Anda di halaman 1dari 21

Optix RTN 900 Radio Transmission System v1.

Optix RTN 900 Radio Transmission System


Microwave FATP Test Record
Microwave Scope of Work:
New Link

Swap Link

Customer / Project Name


Near End Site ID Name
Far End Site ID Name
Transmission Configuration
Microwave Scope of Work

:
:
:
:
:

INDOSAT JAGUAR PROJECT


14CLP022 - BINANGUN
14CLP004 - ADIPALA
RTN900/7G/1+0/1.2/161M

________________________________________

Optix RTN 900 Radio Transmission System v1.3

On this date _____________________, we the undersigned hereby certify that the


Radio Transmission System equipment at the above location is installed, tested and
accepted according to the attached Technical Test Protocol.

On behalf of PT. HUAWEI TECH INVESTMENT:

Signed:
Name:

Position:

On behalf of PT. INDOSAT:

Signed:
Name:

Position:

C O N T E N T:
1. Configuration Check
2. Receive Power Level Result
3. Interference Check
4. Cross Connection Service Configuration
5. Ethernet Interface
6. Ethernet Service Configuration
7. Browse Alarm Check
8. NE Visibility on NMS System
9. MW Link Performance Statistic
10. Inventory Software License

Optix RTN 900 Radio Transmission System v1.3

11. MW Capture

Optix RTN 900 Radio Transmission System v1.3

REVISION HISTORY
Date

Revision

Description

Authors

2014/ Dec/10

V1.0

Initial draft

Toni Riyanto

2015/ Jan/28

V1.1

Put: far-end site table in the below of


near-end site table

Toni Riyanto

2015/Mar/3

V1.2

Modify for all transmission vendor


- Additional license capture

Indosat, Huawei,
Alcatel, NEC
(Microwave team)

2015/Mar/21

V1.3

Put: Ping and ethernet test capture

Indosat, Huawei,
Alcatel, NEC
(Microwave team)

1)

Configuration Check

Near-End Site Set-Up


Frequency Plan (MHz)
Transmitted frequency (MHz)
Received frequency (MHz)
ODU Sub Band
Modulation
E1 Capacity
Ethernet Capacity (Mbps)
(*) if Applicable

Channel 1
7135.0
7198.0
7359.0
C

Channel 2 (*)

Channel 3 (*)

28M 128QAM
0
161

Channel 4 (*)

Optix RTN 900 Radio Transmission System v1.3


Far-End Site Set-Up
Frequency Plan (MHz)
Transmitted frequency (MHz)
Received frequency (MHz)
ODU Sub Band

Channel 1
7296.0
7359.0
7198.0
C

Channel 2 (*)

Modulation
E1 Capacity
Ethernet Capacity (Mbps)
(*) if Applicable

2)

Channel 3 (*)

Channel 4 (*)

28M 128QAM
0
161

Receive Power Level Result


Item

ODU 1

Rx level in link budget (dBm)

21.0

Rx Level (dBm)

-38.4

Tx Power (dBm)

21.0

ODU 1

Rx level in link budget (dBm)

Far-End Site
ODU 2
ODU 3
(*)
(*)

ODU 4
(*)

Remark

-38.92

TX Power in link budget (dBm)


Rx Level (dBm)

Remark
ODU 4
(*)

-38.92

TX Power in link budget (dBm)

Item

Near-End Site
ODU 2
ODU 3
(*)
(*)

21.0
-39.1

Tx Power (dBm)

21.0

(*) if Applicable

3)

Interference Check (refer to NDB)

Site Item
RX power level (dBm)

Site Item
RX power level (dBm)

4)

Near-End Site
Freq 1

Freq 2

Freq 3

Remark
Freq 4

-90.0

*Huawei-Indosat Interference tolerable value


Far-End Site

Freq 1

Freq 2

Freq 3

Remark
Freq 4

-90.0

*Huawei-Indosat Interference tolerable value

Cross connection Service Configuration (refer to NDB)


Item

Near-End Site

Remark

Item

Far-End Site

Remark

Near-End Site

Remark

E1 Capacity

E1 Capacity

5)

Ethernet Interface
Port

Optix RTN 900 Radio Transmission System v1.3


Enable
Port 1
Port 2
Port 3
Port 4
Port 5
Port 6

Port
Port 1
Port 2
Port 3
Port 4
Port 5
Port 6

6)

Disable

Far-End Site
Enable
Disable

17-EG6-1
17-EG6-1
17-EG6-1
17-EG6-1
17-EG6-1
17-EG6-1

Remark
1-EG4P-3
1-EG4P-4
2-EG4P-3
2-EG4P-4
17-EG2D-1
17-EG2D-2

Ethernet Service Configuration

VLAN Configuration

Near-End Site

2G data
3G data
3G OAM
MW OAM

Remark
1600
1800
2000

VLAN Configuration

Far-End Site

2G data
3G data
3G OAM
MW OAM

Remark
1600
1800
2000

7)

Browse Alarm Check


Check Item

Near-End Site

Current Alarm

OK NOK

History Alarm within 24hours

OK NOK

Check Item

Far-End Site

Current Alarm

OK NOK

History Alarm within 24hours

OK NOK

Remark

Remark

Optix RTN 900 Radio Transmission System v1.3


Normally the related NE should be no alarm, the alarm is affected from activity or not, case by case, please FM
escalate to MS BO for more query.

8)

NE Visibility on NMS System

Check Item
NE Visibility on NMS System

Near-End Site
OK NOK (*)

Remark

Check Item
NE Visibility on NMS System

Far-End Site
OK NOK (*)

Remark

9)

MW Link Performance Statistic

Check Item
MW Link Performance Statistic

Near-End Site
OK NOK (*)

Remark

Check Item
MW Link Performance Statistic

Far-End Site
OK NOK (*)

Remark

10) Inventory Software License


Check Item
Inventory Software License

Near-End Site
OK NOK (*)

Remark

Check Item
Inventory Software License

Far-End Site
OK NOK (*)

Remark

(*) Screenshot from NMS system should available as attachment

Optix RTN 900 Radio Transmission System v1.3


11) MW Capture

(Near-End Site)
Configuration Check
BINANGUN

Receive Power Level Result


BINANGUN

Interference Check
BINANGUN

Optix RTN 900 Radio Transmission System v1.3

Cross connection Service Configuration


BINANGUN

Ethernet Interface
BINANGUN

Optix RTN 900 Radio Transmission System v1.3

Ethernet Service Configuration


BINANGUN

Browse Alarm Check


BINANGUN

Optix RTN 900 Radio Transmission System v1.3

NE Visibility on NMS System


BINANGUN
(Data from NMS)
MW Link Performance Statistic
BINANGUN

Inventory Software License


BINANGUN

Optix RTN 900 Radio Transmission System v1.3

(Far-End Site)
Configuration Check
ADIPALA

Optix RTN 900 Radio Transmission System v1.3

Receive Power Level Result


ADIPALA

Interference Check
ADIPALA

Optix RTN 900 Radio Transmission System v1.3

Cross connection Service Configuration


ADIPALA

Ethernet Interface
ADIPALA

Optix RTN 900 Radio Transmission System v1.3

Ethernet Service Configuration


ADIPALA

Browse Alarm Check


ADIPALA

Optix RTN 900 Radio Transmission System v1.3

NE Visibility on NMS System


ADIPALA
(Data from NMS)
MW Link Performance Statistic
ADIPALA

Inventory Software License


ADIPALA

Optix RTN 900 Radio Transmission System v1.3

Optix RTN 900 Radio Transmission System v1.3

Ping Test
2G_BINANGUN

3G BINANGUN

Optix RTN 900 Radio Transmission System v1.3

OM BINANGUN

Ethernet Throughput Test


BINANGUN

Optix RTN 900 Radio Transmission System v1.3

ADIPALA

Ite

OptiX RTN 900 FATP Punch List


Link ID

14CLP022 14CLP004

Link Name

BINANGUN - ADIPALA

Description

Severity

Responsible

Supervisor

PT. Huawei Tech Investment


Representative

Name: -------------------------------------------

Cosmetic

Minor

Major

m No.

Optix RTN 900 Radio Transmission System v1.3


Date to
be
cleared

Group*

Date
Cleared**

PT. Indosat
Representative

-----------------------------------------------------

Date:

Anda mungkin juga menyukai