www.NOV.com/GrantPrideco
(in)
(in)
(in)
(in)
(in)
(in)
80 % Inspection Class
Nominal Weight Designation
25.60
(ft) 31.9
Drill Pipe Approximate Length
(in) 3/32 Raised
SmoothEdge Height
(psi) 120,000
Tool Joint SMYS
Upset Type
IEU
(in) 5.125
Max Upset OD (DTE)
Friction Factor
1.0
5.000
0.500
X-95
Range2
XT50
6.625
3.750
10
15
Drill-Pipe Length
Best Estimates
(without Coating)
80 % Inspection Class
Applied Make-up
Torque
Max Tension
Operational
Torque (ft-lbs)
(lbs)
(ft-lbs)
Maximum MUT
46,100
Minimum MUT
38,600
Tension Only
Combined Loading
Tension Only
Combined Loading
0
42,300
525,300
298,300
0
33,500
525,300
398,200
Fluid Displacement
Fluid Displacement
Fluid Capacity
Fluid Capacity
Drift Size
29.32
0.45
(Bbls/ft) 0.0107
(gal/ft) 0.63
(Bbls/ft) 0.0150
(in) 3.625
XT50
6.625
Applied Make-up
Tension at Shoulder
Torque
Separation
(ft-lbs)
46,100
38,600
(ft-lbs)
(lbs)
(lbs)
Tensile Limited
1,066,100
SmoothEdge Height
(in)
(lbs)
3/32 Raised
6.812
1,658,000
28.27
0.43
0.0103
0.65
0.0154
(lbs/ft)
0.62
0.0149
OD X
(in)
3.750
Tension at Connection
Yield
(lbs)
ID
(in)
120,000
(psi)
876,500
1,078,000
(in)
(in)
6.406
6.066
6.066
76,900
1,078,000
(least accurate)
(gal/ft)
Nominal
(with Coating)
Connection Performance
Maximum Make-up Torque
Minimum Make-up Torque
Range2
(in)
6.625
1,440,200
6.066
826,700
Nominal
Assumed Slip Length
Transverse Load Factor (K)
(lbs)
(in)
470,000
(ft-lbs)
(ft-lbs)
(psi)
(psi)
(in)
(in)
(in)
(in^2)
(in^2)
(in^2)
(in^3)
(in^3)
5 (in) OD
80 % Inspection Class
372,900
(lbs)
X-95 )
Note: Slip Crushing: Slip crushing load is calculated with the Spiri-Reinhold equation from Why Does Drill Pipe
Fail in the Slip Area World Oil, 1959 for the slip length and transverse load factor shown and is for reference
only. Slip crushing is dependent on the slip design and condition, coefficient of friction, loading conditions, time in
slips, drill pipe OD and wall variation, and other factors. Consult with the slip manufacturer for additional
information.
16.5
4.2
Nominal
Pipe Tensile Strength
Pipe Torsional Strength
TJ/PipeBody Torsional Ratio
80% Pipe Torsional Strength
Burst
Collapse
Pipe OD
Wall Thickness
Nominal Pipe ID
Cross Sectional Area of Pipe Body
Cross Sectional Area of OD
Cross Sectional Area of ID
Section Modulus
Polar Section Modulus
(in)
Note: Elevator capacity based on assumed Elevator Bore, no wear factor, and contact stress of 110,100psi.
Note: A raised elevator OD increases elevator capacity without affecting make-up torque.
5.219
6.318
1,096,600
6.812
671,500
66,200
1.16
53,000
16,625
17,100
5.000
0.500
4.000
7.069
19.635
12.566
7.245
14.491
5 (in) OD
80 % Inspection Class
525,300
51,400
1.50
41,100
15,200
14,514
4.800
0.400
4.000
5.529
18.096
12.566
5.621
11.243
X-95 )
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully
responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied
warranty is intended. Drill pipe assembly properties are calculated based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear
conditions (remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance
ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the application. For API connections that have different pin and box IDs, tool joint ID refers to
the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
www.NOV.com/GrantPrideco/CustomerFeedback
XT50
80 % Inspection Class
Tool Joint OD
(in)
6.625
Tool Joint ID
Pipe Body OD
(in)
(in)
0
2,200
4,400
6,700
8,900
11,100
13,300
15,600
17,800
20,000
22,200
24,500
26,700
28,900
31,100
33,400
35,600
37,800
40,000
42,300
(lbs)
525,300
524,800
523,300
520,800
517,300
512,900
507,400
500,500
492,700
483,800
473,700
461,600
448,700
434,200
418,000
399,000
378,600
355,600
329,400
298,300
X-95
(ft-lbs)
Connection Max
Pipe Body
Max Tension Tension
(lbs)
3.750
Operationa Assembly
l Torque
Max Tension
(ft-lbs)
(lbs)
Pipe Body
Max Tension
(lbs)
(lbs)
(ft-lbs)
Connection
Max Tension
(lbs)
525,300
525,300
1,066,100
525,300
876,500
524,800
876,500
1,800
525,000
525,000
1,066,100
876,500
3,500
524,100
524,100
1,066,100
1,066,100
523,300
520,800
876,500
5,300
522,500
522,500
517,300
876,500
7,100
520,200
520,200
1,066,100
512,900
876,500
8,800
517,500
517,500
1,066,100
507,400
876,500
10,600
514,000
514,000
1,066,100
876,500
12,300
510,000
510,000
1,066,100
876,500
14,100
505,100
505,100
1,066,100
876,500
15,900
499,500
499,500
1,066,100
1,066,100
500,500
492,700
483,800
473,700
876,500
17,600
493,500
493,500
461,600
876,500
19,400
486,400
486,400
1,066,100
448,700
876,500
21,200
478,400
478,400
1,066,100
434,200
876,500
22,900
470,200
470,200
1,066,100
876,500
24,700
460,500
460,500
1,066,100
876,500
26,400
450,600
450,600
1,066,100
439,000
439,000
1,066,100
1,066,100
418,000
399,000
378,600
28,200
876,500
355,600
876,500
30,000
426,300
426,300
329,400
876,500
31,700
413,300
413,300
1,066,100
298,300
876,500
33,500
398,200
398,200
1,066,100
Connection
Make-up Torque Range
Make-up Torque
(ft-lbs)
Min MUT
Max MUT
38,600
39,400
40,300
41,100
41,900
42,800
43,600
44,400
45,300
46,100
Connection Max
Tension
(lbs)
1,066,100
1,067,400
1,041,800
1,019,000
996,200
970,600
947,800
925,000
899,300
876,500
Note: Recommended MUT should always be used when possible. If not possible, MUT should be as close to Recommended MUT as possible.
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
02-03-2014
XT50
Tool Joint OD
Connection
Wear
Tool
Joint OD
New OD
(in)
6.625
6.574
6.523
6.473
6.422
6.371
6.32
6.269
6.218
6.168
6.117
6.066
Worn OD
(in)
6.625
Tool Joint ID
(in)
3.750
Connection Max
Tension
Connection
Torsional
Strength (ft-lbs)
Max
MUT
76,900
76,900
76,900
76,900
76,900
75,000
72,300
69,600
67,000
64,400
61,800
59,300
46,100
46,100
46,100
46,100
46,100
45,000
43,400
41,800
40,200
38,600
37,100
35,600
(ft-lbs)
Connection Max
Tension
Min MUT
(lbs)
(lbs)
(ft-lbs)
876,500
871,700
866,800
861,700
856,300
880,200
916,800
952,800
988,000
1,022,600
1,036,000
995,600
38,400
1,060,600
38,400
1,066,300
38,400
1,072,300
38,400
1,077,400
38,400
1,070,700
37,500
1,067,900
36,100
1,036,500
34,800
1,007,700
33,500
978,900
32,200
949,600
30,900
905,100
29,600
827,800
Pipe Body
Combined Loading Table (Torque-Tension)
Pipe Body
Pipe Body OD
80 % Inspection Class
(in)
X-95
4,700
9,300
14,000
18,700
23,300
28,000
32,700
37,300
42,000
46,700
51,300
523,100
516,600
505,400
489,200
468,100
440,300
405,000
361,100
302,300
218,500
24,500
(ft-lbs)
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
02-03-2014