Red LED

NOTE: Mounting bracket is not supplied with the sensor. Please select from the range of optional sensor mounting brackets.
Notes: 1) The model No. with E shown on the label affixed to the thru-beam type sensor is the emitter, D shown on the label is the receiver.
2) The sensing range of the retroreflective type sensor is specified for the RF-230 (optional) reflector. The sensing range represents the actual sensing
range of the sensor. The sensing ranges itemized in A of the table below may vary depending on the shape of sensing object. Be sure to check the
operation with the actual sensing object.
Sensing
range: A

Sensor

CX-491

CX-493

CX-481

CX-483

UV
CURING
SYSTEMS

Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

CX-482

50 to 500 mm
50 to 1,000 mm 0.1 to 2 m
1.969 to 19.685 in 1.969 to 39.37 in 0.328 to 6.562 ft

Sensing
object

0 to 3 m
0 to 9.843 ft

Setting range
of the reflector: B

0.1 to 3 m
0.1 to 5 m
100 to 500 mm 100 to 1,000 mm 0.8 to 2 m
0.328 to 9.843 ft 0.328 to 16.404 ft 3.937 to 19.685 in 3.937 to 39.37 in 2.625 to 6.562 ft

Reflector

0 to 5 m
0 to 16.404 ft

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

283

Compact Photoelectric Sensor

ORDER GUIDE

FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS

CX-400 SERIES Ver.2

Basic type (Without operation mode switch and sensitivity adjuster. Cable is 0.5 m 0.02 in long.)
Type

Appearance

Sensing range

MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS

PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES

Thru-beam
Retroreflective

INDUCTIVE
PROXIMITY
SENSORS

Long sensing
range

PRESSURE /
FLOW
SENSORS

15 m 49.213 ft

3 m 9.843 ft (Note 3)

FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS

Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

CX-411A-C05

CX-411A-P-C05

Light-ON

CX-411B-C05

CX-411B-P-C05

Dark-ON

CX-412A-C05

CX-412A-P-C05

Light-ON

CX-412B-C05

CX-412B-P-C05

Dark-ON

CX-491A-C05-Y CX-491A-P-C05-Y

Light-ON

CX-491B-C05-Y CX-491B-P-C05-Y

Dark-ON

Optional (Note 2)

Emitting
element

Red LED

Infrared
LED

Red LED

NOTE: Mounting bracket is not supplied with the sensor. Please select from the range of optional sensor mounting brackets.

Sensing
range: A

PLC

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

Output
operation

Notes: 1) The model No. with E shown on the label affixed to the thru-beam type sensor is the emitter, D shown on the label is the receiver.

2) The reflector is an option. The sensing range of the leflector is specified for the RF-230.
3) The sensing range of the retroreflective type sensor is specified for the RF-230 (optional) reflector (p.285). The sensing range represents the actual
sensing range of the sensor. The sensing range : A of the table below may vary depending on the shape of sensing object. Be sure to check the
operation with the actual sensing object.

LASER
MARKERS

HUMAN
MACHINE
INTERFACES

PNP output

10 m 32.808 ft

With polarizing
filters

LIGHT
CURTAINS /
SAFETY
COMPONENTS

Model No.(Note 1)
NPN output

Sensor

CX-491
Sensing
object

0 to 3 m
0 to 9.843 ft

Setting range
of the reflector: B

0.1 to 3 m
0.328 to 9.843 ft

Reflector
(Optional)

Compact Photoelectric Sensor

CX-400 SERIES Ver.2

ORDER GUIDE

284
FIBER
SENSORS
LASER
SENSORS

0.5 m 1.640 ft / 5 m 16.404 ft cable length types


0.5 m 1.640 ft / 5 m 16.404 ft cable length types (standard: 2 m 6.562 ft, basic: 0.5 m 1.640 ft) are also available.
When ordering this type, suffix -C05 for the 0.5 m 1.640 ft cable length type, -C5 for the 5 m 16.404 ft cable length type to the model No.
(Excluding CX-44 and basic type)
(e.g.) 0.5 m 1.640 ft cable length type of CX-411-P is CX-411-P-C05
5 m 16.404 ft cable length type of CX-411-P is CX-411-P-C5

PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS

M8 plug-in connector type, M12 pigtailed type

PRESSURE /
FLOW
SENSORS

M8 plug-in connector type and M12 pigtailed type are also available.
When ordering this type, suffix -Z for the M8 connector type, -J for the M12 pigtailed type to the model No.
(Please note that M12 pigtailed type is not available for CX-44. Excluding basic type)
(e.g.) M8 connector type of CX-411-P is CX-411-P-Z
M12 pigtailed type of CX-411-P is CX-411-P-J

INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS

Mating cable (2 cables are required for the thru-beam type.)

For M12
pigtailed type

For M8 plug-in
connector type

Type
Straight

Elbow

2-core

4-core

Model No.

Cable length

CN-24A-C2

2 m 6.562 ft

CN-24A-C5

5 m 16.404 ft

CN-24AL-C2

2 m 6.562 ft

CN-24AL-C5

5 m 16.404 ft

CN-22-C2

2 m 6.562 ft

CN-22-C5

5 m 16.404 ft

CN-24-C2

2 m 6.562 ft

CN-24-C5

5 m 16.404 ft

Description

SIMPLE
WIRE-SAVING
UNITS

Mating cable
CN-24A-C2
CN-24A-C5

MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES

Can be used with all models

For thru-beam type emitter


(2-core)

9 mm
0.354 in
31.4 mm
1.236 in

23.1 mm
0.909 in

9 mm
0.354 in

LASER
MARKERS
PLC

20.5 mm
0.807 in
4 mm
0.157 in

Can be used with all models

HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

4 mm
0.157 in

Package without reflector


NPN output type: CX-491-Y
PNP output type: CX-491-P-Y

WIRE-SAVING
SYSTEMS

CN-24AL-C2
CN-24AL-C5

FA
COMPONENTS

CN-22-C2, CN-22-C5
CN-24-C2, CN-24-C5
14 mm
0.551 in

Accessory

MACHINE
VISION
SYSTEMS

5 mm
0.197 in

UV
CURING
SYSTEMS

RF-230 (Reflector)
300 mm
11.811 in

Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

285
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS

Compact Photoelectric Sensor

OPTIONS
Model No.

Designation

Slit mask

LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS

OS-CX-05

()
For thrubeam type
sensor only

WIRE-SAVING
SYSTEMS

CX-411
OS-CX-1

CX-411

CX-411
OS-CX-056
Rectangular slit
mask
For thrubeam type
sensor only

()

CX-413
OS-CX-16

CX-411

PLC

Interference
prevention filter
For CX-411
only

Model No.

()

FA
COMPONENTS

(Vertical, Silver) 2 pcs. per set

PF-CX4-H

Amplifier
Built-in

Amplifierseparated

Reflector

()
For retroreflective type
sensor only

RF-230(Note 3)

CX-440

Sensor

RX
RT-610

Setting range
of the reflector: B

Model No.

26 mm
0.0790.236 in

20 mm 0.787 in

600 mm 23.622 in

30 mm 1.181 in

Slit on one side

Slit on both sides

12 mm 0.472 in

0.5 mm 0.020 in

1,200 mm 47.242 in 60 mm 2.362 in


900 mm 35.433 in

100 mm 3.937 in

1.35 m 4.429 ft

150 mm 5.906 in

2.7 m 8.857 ft

300 mm 11.811 in

2 m 6.562 ft

400 mm 15.748 in

3 m 9.843 ft

600 mm 23.622 in

6 m 19.685 ft

1,200 mm 47.242 in

2 m 6.562 ft

400 mm 15.748 in

3 m 9.843 ft

600 mm 23.622 in

6 m 19.685 ft

1,200 mm 47.242 in

3 m 9.843 ft

1 m 3.281 ft

4.5 m 14.764 ft

1.5 m 4.921 ft

9 m 29.528 ft

3 m 9.843 ft

5 m 16.404 ft

2 m 6.562 ft

7.5 m 24.606 ft

3 m 9.843 ft

15 m 49.213 ft

6 m 19.685 ft

Sensing range

Min. sensing object

12 mm 0.472 in
(Note 1)

5 m 16.404 ft (Note 1)

CX-491

1 m 3.281 ft (Note 2)

CX-493

1.5 m 4.921 ft (Note 2)

1 mm 0.039 in
12 mm 0.472 in

1.5 mm 0.059 in
2 mm 0.079 in

12 mm 0.472 in

3 mm 0.118 in

12 mm 0.472 in

0.5 6 mm
0.020 0.236 in

12 mm 0.472 in

1 6 mm
0.039 0.236 in

12 mm 0.472 in

2 6 mm
0.079 0.236 in

Round slit mask

Round slit mask


(Stainless steel)

OS-CX-
Fitted on the front face
of the sensor with onetouch.

Rectangular slit mask

CX-481

OS-CX-6
Fitted on the front face
of the sensor with onetouch.

30 mm 1.181 in

CX-483

0.1 to 0.3 m 0.328 to 0.984 ft (Note 2)

CX-482

0.1 to 0.6 m 0.328 to 1.969 ft (Note 2)

CX-491

1.5 m 4.921 ft (Note 2)

CX-493

3 m 9.843 ft (Note 2)

CX-481

50 to 300 mm 1.969 to 11.811 in (Note 2)

CX-483

0.1 to 0.7 m 0.328 to 2.297 ft (Note 2)

CX-482

0.1 to 1.3 m 0.328 to 4.265 ft (Note 2)

CX-491-Y

3 m 9.843 ft (Note 2)

35 mm 1.378 in

Interference
prevention filter

Rectangular slit mask


(Stainless steel)

Interference prevention filter

PF-CX4-V
(Vertical, Silver)
PF-CX4-H
(Horizontal, Light brown)
Two sets of CX-411
can be mounted close
together.

50 mm 1.969 in

Reflector
RF-210
Reflector

Reflector

CX-481

RF-220

50 to 300 mm 1.969 to 11.811 in 100 to 300 mm 3.937 to 11.811 in

RF-220

0.1 to 0.7 m 0.328 to 2.297 ft 0.2 to 0.7 m 0.656 to 2.297 ft

RF-210

0.1 to 0.3 m 0.328 to 0.984 ft 0.1 to 0.3 m 0.328 to 0.984 ft

RF-230

0.05 to 1 m 0.164 to 3.281 ft 0.1 to 1 m 0.328 to 3.281 ft

RF-220

0.1 to 1.3 m 0.328 to 4.265 ft 0.5 to 1.3 m 1.640 to 4.265 ft

RF-210

0.1 to 0.6 m 0.328 to 1.969 ft 0.3 to 0.6 m 0.984 to 1.969 ft

CX-483

MQ-W
RX-LS200

16 mm
0.0390.236 in

Sensor

EQ-30
EQ-500

0.56 mm
0.0200.236 in

Sensing
object

EX-10

EX-40

2 mm
0.079 in

Slit on both sides

400 mm 15.748 in

Sensing
range: A

CY-100

EX-30

1 mm
0.039 in

Slit on one side

Min. sensing object

Notes: 1) Value when attached on both sides.


2) Set the distance between the CX-491/493 and the reflector to 0.1 m 0.328 ft or more.
However, see the table below for CX-48.
The sensing range A may vary depending on the shape of sensing object.
Be sure to check the operation with the actual sensing object.

CX-400

EX-20

0.5 mm
0.020 in

Sensing range

(Horizontal, Light brown) 2 pcs. per set

RF-210

Selection
Guide

Slit size

PF-CX4-V

RF-220

Power Supply
Built-in

CX-412
CX-413

Designation

UV
CURING
SYSTEMS

CX-412
CX-413

OS-CX-26

LASER
MARKERS

MACHINE
VISION
SYSTEMS

CX-412
CX-411

STATIC
ELECTRICITY
PREVENTION
DEVICES

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

CX-412
CX-413

MEASUREMENT
SENSORS

HUMAN
MACHINE
INTERFACES

CX-412
CX-413

OS-CX-2

PARTICULAR
USE
SENSORS

SIMPLE
WIRE-SAVING
UNITS

CX-412
CX-413

Round slit mask

INDUCTIVE
PROXIMITY
SENSORS

SENSOR
OPTIONS

Sensor
CX-411

MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS

CX-400 SERIES Ver.2

CX-482

12.8 mm
0.504 in

33.3 mm
1.311 in

3)
RF-230 is attached to the retroreflective type sensor other than the basic type.

11 mm
0.433 in

RF-220
35.3 mm
1.390 in

8.3 mm
0.327 in

RF-230
50.3 mm
1.98 in

42.3 mm
1.665 in
59.3 mm
2.235 in

8.3 mm
0.327 in

Compact Photoelectric Sensor

286

CX-400 SERIES Ver.2

OPTIONS
Designation

FIBER
SENSORS

Model No.
MS-RF21-1

Reflector
mounting
bracket

Sensing range (Note 4):

0.7 m 2.297 ft [CX-491]


1.2 m 3.937 ft [CX-493]
0.1 to 0.6 m
0.328 to 1.969 ft [CX-482]

RF-12

Sensing range (Note 5):

RF-13

0.5 m 1.640 ft [CX-491]

AREA
SENSORS

Ambient temperature: 25 to +50 C

13 to +122 F

Ambient humidity: 35 to 85 % RH

Notes: 1) K
 eep the tape free from
stress. If it is pressed too
much, its capability may
deteriorate.

2) Do not cut the tape. It will
deteriorate the sensing
performance.
Ambient temperature: 25 to +55 C
13 to +131 F
Ambient humidity: 35 to 85 % RH

Foot angled mounting bracket


It can also be used for mounting RF-210.

MS-CX2-1

Sensor checker
(Note 3)

MS-CX2-4
MS-CX2-5

Back biangled mounting bracket

MS-CX-3

Back angled mounting bracket

MS-AJ1

Horizontal mounting type

MS-AJ2

Vertical mounting type

MS-AJ1-A

Horizontal mounting type

MS-AJ2-A

Vertical mounting type

MS-AJ1-M

Horizontal mounting type

MS-AJ2-M

Vertical mounting type

CHX-SC2

It is useful for beam alignment of thru-beam type sensors. The optimum


receiver position is given by indicators, as well as an audio signal.

Basic assembly

45

Assembly for reflector

MS-AJ1-A

45
Elevation
angle: 45

Height
adjustment:
150 mm
5.906 in
approx.
Mounting hole
for M6 screw

Swivel:
360 rotation
45
45
Elevation
angle: 45

With the lateral arm, the


sensor can sense from
above a production line.

Height
adjustment:
150 mm
5.906 in
approx.
Mounting hole
for M6 screw

Swivel:
360 rotation

Forward / back
adjustment:
130 mm 5.118 in
approx.

Height
adjustment:
150 mm
5.906 in
approx.

45
Elevation
angle: 45

360
rotation

45
45
Angle adjustment: 45

With the lateral arm, the


sensor can sense from
above a production line.
Forward / back
adjustment:
130 mm 5.118 in
approx.

360
rotation

SENSOR
OPTIONS

Reflective tape
30 mm
1.181 in

SIMPLE
WIRE-SAVING
UNITS

RF-12
0.7 mm
0.028 in

8 mm
0.315 in

30 mm
1.181 in

0.7 mm
0.028 in

25 mm
0.984 in

STATIC
ELECTRICITY
PREVENTION
DEVICES

0.5 mm
0.020 in
30 mm
1.181 in

LASER
MARKERS
PLC

30 mm
1.181 in

HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

Sensor mounting bracket


MS-CX2-1

MS-CX2-2

45

45
Mounting
Angle adjustment: 45 hole for
M6 screw

FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS

Two M3 (length 12 mm
0.472 in) screws with
washers are attached.

Two M3 (length 12 mm
0.472 in) screws with
washers are attached.

MS-CX2-4

MS-CX2-5
Selection
Guide
Amplifier
Built-in

Height
adjustment:
150 mm
5.906 in
approx.

Power Supply
Built-in

Two M3 (length 14 mm
0.551 in) screws with
washers are attached.

Two M3 (length 12 mm
0.472 in) screws with
washers are attached.

MS-CX-3

Amplifierseparated

CX-400
CY-100
EX-10
EX-20
EX-30

MS-AJ2-M

Swivel:
360 rotation
Height
adjustment:
150 mm
5.906 in
approx.

WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS

Mounting hole
for M6 screw
Mounting
hole for
M6 screw

PRESSURE /
FLOW
SENSORS

PARTICULAR
USE
SENSORS

Two M4 (length 10 mm
0.394 in) screws with
washers are attached.

Swivel:
360 rotation
45

LIGHT
CURTAINS /
SAFETY
COMPONENTS

INDUCTIVE
PROXIMITY
SENSORS

MS-AJ1-M

MS-AJ2-A

MS-AJ2

MS-RF23

Lateral arm assembly

Universal sensor mounting stand

Two M3 (length 8 mm
0.315 in) screws with
washers are attached.

RF-13

Notes: 1) The plug-in connector type sensor does not allow use of some sensor mounting brackets
because of the protrusion of the connector.
2) Refer to p.979 for details of the universal sensor mounting stand MS-AJ series.
3) Refer to p.980 for details of the sensor checker CHX-SC2.
4) Set the distance between the sensor and the reflective tape to 0.1 m 0.328 ft (CX-482: 0.4 m
1.312 ft) or more.
5) Set the distance between the sensor and the reflective tape to 0.2 m 0.656 ft or more.

Swivel:
360 rotation

Two M3 (length 12 mm
0.472 in) screws with
washers are attached.

RF-11

Foot biangled mounting bracket


It can also be used for mounting RF-210. The thru-beam type
sensor needs two
brackets.
Protective mounting bracket

MS-CX2-2

MS-AJ1

PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS

For RF-230

Sensing range (Note 4):


0.5 m 1.640 ft [CX-491]
0.8 m 2.625 ft [CX-493]

RF-11

Universal
sensor
mounting stand
(Note 2)

MS-RF22

For RF-220

MS-RF23

Sensor
mounting
bracket (Note 1)

MS-RF21-1

Protective mounting bracket for RF-210


It protects the reflector from damage and maintains alignment.

MS-RF22

Reflective tape

LASER
SENSORS

Reflector mounting bracket

Description

Swivel:
360 rotation
45
45
Elevation
angle: 45

Height
adjustment:
150 mm
5.906 in
approx.

EX-40

Two M3 (length 12 mm 0.472 in)


screws with washers are attached.

CX-440
EQ-30

Sensor checker

EQ-500

CHX-SC2

MQ-W
PO

ER

Mounting hole
for M6 screw

LE

VE

X-

SC

RX-LS200
RX

Sensor checker

RT-610

287

Compact Photoelectric Sensor

SPECIFICATIONS

FIBER
SENSORS
LASER
SENSORS

Standard type

PHOTOELECTRIC
SENSORS

AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS

Item

LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS

Sensing object

50 mm 1.969 in
or more opaque,
12 mm 0.472 in
translucent or
or more opaque object (Note 4)
specular object
(Note 2, 5)

Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

15 m
49.213 ft

30 m
98.425 ft

CY-100
EX-10
EX-20
EX-30
EX-40
CX-440

1 mm 0.039 in or less

Emitter: 15 mA or less Emitter: 20 mA or less Emitter: 25 mA or less


Receiver: 10 mA or less Receiver: 10 mA or less Receiver: 10 mA or less

13 mA
or less

10 mA or less

<NPN output type>


NPN open-collector transistor

Maximum sink current: 100 mA

Applied voltage: 30 V DC or less (between output and 0 V)

Residual voltage: 2 V or less (at 100 mA sink current)
1 V or less (at 16 mA sink current)

Output

Output operation

Opaque, translucent
or transparent
object (Note 5)
Min. sensing object: 0.5 mm
0.020 in copper wire

()
0.5 mm 0.020 in or less

13 mA or less

15 mA or less

<PNP output type>


PNP open-collector transistor

Maximum source current: 100 mA

Applied voltage: 30 V DC or less (between output and +V)

Residual voltage: 2 V or less (at 100 mA source current)
1 V or less (at 16 mA source current)

Switchable either Light-ON or Dark-ON

Short-circuit protection

Incorporated

Response time

1 ms or less

Operation indicator

2 ms or less

1 ms or less

Orange LED (lights up when the output is ON)(incorporated on the receiver for thru-beam type)

Stability indicator

Green LED (lights up under stable light received condition or stable dark condition)(incorporated on the receiver for thru-beam type)
Green LED (lights up when the
power is ON) (incorporated on the
emitter)

Power indicator
Sensitivity adjuster

Continuously variable adjuster (incorporated on the receiver for thru-beam type)


Two units of sensors
can be mounted close
together with interference
prevention filters. (Sensing
range: 5 m 16.404 ft)

Automatic interference
prevention function

Incorporated (Two units of sensors can be mounted close together.)

Protection

IP67 (IEC)

Ambient temperature

-25 to +55 C -13 to +131 F (No dew condensation or icing allowed), Storage: -30 to +70 C -22 to +158 F

Ambient humidity

35 to 85 % RH, Storage: 35 to 85 % RH

Ambient illuminance

Incandescent light: 3,000 x at the light-receiving face

Voltage withstandability

1,000 V AC for one min. between all supply terminals connected together and enclosure

Insulation resistance

20 M, or more, with 250 V DC megger between all supply terminals connected together and enclosure

Vibration resistance

10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each

Shock resistance

500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each

Emitting element (modulated)

Red LED

Infrared LED

Red LED

Peak emission wavelength 680 nm 0.027 mil 870 nm 0.034 mil 850 nm 0.033 mil 680 nm 0.027 mil 650 nm 0.026 mil
Material

Infrared LED

Infrared LED

Red LED

870 nm 0.034 mil

860 nm 0.033 mil

645 nm 0.025 mil

Enclosure: PBT (Polybutylene terephthalate), Lens: Acrylic (CX-48: Polycarbonate), Indicator cover: Acrylic (CX-48: Polycarbonate)
0.2 mm2 3-core (thru-beam type emitter: 2-core) cabtyre cable, 2 m 6.562 ft long

Cable extension

Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (thru-beam type: both emitter and receiver)

Net

Weight

Emitter: 45 g approx., Receiver: 50 g approx.

Gross

50 g approx.

100 g approx.

80 g approx.

60 g approx.

RF-230 (Reflector): 1 pc.

Accessories

Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F.

2) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-230 reflector. The sensing range represents the
actual sensing range of the sensor. The sensing range : A of the table below may vary depending on the shape of sensing object. Be sure to check the
operation with the actual sensing object.
Sensing
range: A

MQ-W

RT-610

Opaque, translucent or
transparent object (Note 5)

12 to 24 V DC 10 % Ripple P-P 10 % or less

Current consumption

EQ-500

RX

50 mm 1.969 in or more
transparent, translucent or
opaque object (Note 2, 5)

0.5 mm 0.020 in or less

Supply voltage

EQ-30

RX-LS200

50 mm 1.969 in
or more opaque
or translucent
object (Note 2, 5)

15 % or less of operation distance (Note 3)

Repeatability (perpendicular to sensing axis)

Cable
CX-400

3 m 9.843 ft 5 m 16.404 ft 50 to 500 mm 50 to 1,000 mm 0.1 to 2 m


100 mm
300 mm
800 mm
70 to 300 mm
(Note 2)
(Note 2)
1.969 to 19.685 in (Note 2) 1.969 to 39.37 in (Note 2) 0.328 to 6.562 ft (Note 2) 3.937 in (Note 3) 11.811 in (Note 3) 31.496 in (Note 3) 2.756 to 11.811 in (Note 3)

Hysteresis

Environmental resistance

UV
CURING
SYSTEMS

Narrow-view

PNP output CX-411-P CX-412-P CX-413-P CX-491-P CX-493-P CX-481-P CX-483-P CX-482-P CX-424-P CX-421-P CX-422-P CX-423-P
10 m
32.808 ft

MACHINE
VISION
SYSTEMS

Diffuse reflective

Long sensing range With polarizing filters Long sensing range For transparent object sensing

Sensing range

MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES

Retroreflective

NPN output CX-411 CX-412 CX-413 CX-491 CX-493 CX-481 CX-483 CX-482 CX-424 CX-421 CX-422 CX-423

SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS

Thru-beam

Type
Model No.

MICRO
PHOTOELECTRIC
SENSORS

CX-400 SERIES Ver.2

Sensor

CX-491

CX-493

Sensing
object

0 to 3 m
0 to 9.843 ft

0 to 5 m
0 to 16.404 ft

Setting range
of the reflector: B

0.1 to 3 m
0.1 to 5 m
0.328 to 9.843 ft 0.328 to 16.404 ft

CX-481

CX-483

CX-482

50 to 1,000 mm
50 to 500 mm
1.969 to 19.685 in 1.969 to 39.37 in

0.1 to 2 m
0.328 to 6.562 ft

100 to 500 mm 100 to 1,000 mm


3.937 to 19.685 in 3.937 to 39.37 in

0.8 to 2 m
2.625 to 6.562 ft

Reflector

3)
The sensing range and hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 200 mm 7.874 7.874 in) as the object.

4) If slit masks (optional) are fitted, an object of 0.5 mm 0.020 in (using round slit mask) can be detected.

5) Make sure to confirm detection with an actual sensor before use.

Compact Photoelectric Sensor

CX-400 SERIES Ver.2

SPECIFICATIONS

FIBER
SENSORS
LASER
SENSORS

Standard type

Model No.

Type

Item

PHOTOELECTRIC
SENSORS

Adjustable range reflective

Small spot

NPN output

CX-441

CX-443

CX-444

CX-442

MICRO
PHOTOELECTRIC
SENSORS

PNP output

CX-441-P

CX-443-P

CX-444-P

CX-442-P

AREA
SENSORS

Adjustable range (Note 2)

20 to 50 mm 0.787 to 1.969 in

20 to 100 mm 0.787 to 3.937 in 40 to 300 mm 1.575 to 11.811 in

Sensing range (with white non-glossy paper)

2 to 50 mm 0.079 to 1.969 in

15 to 100 mm 0.591 to 3.937 in 20 to 300 mm 0.787 to 11.811 in

LIGHT
CURTAINS /
SAFETY
COMPONENTS

5 % or less of operation distance

PRESSURE /
FLOW
SENSORS

Hysteresis
(with white non-glossy paper)
Repeatability

2 % or less of operation distance

Along sensing axis: 1 mm 0.039 in or less, Perpendicular to sensing axis: 0.2 mm 0.008 in or less (with white non-glossy paper)

Supply voltage

12 to 24 V DC 10 % Ripple P-P 10 % or less

Current consumption

Output operation
Short-circuit protection

Orange LED (lights up when the output is ON)

5-turn mechanical adjuster

Sensing mode

PLC

BGS / FGS functions Switchable with wiring of sensing mode selection input

Automatic interference prevention function (Note 4)

Incorporated

Protection

IP67 (IEC)

Ambient temperature

25 to +55 C 13 to +131 F (No dew condensation or icing allowed), Storage: 30 to +70 C 22 to +158 F

Ambient humidity

35 to 85 % RH, Storage: 35 to 85 % RH

Ambient illuminance

1,000 V AC for one min. between all supply terminals connected together and enclosure

Insulation resistance

20 M, or more, with 250 V DC megger between all supply terminals connected together and enclosure

Vibration resistance

10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max) in X, Y and Z directions for two hours each

Shock resistance

HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS

Incandescent light: 3,000 x at the light-receiving face

Voltage withstandability

WIRE-SAVING
SYSTEMS

LASER
MARKERS

Green LED (lights up under stable operating condition) (Note 3)

Distance adjuster

SIMPLE
WIRE-SAVING
UNITS

STATIC
ELECTRICITY
PREVENTION
DEVICES

1 ms or less

Stability indicator

SENSOR
OPTIONS

MEASUREMENT
SENSORS

Incorporated

Operation indicator

Environmental resistance

<PNP output type>


PNP open-collector transistor

Maximum source current: 100 mA

Applied voltage: 30 V DC or less (between output and +V)

Residual voltage: 2 V or less (at 100 mA source current)
1 V or less (at 16 mA source current)

Switchable either Detection-ON or Detection-OFF

Response time

INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS

20 mA or less
<NPN output type>
NPN open-collector transistor

Maximum sink current: 100 mA

Applied voltage: 30 V DC or less (between output and 0 V)

Residual voltage: 2 V or less (at 100 mA sink current)
1 V or less (at 16 mA sink current)

Output

UV
CURING
SYSTEMS

500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each

Emitting element

Red LED (Peak emission wavelength: 650 nm 0.026 mil, modulated)


2 mm 0.079 in approx.
(at 50 mm 1.969 in distance)

Spot diameter
Material

6.5 mm 0.256 in approx.


(at 50 mm 1.969 in distance)

9 mm 0.354 in approx.
(at 100 mm 3.937 in distance)

15 mm 0.591 in approx.
(at 300 mm 11.811 in distance)

Enclosure: PBT (Polybutylene terephthalate), Lens: Polycarbonate, Indicator cover: Polycarbonate

Cable

0.2 mm2 4-core cabtyre cable, 2 m 6.562 ft long

Cable extension

Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.

Weight

Net weight: 55 g approx., Gross weight: 65 g approx.

Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F.

2) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can detect an object
2 mm 0.079 in [CX-444(-P): 15 mm 0.591 in, CX-442(-P): 20 mm 0.787 in], or more, away.
Actual sensing range
of the sensor: A

Adjustable range: B
Sensing
object

288

Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

CX-400
CY-100
EX-10

CX-441/443

CX-444

CX-442

EX-20

2 to 50 mm
0.079 to 1.969 in

15 to 100 mm
0.591 to 3.937 in

20 to 300 mm
0.787 to 11.811 in

EX-30

20 to 50 mm
0.787 to 1.969 in

20 to 100 mm
0.787 to 3.937 in

40 to 300 mm
1.575 to 11.811 in

3) Refer to Stability indicator (p.299) of PRECAUTIONS FOR PROPER USE for operation of the stability indicator.
4) Note that detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure to
check the operation with the actual sensing object.

EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

289

Compact Photoelectric Sensor

SPECIFICATIONS

FIBER
SENSORS
LASER
SENSORS

CX-400 SERIES Ver.2

Basic type

PHOTOELECTRIC
SENSORS

Thru-beam
Type

AREA
SENSORS

Model No.

MICRO
PHOTOELECTRIC
SENSORS

Item

LIGHT
CURTAINS /
SAFETY
COMPONENTS

Long sensing range


Dark-ON

Light-ON

Dark-ON

Light-ON

Dark-ON

NPN output

CX-411A-C05

CX-411B-C05

CX-412A-C05

CX-412B-C05

CX-491A-C05-Y

CX-491B-C05-Y

PNP output

CX-411A-P-C05

CX-411B-P-C05

CX-412A-P-C05

10 m 32.808 ft

PRESSURE /
FLOW
SENSORS

Sensing object

INDUCTIVE
PROXIMITY
SENSORS

Hysteresis

PARTICULAR
USE
SENSORS

Supply voltage

SENSOR
OPTIONS

Current consumption

12 mm 0.472 in or more opaque object (Note 3)

<NPN output type>


NPN open-collector transistor

Maximum sink current: 100 mA

Applied voltage: 30 V DC or less (between output and 0 V)

Residual voltage: 2 V or less (at 100 mA sink current)
1 V or less (at 16 mA sink current)

Short-circuit protection

Orange LED (lights up when the output is ON)(incorporated on the receiver for thru-beam type)
Green LED (lights up under stable light received condition or stable dark condition)(incorporated on the receiver for thru-beam type)

Power indicator

Green LED (lights up when the power is ON) (incorporated on the emitter)

Sensitivity adjuster
Two units of sensors can be mounted
close together with interference prevention
filters. (Sensing range: 5 m 16.404 ft)

Automatic interference
prevention function
Environmental resistance

FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS

IP67 (IEC)

Ambient temperature

25 to +55 C 13 to +131 F (No dew condensation or icing allowed), Storage: 30 to +70 C 22 to +158 F

Ambient humidity

35 to 85 % RH, Storage: 35 to 85 % RH

Ambient illuminance

Incandescent light: 3,000 x at the light-receiving face

Voltage withstandability

1,000 V AC for one min. between all supply terminals connected together and enclosure

Insulation resistance

20 M, or more, with 250 V DC megger between all supply terminals connected together and enclosure

Vibration resistance

10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each

Emitting element (modulated)


Peak emission wavelength

Selection
Guide

Material

Amplifier
Built-in

Infrared LED

Red LED

870 nm 0.034 mil

680 nm 0.027 mil

0.2 mm2 3-core (thru-beam type emitter: 2-core) cabtyre cable, 0.5 m 1.640 ft long

Cable extension

Amplifierseparated

Red LED
680 nm 0.027 mil

Enclosure: PBT (Polybutylene terephthalate), Lens: Acrylic, Indicator cover: Acrylic

Cable

Power Supply
Built-in

Incorporated (Two units of sensors can


be mounted close together.)

Protection

Shock resistance

Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (thru-beam type: both emitter and receiver)
Net

Weight

EX-10

Emitter: 20 g approx., Receiver: 20 g approx.

20 g approx.

50 g approx.

30 g approx.

Gross

Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F.

2) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-230 reflector (optional). The sensing range
represents the actual sensing range of the sensor. The sensing range : A of the table below may vary depending on the shape of sensing object. Be
sure to check the operation with the actual sensing object.

EX-20

Sensing
range: A

EX-30

CX-491

EX-40

Sensing
object

0 to 3 m
0 to 9.843 ft

CX-440

Setting range
of the reflector: B

0.1 to 3 m
0.328 to 9.843 ft

EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

<PNP output type>


PNP open-collector transistor

Maximum source current: 100 mA

Applied voltage: 30 V DC or less (between output and +V)

Residual voltage: 2 V or less (at 100 mA source current)
1 V or less (at 16 mA source current)

1 ms or less

Stability indicator

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

CY-100

13 mA or less

Incorporated

Operation indicator

HUMAN
MACHINE
INTERFACES

CX-400

Emitter: 20 mA or less
Receiver: 10 mA or less

Response time

PLC

50 mm 1.969 in or more transparent,


translucent or opaque object (Note 2, 4)

0.5 mm 0.020 in or less

Emitter: 15 mA or less
Receiver: 10 mA or less

Output

LASER
MARKERS

3 m 9.843 ft (Note 2)

12 to 24 V DC 10 % Ripple P-P 10 % or less

SIMPLE
WIRE-SAVING
UNITS

STATIC
ELECTRICITY
PREVENTION
DEVICES

CX-412B-P-C05 CX-491A-P-C05-Y CX-491B-P-C05-Y

15 m 49.213 ft

Repeatability (perpendicular to sensing axis)

MEASUREMENT
SENSORS

With polarizing filters

Light-ON

Sensing range

WIRE-SAVING
SYSTEMS

Retroreflective

Sensor

Reflector
(Optional)

3) If slit masks (optional) are fitted, an object of 0.5 mm 0.020 in (using round slit mask) can be detected.
4) Make sure to confirm detection with an actual sensor before use.

Compact Photoelectric Sensor

CX-400 SERIES Ver.2

I/O CIRCUIT AND WIRING DIAGRAMS

FIBER
SENSORS
LASER
SENSORS

NPN output type


I/O circuit diagram

Sensor circuit

Tr

Color code / Connector pin No. of the connector type

Wiring diagram

PHOTOELECTRIC
SENSORS

Brown

(Brown / 1) +V

(Black / 4)
Output (Note 1)

D
ZD
ZD

Black (Note 1)

Load

100 mA max.
(Blue / 3) 0 V
(Pink / 2) Sensing mode
selection input (Note 2, 3)

Internal circuit

12 to 24 V DC
10 %

Load

12 to 24 V DC
10 %

Blue
Pink (Note 2, 3)

Users circuit

Notes: 1) The emitter of the thru-beam type sensor does not incorporate the black wire.
2) T
 he pink wire is incorporated only for the CX-44 adjustable range
reflective type. When using the CX-44, be sure to wire the pink
wire as mentioned *1. Unstable operation may occur.
3) W
 hen the mating cable is connected to the plug-in connector type
of CX-44, its color is white.

*1

BGS function: Connect to 0 V


FGS function: Connect to +V

M8 plug-in connector type

BGS function: Connect to 0 V


FGS function: Connect to +V

2
Sensing mode
selection input
(Note 2)

Symbols ... D : Reverse supply polarity protection diode


ZD : Surge absorption zener diode
Tr : NPN output transistor

2
Not
connected

3
0V

3
0V

4
Output (Note 1)

PNP output type

Sensor circuit

Color code / Connector pin No. of the connector type

Wiring diagram

LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

MACHINE
VISION
SYSTEMS

Brown

(Brown / 1) +V
100 mA max.
(Black / 4) Output (Note 1)
(Blue / 3) 0 V

Load

12 to 24 V DC
10 %

Users circuit

Notes: 1) The emitter of the thru-beam type sensor does not incorporate the
output.
2) Sensing mode selection input is incorporated only for the
CX-44-P adjustable range reflective type. When using the
CX-44-P, be sure to wire the sensing mode selection input (pink /
2) as mentioned *1. Unstable operation may occur.
3) When the mating cable is connected to the plug-in connector type
of CX-44-P, its color is white.

*1

Sensing mode selection input

BGS function: Connect to 0 V


FGS function: Connect to +V

Symbols ... D : Reverse supply polarity protection diode


ZD : Surge absorption zener diode
Tr : PNP output transistor

Black (Note 1)
Load

Blue

12 to 24 V DC
10 %

UV
CURING
SYSTEMS

*1

*1
(Pink / 2) Sensing mode
selection input (Note 2, 3)

Internal circuit

MEASUREMENT
SENSORS

FA
COMPONENTS

I/O circuit diagram

D
D

PARTICULAR
USE
SENSORS

STATIC
ELECTRICITY
PREVENTION
DEVICES

+V

Notes: 1) The emitter of the thru-beam type sensor does not incorporate the output.
2) S
 ensing mode selection input is incorporated only for the
CX-44 adjustable range reflective type. When using the
CX-44, be sure to wire the sensing mode selection input (pink /
2). Unstable operation may occur.

ZD
ZD

INDUCTIVE
PROXIMITY
SENSORS

SIMPLE
WIRE-SAVING
UNITS

M12 pigtailed type

4
Output
(Note 1)

+V

PRESSURE /
FLOW
SENSORS

WIRE-SAVING
SYSTEMS

Connector pin position

Sensing mode selection input

AREA
SENSORS

SENSOR
OPTIONS

Sensing mode selection input

*1

MICRO
PHOTOELECTRIC
SENSORS

LIGHT
CURTAINS /
SAFETY
COMPONENTS

*1

*1

Notes: 1) The emitter of the thru-beam type sensor does not incorporate the
output.
2) Sensing mode selection input is incorporated only for the
CX-44 adjustable range reflective type. When using the
CX-44, be sure to wire the sensing mode selection input (pink / 2)
as mentioned *1. Unstable operation may occur.
3) When the mating cable is connected to the plug-in connector type
of CX-44, its color is white.

Tr

290

Pink (Note 2, 3)

Notes: 1) The emitter of the thru-beam type sensor does not incorporate the black wire.
2) T
 he pink wire is incorporated only for the CX-44-P adjustable range
reflective type. When using the CX-44-P, be sure to wire the pink
wire as mentioned *1. Unstable operation may occur.
3) W
 hen the mating cable is connected to the plug-in connector type
of CX-44-P, its color is white.

*1

Sensing mode selection input

M8 plug-in connector type

2
Sensing mode
selection input
(Note 2)
1

+V

4
Output (Note 1)

3
0V

Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

CX-400

BGS function: Connect to 0 V


FGS function: Connect to +V

Connector pin position

Selection
Guide

CY-100
EX-10

M12 pigtailed type


2
Not
connected

1
+V

EX-20
EX-30
EX-40
CX-440
EQ-30

3
0V

4
Output (Note 1)

Notes: 1) The emitter of the thru-beam type sensor does not incorporate the output.
2) S
 ensing mode selection input is incorporated only for the
CX-44-P adjustable range reflective type. When using the
CX-44-P, be sure to wire the sensing mode selection input (pink /
2). Unstable operation may occur.

EQ-500
MQ-W
RX-LS200
RX
RT-610

291

SENSING CHARACTERISTICS (TYPICAL)

FIBER
SENSORS

CX-411

Thru-beam type
Parallel deviation with round
slit masks (0.5 mm 0.020 in)

0
400
15.748

PARTICULAR
USE
SENSORS
SENSOR
OPTIONS

Parallel deviation with round


slit masks (2 mm 0.079 in)

0
100
3.937

HUMAN
MACHINE
INTERFACES

FA
COMPONENTS
MACHINE
VISION
SYSTEMS

Receiver

15
49.213

15
49.213

Setting distance L (m ft)

20
65.617

0
1,000
39.370

EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

Setting distance L (mm in)

2 Horizontal
6.562 direction
Emitter
1
3.281

20
0
20
40
0.787
0.787
1.575
Center
Left
Right
Operating point (mm in)

Parallel deviation with rectangular


slit masks (2 6 mm 0.079 0.236 in)
Slit on one side
Horizontal
direction

6
19.685

Slit on both sides


Horizontal
direction

Vertical
direction
Emitter

Slit on both sides


Vertical direction

Slit on one side


Vertical
direction

4
Slit on both sides Slit on both sides
Horizontal
13.123 Horizontal
Vertical direction
direction
direction
Emitter

Receiver
Receiver
0
200
100
100
200
0
3.937
7.874
3.937
7.874
(Down) Left
Right (Up)
Center
Operating point (mm in)

Emitter

Receiver

800
31.496

2
6.562

10
32.808

Receiver

5
16.404

20
0
20
Center
Left
Right
Operating angle ( )

1
3.281
0
400
15.748

Slit on
both sides
Emitter

Receiver
200
0
200
400
7.874
7.874 15.748
Center
Left
Right
Operating point (mm in)

Slit on one side Slit on one side


Horizontal Vertical
direction
direction

3
9.843
2
6.562 Horizontal
direction
Emitter
1
3.281

Vertical
direction
Emitter

Receiver
Receiver
0
400
200
0
200
400
15.748 7.874
7.874 15.748
(Down) Left
Right (Up)
Center
Operating point (mm in)

Receiver

Parallel deviation with rectangular


slit masks (1 6 mm 0.039 0.236 in)

Horizontal
2 direction
6.562 Emitter

1.5
4.921
1
3.281

Emitter

0.5
1.640

Receiver
Receiver
0
400
200
0
200
400
15.748 7.874
7.874 15.748
(Down) Left
Right (Up)
Center
Operating point (mm in)

Receiver
100
0
100
200
3.937
3.937
7.874
Center
Left
Right
Operating point (mm in)

Parallel deviation with rectangular


slit masks (2 6 mm 0.079 0.236 in)
Slit on one side Slit on one side
Horizontal
Vertical
direction
direction

6
19.685

Vertical
direction
Emitter

Slit on
both sides

8
26.247

Slit on one side Slit on one side


Vertical
Horizontal
direction
direction

Slit on both sides


Horizontal and
Vertical direction

Slit on
one side

0
200
7.874

0
50
50
100
1.969
1.969
3.937
Center
Left
Right
Operating point (mm in)

4
13.123

Slit on both sides


Horizontal and
Vertical direction

Slit on
both sides

0
100
3.937

40

4
13.123

Slit on
one side

Emitter

200
7.874

4
13.123

2
6.562

Parallel deviation with round


slit masks (1 mm 0.039 in)
2
6.562

400
15.748

Parallel deviation with rectangular


slit masks (0.5 6 mm 0.020 0.236 in)

3
9.843

Vertical
direction
Emitter

Receiver
Receiver
0
200
100
100
200
0
7.874
3.937
3.937
7.874
(Down) Left
Right (Up)
Center
Operating point (mm in)

Slit on
one side

600
23.622

Emitter

0
40

500
500
1,000
0
19.685
19.685 39.370
Center
Left
Right
Operating point (mm in)

Parallel deviation with round


slit masks (0.5 mm 0.020 in)

Parallel deviation with round


slit masks (2 mm 0.079 in)

Setting distance L (m ft)

EX-10

Vertical
direction
Emitter

Angular deviation

20
65.617

5
16.404

Amplifierseparated

CY-100

Slit on
both sides
Horizontal
direction

Receiver

0
40
1.575

8
26.247

Slit on one side Slit on one side


Vertical
Horizontal
direction
direction

Thru-beam type

Parallel deviation

Power Supply
Built-in

CX-400

Slit on
both sides
Vertical
direction

Receiver
Receiver
0
100
50
50
100
0
3.937
1.969
1.969
3.937
(Down) Left
Right (Up)
Center
Operating point (mm in)

50
0
50
100
1.969
1.969
3.937
Center
Left
Right
Operating point (mm in)

10
32.808

Amplifier
Built-in

Horizontal
1 direction
3.281 Emitter

Parallel deviation with rectangular


slit masks (1 6 mm 0.039 0.236 in)

Emitter

CX-412

UV
CURING
SYSTEMS

Selection
Guide

Emitter

PLC

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

Slit on
both sides

1
3.281

Slit on
both sides

Receiver

3
9.843

Slit on one side


Horizontal
direction

400
15.748

0
10
10
20
0.394
0.394
0.787
Center
Left
Right
Operating point (mm in)

4
13.123

Slit on one side


Vertical
direction

2
6.562

0
20
0.787

40

Parallel deviation with rectangular


slit masks (0.5 6 mm 0.020 0.236 in)

Slit on
one side

2
6.562

20
0
20
Center
Left
Right
Operating angle ( )

Slit on
one side

Setting distance L (m ft)

LASER
MARKERS

0
40

800
31.496

Setting distance L (m ft)

STATIC
ELECTRICITY
PREVENTION
DEVICES

Setting distance L (m ft)

WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS

Setting distance L (m ft)

Receiver

Emitter

Slit on
both sides

200
7.874

Receiver

200
200
400
0
7.874
7.874 15.748
Center
Left
Right
Operating point (mm in)

Slit on
one side

Setting distance L (mm in)

SIMPLE
WIRE-SAVING
UNITS

5
16.404

Setting distance L (m ft)

INDUCTIVE
PROXIMITY
SENSORS

Emitter

5
16.404

400
15.748

Emitter

Setting distance L (m ft)

PRESSURE /
FLOW
SENSORS

Setting distance L (m ft)

LIGHT
CURTAINS /
SAFETY
COMPONENTS

10
32.808

10
32.808

Setting distance L (m ft)

AREA
SENSORS

Parallel deviation with round


slit masks (1 mm 0.039 in)

Setting distance L (mm in)

Angular deviation

Setting distance L (m ft)

Parallel deviation

MICRO
PHOTOELECTRIC
SENSORS

Setting distance L (m ft)

PHOTOELECTRIC
SENSORS

Please contact our office for the sensing characteristics of CX-413 and CX-483.

Setting distance L (m ft)

LASER
SENSORS

CX-400 SERIES Ver.2

Compact Photoelectric Sensor

Slit on both sides


Horizontal and
Vertical direction

4 Horizontal
13.123 direction
Emitter
2
6.562

Vertical
direction
Emitter

Receiver
Receiver
0
800
400
400
800
0
31.496 15.748
15.748 31.496
(Down) Left
Right (Up)
Center
Operating point (mm in)

Compact Photoelectric Sensor

SENSING CHARACTERISTICS (TYPICAL)

Angular deviation

4
13.123

4
13.123
Reflector
(RF-230)

2
6.562

1
3.281

1
3.281
0
200
7.874

Sensor
angular
deviation
Reflector (RF-230)
L

2
6.562

Sensor

0
40

100
0
100
200
3.937
3.937
7.874
Center
Left
Right
Operating point (mm in)

CX-481

20
0
20
Center
Left
Right
Operating angle ( )

Setting distance L (mm in)

Setting distance L (mm in)

400
15.748

Sensor

200
7.874

Sensor
Reflector
angular
Reflector
deviation
angular Reflector (RF-230)
deviation

200
7.874
0
40

50
0
50
100
1.969
1.969
3.937
Center
Left
Right
Operating point (mm in)

6
19.685

0
200
7.874

40

Sensor angular
deviation
Reflector (RF-230)

400
15.748

6
19.685

Reflector
(RF-230)

Sensor
angular
deviation

L
Sensor

20
0
20
Center
Left
Right
Operating angle ( )

40

CX-482

0
20
0.787

Sensing range L (mm in)

Setting distance L (mm in)

Sensor

100
3.937

a a mm
White non-glossy paper

50
1.969

200
7.874

10
0
10
20
0.394
0.394
0.787
Center
Left
Right
Operating point (mm in)

Sensor
Sensor
20
0
20
40
Center
Left
Right
Operating angle ( )

Sensor

SENSOR
OPTIONS

2
6.562
Reflector
(RF-230)
1
3.281

0
200
7.874

Sensor

100
0
100
200
3.937
3.937
7.874
Center
Left
Right
Operating point (mm in)

1
3.281

0
40

MEASUREMENT
SENSORS

Sensor
angular
deviation
Sensor
angular
deviation
L Reflector
(RF-230)
Sensor

Reflector
angular
deviation
Reflector
angular
deviation
Reflector
L
(RF-230)
Sensor

20
0
20
Center
Left
Right
Operating angle ( )

40

STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS

As the sensing object size becomes smaller than the standard


size (white non-glossy paper 200 200 mm 7.874 7.874 in), the
sensing range shortens, as shown in the left graph.
For plotting the left graph, the sensitivity has been set such that
a 200 200 mm 7.874 7.874 in white non-glossy paper is just
detectable at a distance of 100 mm 3.937 in.

MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS

Selection
Guide

50
100
150
1.969
3.937
5.906
White non-glossy paper
side length a (mm in)

200
7.874

Amplifier
Built-in
Power Supply
Built-in

As the sensing object size becomes smaller than the standard


size (white non-glossy paper 200 200 mm 7.874 7.874 in), the
sensing range shortens, as shown in the left graph.
For plotting the left graph, the sensitivity has been set such that
a 200 200 mm 7.874 7.874 in white non-glossy paper is just
detectable at a distance of 300 mm 11.811 in.

400
15.748
300
11.811
200
7.874

a a mm
White nonglossy paper

100
3.937

50
100
150
1.969
3.937
5.906
White non-glossy paper
side length a (mm in)

Amplifierseparated

CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30

Sensor
20
0
20
40
0.787
0.787
1.575
Center
Left
Right
Operating point (mm in)

PARTICULAR
USE
SENSORS

WIRE-SAVING
SYSTEMS

2
6.562

Correlation between sensing object size and sensing range


200 200 mm
7.874 7.874 in
White nonglossy paper

INDUCTIVE
PROXIMITY
SENSORS

SIMPLE
WIRE-SAVING
UNITS

Angular deviation

Diffuse reflective type

100
3.937
0
40
1.575

PRESSURE /
FLOW
SENSORS

Sensing range L (mm in)

Setting distance L (mm in)

300
11.811

LIGHT
CURTAINS /
SAFETY
COMPONENTS

Retroreflective type

CX-421
400
15.748

Sensor
Sensor
angular
deviation
Reflector (RF-230)

AREA
SENSORS

Reflector
angular
deviation
Sensor
angular
deviation
Reflector angular
deviation
Reflector
(RF-230)
L

Sensor

Sensing field

LASER
SENSORS

MICRO
PHOTOELECTRIC
SENSORS

Correlation between sensing object size and sensing range

200 200 mm
7.874 7.874 in
White non-glossy paper

FIBER
SENSORS

PHOTOELECTRIC
SENSORS

Diffuse reflective type

Sensing field

50
1.969

2
6.562
0
40

100
0
100
200
3.937
3.937
7.874
Center
Left
Right
Operating point (mm in)

CX-424

100
3.937

4
13.123

Sensor

Parallel deviation

600
23.622

Reflector
(RF-230)

8
26.247

Sensor

800
31.496

600
23.622

8
26.247

2
6.562

Angular deviation

800
31.496

Angular deviation

4
13.123

Retroreflective type

Parallel deviation

0
100
3.937

Sensor
angular
deviation
Reflector
angular
deviation
Reflector (RF-230)

Sensor

Parallel deviation

Setting distance L (m ft)

3
9.843

Setting distance L (m ft)

Setting distance L (m ft)

3
9.843

Reflector
angular
deviation

Retroreflective type

Setting distance L (m ft)

Parallel deviation

CX-493

Setting distance L (m ft)

Retroreflective type

Please contact our office for the sensing characteristics of CX-413 and CX-483.

Setting distance L (m ft)

CX-491

292

CX-400 SERIES Ver.2

EQ-500
200
7.874

MQ-W
RX-LS200
RX
RT-610

293

Compact Photoelectric Sensor

SENSING CHARACTERISTICS (TYPICAL)

FIBER
SENSORS

PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS

1,000
39.370

SIMPLE
WIRE-SAVING
UNITS

200 200 mm
7.874 7.874 in
White nonglossy paper

500
19.685

LASER
MARKERS

200
7.874
N6
100 200 200 mm
3.937 7.874 7.874 in
Non-glossy paper

Amplifier
Built-in

Amplifierseparated

CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

200
7.874

As the sensing object size becomes smaller than the standard


size (white non-glossy paper 200 200 mm 7.874 7.874 in), the
sensing range shortens, as shown in the left graph.

White

100
3.937

L
Sensor

2
0.079

For plotting the left graph, the sensitivity has been set such
that a 200 200 mm 7.874 7.874 in white non-glossy paper
is just detectable at a distance of 200 mm 7.874 in. Contact us
for the sensing characteristics of 300 mm 11.811 in distance.
Please contact us for the sensing field at the setting distance
300 mm 11.811 in.

N6
a a mm
Non-glossy paper

L
Sensor

1
0
1
2
0.039
0.039
0.079
Center
Left
Right
Operating point (mm in)

50
100
150
1.969
3.937
5.906
Non-glossy paper
side length a (mm in)

200
7.874

Correlation between lightness and sensing range

Sensing range L (mm in)

200
7.874

Sensing
region

Power Supply
Built-in

50
100
150
1.969
3.937
5.906
White non-glossy paper
side length a (mm in)

200
7.874

100
3.937

Selection
Guide

Correlation between sensing object size and sensing range

FA
COMPONENTS

UV
CURING
SYSTEMS

Sensor

White

HUMAN
MACHINE
INTERFACES

MACHINE
VISION
SYSTEMS

Diffuse reflective type

Sensing field

PLC

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

a a mm
White nonglossy paper

400
15.748

CX-423

Setting distance L (mm in)

STATIC
ELECTRICITY
PREVENTION
DEVICES

As the sensing object size becomes smaller than the standard


size (white non-glossy paper 200 200 mm 7.874 7.874 in), the
sensing range shortens, as shown in the left graph.
For plotting the left graph, the sensitivity has been set such that
a 200 200 mm 7.874 7.874 in white non-glossy paper is just
detectable at a distance of 800 mm 31.496 in.

800
31.496

20
0
20
40
0.787
0.787
1.575
Center
Left
Right
Operating point (mm in)

WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS

Sensor
0
40
1.575

PARTICULAR
USE
SENSORS
SENSOR
OPTIONS

Correlation between sensing object size and sensing range

Dark

N2

N4
N6
Lightness

N8

The sensing region is


represented by oblique lines in
the left figure.
However, the sensitivity should
be set with an enough margin
because of slight variation in
products.

Emitted beam
250
9.843
200
7.874
150
5.906
110
4.331
100
3.937

2.5 mm
0.098 in
2 mm
0.079 in
2.2 mm
0.087 in

50
1.969

4 mm
0.157 in

0
Light

N1 N2 N3 N4 N5 N6 N7 N8 N9

Lightness shown on the left may


differ slightly from the actual
object condition.

5 mm
0.197 in
Visible spot range

LIGHT
CURTAINS /
SAFETY
COMPONENTS

Sensing field

Distance L (mm in)

AREA
SENSORS

Diffuse reflective type

Sensing range L (mm in)

MICRO
PHOTOELECTRIC
SENSORS

CX-422

Sensing range L (mm in)

PHOTOELECTRIC
SENSORS

Setting distance L (mm in)

LASER
SENSORS

CX-400 SERIES Ver.2

Compact Photoelectric Sensor

CX-400 SERIES Ver.2

SENSING CHARACTERISTICS (TYPICAL)

FIBER
SENSORS

CX-441

Adjustable range reflective type

Sensing fields
80
3.150

Gray non-glossy paper


Lightness: 5

30
1.181
20
0.787

60
2.362

50 50 mm
1.969 1.969 in
Non-glossy paper

10
0.394

4
0.157

Gray non-glossy paper


Lightness: 5

50 50 mm
1.969 1.969 in
Non-glossy paper

20
0.787

Sensor

White nonglossy paper

40
1.575

0
4
0.157

2
0
2
4
0.079
0.079
0.157
Center
Left
Right
Operating point (mm in)

MICRO
PHOTOELECTRIC
SENSORS

80
3.150

Sensor

LIGHT
CURTAINS /
SAFETY
COMPONENTS

2 mm 0.079 in
2 mm 0.079 in

PRESSURE /
FLOW
SENSORS

3 mm 0.118 in

INDUCTIVE
PROXIMITY
SENSORS

3 mm 0.118 in

2
0
2
4
0.079
0.079
0.157
Center
Left
Right
Operating point (mm in)

Correlation between color


(50 50 mm 1.969 1.969 in construction paper) and sensing range

AREA
SENSORS

60
2.362
50
1.969
40
1.575
30
1.181
20
0.787

Distance L (mm in)

Setting distance L (mm in)

White nonglossy paper

Setting distance L (mm in)

Setting distance: 50 mm 1.969 in

40
1.575

LASER
SENSORS
PHOTOELECTRIC
SENSORS

Emitted beam

Setting distance: 25 mm 0.984 in

294

PARTICULAR
USE
SENSORS
SENSOR
OPTIONS

Correlation between material


(50 50 mm 1.969 1.969 in) and sensing range

SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS

25
0.984

Black rubber

Plywood

mm
25
0.984 in

Cardboard

Black

Blue

Gray

Green

Red

Brown

Orange

White

Yellow

mm
25
0.984 in

Gray non-glossy
paper (Lightness: 5)

25
0.984

mm
50
1.969 in

White nonglossy paper

mm
50
1.969 in

50
1.969

Sensing range L (mm in)

Sensing range L (mm in)

50
1.969

These bars indicate the


sensing range with the
respective colors when
the distance adjuster is
set to a sensing range
of 50 mm 1.969 in and
25 mm 0.984 in long,
respectively, with white
color.
The sensing range also
varies depending on
material.

CX-443

4
0.157

2
0
2
4
0.079
0.079
0.157
Center
Left
Right
Operating point (mm in)

4
0.157

Gray non-glossy paper


Lightness: 5

Correlation between color


(50 50 mm 1.969 1.969 in construction paper) and sensing range

Sensing range L (mm in)

50
1.969

mm
50
1.969 in

25
0.984

Black

Gray

Blue

Green

Brown

Red

Orange

White

Yellow

mm
25
0.984 in

These bars indicate


the sensing range with
the respective colors
when the distance
adjuster is set to a
sensing range of
50 mm 1.969 in and
25 mm 0.984 in long,
respectively, with white
color.
The sensing range
also varies depending
on material.

6.2 mm 0.244 in

FA
COMPONENTS

Selection
Guide

5.3 mm 0.209 in

Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

Correlation between material


(50 50 mm 1.969 1.969 in) and sensing range

50
1.969

mm
50
1.969 in

25
0.984

mm
25
0.984 in
0

HUMAN
MACHINE
INTERFACES

5.9 mm 0.232 in

2
0
2
4
0.079
0.079
0.157
Center
Left
Right
Operating point (mm in)

PLC

6.5 mm 0.256 in

Black rubber

20
0.787

White nonglossy paper

60
2.362
50
1.969
40
1.575
30
1.181
20
0.787

Plywood

10
0.394

Sensor

Cardboard

Gray non-glossy paper


Lightness: 5

Gray non-glossy
paper (Lightness: 5)

40
1.575

White nonglossy paper

White nonglossy paper

60
2.362

LASER
MARKERS

UV
CURING
SYSTEMS

80
3.150

50 50 mm 1.969 1.969 in
Non-glossy paper

Distance L (mm in)

Sensor

20
0.787

80
3.150

Sensing range L (mm in)

30
1.181

Setting distance: 50 mm 1.969 in

Setting distance L (mm in)

Setting distance L (mm in)

50 50 mm 1.969 1.969 in
Non-glossy paper

STATIC
ELECTRICITY
PREVENTION
DEVICES

MACHINE
VISION
SYSTEMS

Emitted beam

Setting distance: 25 mm 0.984 in

MEASUREMENT
SENSORS

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

Adjustable range reflective type

Sensing fields
40
1.575

These bars indicate


the sensing range
with the respective
objects when the
distance adjuster is
set to a sensing range
of 50 mm 1.969 in
and 25 mm 0.984 in
long, respectively,
with white non-glossy
paper.

These bars indicate


the sensing range
with the respective
objects when the
distance adjuster is
set to a sensing range
of 50 mm 1.969 in
and 25 mm 0.984 in
long, respectively,
with white non-glossy
paper.

CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

295

Compact Photoelectric Sensor

SENSING CHARACTERISTICS (TYPICAL)

LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS

Sensing fields

White nonglossy paper

30
1.181
20
0.787

Setting distance: 50 mm 1.969 in

Setting distance: 100 mm 3.937 in

80
3.150

40
1.575

Gray non-glossy paper


Lightness: 5

50 50 mm
1.969 1.969 in
Non-glossy paper
L

0
10
0.394

SENSOR
OPTIONS

40
1.575

Gray non-glossy paper


Lightness: 5

0
10
0.394

5
0
5
10
0.197
0.197
0.394
Center
Left
Right
Operating point (mm in)

100
3.937

50 50 mm
1.969 1.969 in
Non-glossy paper

20
0.787

Sensor

White nonglossy paper

White nonglossy paper

60
2.362

10
0.394

PARTICULAR
USE
SENSORS

SIMPLE
WIRE-SAVING
UNITS

Emitted beam

Setting distance: 25 mm 0.984 in

Setting distance L (mm in)

AREA
SENSORS

Adjustable range reflective type

Setting distance L (mm in)

MICRO
PHOTOELECTRIC
SENSORS

CX-444

Setting distance L (mm in)

PHOTOELECTRIC
SENSORS

Gray non-glossy paper


Lightness: 5

50 50 mm
1.969 1.969 in
Non-glossy paper

50
1.969

Sensor

Sensor

0
10
0.394

5
0
5
10
0.197
0.197
0.394
Center
Left
Right
Operating point (mm in)

Correlation between color


(50 50 mm 1.969 1.969 in construction paper) and sensing range

100
3.937

9 mm 0.354 in

80
3.150

8 mm 0.315 in

50
1.969

6.5 mm 0.256 in

20
0.787

5.3 mm 0.209 in

Distance L (mm in)

FIBER
SENSORS
LASER
SENSORS

CX-400 SERIES Ver.2

5
0
5
10
0.197
0.197
0.394
Center
Left
Right
Operating point (mm in)

Correlation between material


(50 50 mm 1.969 1.969 in) and sensing range

WIRE-SAVING
SYSTEMS

Emitted beam

White nonglossy paper


200
7.874

0
10
0.394

50 50 mm
1.969 1.969 in
Non-glossy paper

100
3.937

0
10
0.394

5
0
5
10
0.197
0.197
0.394
Center
Left
Right
Operating point (mm in)

Sensor
5
0
5
10
0.197
0.197
0.394
Center
Left
Right
Operating point (mm in)

300
11.811

15 mm 0.591 in

200
7.874

11 mm 0.433 in

100
3.937
1.181
30

9 mm 0.354 in
8 mm 0.315 in

Correlation between material


(50 50 mm 1.969 1.969 in) and sensing range

These bars indicate the


sensing range with the
respective colors when
the distance adjuster is
set to a sensing range
of 300 mm 11.811 in,
200 mm 7.874 in and
100 mm 3.937 in long,
respectively, with white
color.
The sensing range also
varies depending on
material.

300
11.811
200
7.874

300 mm
11.811 in
200 mm
7.874 in
100 mm
3.937 in

100
3.937
0

Plywood

200
7.874

Black rubber

RT-610

White nonglossy paper

300
11.811

Cardboard

RX

100
3.937

Black

MQ-W
RX-LS200

0
10
0.394

300 mm
11.811 in
200 mm
7.874 in
100 mm
3.937 in
Gray

EQ-500

200
7.874

Blue

EQ-30

Green

CX-440

Sensor

300
11.811

Brown

EX-40

50 50 mm
1.969 1.969 in
Non-glossy paper

400
15.748

Gray non-glossy paper


Lightness: 5

400
15.748

Red

EX-30

Gray non-glossy paper


Lightness: 5

400
15.748

Orange

EX-20

5
0
5
10
0.197
0.197
0.394
Center
Left
Right
Operating point (mm in)

100
3.937

Setting distance: 300 mm 11.811 in


400
15.748

White nonglossy paper

Correlation between color


(50 50 mm 1.969 1.969 in construction paper) and sensing range

White

EX-10

Sensor

Sensing range L (mm in)

CY-100

50 50 mm
1.969 1.969 in
Non-glossy paper

50
1.969

Amplifierseparated

CX-400

Gray non-glossy paper


Lightness: 5

Yellow

Power Supply
Built-in

Setting distance L (mm in)

Amplifier
Built-in

Setting distance: 200 mm 7.874 in

Distance L (mm in)

Setting distance: 100 mm 3.937 in

100
3.937

Selection
Guide

Plywood

Sensing fields

Gray non-glossy
paper (Lightness: 5)

UV
CURING
SYSTEMS

These bars indicate


the sensing range with
the respective objects
when the distance
adjuster is set to a
sensing range of 100
mm 3.937 in and 50
mm 1.969 in long,
respectively, with white
non-glossy paper.

Adjustable range reflective type

White nonglossy paper

MACHINE
VISION
SYSTEMS

CX-442

Setting distance L (mm in)

FA
COMPONENTS

Black rubber

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

Cardboard

Black

Blue

Gray

Green

Red

Brown

Orange

White

Yellow

0
HUMAN
MACHINE
INTERFACES

mm
50
1.969 in
Gray non-glossy
paper (Lightness: 5)

mm
50
1.969 in

PLC

mm
100
3.937 in

50
1.969

White nonglossy paper

mm
100
3.937 in

Sensing range L (mm in)

50
1.969

100
3.937

Setting distance L (mm in)

LASER
MARKERS

These bars indicate the


sensing range with the
respective colors when
the distance adjuster is
set to a sensing range
of 100 mm 3.937 in
and 50 mm 1.969 in
long, respectively, with
white color.
The sensing range also
varies depending on
material.

Sensing range L (mm in)

STATIC
ELECTRICITY
PREVENTION
DEVICES

100
3.937

Sensing range L (mm in)

MEASUREMENT
SENSORS

These bars indicate


the sensing range with
the respective objects
when the distance
adjuster is set to a
sensing range of
300 mm 11.811 in,
200 mm 7.874 in and
100 mm 3.937 in long,
respectively, with white
non-glossy paper.

Compact Photoelectric Sensor

PRECAUTIONS FOR PROPER USE

CX-400 SERIES Ver.2

296

Refer to p.1458~ for general precautions.

LASER
SENSORS

All models

PHOTOELECTRIC
SENSORS

Never use this product as a sensing device


for personnel protection.
In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.

MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS

Mounting
The tightening
torque should be
0.5 Nm or less.

INDUCTIVE
PROXIMITY
SENSORS

M3
(length 12 mm 0.472 in)
screw with washers Sensor
mounting
bracket
(Optional)

PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS

Others
Do not use during the initial transient time (50 ms) after
the power supply is switched on.

WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES

CX-41 CX-42 CX-49 CX-48


Part description and functions

Beam alignment

Stability indicator (Green) (Note 1)


Lights up under the
stable light condition or
the stable dark condition

Operation indicator (Orange) (Note 2)


Lights up when the sensing
output is ON

Sensitivity adjuster (Note 1)


Sensing range becomes
longer when turned.

Operation mode switch (Note 1)


L: Light-ON
D: Dark-ON

Notes: 1) Not incorporated on the emitter.


2) It is the power indicator (green, lights up when the power is ON. )
on the emitter.

Operation mode switch


Operation mode switch

FIBER
SENSORS

Description
Light-ON mode is obtained when the
operation mode switch (thru-beam type incorporate it in the receiver ) is turned fully
clockwise (L side).
Dark-ON mode is obtained when the operation mode switch (thru-beam type incorporate it in the receiver ) is turned fully counterclockwise (D side).

LASER
MARKERS

Thru-beam type
1. Set the operation mode switch to the Light-ON mode position (L
side).
2. Place the emitter and the receiver face to face along a straight
line, move the emitter in the up, down, left and right directions, in
order to determine the range of the light received condition with
the help of the operation indicator (orange). Then, set the emitter at the center of this range.
3. Similarly, adjust for up, down, left and right angular movement of
the emitter.
4. Further, perform the angular adjust- Sensing object
ment for the receiver also.
5. C heck that the stability indicator
(green) lights up.
6. Choose the operation mode, LightEmitter
ON or Dark-ON, as per your requirement, with the operation mode
Receiver
switch.

PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS

Selection
Guide

Retroreflective type
1. Set the operation mode switch to the Light-ON mode position (L
side).
2. Placing the sensor and the reflector face to face along a straight
line, move the reflector in the up, down, left and right directions,
in order to determine the range of the light received condition
with the help of the operation indicator (orange). Then, set the
reflector at the center of this range.
3. Similarly, adjust for up, down, left and right angular movement
of the reflector.
4. Further, perform the angular adjustment for the sensor also.
5. Check that the stability indicator
(green) lights up.
Sensing object
6. 
C hoose the operation mode,
Light-ON or Dark-ON, as per your
requirement, with the operation
mode switch.
Reflector
Sensor

Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

297

Compact Photoelectric Sensor

PRECAUTIONS FOR PROPER USE

FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS

Sensitivity adjustment

PRESSURE /
FLOW
SENSORS

PARTICULAR
USE
SENSORS
SENSOR
OPTIONS

A
3

WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS

MACHINE
VISION
SYSTEMS

The position at the middle of points


is the optimum sensing position.

and

Note: Use the flathead screwdriver (purchase separately) to turn the adjuster
slowly. Turning with excessive strength will cause damage to the
adjuster.

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

Light condition
Emitter

Dark condition
Emitter

Receiver

Thru-beam
type

Receiver

Sensing object

UV
CURING
SYSTEMS

Sensor

Reflector

Sensor

Retroreflective
type

Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

Diffuse
reflective
type

Reflector

Sensing object

Sensor

EX-20
EX-30

Operation
indicator

Output

EX-40
CX-440

ON

EQ-30
EQ-500
MQ-W

OFF

RX-LS200
RX
RT-610

: Lights up,

Glossy surface

If a shiny object is covered or wrapped with a transparent


film, such as those described below, the retroreflective type
sensor with polarizing filters may not be able to detect it.
In that case, follow the steps given below.

Can wrapped by clear film


Aluminum sheet covered by plastic film
Gold or silver color (specular) label or wrapping paper
Steps

Tilt the sensor with respect to the sensing object while fitting.
Reduce the sensitivity.
Increase the distance between the sensor and the
sensing object.
CX-48
Retroreflective type sensor for transparent object sensing (CX-48)
Optimum sensing is possible when the position of the
transparent sensing object is set at the center of the
sensor and the reflector. If the sensing position is set
near the sensor or the reflector, the sensing may be
unstable. In this case, set the sensing position at the
center of the sensor and the reflector.

Sensor

In case of Light-ON
Stability
indicator

Reflector

10 to 30

Retroreflective type sensor with polarizing filters (CX-491)

Sensing object

Sensing
condition
Stable light
receiving
Unstable light
receiving
Unstable dark
receiving
Stable dark
receiving

: Turns OFF

Reflector

Transparent sensing object

Relation between output and indicators

EX-10

Sensing
object

Sensor

CX-400
CY-100

Make L sufficiently
long

Example of sensing objects


B

LASER
MARKERS

FA
COMPONENTS

In the dark condition, turn the sensitivity adjuster


further clockwise until the sensor enters the
Light state operation and then bring it back to
confirm point where the sensor just returns to
the Dark state operation.
If the sensor does not enter the Light
state operation even when the sensitivity
adjuster is turned fully clockwise, the
position is point .

Optimum
position

STATIC
ELECTRICITY
PREVENTION
DEVICES

Make L, shown in the


diagram, sufficiently long.
2 Install at an angle of 10 to
30 degrees to the sensing
object.
1

In the light received condition, turn the


sensitivity adjuster slowly clockwise and
confirm the point where the sensor
enters the Light state operation.

SIMPLE
WIRE-SAVING
UNITS

Please take care of the following points when detecting


materials having a gloss.

Description
Turn the sensitivity adjuster fully
counterclockwise to the minimum
sensitivity position, MIN.

INDUCTIVE
PROXIMITY
SENSORS

Retroreflective type sensor (excluding CX-491)

Sensitivity
adjuster

Step

LIGHT
CURTAINS /
SAFETY
COMPONENTS

HUMAN
MACHINE
INTERFACES

Refer to p.1458~ for general precautions.

CX-41CX-42CX-49CX-48

AREA
SENSORS

PLC

CX-400 SERIES Ver.2

In case of Dark-ON
Output

OFF

Operation Stability
indicator
indicator

When the sensor detects an uneven plastic receptacle or


glass bottle, the received-light amount may differ with the
sensing position or direction. Adjust the sensitivity after
confirming the stable sensing condition by turning the
sensing object, etc.
When sensing pipe-shaped transparent sensing object,
set it in a standing, not lying, position as shown in Figure
A. The sensor may fail to detect a lying object as shown
in Figure B.
Correct

Incorrect

ON

Sensor

Reflector

Sensor

Reflector

Compact Photoelectric Sensor

PRECAUTIONS FOR PROPER USE

CX-400 SERIES Ver.2

298

Refer to p.1458~ for general precautions.

FIBER
SENSORS
LASER
SENSORS

CX-41
Slit mask (Optional)

Interference prevention filter (CX-411)

PHOTOELECTRIC
SENSORS

With the slit mask OS-CX-, the sensor can detect a


small object.
However, the sensing range is reduced when the slit
mask is mounted.

By mounting the interference prevention filters PF-CX4-,


two sets of the CX-411 can be mounted close together.
However, the sensing range is reduced when the
interference prevention filter is mounted.

How to mount

The filters can be mounted by the same method as for


the slit masks.

LIGHT
CURTAINS /
SAFETY
COMPONENTS

Since there are two types of the interference prevention


filter, the two sets of sensors should be fitted with
different types of interference prevention filters, as shown
in the figure below.
The interference prevention does not work even if the
filters are mounted for emitters only, receivers only or the
same model No. of the interference prevention filters are
mounted on both the sets of the sensor.

PRESSURE /
FLOW
SENSORS

1. Insert the fixing hook into the fixing groove.


2. Then, pressing the slit mask against the main unit, insert
the fixing tab into the fixing groove.
Fixing groove

Fixing tab

Removing tab

AREA
SENSORS

INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS

PF-CX4-H
(Horizontal, Light brown)

WIRE-SAVING
SYSTEMS

Fixing groove

Slit mask

MICRO
PHOTOELECTRIC
SENSORS

MEASUREMENT
SENSORS

Fixing hook

STATIC
ELECTRICITY
PREVENTION
DEVICES

How to remove

LASER
MARKERS

1. Insert a screwdriver into the removing tab.


2. Pull forward while lifting the removing tab.

PF-CX4-V
(Vertical, Silver)

Correct

Correct

Sensing
object

Sensing
object

Operation mode switch

Sensing
object

FA
COMPONENTS

Description
Detecting-ON mode is obtained when
the operation mode switch is turned fully
clockwise (L side).

Do not make the


sensor detect an
object in this direction
because it may cause
unstable operation.

When detecting a specular object (aluminum or copper


foil, etc.) or an object having a glossy surface or coating,
please take care that there are cases when the object
may not be detected due to a change in angle, wrinkles
on the object surface, etc.
When a specular body is present below the sensor, use the
sensor by tilting it slightly upwards to avoid wrong operation.
Incorrect

Operation mode switch

Incorrect

HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

CX-44
Mounting
Care must be taken regarding the sensor mounting
direction with respect to the objects direction of movement.

PLC

MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS

Not detecting-ON is obtained when the


operation mode switch is turned fully
counterclockwise (D side)
Note: Use the flathead screwdriver (purchase separately) to turn
the operation mode switch slowly. Turning with excessive
strength will cause damage to the adjuster.

Depending on whether you select the BGS or FGS


function, the output operation changes as follows.

Correct

Sensing range

Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

CX-400
CY-100

Setting
distance

EX-10
EX-20

Non-detectable area

EX-30

Specular
face

Tilt

If a specular body is present in the background, wrong operation


may be caused due to a small change in the angle of the
background body. In that case, install the sensor at an inclination
and confirm the operation with the actual sensing object.
Take care that there is a non-detectable area right in front
of the sensor.

L-ON

ON
OFF

D-ON

ON
OFF

EQ-30

L-ON

ON
OFF

MQ-W

D-ON

ON
OFF

BGS

FGS

EX-40
CX-440

EQ-500

RX-LS200
RX
RT-610

299

LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS

PRECAUTIONS FOR PROPER USE

SIMPLE
WIRE-SAVING
UNITS

Stability indicator

When using the BGS function

Since the CX-44 use a 2-segment photodiode as its


receiving element, and sensing is done based on the
difference in the incident beam angle of the reflected
beam from the sensing object, the output and the
operation indicator (orange) operate according to the
object distance.
Further, the stability indicator (green) shows the margin
to the setting distance.
Sensor

Setting distance

STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES

Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

Description

Turn the distance adjuster fully counterclockwise


to the minimum sensing range position.
(CX-441/443/444: 20 mm 0.787 in approx.,
CX-442: 40 mm 1.575 in approx.)

Place an object at the required distance from the


sensor, turn the distance adjuster gradually
clockwise, and find out point A where the sensor
changes to the detecting condition.

Remove the object, turn the adjuster clockwise


further until the sensor goes into the detecting
state again. Once it has entered, turn the
distance adjuster backward until the sensor
returns to the non-detecting condition. This
position is designated as point B . When the
sensor does not go into the detecting condition
even if the adjuster is turned fully clockwise, the
position where the adjuster was fully turned is
regarded as the point B .
There may be more than 1 turn between point
A and B , since this sensor incorporates a
5-turn adjuster.

Stability indicator

The optimum position to stably detect objects is


the center point between A and B .

OFF (Lights off)


Stable operating condition

Lights up

Stable operating condition

Lights off

Unstable operating condition

BGS / FGS functions


This sensor incorporates BGS / FGS functions. Select
either BGS or FGS function depending on the positions of
the background and sensing object.
BGS function

This function is used when the sensing object is


apart from the background.
Sensing
object

FA
COMPONENTS

UV
CURING
SYSTEMS

Step

ON (Lights up)

Output (operation indicator)


(BGS mode, In case of Detection-ON)

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

MACHINE
VISION
SYSTEMS

<When a sensing object is moving right or left to the sensor>

Sensing object

WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS

Refer to p.1458~ for general precautions.

CX-44

PARTICULAR
USE
SENSORS
SENSOR
OPTIONS

CX-400 SERIES Ver.2

Turn fully

Optimum
position

Follow only steps 1 and 2 . Since the sensing point may


change depending on the sensing object, be sure to
check the operation with the actual sensing object.
When using the FGS function

FGS function

This function is used when the


sensing object contacts the
background or the sensing object is
glossy, etc.
Please use the FGS function
together with a conveyor or other
background unit.

Distance
adjuster

<When a sensing object is approaching / moving away from the sensor>

Background

FIBER
SENSORS

Compact Photoelectric Sensor

Please use the FGS function together with a conveyor or other background unit.
Step

Sensing
object

Background

Distance adjustment
When this product is used, be sure to carry
out the distance adjustment.
Since the distance adjuster of this sensor is
a 5-turn adjuster, when the point A and B is
adjusted as explained in the table right, there
may be more than 1 turn between the point A
and B . Therefore, make sure to remember the
turns of both points to find the optimum position.
Be sure to wire the sensing mode selection
input (Pink / 2) before distance adjustment.
If the wiring is done after the distance
adjustment, the sensing area is changed.
Turn the distance adjuster gradually and lightly with a
minus screwdriver (purchase separately). In order to
protect itself, the distance adjuster idles if turned fully.
If the adjuster is idled when distance adjustment is done,
carry out the adjustment again.

Description
Turn the distance adjuster fully clockwise to the
maximum sensing range position.
(CX-441/443: 50 mm 1.969 in approx.,
CX-444: 100 mm 3.937 in approx.,
CX-442: 300 mm 11.811 in approx.)
In the state where the sensor detects the
background, turn the distance adjuster gradually
counterclockwise, and find out point A where
the sensor changes to the non-detecting
condition.

Place an object at the required distance from the


sensor, turn the adjuster counterclockwise further
until the sensor goes into the non-detecting
condition again. Once entered, turn the distance
adjuster backward until the sensor returns to the
detecting condition. This position is designated
as point B . When the sensor does not go into
the non-detecting condition even if the adjuster is
turned fully counterclockwise, the position where
the adjuster was fully turned is regarded as the
point B .
There may be more than 1 turn between point
A and B , since this sensor incorporates a
5-turn adjuster.

The optimum position to stably detect objects is


the center point between A and B .

Distance
adjuster

Turn fully

Optimum
position

Others
Its distance adjuster is mechanically operated. Do not
drop; avoid other shocks.

Compact Photoelectric Sensor

DIMENSIONS (Unit: mm in)


Sensor

Operation indicator (Orange)(Note 2)

Beam
axis

Operation mode switch (Note 1)


20
0.787
3
0.118

3.7 0.146 cable,


2 m 6.562 ft long (Note 4)
3-core (emitter: 2-core) 0.2 mm2
insulator diameter: 1.2 0.047

Notes: 1) Not incorporated on the emitter and the basic type sensor.

2) It is the power indicator (green) on the emitter.

3) Not incorporated on the emitter.

4) Basic type: 0.5 m 1.640 ft long

CX-41-J

Sensor

Sensitivity adjuster (Note 1)


Operation indicator (Orange)(Note 2)

Stability indicator (Green)(Note 1)

Beam
axis

Operation indicator (Orange)

2-M3 0.5 0.020


thru-hole threads
3.7 0.146 cable

SENSOR
OPTIONS

M8 connector

11.8
0.465

WIRE-SAVING
SYSTEMS

Center of
sensing

2-M3 0.5 0.020


thru-hole threads

HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS

2.3
(0.091
)

15.5 0.610
25.4
31
1.220 1.000

4
0.157
Beam-emitting
part

PLC

20
0.787
3
0.118

11.2
0.441

STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS

7.85 0.309
3.95 0.156

Operation mode switch (Note 1)

MACHINE
VISION
SYSTEMS

3.7 0.146 cable,


2 m 6.562 ft long (Note 2)

UV
CURING
SYSTEMS

3-core 0.2 mm2


insulator diameter: 1.2 0.047

300
(11.811
)

Notes: 1) Not incorporated on the emitter.



2) It is the power indicator (green) on the emitter.

SIMPLE
WIRE-SAVING
UNITS

Sensor

Stability indicator (Green)

4 0.157

) M12 connector
44
(1.732
)

PARTICULAR
USE
SENSORS

CX-49CX-48CX-42

Beam-receiving
part
2.3
0.091

INDUCTIVE
PROXIMITY
SENSORS

MEASUREMENT
SENSORS

Operation mode switch (Note 1)

15.5 0.610
31
25.4
1.220 1.000

PRESSURE /
FLOW
SENSORS

Notes: 1) Not incorporated on the emitter.



2) It is the power indicator (green) on the emitter.

7.85 0.309
3.95 0.156

20
0.787
3
0.118

11.2
0.441

LIGHT
CURTAINS /
SAFETY
COMPONENTS

2.3
( 0.091
)

2-M3 0.5 0.020


thru-hole threads

Sensitivity adjuster (Note 1)

11.8
0.465

AREA
SENSORS

15.5
31 0.610 25.4
1.220 1.000
35.5
1.398
42.5
1.673

9.4
0.370

LASER
SENSORS

MICRO
PHOTOELECTRIC
SENSORS

7.85 0.309
3.95 0.156

20
0.787
3
0.118

Beam
axis

FIBER
SENSORS

PHOTOELECTRIC
SENSORS

Operation mode switch (Note 1)


11.2
0.441

2-M3 0.5 0.020


thru-hole threads

11.8
0.465

Stability indicator (Green)(Note 1)

2.3
(0.091
)

15.5 0.610
25.4
31
1.220 1.000

Sensor

Operation indicator (Orange)(Note 2)

7.85 0.309
3.95 0.156

Stability indicator (Green)(Note 3)


11.2
0.441

CX-41-Z
Sensitivity adjuster (Note 1)

11.8
0.465

300

The CAD data in the dimensions can be downloaded from our website.

CX-41
Sensitivity adjuster (Note 1)

CX-400 SERIES Ver.2

Notes: 1) Not incorporated on the Bacic type sensors.



2) Basic type: 0.5 m 1.640 ft long
Selection
Guide

CX-49-ZCX-48-ZCX-42-Z
Sensitivity adjuster
Operation indicator (Orange)

Stability indicator (Green)

15.5 0.610
25.4
35.5 31
1.220
42.5 1.398
1.000
1.673

9.4
0.370

11.8
0.465

2-M3 0.5 0.020


thru-hole threads

CX-49-JCX-48-JCX-42-J
Sensitivity adjuster

7.85 0.309
3.95 0.156

Operation indicator (Orange)

Operation mode switch


20
0.787
3
0.118

11.2
Beam-receiving 0.441
part
Center of
sensing

4
4 0.157
0.157
Beam-emitting
part

Sensor

Stability indicator (Green)


11.2
Beam-receiving 0.441
part
4 0.157

2.3
( 0.091
)

M8 connector

4
0.157
Beam-emitting
part

Center of
sensing

15.5 0.610
31
25.4
1.220 1.000

2-M3 0.5 0.020


thru-hole threads

Sensor

Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

11.8
0.465

7.85 0.309
3.95 0.156

CX-400

Operation mode switch


20
0.787
3
0.118

CY-100
EX-10
EX-20
EX-30

2.3
0.091 M12 connector

44
(1.732
)

3.7 0.146 cable


300
(11.811
)

EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

301
FIBER
SENSORS
LASER
SENSORS

Compact Photoelectric Sensor

CX-400 SERIES Ver.2

DIMENSIONS (Unit: mm in)


CX-44

MICRO
PHOTOELECTRIC
SENSORS

12.5
0.492

Operation indicator (Orange)


Distance adjuster (5-turn)

AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS

Stability indicator (Green)


11.2
0.441

PRESSURE /
FLOW
SENSORS

PARTICULAR
USE
SENSORS

Beamreceiving part

22
0.866
Beamemitting part

Center of
sensing

2
0.079 2.8
0.110

HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

31 25.4
1.220 1.000

22
0.866
Center of
sensing

3.7 0.146 cable,


2 m 6.562 ft long
4-core 0.2mm2
insulator diameter:
1.2 0.047

Beamreceiving part

9.4
0.370

RF-220

0.9
0.035

31 25.4
35.5
42.5 1.398 1.220 1.000
1.673
Beamemitting part

M8 connector

2-M3 0.5 0.020


thru-hole threads

RF-210

Reflector (Optional)

Reflector (Optional)
33.3
1.311

12.8 0.504

35.3
1.390

M3 nut mounting holes


(for mounting at the back)

Reflector

49.3
59.3 1.941
2.335

2-3.6 0.142
mounting
holes

25
0.984

8.3
0.327

2-4.6 0.181
mounting
holes

3.2
0.126

4 0.157

3.3
0.130

40
1.575

Material: Acrylic (Reflector)


ABS (Base)

21
( 0.827
)

8 0.315

5 0.197

MACHINE
VISION
SYSTEMS

11 0.433

34.3
42.31.350
1.665

30
(1.181
)

10 0.394

8.2
0.323
4
0.157
Operation mode switch

20
0.787
3 0.118

2 2.8
0.079 0.110

50.3
1.980

FA
COMPONENTS

UV
CURING
SYSTEMS

Distance adjuster (5-turn)

0.9
0.035

LASER
MARKERS
PLC

12.5
0.492

Operation indicator (Orange)

11.2
0.441

RF-230 Reflector (Accessory for the retroreflective type sensor)

STATIC
ELECTRICITY
PREVENTION
DEVICES

Sensor

Stability indicator (Green)

SIMPLE
WIRE-SAVING
UNITS

MEASUREMENT
SENSORS

8.2
0.323
4
0.157
Operation mode switch

20
0.787
3 0.118

2-M3 0.5 0.020


thru-hole threads

SENSOR
OPTIONS

WIRE-SAVING
SYSTEMS

CX-44-Z

Sensor

PHOTOELECTRIC
SENSORS

INDUCTIVE
PROXIMITY
SENSORS

The CAD data in the dimensions can be downloaded from our website.

3.3
0.130

Base
2-3.4 0.134 thru-holes
(for mounting at the side)

25
0.984
10
0.394

2-3.4 0.134 holes,


6 0.236 deep
(for mounting at the back)

8.3
0.327
2-M3 nut mounting holes
(for mounting at the side)

Material: A
 crylic (Reflector)
ABS (Base)
Material: Acrylic (Reflector)
ABS (Base)

Two M3 (length 8 mm 0.315 in)


screws with washers and two nuts are attached.

Note: It is not attached with the basic type sensor.

Selection
Guide
Amplifier
Built-in

RF-11

Power Supply
Built-in

30
1.181
28
1.102

Amplifierseparated

CX-400

RF-12

Reflective tape (Optional)


30
1.181
28
1.102

0.7
0.028

0.7
0.028

Adhesive
tape

23
25
0.984 0.906

EX-30

CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

0.5
0.020

Reflective surface
(Acrylic)

EX-20

EX-40

30
1.181

Reflective tape (Optional)

Rear surface

Effective
reflecting surface
Material: Acrylic

RF-13

30
1.181

( )

8
6
0.315 0.236

CY-100
EX-10

Reflective tape (Optional)

Effective
reflecting surface
Material: Flexible polyvinyl chloride

Adhesive
tape

( pressure-sensitive
)
adhesive

Compact Photoelectric Sensor

DIMENSIONS (Unit: mm in)

CX-400 SERIES Ver.2

The CAD data in the dimensions can be downloaded from our website.

MS-CX2-1

Sensor mounting bracket (Optional)


5
0.197
3.4
0.134
14 0.551

Assembly dimensions

12
0.472
3
0.118
R12
R0.472

8 0.315

22
0.866
15
0.591
7

t 1.2
t 0.047

0.5
0.020

Mounting drawing with the


receiver of CX-41

3.4
0.134

3.4
0.134

2-3.4 0.134 holes


(for RF-210)

R12 R0.472

12
0.472

3
0.118
5
0.197

22
0.866

10 0.394

0.3
(0.012
)

25.4
1.000

31
1.220
25
0.984

Material: Stainless steel (SUS304)

9.5
0.374

Two M3 (length 12 mm 0.472 in) screws with washers are attached.

42.5
1.673
t 1.2
t 0.047

12.3 0.484

Sensor mounting bracket (Optional)

15.8
0.622

7
0.276
7.8
0.307

22 0.866
14
0.551

R12 R0.472

14

12
0.472

3.6
(0.142
)

15.8
0.622
8.2
0.323

4
0.157

Beam axis

23
15.5
0.906 0.610

36
1.417

55
2.165

28
1.102

4.5
0.177
5 0.197

14
4.5
0.177

4 0.157
4.5 0.177

t2
t 0.079

4
0.157

R12 R0.472

12
0.472

4.5 0.177

FA
COMPONENTS

15.5
0.610

MACHINE
VISION
SYSTEMS

7 0.276
4.5
0.177
5 0.197

8.2 0.323

0.9
0.035

0.9
0.035

13
0.512

t 2.5
t 0.098
Two M3 (length 14 mm 0.551 in) screws with washers are attached.
Material: Stainless steel (SUS304)

CY-100
29
1.142

6.2
0.244

46
1.811

Power Supply
Built-in

EX-10
EX-20

5.5
0.217 5.5
0.217

25
0.984

Amplifier
Built-in

CX-400

R9.5
R0.374

EX-30

18
0.709
13
0.512 11.2
0.441

EX-40
CX-440
EQ-30
EQ-500

25.4
1.000
12.3 0.484
Beam axis

46
1.811
25
0.984
t 2.5
t 0.098

SENSOR

25 0.984
R25
R0.984

4
0.157
3.4
0.134

UV
CURING
SYSTEMS

Amplifierseparated

4020

SENSOR

25
0.984

SENSOR

25
0.984

25.4
1.000

55 2.165
39 1.535
7
0.276

Mounting drawing
with the receiver
of CX-41

19
29
0.748 1.142

SENSOR

3.4
0.134

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

Assembly dimensions

55 2.165
39 1.535
6
0.236

14

MEASUREMENT
SENSORS

HUMAN
MACHINE
INTERFACES

Sensor mounting bracket (Optional)

18
0.709

SIMPLE
WIRE-SAVING
UNITS

Selection
Guide

MS-CX2-4

19
0.748

SENSOR
OPTIONS

PLC

22
0.866
14
0.551

Two M3 (length 12 mm 0.472 in) screws with washers are attached.

7
0.276

INDUCTIVE
PROXIMITY
SENSORS

LASER
MARKERS

Material: Stainless steel (SUS304)

20

PRESSURE /
FLOW
SENSORS

Mounting drawing with the


receiver of CX-41

7.8
0.307

40

LIGHT
CURTAINS /
SAFETY
COMPONENTS

STATIC
ELECTRICITY
PREVENTION
DEVICES

8-3.4 0.134
holes

7 0.276

4.5
0.177

t2
t 0.079

AREA
SENSORS

Assembly dimensions

25
10
0.394 0.984

55
2.165

MICRO
PHOTOELECTRIC
SENSORS

WIRE-SAVING
SYSTEMS

MS-CX2-2
14
0.551

LASER
SENSORS

PARTICULAR
USE
SENSORS

Beam axis

20
0.787

12.5 0.492

36
1.417

3.4
0.134 13.6 0.535 25.2
0.992

14

FIBER
SENSORS

PHOTOELECTRIC
SENSORS

20
0.787

14

3.4
25 0.134 R25
42.5 0.984
R0.984
1.673

302

MQ-W
RX-LS200
RX
RT-610

303
FIBER
SENSORS
LASER
SENSORS

Compact Photoelectric Sensor

CX-400 SERIES Ver.2

DIMENSIONS (Unit: mm in)


MS-CX2-5

Sensor mounting bracket (Optional)

PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS

15
0.591

AREA
SENSORS

t 1.5
t 0.059

LIGHT
CURTAINS /
SAFETY
COMPONENTS

3.4
0.134
3.4
0.134

3.5
0.138

SENSOR
OPTIONS

5
0.197

SIMPLE
WIRE-SAVING
UNITS

STATIC
ELECTRICITY
PREVENTION
DEVICES

8
0.315

Amplifierseparated

CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

20
0.787
37
1.457

5
0.197
7.9 0.311

MS-CX-3

Sensor mounting bracket (Optional)

Assembly dimensions

t 1.2
t 0.047

30 1.181
20.5
0.807
10
R25
R0.984

3.5
0.138 5
3.4
0.197
0.134
3.4
0.134

14
0.551
8
3.4
0.315
0.134
6
0.236

35
25
0.984 1.378

25.2
0.992
13.6
0.535
11.2
0.441

18
0.709
Beam axis

R25
R0.984

10

15
0.591

3.4
0.134
5
0.197

6
0.236

0.5
0.020

Mounting drawing with the


receiver of CX-41

8.5
0.335

Two M3 (length 12 mm 0.472 in) screws with washers are attached.

Amplifier
Built-in

7
0.276

20
7 0.787
0.276 37
1.457

Material: Stainless steel (SUS304)

Power Supply
Built-in

R25
R0.984

45
1.772

Two M3 (length 12 mm 0.472 in) screws with washers are attached.

MACHINE
VISION
SYSTEMS

Selection
Guide

Beam axis

Material: Stainless steel (SUS304)

FA
COMPONENTS

UV
CURING
SYSTEMS

25.4
1.000

18.9
0.744 5 0.197
6.5 0.256

PLC

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

t 1.5
t 0.059

7.9
0.311

LASER
MARKERS

HUMAN
MACHINE
INTERFACES

15
0.591

20.6
26.2 0.811
1.031

18.9
0.744 5 0.197
6.5 0.256

PARTICULAR
USE
SENSORS

MEASUREMENT
SENSORS

Mounting drawing with the


receiver of CX-41

R19
R 0.748
R25
R0.984

45
1.772

INDUCTIVE
PROXIMITY
SENSORS

Assembly dimensions

25
0.984
19
0.748
19
0.748

PRESSURE /
FLOW
SENSORS

WIRE-SAVING
SYSTEMS

The CAD data in the dimensions can be downloaded from our website.

6
0.236

3.5
0.138
4.8
0.189

18
0.709

6 0.236
3.4
0.134

8
0.315
14
0.551

30
1.181
10

t 1.2
t 0.047
0.4
0.016

8.5
0.335

9 0.354

31
1.220

20
0.787

25.4
1.000

35
1.378

Compact Photoelectric Sensor

DIMENSIONS (Unit: mm in)

CX-400 SERIES Ver.2

The CAD data in the dimensions can be downloaded from our website.

MS-RF21-1

Reflector mounting bracket for RF-210 (Optional)


23
0.906

5.5
0.217

23
0.906

36
50
1.417 1.969

30

10
0.394
3.2
0.126
25
t 1.2 0.984
t 0.047
12.5 0.492

10
0.394

R7.5
R0.295

46
1.811
25
0.984

PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS

20

PARTICULAR
USE
SENSORS

46
1.811

SENSOR
OPTIONS

25
0.984

13
0.512

SIMPLE
WIRE-SAVING
UNITS

13
0.512

WIRE-SAVING
SYSTEMS

Material: Stainless steel (SUS304)


Two M3 (length 12 mm 0.472 in) screws with washers are attached.

MS-RF22

Reflector mounting bracket for RF-220 (Optional)

Assembly dimensions

25
0.984
4.5
0.177

35
1.378
25
0.984

28.3
19.3 1.114
0.760

4
0.157

35.3
1.390

HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

8.3
0.327

FA
COMPONENTS

16 0.630

8 0.315
6 0.236
8-M3 0.5 0.020
thru-hole threads

44.3
1.744

t 1.6
t 0.063

MACHINE
VISION
SYSTEMS

34.3
1.350

21
( 0.827
)

27
(1.063
)

20
0.787

STATIC
ELECTRICITY
PREVENTION
DEVICES

PLC

10
0.394

11
0.433
10
0.394

MEASUREMENT
SENSORS

LASER
MARKERS

25
0.984

4.5
0.177

44
10 0.394 1.732

AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS

30

3.5
0.138

LASER
SENSORS

MICRO
PHOTOELECTRIC
SENSORS

36
50
1.417 1.969

20
16
0.630

FIBER
SENSORS

PHOTOELECTRIC
SENSORS

Assembly dimensions
5.5
0.217

304

8 0.315

t 1.6
t 0.063

UV
CURING
SYSTEMS

4
0.157

6
0.236

Material: Cold rolled carbon steel (SPCC)


(Uni-chrome plated)
Two M3 (length 8 mm 0.315 in) screws with washers are attached.
Selection
Guide

MS-RF23

Reflector mounting bracket for RF-230 (Optional)


40
1.575

3
(0.118
)

Power Supply
Built-in

Assembly dimensions
4.5
0.177

4.5
0.177

10
0.394 11
0.433

CX-400
28.3
19.3 1.114
0.760
50.3
1.980

5 0.197

Amplifierseparated

40
1.575

10
0.394

50
1.969
40
1.575

CY-100
EX-10

8.3
0.327

EX-20
EX-30

16 0.630

18 0.709
12
0.472
3
(0.118
)

EX-40

15 0.591 61
2.402

35
1.378

t2
t 0.079

7 0.276
26
1.024
28
1.102

20
0.787
8-M4 0.7 0.028 thru-hole threads

Material: Cold rolled carbon steel (SPCC)


(Uni-chrome plated)
Two M4 (length 10 mm 0.394 in) screws with washers are attached.

Amplifier
Built-in

30
(1.181
)

7
0.276

CX-440

49.3
1.941

61.3
2.413
37
1.457

10
0.394
40
1.575

5
0.197

EQ-30
t2
t 0.079

EQ-500
MQ-W
RX-LS200
RX
RT-610

305
FIBER
SENSORS
LASER
SENSORS

Compact Photoelectric Sensor

DIMENSIONS (Unit: mm in)


MS-AJ1

PHOTOELECTRIC
SENSORS

17.8
0.701 12
2-3.4 0.134
0.472
mounting holes
t2
2-3.2
0.1264.2 0.165
t 0.079
oblong holes
1 0.039

Cable guide
(POM)

AREA
SENSORS

Cable guide
(POM)

45

17.8
0.701 12
2-3.4 0.134
0.472 mounting holes
t2
2-3.2
0.1264.2 0.165
t 0.079
oblong holes
1 0.039

Attachment
(Nylon 6)

SIMPLE
WIRE-SAVING
UNITS

44.5
(1.752
) 28

20
0.787
45
1.772

STATIC
ELECTRICITY
PREVENTION
DEVICES

36.5
(1.437
)

18
0.709

1.102

WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS

8
0.315

Base
(PA)

Two M3 (length 14 mm 0.551 in) screws


with washers, two M3 (length 16 mm
0.630 in) screws with washers, two M3
(length 18 mm 0.709 in) screws with
washers, one auxiliary mounting plate for
EQ-20 series and one auxiliary mounting
plate for EX-40 series are attached.

25.5
1.004
32
10
1.260
0.394
2-6.6 0.260 mounting holes

1
20
0.787 0.039

45
4.2 0.165
M4 hexagonsocket-head
bolt

10 0.394 pipe
[Stainless steel (SUS304)]

PARTICULAR
USE
SENSORS
SENSOR
OPTIONS

45

3.2
0.126

Sensor mounting bracket


[Stainless steel (SUS304)]

147
(5.787
)(Note)
210
(8.268)

10 0.394 pipe
[Stainless steel (SUS304)]

28 20
1.102 0.787
4
0.157

25 20
33
1.299 0.984 0.787

45
4.2 0.165
M4 hexagonsocket-head
bolt

Sensor mounting bracket


[Stainless steel (SUS304)]

147
(5.787
) (Note)
218
(8.583)

Universal sensor mounting stand (Optional)

11.8
0.465
20 0.787
6 0.236

3.2
0.126
1
0.039

Attachment
(Nylon 6)

MS-AJ2

28 20
1.102 0.787
4
0.157

33 25 20 20
1.299 0.984 0.7870.787

LIGHT
CURTAINS /
SAFETY
COMPONENTS

INDUCTIVE
PROXIMITY
SENSORS

The CAD data in the dimensions can be downloaded from the website.

Universal sensor mounting stand (Optional)

11.8
0.465
20 0.787
6 0.236

MICRO
PHOTOELECTRIC
SENSORS

PRESSURE /
FLOW
SENSORS

CX-400 SERIES Ver.2

2-6.6 0.260
mounting holes
20
0.787

10
0.394
24.5
0.965

Base
(PA)

32
1.260
46
1.811
20
0.787

Two M3 (length 14 mm 0.551 in) screws


with washers, two M3 (length 16 mm
0.630 in) screws with washers, two M3
(length 18 mm 0.709 in) screws with
washers, one auxiliary mounting plate for
EQ-20 series and one auxiliary mounting
plate for EX-40 series are attached.

31
1.220
15
8
0.591 0.315

LASER
MARKERS

Note: The dimensions in the brackets indicate the adjustable range of the
movable part.

Note: The dimensions in the brackets indicate the adjustable range of the
movable part.

PLC

Assembly dimensions with CX-400 series (Mounting part only)

Assembly dimensions with RF-210 (Reflector) (Mounting part only)

HUMAN
MACHINE
INTERFACES

23.2
0.913

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

11.8
0.465
20
0.787 6
0.236

FA
COMPONENTS

2-M3 (length14 mm 0.551 in)


screws with washers
Center of sensing

UV
CURING
SYSTEMS

MS-AJ1-A
16.5
0.650

Selection
Guide

Power Supply
Built-in

28.45
1.120

6 0.236
Cable guide
(POM)

210
8.268

4.2 10 0.394 pipe


0.165 [Stainless steel (SUS304)]

218
(8.583
)

EX-40

8
0.315

CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

( )

28
1.102

20
0.787
45
1.772

25.5
1.004
32
10
1.260
0.394
2-6.6 0.260 mounting holes

MS-AJ2-A
16.5
0.650

16.5
0.650

33
1.299

28.45
1.120

Cable guide
(POM)

Base
(PA)

20
0.787

Two M3 (length 14 mm 0.551 in) screws


with washers, two M3 (length 16 mm
0.630 in) screws with washers, two M3
(length 18 mm 0.709 in) screws with
washers, one auxiliary mounting plate for
EQ-20 series and one auxiliary mounting
plate for EX-40 series are attached.

Notes: 1) The dimensions in the brackets indicate the adjustable range of the movable part.
2) Refer to MS-AJ1 / MS-AJ2 for the assembly dimensions with the
sensor mounting bracket, sensor or reflector.

31
1.220
8
15
0.591 0.315

210
8.268
134
5.276 (Note 1)
4.2 10 0.394 pipe
0.165 [Stainless steel (SUS304)]

12
0.472

33
(1.299
)

10
0.394

36.5
(1.437
)
32
1.260
46
1.811
20
0.787

16.5
(0.650
)
33
1.299

Sensor mounting bracket


[Stainless steel (SUS304)]
(Note 2)
Arm joint
(Nylon 6)
147
2-3.4
0.134
5.787
mounting holes 10 0.394 pipe
(Note 1)
[Stainless steel (SUS304)]
2-3.2 0.1264.2 0.165
oblong holes

210
(8.268
)

(203.5
8.012)
Base
(PA)

45

Universal sensor mounting stand (Optional)

6 0.236

18
0.709

44.5
1.752

45

33
1.299

4.2
0.165
2-M3 (length14 mm 0.551 in)
screws with washers

EX-10

EX-30

( )

Sensor mounting bracket


[Stainless steel (SUS304)]
(Note 2)
Arm joint
(Nylon 6)
147
2-3.4 0.134
5.787
mounting holes
10 0.394 pipe
(Note 1)
[Stainless steel (SUS304)]
2-3.2 0.1264.2 0.165
oblong holes

CY-100

EX-20

45

33
1.299

31.8 20
1.252 0.787

33.3 25
1.311 0.984

4.2
0.165

(134
5.276) (Note 1)

12
0.472

24.8
0.976 18.4
0.724
t2
t 0.079

45

Universal sensor mounting stand (Optional)

Amplifierseparated

CX-400

20
28
1.102 0.787
27
1.063

33 25.4
1.299 1.000

MACHINE
VISION
SYSTEMS

Amplifier
Built-in

17.6
0.693
t2
t 0.079

11.8
0.465
20
0.787 6
0.236

2-6.6 0.260
mounting holes

(208.5
8.209)

24.5
0.965

Two M3 (length 14 mm 0.551 in) screws with


washers, two M3 (length 16 mm 0.630 in) screws
with washers, two M3 (length 18 mm 0.709 in)
screws with washers, one auxiliary mounting
plate for EQ-20 series and one auxiliary mounting
plate for EX-40 series are attached.

Notes: 1) The dimensions in the brackets indicate the adjustable range of the movable part.
2) Refer to MS-AJ1 / MS-AJ2 for the assembly dimensions with the
sensor mounting bracket, sensor or reflector.

Compact Photoelectric Sensor

DIMENSIONS (Unit: mm in)


MS-AJ1-M

22
0.866
2-M4
2-M3

17
0.669

Attachment
(Nylon 6)

)(

208
8.189

147
5.787 (Note)

20
0.787
45
1.772

22
0.866

17
0.669

45
45
4.2
0.165
28
1.102

20
0.787

143.5 (Note)
200 ( 5.650 )
( 7.874
)

8
0.315
Two M3 (length 8 mm 0.315 in)
screws with washers and two M4
(length 8 mm 0.315 in) screws
with washers are attached.

32
10
0.394 1.260
2-6.6 0.260 mounting holes

28
1.102

4.2
0.165

45
45

AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS

20
0.787

PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS

2-6.6 0.260
mounting holes

32
1.260
46
1.811
20
0.787

PARTICULAR
USE
SENSORS

10
0.394

SENSOR
OPTIONS

24.5
0.965

Base
(PA)

Two M3 (length 8 mm 0.315 in)


screws with washers and two M4
(length 8 mm 0.315 in) screws
with washers are attached.

31
1.220
15
8
0.591 0.315

Note: The dimensions in the brackets indicate the adjustable range of the
movable part.

Note: The dimensions in the brackets indicate the adjustable range of the
movable part.

Assembly dimensions with RF-220 (Reflector)


(Mounting part only)

Assembly dimensions with RF-230 (Reflector)


(Mounting part only)

11.8
0.465
20
0.787

55.3
2.177
38
1.496
12
0.472

50
1.969

2-M3 (length 8 mm 0.315 in)


screws with washers

M4 hexagon-sockethead bolt
t2
t 0.079
45

35.3
1.390
28
1.102
45.3
1.783

11.8
0.465

71.3
2.807
47
1.850
20
0.787

4.2
28
0.165
1.102
36.3 20
1.429 0.787

2-M4 (length 8 mm 0.315 in)


screws with washers

37
1.457
61.3
2.413

SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC

M4 hexagon-sockethead bolt

HUMAN
MACHINE
INTERFACES

t2
t 0.079

ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS

45

50.3
1.980

45

LASER
SENSORS

MICRO
PHOTOELECTRIC
SENSORS

10 0.394 pipe
[Stainless steel (SUS304)]

( )

40
1.575 20
0.787

18
0.709

25.5
1.004

Attachment
(Nylon 6)

FIBER
SENSORS

PHOTOELECTRIC
SENSORS

M4 hexagon2-M4 socket-head bolt


t 2 t 0.079
2-M3

25
50
40
0.984 1.575 1.969

Base
(PA)

1.102

Universal sensor mounting stand (Optional)

11.8
0.465

10 0.394 pipe
[Stainless steel (SUS304)]

44.5
(1.752
) 28

MS-AJ2-M

M4 hexagonsocket-head bolt
t 2 t 0.079

40
25
50
0.984 1.575 1.969

306

The CAD data in the dimensions can be downloaded from the website.

Universal sensor mounting stand (Optional)

11.8
0.465

CX-400 SERIES Ver.2

4.2
28
1.102 0.165
36.3 20
1.429 0.787

45

FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS

Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated

CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610

Anda mungkin juga menyukai