What is a GasCube?
16V34SG option
GasCube highlights
Low own consumption High electrical efficiency
low energy radiators with frequency control
efficient ventilation concept
no air conditioning
Minimized footprint
radiators on the roof minimum space, maximum
performance
control panels inside the cube no control room
Cost efficiency & project execution
elimination of repetitive design
minimization of material excess
streamlined no change order - project execution
containerized transportation
high level of pre fabrication
Integrated gas skid
exhaust gas module
3
-5+40 C
(+45 C special arrangements)
Zone 4, Occ. Cat. 3, UBC1997
110mph, Exp.C UBC1997
70 dB(A) 100m
Engine
Charge air filter type
Exhaust gas silencer
Overhead Crane
Wrtsil 20V34SG
Dry
35 dB(A) equipped with explosion relief
2500 kg
650 l/min
3,2 m3
Single
3,0 m3
Frequency
Control
Plant own consumption
50 or 60 Hz
power house / remote
about 1 % at full load
Cooling radiators
Single circuit
Ventilation
Max ambient inside power house
Intake air Louvre filtration
General 3D View
GasCube Building
Access Door
Lube Oil Area
MV-House
5
Plan 0.000
19.4 m
3
Outside
Dimensions
5.8 m
Building Area
113 m2
5
1
2
3
4
5
6
8
6
7
8
9
LV Switchgear
Control Panel
Frequency Converters
Neutral Point Cubicle
Plan 5.700
4
3
5
2
Roof Plan
1
1
1 Cooling Radiators
2 Expansion Vessel
3 Ventilation Roof Fan Unit
4 Stack
3D Section View
17.44 m
12,7 m
Radiator platform
7.9 m
Eave height
0.00
Floor
Height Levels
9
5
4
10
2
3
1
4
1
4
11
5
6
11
4
13
12
10
2
5
14
1
9
12
6
3
7
9
4
1
8
8
13
14
2
3
Fire Extinguishers
Dry
Powder
CO2
Dry
Powder
Extinguishers
Emergency Exit Doors
15
CO2
CO2
Interface principle
Optional MV-house
including:
16
LV
GAS
LUBE OIL
GasCube
MV
MV-switchgear
LV-switchgear
DC-system
Auxiliary transformer
MV
LV LV
MV
Radiator panel
Electrical panels
behind engine
17
Starting air
compressor panel
Electrical panels
Frequency converter
for ventilation
Frequency converter
for radiators
Gas alarm panel
Fire alarm panel
Oil mist separator
panel
Lighting panel
LV-switchboard
18
Control panel
Panel cooler
Control Panel
MW and PF meters
TO O
FAST
cos
MW
8
0.9
SYNC
TOO
SLO W
Hz
0.5
0.9
V
0.5
0 0000 000
MWh
SYNC CHECK
POWER FACTOR
ACTIVE POWER
Hz
Dei f
De if
Dei f
De fi
DOUBLE VOLTAGE
DOUBLE FREQUENCY
SELECTION
OF VOLTAGE
MEASURING
OPERATOR
PANEL
Manual synchronising
equipment
PMU
Powe r
=I1/ 5A
n U
=100. 1
. 60V
n
n =
=f50/ 60
H5V
z dc/ac
2
aux U80. . 6
Error
Seri al Com
Al arm
TRIP
VPG 2 10
Ge nerator protection
rela t
Vaasa Electronics
VVM
aasa AC
El cet o
r6nicBsA3
e ngin e
star t
stop
S7
S8
auto
m anual
Emergency stop
EMERGENCY
STOP
OPERATOR
CONTROLLER
PRELUBE
PUMP
EXHAUST
GAS FAN
voltag e
S9
S10
eng ine
shu tdo wn
b rea ker
trip
r ese t
re set
S11
S12
VENTILATION
FAN
decre ase
ex citation
increa se decre ase
S4
S5
0
GENERATOR
PROTECTION
2
MAINTENANCE
WATER PUMP
HT PREHEATER
=I1/ 5A
n =
. 60V
U100. 1
n
n U
=f50/ 60
H5V
z dc/ac
2
aux =80. . 6
Al arm
TRIP
VPG 2 10
Ge nerator protection
rela t
Vaasa Electronics
Mad e in Fin lan d
OPTION
OPTIO N
DIFFERENTIAL
PROTECTION
2
Powe r
=1/
I 5A
n U
=100. 1
. 60V
n
=50/
H5V
z dc/ac
f 60
n =
2
aux U80. . 6
Error
Seri al Com
Al arm
TRIP
VPG 2 10
Ge nerator protection
rela t
Vaasa Electronics
VM AC
Vaasa
El cet o
r6nicBsA3
Mad e n
i Fin lan d
19
VVM
aasa AC
El cet o
r6nicBsA3
TURNINGEAR
EMRG. STOP
Inside of panel:
PLC, Siemens S7-300
AVR, ABB Unitrol 1000
Voltage control
Synchronisation
Battery, 24VDC, 90Ah
select/sta rt
S6
S13
Powe r
GENERATOR
ANTIC. HEATER
increa se
Error
Seri al Com
Control of auxiliaries
Panel cooler
S3
fue l
ope n
p.f.
do
r op
S2
bre aker
closed
kW
si och
do
r op
S1
Generator protection
relay
Generator differential
relay
Width:
Depth:
Height:
Enclosure:
1200 + 260
400
2000
IP54
MV-House layout
LV-Switchgear
20
MV-switchgear
21
23
Plan View
3D View
25
Gravel
Asphalt
16 m
Grass
Site Area
752 m2
26
47 m
27.6 m
Site Area
1297 m2
47 m
27
28
29
30
31