a t+ PERTAMINA @ Sesesc APPLICATION FOR INSPECTION Client RFCC Site Construction Manager Project RFCC Cilacap PROJECT Gentlemen, We would like to have your presence for the following inspection(: 21: 101830 GIAFVCVIPIUOO18 Date Job No, AFI No. DATE TIME INSPECTION ITEM PLACE |_ PRESENCE REQUIRED ‘ADHI-GSEC | PERTAMINA 2eNov-i2| 13:00 | "Adhimix Spun Pile Bending Test Ts Mir Bram — [Wir Didik (28 days concrete strength) ‘Surabaya Result [77] Accepted Rejected Re-inspection Required Yes VE JNo Remark PREPARED BY, REVIEWED BY, ew Subcontractor! Construction ADHI-GS E&C. HS Lee APPROVED BY, we bbl PERTAMINA REPORT OF TEST SPUN PILE TESTING © 400 x 7m. RESID FLUID CATALYTIC CRACKING PT. ADHIMIX PRECAST INDONESIA (NOPEMBER 2012) LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 599425155 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email: lppm@its.acid ; wwwlppmits.ac.id KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN . INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-5S Ext, 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.ac.id Nomor 2 me prT2.7/PM/2012 Surabaya, 29 Nopember 2012 Lampiran —_: Laporan Hasil Pengetesan Perihal Pengantar Laporan Hasil Pengetesan Kepada Yih. Kepala Plant PT. Adhimix Precast Indonesia Plant Precast Cilacap ‘Sehubungan dengan permintaan PT. Adhimix Precast Indonesia alamat Plant Precast Cilacap melalui surat nomor : 051/plant clep-adm-pet/X1/2012 tertanggal 26 Nopember 2012 perihal Permohonan Pengujian Material Spun Pile @400 L~ 7000 mm, berdasarkan Surat Perintah Kerja Nomor : 002/proc-api/cilacap/X1/2012, maka bersama ini kami beritahukan bahwa kami telah selesai melakukan pengetesan tethadap material tersebut. Hasil pengetesan ini berupa Buku Laporan Pengetesan seperti pada lampiran, Demikian atas perhatiannya dan kerjasamanya kami sampaikan terima kasih. By NIP. 19600303 198701 1 0( ‘Tembusan 1. Pertinggal KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN , INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKA'T (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.ac.id 1, PURPOSE As per the letter of the PT. Adhimix Precast Indonesia November 26" 2012 to the Civil Engineering Structures Laboratory FTSP - ITS for testing Spun Pile @ 400 L - 7 m, the test was conducted on November 28" 2012. Purpose of this test was to determine the magnitude of the load moment and the moment of ultimate crack that can bear Pile, Testing is done by providing bending loads and deflections recording each specific load and assisted with a Dial Gauge. Thus the flexural behavior of the specimen can be observed. A complete experimental results presented in this report in tabular form, making it easier reading, To clarify the description of the test, the test also included some pictures in this report. 2, SPECIFICATION OF THE TEST OBJECT. * Dimension 0.400 mm + Lenght : 7 m (measurements in the field) © Weight (q) 199 kg/m * Age of concrete 28 day © Meas Teoritical —: 7500 kgm 3. STANDARD TEST Loading position on PC Spun Pile Testing P Ls 3/5L <- US _y, KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN | INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : lppm@its.ac.id ; www.lppm.its.ac.id 4, TEST METHODS ‘Tests based on the standard JIS A 5335-1987. Expenses are given step by step, starting from P = 0 kg, Every step of loading a multiple load 1000 kg. ‘Support = SSS “Loading seheme as = Bending Moment Il [D Pp duc to own weight SS = oe Bending Moment Mn dive to point Lond P ‘The Relationship load and bending moment : xen 5 Where M:: Bending moment (kgm) W : Weight of Pile (ke) L : Length of PC Pile (m) P : Load ( kg) KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 ‘Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@iits.ac.id ; www.lppm.its.accid 5. TEST PROCEDURE No. STEPS SKETCH ] 1 | Preparing the pile to be tested, and | check if there are crack before testing 2 | The Pile is put at horizontal position in simply supporting system. [= 3° | Installing the hydraulic jack in the frame testing, and loading on the pile. The axis of hydraulic jack must are —= be exactly the same as the frame = a testing axis. 4 |The dial gauges (DG) are located below the pile as shown in the figure. This dial gauge is for é measuring deflection on each 5 oo loading step. adi mle mls 5_| Set up the machine conformed with the maximum load will be used. 6 Preparing the test by following testing form enclosed. Continuing loading until pile theoritical Perack KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN | INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.ac.id 6, TESTING RESULT > Place of test > Date of test STRUCTURAL LABORATORY Faculty of Civil Engineering and Planning Depart. Of Civil Engineering ITS Surabaya November 28" 2012 Tabel 1. Results Dial Gauge readings Sample I SAMPLEI 9400-7m Load (P) Result Dial T Dial 2 Dial3 kg mom mm mm 0 | 0.00 0.00 0.0 Too | 061 | 065 [0.70 2000 | LIS. 112 1.27 3000 | 1.63 164 _|_1.77 4000 | 208 | 212 | 223 3000 | 254 | 260 | 2.70 000 | 300 | 309 | 310 6500 | 3.24 333 3.40 7000 | 3.47 | 359 | 365 7500_| 3.70 | 389 | 3.87 3000 | 393 | 408 | 4.10 500 | 420 | 437 | 436 00 [44s | 463 | 401 9500_| 470 490 4.88 10000 | 4.99 522 5.15 10500 | 5.42 5.69 5.55) 11000 | 5.90 622 6.05 11500 | 6.43 681 659 12000 | 7.23 770 737 12500 | 814 3870 8.27 13000 | 894 956 9.10 13500 | 9.90 10.62 | 10.10 igooo | io | 1189 | 11.18 KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN | INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext, 11113, 1121, 1273) Fax. (031) 5996670 Email : lppm@its.ac.id ; www.lppm.its.ac.id Load - Deflection Curve 2.00 200 400 600 809 1000 1200 1400 Deflection & (rm) Gambar 1. Load Deflection Graph of sample I KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN | INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.ac.id ‘Tabel 2. Results Dial Gauge readings Sample II SAMPLE II 400-7 m Toad (P)| Result Diall | Dial2 | Dial3 x mm_|_mm_| mm o | 000 [000 | 0.00 1000] 0.60 | 068 | 0.70 2000 | 1.12 123 1.21 3000 | _1.60_| 177, 175) 4000 [209 [229 | 225 3000 | _2.50_| 277 | 2.70 000 | 3.02 | 329 | 3.20 7900_| _3.50__| 380 | 3.65 8000 | 397 | 433 | 410 3500_[ 43 | 458 | 440 00 | 450 [ 490 | 470 50 [467 | 510 | 487 9500 | 4.98 5.40 5.10 10000 | 538 | 589 | 5.50 10500 | 595 | 650 | 610 t1000_| 659 | 721 6.80 11500 [745 | 815 | 7.60 12000 | 828 | 900 | 8.40 12500 | 9.54 | 1033 | 9.60 13000 | 10.70 | 11.58 | 10.65 13500 | 11.90 | 1290 _|_11.80 14000 [13.16 [1428 [13.25 KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN. INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55, Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.ac.id Load - Deflection Curve | Deflection a (mm) —pial1 —oial2 Dial 3 Gambar 2. Load Deflection Graph of sample II KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN ,, INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.ac.id Tabel 3. Test Results Measurement data | yy oat of Measurement data Moment Conclusion Monieat Sample | Perack | Moment | crack specs Pair | Momer (kg) (kgm) (kgm) (kg) (kgm) 1 | 9650 | 7933.4 7500 OK 19730 | 15983,1 2 | 10000) 82124 7500 ox 19500 | 15783,9 7. CONCLUSION From the test results it can be seen that the value of the second test specimen whole is greater than the specification.. Sample I reached Purack at P = 9650 kg.f > Pernck spec = 9106,17 kgf and moment formulas derived Merck = 7933,4.m > Merck spec = 7500 kg.m. Pultimate occurs at P = 19750 kgf and moment formulas derived My, — 15983,1 kg.m. Sample II reached Puck at P = 10,000 kg.f > Penck see = 9106,17 kg.f and moment formulas derived Moack = 8212,4 kg.m > Merck p00 ~ 7500 kg.m. Pusinate Occurs at P = 19500 kg.f and moment formulas derived Mu; = 15783,9 kgm. jbaya, November 29" 2012 Lee ry of Structure “ ae cease \itmeat of Civil Engineering ilty of- Civil and Planning (IP. : 19510309 1974122001 KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN , INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.ac.id Append. Grafie Log Machine Testing KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN | INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext, 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.ac.id 7 Picture A.1, Grafic Log Machine Sample I Z Picture A.2, Grafic Log Machine Sample II KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN , INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm-its.ac.id ppendix - B Photos Implementation KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN , INSTITUT NOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKATT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppmits.ac.id Picture B.1. Test Preparation Sample I Picture B.2. Production code sample 1 KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN INSTITUT TEKNOLOGI SEPULUH NOPEMBER: LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.ac.id Picture B.3. Sample I Picture B.4. Dial gauge potition KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN . INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Inpm@its.ac.id ; www.lppm.its.ac.id Picture B.S. Sample I reached crack Picture B.6. Ultimate at P = 19750 kgf KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.ac.id Picture B.8, Preparation of test sample Il KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext, 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.ac.id Picture B.9 Spun Pile of test sample IL Picture B.10, Sample II reaches crack KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN | INSTITUT TEKNOLOGI SEPULUH NOPEMBER. LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.ac.id Picture B.11. Ultimate at P = 19500 kgf Picture B.12. Pattern of cracked sample II KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : lppm@its.ac.id ; www.lppm.its.ac.id ee | gy Betell of Crack _ Picture B.12. Scheme cracked of sample 1 KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN - INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.ac.id P ate 9 sth i ROaF Detall of Crock Picture B.13, Scheme cracked of sample IL KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, $945473, $994251-5S Ext, 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.acid Appendix - C Calculation Of Moment KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.ac.id Porsckapee Calculation PC spunpile factory: Adhimix Precast Project 2 RFCC Project date of Test 28/1/12 Pile Spesification Product Spun Pile 400 Length (L) 698m Weight (q) : 199 kg/m! Merck sxe 7500 kgm (28 days) Testing Method Where: Ll, = 1396 m L 1,594 m Ly et a Calculating Re Rp = — 0.SP+0.5qL. M = RA(L;+0.5L;) - 0.125qL?- 0.25PLs = O.5PLy + 0.5qLL; + 0.25qLL, - 0.125qL7 re M,- 0.5qLL9 - 0.25qLL3 + 0.125qL” 0.3L TEM) = Merck spesitasi 80 Poe 9106168 kg MorceCalculation PC spunpile factory = Adhimix Precast Project RFCC Project Date of test 28/11/12 Product Spun Pile @400 Length (L) «om Weight (q) 1 kg/m! Posten 650 kg (Sample I~ result ofthe test) Testing M Where: LL = 1396 m lL = 1.594 m 5 = 1 m Rp = 05P+0.5qL = RA(L,+0.5L,) - 0.125qL?- 0.25PL; = O.SPLz + 0.5qLL + 0.25qLLy - 0.125qL? Moeasg — 7933.4 kgm > Menettcntinn = 7500 kgm va OK! KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN , INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55, Ext, 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.acid Mux Calculation PCspunpile factory: Adhimix Precast Project RFCC Project Date of test 28/11/12 Pile spesification Product Spun Pile 0400 Length (L) 68 om Weight (@) 199 kgimt Putte 9730 kg (Sample I - result of the test) ‘Testing Method P a B th Te Ty Lb G ———= Ser oe Where: h = 1.396 m Ty = 1.594 m Lh = ee Calculating: Ry Rp = 0.5P-+0.5qL M = RA(L;+0.5L) - 0.125qL?- 0.25PL; Masetest 0.SPLz + 0.5qLL> + 0.25qLL, - 0.125qL” = 1983.1 kgm KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN |, INSTITUT TEKNOLOGI SEPULUH NOPEMBER LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : Ippm@its.ac.id ; www.lppm.its.ac.id Merece Caleulation PC spunpile factory: Adhimix Precast Project : RFC Project Date of test 28/11/12 Pile spesification Product Spun Pile 0400 Length (L) 6% om ‘Weight (q) 199 kg/m! Peck tt oon kg (Sample II - result of the test) ‘Testing Method Where: lL = 1396 m lL iS 1.594 m Lo- 1 om Ra Ry = 0.SP+0.SqL M = RA(L;+0.5L2) - 0.125qL?- 0.25PL; = OSPLy + 0.SqLLy + 0.25qLL4 - 0.125qL? Mess 82124 kgm > Marge = 7500 kgm OK! KEMENTRIAN PENDIDIKAN DAN KEBUDAYAAN , INSTITUT TEKNOLOGI SEPULUH NOPEMBER, LEMBAGA PENELITIAN DAN PENGABDIAN KEPADA MASYARAKAT (LPPM) Kampus ITS Sukolilo, Surabaya, 60111 Telp. (031) 5944792, 5961214, 5945473, 5994251-55 Ext. 11113, 1121, 1273) ; Fax. (031) 5996670 Email : lopm@its.ac.id ; www.lppm.its.ac.id M,yCaleulation PC spunpile factory Adhimix Precast Project RFCC Project Date of test 28/11/12 Pile spesification Product Spun Pile 0400 Length (L) os om Weight (q) 199 kg/m! Puitest 19500 kg (Sample Il - result of the test) ‘Testing Method Where: Lo = 1.396 m Lb = 1.594 m = 1 oom Rap = 0.SP+0.5qL M = RA(L>+0.5L4) - 0.125qL?- 0.25PLs = 0.5PLz + 0.SqLL2 + 0.25qLL5- 0.125qL? zx 0 15783.9 kgm SUE Noperter JURUSAN TEKNIK SIPIL FAKULTAS TEKNIK SIPIL DAN PERENCANAAN Gedung Teknik Sip, L.1, Kampus ITS Sckolia, Surabaya 60411 [a * Hari /Tanggal © Tempat * Kegiatan DAFTAR HADIR : Rabu, 28 Nopember 2012 : Laboratorium Struktur- Workshop Jurusan Teknik Sipil TSP - ITS # Pengetesan Tiang Pancang 6400 L= 7 m (PT. Adhimix Precast Indonesia) JASA RALipRAst V KAN Komite Akreditasi Nesional INDO INDONESIA, PT ee [ Certificate No. = Page | C.12.07.206 Page 1 of 3 CALIBRATION CERTIFICATE | Glient (user) 2 Laboratorium Struktur | ‘Teknik Sipil - Institut Teknologi Sepuluh Nopember | Address Kampus ITS Sukolilo-Surabaya Instrument description Universal Testing Machine Brand/Type Torsee/ PBC-100tf Serial No. 21057 Date of instrument receipt 2 O4 July 2012 Calibration date 2 04 July 2012 Re-Calibration date 2 03 July 2013 Calibration location : Laboratorium Struktur - Teknik Sipil ITS Calibration method : ASTME4-10 ‘Standard practice for force verification of testing machines Environmental : Temp. :26°C Humidity : 56% CALIBRATION RESULT SEE PAGE 2 OF 3 and PAGE 3 OF 3 TRACEABILITY Unit measurement traceable to SI Unit through Deutscher Kalibrierdienst DKD-K-00101, Germany OPINION ‘The Universal Testing Machine meets the requirement of referenced calibration method, ‘The results in this calibration certificate relate only to the instrument to be calibrated PT. JASA KALIBRASI INDONESIA 1 | | ‘Abdul Gafur Operation Manager PURI INDAH, BLOK F No. 3 SUKO, SIDOARJO 61224 JAWA TIMUR, INDONESIA. Telp. +62-31-8953135 Fax. +6]-31-8953135 Email. info@jakindo.co.id www jakindo.co.id JASA anneal Y KAN Komite Akceditas Nasional KKINDO INDONESIA, PT “RCN Certificate No. Date Page ] €.12.07.206 july 2012 Page 2 of 3 J CALIBRATION RESULTS Range : 10.000 kg Calibrator Reading | Instrument Reading een) Limit | Uncertainty (ke) (ke) Error=A-B [Ep=[(A-B)/B]x100| (4) (ke) (ke) (4) 3.000 3.020 20, O7 10 6000 | 6.083 53, 09 210 9.000 9.020 20 02 210 NOTE : The instrurcent readings are average value, taken from three measurements ‘ZERO INDICATOR READING After 30 seconds removing the maximum force (10.000 kg), the indicator reading was 0.00 kg (tolerance is 10 kg) CALIBRATION RESULTS Range : 25.000kg Calibrator Reading | Instrument Reading Limit | Uncertainty (ke) (ke) (%) ke) 7.500 7575, 310 15.000 15.133 #10 pe 22.500 22.517 210 25.000 24.967 21,0 NOTE : The instrument readings are average value, taken from three measurements ZERO INDICATOR READING ‘After 30 seconds removing the maximum force (25.000 kg), the indicator reading was 0.00 kg (tolerance is 25 kg) PURI INDAH, BLOK F No. 3 SUKO, SIDOARJO 61224 JAWA TIMUR, INDONESIA Telp. +62-31-8953135 Fax. +61-31-8953135 Email. info@jakindo.co.id wwwJakindo.co.Id JASA KALIBRASI INDO INDONESIA, PT KAN Komite Akseditasi Nasional Lembaga Kalibras! 1K-124-IDN Certificate No. ___Dat 2 Page ] €.12.07.206 4 july Page 3 of 3 } CALIBRATION RESULTS Range : 50.000 kg Error (kg) Calbrator Reading, | Instrument Reading | =e} init | Uncertain Oe) ) iror=A-B | Ep=[@-B)/ Bly ) te) ©) i 15.000 15.150 150 10 310) 30.000 30033 | 33 om 10 45.000 44.767 "238 “05 | #10 '50.000 49.550 450 09 #10 NOTE : The instrument readings are average value, taken from three measurements ZERO INDICATOR READING ‘After 30 seconds removing the maximum force (50.000 kg), the indicator reading was 0.00 kg (tolerance is 50 kg) CALIBRATION RESULTS Range : 100.000 kg Error (kg) Calibrator Reading | Instrument Reading Limit | Uncertainty (a) ke) Error=A-B [Ep=[(AB)/B]x100| —(%) (re) (ks) (6) 30.000 30300 300 10 a0 60.000 ‘60600 600 10 #10 90.000 90367 367, o4 #0 NOTE : The instrument readings are average value, taken from three measurements ‘ZERO INDICATOR READING After 30 seconds removing the maximum force (100.000 kg), the indicator reading was 0.00 kg (tolerance is 100 kg) PURI INDAH, BLOK F No. 3 SUKO, SIDOARJO 61224 JAWA TIMUR, INDONESIA Telp. +62-31-8953135 Fax. +61-31-8953135 Email. info@jakindo.co.id www jakindo.co.id

Anda mungkin juga menyukai