CORBEL GEOMETRY

Width of Corbel
Total thickness of corbel
Depth to main reinforcement

b=
h=
d=

300
500
450

MATERIAL PROPERTIES
Yield strength of reinforcement
Compressive strength of concrete
Type of concrete
Unit weight of concrete
Corbel construction
Coefficient of friction

fy =
f'c =
Normal weight
=
Monolithic
= 1.4 =

415
35

DESIGN LOAD DATA


Factored vertical load
Distance of vertical load from face of column
Horizontal force acting on corbel
Strength reduction factor

Vu =
a=
Nuc =
=

VERTICAL LOAD CAPACITY CHECK


Nominal vertical load
Nominal vertical load capacity

FIND SHEAR FRICTION REINFORCEMENT


Minimum horizontal force acting on corbel
Horizontal force acting on corbel

1
1.4

370
100
75
0.75

Vn = Vu / =
Vn_cap = min(0.2 f'c b d, 5.5MPa b d) =
PASS (Vn is less than Vn_cap)

Nuc_min = 0.2 Vu =
Nuc_act = max(Nuc, Nuc_min) =

For balanced condition


Area for shear friction reinforcement
Nominal area required
MAIN TENSION REINFORCEMENT CHECK
Minimum area of tension reinforcement
Area of tension reinforcement required
Diameter of tension bars
Number of tension bars
Main tension reinforcement
Area of tension reinforcement provided

HORIZONTAL REINFORCEMENT CHECK


Minimum area of horizontal reinforcement
Area of horizontal reinforcement required
Diameter of tension bars
Number of tension bars
Horizontal reinforcement
Area of horizontal reinforcement provided
Maximum spacing of horizontal bars
Actual spacing of horizontal bars

j=
0.85
Avf = Vn / ( fy) =
Af = [a Vu + Nuc_act(h d)] / ( fy j d) =
An = Nuc_act / ( fy) =

Asc_min = 0.04 f'c b d / fy =


Asc = max[(2 Avf / 3) + An , Af + An] =
Asc_req = max(Asc , Asc_min) =
D=
19
N=
3
3 19 mm dia.
Asc_prov = N D^2 / 4 =
PASS

Ah_min = 0.5(Asc_req An) =


Ah = max(Avf/3 , Af/2) =
Ah_req = max(Ah_min , Ah) =
D=
9
N=
3
3 9 mm dia.
Ah_prov = 2 N D^2 / 4 =
PASS
Sh_max = 2 d / (3 N) =
Sh =
100

DESIGN SUMMARY
Single corbel 300 mm wide by 500 mm deep with 35 MPa concrete and 415 MPa steel
Provide main tension reinforcement as 3 19 mm dia.
Provide main horizontal reinforcement as 3 9 mm dia. link bars spaced at 100 mm O.C.

mm
mm
mm

MPa
MPa

KN
mm
KN

493.33 KN
0.2 f'c b d, 5.5MPa b d) =
than Vn_cap)

(Nuc, Nuc_min) =

742.50 KN

74 KN
75 KN

849 mm2
uc_act(h d)] / ( fy j d) =
241 mm2

f'c b d / fy =
vf / 3) + An , Af + An] =
(Asc , Asc_min) =
mm
pcs
D^2 / 4 =

342 mm2

455 mm2
807 mm2
807 mm2

851 mm2

sc_req An) =
3 , Af/2) =
Ah_min , Ah) =
mm
pcs

283 mm2
283 mm2
283 mm2

D^2 / 4 =

382 mm2
100 mm

mm

nd 415 MPa steel

ced at 100 mm O.C.

CORBEL GEOMETRY
Width of Corbel
Total thickness of corbel
Depth to main reinforcement

b=
h=
d=

500
187
137

MATERIAL PROPERTIES
Yield strength of reinforcement
Compressive strength of concrete
Type of concrete
Unit weight of concrete
Corbel construction
Coefficient of friction

fy =
f'c =
Normal weight
=
Monolithic
= 1.4 =

345
35

DESIGN LOAD DATA


Factored vertical load
Distance of vertical load from face of column
Horizontal force acting on corbel
Strength reduction factor

Vu =
a=
Nuc =
=

VERTICAL LOAD CAPACITY CHECK


Nominal vertical load
Nominal vertical load capacity

FIND SHEAR FRICTION REINFORCEMENT


Minimum horizontal force acting on corbel
Horizontal force acting on corbel

1
1.4

200
100
75
0.75

Vn = Vu / =
Vn_cap = min(0.2 f'c b d, 5.5MPa b d) =
PASS (Vn is less than Vn_cap)

Nuc_min = 0.2 Vu =
Nuc_act = max(Nuc, Nuc_min) =

For balanced condition


Area for shear friction reinforcement
Nominal area required
MAIN TENSION REINFORCEMENT CHECK
Minimum area of tension reinforcement
Area of tension reinforcement required
Diameter of tension bars
Number of tension bars
Main tension reinforcement
Area of tension reinforcement provided

HORIZONTAL REINFORCEMENT CHECK


Minimum area of horizontal reinforcement
Area of horizontal reinforcement required
Diameter of tension bars
Number of tension bars
Horizontal reinforcement
Area of horizontal reinforcement provided
Maximum spacing of horizontal bars
Actual spacing of horizontal bars

j=
0.85
Avf = Vn / ( fy) =
Af = [a Vu + Nuc_act(h d)] / ( fy j d) =
An = Nuc_act / ( fy) =

Asc_min = 0.04 f'c b d / fy =


Asc = max[(2 Avf / 3) + An , Af + An] =
Asc_req = max(Asc , Asc_min) =
D=
20
N=
4
4 20 mm dia.
Asc_prov = N D^2 / 4 =
PASS

Ah_min = 0.5(Asc_req An) =


Ah = max(Avf/3 , Af/2) =
Ah_req = max(Ah_min , Ah) =
D=
12
N=
2
2 12 mm dia.
Ah_prov = 2 N D^2 / 4 =
PASS
Sh_max = 2 d / (3 N) =
Sh =
46.00

DESIGN SUMMARY
Single corbel 500 mm wide by 187 mm deep with 35 MPa concrete and 345 MPa ste
Provide main tension reinforcement as 4 20 mm dia.
Provide main horizontal reinforcement as 2 12 mm dia. link bars spaced at 46 mm

mm
mm
mm

MPa
MPa

KN
mm
KN

266.67 KN
0.2 f'c b d, 5.5MPa b d) =
than Vn_cap)

(Nuc, Nuc_min) =

376.75 KN

74 KN
75 KN

552 mm2
uc_act(h d)] / ( fy j d) =
290 mm2

788 mm2

f'c b d / fy =
278 mm2
vf / 3) + An , Af + An] =
1078 mm2
(Asc , Asc_min) =
1078 mm2
mm
pcs
D^2 / 4 =

1257 mm2

sc_req An) =
3 , Af/2) =
Ah_min , Ah) =
mm
pcs

394 mm2
394 mm2
394 mm2

D^2 / 4 =

452 mm2
46.00 mm

mm

concrete and 345 MPa steel

ink bars spaced at 46 mm O.C.

CORBEL GEOMETRY
Width of Corbel
Total thickness of corbel
Depth to main reinforcement

b=
h=
d=

200
355
305

MATERIAL PROPERTIES
Yield strength of reinforcement
Compressive strength of concrete
Type of concrete
Unit weight of concrete
Corbel construction
Coefficient of friction

fy =
f'c =
Normal weight
=
Monolithic
= 1.4 =

345
35

DESIGN LOAD DATA


Factored vertical load
Distance of vertical load from face of column
Horizontal force acting on corbel
Strength reduction factor

Vu =
a=
Nuc =
=

VERTICAL LOAD CAPACITY CHECK


Nominal vertical load
Nominal vertical load capacity

FIND SHEAR FRICTION REINFORCEMENT


Minimum horizontal force acting on corbel
Horizontal force acting on corbel

1
1.4

250
100
75
0.75

Vn = Vu / =
Vn_cap = min(0.2 f'c b d, 5.5MPa b d) =
PASS (Vn is less than Vn_cap)

Nuc_min = 0.2 Vu =
Nuc_act = max(Nuc, Nuc_min) =

For balanced condition


Area for shear friction reinforcement
Nominal area required
MAIN TENSION REINFORCEMENT CHECK
Minimum area of tension reinforcement
Area of tension reinforcement required
Diameter of tension bars
Number of tension bars
Main tension reinforcement
Area of tension reinforcement provided

HORIZONTAL REINFORCEMENT CHECK


Minimum area of horizontal reinforcement
Area of horizontal reinforcement required
Diameter of tension bars
Number of tension bars
Horizontal reinforcement
Area of horizontal reinforcement provided
Maximum spacing of horizontal bars
Actual spacing of horizontal bars

j=
0.85
Avf = Vn / ( fy) =
Af = [a Vu + Nuc_act(h d)] / ( fy j d) =
An = Nuc_act / ( fy) =

Asc_min = 0.04 f'c b d / fy =


Asc = max[(2 Avf / 3) + An , Af + An] =
Asc_req = max(Asc , Asc_min) =
D=
16
N=
4
4 16 mm dia.
Asc_prov = N D^2 / 4 =
PASS

Ah_min = 0.5(Asc_req An) =


Ah = max(Avf/3 , Af/2) =
Ah_req = max(Ah_min , Ah) =
D=
12
N=
2
2 12 mm dia.
Ah_prov = 2 N D^2 / 4 =
PASS
Sh_max = 2 d / (3 N) =
Sh =
102.00

DESIGN SUMMARY
Single corbel 200 mm wide by 355 mm deep with 35 MPa concrete and 345 MPa ste
Provide main tension reinforcement as 4 16 mm dia.
Provide main horizontal reinforcement as 2 12 mm dia. link bars spaced at 102 m

mm
mm
mm

MPa
MPa

KN
mm
KN

333.33 KN
0.2 f'c b d, 5.5MPa b d) =
than Vn_cap)

(Nuc, Nuc_min) =

335.50 KN

74 KN
75 KN

690 mm2
uc_act(h d)] / ( fy j d) =
290 mm2

f'c b d / fy =
vf / 3) + An , Af + An] =
(Asc , Asc_min) =
mm
pcs
D^2 / 4 =

429 mm2

248 mm2
750 mm2
750 mm2

804 mm2

sc_req An) =
3 , Af/2) =
Ah_min , Ah) =
mm
pcs

230 mm2
230 mm2
230 mm2

D^2 / 4 =

452 mm2

102.00 mm
mm

concrete and 345 MPa steel

ink bars spaced at 102 mm O.C.