http://biz.lgservice.com
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
- 1-
Product Specifications
Model
Cooling Capacity
Heating Capacity
Power Input
Running Current
Starting Current
Max Current
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
EER
COP
Power Supply
Power Factor
Air Flow Rate
Moisture Removal
Indoor,Max
Outdoor,Max
Indoor,H/M/L/LL
Outdoor,Max
Refrigerant & Charge (R410A)
Additional Refrigerant charge g/m(oz/ft)
Type
Model
Motor Type
Compressor
Oil Type
Oil Charge
O.L.P. name
Type
Fan(Indoor)
Motor Type
Motor Output
Type
Fan(Outdoor)
Motor Type
Motor Output
Circuit Breaker*
Power Supply Cable
Noise Level
LG
Buyer
kW
Btu/h.
kW
Btu/h.
W
A
A
A
W/W
Btu/h.W
W/W
/ V / Hz
%
/min(CFM)
/min(CFM)
l/h.
dB(A)1
dB(A)1
g(oz)
cc
W
W
A
No.*
No.*
Piping Connections
Liquid Side
Gas Side
mm(in)
mm(in)
Drain Hose
O.D / I.D
mm(in)
Dimensions
Net Weight
Gross Weight
Operation Range
Indoor (W*H*D)
Outdoor (W*H*D)
Indoor
Outdoor
Indoor
Outdoor
Cooling(Outdoor)
Heating(Outdoor)
US-Q242MSW4
VM242CS
1,08~6,30~6,86
3 685~21 500~23 400
1 965/9,30/9,30/11,5/3,21
10,95
1/220/60
96
18,6(657)
50,0 (1 766)
1,9
47/42/37/31
Cooling55 Heating56
1 100(38,80) at 5m
30(1,05)
Rotary
GKT176MF
BLDC
FVC68D
470
Cross Flow Fan
BLDC
30
Propeller, Fan
BLDC
85
20
3 x 1,5
4 x 0,75
(Including Earth)
6,35(1/4)
15,88(5/8)
21,5 / 16,0
(0,85 / 0,63)
885 x 296 x 236
34,8 x 11,7 x 9,3
870 x 655 x 320
34,3 x 25,8 x 12,6
9,5(20,94)
41,7(91,93)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
kg(lbs)
kg(lbs)
C(F)
C(F)
m(ft)
m(ft)
11,0(24,25)
47(103,61)
18 ~ 48(64,4~118,4)
20(49,2)
10(32,8)
SM + UE
O
O
O
O
O
3/4/Auto
Manual
Wireless LCD
(Better-Remocon)
18C ~ 30C
1
O
O
24h, On/Off
O
O
O
3
O
-
Temperature Increment
Auto Operation (Micom Control)
Auto Changeover (Micom Control)
Self Diagnosis
Timer
Sleep Operation
Soft Dry Operation
Turob Dry Operation
Restart Delay (minute)
Deice Control(Defrost)
Hot Start
Jet Cool ,Jet Dry
Low Ambient Operation
Special Function
Cooling
Heating
Note:
O : Applied, - : No relation
* For circuit breaker rating, please conform to local standards wherever necessary.
- 2-
2. Piping Diagrams
Model : US-Q242MSW3
Indoor Unit
Outdoor Unit
Liquid Side
Capillary
Tube
Th2
Th1
Heat
Exchanger
(Evaporator)
Heat
Exchanger
(Condenser)
Th5
Th4
Gas Side
Compressor
LOC.
Description
PCB Connector
Th1
CN-TH1(Indoor)
Th2
CN-TH2(Indoor)
Th3
CN-TH2(OUTDOOR)
Th4
CN-TH1(OUTDOOR)
Th5
CN-TH1(OUTDOOR)
- 3-
3. Wiring Diagrams
Indoor Unit
CN-U/D
CN-DISP2
CN-DISP1
CN-TH2
CN-TH1
-4-
Outdoor Unit
CN_FAN(DC)
CN_TH1
CN_U_V_W
CN_LGM
CN_TH2
CN_4WAY
CN_COM
P(L)_BR
WCN_GND2
CN_COIL2
WCN_GND2
-5-
CN_COIL1
P(N)_BL
Exploded View
USNQ242MSW3
135316
268711A
152302
131410
135303
733010
149303
149304
354210
342800
135500A
267110
135080
354212
359011
346810
352150
146811
263230A
268711C
145200A
W51620A
135500C
W51620B
35211B
263230B
147582A
145200B
147582B
249951
W6640
147581
135511
435301
237202
437211
430411
349480
559010
549610
546810
261704
W6640
649950
435512
447910
268711C
263230A
550140
554160
W6631
35211A
148000
352113
554031
552203B
552203A
135511
435511
263230B
437212
Outdoor Unit
Model : USUQ242MSW3
P/NO : MFL67880912
November, 2013