5756
2013, DESIDOC
Nomenclature
Af
Mean sectional area of void space
Ar
Area of regenerator cross-section
At
Regenerator tube cross-sectional area
Cm
Specific heat of matrix material
dm Mesh wire diameter
dr
Internal diameter of regenerator tube
hm
Mean heat transfer coefficient
k
Thermal conductivity
l
Length
lm
Mesh distance
M
Mass of matrix
n
No. of wire mesh screens
NTOTAL Total of different mesh size considered
r
Compression ratio
T
Temperature
t
Blow time
u
Velocity of fluid in matrix
Density
Kinematic viscosity
Subscripts
m of matrix
f
of fluid
r
Regenerator
0
Void space
c
Compression
e
Expansion
1. INTRODUCTION
Currently a large number of infrared (IR) detectors for
night vision devices and missile guidance systems are in use.
The temperature needed for cooling these detectors are, for
571
2.1 Results
The prototype was tested for its performance using dummy
vacuum jacket around the cold tip with a vacuum of the order of
10-5 millibar. Heat load was externally applied using a resistive
heater element and cold tip temperature was monitored using
a PT-100 RTD. Experimental results are shown in Fig. 1(b).
The cold-tip temperature well below the required 80 K mark
achieved at no-load conditions is shown in Fig. 1(b) which was
obtained during a typical 100 h test.
3. INTEGRAL CRANK DRIVEN CRYOCOOLER
As the work on the development of 320 x 256 MW
IRFPA progressed at SSPL, requirement changed to smaller,
compact and high efficiency cryocoolers. Therefore, the focus
was shifted to the development of rotary integral cryocoolers.
Earlier the rotary coolers were using dry rubbing seals which
were a limiting factor in terms of reliability and lifetime
as compared to linear motor cryocoolers. Later, with the
advancement in manufacturing technology, rubbing seals
were replaced by dynamic clearance seals, making the rotary
coolers comparable to the linear motor systems in terms of
lifetime and reliability. The integrated detector/dewar cooler
assembly (IDCA) configuration was chosen owing to a number
of advantages offered by this over linear motor coolers. The
relevant system description and developmental work is
presented in the following sections.
temperatUre (k)
(a)
(b)
time (hrs)
Figure 1. (a) Linear motor driven dual piston split cryocooler prototype of capacity 0.5W@80K (b) Cold-tip temperature during long
performance run with Input power of 32 W.
572
wear. Further, the motor winding has been kept out of Helium
atmosphere with the use of thin cylinder, called the pressure
membrane, for keeping the cooler operation cleaner and free
from winding contamination. The metallic seals have been
used for final sealing of the cooler for reducing the leak rates
to minimum and more importantly for obviating the need for
welding. The IDCA cryocooler prototype developed having a
cooling capacity of 0.5W@80K with steady state power input
of less than 10 W is shown in Fig. 3.
573
VE . pmean ...sin
(3)
[ (1 2 ) + 1]
= tan 1
.sin
+ .cos
is
(4)
2 + 2 + 2.. + 2 S
+ + 2S
(5)
2X
+1
(6)
pmax (1 )
[1 + .cos( )]
(7)
pmax , is given by
1+
1
(8)
(1 )1/ 2 ..sin
(1 + ).(1 + )1/ 2 .[1 + (1 2 )1/ 2 ]
(9)
W = Qc Qe = ( 1).Qe
(10)
where the heat of compression or the heat rejected by the
system, Qc, is given as
1
Ve = VE (1 + cos )
(1)
2
If the phase lag between the piston and displacer is , then
volume variations of compression space is defined as
1
Vc = VE (1 + cos( ))
(2)
2
by:
574
Qc = .Qe
(11)
Then the ideal Coefficient of Performance COPideal is give
Qe
Tc
1
=
=
W 1 Tc Te
(12)
Likewise Eqn. (9), a term dimensionless cyclic work
input W* may be defined using Eqn. (10) and can be written
as follows.
COPideal =
(13)
W * = ( 1).Qe*
Q
COPactual =
(14)
P
where Q is the actual cooling capacity of real system and P
is the corresponding actual power input. The term Carnot
efficiency gives the numerical value of the deviation from the
most ideal behavior, and is defined as8
COPactual
(15)
Carnot =
COPideal
Considering the most ideal behavior of the cooler and
using Eqn. (12), for cooler working in the temperature range of
Tc=300K and Te=80K the COPideal comes out to be 0.36. Now,
consider the actual typical miniature cooler, as is our case, with
cooling capacity of 0.5W and power input of 15W, COPactual
value is around 0.033, and the Carnot efficiency as calculated
from Eqn. (15) is barely 0.092, and a large amount of the power
is consumed in overcoming the losses. Hence, a system level
loss assessment is necessary for producing efficient coolers.
Broadly, the losses can be divided into the following two
categories18.
a. Losses that consume the fraction of input power available
for the refrigeration like joule heating in coil windings
and irreversible compression etc., and are mostly related
to the compressor part.
b. Losses that consume a part of refrigeration directly, and
are related to the expander side.
In the present study the second category of losses have
been considered, since these have direct impact on the coolers
performance and can be controlled with less effort as compared
to the other losses.
(a)
Figure 5.
(b)
Effect of design parameters on dimensionless heat extraction and/or work done for different dead volume ratios X: (a)
Phase angle (b) Swept volume ratio .
575
Regenerator Losses
where Qnet is actual net refrigeration available for cooling
the application load, i.e. the detector array, Qe is maximum
refrigeration available in ideal Stirling cycle as given in Eqn.
(3), the bracketed values are the sum of all the losses in which
Qief is the loss due to thermal ineffectiveness of regenerator,
Qp f is the loss due to frictional pressure drop Qrt is conduction
loss associated with regenerator tube, Qcmg is longitudinal
conduction loss of regenerator matrix whereas Qshtl and Qcf
are the shuttle heat transfer loss and dewar (conduction and
radiation) losses respectively. The following sub-sections
cover the analysis of these losses, with a special emphasis
given to the regenerator design optimization as an outcome of
this analysis.
(17)
Crs
[(exp( Ntu )
Ntu (1 + Crs ) 2
Ntu / Crs
[1 + 2Crs + (1 + Crs )(
Ntu
z ) + ...
Crs
Ntu
z )}]exp( z ).I 0 .(2. Ntu.z ).dz
Crs
Ntu (1 + Crs ) 2
(1 + Crs ) Crs[1 exp{(1 + Crs )})]
Crs
Ntu
.... For ( >
)
Crs
Crs
=
Ntu (1 + Crs ) 2
.... For (
Ntu (1 + Crs ) 2
Crs
Ntu
)
Crs
(18)
where
Ntu =
hm . A
M .Cm
M .Cm
Ntu
, =
, Crs =
, Cr =
m .C p
lr . Af .0 .C p
m .C p .t
Cr
where Cr and Crs are the heat capacity ratios of matrix material
to the fluid flowing through the matrix and matrix material
to fluid in void volume respectively. Further, the function
(2. Ntu.z ) is modified Bessel function of the first kind of the
order zero. The heat transfer coefficient is calculated as
k f .N ud
h=
(19)
dm
where N ud = 0.42 R e d 0.56 where N ud is Nusselt number for
wire screen and Reynolds number is given as
d u
Red = m
(20)
3.3.1.2 Pressure Drop Loss
The pressure drop loss caused by the frictional flow
across the regenerator matrix which reduces the magnitude
of the pressure available for expansion thereby reducing the
area of expansion space p-v diagram and the gross refrigeration
produced. The pressure drop is expressed as15
(21)
p f = f ..u 2 .n / 2
The flow friction factor f is defined as
33.6
+ 0.337
Rel
(22)
where Rel is Reynolds number can be evaluated as
l .u
(23)
Rel = m
The pressure drop loss can be calculated from the
following equation12:
f =
Qe .p f
Qp f =
(24)
Pa
where Pa is pressure amplitude of the cycle, which is given in
terms of compression ratio as
r 1
Pa = Pmean
+1
r
(25)
(1 + km / k f ) (1 ).(1 km / k f )
(1 + km / k f ) + (1 ).(1 km / k f )
(28)
(30)
3.3.3 Results
The computation of losses and regenerator design
optimization has been done considering the IDCA cooler data
given in appendix. For this purpose a code has been written
in MATLAB. The flow chart of the methodology followed
is shown in Fig. 6. Various wire-mesh sizes ranging from
100 to 500 mesh number have been selected for the analysis.
Mesh-sizes below 100 are not considered due to very low
losses w
Regenerator efficiency
(a)
(b)
Figure 7. (a) Regenerator losses for a 400 mesh size (b) Regenerator efficiency for different mesh sizes.
Table 1. Heat balance sheet for IDCA cryocooler
Regenerator ineffectiveness loss, Qief
2.26 W
1.15 W
0.04 W
0.33 W
0.32 W
4.10 W
5.07 W
0.97 W
0.20 W
0.77 W
Cold tip
temp (K)
PD-01
70.3
Max.
Regulated
power (W) power (W)
15 - 16
--
Cool down
time (Min)
Ambient
temp (C)
Heat load
(mW)
Status
Continuous
running
(hrs)
Failure
mode
Remarks
6-7
25
350
operating
50
None
To test the
endurance of
regenerators
Hard
chromium
coating on
piston
Ti- Nitride
coating on
piston
PD-02
77
15 - 16
--
6-7
20
350
failed
59
Bearing
failure
PS-I
80
15
15
285
failed
20
Bearing
failure
578
4.
CONCLUSION
In this paper a brief review of the activities related to the
development of miniature Stirling cryocoolers especially suited
to IR sensor cooling applications has been presented. The
technology for linear split and rotary integral coolers have been
explained in due details. Thermodynamic analysis including
the loss analysis has been presented from design point of view
with a special emphasis on regenerator design optimization.
The theoretical as well as the relevant experimental results
have been presented and discussed.
Prototypes of both split and integral types have been
tested in laboratory and also integrated with the thermal sight
successfully. Optimization efforts to enhance the reliability
and life time are still in progress. We expect to achieve these
goals by carrying out further design modifications and will be
in a position to predict MTTF of the coolers once produced in
sufficient numbers. The cryocooler will also be subjected to
environmental testing to make it usable in field application in
future.
ACKNOWLEDGEMENT
Authors are grateful to Director, Solid State
Physics Laboratory (SSPL) for his constant support
and encouragement during the course of this work. We
are grateful to Mr Saket Mital, Mr K. Upadhayay and
Mr Ramesh Chandra for their help in conducting experiments
and documentation work. Thanks are also due to the SSPL
workshop staff for fabrication of components.
REFERENCES
1. Richard, D. Hudson. Jr. Infrared system engineering. John
Wiley & Sons, New York, 1969. pp.642
2. Breckenridge Jr, R.W. Cryogenic coolers for IR systems.
Optical Engineering, 1975, 14(1), 140-157.
3. Walker, G.; Fauvel, R. & Reader, G. Miniature
refrigerators for cryogenic sensors and cold electronics.
Cryogenics, 1989, 29(8), 841-845.
4. Walker, G. Miniature refrigerators for cryogenic sensors
and cold electronics. Clarendon Press, Oxford New York,
1989. 204 p.
5. Stolfi, F. & De Jonge, A. K. Stirling cryogenerators with
linear drive. Philips Tech. Rev. , 1985, 42(1) , 1-10.
6. De Jonge, A.K. & Sereny, A. Analysis and optimisation
of linear motor for compressor of a cryogenic refrigerator.
In Advances in cryogenic engineering, 1982, 27, pp. 631640.
7. Koh, D.Y.; Hong, Y. J.; Park, S.J.; Kim, H.B. & Lee, K.S.
A study on the linear compressor characteristics of the
Stirling cryocooler. Cryogenics, 2002, 42(6), 427-432.
8. Walker, G. Cryocoolers Part 1: Fundamentals. Plenum
Press, New York and London, 1983. 364 p.
9. Tailor, P.R. & Narayankhedkar, K.G. Thermodynamic
analysis of the Stirling cycle. Cryogenics, 1988, 28(1),
36-45.
10. Orlowska, A.H. & Davey, G.. Measurement of losses in a
Stirling cycle cooler. Cryogenics, 1987, 27(11), 645-651.
11. Reed, J.S.; Davey, G.; Dadd, M.W. & Bailey, P.B.
Compression losses in cryocoolers. Cryocoolers, 2005,
579
13, 209-214.
12. Yang, X. & Chung, J. N. Size effects on miniature Stirling
cycle cryocoolers. Cryogenics, 2005, 45(8), 537-545.
13. Chhatwal, H.L.; Goswami, T.R., & Dewakar, R.K.
Miniature linear motor driven integral type Stirling cooler
for laboratory use. Indian J. Pure Appl. phys., 1992,
30(12), 771-772.
14. Chhatwal, H.L.; Goswami, T.R. & Dewakar, R.K.
Prototype miniature split Stirling cryo-cooler. Indian J.
Pure Appl. phys., 1993, 31(11), 794-797.
15. Miyabe, H.; Hamaguchi, K. & Takahashi, K. An approach
to the design of Stirling engine regenerator matrix using
packs of wire gauzes. In Proceeding IEEE, IECEC, 1982,
17, pp. 1839-1844.
16. Hanselman, Duane C.Brushless permanent-magnet motor
design. McGraw-Hill, New York, 1994, 392p.
17. Ruehlich, I.; Korf, H. & Schellenberger, G. Advanced
control electronics for Stirling cryocoolers. In Proceedings
of SPIE, 2002, 4820, pp. 15-25.
18. Thirumaleshwar, M. & Subramanyam, S. V. Heat
balance analysis of single stage Gifford-McMahon cycle
cryorefrigerator.Cryogenics, 1986, 26(3), 189-195.
19. Pande, G.V. & Narayanamurthy, H. Design studies for
stirling cycle cooler regenerator. J. Spacecr. Techno.,
1995, 5(1), 57-63.
20. Chang, H. M.; Park, D. J. & Jeong, S. Effect of gap flow on
shuttle heat transfer. Cryogenics, 2000, 40(3), 159-166.
21. Zimmerman, F.J. & Longsworth, R.C. Shuttle heat
transfer. In Advances in cryogenic engineering. 1970, 16,
pp. 342-351.
22. Andeen, B.R. Heat capacity and geometry impacts on
regenerator performance. In Advances in Cryogenic
Engineering. 1982, 27, pp. 611-619
23. De Waele, A.T.A.M. Finite heat-capacity effects in
regenerators. Cryogenics, 2012, 52(1), 1-7.
Contributors
Mr Manmohan Singh obtained his M.E
(Thermal Engineering) from Delhi college
of Engg., Delhi University. Presently, he
is working as Head, Cryogenics Group,
SSPL Delhi. His research interest includes
manufacturing technology and Stirling
cryocoolers.
Mr Sunil Suchdev received his AMIE degree
in Mech. Engg. He is working as Scientist
in Cryocooler Group and his current interests
include the development of cryocooler
systems for defence applications.
APPENDIX
SS Wire mesh parameters
Cryocooler parameters
Nominal speed
4000 rpm
Stroke length
2 mm
2.87
3.48
Phase angle
90 o
Ambient temperature
300 K
Cold-tip temperature
80 K
190 K
Charge pressure
Piston diameter
Specific heat
0.4 kJ/kg.K
Thermal conductivity
12.6 W/m.K
400
Regenerator parameters
0.5 mm
25 bar
6.5 mm
14 mm
6.33 kg/m3
0.3 W/m.K
Regenerator length
38 mm
35 m
5.19 kJ/kg.K
40
0.11 W/m.K
Capacity ratio Cr
33
580
7900 kg/m3
Density
1.46E-05 N.s/m2