Anda di halaman 1dari 4

Vital Relays and Timers

Ansaldo STS USA


(Formerly known as Union Switch & Signal)

RSE-4J1
Rev. 3-09

PV-250 Two-Element AC Vane Relay


The PV-250 relay is factory-calibrated to operate
across a wide environmental range. This relay is
used in numerous applications such as Power
Frequency Track Circuits and ground detector
systems. All moving parts are enclosed in a
sturdy, transparent, dust and moisture resistant
cover. To ensure the relay is inserted in its proper
mounting base, all relays have indexing pins.
Relays lock securely in the plug-in position.
General Description
PV-250 Track Circuit Relays: N322555-001, -002, 003, -004, -010, -801, -803, -804, -809, -909
These models of the PV-250V AC-vane relay used for
track circuit applications. Selected relays use a
double-wound coil that may be used in series or
parallel for the control element, and a local element
that presents the specified impedance. Other models
use a single-wound coil and locals element that
presents the specified impedance. Refer to the
ordering tabulations for complete specifications.

The relays are factory equipped with indexing pins to


prevent insertion of an incorrect relay into a mounting
base. Each relay is accompanied by an indexing
plate which is applied to the mounting base at the time
of initial installation.

Contacts of the PV-250 relay are standard low voltage


silver-to-silver impregnated carbon front and silver-tosilver back.

The relays are factory equipped with indexing pins to


prevent insertion of an incorrect relay into a mounting
base. Each relay is accompanied by an indexing
plate which is applied to the mounting base at the time
of initial installation.

Specifications and Applications

Refer to the ordering tabulation for operating


specifications and additional application notes.
Note on tabulations: Where two sets of data are
given for a relay, the top set covers control
windings in series and the bottom set control
windings in parallel. For relays having only one set
of data, the data are for control windings in series
only.

PV-250 Ground Detector Relays: N322555-005, -805


These models of the PV-250 is used for ground
detector applications. They are intended for use in a
special circuit in which the control winding is
connected between CX and ground with a series
resistor, and a capacitor is connected between BX
and ground. The local winding is energized through a
1.8 microfarad capacitor in series with a transformer
secondary, providing approximately 25 volts. Refer to
the ordering tabulations for complete specifications.
These relays use single wound coils for the control
and local elements that present the specified
impedance. Contacts are standard low voltage silverto-silver impregnated carbon front and silver-to-silver
back.

To order, call 1-800-652-7276


e-mail: orders@ansaldo-sts.us

Ordering Information

Standard relay and plug-in base order numbers


listed in tabulation and RSE-4R1.
When writing your order, specify the required
contacts and coil resistance.
Relay bases are ordered separately. Indicate the
type of relay to be used with that base.
For detailed specifications and service manual
parts lists, refer to the NOTES section of the
ordering tabulation. For detailed specifications and
service manual parts lists, refer to the NOTES
section of the ordering tabulation.

www.ansaldo-sts.com
RSE-4J1, p. 1

Ansaldo STS USA

PV-250 Two-Element AC Vane Relay

(Formerly known as Union Switch & Signal)

RSE-4J1
Rev. 3-09
Ordering Information (contd)

Refer to RSE-4S1 for shop maintenance tools and


supplies.

Order No.
N322555-001

N322555-002
N322555-004
N322555-005
N322555-010
N322555-801

N322555-804
N322555-805
N342555-003
N342555-803
N342555-809
N322555-909
N438689-003

Request ASTS USA Service Manual SM-4574 for


general adjustment procedures.

PV-250 Relays and Base


Front
P.U. +5% P.U. +5%
F.S.
F.S.
Test
Contacts Min. D.A.
Amp (a)
Volt (a) Amps (b) Volts (b)
X
6F, 4B
80% P.U.
0.283
0.418
0.487
0.720
80% P.U.
0.566
0.209
0.974
0.360
80% P.U.
0.278
0.360
0.478
0.620
80% P.U.
0.566
0.180
0.956
0.310
X
6F, 4B
80% P.U.
0.422
0.309
0.750
0.525
80% P.U.
0.844
0.155
1.500
0.269
X
6F, 4B
91% P.U.
0.158
97.00
0.181
111.000
X
6F, 4B
90% P.U.
0.115
3.670
0.160
5.100
X
6F, 4B
80% P.U.
0.510
0.300
0.770
0.430
-6F, 4B
80% P.U.
0.283
0.418
0.487
0.720
80% P.U.
0.566
0.209
0.974
0.360
80% P.U.
0.278
0.360
0.478
0.620
80% P.U.
0.566
0.180
0.956
0.310
-6F, 4B
91% P.U.
0.158
97.00
0.181
111.00
91% P.U.
0.153
94.00
0.179
108.00
-6F, 4B
90% P.U.
0.115
3.670
0.160
5.100
X
2F, 2B
90% P.U.
0.280
0.700
0.327
0.820
-2F, 2B
90% P.U.
0.280
0.700
0.327
0.820
-2F, 2B
90% P.U.
0.044
2.740
0.0495
3.050
-2F, 2B
(14)
0.165
115.0
(14)
(14)
Plug-In base for PV-250 (ref. RSE 4R1)
Note (a): Operating values at ideal phase relationships - pick-up
+5%
Note (b): Operating values at ideal phase relationships - full stroke.
Note (1): Contacts: Control coil in series.
Note (2): Contacts: Control coil in multiples.
Note (3): (Not used)
Note (4): Ground detector relay.
Note (5): (Not used)
Note (6): Contacts: 2,3: F 7,8: B
Note (7): Contacts - 1,2,3,6,7,8: F; 4,5,9,10: B
Note (8): Contacts - 7, 8: F; 9,10: B
Note (9): Track circuit relay.
Note (10): Track relay.
Note (11): Slow drop-away relay.
Note (12): Track relay.
Note (13): Track relay.
Note (14): Request ASTS USA Service Manual SM-4574F for these values.

Order No.
N322555-001
N322555-002
N322555-004
N322555-005
N322555-010
N322555-801

RSE-4J1, p. 2

PV-250 Service Manual Cross-References


Order No.
SM. No.
SM. No.
-4754A
N322555-804 -4574D
-4574B
N322555-805 -4574E
-4574D
N342555-003 -4574C
-4574E
N342555-803 -4574C
-4574G
N342555-809 -4574F
N342555-909 -4574F
-4754A

Local
Volts
115
115
110
110
115
115
115
115
115
115
115
110
110
115
110
115
115
115
115
115

Local
Hz
60.0
60.0
50.0
50.0
25.0
25.0
60.0
60.0
100.0
60.0
60.0
50.0
50.0
60.0
50.0
60.0
60.0
60.0
60.0
60.0

Notes
(1)(7)(9)
(2)
(1)
(2)
(7)(10)
(7)
(7)
(1)(4)(7)
(2)(7)(13)
(1)(7)(9)
(2)
(1)
(2)
(7)
(7)
(1)(8)
(1)(6)(11)
(6)(11)
(1)(8)(12)
--

PV-250 Two-Element AC Vane Relay

Ansaldo STS USA


(Formerly known as Union Switch & Signal)

RSE-4J1
Rev. 3-09
General Features of ASTS USA PN-Series Electro-Mechanical Vital Relays
ASTS USA vital and non-vital plug-in relays serve a
multitude of functions in both railroad and transit
control circuit applications. These time-proven relays
are space-saving, easily installed or removed and can
be handled in the field without disturbing coil or contact
wiring.
In addition to production of PN-series electromechanical relays at the same high standards, ASTS
USA also provides high-quality remanufacturing
services for these relays so that they can be returned to
service in like-new condition. Refer to the
Remanufacturing Services section of this catalog or
call 1-800-652-7276 for additional information.

Advantages

Other types of contact material for special application are


described with the particular relay. Standard contacts are
factory-adjusted to standard minimum opening and conform
to AREMA (AAR) requirements.
All vital plug-in relays incorporate a transparent molded
cover over the relay contacts and armature structure. The
cover is sealed to the frame with a gasket that assures a
tight, dust-proof and moisture-proof seal.

Contact Designations
Front and back contacts of plug-in relays are designated F
and B, respectively. The dependent contacts are denoted
FB, while the independent contacts are denoted F or B
alone.

Wide selection available for every application

Testing

Meets or exceeds applicable AREMA (AAR)


requirements

Many ASTS USA vital relays are provided a front testing


capability. The front testing facility is in series with the coil
control circuit to permit deenergization of the relay while it is
in its service mounting, without disturbing the relay or wiring.
Testing may also be accomplished through the rear of the
relay mounting base without opening a contact or coil circuit.
Refer to RSE-4S1 for special tools utilized in maintaining
ASTS USA plug-in relays.

Plug-in design permits quick installation or removal


Indexed to assure proper mounting
Sturdy plug-in base for every relay model
Operates over wide temperature range

High Quality Design and Assembly


All components of ASTS USA plug-in relays are constructed
according to rigid quality control standards and are
thoroughly tested before shipment. Coils are encapsulated
for protection against mechanical damage and moisture.
Magnetic circuits are constructed of non-aging materials.
The air gap is not disturbed when the coil is removed or the
contact springs adjusted. Those relays with an adjustable
magnetic shunt may be adjusted for degree of magnetic
hold-down force without changing the contact adjustment or
the hold-down pole-piece position.
Contact fingers and springs utilize a simple, reliable design
and are heat treated to assure uniformity of material and
contact stability. The heavy contact fingers extend through
the base to serve as plug connectors. Heel contacts are
actuated by operating arms pivoted to the armature. Contact
surfaces have sufficient wiping action to be self-cleaning.
Standard contact materials include fine silver heels and
backs, and silver-impregnated carbon (S.I.C.) fronts with a
typical capacity of 4A @ 30 Vdc or 175 Vac. Heavy Duty
(H.D.) contact materials also include fine silver heels and
backs and silver-impregnated carbon (S.I.C.) fronts with a
typical capacity of 15A @30 Vdc or 30 Vac.

Latch
A spring-operated latch holds each plug-in relay securely to
its mounting base. The latch is released by pressing a
button on the front of the relay.

Indexing
All plug-in relays are equipped with indexing pins to prevent
insertion of an incorrect relay into the mounting base. Each
relay is accompanied by an indexing plate that is applied to
the base at the initial installation.

System Voltage
This voltage, which is listed in the relay ordering tabulation
specifications, is prescribed for relays in locally energized
circuits. Higher voltage may be used, if required, up to 10
watts power dissipation.

RSE-4J1, p. 3